Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hp | 1.3.6.1.4.1.11 | |||
nm | 1.3.6.1.4.1.11.2 | |||
hpnsa | 1.3.6.1.4.1.11.2.23 | |||
hpnsaECC | 1.3.6.1.4.1.11.2.23.6 | |||
hpnsaRemoteAssist | 1.3.6.1.4.1.11.2.23.8 | |||
hPECCMemory11 | 1.3.6.1.4.1.11.2.23.60.4360 |
ECC error corrected in memory module |
||
hPECCMemory12 | 1.3.6.1.4.1.11.2.23.60.4361 |
Uncorrectable multi-bit ECC error has occurred in memory module |
||
hPECCMemory13 | 1.3.6.1.4.1.11.2.23.60.4363 |
Repeated ECC error corrected in memory module |
||
hPECCMemory14 | 1.3.6.1.4.1.11.2.23.60.4364 |
ECC memory module is operating outside of acceptable margins |
||
hPECCMemory15 | 1.3.6.1.4.1.11.2.23.60.4365 |
Memory Mirroring switched to Slave Set |
||
hPECCMemory16 | 1.3.6.1.4.1.11.2.23.60.4366 |
Faulty row switched to Hot Spare row |
||
hPECCMemory2 | 1.3.6.1.4.1.11.2.23.60.24353 |
A single-bit error has been corrected in one of the memory modules. |
||
hPECCMemory3 | 1.3.6.1.4.1.11.2.23.60.24354 |
Predictive failure in a memory module |
||
hPECCMemory7 | 1.3.6.1.4.1.11.2.23.60.24357 |
A Multiple-bit error has occurred in one of the memory modules |
||
hPECCMemory9 | 1.3.6.1.4.1.11.2.23.60.24359 |
Single-bit repeated error |
||
rAVoltage1 | 1.3.6.1.4.1.11.2.23.80.109 |
The server has lost the power completely. |
||
rAVoltage2 | 1.3.6.1.4.1.11.2.23.80.111 |
Voltage measured in the server has gone outside of -12V Upper Threshold. |
||
rAVoltage3 | 1.3.6.1.4.1.11.2.23.80.113 |
Voltage measured in the server has gone outside of +3.3V Upper Threshold. |
||
rAVoltage4 | 1.3.6.1.4.1.11.2.23.80.114 |
Voltage measured in the server has gone outside of +5V Upper Threshold. |
||
rAVoltage5 | 1.3.6.1.4.1.11.2.23.80.115 |
Voltage measured in the server has gone outside of +12V Upper Threshold. |
||
rAVoltage6 | 1.3.6.1.4.1.11.2.23.80.121 |
Voltage measured in the server has gone outside of -12V Lower Threshold. |
||
rAVoltage10 | 1.3.6.1.4.1.11.2.23.80.122 |
The HP Remote Assistant Card's battery charging circuit is bad. |
||
rAVoltage7 | 1.3.6.1.4.1.11.2.23.80.123 |
Voltage measured in the server has gone outside of +3.3V Lower Threshold. |
||
rAVoltage8 | 1.3.6.1.4.1.11.2.23.80.124 |
Voltage measured in the server has gone outside of +5V Lower Threshold. |
||
rAVoltage9 | 1.3.6.1.4.1.11.2.23.80.125 |
Voltage measured in the server has gone outside of +12V Lower Threshold. |
||
rATemp1 | 1.3.6.1.4.1.11.2.23.80.211 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured warning threshold. |
||
rATemp2 | 1.3.6.1.4.1.11.2.23.80.221 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured threshold and the server has been automatically shut down. |
||
rATemp4 | 1.3.6.1.4.1.11.2.23.80.231 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured Graceful Shutdown threshold value by 5 degrees C and the server has been automatically shut down. |
||
rAOther1 | 1.3.6.1.4.1.11.2.23.80.401 |
An administrator has logged in to the HP Remote Assistant Card. |
||
rAOther3 | 1.3.6.1.4.1.11.2.23.80.402 |
An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP Remote Assistant Card within a 5-minute period of time. |
||
rAOther5 | 1.3.6.1.4.1.11.2.23.80.403 |
The HP Remote Assistant Card's battery charging circuit is bad. |
||
rAOther6 | 1.3.6.1.4.1.11.2.23.80.404 |
The HP Remote Assistant Card has been shut down. |
||
rAOther20 | 1.3.6.1.4.1.11.2.23.80.405 |
A remote user disconnected from the HP RA or Remote Control card. |
||
rAOther21 | 1.3.6.1.4.1.11.2.23.80.406 |
An administrator has been automatically disconnected from the HP Remote Assistant board. The administrator was inactive for more than five minutes. |
||
rAOther23 | 1.3.6.1.4.1.11.2.23.80.407 |
An administrator has been prematurely disconnected from the Remote Assistant board. |
||
rAOther25 | 1.3.6.1.4.1.11.2.23.80.408 |
An administrator failed to connect to the HP Remote Assistant board on a dialback |
||
rAASR1 | 1.3.6.1.4.1.11.2.23.80.501 |
ASR has stopped notifying the HP Remote Assistant Card that the system is running correctly (the server probably hung or crashed). |
||
rAASR2 | 1.3.6.1.4.1.11.2.23.80.502 |
The HP Remote Assistant card has restarted the server due to the NOS being hung. |
||
rAASR3 | 1.3.6.1.4.1.11.2.23.80.503 |
The Automatic Server Restart software has been enabled by the Remote Assistant ASR timer. |
||
rAASR4 | 1.3.6.1.4.1.11.2.23.80.504 |
The HP Remote Assistant Automatic Server Restart timer has been disabled. |
||
rAOther7 | 1.3.6.1.4.1.11.2.23.80.601 |
An administrator has executed a remote |
||
rAOther9 | 1.3.6.1.4.1.11.2.23.80.602 |
An administrator has executed a remote power cycle on the server via the HP Remote Assistant Card. |
||
rAOther12 | 1.3.6.1.4.1.11.2.23.80.603 |
An administrator has executed a remote power down of the server via the HP Remote Assistant Card. |
||
rAOther18 | 1.3.6.1.4.1.11.2.23.80.701 |
The server's BIOS has successfully initialized the HP Remote Assistant Card during the boot process. |
||
rABusUsage1 | 1.3.6.1.4.1.11.2.23.80.800 |
The 5-minute average EISA bus utilization has exceeded the configured threshold. |
||
rAOther19 | 1.3.6.1.4.1.11.2.23.80.900 |
An administrator has executed Test Page from the HP Remote Assistant Configuration Utility. |
||
rAOther29 | 1.3.6.1.4.1.11.2.23.80.901 |
The HP Remote Assistant modem was unable to connect to the TAP paging service modem. |
||
rAOther31 | 1.3.6.1.4.1.11.2.23.80.902 |
HP Remote Assistant was unable to connect with the TAP paging service. |
||
rAOther32 | 1.3.6.1.4.1.11.2.23.80.903 |
HP Remote Assistant was unable to log on to the TAP paging service. |
