HPNSATRAP-MIB: View SNMP OID List / Download MIB
VENDOR: HEWLETT-PACKARD
Home | MIB: HPNSATRAP-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hp | 1.3.6.1.4.1.11 | |||
nm | 1.3.6.1.4.1.11.2 | |||
hpnsa | 1.3.6.1.4.1.11.2.23 | |||
hpnsaECC | 1.3.6.1.4.1.11.2.23.6 | |||
hpnsaRemoteAssist | 1.3.6.1.4.1.11.2.23.8 | |||
hpnsaEccErrorCorrected | 1.3.6.1.4.1.11.2.23.60.4353 |
An ECC single-bit error has been corrected in one of the memory modules |
||
hpnsaEccSBEOverflow | 1.3.6.1.4.1.11.2.23.60.4354 |
Error logging for ECC single-bit errors has been disabled due to too many SBE's detected in a short time period |
||
hpnsaEccMemoryResize | 1.3.6.1.4.1.11.2.23.60.4355 |
ECC Memory size has been adjusted during the Power-On-Self-Test during the last boot due to a failed memory module |
||
hpnsaEccMultiBitError | 1.3.6.1.4.1.11.2.23.60.4357 |
An ECC double-bit error has occurred in one of the memory modules |
||
hpnsaEccMultiBitErrorOverflow | 1.3.6.1.4.1.11.2.23.60.4358 |
Error logging for ECC multiple-bit errors has been disabled due to too many MBE's detected in a short time period |
||
hpnsaRAVoltServerPowerFailure | 1.3.6.1.4.1.11.2.23.80.109 |
The server has lost the power completely. |
||
hpnsaRAVoltMinus12VUpper | 1.3.6.1.4.1.11.2.23.80.111 |
Voltage measured in the server has gone outside of -12V Upper Threshold. |
||
hpnsaRAVoltPlus3VUpper | 1.3.6.1.4.1.11.2.23.80.113 |
Voltage measured in the server has gone outside of +3.3V Upper Threshold. |
||
hpnsaRAVoltPlus5VUpper | 1.3.6.1.4.1.11.2.23.80.114 |
Voltage measured in the server has gone outside of +5V Upper Threshold. |
||
hpnsaRAVoltPlus12VUpper | 1.3.6.1.4.1.11.2.23.80.115 |
Voltage measured in the server has gone outside of +12V Upper Threshold. |
||
hpnsaRAVoltMinus12VLower | 1.3.6.1.4.1.11.2.23.80.121 |
Voltage measured in the server has gone outside of -12V Lower Threshold. |
||
hpnsaRAVoltBatteryLower | 1.3.6.1.4.1.11.2.23.80.122 |
The HP Remote Assistant Card's battery charging circuit is bad. |
||
hpnsaRAVoltPlus3VLower | 1.3.6.1.4.1.11.2.23.80.123 |
Voltage measured in the server has gone outside of +3.3V Lower Threshold. |
||
hpnsaRAVoltPlus5VLower | 1.3.6.1.4.1.11.2.23.80.124 |
Voltage measured in the server has gone outside of +5V Lower Threshold. |
||
hpnsaRAVoltPlus12VLower | 1.3.6.1.4.1.11.2.23.80.125 |
Voltage measured in the server has gone outside of +12V Lower Threshold. |
||
hpnsaRATempWarning | 1.3.6.1.4.1.11.2.23.80.211 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured warning threshold. |
||
hpnsaRATempShutdown | 1.3.6.1.4.1.11.2.23.80.221 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured threshold and the server has been automatically shut down. |
||
hpnsaRATempCritical | 1.3.6.1.4.1.11.2.23.80.231 |
The server temperature measured on the HP Remote Assistant Card has exceeded the configured Graceful Shutdown threshold value by 5 degrees C and the server has been automatically shut down. |
||
hpnsaRASuccessfulLogin | 1.3.6.1.4.1.11.2.23.80.401 |
An administrator has logged in to the HP Remote Assistant Card. |
||
hpnsaRAIllegalLogin | 1.3.6.1.4.1.11.2.23.80.402 |
An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP Remote Assistant Card within a 5-minute period of time. |
||
