Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hp 1.3.6.1.4.1.11
       nm 1.3.6.1.4.1.11.2
           hpnsa 1.3.6.1.4.1.11.2.23
                 hpIpfE0Events 1.3.6.1.4.1.11.2.23.35
                 hpIpf02Events 1.3.6.1.4.1.11.2.23.45
                       hpIpfEvtDetailStr 1.3.6.1.4.1.11.2.23.45.1 displaystring read-only
This string provides a detailed description of the Event along with variable information.
                         hpTemperature4 1.3.6.1.4.1.11.2.23.450.4
One of the temperature sensors crossed its upper non-critical threshold.
                         hpTemperature5 1.3.6.1.4.1.11.2.23.450.5
One of the temperature sensors crossed its upper critical threshold.
                         hpTemperature6 1.3.6.1.4.1.11.2.23.450.6
One of the temperature sensors crossed its upper non-recoverable threshold.
                         hpEnvironment8 1.3.6.1.4.1.11.2.23.450.8
One of the voltage sensors crossed its lower critical threshold.
                         hpEnvironment9 1.3.6.1.4.1.11.2.23.450.9
One of the voltage sensors crossed its lower non-recoverable threshold.
                         hpEnvironment10 1.3.6.1.4.1.11.2.23.450.10
One of the voltage sensors crossed its upper non-critical threshold.
                         hpEnvironment12 1.3.6.1.4.1.11.2.23.450.12
One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
                         hpChassis26 1.3.6.1.4.1.11.2.23.450.26
The chassis has been opened.
                         hpSystemHW113 1.3.6.1.4.1.11.2.23.450.113
A SCSI cable has been removed from the hot swap cage.
                         hpECCMemory518 1.3.6.1.4.1.11.2.23.450.518
Uncorrectable multi-bit ECC error has occurred in memory module
                         hpSystemFW699 1.3.6.1.4.1.11.2.23.450.699
Machine Check Initiated
                         hpSystemFW700 1.3.6.1.4.1.11.2.23.450.700
System firmware error
                         hpEnvironment704 1.3.6.1.4.1.11.2.23.450.704
Voltage fault - Check all boards with this voltage
                         hpEnvironment705 1.3.6.1.4.1.11.2.23.450.705
Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
                         hpEnvironment706 1.3.6.1.4.1.11.2.23.450.706
Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
                         hpEnvironment707 1.3.6.1.4.1.11.2.23.450.707
Voltage absent
                         hpFan710 1.3.6.1.4.1.11.2.23.450.710
Fan speed lags
                         hpRedundantPower720 1.3.6.1.4.1.11.2.23.450.720
Power supply failed or disconnected
                         hpRedundantPower722 1.3.6.1.4.1.11.2.23.450.722
Power supply AC lost
                         hpPowerSupply726 1.3.6.1.4.1.11.2.23.450.726
A/C Failed, disconnected, or out of range
                         hpEnvironment728 1.3.6.1.4.1.11.2.23.450.728
Voltage degraded to critical level from less severe - Check all boards with this voltage
                         hpSystemHW729 1.3.6.1.4.1.11.2.23.450.729
System shut-down or reset caused by sensor reading.
                         hpBmcFirmware730 1.3.6.1.4.1.11.2.23.450.730
The BMC firmware did not detect the system firmware boot.
                         hpPowerSupply731 1.3.6.1.4.1.11.2.23.450.731
A/C Failed, disconnected, or out of range
                         hpRedundantPower732 1.3.6.1.4.1.11.2.23.450.732
The Power supply's sensors detect possible problems
                         hpSystemHW733 1.3.6.1.4.1.11.2.23.450.733
Cooling unit warning
                         hpSystemHW734 1.3.6.1.4.1.11.2.23.450.734
Cooling unit failure
                         hpSystemHW735 1.3.6.1.4.1.11.2.23.450.735
BMC entering special mode
                         hpSystemHW736 1.3.6.1.4.1.11.2.23.450.736
Watchdog timer expired - hard reset
                         hpSystemHW737 1.3.6.1.4.1.11.2.23.450.737
Watchdog timer expired - power-off
                         hpSystemHW738 1.3.6.1.4.1.11.2.23.450.738
Watchdog timer expired - power-cycle
                         hpSystemHW739 1.3.6.1.4.1.11.2.23.450.739
Missing FRU device
                         hpSystemHW740 1.3.6.1.4.1.11.2.23.450.740
Missing Entity
                         hpSystemHW744 1.3.6.1.4.1.11.2.23.450.744
System event log almost full
                         hpSystemHW745 1.3.6.1.4.1.11.2.23.450.745
TOC interrupt (crash dump)
                         hpSystemHW746 1.3.6.1.4.1.11.2.23.450.746
INIT Initiated
                         hpSystemHW747 1.3.6.1.4.1.11.2.23.450.747
PCI system error detected
                         hpSystemHW748 1.3.6.1.4.1.11.2.23.450.748
OS run-time critical shutdown
                         hpSystemHW749 1.3.6.1.4.1.11.2.23.450.749
ACPI state S5 (soft-off, entered by override)
                         hpSystemHW751 1.3.6.1.4.1.11.2.23.450.751
PCI parity error detected
                         hpTempHighWarning752 1.3.6.1.4.1.11.2.23.450.752
One of the temperature sensors crossed its lower non-critical threshold.
                         hpTempHighCritical753 1.3.6.1.4.1.11.2.23.450.753
One of the temperature sensors crossed its upper critical threshold.
                         hpTempHighNonRecoverable754 1.3.6.1.4.1.11.2.23.450.754
One of the temperature sensors crossed its upper non-recoverable threshold.
                         hpTemperature755 1.3.6.1.4.1.11.2.23.450.755
A temperature inside the server has gone outside the factory specified range.
                         hpTemperature756 1.3.6.1.4.1.11.2.23.450.756
One of the temperature sensors crossed its upper critical threshold.
                         hpRedundantPower757 1.3.6.1.4.1.11.2.23.450.757
The Power Supply AC voltage was lost or is out of range.
                         hpRedundantPower758 1.3.6.1.4.1.11.2.23.450.758
The AC voltage connected to the power supply is out of range.