Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ibmSystemTemperatureSensorTable 1.3.6.1.4.1.2.6.159.1.1.80.1 no-access
The IBMPSG_TemperatureSensor class represents an IBM managed Temperature Sensor.
     ibmSystemTemperatureSensorEntry 1.3.6.1.4.1.2.6.159.1.1.80.1.1 no-access
A sequence of temperature sensor entries
         ibmSystemTemperatureSensorKeyIndex 1.3.6.1.4.1.2.6.159.1.1.80.1.1.1 string read-only
The index used by this table
         ibmSystemTemperatureSensorCurrentReading 1.3.6.1.4.1.2.6.159.1.1.80.1.1.2 sint32 read-only
The current Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorNominalReading 1.3.6.1.4.1.2.6.159.1.1.80.1.1.3 sint32 read-only
The nominal Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorNormalMax 1.3.6.1.4.1.2.6.159.1.1.80.1.1.4 sint32 read-only
The normal maximum Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorNormalMin 1.3.6.1.4.1.2.6.159.1.1.80.1.1.5 sint32 read-only
The normal minimum Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorMaxReadable 1.3.6.1.4.1.2.6.159.1.1.80.1.1.6 sint32 read-only
The maximum readable Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorMinReadable 1.3.6.1.4.1.2.6.159.1.1.80.1.1.7 sint32 read-only
The minimum readalbe Celcius temperature reading for this sensor
         ibmSystemTemperatureSensorResolution 1.3.6.1.4.1.2.6.159.1.1.80.1.1.8 uint32 read-only
The resolution in Celcius of the temperature reading for this sensor
         ibmSystemTemperatureSensorTolerance 1.3.6.1.4.1.2.6.159.1.1.80.1.1.9 sint32 read-only
The tolerance in Celcius of the temperature reading for this sensor
         ibmSystemTemperatureSensorAccuracy 1.3.6.1.4.1.2.6.159.1.1.80.1.1.10 sint32 read-only
The degree of accuracy in Celcius of the temperature reading for this sensor
         ibmSystemTemperatureSensorLowerThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.1.1.11 sint32 read-only
The lower non-critical threshold in Celcius for this sensor
         ibmSystemTemperatureSensorUpperThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.1.1.12 sint32 read-only
The upper non-critical threshold in Celcius for this sensor
         ibmSystemTemperatureSensorLowerThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.1.1.13 sint32 read-only
The lower critical threshold in Celcius for this sensor
         ibmSystemTemperatureSensorUpperThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.1.1.14 sint32 read-only
The upper critical threshold in Celcius for this sensor
         ibmSystemTemperatureSensorLowerThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.1.1.15 sint32 read-only
The lower fatal threshold in Celcius for this sensor
         ibmSystemTemperatureSensorUpperThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.1.1.16 sint32 read-only
The upper fatal threshold in Celcius for this sensor
         ibmSystemTemperatureSensorTempLocation 1.3.6.1.4.1.2.6.159.1.1.80.1.1.17 uint32 read-only
The current temperature sensor location
         ibmSystemTemperatureSensorEventsEnabled 1.3.6.1.4.1.2.6.159.1.1.80.1.1.18 boolean read-only
Event generation status [True | False]
         ibmSystemTemperatureSensorPollingInterval 1.3.6.1.4.1.2.6.159.1.1.80.1.1.19 uint64 read-only
Polling interval is measured in seconds. Value of zero indicates do it once and quit. Minimum polling interval is ten seconds.
         ibmSystemTemperatureSensorEventAutoClearEnabled 1.3.6.1.4.1.2.6.159.1.1.80.1.1.20 boolean read-only
False means that events are only generated on state changes. True means that events are generated on state changes and periodically when the object is in a non-normal state.
         ibmSystemTemperatureSensorStatus 1.3.6.1.4.1.2.6.159.1.1.80.1.1.21 string read-only
The Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are Error, Starting, Stopping and Service. The latter, Service, could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither OK nor in one of the other states. Ok = Normal Error = Critical
 ibmSystemVoltageSensorTable 1.3.6.1.4.1.2.6.159.1.1.80.2 no-access
The IBMPSG_VoltageSensor class represents an IBM managed voltage Sensor.