hpnsaRALowBatteryCharge | 1.3.6.1.4.1.11.2.23.80.403 |
The HP Remote Assistant Card's battery charging circuit is bad. |
||
hpnsaRABoardShutDown | 1.3.6.1.4.1.11.2.23.80.404 |
The HP Remote Assistant Card has been shut down. |
||
hpnsaRAAdminstratorLogout | 1.3.6.1.4.1.11.2.23.80.405 |
An administrator disconnected from the HP Remote Assistant board. |
||
hpnsaRAAdministratorAutologout | 1.3.6.1.4.1.11.2.23.80.406 |
An administrator has been automatically disconnected from the HP Remote Assistant board. The administrator was inactive for more than five minutes. |
||
hpnsaRAAdministratorConnectionLost | 1.3.6.1.4.1.11.2.23.80.407 |
An administrator has been prematurely disconnected from the Remote Assistant board. |
||
hpnsaRAAdministratorDialbackFailed | 1.3.6.1.4.1.11.2.23.80.408 |
An administrator failed to connect to the HP Remote Assistant board on a dialback |
||
hpnsaRAASRHangNOS | 1.3.6.1.4.1.11.2.23.80.501 |
ASR has stopped notifying the HP Remote Assistant Card that the system is running correctly (the server probably hung or crashed). |
||
hpnsaRAASRServerRestart | 1.3.6.1.4.1.11.2.23.80.502 |
The HP Remote Assistant card has restarted the server due to the NOS being hung. |
||
hpnsaRAASRTimerEnabled | 1.3.6.1.4.1.11.2.23.80.503 |
The Automatic Server Restart software has been enabled by the Remote Assistant ASR timer. |
||
hpnsaRAASRTimerDisabled | 1.3.6.1.4.1.11.2.23.80.504 |
The HP Remote Assistant Automatic Server Restart timer has been disabled. |
||
hpnsaRARemoteInitiatedCtrlAltDel | 1.3.6.1.4.1.11.2.23.80.601 |
An administrator has executed a remote |
||
hpnsaRARemoteInitiatedReset | 1.3.6.1.4.1.11.2.23.80.602 |
An administrator has executed a remote power cycle on the server via the HP Remote Assistant Card. |
||
hpnsaRARemoteInitiatedPowerDown | 1.3.6.1.4.1.11.2.23.80.603 |
An administrator has executed a remote power down of the server via the HP Remote Assistant Card. |
||
hpnsaRAInitServerBIOS | 1.3.6.1.4.1.11.2.23.80.701 |
The server's BIOS has successfully initialized the HP Remote Assistant Card during the boot process. |
||
hpnsaRABusUtilization | 1.3.6.1.4.1.11.2.23.80.800 |
The 5-minute average EISA bus utilization has exceeded the configured threshold. |
||
hpnsaRATestNotification | 1.3.6.1.4.1.11.2.23.80.900 |
An administrator has executed Test Page from the HP Remote Assistant Configuration Utility. |
||
hpnsaRATAPNoConnect | 1.3.6.1.4.1.11.2.23.80.901 |
The HP Remote Assistant modem was unable to connect to the TAP paging service modem. |
||
hpnsaRATAPParam1Error | 1.3.6.1.4.1.11.2.23.80.902 |
HP Remote Assistant was unable to connect with the TAP paging service. |
||
hpnsaRATAPParam2Error | 1.3.6.1.4.1.11.2.23.80.903 |
HP Remote Assistant was unable to log on to the TAP paging service. |
||
hpnsaRATAPParam3Error | 1.3.6.1.4.1.11.2.23.80.904 |
The HP Remote Assistant pager message was rejected by the TAP paging service. |
||
hpnsaStorageCapWarning | 1.3.6.1.4.1.11.2.230.4096 |
Volume Storage Capacity has exceeded the warning threshold level. |
||
hpnsaStorageCapMinor | 1.3.6.1.4.1.11.2.230.4097 |
Volume Storage Capacity has exceeded the minor threshold level. |
||
hpnsaStorageCapMajor | 1.3.6.1.4.1.11.2.230.4098 |
Volume Storage Capacity has exceeded the major threshold level. |