||
rAOther35 | 1.3.6.1.4.1.11.2.23.80.904 |
The HP Remote Assistant pager message was rejected |
||
rAOther10 | 1.3.6.1.4.1.11.2.23.80.1602 |
A remote user has executed a remote power cycle on the server via the HP RA or Remote Control. |
||
rAOther13 | 1.3.6.1.4.1.11.2.23.80.1603 |
A remote user has executed a remote power down of the server via the HP RA or Remote Control card. |
||
rATemp3 | 1.3.6.1.4.1.11.2.23.80.2221 |
The server temperature or voltage levels measured by the remote management hardware has exceeded the configured threshold. The server has been automatically shut down. |
||
rAOther2 | 1.3.6.1.4.1.11.2.23.80.2401 |
A remote user has logged in to the HP RA or Remote Control card. |
||
rAOther4 | 1.3.6.1.4.1.11.2.23.80.2402 |
An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP RA or Remote Control card. |
||
rAOther22 | 1.3.6.1.4.1.11.2.23.80.2406 |
A remote user has been automatically disconnected from the HP RA or Remote Control card, because of inactivity. |
||
rAOther24 | 1.3.6.1.4.1.11.2.23.80.2407 |
A remote user has been prematurely disconnected from the HP RA or Remote Control card. |
||
rAOther26 | 1.3.6.1.4.1.11.2.23.80.2408 |
A remote user failed to connect to the HP RA or Remote Control on a dialback |
||
rAOther8 | 1.3.6.1.4.1.11.2.23.80.2601 |
An administrator has executed a remote |
||
rAOther17 | 1.3.6.1.4.1.11.2.23.80.2604 |
A remote user has executed a remote graceful shutdown of the server via the HP RA or Remote Control card. |
||
rAOther30 | 1.3.6.1.4.1.11.2.23.80.2901 |
The HP RA or Remote Control modem was unable to connect to the TAP paging service modem. |
||
rAOther33 | 1.3.6.1.4.1.11.2.23.80.2902 |
The HP RA or Remote Control was unable to connect to the TAP paging service. |
||
rAOther34 | 1.3.6.1.4.1.11.2.23.80.2903 |
The HP RA or Remote Control was unable to log on to the TAP paging service. |
||
rAOther36 | 1.3.6.1.4.1.11.2.23.80.2904 |
The HP RA or Remote Control pager message was rejected by the TAP paging service. |
||
rAOther37 | 1.3.6.1.4.1.11.2.23.80.2905 |
The HP RA or Remote Control email notification message was not sent correctly. |
||
rAOther38 | 1.3.6.1.4.1.11.2.23.80.2906 |
A modem error has been detected on the remote management card. |
||
rAOther39 | 1.3.6.1.4.1.11.2.23.80.2907 |
TopTools Remote Control Card memory test started |
||
rAOther40 | 1.3.6.1.4.1.11.2.23.80.2908 |
TopTools Remote Control Card memory test completed |
||
rAOther41 | 1.3.6.1.4.1.11.2.23.80.2909 |
TopTools Remote Control Card memory test stopped by user |
||
rAOther42 | 1.3.6.1.4.1.11.2.23.80.2910 |
TopTools Remote Control Card memory test error |
||
rAOther43 | 1.3.6.1.4.1.11.2.23.80.2911 |
TopTools Remote Control Card started |
||
rAOther44 | 1.3.6.1.4.1.11.2.23.80.2912 |
TopTools Remote Control Card detects a serious internal error that prevents normal operation of the card |
||
rAOther45 | 1.3.6.1.4.1.11.2.23.80.2913 |
The firmware on the TopTools Remote Control has been updated |
||
rAOther46 | 1.3.6.1.4.1.11.2.23.80.2914 |
The TopTools Remote Control backup battery has discharged to a level where it will not be able to power the card |
||
rAOther47 | 1.3.6.1.4.1.11.2.23.80.2915 |
The battery on the TopTools Remote Control card is disconnected |
||
rAOther48 | 1.3.6.1.4.1.11.2.23.80.2916 |
Remote Control Card: DHCP has assigned a new IP address |
||
rAOther27 | 1.3.6.1.4.1.11.2.23.80.3408 |
Integrated RA configuration reset to defaults |
||
rAOther11 | 1.3.6.1.4.1.11.2.23.80.3602 |
A remote user has executed a remote hard reset on the server via the HP RA or Remote Control. |
||
rAOther14 | 1.3.6.1.4.1.11.2.23.80.3603 |
A remote user has executed a remote power up of the server via the HP RA or Remote Control card. |
||
rAOther28 | 1.3.6.1.4.1.11.2.23.80.4408 |
TopTools Remote Control card configuration was corrupted and has been restored to default settings. |
||
rAOther15 | 1.3.6.1.4.1.11.2.23.80.4603 |
Automatic power shutdown due to critical condition. |
||
rAOther16 | 1.3.6.1.4.1.11.2.23.80.5603 |
Front panel power down. |
||
hPFWUpdate1 | 1.3.6.1.4.1.11.2.230.101 |
Front Panel Controller firmware updated |
||
hPFWUpdate2 | 1.3.6.1.4.1.11.2.230.102 |
Primary Hot Swap Cage Controller firmware updated |
||
hPFWUpdate3 | 1.3.6.1.4.1.11.2.230.103 |
Secondary Hot Swap Cage Controller firmware updated |
||
hPFWUpdate4 | 1.3.6.1.4.1.11.2.230.104 |
NetServer Management Controller firmware updated |
||
hPFWUpdate5 | 1.3.6.1.4.1.11.2.230.105 |
CPU Management Controller firmware updated |
||
storageCap1 | 1.3.6.1.4.1.11.2.230.4096 |
Volume Storage Capacity has exceeded the warning threshold level. |
||
storageCap3 | 1.3.6.1.4.1.11.2.230.4097 |
Volume Storage Capacity has exceeded the minor threshold level. |
||
storageCap5 | 1.3.6.1.4.1.11.2.230.4098 |
Volume Storage Capacity has exceeded the major threshold level. |
||
systemHW1 | 1.3.6.1.4.1.11.2.230.4356 |
Post Error has occurred. |
||
hPDiskSystem1 | 1.3.6.1.4.1.11.2.230.8210 |
The Defect List Threshold has been exceeded. |
||
hPRaid1 | 1.3.6.1.4.1.11.2.230.8609 |
HPDA Controller: Cache Error |
||
hPRaid3 | 1.3.6.1.4.1.11.2.230.8625 |
HPDA Logical Drive: Critical |
||
hPRaid4 | 1.3.6.1.4.1.11.2.230.8626 |
HPDA Logical Drive Not Available |
||
hPRaid5 | 1.3.6.1.4.1.11.2.230.8641 |
HPDA Hot Spare:Failed |
||
hPRaid7 | 1.3.6.1.4.1.11.2.230.8642 |
HPDA Hot Spare Succeeded |
||
hPRaid8 | 1.3.6.1.4.1.11.2.230.8657 |
HPDA Hard Disk Failed |
||
hPRaid10 | 1.3.6.1.4.1.11.2.230.8673 |
HPDA Threshold Exceeded: Parity |
||