     ibmSystemVoltageSensorEntry 1.3.6.1.4.1.2.6.159.1.1.80.2.1 no-access
A sequence of voltage sensor readings
         ibmSystemVoltageSensorKeyIndex 1.3.6.1.4.1.2.6.159.1.1.80.2.1.1 string read-only
The index used by this table
         ibmSystemVoltageSensorCurrentReading 1.3.6.1.4.1.2.6.159.1.1.80.2.1.2 sint32 read-only
The current voltage reading for this sensor
         ibmSystemVoltageSensorNominalReading 1.3.6.1.4.1.2.6.159.1.1.80.2.1.3 sint32 read-only
The nominal voltage reading for this sensor
         ibmSystemVoltageSensorNormalMax 1.3.6.1.4.1.2.6.159.1.1.80.2.1.4 sint32 read-only
The normal maximum voltage reading for this sensor
         ibmSystemVoltageSensorNormalMin 1.3.6.1.4.1.2.6.159.1.1.80.2.1.5 sint32 read-only
The normal minimum voltage reading for this sensor
         ibmSystemVoltageSensorMaxReadable 1.3.6.1.4.1.2.6.159.1.1.80.2.1.6 sint32 read-only
The maximum voltage reading for this sensor
         ibmSystemVoltageSensorMinReadable 1.3.6.1.4.1.2.6.159.1.1.80.2.1.7 sint32 read-only
The minimum voltage reading for this sensor
         ibmSystemVoltageSensorResolution 1.3.6.1.4.1.2.6.159.1.1.80.2.1.8 uint32 read-only
The resolution of the voltage reading for this sensor
         ibmSystemVoltageSensorTolerance 1.3.6.1.4.1.2.6.159.1.1.80.2.1.9 sint32 read-only
The tolerance of the voltage reading for this sensor
         ibmSystemVoltageSensorAccuracy 1.3.6.1.4.1.2.6.159.1.1.80.2.1.10 sint32 read-only
The accuracy of the voltage reading for this sensor
         ibmSystemVoltageSensorLowerThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.2.1.11 sint32 read-only
The non-critical lower threshold voltage reading for this sensor
         ibmSystemVoltageSensorUpperThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.2.1.12 sint32 read-only
The non-critical upper threshold voltage reading for this sensor
         ibmSystemVoltageSensorLowerThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.2.1.13 sint32 read-only
The critical lower threshold voltage reading for this sensor
         ibmSystemVoltageSensorUpperThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.2.1.14 sint32 read-only
The non-critical upper threshold voltage reading for this sensor
         ibmSystemVoltageSensorLowerThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.2.1.15 sint32 read-only
The fatal lower threshold voltage reading for this sensor
         ibmSystemVoltageSensorUpperThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.2.1.16 sint32 read-only
The fatal upper threshold voltage reading for this sensor
         ibmSystemVoltageSensorVoltageType 1.3.6.1.4.1.2.6.159.1.1.80.2.1.17 uint32 read-only
The Voltage Description
         ibmSystemVoltageSensorEventsEnabled 1.3.6.1.4.1.2.6.159.1.1.80.2.1.18 boolean read-only
Event generation status. [True | False]
         ibmSystemVoltageSensorPollingInterval 1.3.6.1.4.1.2.6.159.1.1.80.2.1.19 uint64 read-only
Polling interval is measured in seconds. Value of zero indicates do it once and quit. Minimum polling interval is ten seconds.
         ibmSystemVoltageSensorEventAutoClearEnabled 1.3.6.1.4.1.2.6.159.1.1.80.2.1.20 boolean read-only
False means that events are only generated on state changes. True means that events are generated on state changes and periodically when the object is in a non-normal state. [True | False]
         ibmSystemVoltageSensorStatus 1.3.6.1.4.1.2.6.159.1.1.80.2.1.21 string read-only
The Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are Error, Starting, Stopping and Service. The latter, Service, could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither OK nor in one of the other states. OK = Normal Error = Critical
 ibmSystemFanTable 1.3.6.1.4.1.2.6.159.1.1.80.3 no-access
The IBMPSG_Fan class represents an IBM managed fan sensor.