||
hpnsaPostError | 1.3.6.1.4.1.11.2.230.4356 |
Post Error has occurred. |
||
hpnsaDiskSysDefects | 1.3.6.1.4.1.11.2.230.8210 |
The Defect List Threshold has been exceeded. |
||
hpnsaDaCacheError | 1.3.6.1.4.1.11.2.230.8609 |
HPDA Controller: Cache Error |
||
hpnsaDaLogicalDriveTrap | 1.3.6.1.4.1.11.2.230.8625 |
HPDA Logical Drive: Critical |
||
hpnsaDaLogicalDriveNotAvailable | 1.3.6.1.4.1.11.2.230.8626 |
HPDA Logical Drive Not Available |
||
hpnsaDaHotSpareFailure | 1.3.6.1.4.1.11.2.230.8641 |
HPDA Hot Spare:Failed |
||
hpnsaDaHotSpareSuccess | 1.3.6.1.4.1.11.2.230.8642 |
HPDA Hot Spare Succeeded |
||
hpnsaDaHardDiskFailure | 1.3.6.1.4.1.11.2.230.8657 |
HPDA Hard Disk Failed |
||
hpnsaDaParityThresholdTrap | 1.3.6.1.4.1.11.2.230.8673 |
HPDA Threshold Exceeded: Parity |
||
hpnsaDaSoftErrorThresholdTrap | 1.3.6.1.4.1.11.2.230.8674 |
HPDA Threshold Exceeded: Soft Errors |
||
hpnsaDaHardwareThresholdTrap | 1.3.6.1.4.1.11.2.230.8675 |
HPDA Threshold Exceeded: Hardware Errors |
||
hpnsaDaMiscThresholdTrap | 1.3.6.1.4.1.11.2.230.8676 |
HPDA Threshold Exceeded: Miscellaneous Errors |
||
hpnsaDaControllerTrap | 1.3.6.1.4.1.11.2.230.8677 |
HPDA Controller: NVRAM Age |
||
hpnsaRPSAbnormalCondition | 1.3.6.1.4.1.11.2.230.9101 |
The Redundant Power Supply module is not operating properly, but there is no power supply module hardware failure. |
||
hpnsaRPSACPowerSourceFailure | 1.3.6.1.4.1.11.2.230.9103 |
Indicates a failure with the AC power source that is connected to one of the redundant power supply units. |
||
hpnsaRPSPsuFailureDetected | 1.3.6.1.4.1.11.2.230.9105 |
Indicates that one of the redundant power supply modules is not in normal operating condition. |
||
hpnsaRPSDCShutdown | 1.3.6.1.4.1.11.2.230.9106 |
Indicates that one of the redundant power supply modules is in over temperature protection mode. |
||
hpnsaRPSPsuRemoved | 1.3.6.1.4.1.11.2.230.9107 |
Indicates that one of the redundant power supply modules has been physically removed from the HP NetServer Power Supply Subsystem. |
||
hpnsaRPSPsuInserted | 1.3.6.1.4.1.11.2.230.9108 |
Indicates that one of the redundant power supply modules has been physically inserted into the HP NetServer Power Supply Subsystem. |
||
hpnsaRPSPowerRestored | 1.3.6.1.4.1.11.2.230.9109 |
Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. |
||
hpnsaRPSWarningExceeded | 1.3.6.1.4.1.11.2.230.9110 |
Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. |
||
hpnsaRPSEmergencyExceeded | 1.3.6.1.4.1.11.2.230.9111 |
Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the emergency temperature level. |
||
hpnsaTempMonitorError | 1.3.6.1.4.1.11.2.230.12288 |
Server temperature monitor cannot read temperature data. |
||
hpnsaTempTrapWarning | 1.3.6.1.4.1.11.2.230.12289 |
Server temperature has exceeded the warning temperature threshold. |
||
hpnsaTempTrapEmergency | 1.3.6.1.4.1.11.2.230.12290 |
Server temperature has exceeded the emergency temperature threshold. |
||
hpnsaNicReceiveErrors | 1.3.6.1.4.1.11.2.230.16385 |
The total number of packets with receive errors has exceeded the threshold. |
||
hpnsaNicTransmitErrors | 1.3.6.1.4.1.11.2.230.16386 |
The total number of packets with transmit errors has exceeded the threshold. |
