H320TERMINAL-MIB: View SNMP OID List / Download MIB

VENDOR: INTERNET-STANDARD


 Home MIB: H320TERMINAL-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 h320TerminalMIB 1.3.6.1.3.320.3
This MIB module supports the functions of an ITU H.320 terminal
     system 1.3.6.1.3.320.3.1
         sysDescr 1.3.6.1.3.320.3.1.1 displaystring read-only
A textual description of the terminal. This value should include the full name and version identification of the system's hardware type and software.
         sysContact 1.3.6.1.3.320.3.1.2 displaystring read-only
The textual identification of the contact person for this managed node, together with information on how to contact this person.
         syst35CountryCode 1.3.6.1.3.320.3.1.3 integer read-only
Country code, per T.35.
         syst35CountryCodeExtention 1.3.6.1.3.320.3.1.4 integer read-only
Assigned nationally.
         syst35ManufacturerCode 1.3.6.1.3.320.3.1.5 integer read-only
Assigned nationally.
         sysLocation 1.3.6.1.3.320.3.1.6 displaystring read-only
The physical location of this system. For instance, closet, terminal room and so on
         sysH320TerminalUptime 1.3.6.1.3.320.3.1.7 timeticks read-only
The amount of time (in hundredths of a second) since this H320 terminal was last initialized. Note that this is different from sysUpTime in MIB-II [ ] because sysUpTime is the uptime of the network management portion of the system.
         sysH320TerminalLocalTime 1.3.6.1.3.320.3.1.8 dateandtime read-write
The local date and time of day.
         sysH320TerminalDiagnostics 1.3.6.1.3.320.3.1.9 integer read-only
Indicates the results of the last diagnostic routine performed. noResults(1) No diagnostic has yet been performed, passed(2) the diagnostic has been passed, hardwareFault(3) Hardware fault was detected, softwareFault(4) Software fault was detected. Enumeration: 'softwareFault': 4, 'hardwareFault': 3, 'noResults': 1, 'passed': 2.
         sysH320TerminalStatus 1.3.6.1.3.320.3.1.10 integer read-only
General status of the terminal Enumeration: 'idle': 4, 'callinProgress': 2, 'callSetup': 1, 'callHangUp': 3.
         sysH320TerminalIfType 1.3.6.1.3.320.3.1.11 integer32 read-only
The interface type on which this terminal can be called. The interface type identified by this value is the same type of as the ifType from Interface Table in RFC1213. It should only use ifTypes - ds1, e1, basicISDN, primaryISDN.
     configuration 1.3.6.1.3.320.3.2
         configH320TerminalSiteName 1.3.6.1.3.320.3.2.1 displaystring read-write
Name of the site where the H320 terminal is located. For instance, conference room 1 in Austin, or New York, and so on. sysLocation provides the location information for the maintenance people and this object inform where the conference participants are.
         configH320TerminalVideoSystem 1.3.6.1.3.320.3.2.2 integer read-write
Video format standard used by the terminal Enumeration: 'pal': 2, 'secam': 3, 'ntsc': 1, 'others': 4.
         configH320TerminalIPAddress 1.3.6.1.3.320.3.2.3 ipaddress read-write
The IP address of the h.320 terminal.
         configH320ISDNSwitchType 1.3.6.1.3.320.3.2.4 isdnsignalingprotocol read-write
Type of ISDN switch interface to the h.320 terminal. Switch types are specified in ISDN-MIB.
         configH320ISDNAddrNumber 1.3.6.1.3.320.3.2.5 integer32 read-write
The number of addresses that each terminal has.
         configISDNAddrTable 1.3.6.1.3.320.3.2.6 no-access
AN ISDN address table.
             configISDNAddrEntry 1.3.6.1.3.320.3.2.6.1 no-access
AN ISDN address row.
                 configH320AddrIndex 1.3.6.1.3.320.3.2.6.1.1 integer no-access
A unique value for each ISDN address entry. the value ranges between 1 and the value of cionfigISDNAddrNumber.
                 configH320ISDNAddress 1.3.6.1.3.320.3.2.6.1.2 displaystring read-write
ISDN port address.
                 configH320ISDNSPID 1.3.6.1.3.320.3.2.6.1.3 displaystring read-write
ISDN port SPID.
     callSites 1.3.6.1.3.320.3.3
         h320CallSiteNumber 1.3.6.1.3.320.3.3.1 integer32 read-write
The number of site entries that this system contains.
         h320XferNextIndex 1.3.6.1.3.320.3.3.2 integer read-only
Identifies the next value of h320SiteIndex to be used in a row creation attempt for the h320CallSiteTable. If new rows cannot be created, this object will have a value of 0.
         h320CallSiteTable 1.3.6.1.3.320.3.3.3 no-access
A list of video conferencing site entries. The total number of site entries is given by the value of h320CallsiteNumber.