     ibmSystemFanEntry 1.3.6.1.4.1.2.6.159.1.1.80.3.1 no-access
A sequence of fan sensor readings
         ibmSystemFanKeyIndex 1.3.6.1.4.1.2.6.159.1.1.80.3.1.1 string read-only
The index used by this table
         ibmSystemFanVariableSpeed 1.3.6.1.4.1.2.6.159.1.1.80.3.1.2 boolean read-only
States if this fan supports variable speeds [True | False]
         ibmSystemFanDesiredSpeed 1.3.6.1.4.1.2.6.159.1.1.80.3.1.3 string read-only
The desired speed in revolutions per minute for this fan
         ibmSystemFanActiveCooling 1.3.6.1.4.1.2.6.159.1.1.80.3.1.4 boolean read-only
States if this fan supports active cooling [True | False]
         ibmSystemFanFanType 1.3.6.1.4.1.2.6.159.1.1.80.3.1.5 uint32 read-only
The current fan type.
         ibmSystemFanEventsEnabled 1.3.6.1.4.1.2.6.159.1.1.80.3.1.6 boolean read-only
Event generation status. [True | False]
         ibmSystemFanPollingInterval 1.3.6.1.4.1.2.6.159.1.1.80.3.1.7 uint64 read-only
Polling interval is measured in seconds. Value of zero indicates do it once and quit. Minimum polling interval is ten seconds.
         ibmSystemFanEventAutoClearEnabled 1.3.6.1.4.1.2.6.159.1.1.80.3.1.8 boolean read-only
False means that events are only generated on state changes. True means that events are generated on state changes and periodically when the object is in a non-normal state.
         ibmSystemFanStatus 1.3.6.1.4.1.2.6.159.1.1.80.3.1.9 string read-only
The Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are Error, Starting, Stopping and Service. The latter, Service, could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither OK nor in one of the other states. OK = Normal Error = Critical
 ibmSystemSystemEnclosureTable 1.3.6.1.4.1.2.6.159.1.1.80.4 no-access
The IBMPSG_SystemEnclosure class represents an IBM chassis sensor.
     ibmSystemSystemEnclosureEntry 1.3.6.1.4.1.2.6.159.1.1.80.4.1 no-access
A sequence of enclosure readings
         ibmSystemSystemEnclosureKeyIndex 1.3.6.1.4.1.2.6.159.1.1.80.4.1.1 string read-only
The index used by this table
         ibmSystemSystemEnclosureIntrusionStatus 1.3.6.1.4.1.2.6.159.1.1.80.4.1.2 uint32 read-only
The intrusion status
         ibmSystemSystemEnclosureIntrusionType 1.3.6.1.4.1.2.6.159.1.1.80.4.1.3 uint32 read-only
The intrusion type
         ibmSystemSystemEnclosureEventsEnabled 1.3.6.1.4.1.2.6.159.1.1.80.4.1.4 boolean read-only
Event generation enabled status. [True | False]
         ibmSystemSystemEnclosurePollingInterval 1.3.6.1.4.1.2.6.159.1.1.80.4.1.5 uint64 read-only
Polling interval is measured in seconds. Value of zero indicates do it once and quit. Minimum polling interval is ten seconds.
         ibmSystemSystemEnclosureDockingStatus 1.3.6.1.4.1.2.6.159.1.1.80.4.1.6 uint16 read-only
This defines whether system is docked or not
         ibmSystemSystemEnclosureACLineStatus 1.3.6.1.4.1.2.6.159.1.1.80.4.1.7 uint16 read-only
This group defines status information about the AC line in the notebook
         ibmSystemSystemEnclosureEventAutoClearEnabled 1.3.6.1.4.1.2.6.159.1.1.80.4.1.8 boolean read-only
False means that events are only generated on state changes. True means that events are generated on state changes and periodically when the object is in a non-normal state. [True | False]
         ibmSystemSystemEnclosureStatus 1.3.6.1.4.1.2.6.159.1.1.80.4.1.9 string read-only
The Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are Error, Starting, Stopping and Service. The latter, Service, could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither OK nor in one of the other states. OK = Normal Error = Critical
 ibmSystemTachometerTable 1.3.6.1.4.1.2.6.159.1.1.80.5 no-access
The IBMPSG_Tachometer class represents an IBM managed Fan speed Sensor.