||
hpnsaNicAdapterReset | 1.3.6.1.4.1.11.2.230.16387 |
The total number of LAN Adapter reset errors has exceeded the threshold. |
||
hpnsaNicAlignmentErrors | 1.3.6.1.4.1.11.2.230.16388 |
The total number of alignment and CRC errors has exceeded the threshold. |
||
hpnsaNicGiantFrameErrors | 1.3.6.1.4.1.11.2.230.16389 |
The total number of giant frame packets has exceeded the threshold. |
||
hpnsaNicHardwareMismatch | 1.3.6.1.4.1.11.2.230.16390 |
The total number of packets with length less than the required minimum length has exceeded the threshold. |
||
hpnsaNicLateCollision | 1.3.6.1.4.1.11.2.230.16391 |
The total number of late collision errors has exceeded the threshold (the network is too large). |
||
hpnsaNicExcessiveCollision | 1.3.6.1.4.1.11.2.230.16392 |
The total number of colliding packets has exceeded the threshold (the network is too busy). |
||
hpnsaNicCarrierSenseError | 1.3.6.1.4.1.11.2.230.16393 |
The total number of carrier sense errors has exceeded the threshold. |
||
hpnsaNicDeferralError | 1.3.6.1.4.1.11.2.230.16394 |
The total number of adapter deferrals has exceeded the threshold (the network is forever busy). |
||
hpnsaNicNoECBError | 1.3.6.1.4.1.11.2.230.16395 |
The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. |
||
hpnsaNicReceiveOverflow | 1.3.6.1.4.1.11.2.230.16396 |
The total number of Receive Overflow errors has exceeded the threshold. |
||
hpnsaNicUtilCount | 1.3.6.1.4.1.11.2.230.16397 |
LAN adapter utilization count has exceeded the threshold. |
||
hpnsaNicAdapterMismatch | 1.3.6.1.4.1.11.2.230.16398 |
The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. |
||
hpnsaNicTxFIFOUnderrun | 1.3.6.1.4.1.11.2.230.16399 |
There possibly is a dataflow problem with your HP LAN adapter. |
||
hpnsaNicTxTimeOut | 1.3.6.1.4.1.11.2.230.16400 |
The HP LAN adapter driver did not receive a transmit complete interrupt. |
||
hpnsaNicRxFIFOOverrun | 1.3.6.1.4.1.11.2.230.16401 |
There possibly is a dataflow problem with your HP LAN adapter. |
||
hpnsaNicRxFalseInterrupts | 1.3.6.1.4.1.11.2.230.16402 |
There is a dataflow problem with your HP LAN adapter - receive interrupts are being generated, but no receive packets are being present. |
||
hpnsaNicPagingError | 1.3.6.1.4.1.11.2.230.16403 |
There possibly is a problem with your HP LAN adapter - it generates too many buffer pointer errors. |
||
hpnsaNicTimedOutDMA | 1.3.6.1.4.1.11.2.230.16404 |
There possibly is a problem with your HP LAN adapter - DMA timed out while transmitting or receiving a packet. |
||
hpnsaNicTxNoResources | 1.3.6.1.4.1.11.2.230.16405 |
The HP LAN adapter is transmitting faster than the media can handle. |
||
hpnsaNicTxExcessiveFrags | 1.3.6.1.4.1.11.2.230.16406 |
The number of buffer fragments has exceeded the maximum number allowed by the network protocol in your HP LAN adapter. |
||
hpnsaNicRxLow | 1.3.6.1.4.1.11.2.230.16407 |
The total number of errors due to requests of an ECB being denied has exceeded the threshold. |
||
hpnsaNicRxEmpty | 1.3.6.1.4.1.11.2.230.16408 |
There possibly is a problem with your HP LAN adapter running in bus master mode. |
||
hpnsaParityError | 1.3.6.1.4.1.11.2.230.20528 |
Parity error has been detected in parity memory |
||
hpnsaBusTimeoutError | 1.3.6.1.4.1.11.2.230.20544 |
