HPOV-NNM-MIB: View SNMP OID List / Download MIB
VENDOR: HEWLETT-PACKARD
Home | MIB: HPOV-NNM-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hp | 1.3.6.1.4.1.11 | |||
nm | 1.3.6.1.4.1.11.2 | |||
openView | 1.3.6.1.4.1.11.2.17 | |||
hpOpenView | 1.3.6.1.4.1.11.2.17.1 |
General management information used within the HP OpenView Network Node Manager product. This object identifier also serves as the OpenView Enterprise ID for SNMPv1 Traps. |
||
hpOVNNMTraps | 1.3.6.1.4.1.11.2.17.1.0 | |||
hpOVMessageTrap | 1.3.6.1.4.1.11.2.17.1.0.58916872 |
This special event can be generated by a user to display an event message in the event browser. It assumes the message is in the third variable. To send a message with a popup notification, use the OV_Popup_Message event. On UNIX, see the trapd.conf(4) manpage for a discussion on how to set up the parameters to send this event, and a description of the parameters. On Windows, see the trapd.conf reference page in the help file. The data passed with the event is openViewSourceId: The ID of application sending the event openViewSourceName: The source of the event, if available openViewData: The string to display openViewSeverity: The severity of the event On UNIX, see the trapd.conf(4) manpage for complete details. On Windows, see the trapd.conf reference page in the help file. |
||
openViewTrapVars | 1.3.6.1.4.1.11.2.17.2 | |||
openViewSourceId | 1.3.6.1.4.1.11.2.17.2.1 | integer | no-access |
The identifier of the software generating the trap/event. This number is used by HP OpenView software when it sends an event to the OpenView event system. It identifies which software component sent the event. |
openViewSourceName | 1.3.6.1.4.1.11.2.17.2.2 | ovtextstring | no-access |
The source of the event (may not be the machine upon which the event was generated). This string is used by HP OpenView software when it sends an event. It identifies for which node the event is generated. |
openViewObjectId | 1.3.6.1.4.1.11.2.17.2.3 | displaystring | no-access |
The OpenView Windows object identifier associated with the source of the trap/event. |
openViewData | 1.3.6.1.4.1.11.2.17.2.4 | octet string | no-access |
Any miscellaneous data sent with an OpenView trap/event. |
openViewSeverity | 1.3.6.1.4.1.11.2.17.2.5 | ovtextstring | no-access |
The OpenView event severity associated with the trap/event. |
openViewCategory | 1.3.6.1.4.1.11.2.17.2.6 | ovtextstring | no-access |
The OpenView event category associated with the trap/event. |
openViewFilter | 1.3.6.1.4.1.11.2.17.2.7 | displaystring | no-access |
The event filter for an application connecting to the OpenView event system. |
openViewEntity | 1.3.6.1.4.1.11.2.17.2.8 | ovtextstring | no-access |
The entity (string name) of an application connecting to the OpenView event system. |
openViewAddress | 1.3.6.1.4.1.11.2.17.2.9 | displaystring | no-access |
The IP address of the node from where an application is connecting to the OpenView event system. |
openViewPid | 1.3.6.1.4.1.11.2.17.2.10 | displaystring | no-access |
The process ID of an application connecting to the OpenView event system. |
openViewCmipManagedObjectClass | 1.3.6.1.4.1.11.2.17.2.11 | displaystring | no-access |
A cmisEventReport managedObjectClass. Only valid when running with the HP OpenView DM product. |
openViewCmipEventTime | 1.3.6.1.4.1.11.2.17.2.12 | displaystring | no-access |
A cmisEventReport eventTime. Only valid when running with the HP OpenView DM product. |
openViewCmipEventType | 1.3.6.1.4.1.11.2.17.2.13 | displaystring | no-access |
A cmisEventReport eventType. Only valid when running with the HP OpenView DM product. |
openViewCmipEventInfo | 1.3.6.1.4.1.11.2.17.2.14 | displaystring | no-access |
A cmisEventReport eventInfo. Only valid when running with the HP OpenView DM product. |
openViewCmipManagedObjectInstanceId | 1.3.6.1.4.1.11.2.17.2.15 | displaystring | no-access |
A cmisEventReport managedObjectInstance. Only valid when running with the HP OpenView DM product. |
openViewEventUUID | 1.3.6.1.4.1.11.2.17.2.16 | octet string | no-access |
An OpenView Event UUID which uniquely identifies an event. |
openViewEcsCorrelateEvUUID | 1.3.6.1.4.1.11.2.17.2.17 | displaystring | no-access |
If an OpenView event contains this var-bind, it indicates to the Event Correlation System that the event should be correlated with the event whose UUID is the value of this var-bind. If the var-bind is missing or has a zero length value, then no event correlation occurs. |
openViewEcsNodeImportance | 1.3.6.1.4.1.11.2.17.2.18 | displaystring | no-access |
If an OpenView event contains this var-bind, it indicates to the Event Correlation System the importance of the node from an event correlation perspective. In situations where the ECS system would normally suppress an event, it may choose not to suppress it if the node is very important (e.g. an important server node). The integral value of this MIB object may evolve over time. For now, non-integral values are invalid, a value of zero indicates that the node is a regular node and a non-zero value indicates that the node is an important node. |