Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ibmSystemRaidTrap 1.3.6.1.4.1.2.6.159.1.1.200.1
 ibmSystemRaidControllerTable 1.3.6.1.4.1.2.6.159.1.1.200.2 no-access
The IBMPSG_RAIDController class represents a RAID Controller
     ibmSystemRaidControllerEntry 1.3.6.1.4.1.2.6.159.1.1.200.2.1 no-access
This class defines an entry for each IBMPSG_RAIDController instance. Each instance of the IBMPSG_RAIDController class contains status and descriptive information for each disk recognized by the Director SMART provider.
         ibmSystemRaidControllerKeyIndex 1.3.6.1.4.1.2.6.159.1.1.200.2.1.1 string read-only
The RAID controller table index number (controller1, controller2, etc.)
         ibmSystemRaidControllerControllerID 1.3.6.1.4.1.2.6.159.1.1.200.2.1.2 string read-only
The DeviceID that identifies the disk
         ibmSystemRaidControllerModel 1.3.6.1.4.1.2.6.159.1.1.200.2.1.3 string read-only
The model of the controller
         ibmSystemRaidControllerBIOSVersion 1.3.6.1.4.1.2.6.159.1.1.200.2.1.4 string read-only
The version of the controllers BIOS
         ibmSystemRaidControllerFirmwareVersion 1.3.6.1.4.1.2.6.159.1.1.200.2.1.5 string read-only
The version of the controllers firmwar
         ibmSystemRaidControllerDriverVersion 1.3.6.1.4.1.2.6.159.1.1.200.2.1.6 string read-only
The version of the controllers device driver
         ibmSystemRaidControllerManufacturer 1.3.6.1.4.1.2.6.159.1.1.200.2.1.7 string read-only
the manufacturer of the controller
         ibmSystemRaidControllerSlot 1.3.6.1.4.1.2.6.159.1.1.200.2.1.8 uint16 read-only
The slot number the controller resides in
         ibmSystemRaidControllerFRU 1.3.6.1.4.1.2.6.159.1.1.200.2.1.9 string read-only
The FRU number of the controller
         ibmSystemRaidControllerSerialNumber 1.3.6.1.4.1.2.6.159.1.1.200.2.1.10 string read-only
The controllers serial number
         ibmSystemRaidControllerInitiatorIDs 1.3.6.1.4.1.2.6.159.1.1.200.2.1.11 string read-only
Specifies the controllers initiator IDs using a comma as the delimiter
         ibmSystemRaidControllerStatus 1.3.6.1.4.1.2.6.159.1.1.200.2.1.12 string read-only
The current status of the controller
 ibmSystemRaidDiskDriveTable 1.3.6.1.4.1.2.6.159.1.1.200.3 no-access
The IBMPSG_RAIDDiskDrive class represents a RAID physical disk
     ibmSystemRaidDiskDriveEntry 1.3.6.1.4.1.2.6.159.1.1.200.3.1 no-access
This class defines an entry for each IBMPSG_RAIDDiskDrive instance. Each instance of the IBMPSG_RAIDDiskDrive class contains status and descriptive information for each disk attached to the RAID controller.
         ibmSystemRaidDiskDriveKeyIndex 1.3.6.1.4.1.2.6.159.1.1.200.3.1.1 string read-only
The Physical Disk Drive table index number (Disk Drive 0, Disk Drive 1, etc.)
         ibmSystemRaidDiskDriveDeviceID 1.3.6.1.4.1.2.6.159.1.1.200.3.1.2 string read-only
The device ID of the drive
         ibmSystemRaidDiskDriveDiskDriveID 1.3.6.1.4.1.2.6.159.1.1.200.3.1.3 string read-only
The target ID of the disk drive
         ibmSystemRaidDiskDriveControllerID 1.3.6.1.4.1.2.6.159.1.1.200.3.1.4 string read-only
The ID of the controller it is attached to
         ibmSystemRaidDiskDriveChannelID 1.3.6.1.4.1.2.6.159.1.1.200.3.1.5 string read-only
The channel on the controller the drive is attached to
         ibmSystemRaidDiskDriveFirmware 1.3.6.1.4.1.2.6.159.1.1.200.3.1.6 string read-only
The firmware revision of the drive
         ibmSystemRaidDiskDriveState 1.3.6.1.4.1.2.6.159.1.1.200.3.1.7 uint16 read-only
The current state of the physical drive. 0=Empty, 1=Standby, 4=Defunct Hot Spare, 5=Standby Hot Spare, 8=Defunct Disk Drive, 129=Ready, 133=Hot Spare, 137=Online, 139=Rebuild, 254=Reserved
         ibmSystemRaidDiskDriveStatus 1.3.6.1.4.1.2.6.159.1.1.200.3.1.8 string read-only
The status of the drive
 ibmSystemRaidLogicalDriveTable 1.3.6.1.4.1.2.6.159.1.1.200.4 no-access
The IBMPSG_RAIDLogicalDrive class represents a RAID Logical disk (Logical Drive 0, Logical Drive 1, etc.)