One of the bus masters caused a bus timeout |
||
hpnsaIOChannelCheck | 1.3.6.1.4.1.11.2.230.20560 |
I/0 channel check activated by device in EISA slot caused an error |
||
hpnsaSoftwareNMI | 1.3.6.1.4.1.11.2.230.20576 |
Software NMI has been generated |
||
hpnsaPostMemoryResize | 1.3.6.1.4.1.11.2.230.20592 |
Memory size has been adjusted during the Power-On-Self-Test during the last boot |
||
hpnsaPciParityError | 1.3.6.1.4.1.11.2.230.20624 |
Parity error has occurred on a transfer to/from a device on one of the PCI buses |
||
hpnsaPciSystemError | 1.3.6.1.4.1.11.2.230.20640 |
System error has occurred in the PCI subsystem |
||
hpnsaCPUFailure | 1.3.6.1.4.1.11.2.230.20656 |
One or more CPUs have failed. Detected by BIOS during POST |
||
hpnsaFailsafeTimeout | 1.3.6.1.4.1.11.2.230.20672 |
Timeout of failsafe timer has occurred |
||
hpnsaErrorLoggingDisabled | 1.3.6.1.4.1.11.2.230.20704 |
Error logging for a specific error has been disabled due to too many errors of that kind in a short time period |
||
hpnsaSystemWarning | 1.3.6.1.4.1.11.2.230.20736 |
An event of warning severity has occurred in the system. For example, chassis door has been opened |
||
hpnsaSystemCritical | 1.3.6.1.4.1.11.2.230.20737 |
An event of critical severity has occurred in the system. For example, both system fans have failed |
||
hpnsaVoltEmergency | 1.3.6.1.4.1.11.2.230.20738 |
Fatal voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to CPU |
||
hpnsaVoltWarning | 1.3.6.1.4.1.11.2.230.20739 |
Warning voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to CPU |
||
hpnsaASRServerRestart | 1.3.6.1.4.1.11.2.230.20752 |
Server has been restarted after the system watchdog timer has timed out due to NOS being hung |
||
hpnsaSystemReconfig | 1.3.6.1.4.1.11.2.230.20800 |
EISA Configuration Utility has altered system configuration |
||
hpnsaHotSwapTempMonitorError | 1.3.6.1.4.1.11.2.230.24449 |
Hot Swap Cage: Temperature monitor error occurred |
||
hpnsaHotSwapTempWarning | 1.3.6.1.4.1.11.2.230.24451 |
Hot Swap Cage: Warning temperature exceeded |
||
hpnsaHotSwapTempEmergency | 1.3.6.1.4.1.11.2.230.24452 |
Hot Swap Cage: Emergency temperature exceeded! |
||
hpnsaHotSwapPowerFailure | 1.3.6.1.4.1.11.2.230.24453 |
Power connection failure in one of the devices in the hot swap cage |
||
hpnsaHotSwapDeviceRemoved | 1.3.6.1.4.1.11.2.230.24454 |
A device has been removed from the hot swap cage |
||
hpnsaHotSwapDeviceInserted | 1.3.6.1.4.1.11.2.230.24455 |
A device has been inserted into the hot swap cage |
||
hpnr | 1.3.6.1.4.1.16 | |||
hpNetRAID | 1.3.6.1.4.1.16.1 | |||
hpNetRaidMib | 1.3.6.1.4.1.16.1.1 | |||
raidTraps | 1.3.6.1.4.1.16.1.1.200 | |||
rtAdapterNumber | 1.3.6.1.4.1.16.1.1.200.1001 | integer | read-only |
Adapter Number for which Trap is generated. |
rtLogicalDriveNumber | 1.3.6.1.4.1.16.1.1.200.1002 | integer | read-only |
Logical Drive Number for which Trap is generated. |
rtChannelNumber | 1.3.6.1.4.1.16.1.1.200.1003 | integer | read-only |
Channel Number on the Adapter for which Trap is Generated. |
rtTargetID | 1.3.6.1.4.1.16.1.1.200.1004 | integer | read-only |
Device ID of the Physical Drive for which Trap is Generated. |
rtOldDriveState | 1.3.6.1.4.1.16.1.1.200.1005 | displaystring | read-only |
