HW-IMAPV1NORTHBOUND-TRAP-MIB: View SNMP OID List / Download MIB
VENDOR: HUAWEI
Home | MIB: HW-IMAPV1NORTHBOUND-TRAP-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
huawei | 1.3.6.1.4.1.2011 | |||
products | 1.3.6.1.4.1.2011.2 | |||
hwNetManagement | 1.3.6.1.4.1.2011.2.15 | |||
hwNmAgent | 1.3.6.1.4.1.2011.2.15.1 | |||
hwNmFault | 1.3.6.1.4.1.2011.2.15.1.3 | |||
thirdNMSFaultFilter | 1.3.6.1.4.1.2011.2.15.1.3.5 | octet string | read-write |
This is to add the filter condition by the upper NMS the syntax is IP:Port:Alarm Level Example : 127.0.0.1:161:0011 In this IP is 127.0.0.1 Port is 161 Alarm Level - Minor and warning should not be sent as the bit is set for them |
hwNmNorthboundEvent | 1.3.6.1.4.1.2011.2.15.1.7 | |||
hwNmNorthboundEventInfo | 1.3.6.1.4.1.2011.2.15.1.7.1 | |||
hwNmNorthboundNEName | 1.3.6.1.4.1.2011.2.15.1.7.1.1 | octet string | read-only |
The name of network element,string (255) |
hwNmNorthboundNEType | 1.3.6.1.4.1.2011.2.15.1.7.1.2 | octet string | read-only |
Device type of element,string(64) |
hwNmNorthboundObjectInstance | 1.3.6.1.4.1.2011.2.15.1.7.1.3 | octet string | read-only |
Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255) |
hwNmNorthboundEventType | 1.3.6.1.4.1.2011.2.15.1.7.1.4 | octet string | read-only |
Event type of Network management,string(64) |
hwNmNorthboundEventTime | 1.3.6.1.4.1.2011.2.15.1.7.1.5 | octet string | read-only |
Alarm generate time,string(64),format: 2003/03/14 00:00:00 |
hwNmNorthboundProbableCause | 1.3.6.1.4.1.2011.2.15.1.7.1.6 | octet string | read-only |
Reason of Probable caused alarm, string(64) |
hwNmNorthboundSeverity | 1.3.6.1.4.1.2011.2.15.1.7.1.7 | octet string | read-only |
Level of Alarm, string(64) |
hwNmNorthboundEventDetail | 1.3.6.1.4.1.2011.2.15.1.7.1.8 | octet string | read-only |
Alarm ID and detail information, format: ID+detail infomation, string(255) |
hwNmNorthboundAdditionalInfo | 1.3.6.1.4.1.2011.2.15.1.7.1.9 | octet string | read-only |
Additional infomation of device, such as Country, City and so on, string(255) |
hwNmNorthboundFaultFlag | 1.3.6.1.4.1.2011.2.15.1.7.1.10 | octet string | read-only |
The flag of the fault.Show whether the alarm is an event ,a fault alarm or a recovery alarm. |
hwNmNorthboundFaultFunction | 1.3.6.1.4.1.2011.2.15.1.7.1.11 | octet string | read-only |
The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Processerror','UNKNOWN_FUC_TYPE' |
hwNmNorthboundDeviceIP | 1.3.6.1.4.1.2011.2.15.1.7.1.12 | ipaddress | read-only |
The IP address of the device |
hwNmNorthboundSerialNo | 1.3.6.1.4.1.2011.2.15.1.7.1.13 | integer | read-only |
The serial number of alarm. |
hwNmNorthboundProbableRepair | 1.3.6.1.4.1.2011.2.15.1.7.1.14 | octet string | read-only |
The probable repair advice of the alarm. |
hwNmNorthboundResourceIDs | 1.3.6.1.4.1.2011.2.15.1.7.1.15 | octet string | read-only |
The ID of the resource. |
hwNmNorthboundsAdditionalVB1 | 1.3.6.1.4.1.2011.2.15.1.7.1.16 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB2 | 1.3.6.1.4.1.2011.2.15.1.7.1.17 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB3 | 1.3.6.1.4.1.2011.2.15.1.7.1.18 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB4 | 1.3.6.1.4.1.2011.2.15.1.7.1.19 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB5 | 1.3.6.1.4.1.2011.2.15.1.7.1.20 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB6 | 1.3.6.1.4.1.2011.2.15.1.7.1.21 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB7 | 1.3.6.1.4.1.2011.2.15.1.7.1.22 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundsAdditionalVB8 | 1.3.6.1.4.1.2011.2.15.1.7.1.23 | octet string | read-only |