hPRaid12 | 1.3.6.1.4.1.11.2.230.8674 |
HPDA Threshold Exceeded: Soft Errors |
||
hPRaid14 | 1.3.6.1.4.1.11.2.230.8675 |
HPDA Threshold Exceeded: Hardware Errors |
||
hPRaid16 | 1.3.6.1.4.1.11.2.230.8676 |
HPDA Threshold Exceeded: Miscellaneous Errors |
||
hPRaid18 | 1.3.6.1.4.1.11.2.230.8677 |
HPDA Controller: NVRAM Age |
||
redundantPower1 | 1.3.6.1.4.1.11.2.230.9101 |
The Redundant Power Supply module is not operating properly, but there is no power supply module hardware failure. |
||
redundantPower2 | 1.3.6.1.4.1.11.2.230.9103 |
Indicates a failure with the AC power source that is connected to one of the redundant power supply units. |
||
redundantPower4 | 1.3.6.1.4.1.11.2.230.9105 |
Indicates that one of the redundant power supply modules is not in normal operating condition. |
||
redundantPower5 | 1.3.6.1.4.1.11.2.230.9106 |
Indicates that one of the redundant power supply modules is in over temperature protection mode. |
||
redundantPower7 | 1.3.6.1.4.1.11.2.230.9107 |
Indicates that one of the redundant power supply modules has been physically removed from the HP NetServer Power Supply Subsystem. |
||
redundantPower8 | 1.3.6.1.4.1.11.2.230.9108 |
Indicates that one of the redundant power supply modules has been physically inserted into the HP NetServer Power Supply Subsystem. |
||
redundantPower9 | 1.3.6.1.4.1.11.2.230.9109 |
Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. |
||
redundantPower11 | 1.3.6.1.4.1.11.2.230.9110 |
Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. |
||
redundantPower13 | 1.3.6.1.4.1.11.2.230.9111 |
Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the emergency temperature level. |
||
redundantPower14 | 1.3.6.1.4.1.11.2.230.9112 |
Power System failure A/C Lost |
||
redundantPower15 | 1.3.6.1.4.1.11.2.230.9113 |
The Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation or is having problems powering up or down. |
||
redundantPower37 | 1.3.6.1.4.1.11.2.230.9114 |
Power Supply Subsystem soft failure |
||
temperature1 | 1.3.6.1.4.1.11.2.230.12288 |
Server temperature monitor cannot read temperature data. |
||
temperature2 | 1.3.6.1.4.1.11.2.230.12289 |
Server temperature has exceeded the warning temperature threshold. |
||
temperature3 | 1.3.6.1.4.1.11.2.230.12290 |
Server temperature has exceeded the emergency temperature threshold. |
||
networkCard1 | 1.3.6.1.4.1.11.2.230.16385 |
The total number of packets with receive errors has exceeded the threshold. |
||
networkCard5 | 1.3.6.1.4.1.11.2.230.16386 |
The total number of packets with transmit errors has exceeded the threshold. |
||
networkCard9 | 1.3.6.1.4.1.11.2.230.16387 |
The total number of LAN Adapter reset errors has exceeded the threshold. |
||
networkCard13 | 1.3.6.1.4.1.11.2.230.16388 |
The total number of alignment and CRC errors has exceeded the threshold. |
||
networkCard17 | 1.3.6.1.4.1.11.2.230.16389 |
The total number of giant frame packets has exceeded the threshold. |
||
networkCard21 | 1.3.6.1.4.1.11.2.230.16390 |
The total number of packets with length less than the required minimum length has exceeded the threshold. |
||
networkCard25 | 1.3.6.1.4.1.11.2.230.16391 |
The total number of late collision errors has exceeded the threshold (the network is too large). |
||
networkCard29 | 1.3.6.1.4.1.11.2.230.16392 |
The total number of colliding packets has exceeded the threshold (the network is too busy). |
||
networkCard33 | 1.3.6.1.4.1.11.2.230.16393 |
The total number of carrier sense errors has exceeded the threshold. |
||
networkCard37 | 1.3.6.1.4.1.11.2.230.16394 |
The total number of adapter deferrals has exceeded the threshold (the network is forever busy). |
||
networkCard41 | 1.3.6.1.4.1.11.2.230.16395 |
The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. |
||
networkCard45 | 1.3.6.1.4.1.11.2.230.16396 |
The total number of Receive Overflow errors has exceeded the threshold. |
||
networkCard49 | 1.3.6.1.4.1.11.2.230.16397 |
LAN adapter utilization count has exceeded the threshold. |
||
networkCard53 | 1.3.6.1.4.1.11.2.230.16398 |
The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. |
||
networkCard55 | 1.3.6.1.4.1.11.2.230.16399 |
There possibly is a dataflow problem with your HP LAN adapter. |
||
networkCard56 | 1.3.6.1.4.1.11.2.230.16400 |
The HP LAN adapter driver did not receive a transmit complete interrupt. |
||
networkCard57 | 1.3.6.1.4.1.11.2.230.16401 |
There possibly is a dataflow problem with your HP LAN adapter. |
||
networkCard58 | 1.3.6.1.4.1.11.2.230.16402 |
There is a dataflow problem with your HP LAN adapter - receive interrupts are being generated, but no receive packets are being present. |
||
networkCard59 | 1.3.6.1.4.1.11.2.230.16403 |
There possibly is a problem with your HP LAN adapter - it generates too many buffer pointer errors. |
||
networkCard60 | 1.3.6.1.4.1.11.2.230.16404 |
There possibly is a problem with your HP LAN adapter - DMA timed out while transmitting or receiving a packet. |
||
networkCard61 | 1.3.6.1.4.1.11.2.230.16405 |
The HP LAN adapter is transmitting faster than the media can handle. |
||
networkCard62 | 1.3.6.1.4.1.11.2.230.16406 |
The number of buffer fragments has exceeded the maximum number allowed by the network protocol in your HP LAN adapter. |
||
networkCard63 | 1.3.6.1.4.1.11.2.230.16407 |
The total number of errors due to requests of an ECB being denied has exceeded the threshold. |
||
networkCard64 | 1.3.6.1.4.1.11.2.230.16408 |
There possibly is a problem with your HP LAN adapter running in bus master mode. |
||
networkCard65 | 1.3.6.1.4.1.11.2.230.16418 |