Old State of Logical/Physical Drive, when a State Change Trap is Generated. |
rtNewDriveState | 1.3.6.1.4.1.16.1.1.200.1006 | displaystring | read-only |
New State of Logical/Physical Drive, when a State Change Trap is Generated. |
rtSenseKey | 1.3.6.1.4.1.16.1.1.200.1007 | integer | read-only |
Check Condition Sense-Key reported by Physical Drive for which Trap is Generated. |
rtASC | 1.3.6.1.4.1.16.1.1.200.1008 | integer | read-only |
Check Condition Additional Sense Code (ASC) reported by Physical Drive for which Trap is Generated. |
rtASCQ | 1.3.6.1.4.1.16.1.1.200.1009 | integer | read-only |
Check Condition Additional Sense Code Qualifier (ASCQ) reported by Physical Drive for which Trap is Generated. |
rtDriveVendor | 1.3.6.1.4.1.16.1.1.200.1010 | displaystring | read-only |
Vendor Identification String from the SCSI Inquiry Data for the Drive. |
rtConfigUpdated | 1.3.6.1.4.1.16.1.1.2000.9001 |
Adapter-%d: A New Configuration has been written. |
||
rtPhysicalDriveStateChange | 1.3.6.1.4.1.16.1.1.2000.9002 |
Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. |
||
rtLogicalDriveStateChange | 1.3.6.1.4.1.16.1.1.2000.9003 |
Adapter-%d, Logical Drive-%d: State Changed from %s to %s. |
||
rtInitializeStarted | 1.3.6.1.4.1.16.1.1.2000.9004 |
Adapter-%d, Logical Drive-%d: Initialization Started. |
||
rtInitializeCompleted | 1.3.6.1.4.1.16.1.1.2000.9005 |
Adapter-%d, Logical Drive-%d: Initialization Completed Successfully. |
||
rtInitializeAborted | 1.3.6.1.4.1.16.1.1.2000.9006 |
Adapter-%d, Logical Drive-%d: Initialization Aborted by User. |
||
rtInitializeFailed | 1.3.6.1.4.1.16.1.1.2000.9007 |
Adapter-%d, Logical Drive-%d: Initialization Failed. |
||
rtCheckConsistencyStarted | 1.3.6.1.4.1.16.1.1.2000.9008 |
Adapter-%d, Logical Drive-%d: Check Consistency Started. |
||
rtCheckConsistencyCompleted | 1.3.6.1.4.1.16.1.1.2000.9009 |
Adapter-%d, Logical Drive-%d: Check Consistency Completed. No Inconsistencies Found. |
||
rtCheckConsistencyAborted | 1.3.6.1.4.1.16.1.1.2000.9010 |
Adapter-%d, Logical Drive-%d: Check Consistency Aborted by User. |
||
rtConsistencyCorrected | 1.3.6.1.4.1.16.1.1.2000.9011 |
Adapter-%d, Logical Drive-%d: Check Consistency Operation Completed. Inconsistencies have been Cured. |
||
rtCheckConsistencyFailed | 1.3.6.1.4.1.16.1.1.2000.9012 |
Adapter-%d, Logical Drive-%d: Check Consistency Failed. |
||
rtReconstructionStarted | 1.3.6.1.4.1.16.1.1.2000.9013 |
Adapter-%d, Logical Drive-%d: Reconstruction Started. |
||
rtReconstructionCompleted | 1.3.6.1.4.1.16.1.1.2000.9014 |
Adapter-%d, Logical Drive-%d: Reconstruction Completed Successfully. |
||
rtReconstructionFailed | 1.3.6.1.4.1.16.1.1.2000.9015 |
Adapter-%d, Logical Drive-%d: Reconstruction Failed. |
||
rtPredictiveFailuresFalse | 1.3.6.1.4.1.16.1.1.2000.9016 |
Adapter-%d, Channel-%d, Target-%d: Reported Failure Prediction Threshold Exceeded [FALSE]. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. |
||
rtPredictiveFailuresExceeded | 1.3.6.1.4.1.16.1.1.2000.9017 |
Adapter-%d, Channel-%d, Target-%d: Reported Predictive Failure. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. |
||
rtCheckConditionStatus | 1.3.6.1.4.1.16.1.1.2000.9018 |
