Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hwTest 1.3.6.1.4.1.2011.6.21
       hwTestCommon 1.3.6.1.4.1.2011.6.21.1
This MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board to the phone set is normal. Common MELT operations include starting a MELT test, querying the test result, querying the calibration data, and starting and stopping a searching tone test.
           hwTestCommonMib 1.3.6.1.4.1.2011.6.21.1.1
               hwTestCommonMIBObjects 1.3.6.1.4.1.2011.6.21.1.1.1
                   hwTestGroupOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.1 no-access
Table of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this table is hwTestGroupNo.
                       hwTestGroupOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.1.1 no-access
Table of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this entry is hwTestGroupNo.
                           hwTestGroupNo 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.1 integer32 no-access
Test group number. The MD5500 supports the number that ranges from 0 to 240. The MA5100 supports the number that ranges from 0 to 4. The MA5300 supports the number that ranges from 0 to 63.
                           hwTestBoardIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.2 integer32 read-only
Test board IfIndex.
                           hwTestGroupAssistIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.3 integer32 read-only
TestGroupAssist port IfIndex.
                           hwTestGroupAssistTelNo 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.4 octet string read-only
Assistant telephone number. The maximum length is 16 Octets.
                           hwTestGroupRowStatus 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.5 rowstatus read-only
Present operation status of a row. Options: 1. active(1), -the present operation status of the row is active 2. notInService(2), -the present operation status of the row is notInService 3. notReady(3), -the present operation status of the row is notReady 4. createAndGo(4), -the present operation status of the row is createAndGo 5. createAndWait(5), -the present operation status of the row is createAndWait 6. destroy(6) -the present operation status of the row is destroy
                   hwLoopLineTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.2 no-access
This table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this table is ifindex.
                       hwLoopLineTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.2.1 no-access
This table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this entry is ifindex.
                           hwLoopLineTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.1 integer read-only
MELT operation type Options: 1. stop(1) -stop a MELT test 2. start(2) -start a MELT test 3. invalid(-1) -invalid value Enumeration: 'start': 2, 'stop': 1, 'invalid': -1.
                           hwLoopLineTestVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.2 integer read-only
Indicates whether a voltage exists on the line under test. Options: 1. notest(1) -the voltage does not exist on the line under test 2. test(2) -the voltage exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.3 integer read-only
Indicates whether resistance exists on the line under test. Options: 1. notest(1) -resistance does not exist on the line under test 2. test(2) -resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestCapacitance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.4 integer read-only
Indicates whether capacitance exists on the line under test. Options: 1. notest(1) -capacitance does not exist on the line under test 2. test(2) -capacitance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestLoopResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.5 integer read-only
Indicates whether loop resistance exists on the line under test. Options: 1. notest(1) -loop resistance does not exist on the line under test 2. test(2) -loop resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestPoleResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.6 integer read-only
Indicates whether pole resistance exists on the line under test. Options: 1. notest(1) -Pole resistance does not exist on the line under test 2. test(2) -Pole resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.7 integer read-only
Identify whether to start a test when the line is busy. The system will excecute a corresponding operation according to the configuration that a user specifies, for example, to cancel the test or to force to test. Options: 1. busyNoTest(1) -perform no test when a port is busy 2. busyTest(2) -perform a remedy test when a port is busy 3. busystrenTest(3) -force to test when a port is busy 4. deferredTest(4) -defer a test when a port is busy 5. invalid(-1) -invalid value Default: busyTest(1) If the value of this leaf is deferredTest(4), both hwLoopLineTestDeferredTime and hwLoopLineTestTimeoutProc must be set. Enumeration: 'busystrenTest': 3, 'deferredTest': 4, 'busyNoTest': 1, 'invalid': -1, 'busyTest': 2.
                           hwLoopLineTestStatus 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.8 integer read-only
Indicates the result of MELT test. Options: 1. normal(1) -the MELT test is successful 2. testFail(2) -the MELT test fails 3. portBusy(3) -the MELT test port is busy 4. testOutOfTime(4) -the MELT test times out 5. testingAbnormal(5) -the MELT test is abnormal 6. broadbandtesting(6)-the MELT test is broadbandtesting 7. capturefail(7) -the MELT test fails to capture 8. notratb(8) -the relay transfer board of the MELT test does not exist 9. testcanceled(9) -the MELT test is canceled 10. invalid(-1) -invalid value Enumeration: 'testFail': 2, 'notratb': 8, 'normal': 1, 'invalid': -1, 'testOutOfTime': 4, 'testcanceled': 9, 'portBusy': 3, 'broadbandtesting': 6, 'capturefail': 7, 'testingAbnormal': 5.
                           hwLoopLineTestConclusion 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.9 integer read-only
MELT test conclusion Options: 1. normal(1) -the test conclusion is normal 2. meetLine(2) -the test conclusion is meetLine 3. aLineMix(3) -the test conclusion is aLineMix 4. bLineMix(4) -the test conclusion is bLineMix 5. doubleMix(5) -the test conclusion is doubleMix 6. aLineEarth(6) -the test conclusion is aLineEarth 7. bLineEarth(7) -the test conclusion is bLineEarth 8. doublelineearth(8) -the test conclusion is doublelineearth 9. selfMix(9) -the test conclusion is selfMix 10. abLine(10) -the test conclusion is abLine 11. aLineFree(11) -the test conclusion is aLineFree 12. bLineEarthFree(12) -the test conclusion is bLineEarthFree 13. doubleLineEarthFree(13) -the test conclusion is doubleLineEarthFree 14. abLineFree(14) -the test conclusion is abLineFree 15. killLine(15) -the test conclusion is killLine 16. noPutDownTele(16) -the test conclusion is noPutDownTele 17. unknow(17) -the test conclusion is unknow 18. selfMixinMDF(18) -the test conclusion is selfMixinMDF 19. selfMixoutMDF(19) -the test conclusion is selfMixoutMDF 20. cutLineinMDF(20) -the test conclusion is cutLineinMDF 21. cutLineoutMDF(21) -the test conclusion is cutLineoutMDF 22. dCvoltagePowerFeed(30) -the test conclusion is dCvoltagePowerFeed 23. aCvoltageRinging(31) -the test conclusion is aCvoltageRinging 24. dCvoltageOffhook(32) -the test conclusion is dCvoltageOffhook 25. dCvoltage(33) -the test conclusion is dCvoltage 26. aCvoltage(34) -the test conclusion is aCvoltage 27. abImpedance(35) -the test conclusion is abImpedance 28. baImpedance(36) -the test conclusion is baImpedance 29. agImpedance(37) -the test conclusion is agImpedance 30. bgImpedance(38) -the test conclusion is bgImpedance 31. agACCurrent(39) -the test conclusion is agACCurrent 32. bgACCurrent(41) -the test conclusion is bgACCurrent 33. abACCurrent(42) -the test conclusion is abACCurrent 34. agDCCurrent(43) -the test conclusion is agDCCurrent 35. bgDCCurrent(44) -the test conclusion is bgDCCurrent 36. abDCCurrent(45) -the test conclusion is abDCCurrent 37. loopCurrent(46) -the test conclusion is loopCurrent 38. noise(47) -the test conclusion is noise 39. abRFaultId(91) -the test conslusion is ab Line all fault 40. aRFaultId(92) -the test conslusion is a Line fault 41. bRFaultId(93) -the test conslusion is b Line fault 42. abLeakId(94) -the test conslusion is ab Line all leak 43. aLeakId(95) -the test conslusion is a Line leak 44. bLeakId(96) -the test conslusion is b line leak 45. abFvacLevelH(97) -the test conslusion is ab dangerous AC to ground 46. aFvacLevelH(98) -the test conslusion is a dangerous AC to ground 47. bFvacLevelH(99) -the test conslusion is b dangerous AC to ground 48. abFvacLevelI(100) -the test conslusion is ab EMF AC to ground 49. aFvacLevelI(101) -the test conslusion is a EMF AC to ground 50. bFvacLevelI(102) -the test conslusion is b EMF AC to ground 51. abFvacLevelO(103) -the test conslusion is ab other dangerous AC to ground 52. aFvacLevelO(104) -the test conslusion is a other dangerous AC to ground 53. bFvacLevelO(105) -the test conslusion is b other dangerous AC to ground 54. abFvDcLevelH(106) -the test conslusion is ab dangerous DC to ground 55. aFvDcLevelH(107) -the test conslusion is a dangerous DC to ground 56. bFvDcLevelH(108) -the test conslusion is b dangerous DC to ground 57. abFvDcLevelI(109) -the test conslusion is ab EMF DC to ground 58. aFvDcLevelI(110) -the test conslusion is a EMF DC to ground 59. bFvDcLevelI(111) -the test conslusion is b EMF DC to ground 60. abFvDcLevelO(112) -the test conslusion is ab other dangerous DC to ground 61. aFvDcLevelO(113) -the test conslusion is a other dangerous DC to ground 62. bFvDcLevelO(114) -the test conslusion is b other dangerous DC to ground 63. fesIdPPA(115) -the test conslusion is ab PPA 64. fesIdPPAInv(116) -the test conslusion is ab reverse PPA 65. fesId2PPA(117) -the test conslusion is ab two PPA 66. fesId2PPAInv(118) -the test conslusion is ab two reverse PPA 67. etsiXdslSignature(119) -the test conslusion is ETSI XDSL Signature 68. fetIdEr(120) -the test conslusion is exist electronic ring terminal 69. abreak(121) -the test conslusion is a line break 70. bbreak(122) -the test conslusion is b line break 71. abreakInMDF(123) -the test conslusion is a line break InMDF 72. bbreakInMDF(124) -the test conslusion is b line break InMDF 73. abreakOutMDF(125) -the test conslusion is a line break OutMDF 74. bbreakOutMDF(126) -the test conslusion is b line break OutMDF 75. invalid(-1) -the test conclusion is invalid Enumeration: 'fesIdPPAInv': 116, 'abFvDcLevelO': 112, 'fetIdEr': 120, 'dCvoltage': 33, 'fesId2PPA': 117, 'abreakOutMDF': 125, 'selfMix': 9, 'cutLineinMDF': 20, 'bRFaultId': 93, 'abFvDcLevelI': 109, 'aLeakId': 95, 'abFvacLevelI': 100, 'abFvacLevelH': 97, 'aCvoltageRinging': 31, 'invalid': -1, 'selfMixinMDF': 18, 'abACCurrent': 42, 'agImpedance': 37, 'bFvacLevelI': 102, 'bFvacLevelH': 99, 'aLineEarth': 6, 'aLineFree': 11, 'killLine': 15, 'agACCurrent': 39, 'bLineEarthFree': 12, 'abDCCurrent': 45, 'normal': 1, 'doubleLineEarthFree': 13, 'fesId2PPAInv': 118, 'bFvDcLevelH': 108, 'bFvDcLevelI': 111, 'aFvacLevelO': 104, 'abImpedance': 35, 'abreakInMDF': 123, 'bFvDcLevelO': 114, 'aFvacLevelH': 98, 'meetLine': 2, 'doubleMix': 5, 'aFvacLevelI': 101, 'agDCCurrent': 43, 'noise': 47, 'abLine': 10, 'unknow': 17, 'abLineFree': 14, 'aRFaultId': 92, 'aFvDcLevelI': 110, 'abLeakId': 94, 'aFvDcLevelO': 113, 'fesIdPPA': 115, 'bbreakOutMDF': 126, 'bLeakId': 96, 'bbreak': 122, 'baImpedance': 36, 'bgACCurrent': 41, 'doublelineearth': 8, 'etsiXdslSignature': 119, 'aFvDcLevelH': 107, 'dCvoltageOffhook': 32, 'loopCurrent': 46, 'bLineEarth': 7, 'aCvoltage': 34, 'abreak': 121, 'bgDCCurrent': 44, 'bLineMix': 4, 'abFvDcLevelH': 106, 'bbreakInMDF': 124, 'noPutDownTele': 16, 'bgImpedance': 38, 'dCvoltagePowerFeed': 30, 'abFvacLevelO': 103, 'selfMixoutMDF': 19, 'aLineMix': 3, 'cutLineoutMDF': 21, 'abRFaultId': 91, 'bFvacLevelO': 105.