The active NIC in a redundant group has failed. The standby NIC has taken over. |
||
networkCard67 | 1.3.6.1.4.1.11.2.230.16419 |
A previously failed NIC in a redundant group has become operational. |
||
networkCard69 | 1.3.6.1.4.1.11.2.230.16420 |
The standby NIC in a redundant group has failed. |
||
networkCard71 | 1.3.6.1.4.1.11.2.230.16421 |
All NICs (active and standby) in a redundant group have failed. |
||
systemHW6 | 1.3.6.1.4.1.11.2.230.20528 |
Parity error has been detected in parity memory |
||
systemHW8 | 1.3.6.1.4.1.11.2.230.20544 |
One of the bus masters caused a bus timeout |
||
systemHW7 | 1.3.6.1.4.1.11.2.230.20545 |
IPMB Protocol Error |
||
systemHW73 | 1.3.6.1.4.1.11.2.230.20546 |
NOS memory dump initiated |
||
systemHW9 | 1.3.6.1.4.1.11.2.230.20560 |
I/0 channel check activated by device in EISA slot caused an error |
||
systemHW11 | 1.3.6.1.4.1.11.2.230.20576 |
Software NMI has been generated |
||
systemHW12 | 1.3.6.1.4.1.11.2.230.20577 |
Uncorrectable Bus Error |
||
systemHW64 | 1.3.6.1.4.1.11.2.230.20578 |
Cache Protocol and Parity error |
||
systemHW65 | 1.3.6.1.4.1.11.2.230.20579 |
Correctable data error |
||
systemHW13 | 1.3.6.1.4.1.11.2.230.20592 |
Memory size has been adjusted during the Power-On-Self-Test during the last boot |
||
systemHW14 | 1.3.6.1.4.1.11.2.230.20624 |
Parity error has occurred on a transfer to/from a device on one of the PCI buses |
||
systemHW16 | 1.3.6.1.4.1.11.2.230.20640 |
System error has occurred in the PCI subsystem |
||
systemHW21 | 1.3.6.1.4.1.11.2.230.20656 |
Processor or Terminator (#) not detected |
||
systemHW18 | 1.3.6.1.4.1.11.2.230.20657 |
An uncorrectable Processor problem was detected. |
||
systemHW19 | 1.3.6.1.4.1.11.2.230.20658 |
Processor (#) Disabled |
||
systemHW59 | 1.3.6.1.4.1.11.2.230.20659 |
The CPU processor module is currently functioning properly, but it is no longer operating within acceptable margins |
||
systemHW20 | 1.3.6.1.4.1.11.2.230.20660 |
Processor or Terminator Card Not Detected |
||
systemHW22 | 1.3.6.1.4.1.11.2.230.20661 |
Processor Internal Error |
||
systemHW23 | 1.3.6.1.4.1.11.2.230.20662 |
Processor Thermal Trip Failure |
||
systemHW24 | 1.3.6.1.4.1.11.2.230.20663 |
Processor failed internal self test |
||
systemHW25 | 1.3.6.1.4.1.11.2.230.20664 |
Processor hung during POST |
||
systemHW26 | 1.3.6.1.4.1.11.2.230.20665 |
Processor startup/initialization failed |
||
systemHW60 | 1.3.6.1.4.1.11.2.230.20666 |
PCI Hot Plug fault deasserted |
||
systemHW61 | 1.3.6.1.4.1.11.2.230.20667 |
PCI Hot Plug Powered On |
||
systemHW62 | 1.3.6.1.4.1.11.2.230.20668 |
PCI Hot Plug fault asserted |
||
systemHW63 | 1.3.6.1.4.1.11.2.230.20669 |
PCI Hot Plug Powered off |
||
systemHW27 | 1.3.6.1.4.1.11.2.230.20670 |
Multiple Fan Failure |
||
systemHW79 | 1.3.6.1.4.1.11.2.230.20671 |
Configuration error in a processor slot |
||
systemHW28 | 1.3.6.1.4.1.11.2.230.20672 |
Timeout of failsafe timer has occurred |
||
systemHW81s | 1.3.6.1.4.1.11.2.230.20673 |
CPU thermal trip |
||
systemHW82s | 1.3.6.1.4.1.11.2.230.20674 |
CPU hot warning |
||
systemHW80s | 1.3.6.1.4.1.11.2.230.20675 |
CPU internal error |
||
systemHW83 | 1.3.6.1.4.1.11.2.230.20676 |
CPU mismatch |
||
systemHW58 | 1.3.6.1.4.1.11.2.230.20680 |
Front Panel Button Violation |
||
systemHW29 | 1.3.6.1.4.1.11.2.230.20704 |
Error logging for a specific error has been disabled due to too many errors of that kind in a short time period |
||
systemHW43 | 1.3.6.1.4.1.11.2.230.20736 |
An event of warning severity has occurred in the system. For example, chassis door has been opened |
||
systemHW44 | 1.3.6.1.4.1.11.2.230.20737 |
An event of critical severity has occurred in the system. For example, both system fans have failed |
||
voltage2 | 1.3.6.1.4.1.11.2.230.20738 |
Fatal voltage threshold on one of the system voltage sensors has been exceeded. Voltage sensors are +12V, +5V, -12V, +3.3V to PCI, +3.3V to Processor |
||
voltage1 | 1.3.6.1.4.1.11.2.230.20739 |
Warning voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to Processor |
||
systemHW10 | 1.3.6.1.4.1.11.2.230.20740 |
Voltage utilization warning |
||
systemHW11s | 1.3.6.1.4.1.11.2.230.20741 |
Voltage utilization error |
||
aSR1 | 1.3.6.1.4.1.11.2.230.20752 |
Server has been restarted after the system watchdog timer has timed out due to NOS being hung |
||
aSR2 | 1.3.6.1.4.1.11.2.230.20753 |
OS Watchdog Shutdown |
||
aSR3 | 1.3.6.1.4.1.11.2.230.20754 |
OS Watchdog poweroff |
||
systemFW3 | 1.3.6.1.4.1.11.2.230.20755 |
OS Boot Complete |
||
systemFW2 | 1.3.6.1.4.1.11.2.230.20756 |
System Firmware Boot Start |
||
systemFW4 | 1.3.6.1.4.1.11.2.230.20757 |
Machine Check Initiated |
||
systemFW1 | 1.3.6.1.4.1.11.2.230.20758 |
Generic trap for Critical or Fatal type E0 event from system firmware |
||
fibreChannel5 | 1.3.6.1.4.1.11.2.230.20759 |
The Fibre Channel Adapter is Online |
||
fibreChannel6 | 1.3.6.1.4.1.11.2.230.20760 |
The Fibre Channel Adapter is Offline |
||
systemHW30 | 1.3.6.1.4.1.11.2.230.20800 |
EISA Configuration Utility has altered system configuration |
||
systemHW48 | 1.3.6.1.4.1.11.2.230.20832 |
The hardware eventlog has been cleared. |
||
systemHW49 | 1.3.6.1.4.1.11.2.230.20833 |
An unrecognized HW log event was detected. |
||
systemHW50 | 1.3.6.1.4.1.11.2.230.20848 |
The system has been rebooted. |
||
systemHW51 | 1.3.6.1.4.1.11.2.230.22528 |
The Processor in the indicated slot has been disabled by the BIOS. |
||
systemHW57 | 1.3.6.1.4.1.11.2.230.22544 |
A single or multiple ECC Error has been detected on the P6 bus. |
||
hPFan7 | 1.3.6.1.4.1.11.2.230.22576 |
