HM2-PWRMGMT-MIB: View SNMP OID List / Download MIB

VENDOR: RICHARD HIRSCHMANN


 Home MIB: HM2-PWRMGMT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hm2PowerMgmtMib 1.3.6.1.4.1.248.11.11
Hirschmann Power Management MIB. Copyright (C) 2011. All Rights Reserved.
       hm2PowerMgmtMibNotifications 1.3.6.1.4.1.248.11.11.0
           hm2PowerSupplyTrap 1.3.6.1.4.1.248.11.11.0.1
This trap is sent when the value of hm2PSState has been changed.
       hm2PowerMgmtMibObjects 1.3.6.1.4.1.248.11.11.1
           hm2PowerSupplyGroup 1.3.6.1.4.1.248.11.11.1.1
               hm2PSTable 1.3.6.1.4.1.248.11.11.1.1.1 no-access
This table contains all variables related to the power supply units of the chassis/switch. For each power supply slot exists one instance.
                   hm2PSEntry 1.3.6.1.4.1.248.11.11.1.1.1.1 no-access
The entry of the hm2PSTable.
                       hm2PSID 1.3.6.1.4.1.248.11.11.1.1.1.1.1 integer32 read-only
This index is used to identify the associated power supply unit.
                       hm2PSState 1.3.6.1.4.1.248.11.11.1.1.1.1.2 integer read-only
Indicates the operational state of the associated power supply. If the value of this variable changes, a hm2PowerSupply trap is sent. Enumeration: 'unknown': 4, 'notInstalled': 3, 'defective': 2, 'present': 1.
               hm2PSUSlotInfoTable 1.3.6.1.4.1.248.11.11.1.1.10 no-access
This table contains all EEPROM variables related to the power supply slot modules of the chassis/switch. For each power supply slot module exists one instance.
                     hm2PSUSlotInfoEntry 1.3.6.1.4.1.248.11.11.1.1.10.1 no-access
The entry of the hm2PSUSlotInfoTable.
                         hm2PSUSlotIndex 1.3.6.1.4.1.248.11.11.1.1.10.1.1 integer32 no-access
This index is used to identify the associated power supply slot module.
                         hm2PSUSlotChassisTypeId 1.3.6.1.4.1.248.11.11.1.1.10.1.2 integer read-only
The chassis type id of the associated power supply slot module. Enumeration: 'grs': 4, 'other': 0, 'railswitch': 3, 'mach1020': 1, 'mach4000': 2.
                         hm2PSUSlotManufacturerId 1.3.6.1.4.1.248.11.11.1.1.10.1.3 integer read-only
The manufacturer id of the associated power supply slot module. Enumeration: 'hirschmann': 1, 'other': 0.
                         hm2PSUSlotManufacturerDate 1.3.6.1.4.1.248.11.11.1.1.10.1.4 snmpadminstring read-only
The manufacturer date of the associated power supply slot module. *** NOTE this is set to OBSOLETE ***
                         hm2PSUSlotSerialNumber 1.3.6.1.4.1.248.11.11.1.1.10.1.5 snmpadminstring read-only
The serial number of the associated power supply slot module.
                         hm2PSUSlotProductCode 1.3.6.1.4.1.248.11.11.1.1.10.1.6 snmpadminstring read-only
The product code of the associated power supply slot module.
                         hm2PSUSlotDescription 1.3.6.1.4.1.248.11.11.1.1.10.1.7 snmpadminstring read-only
The description of the associated power supply slot module.
                         hm2PSUSlotCombinationType 1.3.6.1.4.1.248.11.11.1.1.10.1.8 integer read-only
The combination type of the associated power supply slot module. Enumeration: 'only-on-psu1': 0, 'psu1-poe-psu2-sys': 2, 'psu1-sys-psu2-poe': 1, 'two-separate-psus': 3.
                         hm2PSUSlotTemperatureRange 1.3.6.1.4.1.248.11.11.1.1.10.1.9 integer read-only
The temperature range of the associated power supply slot module. Enumeration: 'tr-0-60': 0, 'tr-minus40-60': 1, 'tr-minus40-70': 2, 'tr-minus40-85': 4, 'tr-minus40-85cc': 5, 'tr-minus40-70cc': 3.
                         hm2PSUSlotRevisionId 1.3.6.1.4.1.248.11.11.1.1.10.1.10 integer32 read-only
Hardware revision of the PSU
               hm2PSUUnitInfoTable 1.3.6.1.4.1.248.11.11.1.1.20 no-access
This table contains all EEPROM variables related to the power supply slot module units. For each power supply slot module exists up to two instances.
                     hm2PSUUnitInfoEntry 1.3.6.1.4.1.248.11.11.1.1.20.1 no-access
The entry of the hm2PSUUnitInfoTable.
                         hm2PSUUnitIndex 1.3.6.1.4.1.248.11.11.1.1.20.1.1 integer32 no-access
The number of PSU units on the associated power supply slot module.
                         hm2PSUUnitConverterType 1.3.6.1.4.1.248.11.11.1.1.20.1.2 integer read-only
The converter type of the associated power supply slot module unit. Enumeration: 'ac': 1, 'dc': 2.
                         hm2PSUUnitNumberOfInputs 1.3.6.1.4.1.248.11.11.1.1.20.1.3 integer32 read-only
The number of inputs of the associated power supply slot module unit.
                         hm2PSUUnitOutputType 1.3.6.1.4.1.248.11.11.1.1.20.1.4 integer read-only
The output type of the associated power supply slot module unit. Enumeration: 'both': 2, 'poe': 3, 'system': 1.
                         hm2PSUUnitSystemBudget 1.3.6.1.4.1.248.11.11.1.1.20.1.5 integer32 read-only
The system budget of the associated power supply slot module unit.
                         hm2PSUUnitPoeBudget 1.3.6.1.4.1.248.11.11.1.1.20.1.6 integer32 read-only
The Poe budget of the associated power supply slot module unit.
                         hm2PSUUnitFanCount 1.3.6.1.4.1.248.11.11.1.1.20.1.7 integer32 read-only
The fan count of the associated power supply slot module unit.
                         hm2PSUUnitVoltageRange 1.3.6.1.4.1.248.11.11.1.1.20.1.8 integer read-only
The voltage range of the associated power supply slot module unit. Enumeration: 'vr-24-60vdc': 1, 'vr-24-48vdc': 2, 'vr-60-250vdc-110-240vac': 3, 'vr-18-60vdc': 0, 'vr-48-54vdc-poe': 4.
                         hm2PSUUnitPowerInterruption 1.3.6.1.4.1.248.11.11.1.1.20.1.9 integer read-only
The power interruption value of the associated power supply slot module unit. Enumeration: 'yes': 1, 'no': 2.