                           hwLoopLineTestACAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.10 integer32 read-only
Indicates the A->ground AC voltage. Unit: mV
                           hwLoopLineTestACBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.11 integer32 read-only
Indicates the B->ground AC voltage. Unit: mV
                           hwLoopLineTestACAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.12 integer32 read-only
Indicates the A->B AC voltage. Unit: mV
                           hwLoopLineTestDCAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.13 integer32 read-only
Indicates the A->ground DC voltage. Unit: mV
                           hwLoopLineTestDCBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.14 integer32 read-only
Indicates the B->ground DC voltage. Unit: mV
                           hwLoopLineTestDCAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.15 integer32 read-only
Indicates the A->B DC voltage. Unit: mV
                           hwLoopLineTestRAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.16 integer32 read-only
Indicates the A->ground insulation resistance. Unit: ohm
                           hwLoopLineTestRBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.17 integer32 read-only
Indicates the B->ground insulation resistance. Unit: ohm
                           hwLoopLineTestRAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.18 integer32 read-only
Indicates the A->B insulation resistance. Unit: ohm
                           hwLoopLineTestCapAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.19 integer32 read-only
Indicates the A->ground capacitance. Unit: nF
                           hwLoopLineTestCapBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.20 integer32 read-only
Indicates the B->ground capacitance. Unit: nF
                           hwLoopLineTestCapAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.21 integer32 read-only
Indicates the A->B capacitance. Unit: nF
                           hwLoopLineTestLR 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.22 integer32 read-only
Indicates the loop resistance. Unit: ohm
                           hwLoopLineTestRABResPole 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.23 integer32 read-only
Indicates the A->B polarity reversal resistance. Unit: ohm
                           hwLoopLineTestMSocket 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.24 integer read-only
Indicates the M-socket connection. Options: 1. notconnected(1) -the M-socket is not connected 2. connected(2) -the M-socket is connected 3. aBReversed(3) -the wire A and wire B are reversed Enumeration: 'notconnected': 1, 'aBReversed': 3, 'connected': 2.
                           hwLoopLineTestBtssPowerProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.25 integer read-only
Loop line test-BTSS line with power processing. Options: 1. noTest(1) -not test 2. test(2) -test 3. invalid(-1) -invalid value Enumeration: 'test': 2, 'invalid': -1, 'noTest': 1.
                           hwLoopLineTestImpedance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.26 integer read-only
Loop line test-impedance. Options: 1. notest(1) -not test 2. test(2) -test Enumeration: 'test': 2, 'notest': 1.
                           hwLoopLineTestImpedanceAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.27 integer32 read-only
A->B impedance (unit: ohm)
                           hwLoopLineTestImpedanceBA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.28 integer32 read-only
B->A impedance (unit: ohm)
                           hwLoopLineTestImpedanceAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.29 integer32 read-only
A->ground impedance (unit: ohm)
                           hwLoopLineTestImpedanceBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.30 integer32 read-only
B->ground impedance (unit: ohm)
                           hwLoopLineTestCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.31 integer read-only
Loop line test-current. Options: 1. notest(1) -not test 2. test(2) -test Enumeration: 'test': 2, 'notest': 1.
                           hwLoopLineTestACCurrentAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.32 integer32 read-only
A->ground AC current (unit: mA)
                           hwLoopLineTestACCurrentBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.33 integer32 read-only
B->ground AC current (unit: mA)
                           hwLoopLineTestACCurrentAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.34 integer32 read-only
AB AC current (unit: mA)
                           hwLoopLineTestDCCurrentAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.35 integer32 read-only
A->ground DC current (unit: mA)
                           hwLoopLineTestDCCurrentBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.36 integer32 read-only
B->ground DC current (unit: mA)
                           hwLoopLineTestDCCurrentAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.37 integer32 read-only
AB DC current (unit: mA)
                           hwLoopLineTestLoopCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.38 integer read-only
Loop line test-loop current. Options: 1. notest(1) -not test 2. test(2) -test Enumeration: 'test': 2, 'notest': 1.
                           hwLoopLineTestLC 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.39 integer32 read-only
Loop current (unit: uA)
                           hwLoopLineTestNoise 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.40 integer read-only
Loop line test-noise. Options: 1. notest(1) -not test 2. test(2) -test Enumeration: 'test': 2, 'notest': 1.
                           hwLoopLineTestN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.41 integer32 read-only
Noise (unit: dBm)
                           hwLoopLineTestPPA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.42 integer read-only
Indicates whether PPA exists on the line under test. Options: 1. notest(1) -PPA does not exist on the line under test 2. test(2) -PPA exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestPPAResult 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.43 integer read-only
Indicates whether the PPA exists. Options: 1. noexist(1) -PPA does not exist 2. exist(2) -PPA exists 3. inverseexist(3) -PPA inverse exists 4. invalid(-1) -invalid value Enumeration: 'inverseexist': 3, 'exist': 2, 'noexist': 1, 'invalid': -1.
                           hwLoopLineTestDeferredTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.44 integer32 read-only
Indicates the deferred time. Unit: minute This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4). Default: 30
                           hwLoopLineTestTimeoutProc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.45 integer read-only
Indicates the timeout processing. Options: 1. notest(1) -if the deferred time times out and the port is still busy the test will be canceled 2. test(2) -if the deferred time times out and the port is still busy the test will be forcedly started 3. invalid(-1) -invalid value This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4). Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestReverse 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.46 integer32 read-only
Reverse flag (0:normal test 1:reverse test)
                           hwLoopLineTestUtgAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.47 integer32 read-only
Frequency of foreign AC voltage source coupled to tip via Zbat_tip impedance. Unit: Hz
                           hwLoopLineTestUrgAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.48 integer32 read-only
Frequency of foreign AC voltage source coupled to ring via Zbat_ring impedance. Unit:Hz
                           hwLoopLineTestUtrAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.49 integer32 read-only
Frequency of foreign AC voltage source coupled to tip-ring via Zbat_tipring impedance. Unit:Hz
                           hwLoopLineTestItipAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.50 integer32 read-only
AC foreign current on the tip wire. Unit:uA
                           hwLoopLineTestIringAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.51 integer32 read-only
AC foreign current on the ring wire. Unit:uA
                           hwLoopLineTestItipDc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.52 integer32 read-only
DC foreign current on the tip wire. Unit:uA
                           hwLoopLineTestIringDc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.53 integer32 read-only
DC foreign current on the ring wire. Unit:uA
                           hwLoopLineTestRbattip 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.54 integer32 read-only
In presence of a foreign voltage, the equivalent coupling resistance of wire A. Unit:ohm
                           hwLoopLineTestRbatring 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.55 integer32 read-only
In presence of a foreign voltage, the equivalent coupling resistance of wire B. Unit:ohm
                           hwLoopLineTestRring 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.56 integer32 read-only
Resistance in series with the ring capacitance, for example when a ringer load or a passive R-C signature terminates the loop. It also includes the cable resistance R line but it does not include the 24 k feeding resistance. Unit: ohm
                           hwLoopLineTestCsig 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.57 integer32 read-only
Capacitance of an xDSL signal. Unit: nF
                           hwLoopLineTestVzener 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.58 integer32 read-only
Zener diode threshold in the case of an off-hook phone. Unit: mV
                           hwLoopLineTestRzener 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.59 integer32 read-only
DC tip-ring resistance measured in the case of an off-hook phone. Unit: ohm
                           hwLoopLineTestGtg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.60 integer32 read-only
Aggregate a->ground conductance. Unit: nS
                           hwLoopLineTestBtg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.61 integer32 read-only
Aggregate a->ground susceptance. Unit: nS
                           hwLoopLineTestGrg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.62 integer32 read-only
Aggregate b->ground conductance. Unit: nS
                           hwLoopLineTestBrg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.63 integer32 read-only
Aggregate b->ground susceptance. Unit: nS
                           hwLoopLineTestGtr 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.64 integer32 read-only
Aggregate a->b conductance. Unit: nS
                           hwLoopLineTestBtr 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.65 integer32 read-only
Aggregate a->b susceptance. Unit: nS
                           hwLoopLineTestSIGN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.66 truthvalue read-only
Indicates the ETSI xDSL Signature is detected or not.