     ibmSystemRaidLogicalDriveEntry 1.3.6.1.4.1.2.6.159.1.1.200.4.1 no-access
This class defines an entry for each IBMPSG_RAIDLogicalDrive instance. Each instance of the IBMPSG_RAIDLogicalDrive class contains status and descriptive information for each RAID Logical disk.
         ibmSystemRaidLogicalDriveKeyIndex 1.3.6.1.4.1.2.6.159.1.1.200.4.1.1 string read-only
The Logical Disk Drive table index number (Logical Drive 0, Logical Drive 1, etc.)
         ibmSystemRaidLogicalDriveLogicalDriveID 1.3.6.1.4.1.2.6.159.1.1.200.4.1.2 string read-only
The ID of the logical drive
         ibmSystemRaidLogicalDriveControllerID 1.3.6.1.4.1.2.6.159.1.1.200.4.1.3 string read-only
The ID of the controller the logical drive belongs to
         ibmSystemRaidLogicalDriveArrayID 1.3.6.1.4.1.2.6.159.1.1.200.4.1.4 string read-only
The ID of the array that the logical drive belongs to
         ibmSystemRaidLogicalDriveRAIDLevel 1.3.6.1.4.1.2.6.159.1.1.200.4.1.5 string read-only
The RAID level of the logical drive (RAID 1, RAID 5, etc.)
         ibmSystemRaidLogicalDriveDataSpace 1.3.6.1.4.1.2.6.159.1.1.200.4.1.6 uint64 read-only
Size of the logical drive in megabytes
         ibmSystemRaidLogicalDriveParitySpace 1.3.6.1.4.1.2.6.159.1.1.200.4.1.7 uint64 read-only
Parity space of the logical drive in megabytes
         ibmSystemRaidLogicalDriveIsBlocked 1.3.6.1.4.1.2.6.159.1.1.200.4.1.8 boolean read-only
The logical drive is in a blocked state
         ibmSystemRaidLogicalDriveState 1.3.6.1.4.1.2.6.159.1.1.200.4.1.9 uint16 read-only
The current state of the logical drive. 0=Free, 2=Offline, 3=Okay, 4=Critical, 5=Logical Drive Migration, 6=System, 20=Critical Logical Drive Migration, 36=Critical System
         ibmSystemRaidLogicalDriveStatus 1.3.6.1.4.1.2.6.159.1.1.200.4.1.10 string read-only
The status of the logical drive
 ibmSystemRaidTrapInfo 1.3.6.1.4.1.2.6.159.1.1.200.5
     ibmSystemRaidTrapProviderName 1.3.6.1.4.1.2.6.159.1.1.200.5.1 string no-access
The CIM Provider Name
     ibmSystemRaidTrapEventID 1.3.6.1.4.1.2.6.159.1.1.200.5.2 string no-access
Event ID
     ibmSystemRaidTrapPerceivedSeverity 1.3.6.1.4.1.2.6.159.1.1.200.5.3 integer no-access
Severity of the event 0=Normal / OK 1=Warning 2=Critical
     ibmSystemRaidDescription 1.3.6.1.4.1.2.6.159.1.1.200.5.4 string no-access
The event message
     ibmSystemRaidTrapEventTime 1.3.6.1.4.1.2.6.159.1.1.200.5.5 string no-access
Time that the event occured
       ibmSystemRaidNoControllers 1.3.6.1.4.1.2.6.159.1.1.200.10.201
Informational: No controllers were found in this system.