One of the fans in the Processor/PCI fan tray stopped. |
||
hPFan8 | 1.3.6.1.4.1.11.2.230.22593 |
Two or more of the fans in the Processor/PCI Fan Tray have stopped or have been removed. |
||
hPFan9 | 1.3.6.1.4.1.11.2.230.22608 |
Fan problem in Processor/PCI Fan Tray has been corrected. |
||
aSR8 | 1.3.6.1.4.1.11.2.230.22624 |
The System has been reset by the microcontroller firmware because watchdog timer expired. |
||
hPFan10 | 1.3.6.1.4.1.11.2.230.22640 |
One of the fans in the Memory Fan Tray stopped. |
||
systemHW52 | 1.3.6.1.4.1.11.2.230.22651 |
A user has halted the system with the NMI switch on the front panel. |
||
hPFan11 | 1.3.6.1.4.1.11.2.230.22657 |
Two or more of the fans in the Memory Fan Tray have stopped or been removed. |
||
hPFan12 | 1.3.6.1.4.1.11.2.230.22672 |
Fan problem in the Memory Fan Tray has been corrected. |
||
systemHW53 | 1.3.6.1.4.1.11.2.230.22688 |
Previously disabled Processor has been reinstalled. |
||
redundantPower16 | 1.3.6.1.4.1.11.2.230.22705 |
Temperature alert on designated Power Supply. |
||
redundantPower18 | 1.3.6.1.4.1.11.2.230.22706 |
Fan failure on designated Power Supply. |
||
redundantPower20 | 1.3.6.1.4.1.11.2.230.22707 |
Voltage error on designated Power Supply. |
||
redundantPower21 | 1.3.6.1.4.1.11.2.230.22708 |
Fan speed-up on designated Power Supply. |
||
redundantPower23 | 1.3.6.1.4.1.11.2.230.22709 |
A power supply's 3.3 volt supply has gone bad |
||
redundantPower24 | 1.3.6.1.4.1.11.2.230.22710 |
A power supply's 5 volt supply has gone bad |
||
redundantPower25 | 1.3.6.1.4.1.11.2.230.22711 |
A power supply's 12 volt supply has gone bad |
||
redundantPower26 | 1.3.6.1.4.1.11.2.230.22712 |
A power supply's -12 volt supply has gone bad |
||
redundantPower27 | 1.3.6.1.4.1.11.2.230.22720 |
Indicated Power Supply has been removed or is not connected properly. |
||
redundantPower28 | 1.3.6.1.4.1.11.2.230.22736 |
The indicated Power Supply has been inserted. |
||
systemHW54 | 1.3.6.1.4.1.11.2.230.22752 |
The system has been reset because Control Board detected a critical error. |
||
systemHW55 | 1.3.6.1.4.1.11.2.230.22768 |
The system has been power-cycled because Control Board detected a critical error. |
||
systemHW56 | 1.3.6.1.4.1.11.2.230.22785 |
The Processor Card is missing or not properly terminated in indicated processor module. |
||
hPEnvironment7 | 1.3.6.1.4.1.11.2.230.22801 |
Voltage Regulating Module (VRM) on the indicated processor module had failed. |
||
storageCap2 | 1.3.6.1.4.1.11.2.230.24096 |
Volume Storage Capacity has exceeded the warning threshold level. |
||
storageCap4 | 1.3.6.1.4.1.11.2.230.24097 |
Volume Storage Capacity has exceeded the minor threshold level. |
||
storageCap6 | 1.3.6.1.4.1.11.2.230.24098 |
Volume Storage Capacity has exceeded the major threshold level. |
||
systemHW2 | 1.3.6.1.4.1.11.2.230.24356 |
Post Error has occurred. |
||
systemHW3 | 1.3.6.1.4.1.11.2.230.24358 |
Post Error has occurred. |
||
temperature4 | 1.3.6.1.4.1.11.2.230.24449 |
Hot Swap Cage : Temperature monitor error occurred |
||
temperature5 | 1.3.6.1.4.1.11.2.230.24451 |
Hot Swap Cage : Warning temperature exceeded |
||
temperature6 | 1.3.6.1.4.1.11.2.230.24452 |
Hot Swap Cage : Emergency temperature exceeded! |
||
systemHW32 | 1.3.6.1.4.1.11.2.230.24453 |
Power connection failure in one of the devices in the hot swap cage |
||
systemHW34 | 1.3.6.1.4.1.11.2.230.24454 |
A device has been removed from the hot swap cage |
||
systemHW35 | 1.3.6.1.4.1.11.2.230.24455 |
A device has been inserted into the hot swap cage |
||
systemHW45 | 1.3.6.1.4.1.11.2.230.24456 |
Event log is getting full. |
||
hPEnvironment1 | 1.3.6.1.4.1.11.2.230.25000 |
One of the voltage sensors crossed its lower non-critical threshold. |
||
hPEnvironment2 | 1.3.6.1.4.1.11.2.230.25001 |
One of the voltage sensors crossed its lower critical threshold. |
||
hPEnvironment3 | 1.3.6.1.4.1.11.2.230.25002 |
One of the voltage sensors crossed its lower non-recoverable threshold. |
||
hPEnvironment4 | 1.3.6.1.4.1.11.2.230.25003 |
One of the voltage sensors crossed its upper non-critical threshold. |
||
hPEnvironment5 | 1.3.6.1.4.1.11.2.230.25004 |
One of the voltage sensors crossed its upper critical threshold. |
||
hPEnvironment6 | 1.3.6.1.4.1.11.2.230.25005 |
One of the voltage sensors crossed its upper non-recoverable threshold. |
||
systemHW7s | 1.3.6.1.4.1.11.2.230.25006 |
VRM failure |
||
hPTemperature1 | 1.3.6.1.4.1.11.2.230.25007 |
One of the temperature sensors crossed its lower non-critical threshold. |
||
hPTemperature2 | 1.3.6.1.4.1.11.2.230.25008 |
One of the temperature sensors crossed its lower critical threshold. |
||
hPTemperature3 | 1.3.6.1.4.1.11.2.230.25009 |
One of the temperature sensors crossed its lower non-recoverable threshold. |
||
hPTemperature4 | 1.3.6.1.4.1.11.2.230.25010 |
One of the temperature sensors crossed its upper non-critical threshold. |
||
hPTemperature5 | 1.3.6.1.4.1.11.2.230.25011 |
One of the temperature sensors crossed its upper critical threshold. |
||
hPTemperature6 | 1.3.6.1.4.1.11.2.230.25012 |
One of the temperature sensors crossed its upper non-recoverable threshold. |
||
hPFan1 | 1.3.6.1.4.1.11.2.230.25013 |
One of the fan sensors crossed its lower non-critical threshold. |
||
hPFan2 | 1.3.6.1.4.1.11.2.230.25014 |
One of the fan sensors crossed its lower critical threshold. |
||
hPFan3 | 1.3.6.1.4.1.11.2.230.25015 |
One of the fan sensors crossed its lower non-recoverable threshold. |
||
hPFan4 | 1.3.6.1.4.1.11.2.230.25016 |
One of the fan sensors crossed its upper non-critical threshold. |