Adapter-%d, Channel-%d, Target-%d: Command Completed with Sense_Key-0x%x ASC-0x%x ASCQ-0x%x. |
||
rtNewDriveInserted | 1.3.6.1.4.1.16.1.1.2000.9019 |
Adapter-%d, Channel-%d, Target-%d: New Device Inserted. |
||
rtBatteryMissing | 1.3.6.1.4.1.16.1.1.2000.9020 |
Adapter-%d: Battery Module is missing. |
||
rtBatteryVolatageLow | 1.3.6.1.4.1.16.1.1.2000.9021 |
Adapter-%d: Battery Module Voltage is Low. |
||
rtBatteryTemperatureHigh | 1.3.6.1.4.1.16.1.1.2000.9022 |
Adapter-%d: Battery Module Temperature Exceeded Danger Threshold. |
||
adaptec | 1.3.6.1.4.1.795 | |||
storagemanagement | 1.3.6.1.4.1.795.2 | |||
cyclone | 1.3.6.1.4.1.795.2.5 | |||
cycTraps | 1.3.6.1.4.1.795.2.5.9000 | |||
cycManagerID | 1.3.6.1.4.1.795.2.5.9000.9001 | displaystring | read-only |
ASCII String description of SCSI Manager |
cycHostAdapterID | 1.3.6.1.4.1.795.2.5.9000.9002 | displaystring | read-only |
ASCII String description of Hostadapter |
cycHostAdapterNumber | 1.3.6.1.4.1.795.2.5.9000.9003 | integer | read-only |
The unique Hostadapter Number |
cycVendor | 1.3.6.1.4.1.795.2.5.9000.9004 | displaystring | read-only |
This indicates the Name of the Vendor |
cycProduct | 1.3.6.1.4.1.795.2.5.9000.9005 | displaystring | read-only |
This indicates the product information |
cycControllerModel | 1.3.6.1.4.1.795.2.5.9000.9006 | displaystring | read-only |
The model of the associated controller e.g ATHENA, VIKING etc |
cycBusNumber | 1.3.6.1.4.1.795.2.5.9000.9007 | integer | read-only |
The PCI Bus number |
cycChannelNumber | 1.3.6.1.4.1.795.2.5.9000.9008 | integer | read-only |
Channel Number |
cycScsiTargetID | 1.3.6.1.4.1.795.2.5.9000.9009 | integer | read-only |
SCSI Target ID |
cycLun | 1.3.6.1.4.1.795.2.5.9000.9010 | integer | read-only |
The LUN of the device ID |
cycArrayName | 1.3.6.1.4.1.795.2.5.9000.9011 | displaystring | read-only |
Array name |
cycMisCompares | 1.3.6.1.4.1.795.2.5.9000.9012 | integer | read-only |
The number of miscompares in verify |
cycDriver | 1.3.6.1.4.1.795.2.5.9000.9013 | integer | read-only |
The Driver version |
cycManager | 1.3.6.1.4.1.795.2.5.9000.9014 | integer | read-only |
The CI/O Manager version |
cycOldArrayName | 1.3.6.1.4.1.795.2.5.9000.9015 | displaystring | read-only |
Old Array name |
cycNewArrayName | 1.3.6.1.4.1.795.2.5.9000.9016 | displaystring | read-only |
Changed Array name |
cycPriority | 1.3.6.1.4.1.795.2.5.9000.9017 | integer | read-only |
The Priority of the operation |
cycSenseInfo | 1.3.6.1.4.1.795.2.5.9000.9018 | integer | read-only |
The sense info of the PFA |
cycSNMPAgentIsUp | 1.3.6.1.4.1.795.2.50.101 |
SNMP Agent is up. |
||
cycSNMPAgentIsDown | 1.3.6.1.4.1.795.2.50.102 |
SNMP Agent is down. |
||
cycDuplicateHostAdapter | 1.3.6.1.4.1.795.2.50.107 |
Cyclone: duplicate hostadapter ID |
||
cycHostAdapterDiscovered | 1.3.6.1.4.1.795.2.50.108 |
The HostAdapter# %d with HostAdapter Id %s and Manager Id %s is discovered |
||
cycHostAdapterChanged | 1.3.6.1.4.1.795.2.50.109 |
The HostAdapter# %d has new HostAdapter Id %s and Manager Id %s |
||
cycHostAdapterFailed | 1.3.6.1.4.1.795.2.50.110 |
The HostAdapter# %d has Failed |
||
cycHostAdapterRecovered | 1.3.6.1.4.1.795.2.50.111 |
Host Adapter# %d recovered |
||
cycDeviceFailed | 1.3.6.1.4.1.795.2.50.112 |
The HostAdapter# %d , TargetID %d, Lun# %d has failed |
