IBM-Director-Alert-MIB: View SNMP OID List / Download MIB
VENDOR: IBM
Home | MIB: IBM-Director-Alert-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
ibm | 1.3.6.1.4.1.2 | |||
ibmProd | 1.3.6.1.4.1.2.6 | |||
director | 1.3.6.1.4.1.2.6.159 | |||
directorTraps | 1.3.6.1.4.1.2.6.159.201 |
This MIB is for use with the Event Action Plan Builder of IBM Director. |
||
directorFamily | 1.3.6.1.4.1.2.6.159.201.1 | |||
topology | 1.3.6.1.4.1.2.6.159.201.1.1 | |||
online | 1.3.6.1.4.1.2.6.159.201.1.1.1 |
The managed object's state has changed to online. |
||
offline | 1.3.6.1.4.1.2.6.159.201.1.1.2 |
The managed object's state has changed to offline. |
||
create | 1.3.6.1.4.1.2.6.159.201.1.1.3 |
The managed object has been created. |
||
change | 1.3.6.1.4.1.2.6.159.201.1.1.4 |
The managed object has changed. |
||
destroy | 1.3.6.1.4.1.2.6.159.201.1.1.5 |
The managed object has been destroyed. |
||
directorAgent | 1.3.6.1.4.1.2.6.159.201.1.2 | |||
processMonitor | 1.3.6.1.4.1.2.6.159.201.1.2.1 |
The process monitor threshold has generated an event. |
||
cpuMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.2 | |||
cpuUtilization | 1.3.6.1.4.1.2.6.159.201.1.2.2.1 |
The CPU utilization monitor threshold has generated an event. |
||
processCount | 1.3.6.1.4.1.2.6.159.201.1.2.2.2 |
The process count monitor threshold has generated an event. |
||
diskMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.3 | |||
driveSpaceUsed | 1.3.6.1.4.1.2.6.159.201.1.2.3.1 |
The drive space used monitor threshold has generated an event. |
||
driveSpaceUsedPercent | 1.3.6.1.4.1.2.6.159.201.1.2.3.2 |
The percentage of drive space used monitor threshold has generated an event. |
||
driveSpaceRemaining | 1.3.6.1.4.1.2.6.159.201.1.2.3.3 |
The drive space remaining monitor threshold has generated an event. |
||
driveWorkload | 1.3.6.1.4.1.2.6.159.201.1.2.3.4 |
The drive workload monitor threshold has generated an event. |
||
memoryMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.4 | |||
lockedMemory | 1.3.6.1.4.1.2.6.159.201.1.2.4.1 |
The locked memory monitor threshold has generated an event. |
||
memoryUsage | 1.3.6.1.4.1.2.6.159.201.1.2.4.2 |
The memory usage monitor threshold has generated an event. |
||
nicMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.5 | |||
ntPerfMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.6 | |||
totalPrivilegedTimePercent | 1.3.6.1.4.1.2.6.159.201.1.2.6.1 |
The percentage of total privileged time monitor threshold has generated an event. |
||
fileReadOperationsPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.6.2 |
The files read per second monitor threshold has generated an event. |
||
tcpipMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.7 | |||
udpPacketsSentPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.1 |
A threshold event for the number of UDP packets sent per second. |
||
udpPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.2 |
A threshold event for the number of UDP packets received per second. |
||
ipPacketsSentPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.3 |
A threshold event for the number of IP packets sent per second. |
||
ipPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.4 |
A threshold event for the number of IP packets received per second. |
||
ipErrorPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.5 |
A threshold event for the number of IP packets received with errors per second. |
||
tcpConnections | 1.3.6.1.4.1.2.6.159.201.1.2.7.6 |
A threshold event for the number of TCP connections. |
||
monitorEventDetails | 1.3.6.1.4.1.2.6.159.201.1.2.8 | |||
actualValue | 1.3.6.1.4.1.2.6.159.201.1.2.8.1 | snmpadminstring | read-only |
The actual value of the monitor. |
duration | 1.3.6.1.4.1.2.6.159.201.1.2.8.2 | displaystring | read-only |
The duration of this monitor. |
monitorResource | 1.3.6.1.4.1.2.6.159.201.1.2.8.3 | snmpadminstring | read-only |
The monitor resource. |
thresholdName | 1.3.6.1.4.1.2.6.159.201.1.2.8.4 | snmpadminstring | read-only |
The name of the monitor threshold. |
thresholdValue | 1.3.6.1.4.1.2.6.159.201.1.2.8.5 | snmpadminstring | read-only |
The value of the monitor threshold. |
test | 1.3.6.1.4.1.2.6.159.201.1.3 | |||
action | 1.3.6.1.4.1.2.6.159.201.1.3.1 |
The test action event. An internally generated event for the purpose of testing the action configuration. |
||
console | 1.3.6.1.4.1.2.6.159.201.1.4 | |||
consoleEventDetails | 1.3.6.1.4.1.2.6.159.201.1.4.1 | |||
userID | 1.3.6.1.4.1.2.6.159.201.1.4.1.1 | snmpadminstring | read-only |
The console user ID. |
address | 1.3.6.1.4.1.2.6.159.201.1.4.1.2 | snmpadminstring | read-only |
The console address. |
userName | 1.3.6.1.4.1.2.6.159.201.1.4.1.3 | snmpadminstring | read-only |
The console username. |
userDescription | 1.3.6.1.4.1.2.6.159.201.1.4.1.4 | snmpadminstring | read-only |
The console username's description. |
userLocale | 1.3.6.1.4.1.2.6.159.201.1.4.1.5 | snmpadminstring | read-only |
The console user's locale. |
logonFailure | 1.3.6.1.4.1.2.6.159.201.1.4.2 | |||
badPassword | 1.3.6.1.4.1.2.6.159.201.1.4.2.1 |
When attempting to logon to the console, a bad password was used. |
||
badUserID | 1.3.6.1.4.1.2.6.159.201.1.4.2.2 |
When attempting to logon to the console, a bad user ID was used. |
||
disabledUserID | 1.3.6.1.4.1.2.6.159.201.1.4.2.3 |
When attempting to logon to the console, a disabled user ID was used. |