                           hwLoopLineTestACFEM 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.67 truthvalue read-only
Indicates the presence of an AC foreign voltage above the threshold defined by ACFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.
                           hwLoopLineTestDCFEM 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.68 truthvalue read-only
Indicates the presence of a DC foreign voltage above the threshold defined by DCFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.
                           hwLoopLineTestONHK 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.69 truthvalue read-only
Indicates the presens of a phone in the on-hook state.
                           hwLoopLineTestOPEN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.70 truthvalue read-only
Indicates a->b resistance exceeds the threshold.
                           hwLoopLineTestSHORT 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.71 truthvalue read-only
Indicates that the insulation resistance is small.
                           hwLoopLineTestROH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.72 truthvalue read-only
Indicates a phone in the off-hook state.
                           hwLoopLineTestUtgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.73 integer32 read-only
Indicates the a->ground highest measurement DC voltage. Unit: mV
                           hwLoopLineTestUtgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.74 integer32 read-only
Indicates the a->ground lowest measurement DC voltage. Unit: mV
                           hwLoopLineTestUrgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.75 integer32 read-only
Indicates the b->ground highest measurement DC voltage. Unit: mV
                           hwLoopLineTestUrgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.76 integer32 read-only
Indicates the b->ground lowest measurement DC voltage. Unit: mV
                           hwLoopLineTestUtrPos 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.77 integer32 read-only
Indicates the a->b positive measurement DC voltage. Unit: mV
                           hwLoopLineTestUtrNeg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.78 integer32 read-only
Indicates the b->a measurement DC voltage. Unit: mV
                           hwLoopLineTestItgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.79 integer32 read-only
Indicates the current mapping the A-wire highest voltage for test. Unit: uA
                           hwLoopLineTestItgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.80 integer32 read-only
Indicates the current mapping the A-wire lowest voltage for test. Unit: uA
                           hwLoopLineTestIrgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.81 integer32 read-only
Indicates the current mapping the B-wire highest voltage for test. Unit: uA
                           hwLoopLineTestIrgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.82 integer32 read-only
Indicates the current mapping the B-wire lowest voltage for test. Unit: uA
                           hwLoopLineTestItrPos 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.83 integer32 read-only
Indicates the current mapping the A->B positive voltage for test. Unit: uA
                           hwLoopLineTestItrNeg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.84 integer32 read-only
Indicates the current mapping the A->B negative voltage for test. Unit: uA
                           hwLoopLineTestRinger 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.85 integer32 read-only
Indicates the detected ringer.
                           hwLoopLineTestPPARes 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.86 integer32 read-only
Indicates the resistance of PPA. Unit: ohm
                           hwLoopLineTestStartTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.87 dateandtime read-only
Indicates the start time and date of the MELT test.
                           hwLoopLineTestEndTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.88 dateandtime read-only
Indicates the end time and date of the MELT test.
                           hwLoopLineTestOprMeasuredFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.89 integer read-write
Indicates the measured frequency for complex impedance. Options: 1. frequency25Hz(0) -25 Hz 2. frequency275Hz(1) -275 Hz 3. invalid(-1) -invalid value Default: frequency25Hz(0) Enumeration: 'frequency275Hz': 1, 'frequency25Hz': 0, 'invalid': -1.
                           hwLoopLineTestIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.90 integer32 read-only
Port IfIndex.
                           hwLoopLineTestRequestID 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.91 integer32 read-only
Request ID. The value is the fourth parameter in the trap message.
                           hwLoopLineTestRABPole 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.92 integer32 read-only
Indicates the A->B polarity resistance. Unit: ohm
                           hwLoopLineTestACAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.93 integer read-only
Indicates whether the value of hwLoopLineTestACAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAG is valid 2. invalid(2) -the value of hwLoopLineTestACAG is invalid 3. notsupport(3) -the value of hwLoopLineTestACAG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestACBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.94 integer read-only
Indicates whether the value of hwLoopLineTestACBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACBG is valid 2. invalid(2) -the value of hwLoopLineTestACBG is invalid 3. notsupport(3) -the value of hwLoopLineTestACBG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestACABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.95 integer read-only
Indicates whether the value of hwLoopLineTestACAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAB is valid 2. invalid(2) -the value of hwLoopLineTestACAB is invalid 3. notsupport(3) -the value of hwLoopLineTestACAB is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestDCAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.96 integer read-only
Indicates whether the value of hwLoopLineTestDCAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAG is valid 2. invalid(2) -the value of hwLoopLineTestDCAG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestDCBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.97 integer read-only
Indicates whether the value of hwLoopLineTestDCBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCBG is valid 2. invalid(2) -the value of hwLoopLineTestDCBG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCBG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestDCABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.98 integer read-only
Indicates whether the value of hwLoopLineTestDCAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAB is valid 2. invalid(2) -the value of hwLoopLineTestDCAB is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAB is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.99 integer read-only
Indicates whether the value of hwLoopLineTestRAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAG is valid 2. invalid(2) -the value of hwLoopLineTestRAG is invalid 3. notsupport(3) -the value of hwLoopLineTestRAG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.100 integer read-only
Indicates whether the value of hwLoopLineTestRBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRBG is valid 2. invalid(2) -the value of hwLoopLineTestRBG is invalid 3. notsupport(3) -the value of hwLoopLineTestRBG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.101 integer read-only
Indicates whether the value of hwLoopLineTestRAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAB is valid 2. invalid(2) -the value of hwLoopLineTestRAB is invalid 3. notsupport(3) -the value of hwLoopLineTestRAB is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRABPoleFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.102 integer read-only
Indicates whether the value of hwLoopLineTestRABPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABPole is valid 2. invalid(2) -the value of hwLoopLineTestRABPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABPole is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRABResPoleFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.103 integer read-only
Indicates whether the value of hwLoopLineTestRABResPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABResPole is valid 2. invalid(2) -the value of hwLoopLineTestRABResPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABResPole is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCapAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.104 integer read-only
Indicates whether the value of hwLoopLineTestCapAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAG is valid 2. invalid(2) -the value of hwLoopLineTestCapAG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCapBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.105 integer read-only
Indicates whether the value of hwLoopLineTestCapBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapBG is valid 2. invalid(2) -the value of hwLoopLineTestCapBG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapBG is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCapABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.106 integer read-only
Indicates whether the value of hwLoopLineTestCapAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAB is valid 2. invalid(2) -the value of hwLoopLineTestCapAB is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAB is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRbattipFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.107 integer read-only
Indicates whether the value of hwLoopLineTestRbattip is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbattip is valid 2. invalid(2) -the value of hwLoopLineTestRbattip is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestRbatringFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.108 integer read-only
Indicates whether the value of hwLoopLineTestRbatring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbatring is valid 2. invalid(2) -the value of hwLoopLineTestRbatring is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestRringFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.109 integer read-only
Indicates whether the value of hwLoopLineTestRring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRring is valid 2. invalid(2) -the value of hwLoopLineTestRring is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestCsigFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.110 integer read-only
Indicates whether the value of hwLoopLineTestCsig is valid. Options: 1. valid(1) -the value of hwLoopLineTestCsig is valid 2. invalid(2) -the value of hwLoopLineTestCsig is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestPPAResFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.111 integer read-only
Indicates whether the value of hwLoopLineTestPPARes is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPARes is valid 2. invalid(2) -the value of hwLoopLineTestPPARes is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestVzenerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.112 integer read-only
Indicates whether the value of hwLoopLineTestVzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestVzener is valid 2. invalid(2) -the value of hwLoopLineTestVzener is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestRzenerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.113 integer read-only
Indicates whether the value of hwLoopLineTestRzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestRzener is valid 2. invalid(2) -the value of hwLoopLineTestRzener is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestSNMPRab 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.114 integer32 read-only
Indicates the A to B resistance (insulation resistance). Unit: ohm
                           hwLoopLineTestSNMPRabFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.115 integer read-only
Indicates whether the value of hwLoopLineTestSNMPRab is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRab is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRab is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestSNMPRba 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.116 integer32 read-only
Indicates the B to A resistance (insulation resistance). Unit: ohm
                           hwLoopLineTestSNMPRbaFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.117 integer read-only
Indicates whether the value of hwLoopLineTestSNMPRba is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRba is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRba is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestPPAResultFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.118 integer read-only
Indicates whether the value of hwLoopLineTestPPA is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPA is valid 2. invalid(2) -the value of hwLoopLineTestPPA is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUtgAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.119 integer read-only
Indicates whether the value of hwLoopLineTestUtgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcFreq is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestUrgAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.120 integer read-only
Indicates whether the value of hwLoopLineTestUrgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcFreq is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestUtrAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.121 integer read-only
Indicates whether the value of hwLoopLineTestUtrAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcFreq is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestItipAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.122 integer read-only
Indicates whether the value of hwLoopLineTestItipAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipAc is valid 2. invalid(2) -the value of hwLoopLineTestItipAc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipAc is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestIringAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.123 integer read-only
Indicates whether the value of hwLoopLineTestIringAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringAc is valid 2. invalid(2) -the value of hwLoopLineTestIringAc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringAc is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestItipDcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.124 integer read-only
Indicates whether the value of hwLoopLineTestItipDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipDc is valid 2. invalid(2) -the value of hwLoopLineTestItipDc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipDc is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestIringDcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.125 integer read-only
Indicates whether the value of hwLoopLineTestIringDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringDc is valid 2. invalid(2) -the value of hwLoopLineTestIringDc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringDc is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestGtgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.126 integer read-only
Indicates whether the value of hwLoopLineTestGtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtg is valid 2. invalid(2) -the value of hwLoopLineTestGtg is invalid 3. notsupport(3) -the value of hwLoopLineTestGtg is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBtgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.127 integer read-only
Indicates whether the value of hwLoopLineTestBtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtg is valid 2. invalid(2) -the value of hwLoopLineTestBtg is invalid 3. notsupport(3) -the value of hwLoopLineTestBtg is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestGrgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.128 integer read-only
Indicates whether the value of hwLoopLineTestGrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGrg is valid 2. invalid(2) -the value of hwLoopLineTestGrg is invalid 3. notsupport(3) -the value of hwLoopLineTestGrg is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBrgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.129 integer read-only
Indicates whether the value of hwLoopLineTestBrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBrg is valid 2. invalid(2) -the value of hwLoopLineTestBrg is invalid 3. notsupport(3) -the value of hwLoopLineTestBrg is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestGtrFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.130 integer read-only
Indicates whether the value of hwLoopLineTestGtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtr is valid 2. invalid(2) -the value of hwLoopLineTestGtr is invalid 3. notsupport(3) -the value of hwLoopLineTestGtr is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBtrFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.131 integer read-only
Indicates whether the value of hwLoopLineTestBtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtr is valid 2. invalid(2) -the value of hwLoopLineTestBtr is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestSIGNFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.132 integer read-only
Indicates whether the value of hwLoopLineTestSIGN is valid. Options: 1. valid(1) -the value of hwLoopLineTestSIGN is valid 2. invalid(2) -the value of hwLoopLineTestSIGN is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestACFEMFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.133 integer read-only
Indicates whether the value of hwLoopLineTestACFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestACFEM is valid 2. invalid(2) -the value of hwLoopLineTestACFEM is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestDCFEMFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.134 integer read-only