||
cycDeviceDiscovered | 1.3.6.1.4.1.795.2.50.113 |
The HostAdapter# %d , TargetID %d, Lun# %d of vendor %s product %s has discovered |
||
cycDeviceRecovered | 1.3.6.1.4.1.795.2.50.114 |
The HostAdapter# %d , TargetID %d, Lun# %d has recovered |
||
cycDeviceChanged | 1.3.6.1.4.1.795.2.50.115 |
The HostAdapter# %d , TargetID %d, Lun# %d has new Vendor %s and Product %s information |
||
cycPredictiveFailure | 1.3.6.1.4.1.795.2.50.116 |
The HostAdapter# %d , TargetID %d, Lun# %d has Predictive Failure Condition on vendor %s product %s with sense info MSB(sense code), next 8 bits(sense code Qual) next 8 bits (Add sense code Qual) LSB (0000) %d |
||
cycAspiDatabaseCleared | 1.3.6.1.4.1.795.2.50.117 |
The Aspi database is cleared and therefore all the previous information are not available |
||
cycAspiCrash | 1.3.6.1.4.1.795.2.50.118 |
The Aspi has crashed |
||
cycAspiNoMemory | 1.3.6.1.4.1.795.2.50.119 |
No memory left for Aspi Operations |
||
cycAspiFileWriteOpenError | 1.3.6.1.4.1.795.2.50.120 |
Unable to open Aspi file for writing, problem exists in server hard disk |
||
cycAspiFileWriteError | 1.3.6.1.4.1.795.2.50.121 |
Unable to open Aspi file , problem exists in server hard disk |
||
cycAspiNoDeviceFile | 1.3.6.1.4.1.795.2.50.122 |
Aspi device file doesnot exist |
||
cycAspiNoMemoryReading | 1.3.6.1.4.1.795.2.50.123 |
Aspi: Memory allocation is failing |
||
cycAspiFileReadError | 1.3.6.1.4.1.795.2.50.124 |
Aspi: unable to read the file server hard disk might have problems |
||
cycAspiBadFileMagic | 1.3.6.1.4.1.795.2.50.125 |
Aspi: database is corrupted |
||
adaptecNm | 1.3.6.1.4.1.795.4 | |||
adaptecNmScsiStatus | 1.3.6.1.4.1.795.4.1 | |||
hpnsaScsiStatusCorruptedDB | 1.3.6.1.4.1.795.4.10.8193 |
Device Database has been corrupted. |
||
hpnsaScsiStatusUnloadedNLM | 1.3.6.1.4.1.795.4.10.8194 |
SCSI Status agent was unloaded from a NetWare Server. |
||
hpnsaScsiStatusFailedHBA | 1.3.6.1.4.1.795.4.10.8196 |
One of the SCSI HBAs can no longer be detected by the SCSI Status agent. |
||
hpnsaScsiStatusRecoveredHBA | 1.3.6.1.4.1.795.4.10.8197 |
A Host Adapter which has failed, has become accessible again. |
||
hpnsaScsiStatusDiscoveredHBA | 1.3.6.1.4.1.795.4.10.8198 |
A new SCSI Host Bus Adapter has been discovered or device database has been cleared. |
||
hpnsaScsiStatusDeviceFailed | 1.3.6.1.4.1.795.4.10.8199 |
One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. |
||
hpnsaScsiStatusDeviceRecovered | 1.3.6.1.4.1.795.4.10.8200 |
A SCSI device which has failed, has become accessible again. |
||
hpnsaScsiStatusDeviceDiscovered | 1.3.6.1.4.1.795.4.10.8201 |
A new SCSI device has been discovered. |
||
hpnsaScsiStatusChangedHBA | 1.3.6.1.4.1.795.4.10.8205 |
The SCSI Status agent detected that the Host Bus Adapter has been changed. |
||
hpnsaScsiStatusDeviceChanged | 1.3.6.1.4.1.795.4.10.8206 |
The SCSI Status agent detected that a SCSI device installed on the server has been changed. |
||
hpnsaScsiStatusTimeoutHBA | 1.3.6.1.4.1.795.4.10.8208 |
The SCSI Status agent sent a request to an HBA and the request never completed. |
||
hpnsaScsiStatusDeviceTimeout | 1.3.6.1.4.1.795.4.10.8209 |
The SCSI Status agent sent a request to a SCSI device and the request never completed. |