||
downlevelConsole | 1.3.6.1.4.1.2.6.159.201.1.4.2.4 |
When attempting to logon to the console, a downlevel console was used. |
||
expiredPassword | 1.3.6.1.4.1.2.6.159.201.1.4.2.5 |
When attempting to logon to the console, an expired password was used. |
||
tooManyActiveIDs | 1.3.6.1.4.1.2.6.159.201.1.4.2.6 |
When attempting to logon to the console, too many IDs were active. |
||
tooManyActiveLogons | 1.3.6.1.4.1.2.6.159.201.1.4.2.7 |
When attempting to logon to the console, too many logons were active. |
||
uplevelConsole | 1.3.6.1.4.1.2.6.159.201.1.4.2.8 |
When attempting to logon to the console, an uplevel console was used. |
||
logoff | 1.3.6.1.4.1.2.6.159.201.1.4.3 |
A user has logged off the console. |
||
logon | 1.3.6.1.4.1.2.6.159.201.1.4.4 |
A user has logged on the console. |
||
generalEvent | 1.3.6.1.4.1.2.6.159.201.2 |
This is a IBM Director event converted into an SNMP trap. This trap is only used for events with no mapping. |
||
cimFamily | 1.3.6.1.4.1.2.6.159.201.3 | |||
windowsNTEventLog | 1.3.6.1.4.1.2.6.159.201.3.1 | |||
windowsNTEventLogEventDetails | 1.3.6.1.4.1.2.6.159.201.3.1.1 | |||
category | 1.3.6.1.4.1.2.6.159.201.3.1.1.1 | integer32 | read-only |
The Windows Event Log category. |
categoryString | 1.3.6.1.4.1.2.6.159.201.3.1.1.2 | snmpadminstring | read-only |
The Windows Event Log category string. |
computerName | 1.3.6.1.4.1.2.6.159.201.3.1.1.3 | snmpadminstring | read-only |
The computer name of the Windows Event Log event. |
data | 1.3.6.1.4.1.2.6.159.201.3.1.1.4 | octet string | read-only |
The Windows Event Log data for the event. |
eventLogCode | 1.3.6.1.4.1.2.6.159.201.3.1.1.5 | integer32 | read-only |
The Windows Event Log numeric event ID. |
eventLogIdentifier | 1.3.6.1.4.1.2.6.159.201.3.1.1.6 | displaystring | read-only |
The Windows Event Log numeric event identifier. |
eventLogType | 1.3.6.1.4.1.2.6.159.201.3.1.1.7 | integer32 | read-only |
The Windows Event Log numeric event type. |
insertionStrings | 1.3.6.1.4.1.2.6.159.201.3.1.1.8 | snmpadminstring | read-only |
The Windows Event Log insertion strings. |
logFile | 1.3.6.1.4.1.2.6.159.201.3.1.1.9 | snmpadminstring | read-only |
The Windows Event Log file name. |
message | 1.3.6.1.4.1.2.6.159.201.3.1.1.10 | snmpadminstring | read-only |
The Windows Event Log message string. |
recordNumber | 1.3.6.1.4.1.2.6.159.201.3.1.1.11 | displaystring | read-only |
The Windows Event Log record number. |
sourceName | 1.3.6.1.4.1.2.6.159.201.3.1.1.12 | snmpadminstring | read-only |
The Windows Event Log source name. |
type | 1.3.6.1.4.1.2.6.159.201.3.1.1.13 | snmpadminstring | read-only |
The Windows Event Log type. |
user | 1.3.6.1.4.1.2.6.159.201.3.1.1.14 | snmpadminstring | read-only |
The Windows Event Log user. |
applicationLog | 1.3.6.1.4.1.2.6.159.201.3.1.2 |
The Windows NT application event log has changed. |
||
securityLog | 1.3.6.1.4.1.2.6.159.201.3.1.3 |
The Windows NT application security log has changed. |
||
systemLog | 1.3.6.1.4.1.2.6.159.201.3.1.4 |
The Windows NT application system log has changed. |
||
windowsNTService | 1.3.6.1.4.1.2.6.159.201.3.2 | |||
windowsNTServiceEventDetails | 1.3.6.1.4.1.2.6.159.201.3.2.1 | |||
acceptPause | 1.3.6.1.4.1.2.6.159.201.3.2.1.1 | truthvalue | read-only |
Whether this service accepts the pause state change. |
acceptStop | 1.3.6.1.4.1.2.6.159.201.3.2.1.2 | truthvalue | read-only |
Whether this service accepts the stop state change. |
caption | 1.3.6.1.4.1.2.6.159.201.3.2.1.3 | snmpadminstring | read-only |
The caption string for this service. |
checkPoint | 1.3.6.1.4.1.2.6.159.201.3.2.1.4 | displaystring | read-only |
The service's check point. |
creationClassName | 1.3.6.1.4.1.2.6.159.201.3.2.1.5 | snmpadminstring | read-only |
The creation class name for the service. |
serviceDescription | 1.3.6.1.4.1.2.6.159.201.3.2.1.6 | snmpadminstring | read-only |
The description of the service. |
desktopInteract | 1.3.6.1.4.1.2.6.159.201.3.2.1.7 | truthvalue | read-only |
Whether the service interacts with the desktop. |
displayName | 1.3.6.1.4.1.2.6.159.201.3.2.1.8 | snmpadminstring | read-only |
The displayable name for the service. |
errorControl | 1.3.6.1.4.1.2.6.159.201.3.2.1.9 | snmpadminstring | read-only |
The error control value for the service. |
exitCode | 1.3.6.1.4.1.2.6.159.201.3.2.1.10 | displaystring | read-only |
The exit code of the process for the service. |
name | 1.3.6.1.4.1.2.6.159.201.3.2.1.11 | snmpadminstring | read-only |
The name of the service. |
pathName | 1.3.6.1.4.1.2.6.159.201.3.2.1.12 | snmpadminstring | read-only |
The path name for the service. |
processId | 1.3.6.1.4.1.2.6.159.201.3.2.1.13 | displaystring | read-only |
The process ID of the running service. |
serviceSpecificExitCode | 1.3.6.1.4.1.2.6.159.201.3.2.1.14 | displaystring | read-only |
The specific exit code for the service. |
serviceType | 1.3.6.1.4.1.2.6.159.201.3.2.1.15 | snmpadminstring | read-only |
The type of service. |
startMode | 1.3.6.1.4.1.2.6.159.201.3.2.1.16 | snmpadminstring | read-only |
The start mode for the service. |
startName | 1.3.6.1.4.1.2.6.159.201.3.2.1.17 | snmpadminstring | read-only |
The start name for the service. |
started | 1.3.6.1.4.1.2.6.159.201.3.2.1.18 | truthvalue | read-only |
Whether this service has started. |
serviceState | 1.3.6.1.4.1.2.6.159.201.3.2.1.19 | snmpadminstring | read-only |
The state of the service. |