Indicates whether the value of hwLoopLineTestDCFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCFEM is valid 2. invalid(2) -the value of hwLoopLineTestDCFEM is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestONHKFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.135 integer read-only
Indicates whether the value of hwLoopLineTestONHK is valid. Options: 1. valid(1) -the value of hwLoopLineTestONHK is valid 2. invalid(2) -the value of hwLoopLineTestONHK is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestOPENFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.136 integer read-only
Indicates whether the value of hwLoopLineTestOPEN is valid. Options: 1. valid(1) -the value of hwLoopLineTestOPEN is valid 2. invalid(2) -the value of hwLoopLineTestOPEN is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestSHORTFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.137 integer read-only
Indicates whether the value of hwLoopLineTestSHORT is valid. Options: 1. valid(1) -the value of hwLoopLineTestSHORT is valid 2. invalid(2) -the value of hwLoopLineTestSHORT is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestROHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.138 integer read-only
Indicates whether the value of hwLoopLineTestROH is valid. Options: 1. valid(1) -the value of hwLoopLineTestROH is valid 2. invalid(2) -the value of hwLoopLineTestROH is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUtgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.139 integer read-only
Indicates whether the value of hwLoopLineTestUtgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcUp is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUtgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.140 integer read-only
Indicates whether the value of hwLoopLineTestUtgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcDown is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUrgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.141 integer read-only
Indicates whether the value of hwLoopLineTestUrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcUp is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUrgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.142 integer read-only
Indicates whether the value of hwLoopLineTestUrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcDown is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUtrPosFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.143 integer read-only
Indicates whether the value of hwLoopLineTestUtrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrPos is valid 2. invalid(2) -the value of hwLoopLineTestUtrPos is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestUtrNegFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.144 integer read-only
Indicates whether the value of hwLoopLineTestUtrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrNeg is valid 2. invalid(2) -the value of hwLoopLineTestUtrNeg is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestItgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.145 integer read-only
Indicates whether the value of hwLoopLineTestItgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestItgDcUp is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestItgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.146 integer read-only
Indicates whether the value of hwLoopLineTestItgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestItgDcDown is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestIrgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.147 integer read-only
Indicates whether the value of hwLoopLineTestIrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcUp is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestIrgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.148 integer read-only
Indicates whether the value of hwLoopLineTestIrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcDown is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestItrPosFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.149 integer read-only
Indicates whether the value of hwLoopLineTestItrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrPos is valid 2. invalid(2) -the value of hwLoopLineTestItrPos is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestItrNegFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.150 integer read-only
Indicates whether the value of hwLoopLineTestItrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrNeg is valid 2. invalid(2) -the value of hwLoopLineTestItrNeg is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestRingerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.151 integer read-only
Indicates whether the value of hwLoopLineTestRinger is valid. Options: 1. valid(1) -the value of hwLoopLineTestRinger is valid 2. invalid(2) -the value of hwLoopLineTestRinger is invalid Enumeration: 'valid': 1, 'invalid': 2.
                           hwLoopLineTestLRFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.152 integer read-only
Indicates whether the value of hwLoopLineTestLR is valid. Options: 1. valid(1) -the value of hwLoopLineTestLR is valid 2. invalid(2) -the value of hwLoopLineTestLR is invalid 3. notsupport(3) -the value of hwLoopLineTestLR is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestDcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.153 integer read-only
Indicates whether DcCurrent exists on the line under test. Options: 1. notest(1) -DcCurrent does not exist on the line under test 2. test(2) -DcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.154 integer read-only
Indicates whether AcCurrent exists on the line under test. Options: 1. notest(1) -AcCurrent does not exist on the line under test 2. test(2) -AcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestConductance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.155 integer read-only
Indicates whether conductance exists on the line under test. Options: 1. notest(1) -Conductance does not exist on the line under test 2. test(2) -Conductance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestSusceptance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.156 integer read-only
Indicates whether susceptance exists on the line under test. Options: 1. notest(1) -Susceptance does not exist on the line under test 2. test(2) -Susceptance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1) Enumeration: 'test': 2, 'invalid': -1, 'notest': 1.
                           hwLoopLineTestAcfrequencyA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.157 integer read-only
Indicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hz Enumeration: 'twentyFive': 2, 'sixteenDotSix': 1, 'unknown': 5, 'invalid': -1, 'fifty': 3, 'sixty': 4.
                           hwLoopLineTestAcfrequencyB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.158 integer read-only
Indicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hz Enumeration: 'twentyFive': 2, 'sixteenDotSix': 1, 'unknown': 5, 'invalid': -1, 'fifty': 3, 'sixty': 4.
                           hwLoopLineTestCapABH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.159 integer32 read-only
Indicates the A->B capacitance. Unit: nF
                           hwLoopLineTestCapABHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.160 integer read-only
Indicates whether the value of hwLoopLineTestCapABH is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapABH is valid 2. invalid(2) -the value of hwLoopLineTestCapABH is invalid 3. notsupport(3) -the value of hwLoopLineTestCapABH is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestGtrH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.161 integer32 read-only
Indicates the A->B conductance. Unit: nS
                           hwLoopLineTestGtrHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.162 integer read-only
Indicates whether the value of hwLoopLineTestGtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtrH is valid 2. invalid(2) -the value of hwLoopLineTestGtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestGtrH is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBtrH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.163 integer32 read-only
Indicates the A->B susceptance. Unit: nS
                           hwLoopLineTestBtrHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.164 integer read-only
Indicates whether the value of hwLoopLineTestBtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtrH is valid 2. invalid(2) -the value of hwLoopLineTestBtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestBtrH is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABDcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.165 integer32 read-only
Indicates the A->B Dc current. Unit: uA
                           hwLoopLineTestABDcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.166 integer read-only
Indicates whether the value of hwLoopLineTestABDcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABDcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABDcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABDcCurrent is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBADcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.167 integer32 read-only
Indicates the B->A Dc current. Unit: uA
                           hwLoopLineTestBADcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.168 integer read-only
Indicates whether the value of hwLoopLineTestBADcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBADcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBADcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBADcCurrent is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.169 integer32 read-only
Indicates the A->B Ac current. Unit: uArms
                           hwLoopLineTestABAcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.170 integer read-only
Indicates whether the value of hwLoopLineTestABAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABAcCurrent is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBAAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.171 integer32 read-only
Indicates the B->A Ac current. Unit: uArms
                           hwLoopLineTestBAAcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.172 integer read-only
Indicates whether the value of hwLoopLineTestBAAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBAAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBAAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBAAcCurrent is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCSfrequencyForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.173 integer32 read-only
Indicates the frequency for test capacitance and conductance. Unit: Hz
                           hwLoopLineTestCSfrequencyForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.174 integer read-only
Indicates whether the value of hwLoopLineTestCSfrequencyForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestCSfrequencyForTest is valid 2. invalid(2) -the value of hwLoopLineTestCSfrequencyForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestCSfrequencyForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestImpedanceForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.175 integer32 read-only
Indicates the resistance inputed in test abnormal voltage. Unit:
                           hwLoopLineTestImpedanceForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.176 integer read-only
Indicates whether the value of hwLoopLineTestImpedanceForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestImpedanceForTest is valid 2. invalid(2) -the value of hwLoopLineTestImpedanceForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestImpedanceForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestMaxVForSignature 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.177 integer32 read-only
Indicates the maximum voltage for signature. Unit: mV
                           hwLoopLineTestMaxVForSignatureFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.178 integer read-only
Indicates whether the value of hwLoopLineTestMaxVForSignature is valid. Options: 1. valid(1) -the value of hwLoopLineTestMaxVForSignature is valid 2. invalid(2) -the value of hwLoopLineTestMaxVForSignature is invalid 3. notsupport(3) -the value of hwLoopLineTestMaxVForSignature is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestAGMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.179 integer32 read-only
Indicates the A->ground max voltage in testing. Unit: mV
                           hwLoopLineTestAGMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.180 integer read-only
Indicates whether the value of hwLoopLineTestAGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestAGMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.181 integer32 read-only
Indicates the A->ground min voltage in testing. Unit: mV
                           hwLoopLineTestAGMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.182 integer read-only
Indicates whether the value of hwLoopLineTestAGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBGMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.183 integer32 read-only
Indicates the B->ground max voltage in testing. Unit: mV
                           hwLoopLineTestBGMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.184 integer read-only
Indicates whether the value of hwLoopLineTestBGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBGMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.185 integer32 read-only
Indicates the B->ground min voltage in testing. Unit: mV
                           hwLoopLineTestBGMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.186 integer read-only
Indicates whether the value of hwLoopLineTestBGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.187 integer32 read-only
Indicates the A->B max voltage in testing. Unit: mV
                           hwLoopLineTestABMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.188 integer read-only
Indicates whether the value of hwLoopLineTestABMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.189 integer32 read-only
Indicates the A->ground min voltage in testing. Unit: mV
                           hwLoopLineTestABMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.190 integer read-only
Indicates whether the value of hwLoopLineTestABMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMinVForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestAGMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.191 integer32 read-only
Indicates the A->ground max current. Unit: uA
                           hwLoopLineTestAGMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.192 integer read-only
Indicates whether the value of hwLoopLineTestAGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestAGMinCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.193 integer32 read-only
Indicates the A->ground min current. Unit: uA
                           hwLoopLineTestAGMinCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.194 integer read-only
Indicates whether the value of hwLoopLineTestAGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBGMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.195 integer32 read-only
Indicates the B->ground max current. Unit: uA
                           hwLoopLineTestBGMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.196 integer read-only
Indicates whether the value of hwLoopLineTestBGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestBGMinCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.197 integer32 read-only
Indicates the B->ground min current. Unit: uA
                           hwLoopLineTestBGMinCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.198 integer read-only
Indicates whether the value of hwLoopLineTestBGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.199 integer32 read-only
Indicates the A->B max current Unit: uA
                           hwLoopLineTestABMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.200 integer read-only
Indicates whether the value of hwLoopLineTestABMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestABMaxNegCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.201 integer32 read-only
Indicates the A->ground min current Unit: uA
                           hwLoopLineTestABMaxNegCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.202 integer read-only
Indicates whether the value of hwLoopLineTestABMaxNegCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxNegCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxNegCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxNegCForTest is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestLineALength 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.203 integer32 read-only
Indicates length of line A Unit: m
                           hwLoopLineTestLineBLength 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.204 integer32 read-only
Indicates length of line B Unit: m
                           hwLoopLineTestTermimalConcusion 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.205 integer read-only
Indicates Termimal Concusion Options: 1. noPhone(1) -the TermimalConcusion is not connect Phone 2. offHook(2) -the TermimalConcusion is connect phone and offhook 3. eTSIxDSLsignature(3) -the TermimalConcusion is ETSI XDSL Signature 4. abMixed(4) -the TermimalConcusion is ab line short 5. rcNetWork(5) -the TermimalConcusion is rcNetWork 6. elecRing(6) -the TermimalConcusion is elecRing 7. other(7) -the TermimalConcusion is other unknown terminal 8. abMixInMDF(8) -the TermimalConcusion is abMixInMDF 9. abMixOutMDF(9) -the TermimalConcusion is abMixOutMDF 10. invalid(-1) -the TermimalConcusion is invalid Enumeration: 'elecRing': 6, 'rcNetWork': 5, 'abMixInMDF': 8, 'abMixed': 4, 'invalid': -1, 'other': 7, 'offHook': 2, 'noPhone': 1, 'abMixOutMDF': 9, 'eTSIxDSLsignature': 3.
                           hwLoopLineTestMoreDataFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.206 integer read-only
Indicates is there more data Options: 1. more(1) -Indicates there is more data needs report,but needs a SNMP-GET oper. to get other data. 2. invalid(-1) -Indicates the value is invalid Enumeration: 'invalid': -1, 'more': 1.
                           hwLoopLineTestCtrLV 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.207 integer32 read-only
Aggregate tip-ring capacitance: CtrLV = Cco + Ctr + Cring, measured by means of low voltage ramps, such that it does NOT include the capacitance Csig whenever the ETSI Signature terminates the subscriber loop. Unit: nF
                           hwLoopLineTestCtrLVFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.208 integer read-only
Indicates whether the value of hwLoopLineTestCtrLV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrLV is valid 2. invalid(2) -the value of hwLoopLineTestCtrLV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrLV is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCtrHV 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.209 integer32 read-only
Aggregate tip-ring capacitance: CtrHV = Cco + Ctr + Cring + Csig, measured by means of high voltage ramps. It includes the capacitance Csig of an ETSI Signature whenever connected to the tip and ring wires. Unit: nF
                           hwLoopLineTestCtrHVFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.210 integer read-only
Indicates whether the value of hwLoopLineTestCtrHV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrHV is valid 2. invalid(2) -the value of hwLoopLineTestCtrHV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrHV is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCtrAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.211 integer32 read-only
Aggregate tip-ring capacitance: CtrAc = Cco + Ctr + Cring, measured by means of a low amplitude AC signal (either 25 Hz or 275 Hz). It does NOT include Csig. Unit: nF
                           hwLoopLineTestCtrAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.212 integer read-only
Indicates whether the value of hwLoopLineTestCtrAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrAc is valid 2. invalid(2) -the value of hwLoopLineTestCtrAc is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrAc is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRtgSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.213 integer32 read-only
Resistance in series with Ctg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
                           hwLoopLineTestRtgSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.214 integer read-only
Indicates whether the value of hwLoopLineTestRtgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtgSer is valid 2. invalid(2) -the value of hwLoopLineTestRtgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtgSer is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRrgSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.215 integer32 read-only
Resistance in series with Crg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
                           hwLoopLineTestRrgSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.216 integer read-only
Indicates whether the value of hwLoopLineTestRrgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRrgSer is valid 2. invalid(2) -the value of hwLoopLineTestRrgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRrgSer is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestRtrSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.217 integer32 read-only
Resistance in series with Ctring, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
                           hwLoopLineTestRtrSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.218 integer read-only
Indicates whether the value of hwLoopLineTestRtrSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtrSer is valid 2. invalid(2) -the value of hwLoopLineTestRtrSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtrSer is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestUtgAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.219 integer32 read-only
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tipground admittance Ytg = Gtg + i * Btg. Unit: V
                           hwLoopLineTestUtgAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.220 integer read-only
Indicates whether the value of hwLoopLineTestUtgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcAdmit is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestUrgAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.221 integer32 read-only
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the ringground admittance Yrg = Grg + i * Brg. Unit: V
                           hwLoopLineTestUrgAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.222 integer read-only
Indicates whether the value of hwLoopLineTestUrgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcAdmit is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestUtrAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.223 integer32 read-only
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tip-ring admittance Ytr = Gtr + i * Btr. Unit: V
                           hwLoopLineTestUtrAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.224 integer read-only
Indicates whether the value of hwLoopLineTestUtrAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcAdmit is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                           hwLoopLineTestCapterminal 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.225 integer read-only
A capacitive termination of the access line shall be identified by the capacitance measurement and the associated evaluation. The following average value for the capacitance Cabk of the measured cable can be assumed: Cabk = 0.083(Cae + Cbe). If the measured capacitance is Cab > Cabk + 50 nF for ADSL&VDSL, or Cab > Cabk + 100 nF for SHDSL, respectively, It can be assumed that a terminal device with a significant self-capacitance is connected to the line. The cable-factor 0.083 is determined by hwLoopLineTestSysConfigCableFactor. Options: 1. noexist(1) -Significant terminal device capacitance is not detected 2. exist(2) -Significant terminal device capacitance is detected Enumeration: 'exist': 2, 'noexist': 1.
                           hwLoopLineTestCapterminalFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.226 integer read-only
Indicates whether the value of hwLoopLineTestCapterminal is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapterminal is valid 2. invalid(2) -the value of hwLoopLineTestCapterminal is invalid 3. notsupport(3) -the value of hwLoopLineTestCapterminal is not support Enumeration: 'valid': 1, 'invalid': 2, 'notsupport': 3.
                   hwMeterTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.3 no-access
Operation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this table is ifIndex.
                       hwMeterTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.3.1 no-access
Operation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this entry is ifIndex.
                           hwMeterTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.1 integer read-only
Operation type. Options: 1. stop(1) -operation type is stop 2. start(2) -operation type is start Enumeration: 'start': 2, 'stop': 1.
                           hwMeterTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.2 integer read-only
Test items. Options: 1. inline(1) -in test 2. outline(2) -out test Enumeration: 'inline': 1, 'outline': 2.
                           hwMeterTestStatus 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.3 integer read-only
Test status. Options: 1. success(1) -no test on busy 2. fail(2) -remedy test on busy 3. portbusy(3) -forced test on busy 4. outoftime(4) -test out of time 5. testingAbnormal(5) -test abnormal 6. broadbandtesting(6) -broadband testing 7. capturefail(7) -capture fail 8. notratb(8) -relay transfer board not exist Enumeration: 'notratb': 8, 'outoftime': 4, 'success': 1, 'fail': 2, 'portbusy': 3, 'broadbandtesting': 6, 'capturefail': 7, 'testingAbnormal': 5.
                           hwMeterTestBusyFlag 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.4 integer read-write
Meter test busy flag. Options: 1. busyNoTest(1) -no test on busy 2. busyTest(2) -test on busy 3. busystrenTest(3) -forced test on busy Enumeration: 'busystrenTest': 3, 'busyNoTest': 1, 'busyTest': 2.
                   hwTestBoardDiagnoseTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.4 no-access
Operation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this table is ifIndex.
                       hwTestBoardDiagnoseTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.4.1 no-access
Operation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this entry is ifIndex.
                           hwTestBoardDiagnoseTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.1 integer read-only
Operation type. Options: 1. start(2) -operation type is start Enumeration: 'start': 2.
                           hwTestBoardDiagnoseTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.2 integer read-only
Self-diagnosis result. Options: 1. selfTestOver(1) -self-diagnosis successful 2. selfTestFail(2) -self-diagnosis failure 3. testingAbnormal(3) -test abnormal Enumeration: 'selfTestFail': 2, 'selfTestOver': 1, 'testingAbnormal': 3.