||
hPFan5 | 1.3.6.1.4.1.11.2.230.25017 |
One of the fan sensors crossed its upper critical threshold. |
||
hPFan6 | 1.3.6.1.4.1.11.2.230.25018 |
One of the fan sensors crossed its upper non-recoverable threshold. |
||
hPChassis1 | 1.3.6.1.4.1.11.2.230.25019 |
The chassis has been opened. |
||
hPChassis2 | 1.3.6.1.4.1.11.2.230.25020 |
I/O area open |
||
hPChassis3 | 1.3.6.1.4.1.11.2.230.25021 |
Processor area open |
||
systemHW80 | 1.3.6.1.4.1.11.2.230.25022 |
Battery cycles have gone beyond the upper non-critical range |
||
systemHW81 | 1.3.6.1.4.1.11.2.230.25023 |
Battery cycles have gone beyond the upper critical range |
||
systemHW82 | 1.3.6.1.4.1.11.2.230.25024 |
Battery cycles have gone beyond the upper non-recoverable range |
||
hPFan13 | 1.3.6.1.4.1.11.2.230.25025 |
A system fan module error has occurred |
||
hPFan14 | 1.3.6.1.4.1.11.2.230.25026 |
A system fan module error has occurred |
||
hPFan15 | 1.3.6.1.4.1.11.2.230.25027 |
Fan module failure |
||
hPFan16 | 1.3.6.1.4.1.11.2.230.25028 |
Fan module failure |
||
systemHW84 | 1.3.6.1.4.1.11.2.230.25780 |
Unrecoverable chipset error has occurred in system board . |
||
hPRaid2 | 1.3.6.1.4.1.11.2.230.28609 |
HPDA Controller: Cache Error |
||
hPRaid6 | 1.3.6.1.4.1.11.2.230.28641 |
HPDA Hot Spare:Failed |
||
hPRaid9 | 1.3.6.1.4.1.11.2.230.28657 |
HPDA Hard Disk Failed |
||
hPRaid11 | 1.3.6.1.4.1.11.2.230.28673 |
HPDA Threshold Exceeded: Parity |
||
hPRaid13 | 1.3.6.1.4.1.11.2.230.28674 |
HPDA Threshold Exceeded: Soft Errors |
||
hPRaid15 | 1.3.6.1.4.1.11.2.230.28675 |
HPDA Threshold Exceeded: Hardware Errors |
||
hPRaid17 | 1.3.6.1.4.1.11.2.230.28676 |
HPDA Threshold Exceeded: Miscellaneous Errors |
||
hPRaid19 | 1.3.6.1.4.1.11.2.230.28677 |
HPDA Controller: NVRAM Age |
||
redundantPower29 | 1.3.6.1.4.1.11.2.230.29101 |
Indicated Power Supply has been removed. |
||
redundantPower30 | 1.3.6.1.4.1.11.2.230.29102 |
The indicated Power Supply has been inserted. |
||
redundantPower31 | 1.3.6.1.4.1.11.2.230.29103 |
The indicated Power Supply Unit power has failed. |
||
redundantPower33 | 1.3.6.1.4.1.11.2.230.29104 |
Power supply subsystem redundancy gained. |
||
redundantPower34 | 1.3.6.1.4.1.11.2.230.29105 |
Power supply sunsystem redundancy lost. |
||
redundantPower35 | 1.3.6.1.4.1.11.2.230.29106 |
The server Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation. |
||
redundantPower36 | 1.3.6.1.4.1.11.2.230.29107 |
The server Power Supply Subsystem has fewer than the required number of Power Supply Units installed for normal operation. |
||
redundantPower32 | 1.3.6.1.4.1.11.2.230.29109 |
Predictive failure/alert in power supply |
||
systemHW4 | 1.3.6.1.4.1.11.2.230.34356 |
System boot (POST Complete). |
||
systemHW5 | 1.3.6.1.4.1.11.2.230.34357 |
Netserver Management Controller started |
||
systemHW46 | 1.3.6.1.4.1.11.2.230.34456 |
Event log cleared |
||
systemHW47 | 1.3.6.1.4.1.11.2.230.44456 |
SDR area cleared |
||
systemHW83s | 1.3.6.1.4.1.11.2.230.44457 |
FRU internal use area cleared |
||
systemHW100 | 1.3.6.1.4.1.11.2.230.53001 |
SMART predictive failure detected |
||
systemHW33 | 1.3.6.1.4.1.11.2.230.54453 |
system Voltage failure |
||
systemHW36 | 1.3.6.1.4.1.11.2.230.54454 |
A SCSI cable has been removed from the hot swap cage. |
||
systemHW37 | 1.3.6.1.4.1.11.2.230.54455 |
A SCSI cable was attached to hot swap cage. |
||
systemHW38 | 1.3.6.1.4.1.11.2.230.54456 |
A SCSI terminator has been removed from the hot swap cage. |
||
systemHW39 | 1.3.6.1.4.1.11.2.230.54457 |
A SCSI terminator has been attached in the hot swap cage. |
||
systemHW74 | 1.3.6.1.4.1.11.2.230.54460 |
SCSI Duplex Board has been removed |
||
systemHW75 | 1.3.6.1.4.1.11.2.230.54461 |
SCSI Duplex Board has been inserted |
||
systemHW78 | 1.3.6.1.4.1.11.2.230.54464 |
SCSI Bus Type has changed |
||
systemHW76 | 1.3.6.1.4.1.11.2.230.54465 |
Normal ACPI server shutdown |
||
systemHW77 | 1.3.6.1.4.1.11.2.230.54466 |
ACPI hardware failure |
||
networkCard2 | 1.3.6.1.4.1.11.2.230.116385 |
The total number of packets with receive errors has exceeded the threshold. |
||
networkCard6 | 1.3.6.1.4.1.11.2.230.116386 |
The total number of packets with transmit errors has exceeded the threshold. |
||
networkCard10 | 1.3.6.1.4.1.11.2.230.116387 |
The total number of LAN Adapter reset errors has exceeded the threshold. |
||
networkCard14 | 1.3.6.1.4.1.11.2.230.116388 |
The total number of alignment and CRC errors has exceeded the threshold. |
||
networkCard18 | 1.3.6.1.4.1.11.2.230.116389 |
The total number of giant frame packets has exceeded the threshold. |
||
networkCard22 | 1.3.6.1.4.1.11.2.230.116390 |
The total number of packets with length less than the required minimum length has exceeded the threshold. |
||
networkCard26 | 1.3.6.1.4.1.11.2.230.116391 |
The total number of late collision errors has exceeded the threshold (the network is too large). |
||
networkCard30 | 1.3.6.1.4.1.11.2.230.116392 |
The total number of colliding packets has exceeded the threshold (the network is too busy). |
||
networkCard34 | 1.3.6.1.4.1.11.2.230.116393 |
The total number of carrier sense errors has exceeded the threshold. |
||
networkCard38 | 1.3.6.1.4.1.11.2.230.116394 |
The total number of adapter deferrals has exceeded the threshold (the network is forever busy). |
||
networkCard42 | 1.3.6.1.4.1.11.2.230.116395 |
The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. |
||
networkCard46 | 1.3.6.1.4.1.11.2.230.116396 |
The total number of Receive Overflow errors has exceeded the threshold. |
||
networkCard50 | 1.3.6.1.4.1.11.2.230.116397 |