status | 1.3.6.1.4.1.2.6.159.201.3.2.1.20 | snmpadminstring | read-only |
The status of the service. |
systemCreationClassName | 1.3.6.1.4.1.2.6.159.201.3.2.1.21 | snmpadminstring | read-only |
The system creation class name for the service. |
systemName | 1.3.6.1.4.1.2.6.159.201.3.2.1.22 | snmpadminstring | read-only |
The system name for the service. |
tagId | 1.3.6.1.4.1.2.6.159.201.3.2.1.23 | displaystring | read-only |
The tag ID of the service. |
waitHint | 1.3.6.1.4.1.2.6.159.201.3.2.1.24 | displaystring | read-only |
The value of the wait hint for the service. |
startedService | 1.3.6.1.4.1.2.6.159.201.3.2.2 |
A Windows NT service has started. |
||
stoppedService | 1.3.6.1.4.1.2.6.159.201.3.2.3 |
A Windows NT service has stopped. |
||
windowsRegistry | 1.3.6.1.4.1.2.6.159.201.3.3 | |||
windowsRegistryEventDetails | 1.3.6.1.4.1.2.6.159.201.3.3.1 | |||
hive | 1.3.6.1.4.1.2.6.159.201.3.3.1.1 | snmpadminstring | read-only |
The Windows Registry hive for this event. |
rootPath | 1.3.6.1.4.1.2.6.159.201.3.3.1.2 | snmpadminstring | read-only |
The Windows Registry root path for this event. |
securityDescriptor | 1.3.6.1.4.1.2.6.159.201.3.3.1.3 | octet string | read-only |
The Windows Registry security descriptor for this event. |
timeCreated | 1.3.6.1.4.1.2.6.159.201.3.3.1.4 | snmpadminstring | read-only |
The time this item was created in the Windows Registry. |
softwareTreeChanged | 1.3.6.1.4.1.2.6.159.201.3.3.2 |
The Windows software tree section of the registry has changed. |
||
systemTreeChanged | 1.3.6.1.4.1.2.6.159.201.3.3.3 |
The Windows system tree section of the registry has changed. |
||
mpaFamily | 1.3.6.1.4.1.2.6.159.201.4 | |||
mpaEventDetails | 1.3.6.1.4.1.2.6.159.201.4.1 | |||
alertCode | 1.3.6.1.4.1.2.6.159.201.4.1.1 | integer32 | read-only |
The alert code. |
busId | 1.3.6.1.4.1.2.6.159.201.4.1.2 | integer32 | read-only |
The bus ID. |
componentId | 1.3.6.1.4.1.2.6.159.201.4.1.3 | snmpadminstring | read-only |
The component ID. |
firmwareCode | 1.3.6.1.4.1.2.6.159.201.4.1.4 | octet string | read-only |
The firmware identification code. |
ipAddress1 | 1.3.6.1.4.1.2.6.159.201.4.1.5 | octet string | read-only |
The first IP address. |
ipAddress2 | 1.3.6.1.4.1.2.6.159.201.4.1.6 | octet string | read-only |
The second IP address. |
issue | 1.3.6.1.4.1.2.6.159.201.4.1.7 | snmpadminstring | read-only |
The issue for the event. |
powerDomain | 1.3.6.1.4.1.2.6.159.201.4.1.8 | integer32 | read-only |
The domain of the power supply. |
reason | 1.3.6.1.4.1.2.6.159.201.4.1.9 | snmpadminstring | read-only |
The reason for the event. |
scsiId | 1.3.6.1.4.1.2.6.159.201.4.1.10 | integer32 | read-only |
The ID of the SCSI device. |
side | 1.3.6.1.4.1.2.6.159.201.4.1.11 | snmpadminstring | read-only |
The side in which the event occured. |
newState | 1.3.6.1.4.1.2.6.159.201.4.1.12 | snmpadminstring | read-only |
The new state. |
temperatureSensor | 1.3.6.1.4.1.2.6.159.201.4.1.13 | snmpadminstring | read-only |
The current temperature. |
threshold | 1.3.6.1.4.1.2.6.159.201.4.1.14 | snmpadminstring | read-only |
The threshold for the event. |
universalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.15 | octet string | read-only |
The universal unique ID. |
senderUniversalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.16 | octet string | read-only |
The universal unique ID of the sender. |
sourceUniversalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.17 | octet string | read-only |
The universal unique ID of the source. |
unitNumber | 1.3.6.1.4.1.2.6.159.201.4.1.18 | integer32 | read-only |
The unit number. |
voltageSensor | 1.3.6.1.4.1.2.6.159.201.4.1.19 | snmpadminstring | read-only |
The voltage sensor. |
component | 1.3.6.1.4.1.2.6.159.201.4.2 | |||
bladeServer | 1.3.6.1.4.1.2.6.159.201.4.2.1 | |||
coD | 1.3.6.1.4.1.2.6.159.201.4.2.1.1 | |||
codEnabled | 1.3.6.1.4.1.2.6.159.201.4.2.1.1.1 |
The CoD has been enabled. |
||
bladeServerCommunication | 1.3.6.1.4.1.2.6.159.201.4.2.1.2 |
Communication with a blade has been established. |
||
bladeServerInserted | 1.3.6.1.4.1.2.6.159.201.4.2.1.3 |
A blade has been inserted. |
||
bladeServerRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.1.4 |
A blade has been removed. |
||
bus | 1.3.6.1.4.1.2.6.159.201.4.2.2 | |||
busCommunication | 1.3.6.1.4.1.2.6.159.201.4.2.2.1 |
Communication with a bus has been established. |
||
chassis | 1.3.6.1.4.1.2.6.159.201.4.2.3 | |||
chassisConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.3.1 |
The blade chassis configuration has changed. |
||
chassisFailed | 1.3.6.1.4.1.2.6.159.201.4.2.3.2 |
The blade chassis has failed. |
||
dasd | 1.3.6.1.4.1.2.6.159.201.4.2.4 | |||
dasdFailed | 1.3.6.1.4.1.2.6.159.201.4.2.4.1 |
a direct access storage device has failed. |
||
dasdInserted | 1.3.6.1.4.1.2.6.159.201.4.2.4.2 |
A direct access storage device has been inserted. |
||
dasdRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.4.3 |
A direct access storage device has been removed. |
||
memory | 1.3.6.1.4.1.2.6.159.201.4.2.5 | |||
memoryFailed | 1.3.6.1.4.1.2.6.159.201.4.2.5.1 |
Some memory has failed. |
||
componentFan | 1.3.6.1.4.1.2.6.159.201.4.2.6 | |||
componentFanFailed | 1.3.6.1.4.1.2.6.159.201.4.2.6.1 |
A fan has failed. |
||
componentFanInserted | 1.3.6.1.4.1.2.6.159.201.4.2.6.2 |
A fan has been inserted. |
||
componentFanPfa | 1.3.6.1.4.1.2.6.159.201.4.2.6.3 |