Addtional information of the alarm |
hwNmNorthboundEventName | 1.3.6.1.4.1.2011.2.15.1.7.1.24 | octet string | read-only |
The name of event,string (255) |
hwNmNorthboundEventKeepAliveInfo | 1.3.6.1.4.1.2011.2.15.1.7.2 | |||
hwNmNorthboundEventSynchronization | 1.3.6.1.4.1.2011.2.15.1.7.7 | |||
hwNmNorthboundEventSynchronizationStart | 1.3.6.1.4.1.2011.2.15.1.7.7.1 | |||
hwNmNorthboundEventSynchronizationQueryResult | 1.3.6.1.4.1.2011.2.15.1.7.7.2 | |||
hwNmNorthboundEventSynchronizationEnd | 1.3.6.1.4.1.2011.2.15.1.7.7.3 | |||
hwNmNorthboundEventSynchronizationEndStatus | 1.3.6.1.4.1.2011.2.15.1.7.7.3.1 | integer | read-only |
It shows the result of alarm synchronization. 1 means the alarm synchronization successfully ended. 2 means the alarm synchronization is stopped by the NMS's command. 3 means some error occured during the alarm synchronization. Enumeration: 'normalEnd': 1, 'stopped': 2, 'error': 3. |
hwNmNorthboundEventSynchronizationEndStatusDetail | 1.3.6.1.4.1.2011.2.15.1.7.7.3.2 | octet string | read-only |
The detail description of the alarm synchronization end status. |
hwNmNorthboundEventSynchronizationCommandStart | 1.3.6.1.4.1.2011.2.15.1.7.7.4 | octet string | read-write |
This node is to be set to start the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will send alarm synchronization result to the IP and port specified. If there is already an running alarm synchronization for that IP and port,it will return a commit fail error. |
hwNmNorthboundEventSynchronizationCommandStop | 1.3.6.1.4.1.2011.2.15.1.7.7.5 | octet string | read-write |
This node is to be set to stop the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will stop alarm synchronization for the IP and port specified. If there is no such an running alarm synchronization for that IP and port,it will return a commit fail error. |
hwNmNorthboundEventSynchronizationStartNotify | 1.3.6.1.4.1.2011.2.15.1.7.7.10.9 |
Notification indicates the beginning of alarm synchronization. |
||
hwNmNorthboundEventSynchronizationQueryResultNotify | 1.3.6.1.4.1.2011.2.15.1.7.7.20.10 |
Notification carries the query result of alarm synchronization. |
||
hwNmNorthboundEventSynchronizationEndNotify | 1.3.6.1.4.1.2011.2.15.1.7.7.30.11 |
Notification indicates the end of alarm synchronization. |
||
hwNmNorthboundEventNotify | 1.3.6.1.4.1.2011.2.15.1.7.10.1 |
Notification for real-time alarm. |
||
hwNmNorthboundEventNotifyCritical | 1.3.6.1.4.1.2011.2.15.1.7.10.3 |
Notification for real-time alarm whose level is Critical. |
||
hwNmNorthboundEventNotifyMajor | 1.3.6.1.4.1.2011.2.15.1.7.10.4 |
Notification for real-time alarm whose level is Major. |
||
hwNmNorthboundEventNotifyMinor | 1.3.6.1.4.1.2011.2.15.1.7.10.5 |
Notification for real-time alarm whose level is Minor. |
||
hwNmNorthboundEventNotifyWarning | 1.3.6.1.4.1.2011.2.15.1.7.10.6 |
Notification for real-time alarm whose level is Warning. |
||
hwNmNorthboundEventNotifyIndefinitely | 1.3.6.1.4.1.2011.2.15.1.7.10.7 |
Notification for real-time alarm whose level is Indefinitely. |
||
hwNmNorthboundEventNotifyUnknownSeverity | 1.3.6.1.4.1.2011.2.15.1.7.10.8 |
Notification for real-time alarm whose level is UnknownSeverity. |
||
hwNmNorthboundEventKeepAlive | 1.3.6.1.4.1.2011.2.15.1.7.20.2 |
Notification for keep alive traps. |