       ibmSystemRaidControllerFail 1.3.6.1.4.1.2.6.159.1.1.200.10.202
Error: Commands not responding on Controller %d.
       ibmSystemRaidDeadBattery 1.3.6.1.4.1.2.6.159.1.1.200.10.203
Error: The battery-backup cache device on Controller %d needs a new battery.
       ibmSystemRaidDeadBatteryCache 1.3.6.1.4.1.2.6.159.1.1.200.10.204
Error: The battery-backup cache device on Controller %d is defective %d
       ibmSystemRaidPollingFail 1.3.6.1.4.1.2.6.159.1.1.200.10.205
Error: Background polling commands not responding on Controller %d %d
       ibmSystemRaidConfigFail 1.3.6.1.4.1.2.6.159.1.1.200.10.206
Error: Cannot read controller configuration.
       ibmSystemRaidControllerAdded 1.3.6.1.4.1.2.6.159.1.1.200.10.207
Informational: Controller %d has been added to the system.
       ibmSystemRaidControllerReplaced 1.3.6.1.4.1.2.6.159.1.1.200.10.208
Informational: Controller %d has been replaced in the system.
       ibmSystemRaidControllerFailover 1.3.6.1.4.1.2.6.159.1.1.200.10.209
Informational: Controller %d failover detected. Passive controller is now active.
       ibmSystemRaidControllerVersionMismatch 1.3.6.1.4.1.2.6.159.1.1.200.10.210
Warning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible.
       ibmSystemRaidControllerBatteryOvertemp 1.3.6.1.4.1.2.6.159.1.1.200.10.211
Warning: Controller %d battery has exceeded normal operating temperature.
       ibmSystemRAIDControllerBadStripes 1.3.6.1.4.1.2.6.159.1.1.200.10.215
Warning: One or more logical drives contain a bad stripe: Controller %d.
       ibmSystemRaidControllerBatteryTempNormal 1.3.6.1.4.1.2.6.159.1.1.200.10.216
Informational: Controller %d battery operating temperature is normal.
       ibmSystemRaidControllerStatusChange 1.3.6.1.4.1.2.6.159.1.1.200.10.217
The status of the controller changed
       ibmSystemRaidLogicalDriveCritical 1.3.6.1.4.1.2.6.159.1.1.200.10.301
Warning: Logical Drive %d is Critical on Controller %d.
       ibmSystemRaidLogicalDriveBlocked 1.3.6.1.4.1.2.6.159.1.1.200.10.302
Error: Logical Drive %d is Blocked on Controller %d.
       ibmSystemRaidLogicalDriveOffLine 1.3.6.1.4.1.2.6.159.1.1.200.10.303
Error: Logical Drive %d is Offline on Controller %d.
       ibmSystemRaidRebuildDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.304
Informational: Rebuilding Logical Drive %d on Controller %d.
       ibmSystemRaidRebuildComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.305
Informational: Rebuild complete on Logical Drive %d of Controller %d.
       ibmSystemRaidRebuildFail 1.3.6.1.4.1.2.6.159.1.1.200.10.306
Error: Rebuild failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidSyncDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.307
Informational: Synchronizing Logical Drive %d on Controller %d.
       ibmSystemRaidSyncComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.308
Informational: Synchronization complete on Logical Drive %d of Controller %d.
       ibmSystemRaidSyncFail 1.3.6.1.4.1.2.6.159.1.1.200.10.309
Error: Synchronization failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidMigrationDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.310
Informational: Migrating Logical Drive %d on Controller %d.
       ibmSystemRaidMigrationComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.311
Informational: Migration complete on Logical Drive %d of Controller %d.
       ibmSystemRaidMigrationFail 1.3.6.1.4.1.2.6.159.1.1.200.10.312
Error: Migration failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidCompressionDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.313
Informational: Compressing Logical Drive %d on Controller %d.
       ibmSystemRaidCompressionComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.314
Informational: Compression complete on Logical Drive %d of Controller %d.
       ibmSystemRaidcompressionFail 1.3.6.1.4.1.2.6.159.1.1.200.10.315
Error: Compression failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidDecompressionDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.316
Informational: Decompressing Logical Drive %d on Controller %d.
       ibmSystemRaidDecompressionComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.317
Informational: Decompression complete on Logical Drive %d of Controller %d.