The fan component has generated a PFA. |
||
componentFanRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.6.4 |
A fan has been removed. |
||
hardwareInformation | 1.3.6.1.4.1.2.6.159.201.4.2.7 | |||
hardwareCrashDump | 1.3.6.1.4.1.2.6.159.201.4.2.7.1 | |||
hardwareCrashDumpAborted | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.1 |
A hardware crash dump was aborted. |
||
hardwareCrashDumpCompleted | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.2 |
A hardware crash dump has completed. |
||
hardwareCrashDumpInitiated | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.3 |
A hardware crash dump has been initiated. |
||
ioModule | 1.3.6.1.4.1.2.6.159.201.4.2.8 | |||
ioModuleConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.8.1 |
An I/O module's configuration has changed. |
||
ioModuleFailed | 1.3.6.1.4.1.2.6.159.201.4.2.8.2 |
An I/O module has failed. |
||
ioModuleInserted | 1.3.6.1.4.1.2.6.159.201.4.2.8.3 |
An I/O module has been inserted. |
||
ioModulePost | 1.3.6.1.4.1.2.6.159.201.4.2.8.4 |
An I/O module has past POST. |
||
ioModulePower | 1.3.6.1.4.1.2.6.159.201.4.2.8.5 | |||
ioModulePowerOn | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.1 |
An I/O module has been powered on. |
||
ioModulePowerOff | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.2 |
An I/O module has been powered off. |
||
ioModuleRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.8.6 |
An I/O module is a redundancy. |
||
ioModuleRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.8.7 |
An I/O module has been removed. |
||
kvm | 1.3.6.1.4.1.2.6.159.201.4.2.9 | |||
kvmOwner | 1.3.6.1.4.1.2.6.159.201.4.2.9.1 |
The KVM owner has changed. |
||
osImage | 1.3.6.1.4.1.2.6.159.201.4.2.10 | |||
osImageCrashDump | 1.3.6.1.4.1.2.6.159.201.4.2.10.1 | |||
osImageCrashDumpAborted | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.1 |
The operating system image crash dump was aborted. |
||
osImageCrashDumpCompleted | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.2 |
The operating system image crash dump has completed. |
||
osImageCrashDumpInitiated | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.3 |
The operating system image crash dump has been initiated. |
||
componentPfa | 1.3.6.1.4.1.2.6.159.201.4.2.11 |
A component has generated a PFA. |
||
powerSubsystem | 1.3.6.1.4.1.2.6.159.201.4.2.12 | |||
powerSubsystemLowFuel | 1.3.6.1.4.1.2.6.159.201.4.2.12.1 |
The power subsystem indicates low fuel. |
||
powerSubsystemOverCurrent | 1.3.6.1.4.1.2.6.159.201.4.2.12.2 |
The power subsystem indicates over current. |
||
powerSubsystemOverPower | 1.3.6.1.4.1.2.6.159.201.4.2.12.3 |
The power subsystem indicates over power. |
||
powerSubsystemRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.12.4 |
The power subsystem indicates a redundancy. |
||
powerSupply | 1.3.6.1.4.1.2.6.159.201.4.2.13 | |||
powerSupplyFailed | 1.3.6.1.4.1.2.6.159.201.4.2.13.1 |
A power supply has failed. |
||
powerSupplyInserted | 1.3.6.1.4.1.2.6.159.201.4.2.13.2 |
A power supply has been inserted. |
||
powerSupplyRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.13.3 |
A power supply has been removed. |
||
server | 1.3.6.1.4.1.2.6.159.201.4.2.14 | |||
serverPower | 1.3.6.1.4.1.2.6.159.201.4.2.14.1 | |||
serverPowerOff | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.1 |
The server has powered off. |
||
serverPowerOn | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.2 |
The server has powered on. |
||
serverPowerState | 1.3.6.1.4.1.2.6.159.201.4.2.14.2 |
The server's power state has changed. |
||
serviceProcessor | 1.3.6.1.4.1.2.6.159.201.4.2.15 | |||
serviceProcessorActive | 1.3.6.1.4.1.2.6.159.201.4.2.15.1 |
A service processor is now active. |
||
serviceProcessorConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.15.2 |
A service processor configuration has changed. |
||
serviceProcessorInserted | 1.3.6.1.4.1.2.6.159.201.4.2.15.3 |
A service processor has been inserted. |
||
serviceProcessorLog | 1.3.6.1.4.1.2.6.159.201.4.2.15.4 |
A service processor has generated a log. |
||
serviceProcessorNetworkStack | 1.3.6.1.4.1.2.6.159.201.4.2.15.5 |
A service processor network stack has changed. |
||
serviceProcessorRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.15.6 |
A service processor detected a redundancy. |
||
serviceProcessorRemoteLogin | 1.3.6.1.4.1.2.6.159.201.4.2.15.7 |
A remove login was made into the service processor. |
||
serviceProcessorRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.15.8 |
A service processor has been removed. |
||
serviceProcessorRestart | 1.3.6.1.4.1.2.6.159.201.4.2.15.9 |
A service processor has been restarted. |
||
serviceProcessorTest | 1.3.6.1.4.1.2.6.159.201.4.2.15.10 |
A service processor test was issued. |
||
smpExpansionModule | 1.3.6.1.4.1.2.6.159.201.4.2.16 | |||
smpExpansionModuleDisabled | 1.3.6.1.4.1.2.6.159.201.4.2.16.1 |
An SMP expansion module has been disabled. |
||
usb | 1.3.6.1.4.1.2.6.159.201.4.2.17 | |||
usbInserted | 1.3.6.1.4.1.2.6.159.201.4.2.17.1 |
A USB device has been inserted. |
||
usbOwner | 1.3.6.1.4.1.2.6.159.201.4.2.17.2 |
A USB device owner has changed. |
||
usbRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.17.3 |
A USB device has been removed. |
||
vrm | 1.3.6.1.4.1.2.6.159.201.4.2.18 | |||
vrmFailed | 1.3.6.1.4.1.2.6.159.201.4.2.18.1 |
The VRM has failed. |
||