LAN adapter utilization count has exceeded the threshold. |
||
networkCard54 | 1.3.6.1.4.1.11.2.230.116398 |
The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. |
||
networkCard66 | 1.3.6.1.4.1.11.2.230.116418 |
The active NIC in a redundant group has failed. The standby NIC has taken over. |
||
networkCard68 | 1.3.6.1.4.1.11.2.230.116419 |
A previously failed NIC in a redundant group has become operational. |
||
networkCard70 | 1.3.6.1.4.1.11.2.230.116420 |
The standby NIC in a redundant group has failed. |
||
networkCard72 | 1.3.6.1.4.1.11.2.230.116421 |
All NICs (active and standby) in a redundant group have failed. |
||
redundantPower3 | 1.3.6.1.4.1.11.2.230.209103 |
Indicates a failure with the AC power source that is connected to one of the redundant power supply units. |
||
redundantPower6 | 1.3.6.1.4.1.11.2.230.209106 |
Indicates that one of the redundant power supply modules is in over temperature protection mode. |
||
redundantPower10 | 1.3.6.1.4.1.11.2.230.209109 |
Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. |
||
redundantPower12 | 1.3.6.1.4.1.11.2.230.209110 |
Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. |
||
networkCard3 | 1.3.6.1.4.1.11.2.230.216385 |
The total number of packets with receive errors has exceeded the threshold. |
||
networkCard7 | 1.3.6.1.4.1.11.2.230.216386 |
The total number of packets with transmit errors has exceeded the threshold. |
||
networkCard11 | 1.3.6.1.4.1.11.2.230.216387 |
The total number of LAN Adapter reset errors has exceeded the threshold. |
||
networkCard15 | 1.3.6.1.4.1.11.2.230.216388 |
The total number of alignment and CRC errors has exceeded the threshold. |
||
networkCard19 | 1.3.6.1.4.1.11.2.230.216389 |
The total number of giant frame packets has exceeded the threshold. |
||
networkCard23 | 1.3.6.1.4.1.11.2.230.216390 |
The total number of packets with length less than the required minimum length has exceeded the threshold. |
||
networkCard27 | 1.3.6.1.4.1.11.2.230.216391 |
The total number of late collision errors has exceeded the threshold (the network is too large). |
||
networkCard31 | 1.3.6.1.4.1.11.2.230.216392 |
The total number of colliding packets has exceeded the threshold (the network is too busy). |
||
networkCard35 | 1.3.6.1.4.1.11.2.230.216393 |
The total number of carrier sense errors has exceeded the threshold. |
||
networkCard39 | 1.3.6.1.4.1.11.2.230.216394 |
The total number of adapter deferrals has exceeded the threshold (the network is forever busy). |
||
networkCard43 | 1.3.6.1.4.1.11.2.230.216395 |
The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. |
||
networkCard47 | 1.3.6.1.4.1.11.2.230.216396 |
The total number of Receive Overflow errors has exceeded the threshold. |
||
networkCard51 | 1.3.6.1.4.1.11.2.230.216397 |
LAN adapter utilization count has exceeded the threshold. |
||
systemHW10s | 1.3.6.1.4.1.11.2.230.220560 |
I/0 channel check activated by device in EISA slot caused an error |
||
hPECCMemory10 | 1.3.6.1.4.1.11.2.230.220592 |
System memory size reduced due to error in memory slot |
||
systemHW15 | 1.3.6.1.4.1.11.2.230.220624 |
Parity error has occurred on a transfer to or from a device on one of the PCI buses |
||
systemHW17 | 1.3.6.1.4.1.11.2.230.220640 |
System error has occurred in the PCI subsystem |
||
aSR4 | 1.3.6.1.4.1.11.2.230.220752 |
Server has been restarted after the system watchdog timer has timed out due to NOS being hung |
||
systemHW31 | 1.3.6.1.4.1.11.2.230.220800 |
Configuration Utility has altered system configuration |
||
redundantPower17 | 1.3.6.1.4.1.11.2.230.222705 |
Temperature alert on designated Power Supply. |
||
redundantPower19 | 1.3.6.1.4.1.11.2.230.222706 |
Fan failure on designated Power Supply. |
||
redundantPower22 | 1.3.6.1.4.1.11.2.230.222708 |
Fan speed-up on designated Power Supply. |
||
temperature7 | 1.3.6.1.4.1.11.2.230.224449 |
Hot Swap Cage : Temperature monitor error occurred |
||
temperature8 | 1.3.6.1.4.1.11.2.230.224451 |
Hot Swap Cage : Warning temperature exceeded |
||
temperature9 | 1.3.6.1.4.1.11.2.230.224452 |
Hot Swap Cage : Emergency temperature exceeded! |
||
systemHW40 | 1.3.6.1.4.1.11.2.230.224453 |
Power connection failure in one of the devices in the hot swap cage |
||
systemHW41 | 1.3.6.1.4.1.11.2.230.224454 |
A device has been removed from the hot swap cage |
||
systemHW42 | 1.3.6.1.4.1.11.2.230.224455 |
A device has been inserted into the hot swap cage |
||
systemHW67 | 1.3.6.1.4.1.11.2.230.254454 |
A SCSI cable has been removed from the hot swap cage. |
||
systemHW68 | 1.3.6.1.4.1.11.2.230.254455 |
A SCSI cable was attached to the hot swap cage. |
||
systemHW69 | 1.3.6.1.4.1.11.2.230.254456 |
A SCSI terminator has been removed from the hot swap cage. |
||
systemHW70 | 1.3.6.1.4.1.11.2.230.254457 |
A SCSI terminator has been attached in the hot swap cage. |
||
networkCard4 | 1.3.6.1.4.1.11.2.230.316385 |
The total number of packets with receive errors has exceeded the threshold. |
||
networkCard8 | 1.3.6.1.4.1.11.2.230.316386 |
The total number of packets with transmit errors has exceeded the threshold. |
||
networkCard12 | 1.3.6.1.4.1.11.2.230.316387 |
The total number of LAN Adapter reset errors has exceeded the threshold. |
||
networkCard16 | 1.3.6.1.4.1.11.2.230.316388 |
The total number of alignment and CRC errors has exceeded the threshold. |
||
networkCard20 | 1.3.6.1.4.1.11.2.230.316389 |
The total number of giant frame packets has exceeded the threshold. |
||
networkCard24 | 1.3.6.1.4.1.11.2.230.316390 |
