HUAWEI-R2-MIB: View SNMP OID List / Download MIB
VENDOR: HUAWEI
Home | MIB: HUAWEI-R2-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hwR2Protocol | 1.3.6.1.4.1.2011.6.108 |
This MIB module defines MIB objects which provides R2 attribute management. |
||
hwR2Objects | 1.3.6.1.4.1.2011.6.108.1 | |||
hwR2ProfileTable | 1.3.6.1.4.1.2011.6.108.1.1 | no-access |
R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this table is hwR2ProfileIndex |
|
1.3.6.1.4.1.2011.6.108.1.1.1 | no-access |
R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this entry is hwR2ProfileIndex |
||
hwR2ProfileIndex | 1.3.6.1.4.1.2011.6.108.1.1.1.1 | integer32 | no-access |
R2 signaling profile index |
hwSignalName | 1.3.6.1.4.1.2011.6.108.1.1.1.2 | octet string | read-write |
R2 signaling profile name |
hwSignalType | 1.3.6.1.4.1.2011.6.108.1.1.1.3 | integer32 | read-write |
R2 signaling type |
hwR2SignalProfileRowStatus | 1.3.6.1.4.1.2011.6.108.1.1.1.4 | rowstatus | read-write |
Row status of R2 signaling profile |
hwRegisterSignalAttributeTable | 1.3.6.1.4.1.2011.6.108.1.2 | no-access |
R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this table is hwRegisterSignalIndex |
|
1.3.6.1.4.1.2011.6.108.1.2.1 | no-access |
R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this entry is hwRegisterSignalIndex |
||
hwRegisterSignalIndex | 1.3.6.1.4.1.2011.6.108.1.2.1.1 | integer32 | no-access |
R2 signaling profile index |
hwRegisterOutgoingSignalType | 1.3.6.1.4.1.2011.6.108.1.2.1.2 | integer | read-write |
Signaling type of outgoing office register Options: 1. mfc(1)-the register outgoing signal type is mfc 2. pulse(2) -the register outgoing signal type is pulse 3. dtmf(3) -the register outgoing signal type is dtmf 4. mfp(4) -the register outgoing signal type is mfp 5. dpmfp(5) -the register outgoing signal type is dpmfp Enumeration: 'mfp': 4, 'dpmfp': 5, 'mfc': 1, 'dtmf': 3, 'pulse': 2. |
hwSignalSendVoltage | 1.3.6.1.4.1.2011.6.108.1.2.1.3 | integer32 | read-write |
Register signal transmit level(dbm) 1:-25dBm 2:-24dBm 3:-23dBm 4:-22dBm 5:-21dBm 6:-20dBm 7:-19dBm 8:-18dBm 9:-17dBm 10:-16dBm 11:-15dBm 12:-14dBm 13:-13dBm 14:-12dBm 15:-11dBm 16:-10dBm 17:-9dBm 18:-8dBm 19:-7dBm 20:-6dBm 21:-5dBm 22:-4dBm 23:-3dBm} |
hwBackPulseTime | 1.3.6.1.4.1.2011.6.108.1.2.1.4 | integer32 | read-write |
Backword pulse duration(Multiple of 10; unit: ms) |
hwDTMFSendTime | 1.3.6.1.4.1.2011.6.108.1.2.1.5 | integer32 | read-write |
DTMF signal transmit duration (ms) |
hwDTMFSendInterval | 1.3.6.1.4.1.2011.6.108.1.2.1.6 | integer32 | read-write |
DTMF signal transmit interval (ms) |
hwNoCallerPermit | 1.3.6.1.4.1.2011.6.108.1.2.1.7 | integer | read-write |
Can the call be established without a calling party Options: 1. yes(1)- permit send caller number 2. no(2) - not permit send caller number Enumeration: 'yes': 1, 'no': 2. |
hwNumberMaxInterval | 1.3.6.1.4.1.2011.6.108.1.2.1.8 | integer32 | read-write |
Max. dialing interval (s) |
hwSignalKeepMaxTime | 1.3.6.1.4.1.2011.6.108.1.2.1.9 | integer32 | read-write |
Max. signal duration (s) |
hwReceiveNumberMaxInterval | 1.3.6.1.4.1.2011.6.108.1.2.1.10 | integer32 | read-write |
Max. interval of receiving calling(callee) signals (s) |
hwSignalStopPermitTime | 1.3.6.1.4.1.2011.6.108.1.2.1.11 | integer32 | read-write |
Max. duration of signal interruption |
hwWaitCallerCategoryTime | 1.3.6.1.4.1.2011.6.108.1.2.1.12 | integer32 | read-write |
Wait time for receiving calling party type (s) |
hwWaitBsignalTime | 1.3.6.1.4.1.2011.6.108.1.2.1.13 | integer32 | read-write |
Wait time for receiving group B signal (s) |
hwNumberSendMode | 1.3.6.1.4.1.2011.6.108.1.2.1.14 | integer | read-write |
Signal transmit mode Options: 1. immediate(1)- number send immediately 2. delay(2) - number send delay Enumeration: 'delay': 2, 'immediate': 1. |
hwCallingNumberMaxLength | 1.3.6.1.4.1.2011.6.108.1.2.1.15 | integer32 | read-write |
Max. length of calling number |
hwCompellingSequenceKeepaliveTime | 1.3.6.1.4.1.2011.6.108.1.2.1.16 | integer32 | read-write |
Compelling sequence keepalive time for register signaling (ms) |
hwSendPulseSignal | 1.3.6.1.4.1.2011.6.108.1.2.1.17 | integer | read-write |