critical | 1.3.6.1.4.1.2.6.159.201.4.3 | |||
hardDiskDrive | 1.3.6.1.4.1.2.6.159.201.4.3.1 |
A hard disk drive is in critical state. |
||
multipleFanFailure | 1.3.6.1.4.1.2.6.159.201.4.3.2 |
Multiple fans have failed. |
||
powerFailure | 1.3.6.1.4.1.2.6.159.201.4.3.3 | |||
powerFailureEpow | 1.3.6.1.4.1.2.6.159.201.4.3.3.1 |
There was a critical power failure as a result of an EPOW. |
||
powerFailureFailed | 1.3.6.1.4.1.2.6.159.201.4.3.3.2 |
There was a critical power failure as a result of something failing. |
||
powerFailureRemoved | 1.3.6.1.4.1.2.6.159.201.4.3.3.3 |
There was a critical power failure as a result of something removed. |
||
criticalTamper | 1.3.6.1.4.1.2.6.159.201.4.3.4 |
Tampering with the system has caused a critical state. |
||
criticalTemperature | 1.3.6.1.4.1.2.6.159.201.4.3.5 | |||
criticalTemperatureAmbient | 1.3.6.1.4.1.2.6.159.201.4.3.5.1 |
The ambient temperature is in a critical state. |
||
criticalTemperaturePci | 1.3.6.1.4.1.2.6.159.201.4.3.5.2 |
The PCI temperature is in a critical state. |
||
criticalTemperaturePlanar | 1.3.6.1.4.1.2.6.159.201.4.3.5.3 |
The planar temperature is in a critical state. |
||
criticalVoltage | 1.3.6.1.4.1.2.6.159.201.4.3.6 | |||
criticalTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.1 | |||
criticalTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.1 |
A critical state of 12V high has been detected. |
||
criticalTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.2 |
A critical state of 12V low has been detected. |
||
criticalTwelveVoltsFaultA | 1.3.6.1.4.1.2.6.159.201.4.3.6.2 |
A critical state of 12V fault A has been detected. |
||
criticalTwelveVoltsFaultB | 1.3.6.1.4.1.2.6.159.201.4.3.6.3 |
A critical state of 12V fault B has been detected. |
||
criticalTwelveVoltsFaultC | 1.3.6.1.4.1.2.6.159.201.4.3.6.4 |
A critical state of 12V fault C has been detected. |
||
criticalTwelveVoltsFaultD | 1.3.6.1.4.1.2.6.159.201.4.3.6.5 |
A critical state of 12V fault D has been detected. |
||
criticalOneVolt | 1.3.6.1.4.1.2.6.159.201.4.3.6.6 | |||
criticalOneVoltHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.1 |
A critical state of 1V high has been detected. |
||
criticalOneVoltLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.2 |
A critical state of 1V low has been detected. |
||
criticalTwoVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.7 | |||
criticalTwoVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.1 |
A critical state of 2V high has been detected. |
||
criticalTwoVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.2 |
A critical state of 2V low has been detected. |
||
criticalThreeVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.8 | |||
criticalThreeVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.1 |
A critical state of 3V high has been detected. |
||
criticalThreeVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.2 |
A critical state of 3V low has been detected. |
||
criticalThreeVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.3.6.9 | |||
criticalThreeVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.1 |
A critical state of 3V high has been detected for the PCI. |
||
criticalThreeVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.2 |
A critical state of 3V low has been detected for the PCI. |
||
criticalThreeVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.3.6.10 | |||
criticalThreeVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.1 |
A critical state of 3V standby high has been detected. |
||
criticalThreeVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.2 |
A critical state of 3V standby low has been detected. |
||
criticalFiveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.11 | |||
criticalFiveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.1 |
A critical state of 5V high has been detected. |
||
criticalFiveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.2 |
A critical state of 5V low has been detected. |
||
criticalFiveVoltsFault | 1.3.6.1.4.1.2.6.159.201.4.3.6.12 | |||
criticalFiveVoltsFaultHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.1 |
A critical state of 5V fault high has been detected. |
||
criticalFiveVoltsFaultLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.2 |
A critical state of 5V fault low has been detected. |
||
criticalFiveVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.3.6.13 | |||
criticalFiveVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.1 |
A critical state of 5V high has been detected for the PCI. |
||
criticalFiveVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.2 |
A critical state of 5V low has been detected for the PCI. |
||
criticalFiveVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.3.6.14 | |||
criticalFiveVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.1 |
A critical state of 5V standby high has been detected. |
||
criticalFiveVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.2 |
A critical state of 5V standby low has been detected. |
||
criticalNTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.15 | |||
criticalNTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.1 |
A critical state of negative 12V high has been detected. |
||
criticalNTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.2 |
A critical state of negative 12V low has been detected. |
||
voltageRegulatorModuleFailure | 1.3.6.1.4.1.2.6.159.201.4.3.7 |