The total number of packets with length less than the required minimum length has exceeded the threshold. |
||
networkCard28 | 1.3.6.1.4.1.11.2.230.316391 |
The total number of late collision errors has exceeded the threshold (the network is too large). |
||
networkCard32 | 1.3.6.1.4.1.11.2.230.316392 |
The total number of colliding packets has exceeded the threshold (the network is too busy). |
||
networkCard36 | 1.3.6.1.4.1.11.2.230.316393 |
The total number of carrier sense errors has exceeded the threshold. |
||
networkCard40 | 1.3.6.1.4.1.11.2.230.316394 |
The total number of adapter deferrals has exceeded the threshold (the network is forever busy). |
||
networkCard44 | 1.3.6.1.4.1.11.2.230.316395 |
The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. |
||
networkCard48 | 1.3.6.1.4.1.11.2.230.316396 |
The total number of Receive Overflow errors has exceeded the threshold. |
||
networkCard52 | 1.3.6.1.4.1.11.2.230.316397 |
LAN adapter utilization count has exceeded the threshold. |
||
aSR5 | 1.3.6.1.4.1.11.2.230.320752 |
Server has not been restarted after the system watchdog timer has timed out due to NOS being hung |
||
systemHW71 | 1.3.6.1.4.1.11.2.230.324454 |
A drive has been removed from the hot swap cage |
||
systemHW72 | 1.3.6.1.4.1.11.2.230.324455 |
A drive has been inserted into the hot swap cage |
||
aSR6 | 1.3.6.1.4.1.11.2.230.420752 |
Server has been powered down after the system watchdog timer has timed out due to NOS being hung |
||
aSR7 | 1.3.6.1.4.1.11.2.230.520752 |
Server has been power cycled after the system watchdog timer has timed out due to NOS being hung |
||
hpnr | 1.3.6.1.4.1.16 | |||
hpNetRAID | 1.3.6.1.4.1.16.1 | |||
hpNetRaidMib | 1.3.6.1.4.1.16.1.1 | |||
raidTraps | 1.3.6.1.4.1.16.1.1.200 | |||
adaptec | 1.3.6.1.4.1.795 | |||
storagemanagement | 1.3.6.1.4.1.795.2 | |||
cyclone | 1.3.6.1.4.1.795.2.5 | |||
cycTraps | 1.3.6.1.4.1.795.2.5.9000 | |||
sCSISmart22 | 1.3.6.1.4.1.795.2.50.126 |
Aspi: initializing |
||
adaptecRaid | 1.3.6.1.4.1.795.3 | |||
adaptecNm | 1.3.6.1.4.1.795.4 | |||
adaptecNmScsiStatus | 1.3.6.1.4.1.795.4.1 | |||
adaptecSCSI1 | 1.3.6.1.4.1.795.4.10.8193 |
Device Database has been corrupted. |
||
adaptecSCSI3 | 1.3.6.1.4.1.795.4.10.8194 |
SCSI Status agent was unloaded from a NetWare Server. |
||
adaptecSCSI5 | 1.3.6.1.4.1.795.4.10.8196 |
One of the SCSI HBAs can no longer be detected by the SCSI Status agent. |
||
adaptecSCSI7 | 1.3.6.1.4.1.795.4.10.8197 |
A Host Adapter which has failed, has become accessible again. |
||
adaptecSCSI9 | 1.3.6.1.4.1.795.4.10.8198 |
A new SCSI Host Bus Adapter has been discovered or device database has been cleared. |
||
adaptecSCSI11 | 1.3.6.1.4.1.795.4.10.8199 |
One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. |
||
adaptecSCSI13 | 1.3.6.1.4.1.795.4.10.8200 |
A SCSI device which has failed, has become accessible again. |
||
adaptecSCSI15 | 1.3.6.1.4.1.795.4.10.8201 |
A new SCSI device has been discovered. |
||
adaptecSCSI17 | 1.3.6.1.4.1.795.4.10.8205 |
The SCSI Status agent detected that the Host Bus Adapter has been changed. |
||
adaptecSCSI21 | 1.3.6.1.4.1.795.4.10.8206 |
The SCSI Status agent detected that a SCSI device installed on the server has been changed. |
||
adaptecSCSI19 | 1.3.6.1.4.1.795.4.10.8208 |
The SCSI Status agent sent a request to an HBA and the request never completed. |
||
adaptecSCSI23 | 1.3.6.1.4.1.795.4.10.8209 |
The SCSI Status agent sent a request to a SCSI device and the request never completed. |
||
adaptecSCSI2 | 1.3.6.1.4.1.795.4.10.18193 |
Device Database has been corrupted. |
||
adaptecSCSI4 | 1.3.6.1.4.1.795.4.10.18194 |
SCSI Status agent was unloaded from a NetWare Server. |
||
adaptecSCSI6 | 1.3.6.1.4.1.795.4.10.18196 |
One of the SCSI HBAs can no longer be detected by the SCSI Status agent. |
||
adaptecSCSI8 | 1.3.6.1.4.1.795.4.10.18197 |
A Host Adapter which has failed, has become accessible again. |
||
adaptecSCSI10 | 1.3.6.1.4.1.795.4.10.18198 |
A new SCSI Host Bus Adapter has been discovered or device database has been cleared. |
||
adaptecSCSI12 | 1.3.6.1.4.1.795.4.10.18199 |
One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. |
||
adaptecSCSI14 | 1.3.6.1.4.1.795.4.10.18200 |
A SCSI device which has failed, has become accessible again. |
||
adaptecSCSI16 | 1.3.6.1.4.1.795.4.10.18201 |
A new SCSI device has been discovered. |
||
adaptecSCSI18 | 1.3.6.1.4.1.795.4.10.18205 |
The SCSI Status agent detected that the Host Bus Adapter has been changed. |
||
adaptecSCSI22 | 1.3.6.1.4.1.795.4.10.18206 |
The SCSI Status agent detected that a SCSI device installed on the server has been changed. |
||
adaptecSCSI20 | 1.3.6.1.4.1.795.4.10.18208 |
The SCSI Status agent sent a request to an HBA and the request never completed. |
||
adaptecSCSI24 | 1.3.6.1.4.1.795.4.10.18209 |
The SCSI Status agent sent a request to a SCSI device and the request never completed. |
||
raidproducts | 1.3.6.1.4.1.795.10 | |||
aac | 1.3.6.1.4.1.795.10.1 | |||
aac_hpn | 1.3.6.1.4.1.795.10.1.50 | |||
symbios | 1.3.6.1.4.1.1123 | |||
coloradosprings | 1.3.6.1.4.1.1123.3 | |||
scsi | 1.3.6.1.4.1.1123.3.1 | |||
symc8xx | 1.3.6.1.4.1.1123.3.1.2 | |||
symTrap | 1.3.6.1.4.1.1123.3.1.2.2 | |||
eMylex1 | 1.3.6.1.4.1.1608 | |||
eMylex2 | 1.3.6.1.4.1.1608.1 | |||
eMylex3 | 1.3.6.1.4.1.1608.1.1 | |||
eMylex4 | 1.3.6.1.4.1.1608.1.1.1 | |||
eMylex5 | 1.3.6.1.4.1.1608.1.1.1.9 | |||
eMylexRaidEventInformation | 1.3.6.1.4.1.1608.1.1.1.9.1 | |||
dmtfStd | 1.3.6.1.4.1.1608.1.1.1.9.1.1 | |||
dmtfComponents | 1.3.6.1.4.1.1608.1.1.1.9.1.1.1 | |||
dmtfGroups | 1.3.6.1.4.1.1608.1.1.1.9.1.1.1.1 |