                           hwTestBoardDiagnoseTestRAM 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.3 integer read-only
System RAMRAM. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.4 integer read-only
Voltage. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestResistance 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.5 integer read-only
Resistance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestSignal 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.6 integer read-only
Signal circuit. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestDTMF 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.7 integer read-only
DTMF. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestRing 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.8 integer read-only
Ringing. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestOnOffHook 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.9 integer read-only
On/off hook. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestPole 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.10 integer read-only
Polarity reversal. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestISDNU 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.11 integer read-only
ISDN U port. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestBitErrCode 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.12 integer read-only
Error code test. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                           hwTestBoardDiagnoseTestCapacitance 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.13 integer read-only
Capacitance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal Enumeration: 'abnormal': 2, 'normal': 1.
                   hwTestBoardStatusQueryOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.5 no-access
Operation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this table is ifIndex.
                       hwTestBoardStatusQueryOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.5.1 no-access
Operation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this entry is ifIndex.
                           hwTestBoardStatusQueryOprType 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.1 integer read-only
Operation type. Options: 1. beginQuery(2) -start Enumeration: 'beginQuery': 2.
                           hwTestBoardStatusQueryResult 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.2 integer read-only
Query status. Options: 1. querySuccess(1) -query status successful 2. queryFail(2) -query status failure Enumeration: 'querySuccess': 1, 'queryFail': 2.
                           hwTestBoardStatusQueryVersion 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.3 integer32 read-only
Version.
                           hwTestBoardStatusQueryTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.4 integer read-only
Test item. Options: 1. testIdle(1) -idle 2. pstnUserInLineTest(2) -pstn inline test 3. userLineTest(3) -loop line test 4. phoneTest(4) -telephone test 5. manTestOutLine(5) -manual test outline 6. manTestInnerLine(6) -manual test inline 7. halfAutoUserCircuit(7) -half auto tss user circuit -meter interface 8. halfAutoTssPhoneCircuit(8) -half auto tss telephone circuit -meter interface 9. tssSelfTest(9) -Tss self test 10. testInnerBus(10) -test inline bus test 11. testOuterBus(11) -test outline bus test 12. digUserOutLineTest(12) -isdn outline test 13. digUserInnerLineTest(13) -isdn inline test 14. switchToStandIsdnTerminal(14) -switch to standard isdn terminal 15. switchToIsdnSpecialcode(15) -switch to isdn special service telephone number 16. testBoarDfault(16) -test board fault 17. pstnRemoteCallTest(17) -pstn user remote call test 18. indialtest(18) -in-dial test 19. coEmulate(33) -CO simulation test 20. cqtTest(34) -CQT test 21. cqtFRTest(35) -CQT Frequency Response Measurement 22. cqtTDRTest(36) -CQT Time Domain Reflectometry Measurement 23. cqtDMTTest(37) -CQT Data Rate Prediction Measurement 24. cqtNSETest(38) -CQT Noise Measurement 25. cqtLBTest(39) -CQT Longitudinal Balance Measurement 26. cqtLCTest(40) -CQT Load Coil Detection 27. internalcaptureTestedPort(61) -Capture tested port loopline 28. externalcaptureTestedPort(62) -Capture tested port inline 29. monitorTest(63) -monitor test 30. seltTest(64) -selt test 31. sendtoneTest(65) -tone send test 32. checktoneTest(66) -tone check test 33. autocalltest(67) -auto call test 34. anothermainboardistesting(241) -another main board is testing Enumeration: 'switchToStandIsdnTerminal': 14, 'cqtTDRTest': 36, 'cqtTest': 34, 'seltTest': 64, 'cqtLCTest': 40, 'cqtDMTTest': 37, 'pstnUserInLineTest': 2, 'checktoneTest': 66, 'halfAutoTssPhoneCircuit': 8, 'switchToIsdnSpecialcode': 15, 'cqtFRTest': 35, 'digUserInnerLineTest': 13, 'testBoarDfault': 16, 'internalcaptureTestedPort': 61, 'indialtest': 18, 'coEmulate': 33, 'testOuterBus': 11, 'manTestInnerLine': 6, 'monitorTest': 63, 'pstnRemoteCallTest': 17, 'userLineTest': 3, 'testInnerBus': 10, 'manTestOutLine': 5, 'externalcaptureTestedPort': 62, 'anothermainboardistesting': 241, 'phoneTest': 4, 'testIdle': 1, 'sendtoneTest': 65, 'cqtLBTest': 39, 'halfAutoUserCircuit': 7, 'tssSelfTest': 9, 'digUserOutLineTest': 12, 'autocalltest': 67, 'cqtNSETest': 38.
                           hwTestBoardStatusTestedBoardIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.5 integer32 read-only
Index of the tested port.
                   hwSearchingToneOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.6 no-access
This table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this table is ifindex.
                       hwSearchingToneOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.6.1 no-access
This table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this entry is ifindex.
                           hwSearchingToneOprType 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.1 integer read-write
Searching tone test-operation type. Options: 1. stop(1) -stop a searching tone test 2. start(2) -start a searching tone test 3. invalid(-1) -invalid value Enumeration: 'start': 2, 'stop': 1, 'invalid': -1.
                           hwSearchingToneLevel 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.2 integer32 read-write
Indicates the test voltage level of a searching tone test. Options: 1. -1 -Invalid value 2. 80..500 -(XDSL Range: 80-126 MXU voice Range: 80-500) Default: 120 -(XDSL Default: 120 MXU voice default:295) Unit: mV
                           hwSearchingToneFrequency 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.3 integer32 read-write
Indicates the test frequency of a searching tone test. Default: 800 Unit: Hz
                           hwSearchingToneDurationTime 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.4 integer32 read-write
Indicates the test duration of a searching tone test. Default: 9000 Unit: 0.1s
                           hwSearchingToneRemainingTime 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.5 integer32 read-only
Indicates the test remaining time of a searching tone test. Unit: 0.1s
                           hwSearchingToneBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.6 integer read-write
Searching tone test-busy flag. Options: 1. cancel(1) -when port is busy do not start a searching tone test 2. force(2) -when port is busy force to start a searching tone test 3. invalid(-1) -invalid value Enumeration: 'cancel': 1, 'force': 2, 'invalid': -1.
                   hwLoopLineTestCalibrationTable 1.3.6.1.4.1.2011.6.21.1.1.1.7 no-access
This table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this table is ifindex.
                       hwLoopLineTestCalibrationEntry 1.3.6.1.4.1.2011.6.21.1.1.1.7.1 no-access
This table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this entry is ifindex.
                           hwLoopLineTestAGCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1 integer32 read-only
Indicates the test calibration data of A->Ground capacitance. Unit: nF
                           hwLoopLineTestBGCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2 integer32 read-only
Indicates the test calibration data of B->Ground capacitance. Unit: nF
                           hwLoopLineTestABCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3 integer32 read-only
Indicates the test calibration data of A->B capacitance. Unit: nF
                   hwLoopLineTestMeltVerTable 1.3.6.1.4.1.2011.6.21.1.1.1.8 no-access
This table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this table are hwFrameIndex and hwSlotIndex.
                       hwLoopLineTestMeltVerEntry 1.3.6.1.4.1.2011.6.21.1.1.1.8.1 no-access
This table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this entry are hwFrameIndex and hwSlotIndex.
                           hwLoopLineTestMeltFactory 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.1 octet string read-only
MELT chipset manufacturer information Maximum length: 32 Octets
                           hwLoopLineTestMeltChip 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.2 octet string read-only
MELT chipset manufacturer hardware information Maximum length: 128 Octets
                           hwLoopLineTestMeltFirmwareVer 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.3 octet string read-only
MELT chipset manufacturer version information Maximum length: 16 Octets
                   hwLoopLineTestSysConfigPara 1.3.6.1.4.1.2011.6.21.1.1.1.9
                       hwLoopLineTestSysConfigConvertAB 1.3.6.1.4.1.2011.6.21.1.1.1.9.1 integer read-write
Indicates the polarity of A wire and B wire. Options: 1. normal(1) -default polarity of A wire and B wire 2. reverse(2) -reverse polarity of A wire and B wire 3. invalid(-1) -invalid value Default: normal(1) Enumeration: 'reverse': 2, 'invalid': -1, 'normal': 1.
                       hwLoopLineTestSysConfigCableFactor 1.3.6.1.4.1.2011.6.21.1.1.1.9.2 unsigned32 read-write
The cable-factor used to detect significant terminal device capacitance. The cable-factor ranges from 1 to 1000 units of 0.001 (Physical values are 0.001 to 1, default: 0.083).
                       hwLoopLineTestSysConfigSigCapUpperLimit 1.3.6.1.4.1.2011.6.21.1.1.1.9.3 unsigned32 read-write
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 1350nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.
                       hwLoopLineTestSysConfigSigCapLowerLimit 1.3.6.1.4.1.2011.6.21.1.1.1.9.4 unsigned32 read-write
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 250nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.
                       hwLoopLineTestSysConfigSigResistance 1.3.6.1.4.1.2011.6.21.1.1.1.9.5 unsigned32 read-write
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The resistance ranges from 10000ohm to 1000000ohm, default: 55000ohm.
                   hwONTPotsTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.10 no-access
This table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this table are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
                         hwONTPotsTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.10.1 no-access
This table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this entry are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
                             hwONTPotsTestONTIndex 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1 integer32 no-access
ONT ID.
                             hwONTPotsTestONTPstnPortIndex 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2 integer32 no-access
ONT port ID.
                             hwONTPotsTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3 integer read-only
POTS port line Test-operation type. Options: 1. stop(1) -stop a POTS port line test 2. start(2) -start a POTS port line test 3. invalid(-1) -invalid value Enumeration: 'start': 2, 'stop': 1, 'invalid': -1.