The voltage regulator module has failed. |
||
deployment | 1.3.6.1.4.1.2.6.159.201.4.4 | |||
deploymentBoot | 1.3.6.1.4.1.2.6.159.201.4.4.1 |
Deployment has generated a boot event. |
||
deploymentLoader | 1.3.6.1.4.1.2.6.159.201.4.4.2 |
Deployment has generated a loader event. |
||
deploymentOs | 1.3.6.1.4.1.2.6.159.201.4.4.3 |
Deployment has generated an operating system event. |
||
deploymentPost | 1.3.6.1.4.1.2.6.159.201.4.4.4 |
Deployment has generated a POST event. |
||
environmental | 1.3.6.1.4.1.2.6.159.201.4.5 | |||
environmentalTemperature | 1.3.6.1.4.1.2.6.159.201.4.5.1 |
The environmental temperature has changed. |
||
environmentalVoltage | 1.3.6.1.4.1.2.6.159.201.4.5.2 |
The environmental voltage has changed. |
||
nonCritical | 1.3.6.1.4.1.2.6.159.201.4.6 | |||
nonCriticalFan | 1.3.6.1.4.1.2.6.159.201.4.6.1 | |||
nonCriticalFanRemoved | 1.3.6.1.4.1.2.6.159.201.4.6.1.1 |
A fan has been removed. |
||
redundantPower | 1.3.6.1.4.1.2.6.159.201.4.6.2 |
The system is now running on redundant power. |
||
singleFanFailure | 1.3.6.1.4.1.2.6.159.201.4.6.3 |
A single fan has failed. |
||
nonCriticalTemperature | 1.3.6.1.4.1.2.6.159.201.4.6.4 | |||
nonCriticalTemperatureAmbient | 1.3.6.1.4.1.2.6.159.201.4.6.4.1 |
The ambient temperature is in a non critical state. |
||
nonCriticalTemperaturePci | 1.3.6.1.4.1.2.6.159.201.4.6.4.2 |
The PCI temperature is in a non critical state. |
||
nonCriticalTemperaturePlanar | 1.3.6.1.4.1.2.6.159.201.4.6.4.3 |
The planar temperature is in a non critical state. |
||
nonCriticalVoltage | 1.3.6.1.4.1.2.6.159.201.4.6.5 | |||
nonCriticalTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.1 | |||
nonCriticalTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.1 |
A non-critical state of 12V high has been detected. |
||
nonCriticalTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.2 |
A non-critical state of 12V low has been detected. |
||
nonCriticalOneVolt | 1.3.6.1.4.1.2.6.159.201.4.6.5.2 | |||
nonCriticalOneVoltHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.1 |
A non-critical state of 1V high has been detected. |
||
nonCriticalOneVoltLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.2 |
A non-critical state of 1V low has been detected. |
||
nonCriticalTwoVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.3 | |||
nonCriticalTwoVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.1 |
A non-critical state of 2V high has been detected. |
||
nonCriticalTwoVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.2 |
A non-critical state of 2V low has been detected. |
||
nonCriticalThreeVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.4 | |||
nonCriticalThreeVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.1 |
A non-critical state of 3V high has been detected. |
||
nonCriticalThreeVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.2 |
A non-critical state of 3V low has been detected. |
||
nonCriticalThreeVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.6.5.5 | |||
nonCriticalThreeVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.1 |
A non-critical state of 3V high has been detected for the PCI. |
||
nonCriticalThreeVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.2 |
A non-critical state of 3V low has been detected for the PCI. |
||
nonCriticalThreeVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.6.5.6 | |||
nonCriticalThreeVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.1 |
A non-critical state of 3V standby high has been detected. |
||
nonCriticalThreeVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.2 |
A non-critical state of 3V standby low has been detected. |
||
nonCriticalFiveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.7 | |||
nonCriticalFiveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.1 |
A non-critical state of 5V high has been detected. |
||
nonCriticalFiveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.2 |
A non-critical state of 5V low has been detected. |
||
nonCriticalFiveVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.6.5.8 | |||
nonCriticalFiveVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.1 |
A non-critical state of 5V high has been detected for the PCI. |
||
nonCriticalFiveVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.2 |
A non-critical state of 5V low has been detected for the PCI. |
||
nonCriticalFiveVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.6.5.9 | |||
nonCriticalFiveVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.1 |
A non-critical state of 5V standby high has been detected. |
||
nonCriticalFiveVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.2 |
A non-critical state of 5V standby low has been detected. |
||
nonCriticalNTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.10 | |||
nonCriticalNTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.1 |
A non-critical state of negative 12V high has been detected. |
||
nonCriticalNTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.2 |
A non-critical state of negative 12V low has been detected. |
||
platform | 1.3.6.1.4.1.2.6.159.201.4.7 | |||
scalableNode | 1.3.6.1.4.1.2.6.159.201.4.7.1 | |||
scalableNodeMode | 1.3.6.1.4.1.2.6.159.201.4.7.1.1 | |||
scalableNodeModeNullOrUnknown | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.1 |
The scalable node is in a null or unknown mode. |
||