Whether to send sending-finished signals Options: 1. yes(1)- send pulse signal 2. no(2) - do not send pulse signal Enumeration: 'yes': 1, 'no': 2. |
hwRegisterIncomingSignalType | 1.3.6.1.4.1.2011.6.108.1.2.1.18 | integer | read-write |
Signaling type of incoming office register Options: 1. mfc(1)-the register incoming signal type is mfc 2. pulse(2) -the register incoming signal type is pulse 3. dtmf(3) -the register incoming signal type is dtmf 4. mfp(4) -the register incoming signal type is mfp 5. dpmfp(5) -the register incoming signal type is dpmfp Enumeration: 'mfp': 4, 'dpmfp': 5, 'mfc': 1, 'dtmf': 3, 'pulse': 2. |
hwLineSignalAttributeTable | 1.3.6.1.4.1.2011.6.108.1.3 | no-access |
R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this table is hwLineSignalIndex |
|
1.3.6.1.4.1.2011.6.108.1.3.1 | no-access |
R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this entry is hwLineSignalIndex |
||
hwLineSignalIndex | 1.3.6.1.4.1.2011.6.108.1.3.1.1 | integer32 | no-access |
R2 profile index |
hwLineSignalType | 1.3.6.1.4.1.2011.6.108.1.3.1.2 | integer | read-write |
Line signaling type Options: 1. l1b(1)-line signal type is l1b 2. l2b(2) -line signal type is l2b 3. l3b(3) -line signal type is l3b 4. pulse(4) -line signal type is pulse Enumeration: 'l2b': 2, 'l3b': 3, 'pulse': 4, 'l1b': 1. |
hwWaitSeizeAckTime | 1.3.6.1.4.1.2011.6.108.1.3.1.3 | integer32 | read-write |
Wait time for receiving occupation verification signal (ms) |
hwWaitAnswerTime | 1.3.6.1.4.1.2011.6.108.1.3.1.4 | integer32 | read-write |
Wait time for receiving answer signal (s) |
hwWaitClearForwardTime | 1.3.6.1.4.1.2011.6.108.1.3.1.5 | integer32 | read-write |
Wait time for receiving forward release signal (ms) |
hwWaitProtectTime | 1.3.6.1.4.1.2011.6.108.1.3.1.6 | integer32 | read-write |
Wait time for receiving release protection signal (ms) |
hwAddressSendListTable | 1.3.6.1.4.1.2011.6.108.1.4 | no-access |
Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this table is hwAddresssendInformationIndex |
|
1.3.6.1.4.1.2011.6.108.1.4.1 | no-access |
Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this entry is hwAddresssendInformationIndex |
||
hwAddresssendInformationIndex | 1.3.6.1.4.1.2011.6.108.1.4.1.1 | integer32 | no-access |
R2 profile index |
hwAddressSendInformationDI | 1.3.6.1.4.1.2011.6.108.1.4.1.2 | integer | read-only |
Whether to send called numbers Options: 1. yes(1)-register signal address send callee number Enumeration: 'yes': 1. |
hwAddressSendInformationSI | 1.3.6.1.4.1.2011.6.108.1.4.1.3 | integer | read-write |
Whether to send calling numbers Options: 1. yes(1)-register signal address send caller number 2. no(2)-register signal address does not send caller number Enumeration: 'yes': 1, 'no': 2. |
hwAddressSendInformationSC | 1.3.6.1.4.1.2011.6.108.1.4.1.4 | integer | read-only |
Whether to send calling party types Options: 1. yes(1)-register signal address send caller type Enumeration: 'yes': 1. |
hwAddressSendInformationES | 1.3.6.1.4.1.2011.6.108.1.4.1.5 | integer | read-write |
Whether to send echo cancelation info Options: 1. yes(1)-register signal address send echo suppression 2. no(2)-register signal address does not send echo suppression Enumeration: 'yes': 1, 'no': 2. |
hwAddressSendInformationCC | 1.3.6.1.4.1.2011.6.108.1.4.1.6 | integer | read-write |
Whether to send country code Options: 1. yes(1)-register signal address send country code 2. no(2)-register signal address does not send country code Enumeration: 'yes': 1, 'no': 2. |
hwAddressSendInformationDISC | 1.3.6.1.4.1.2011.6.108.1.4.1.7 | integer | read-write |
Whether to send separating signaling Options: 1. yes(1)-register signal address send discrimination flag 2. no(2)-register signal address does not send discrimination flag Enumeration: 'yes': 1, 'no': 2. |
hwAddressSendInformationNAC | 1.3.6.1.4.1.2011.6.108.1.4.1.8 | integer | read-write |
Whether to send circuit basic info Options: 1. yes(1)-register signal address send circuit character 2. no(2)-register signal address does not send circuit character Enumeration: 'yes': 1, 'no': 2. |
hwAddressSendInformationSP | 1.3.6.1.4.1.2011.6.108.1.4.1.9 | integer | read-only |