                             hwONTPotsTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4 integer read-only
POTS port line test item. Options: 1. allMLTTests(1) -outdoor connection test 2. hazardousPotential(2) -hazardous potential test 3. foreignEMF(3) -foreign electromotive force(EMF) test 4. resistiveFaults(4) -resistive faults test 5. receiverOff-hook(5) -receiver off-hook test 6. ringer(6) -ringer impedance test 7. nT1DcSignatureTest(7) -NT1 dc signature test 8. selfTest(8) -self test 9. dialToneMake-breakTest(9) -dial tone make-break test 10. subscriber-line(10) -subscriber line test 11. vendor-specificTest2(11) -vendor-specific test all results are returned in a test result message 12. vendor-specificTest3(12) -vendor-specific test all results are returned in a test result message 13. vendor-specificTest4(13) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 14. vendor-specificTest5(14) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 15. vendor-specificTest6(15) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 16. vendor-specificTest7(16) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer Enumeration: 'foreignEMF': 3, 'vendor-specificTest2': 11, 'vendor-specificTest5': 14, 'receiverOff-hook': 5, 'vendor-specificTest7': 16, 'vendor-specificTest6': 15, 'dialToneMake-breakTest': 9, 'ringer': 6, 'vendor-specificTest3': 12, 'nT1DcSignatureTest': 7, 'selfTest': 8, 'resistiveFaults': 4, 'hazardousPotential': 2, 'allMLTTests': 1, 'subscriber-line': 10, 'vendor-specificTest4': 13.
                             hwONTPotsTestBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5 integer read-only
Test mode when a line is busy. Options: 1. cancel(1) -deny a test if a line is busy 2. force(2) -forced mode Enumeration: 'cancel': 1, 'force': 2.
                             hwONTPotsTestT1Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6 integer32 read-only
Slow dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..6000 -Valid value range
                             hwONTPotsTestT2Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7 integer32 read-only
No dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..10000 -Valid value range
                             hwONTPotsTestT3Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8 integer32 read-only
Slow break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..3000 -Valid value range
                             hwONTPotsTestT4Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9 integer32 read-only
No break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..3000 -Valid value range
                             hwONTPotsTestDtmfDigit 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10 integer read-only
DTMF test number. Options: 1. zero(1) -the test number is 0 2. one(2) -the test number is 1 3. two(3) -the test number is 2 4. three(4) -the test number is 3 5. four(5) -the test number is 4 6. five(6) -the test number is 5 7. six(7) -the test number is 6 8. seven(8) -the test number is 7 9. eight(9) -the test number is 8 10. nine(10) -the test number is 9 11. symbolStar(11) -the test number is * 12. symbolSharp(12)-the test number is # 13. default(13) -use the default value (number) of the system Enumeration: 'one': 2, 'seven': 8, 'default': 13, 'six': 7, 'three': 4, 'symbolStar': 11, 'two': 3, 'four': 5, 'zero': 1, 'nine': 10, 'five': 6, 'symbolSharp': 12, 'eight': 9.
                             hwONTPotsTestDialType 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11 integer read-only
The dialling type of dialling tone test. Options: 1. dtmf(1) -dtmf type 2. pulse(2) -pulse type Enumeration: 'dtmf': 1, 'pulse': 2.
                             hwONTPotsTestDialToneFreq1 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12 integer32 read-only
The frequency1 in the dialling tone test. 0 -unused Unit: Hz
                             hwONTPotsTestDialToneFreq2 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13 integer32 read-only
The frequency2 in the dialling tone test. 0 -unused Unit: Hz
                             hwONTPotsTestDialToneFreq3 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14 integer32 read-only
The frequency3 in the dialling tone test. 0 -unused Unit: Hz
                             hwONTPotsTestDialToneEnergyThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15 integer32 read-only
The value of energy threshold in the dialling tone test. Valid value: 1. 0x00: unspecified 2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0 Unit: 0.1 dBm0
                             hwONTPotsTestIdleChannelEnergyThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16 integer32 read-only
The value of energy threshold in the dialling tone test when the line is in the idle state. Valid value: 1. 0x00: unspecified 2. 0x01-0x5A: -1 dBm0 to -90 dBm0 Unit: 1 dBm0
                             hwONTPotsTestDCHazardousVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17 integer32 read-only
The value of DC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt
                             hwONTPotsTestACHazardousVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18 integer32 read-only
The value of AC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt.
                             hwONTPotsTestDCForeignVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19 integer32 read-only
The value of DC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
                             hwONTPotsTestACForeignVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20 integer32 read-only
The value of AC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
                             hwONTPotsTestAGBGResistanceThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21 integer32 read-only
The resistance (tip to ground, ring to ground) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
                             hwONTPotsTestABResistanceThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22 integer32 read-only
The resistance (tip to ring) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
                             hwONTPotsTestRingerEquivMinThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23 integer32 read-only
Ringer equivalence minimum threshold. 0x00 -unspecified Unit: 0.01 REN
                             hwONTPotsTestRingerEquivMaxThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24 integer32 read-only
Ringer equivalence maximum threshold. 0x00 -unspecified Unit: 0.01 REN
                             hwONTPotsTestMLTResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25 integer read-only
MLT qualitative test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestHazardousVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26 integer read-only
Hazardous volt test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestEMFResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27 integer read-only
EMF test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestResistacneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28 integer read-only
Resistacne test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestOffHookResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29 integer read-only
The off-hook test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestRingerResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30 integer read-only
Ringer test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestNT1DCSignalResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31 integer read-only
NT1 DC Signal test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run Enumeration: 'failed': 1, 'passOrNotRun': 2.
                             hwONTPotsTestSelfTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32 integer read-only
Self test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run 3. notCompleted(3) -a test is not complete yet Enumeration: 'failed': 1, 'passOrNotRun': 2, 'notCompleted': 3.
                             hwONTPotsTestDrawDialToneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33 integer read-only
Draw dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passes Enumeration: 'slowDraw2': 6, 'slowDraw1': 5, 'pass1': 7, 'pass2': 8, 'couldNotDraw1': 3, 'couldNotDraw2': 4, 'notRun': 1.
                             hwONTPotsTestBreakDialToneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34 integer read-only
The break dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passes Enumeration: 'slowDraw2': 6, 'slowDraw1': 5, 'pass1': 7, 'pass2': 8, 'couldNotDraw1': 3, 'couldNotDraw2': 4, 'notRun': 1.
                             hwONTPotsTestQuietEnergyResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35 integer read-only
The quiet energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestDialToneEnergyResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36 integer read-only
The dialling tone energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails. the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopDCAGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37 integer read-only
The DC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopDCBGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38 integer read-only
The DC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run. 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopACAGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39 integer read-only
The AC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopACBGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40 integer read-only
The AC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopResistanceAGResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41 integer read-only
The A-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopResistanceBGResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42 integer read-only
The B-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopResistanceABResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43 integer read-only
The A-B (tip to ring) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestLoopRingerLoadTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44 integer read-only
The ringer load Loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported Enumeration: 'failMeasurementNotReported': 3, 'passMeasurementNotReported': 7, 'notRun': 1, 'failMeasurementReported': 4, 'passMeasurementReported': 8.
                             hwONTPotsTestDrawDialToneTimeValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45 integer32 read-only
The draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100ms.
                             hwONTPotsTestBreakDialToneTimeValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46 integer32 read-only
The break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100 ms.
                             hwONTPotsTestQuietEnergyValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47 integer32 read-only
The quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-90 : 0 dBm0 to -90 dBm0 Step: 1 dBm0
                             hwONTPotsTestDialToneEnergyValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48 integer32 read-only
The dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-255 : 0 dBm0 to -25.5 dBm0 Values above 0 dBm0 are reported as 0. Step: 0.1 dBm0
                             hwONTPotsTestLoopDCAGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49 integer32 read-only
The DC A-G(Tip-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
                             hwONTPotsTestLoopDCBGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50 integer32 read-only
The DC B-G(Ring-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
                             hwONTPotsTestLoopACAGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51 integer32 read-only
The AC A-G(Tip-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
                             hwONTPotsTestLoopACBGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52 integer32 read-only
The AC B-G(Ring-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
                             hwONTPotsTestLoopResistanceAGValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53 integer32 read-only
The A-G (tip to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
                             hwONTPotsTestLoopResistanceBGValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54 integer32 read-only
The B-G (ring to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
                             hwONTPotsTestLoopResistanceABValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55 integer32 read-only
The A-B (tip to ring) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
                             hwONTPotsTestLoopRingerLoadTestValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56 integer32 read-only
The ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult is failMeasurementReported(4) or passMeasurementReported(8). Unit: 0.1 REN.
                             hwONTPotsTestSubscriberLineTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57 integer read-only
The subscriber line test result. Options: 1. normal(1) -subscriber line test normal 2. acCurrentAbnormal(12) -AC current abnormal 3. dcCurrentAbnormal(13) -DC current abnormal 4. loopCurrentAbnormal(14) -loop current abnormal 5. loopResistanceAbnormal(15) -loop resistance abnormal 6. insulatingResistanceAbnormal(16) -insulating resistance abnormal 7. capacitanceAbnormal(17) -capacitance abnormal 8. impedanceAbnormal(18) -impedance abnormal 9. insulatingNotGood(22) -insulating not good 10. brokenLines(23) -broken lines 11. lineMixing(24) -line mixing 12. connectedToGround(25) -connected to ground 13. abLinereversal(26) -ABLine reversal 14. lineLeaking(27) -line leaking 15. phoneDisconnect(28) -phone disconnect 16. testTimeout(29) -test is time out 17. testFailed(30) -test failed 18. invalid(-1) -a test does not run Enumeration: 'acCurrentAbnormal': 12, 'impedanceAbnormal': 18, 'lineMixing': 24, 'insulatingResistanceAbnormal': 16, 'normal': 1, 'capacitanceAbnormal': 17, 'loopCurrentAbnormal': 14, 'testTimeout': 29, 'abLinereversal': 26, 'lineLeaking': 27, 'phoneDisconnect': 28, 'invalid': -1, 'insulatingNotGood': 22, 'connectedToGround': 25, 'loopResistanceAbnormal': 15, 'testFailed': 30, 'dcCurrentAbnormal': 13, 'brokenLines': 23.
                             hwONTPotsTestLoopDCABVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58 integer32 read-only
The DC A-B (tip-Ring) volt result of subscriber line test. Unit: volt.
                             hwONTPotsTestLoopACABVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59 integer32 read-only
The AC A-B (Tip-Ring) volt result of subscriber line test. Unit: volt.
                             hwONTPotsTestLoopAGCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60 integer32 read-only
The A->G (Tip-Ground) capacitance result of subscriber line test. Unit: nF
                             hwONTPotsTestLoopBGCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61 integer32 read-only
The B->G (Ring-Ground) capacitance result of subscriber line test. Unit: nF
                             hwONTPotsTestLoopABCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62 integer32 read-only
The A->B (Tip-Ring) capacitance result of subscriber line test. Unit: nF
                   hwPortTestingListOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.11 no-access
This table is used to query the ports under a test by board. The indexes of this table are hwFrameIndex and hwSlotIndex.
                         hwPortTestingListOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.11.1 no-access
This table is used to query the ports under a test by board. The indexes of this entry are hwFrameIndex and hwSlotIndex.
                             hwMeltTestingPortList 1.3.6.1.4.1.2011.6.21.1.1.1.11.1.1 bits read-only
List of ports under a MELT test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a MELT test. For example, if port 8 is under a MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0. Bits: 'port58': 58, 'port59': 59, 'port54': 54, 'port55': 55, 'port56': 56, 'port39': 39, 'port50': 50, 'port51': 51, 'port52': 52, 'port53': 53, 'port18': 18, 'port19': 19, 'port62': 62, 'port38': 38, 'port37': 37, 'port10': 10, 'port11': 11, 'port12': 12, 'port13': 13, 'port14': 14, 'port15': 15, 'port16': 16, 'port17': 17, 'port47': 47, 'port35': 35, 'port32': 32, 'port34': 34, 'port33': 33, 'port30': 30, 'port8': 8, 'port9': 9, 'port6': 6, 'port7': 7, 'port4': 4, 'port5': 5, 'port2': 2, 'port3': 3, 'port0': 0, 'port1': 1, 'port61': 61, 'port60': 60, 'port49': 49, 'port48': 48, 'port43': 43, 'port42': 42, 'port41': 41, 'port40': 40, 'port31': 31, 'port46': 46, 'port45': 45, 'port44': 44, 'port29': 29, 'port28': 28, 'port25': 25, 'port24': 24, 'port27': 27, 'port26': 26, 'port21': 21, 'port20': 20, 'port23': 23, 'port22': 22, 'port57': 57, 'port63': 63, 'port36': 36.
                             hwSearchToneTestingPortList 1.3.6.1.4.1.2011.6.21.1.1.1.11.1.2 bits read-only
List of ports under a searching tone test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a searching tone test. For example, if port 8 is under MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0. Bits: 'port58': 58, 'port59': 59, 'port54': 54, 'port55': 55, 'port56': 56, 'port39': 39, 'port50': 50, 'port51': 51, 'port52': 52, 'port53': 53, 'port18': 18, 'port19': 19, 'port62': 62, 'port38': 38, 'port37': 37, 'port10': 10, 'port11': 11, 'port12': 12, 'port13': 13, 'port14': 14, 'port15': 15, 'port16': 16, 'port17': 17, 'port47': 47, 'port35': 35, 'port32': 32, 'port34': 34, 'port33': 33, 'port30': 30, 'port8': 8, 'port9': 9, 'port6': 6, 'port7': 7, 'port4': 4, 'port5': 5, 'port2': 2, 'port3': 3, 'port0': 0, 'port1': 1, 'port61': 61, 'port60': 60, 'port49': 49, 'port48': 48, 'port43': 43, 'port42': 42, 'port41': 41, 'port40': 40, 'port31': 31, 'port46': 46, 'port45': 45, 'port44': 44, 'port29': 29, 'port28': 28, 'port25': 25, 'port24': 24, 'port27': 27, 'port26': 26, 'port21': 21, 'port20': 20, 'port23': 23, 'port22': 22, 'port57': 57, 'port63': 63, 'port36': 36.
                   hwWettingCurrentOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.12 no-access
This table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this table is ifindex.
                         hwWettingCurrentOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.12.1 no-access
This table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this entry is ifindex.
                             hwWettingCurrentOprStatus 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.1 integer read-write
Wetting Current operation type. Options: 1. enabled(1) -enable a wetting current port 2. disabled(2) -disable a wetting current port 3. invalid(-1) -invalid value enabled(1) and disabled(2) options are available in the set operation. enabled(1), disabled(2) and invalid(-1) options are available in the get operation. Enumeration: 'disabled': 2, 'enabled': 1, 'invalid': -1.
                             hwWettingCurrentOprWorkingVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.2 integer32 read-write
Indicates the working voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 90 Unit: volt
                             hwWettingCurrentOprMaximumVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.3 integer32 read-write
Indicates the maximum voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 30 Unit: volt
                             hwWettingCurrentOprSlope 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.4 integer32 read-write
Indicates the slope of a wetting current port. Options: 1. -1 -Invalid value 2. 200..20000 -Valid value range Default: 200 Unit: volt per second
           hwTestCommonTraps 1.3.6.1.4.1.2011.6.21.1.2
               hwTestCommonTrapVbOids 1.3.6.1.4.1.2011.6.21.1.2.1
                   hwTestCommonVbOidsReason 1.3.6.1.4.1.2011.6.21.1.2.1.2
                       hwTestClearedReason 1.3.6.1.4.1.2011.6.21.1.2.1.2.1 integer no-access
Definition of the test-canceling reasons. Options: 1. testBoardFail(1) -the test-canceling reason is testBoardFail 2. testedBoardFail(2) -the test-canceling reason is testedBoardFail 3. userCmd(3) -the test-canceling reason is userCmd 4. switchOver(4) -the test-canceling reason is switchOver 5. anotherMainBoardIsTesting(5) -the test-canceling reason is anotherMainBoardIsTesting 6. unknowError(255) -the test-canceling reason is unknowError Enumeration: 'switchOver': 4, 'anotherMainBoardIsTesting': 5, 'testedBoardFail': 2, 'userCmd': 3, 'unknowError': 255, 'testBoardFail': 1.
                       hwTestRingSrcAlarmReason 1.3.6.1.4.1.2011.6.21.1.2.1.2.2 integer no-access
Definition of the ringing source alarms. Options: 1. testRingSrcFail(1) -the ringing source alarm is testRingSrcFail 2. testRingSrcRestore(2) -the ringing source alarm is testRingSrcRestore Enumeration: 'testRingSrcRestore': 2, 'testRingSrcFail': 1.
                   hwTestCommonRequestID 1.3.6.1.4.1.2011.6.21.1.2.1.3 integer32 no-access
NMS request ID.
               hwTestCommonAlarmTraps 1.3.6.1.4.1.2011.6.21.1.2.2
                   hwTestCommonAlarmTrapsOIDs 1.3.6.1.4.1.2011.6.21.1.2.2.0
                       hwTestRingSrcFailTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.1
The btss ring source failed trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS doesn't work) Troubleshooting suggestions: (1) Check the BTSS board; (2) Reset the BTSS board; (3) Replace the BTSS board. This trap will send when the btss ring source failed.
                       hwTestRingSrcRestoreTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.2
Test ringing source restore trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS is normal) The advice: none. This trap will send when test ringing source restore.
                       hwTestAutoClearedTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.3
Trap of test automatically cancelled: 1: hwTestBoardIfIndex; 2: hwTestBoardStatusTestedBoardIfIndex; 3: hwTestClearedReason. This trap will send when the test automatically cancelled.
               hwTestCommonGeneralTraps 1.3.6.1.4.1.2011.6.21.1.2.3
                   hwTestCommonGeneralTrapsOIDs 1.3.6.1.4.1.2011.6.21.1.2.3.0
                       hwLoopLineTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.1
This trap will be sent when a loop-line test finished successfully. The trap shows the result of the loop-line test. 1. hwLoopLineTestRequestID, 2. hwLoopLineTestStatus, 3. hwLoopLineTestConclusion, 4. hwLoopLineTestACAG, 5. hwLoopLineTestACBG, 6. hwLoopLineTestACAB, 7. hwLoopLineTestDCAG, 8. hwLoopLineTestDCBG, 9. hwLoopLineTestDCAB, 10. hwLoopLineTestRAG, 11. hwLoopLineTestRBG, 12. hwLoopLineTestRAB, 13. hwLoopLineTestCapAG, 14. hwLoopLineTestCapBG, 15. hwLoopLineTestCapAB, 16. hwLoopLineTestLR, 17. hwLoopLineTestRABResPole, 18. hwLoopLineTestMSocket, 19. hwLoopLineTestPPAResult, 19. hwLoopLineTestIfIndex, 20. hwLoopLineTestMoreDataFlag
                       hwMeterTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.2
Meter test result trap: 1: hwMeterTestStatus. This trap will send when meter test result return.
                       hwTestBoardDiagnoseTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.3
Test board self-test result trap: 1: hwTestBoardDiagnoseTestResult; 2: hwTestBoardDiagnoseTestRAM; 3: hwTestBoardDiagnoseTestVoltage; 4: hwTestBoardDiagnoseTestResistance; 5: hwTestBoardDiagnoseTestSignal; 6: hwTestBoardDiagnoseTestDTMF; 7: hwTestBoardDiagnoseTestRing; 8: hwTestBoardDiagnoseTestOnOffHook; 9: hwTestBoardDiagnoseTestPole; 10: hwTestBoardDiagnoseTestISDNU; 11: hwTestBoardDiagnoseTestBitErrCode; 12: hwTestBoardDiagnoseTestCapacitance. This trap will send when the test board self-test result return.
                       hwTestBoardStatusQueryTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.4
Test board status query result trap: 1: hwTestBoardStatusQueryResult; 2: hwTestBoardStatusQueryVersion; 3: hwTestBoardStatusQueryTestItem; 4: hwTestBoardStatusTestedBoardIfIndex. This trap will send when the test board status query result return.
                       hwTestOntPotsTestResultTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.5
This trap indicates that a POTS port line test finished successfully, and shows the result of the line test. This trap will send when a POTS port line test finished successfully.
                       hwTestCommonMeltTestResultTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.6
This trap indicates that MELT test finished successfully, and show the result of the melt test This trap will send when the MELT test finished successfully.
                       hwTestCommonMeltTestFaileTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.7
This trap indicates that MELT test fails. This trap will send when the MELT test failed.