scalableNodeModePrimary | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.2 |
The scalable node is in primary mode. |
||
scalableNodeModeSecondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.3 |
The scalable node is in secondary mode. |
||
scalableNodeModeStandalone | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.4 |
The scalable node is now in standalone mode. |
||
scalableNodeStandalone | 1.3.6.1.4.1.2.6.159.201.4.7.1.2 | |||
standaloneMode | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1 | |||
primary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.1 |
The scalable node is now in standalone primary mode. |
||
reset | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2 | |||
resetPrimary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.1 |
The scalable node is now in standalone primary reset mode. |
||
resetSecondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.2 |
The scalable node is now in standalone primary secondary mode. |
||
secondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.3 |
The scalable node is now in standalone secondary mode. |
||
scalablePartition | 1.3.6.1.4.1.2.6.159.201.4.7.2 | |||
scalablePartitionAlert | 1.3.6.1.4.1.2.6.159.201.4.7.2.1 |
The scalabel partition has generated an alert. |
||
scalablePartitionState | 1.3.6.1.4.1.2.6.159.201.4.7.2.2 | |||
scalablePartitionNullOrUnknown | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.1 |
The scalable partition state is 'null or unknown'. |
||
scalablePartitionPoweredOff | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.2 |
The scalable partition state is 'powered off'. |
||
scalablePartitionPoweringOn | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.3 |
The scalable partition state is 'powering on'. |
||
scalablePartitionResetting | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.4 |
The scalable partition state is 'resetting'. |
||
scalablePartitionShuttingDown | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.5 |
The scalable partition state is 'shutting down'. |
||
system | 1.3.6.1.4.1.2.6.159.201.4.8 | |||
bootFailure | 1.3.6.1.4.1.2.6.159.201.4.8.1 |
The system indicated a boot failure. |
||
fuelGauge | 1.3.6.1.4.1.2.6.159.201.4.8.2 | |||
fuelGaugeLowFuel | 1.3.6.1.4.1.2.6.159.201.4.8.2.1 |
The fuel gauge indicates low fuel. |
||
fuelGaugeNotRedundant | 1.3.6.1.4.1.2.6.159.201.4.8.2.2 |
The fuel gauge indicates not redundant. |
||
fuelGaugeOverCurrent | 1.3.6.1.4.1.2.6.159.201.4.8.2.3 |
The fuel gauge indicates over current. |
||
systemLoaderTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.3 |
The system loader has timed out. |
||
systemOsTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.4 |
The operating system has timed out. |
||
systemPfa | 1.3.6.1.4.1.2.6.159.201.4.8.5 | |||
fanSystemPfa | 1.3.6.1.4.1.2.6.159.201.4.8.5.1 |
The fan system has generated a PFA. |
||
systemPostTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.6 |
The POST has timed out. |
||
systemPowerOff | 1.3.6.1.4.1.2.6.159.201.4.8.7 |
The sytsem has powered off. |
||
systemPowerOn | 1.3.6.1.4.1.2.6.159.201.4.8.8 |
The sytsem has powered on. |
||
systemRedundantPower | 1.3.6.1.4.1.2.6.159.201.4.8.9 |
The system is running on redundant power. |
||
systemTamper | 1.3.6.1.4.1.2.6.159.201.4.8.10 |
The system has been tampered with. |
||
unknown | 1.3.6.1.4.1.2.6.159.201.4.9 |
The system is in an unknown state. |
||
petFamily | 1.3.6.1.4.1.2.6.159.201.5 | |||
petFamilyEventDetails | 1.3.6.1.4.1.2.6.159.201.5.1 | |||
allVariableBindings | 1.3.6.1.4.1.2.6.159.201.5.1.1 | octet string | read-only |
All of the variable bindings for this PET trap. |
entity | 1.3.6.1.4.1.2.6.159.201.5.1.2 | octet string | read-only |
The entity of this PET event. |
entityInstance | 1.3.6.1.4.1.2.6.159.201.5.1.3 | octet string | read-only |
The entity instance of this PET event. |
petEventData | 1.3.6.1.4.1.2.6.159.201.5.1.4 | octet string | read-only |
The event data of this PET event. |
petEventSeverity | 1.3.6.1.4.1.2.6.159.201.5.1.5 | octet string | read-only |
The severity of this PET event. |
petEventSourceType | 1.3.6.1.4.1.2.6.159.201.5.1.6 | octet string | read-only |
The source type of this PET event. |
petEventType | 1.3.6.1.4.1.2.6.159.201.5.1.7 | octet string | read-only |
The type of the PET event. |
guid | 1.3.6.1.4.1.2.6.159.201.5.1.8 | octet string | read-only |
The GUID for this PET event. |
languageCode | 1.3.6.1.4.1.2.6.159.201.5.1.9 | octet string | read-only |
The language code for this PET event. |
localTimeStamp | 1.3.6.1.4.1.2.6.159.201.5.1.10 | displaystring | read-only |
The local time stamp of this PET event. |
manufacturerId | 1.3.6.1.4.1.2.6.159.201.5.1.11 | displaystring | read-only |
The manufacturer ID for the source of the PET event. |
oemCustomField | 1.3.6.1.4.1.2.6.159.201.5.1.12 | octet string | read-only |
The value for the OEM customer field of this PET event. |
offset | 1.3.6.1.4.1.2.6.159.201.5.1.13 | octet string | read-only |
The offset for this PET event. |
sensorDevice | 1.3.6.1.4.1.2.6.159.201.5.1.14 | octet string | read-only |
The sensor device for this PET event. |
sensorNumber | 1.3.6.1.4.1.2.6.159.201.5.1.15 | octet string | read-only |
The sensor number for this PET event. |
sensorType | 1.3.6.1.4.1.2.6.159.201.5.1.16 | octet string | read-only |
The sensor type for this PET event. |
sequenceId | 1.3.6.1.4.1.2.6.159.201.5.1.17 | integer32 | read-only |