       ibmSystemRaidDecompressionFail 1.3.6.1.4.1.2.6.159.1.1.200.10.318
Error: Decompression failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidFlashCopyDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.319
Informational: FlashCopying Logical Drive %d on Controller %d.
       ibmSystemRaidFlashCopyComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.320
Informational: FlashCopy complete on Logical Drive %d of Controller %d.
       ibmSystemRaidFlashCopyFail 1.3.6.1.4.1.2.6.159.1.1.200.10.321
Error: FlashCopy failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidArrayRebuildDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.322
Informational: Rebuilding Array %d on Controller %d.
       ibmSystemRaidArrayRebuildComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.323
Informational: Rebuild complete on Array %d of Controller %d.
       ibmSystemRaidArrayRebuildFail 1.3.6.1.4.1.2.6.159.1.1.200.10.324
Error: Rebuild failed on Array %d of Controller %d %d.
       ibmSystemRaidArraySyncDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.325
Informational: Synchronizing Array %d on Controller %d.
       ibmSystemRaidArraySyncComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.326
Informational: Synchronization complete on Array %d of Controller %d.
       ibmSystemRaidArraySyncFail 1.3.6.1.4.1.2.6.159.1.1.200.10.327
Error: Synchronization failed on Array %d of Controller %d %d.
       ibmSystemRaidArrayFlashCopyDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.328
Informational: FlashCopying Array %d on Controller %d.
       ibmSystemRaidArrayFlashCopyComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.329
Informational: FlashCopy complete on Array %d of Controller %d.
       ibmSystemRaidArrayFlashCopyFail 1.3.6.1.4.1.2.6.159.1.1.200.10.330
Error: FlashCopy failed on Array %d of Controller %d %d.
       ibmSystemRaidLogicalDriveUnblocked 1.3.6.1.4.1.2.6.159.1.1.200.10.331
Informational: Logical Drive %d is unblocked on Controller %d.
       ibmSystemRaidCompactionDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.332
Informational: Compacting Logical Drive %d on Controller %d.
       ibmSystemRaidCompactionComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.333
Informational: Compaction complete on Logical Drive %d of Controller %d.
       ibmSystemRaidCompactionFail 1.3.6.1.4.1.2.6.159.1.1.200.10.334
Error: Compaction failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidExpansionDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.335
Informational: Expanding Logical Drive %d on Controller %d.
       ibmSystemRaidExpansionComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.336
Informational: Expansion complete on Logical Drive %d of Controller %d.
       ibmSystemRaidExpansionFail 1.3.6.1.4.1.2.6.159.1.1.200.10.337
Error: Expansion failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidLogicalDriveCriticalPeriodic 1.3.6.1.4.1.2.6.159.1.1.200.10.338
Warning: Periodic scan found 1 or more critical logical drives on Controller %d.
       ibmSystemRaidCopyBackDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.339
Informational: Copy back in progress on Logical Drive %d on Controller %d.
       ibmSystemRaidCopyBackComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.340
Informational: Copy back complete on Logical Drive %d of Controller %d.
       ibmSystemRaidCopyBackFail 1.3.6.1.4.1.2.6.159.1.1.200.10.341
Error: Copy back failed on Logical Drive %d of Controller %d %d.
       ibmSystemRaidInitDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.342
Informational: Initialization in progress on Logical Drive %d on Controller %d.
       ibmSystemRaidInitComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.343
Informational: Initialization complete on Logical Drive %d of Controller %d.
       ibmSystemRaidInitFail 1.3.6.1.4.1.2.6.159.1.1.200.10.344
Error: Initialization failed on Logical Drive %d of Controller %d %d.
       ibmSystemRAIDLogicalDriveOK 1.3.6.1.4.1.2.6.159.1.1.200.10.345
Informational: Logical Drive %d of Controller %d is normal.
       ibmSystemRAIDLogicalDriveAdded 1.3.6.1.4.1.2.6.159.1.1.200.10.346
Informational: Added Logical Drive %d of Controller %d.
       ibmSystemRAIDLogicalDriveRemoved 1.3.6.1.4.1.2.6.159.1.1.200.10.347
Informational: Removed Logical Drive %d of Controller %d.
       ibmSystemRaidArrayFlashCopyStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.348
The flashcopy operation has stopped
       ibmSystemRaidArrayRebuildStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.349
The array rebuild operation has stopped
       ibmSystemRaidArrayStatusChange 1.3.6.1.4.1.2.6.159.1.1.200.10.350
The array status has changed
       ibmSystemRaidArraySyncStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.351
The array synchronization operation has stopped
       ibmSystemRaidCompactionStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.352
The compaction operation has stopped
       ibmSystemRaidCompressionStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.353
The compression operation has stopped
       ibmSystemRaidCopybackStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.354
The copyback operation has stopped
       ibmSystemRaidDecompressionStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.355
The decompression operation has stopped
       ibmSystemRaidExpansionStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.356
The expansion operation has stopped
       ibmSystemRaidFlashCopyStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.357
The flashcopy operation has stopped
       ibmSystemRaidInitStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.358
The initialiation operation has stopped
       ibmSystemRaidLogicalDriveStatusChange 1.3.6.1.4.1.2.6.159.1.1.200.10.359
The status of the locaical drive has changed
       ibmSystemRaidMigrationStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.360
The migration operation has stopped
       ibmSystemRaidRebuildStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.361
The rebuild operation has stopped
       ibmSystemRaidSyncStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.362
The synchroniation operation has stopped
       ibmSystemRaidDefunctDrive 1.3.6.1.4.1.2.6.159.1.1.200.10.401
Error: Defunct drive on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidPfaDrive 1.3.6.1.4.1.2.6.159.1.1.200.10.402
Warning: PFA drive on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDefunctReplaced 1.3.6.1.4.1.2.6.159.1.1.200.10.403
Informational: A drive is set to Hot-Spare on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDefunctDriveFru 1.3.6.1.4.1.2.6.159.1.1.200.10.404
Error: Defunct drive (FRU Part # %d} on controller %d, channel %d, Device ID %d.
       ibmSystemRaidPfaDriveFru 1.3.6.1.4.1.2.6.159.1.1.200.10.405
Warning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidUnsupportedDrive 1.3.6.1.4.1.2.6.159.1.1.200.10.406
Warning: Unsupported physical drive found on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveAdded 1.3.6.1.4.1.2.6.159.1.1.200.10.407
Informational: Drive added on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveRemoved 1.3.6.1.4.1.2.6.159.1.1.200.10.408
Informational: Drive removed on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveClearDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.409
Informational: Clear in progress on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveClearComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.410
Informational: Clear complete on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveClearFail 1.3.6.1.4.1.2.6.159.1.1.200.10.411
Error: Clear failed on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveSyncDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.412
Informational: Synchronization in progress on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveSyncComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.413
Informational: Synchronization complete on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveSyncFail 1.3.6.1.4.1.2.6.159.1.1.200.10.414
Error: Synchronization failed on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveVerifyDetected 1.3.6.1.4.1.2.6.159.1.1.200.10.415
Informational: Verify in progress on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveVerifyComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.416
Informational: Verify complete on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveVerifyFail 1.3.6.1.4.1.2.6.159.1.1.200.10.417
Error: Verify failed on Controller %d, Channel %d, Device ID %d.
       ibmSystemRaidDriveClearStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.418
The drive clear operation has stopped
       ibmSystemRaidDriveSecureEraseStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.419
The secure erase operation has stopped
       ibmSystemRaidDriveStatusChange 1.3.6.1.4.1.2.6.159.1.1.200.10.420
The drive status has changed
       ibmSystemRaidDriveSyncStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.421
The sychronization operation has stopped
       ibmSystemRaidDriveVerifyStopped 1.3.6.1.4.1.2.6.159.1.1.200.10.422
The verify operation has stopped
       ibmSystemRaidSpareCreated 1.3.6.1.4.1.2.6.159.1.1.200.10.423
ibmSystemRaidSpareCreated
       ibmSystemRaidSpareDeleted 1.3.6.1.4.1.2.6.159.1.1.200.10.424
ibmSystemRaidSpareDeleted
       ibmSystemRaidEnclosureOK 1.3.6.1.4.1.2.6.159.1.1.200.10.501
Informational: Enclosure device responding on Controller %d, Channel %d.
       ibmSystemRaidEnclosureFail 1.3.6.1.4.1.2.6.159.1.1.200.10.502
Error: Enclosure device not responding on Controller %d, Channel %d.