     ibmSystemTachometerEntry 1.3.6.1.4.1.2.6.159.1.1.80.5.1 no-access
A sequence of fan enclosure readings
         ibmSystemTachometerKeyIndex 1.3.6.1.4.1.2.6.159.1.1.80.5.1.1 string read-only
The index used by this table
         ibmSystemTachometerCurrentReading 1.3.6.1.4.1.2.6.159.1.1.80.5.1.2 sint32 read-only
The current fan reading in revolutions per minute for this sensor
         ibmSystemTachometerNominalReading 1.3.6.1.4.1.2.6.159.1.1.80.5.1.3 sint32 read-only
The nominal fan reading in revolutions per minute for this sensor
         ibmSystemTachometerNormalMax 1.3.6.1.4.1.2.6.159.1.1.80.5.1.4 sint32 read-only
The normal maximum fan reading in revolutions per minute for this sensor
         ibmSystemTachometerNormalMin 1.3.6.1.4.1.2.6.159.1.1.80.5.1.5 sint32 read-only
The normal minimum fan reading in revolutions per minute for this sensor
         ibmSystemTachometerMaxReadable 1.3.6.1.4.1.2.6.159.1.1.80.5.1.6 sint32 read-only
The maximum readable fan reading in revolutions per minute for this sensor
         ibmSystemTachometerMinReadable 1.3.6.1.4.1.2.6.159.1.1.80.5.1.7 sint32 read-only
The minimum readable fan reading in revolutions per minute for this sensor
         ibmSystemTachometerResolution 1.3.6.1.4.1.2.6.159.1.1.80.5.1.8 uint32 read-only
The resolution of this fan reading in revolutions per minute for this sensor
         ibmSystemTachometerTolerance 1.3.6.1.4.1.2.6.159.1.1.80.5.1.9 sint32 read-only
The tolerance of this fan reading in revolutions per minute for this sensor
         ibmSystemTachometerLowerThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.5.1.10 sint32 read-only
The non-critical lower threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerUpperThresholdNonCritical 1.3.6.1.4.1.2.6.159.1.1.80.5.1.11 sint32 read-only
The non-critical upper threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerLowerThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.5.1.12 sint32 read-only
The critical lower threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerUpperThresholdCritical 1.3.6.1.4.1.2.6.159.1.1.80.5.1.13 sint32 read-only
The critical upper threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerLowerThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.5.1.14 sint32 read-only
The fatal lower threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerUpperThresholdFatal 1.3.6.1.4.1.2.6.159.1.1.80.5.1.15 sint32 read-only
The fatal upper threshold fan reading in revolutions per minute for this sensor
         ibmSystemTachometerFanDescrip 1.3.6.1.4.1.2.6.159.1.1.80.5.1.16 uint32 read-only
The Fan Description.
         ibmSystemTachometerFanType 1.3.6.1.4.1.2.6.159.1.1.80.5.1.17 uint32 read-only
The current fan type.
         ibmSystemTachometerEventsEnabled 1.3.6.1.4.1.2.6.159.1.1.80.5.1.18 boolean read-only
Event generation status.
         ibmSystemTachometerEventAutoClearEnabled 1.3.6.1.4.1.2.6.159.1.1.80.5.1.19 boolean read-only
False means that events are only generated on state changes. True means that events are generated on state changes and periodically when the object is in a non-normal state.
         ibmSystemTachometerStatus 1.3.6.1.4.1.2.6.159.1.1.80.5.1.20 string read-only
The Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are Error, Starting, Stopping and Service. The latter, Service, could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither OK nor in one of the other states. OK = Normal Error = Critical