The sequence ID for this PET event. |
systemId | 1.3.6.1.4.1.2.6.159.201.5.1.18 | integer32 | read-only |
The system ID for this PET event. |
trapSourceType | 1.3.6.1.4.1.2.6.159.201.5.1.19 | octet string | read-only |
The trap source type for this PET event. |
utcOffset | 1.3.6.1.4.1.2.6.159.201.5.1.20 | integer32 | read-only |
The UTC offset for this PET event. |
petEnvironmental | 1.3.6.1.4.1.2.6.159.201.5.2 | |||
petEnvironmentalSensor | 1.3.6.1.4.1.2.6.159.201.5.2.1 | |||
sensorCaseIntrusion | 1.3.6.1.4.1.2.6.159.201.5.2.1.1 |
A sensor has detected a case intrusion. |
||
sensorCurrent | 1.3.6.1.4.1.2.6.159.201.5.2.1.2 |
A sensor has detected a current change. |
||
sensorFan | 1.3.6.1.4.1.2.6.159.201.5.2.1.3 |
A sensor has detected a fan change. |
||
sensorPowerSupply | 1.3.6.1.4.1.2.6.159.201.5.2.1.4 |
A sensor has detected a power supply change. |
||
sensorTemperature | 1.3.6.1.4.1.2.6.159.201.5.2.1.5 |
A sensor has detected a temperature change. |
||
sensorVoltage | 1.3.6.1.4.1.2.6.159.201.5.2.1.6 |
A sensor has detected a voltage change. |
||
firmware | 1.3.6.1.4.1.2.6.159.201.5.3 | |||
bios | 1.3.6.1.4.1.2.6.159.201.5.3.1 | |||
progress | 1.3.6.1.4.1.2.6.159.201.5.3.1.1 |
The progress of the BIOS has changed. |
||
hardware | 1.3.6.1.4.1.2.6.159.201.5.4 | |||
cableInterconnect | 1.3.6.1.4.1.2.6.159.201.5.4.1 |
The cable/interconnect hardware has generated an event. |
||
drivebay | 1.3.6.1.4.1.2.6.159.201.5.4.2 |
The monitor drivebay hardware has generated an event. |
||
moduleBoard | 1.3.6.1.4.1.2.6.159.201.5.4.3 |
The monitor module/board hardware has generated an event. |
||
monitorAsicIc | 1.3.6.1.4.1.2.6.159.201.5.4.4 |
The monitor ASIC/IC hardware has generated an event. |
||
network | 1.3.6.1.4.1.2.6.159.201.5.4.5 |
The network hardware has generated an event. |
||
watchdog1 | 1.3.6.1.4.1.2.6.159.201.5.4.6 |
The hardware has generated a watchdog 1 event. |
||
watchdog2 | 1.3.6.1.4.1.2.6.159.201.5.4.7 |
The hardware has generated a watchdog 2 event. |
||
petFamilySystem | 1.3.6.1.4.1.2.6.159.201.5.5 | |||
petFamilySystemOs | 1.3.6.1.4.1.2.6.159.201.5.5.1 | |||
petFamilySystemOsBoot | 1.3.6.1.4.1.2.6.159.201.5.5.1.1 |
The operating system on the host has booted. |
||
petFamilySystemOsOperation | 1.3.6.1.4.1.2.6.159.201.5.5.1.2 | |||
heartbeat | 1.3.6.1.4.1.2.6.159.201.5.5.1.2.1 |
The operating system has generated a heartbeat event. |
||
storageFamily | 1.3.6.1.4.1.2.6.159.201.6 | |||
serveRaidController | 1.3.6.1.4.1.2.6.159.201.6.1 | |||
physicalDrive | 1.3.6.1.4.1.2.6.159.201.6.1.1 | |||
vendorUnsupported | 1.3.6.1.4.1.2.6.159.201.6.1.1.1 |
The vendor for this physical drive is unsupported. |
||
state | 1.3.6.1.4.1.2.6.159.201.6.1.2 | |||
notFound | 1.3.6.1.4.1.2.6.159.201.6.1.2.1 |
No controllers were found in this system. |
||
directorTrapsConformance | 1.3.6.1.4.1.2.6.159.201.100 | |||
directorTrapsGroups | 1.3.6.1.4.1.2.6.159.201.100.1 | |||
directorTrapsGroup | 1.3.6.1.4.1.2.6.159.201.100.1.1 |
The objects group for objects defined in this module. |
||
directorNotificationsGroup | 1.3.6.1.4.1.2.6.159.201.100.1.2 |
The notification group for notifications defined in this module. |
||
directorTrapsCompliances | 1.3.6.1.4.1.2.6.159.201.100.2 | |||
directorTrapsCompliance | 1.3.6.1.4.1.2.6.159.201.100.2.1 |
The compliance statement for this module. |
||
description | 1.3.6.1.4.1.2.6.159.202 | |||
trapType | 1.3.6.1.4.1.2.6.159.202.1 | snmpadminstring | read-only |
The type of the event. |
trapSeverity | 1.3.6.1.4.1.2.6.159.202.2 | snmpadminstring | read-only |
The severity of the event. |
trapSenderName | 1.3.6.1.4.1.2.6.159.202.3 | snmpadminstring | read-only |
The system name from which the event was sent. |
trapManagedObjectName | 1.3.6.1.4.1.2.6.159.202.4 | snmpadminstring | read-only |
The system name for which the event was generated. |
trapText | 1.3.6.1.4.1.2.6.159.202.5 | snmpadminstring | read-only |
Text associated with the event. |
trapCategory | 1.3.6.1.4.1.2.6.159.202.6 | snmpadminstring | read-only |
The category of the event. |
details | 1.3.6.1.4.1.2.6.159.9696 | |||
char | 1.3.6.1.4.1.2.6.159.9696.1 | octet string | read-only |
Eight bit unsigned event detail. |
short | 1.3.6.1.4.1.2.6.159.9696.2 | integer32 | read-only |
Sixteen bit signed event detail. |
int | 1.3.6.1.4.1.2.6.159.9696.3 | integer32 | read-only |
Thirty-two bit signed event detail. |
long | 1.3.6.1.4.1.2.6.159.9696.4 | displaystring | read-only |
Sixty-four bit signed event detail. |
boolean | 1.3.6.1.4.1.2.6.159.9696.5 | truthvalue | read-only |
Thirty-two bit unsigned event detail. |
float | 1.3.6.1.4.1.2.6.159.9696.6 | displaystring | read-only |
Thirty-two bit decimal pointed event detail. |
double | 1.3.6.1.4.1.2.6.159.9696.7 | displaystring | read-only |
Sixty-four bit decimal pointed event detail. |
octet | 1.3.6.1.4.1.2.6.159.9696.8 | displaystring | read-only |
A string of bytes holding an event detail. |
string | 1.3.6.1.4.1.2.6.159.9696.9 | snmpadminstring | read-only |
A string of unicode chars (normal text) holding an event detail. |
dateTime | 1.3.6.1.4.1.2.6.159.9696.10 | displaystring | read-only |
Date and time since 1/1970 as an event detail. |
uniChar | 1.3.6.1.4.1.2.6.159.9696.11 | displaystring | read-only |
A unicode char holding an event detail. |
byte | 1.3.6.1.4.1.2.6.159.9696.12 | displaystring | read-only |
One byte holding an event detail. |