       ibmSystemRaidFanOk 1.3.6.1.4.1.2.6.159.1.1.200.10.503
Informational: Enclosure fan %d on Controller %d, Channel %d is now operational.
       ibmSystemRaidFanFail 1.3.6.1.4.1.2.6.159.1.1.200.10.504
Error: Enclosure fan %d on Controller %d, Channel %d is malfunctioning.
       ibmSystemRaidFanInstalled 1.3.6.1.4.1.2.6.159.1.1.200.10.505
Informational: Enclosure fan %d on Controller %d, Channel %d has been installed.
       ibmSystemRaidFanRemoved 1.3.6.1.4.1.2.6.159.1.1.200.10.506
Warning: Enclosure fan %d on Controller %d, Channel %d has been removed.
       ibmSystemRaidTempOk 1.3.6.1.4.1.2.6.159.1.1.200.10.507
Error: Enclosure temperature is in normal range on Controller %d, Channel %d.
       ibmSystemRaidTempFail 1.3.6.1.4.1.2.6.159.1.1.200.10.508
Error: Enclosure temperature is out of normal range on Controller %d, Channel %d.
       ibmSystemRaidPowerSupplyOk 1.3.6.1.4.1.2.6.159.1.1.200.10.509
Informational: Enclosure power supply %d on Controller %d, Channel %d is now operational.
       ibmSystemRaidPowerSupplyFail 1.3.6.1.4.1.2.6.159.1.1.200.10.510
Error: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning.
       ibmSystemRaidPowerSupplyInstalled 1.3.6.1.4.1.2.6.159.1.1.200.10.511
Informational: Enclosure power supply %d on Controller %d, Channel %d has been installed.
       ibmSystemRaidPowerSupplyRemoved 1.3.6.1.4.1.2.6.159.1.1.200.10.512
Warning: Enclosure power supply %d on Controller %d, Channel %d has been removed.
       ibmSystemRaidTestTrap 1.3.6.1.4.1.2.6.159.1.1.200.10.601
Informational: This is a test trap.
       ibmSystemRaidLsiPDFail 1.3.6.1.4.1.2.6.159.1.1.200.10.1000
A physical drive has failed in a RAID configuration
       ibmSystemRaidLsiPDPartOfLDFail 1.3.6.1.4.1.2.6.159.1.1.200.10.1003
A physical drive has failed in a logical drive
       ibmSystemRaidLsiPDPartOfLDAdd 1.3.6.1.4.1.2.6.159.1.1.200.10.1004
A drive has been added to a RAID configuration
       ibmSystemRaidLsiHSPartOfLD 1.3.6.1.4.1.2.6.159.1.1.200.10.1005
ibmSystemRaidLsiHSPartOfLD
       ibmSystemRaidLsiHSFail 1.3.6.1.4.1.2.6.159.1.1.200.10.1007
A hot spare drive has failed in a RAID configuration
       ibmSystemRaidLsiPDHS 1.3.6.1.4.1.2.6.159.1.1.200.10.1008
A physical drive has been made a hot spare in the RAID configuration
       ibmSystemRaidLsiLDOffline 1.3.6.1.4.1.2.6.159.1.1.200.10.1009
A logical drive is in the offline state
       ibmSystemRaidLsiLDDegraded 1.3.6.1.4.1.2.6.159.1.1.200.10.1011
A logical drive has been degraded in a RAID configuration
       ibmSystemRaidLsiLDOptimal 1.3.6.1.4.1.2.6.159.1.1.200.10.1012
A logical drive is functioning correctly
       ibmSystemRaidLsiSMARTError 1.3.6.1.4.1.2.6.159.1.1.200.10.1013
A PFA has been detected on a drive in the RAID configuration
       ibmSystemRaidLsiRbldStart 1.3.6.1.4.1.2.6.159.1.1.200.10.1015
A RAID rebuild operation is in progress on an array in the RAID configuration
       ibmSystemRaidLsiRbldComplete 1.3.6.1.4.1.2.6.159.1.1.200.10.1016
A RAID rebuild operation has completed on an array in the RAID configuration
       ibmSystemRaidLsiRbldFail 1.3.6.1.4.1.2.6.159.1.1.200.10.1017
A RAID rebuild operation has failed on an array in the RAID configuration