Whether to send the calling priority Options: 1. yes(1)-register signal address send caller priority 2. no(2)-register signal address does not send caller priority Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveListTable | 1.3.6.1.4.1.2011.6.108.1.5 | no-access |
Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this table is hwAddressReceiveInformationIndex |
|
1.3.6.1.4.1.2011.6.108.1.5.1 | no-access |
Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this entry is hwAddressReceiveInformationIndex |
||
hwAddressReceiveInformationIndex | 1.3.6.1.4.1.2011.6.108.1.5.1.1 | integer32 | no-access |
R2 profile index |
hwAddressReceiveInformationDI | 1.3.6.1.4.1.2011.6.108.1.5.1.2 | integer | read-only |
Whether to receive called numbers Options: 1. yes(1)-register signal address receive callee number Enumeration: 'yes': 1. |
hwAddressReceiveInformationSI | 1.3.6.1.4.1.2011.6.108.1.5.1.3 | integer | read-write |
Whether to receive calling numbers Options: 1. yes(1)-register signal address receive calling number 2. no(2)-register signal address does not receive calling number Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationSC | 1.3.6.1.4.1.2011.6.108.1.5.1.4 | integer | read-write |
Whether to receive calling party types Options: 1. yes(1)-register signal address receive calling user type 2. no(2)-register signal address does not receive calling user type Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationES | 1.3.6.1.4.1.2011.6.108.1.5.1.5 | integer | read-write |
Whether to receive echo cancelation info Options: 1. yes(1)-register signal address receive echo suppression 2. no(2)-register signal address does not receive echo suppression Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationCC | 1.3.6.1.4.1.2011.6.108.1.5.1.6 | integer | read-write |
Whether to receive country code Options: 1. yes(1)-register signal address receive country code 2. no(2)-register signal address does not receive country code Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationDISC | 1.3.6.1.4.1.2011.6.108.1.5.1.7 | integer | read-write |
Whether to receive separating signaling Options: 1. yes(1)-register signal address receive distinctive indication 2. no(2)-register signal address does not receive distinctive indication Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationNAC | 1.3.6.1.4.1.2011.6.108.1.5.1.8 | integer | read-write |
Whether to receive circuit basic info Options: 1. yes(1)-register signal address receive circuit character 2. no(2)-register signal address does not receive circuit character Enumeration: 'yes': 1, 'no': 2. |
hwAddressReceiveInformationSP | 1.3.6.1.4.1.2011.6.108.1.5.1.9 | integer | read-only |
Whether to receive calling priority Options: 1. yes(1)-register signal address receive caller priority 2. no(2)-register signal address does not receive caller priority Enumeration: 'yes': 1, 'no': 2. |
hwRequestCallerLineNoPosition | 1.3.6.1.4.1.2011.6.108.1.5.1.10 | integer32 | read-write |
Called number digits before requesting calling number (The calling number must be requested after the calling party type.) |
hwRequestCallerLineTypePosition | 1.3.6.1.4.1.2011.6.108.1.5.1.11 | integer32 | read-write |
Called number digits before requesting calling party type (The calling party type must be requested before the calling number.) |
hwR2SignalTypeVersionTable | 1.3.6.1.4.1.2011.6.108.1.6 | |||
hwSignalTypeVersion | 1.3.6.1.4.1.2011.6.108.1.6.1 | octet string | read-only |
Version of R2 signaling type file |
hwR2SignalTypeTable | 1.3.6.1.4.1.2011.6.108.1.7 | no-access |
R2 signaling type table,this table is used to query R2 signal type information The index of this table is hwSignalTypeIndex |
|
1.3.6.1.4.1.2011.6.108.1.7.1 | no-access |
R2 signaling type table,this table is used to query R2 signal type information The index of this entry is hwSignalTypeIndex |
||
hwSignalTypeIndex | 1.3.6.1.4.1.2011.6.108.1.7.1.1 | integer32 | no-access |
R2 signaling type index |
hwSignalTypeName | 1.3.6.1.4.1.2011.6.108.1.7.1.2 | octet string | read-write |
R2 signaling type name The names of the preconfigured multiple countries adaption profiles with IDs ranging from 0 to 9 cannot be modified |