             h320CallSiteEntry 1.3.6.1.3.320.3.3.3.1 no-access
A video conference site row. Rows are created by an SNMP SET request setting the value of h320SiteRowStatus to 'createandGo. Rows are deleted by an SNMP SET request setting the value of h320SiteRowStatus to 'destroy'.
                 h320SiteIndex 1.3.6.1.3.320.3.3.3.1.1 integer no-access
A unique value for each video conference Site entry. The value ranges between 1 and the value of h320SiteNumber.
                 h320SiteName 1.3.6.1.3.320.3.3.3.1.2 displaystring read-only
A textual string assigning a name to a video conference system.
                 h320SiteIfType 1.3.6.1.3.320.3.3.3.1.3 integer32 read-only
The interface type on which this site can be called. The interface type identified by this value is the same type of as the ifType from Interface Table in RFC1213. It should onlye use ifTypes - ds1, e1, basicISDN, primaryISDN.
                 h320SiteLineRate 1.3.6.1.3.320.3.3.3.1.4 linerates read-only
The line rate that the terminal can be called.
                 h320CallMode 1.3.6.1.3.320.3.3.3.1.5 integer read-only
1 means the remote terminal supports the autoconfiguration. 2 means the manual configuration is required to call the remote terminal. In this case the, following audio, video and data mode shall be used for the manual configuration. Enumeration: 'manualConfig': 1, 'autoConfig': 2.
                 h320VideoMode 1.3.6.1.3.320.3.3.3.1.6 videoformats read-only
A video mode for manual configuration.
                 h320AudioMode 1.3.6.1.3.320.3.3.3.1.7 audiotypes read-only
An audio mode for manual configuration.
                 h320ISDNAddrNumber 1.3.6.1.3.320.3.3.3.1.8 integer32 read-only
The number of ISDN addresses needed to make a call to the remote terminal.
                 h320SiteRowStatus 1.3.6.1.3.320.3.3.3.1.9 rowstatus read-only
The row status of the entry. This object is required to create or delete rows administratively. An agent implementing this object is not required to support the values 'createAndWait' and 'notInService'.
         h320ISDNAddrTable 1.3.6.1.3.320.3.3.4 no-access
A list of ISDN addresses to call the remote site. This is an extended table of the base table h320CallSiteTable.
             h320ISDNAddrEntry 1.3.6.1.3.320.3.3.4.1 no-access
A video conference site row. Rows are created by an SNMP SET request setting the value of h320AddrRowStatus to 'createandGo. Rows are deleted by an SNMP SET request setting the value of h320AddrRowStatus to 'destroy'
                 h320AddrIndex 1.3.6.1.3.320.3.3.4.1.1 unsigned32 no-access
A unique value for each ISDN address entry. The value ranges between 1 and the value of h320AddrNumberin the base table.
                 h320ISDNAddress 1.3.6.1.3.320.3.3.4.1.2 displaystring read-only
A textual string assigning an address of the conference system.
                 h320AddrRowStatus 1.3.6.1.3.320.3.3.4.1.3 rowstatus read-only
The row status of the entry. This object is required to create or delete rows administratively. An agent implementing this object is not required to support the values 'createAndWait' and 'notInService'.
     control 1.3.6.1.3.320.3.4
         controlH320TerminalAdmin 1.3.6.1.3.320.3.4.1 integer read-write
The desired state of the H320 terminal. Setting the value if this object to these values will have the following actions: run(1) The H320 terminal will enter the run state, reset(2) The H320 terminal will reset, diagnose(3) Will activate the diagnostic routine, stop(4) Will halt the H320 terminal. Enumeration: 'reset': 2, 'diagnose': 3, 'stop': 4, 'run': 1.
         controlH320TerminalCallSetUp 1.3.6.1.3.320.3.4.2 integer32 read-write
Dial another video conference terminal. Set this value to the index of the site of the video conference site you want to dial in the Site Table in the h320CallSignalingMIB and the system will be dialed.
         controlH320TerminalCallHangup 1.3.6.1.3.320.3.4.3 integer32 read-write
Hang up the video conference call in progress now.
         controlH320EnableLocalLoopback 1.3.6.1.3.320.3.4.4 integer read-write
Enable or disable local loop back on a video conference system. Local loopbacks loop back the audio, video and data streams in a call. Once looped back, a new call will show up and the user can observe the audio/video/data rates to assure that these components are working properly. Enumeration: 'enable': 1, 'disable': 2.
         controlH320EnableRemoteLoopback 1.3.6.1.3.320.3.4.5 integer read-write
Enable or disable remote loop back on a video conference system. Remote loopbacks loop back the audio and video streams from the remote system in a call.. When the remote system calls in, a new call will show and the user can observe the audio/video/data rates to assure that these components are coming in properly from the remote system. Enumeration: 'enable': 1, 'disable': 2.
     h320TerminalMIBConfs 1.3.6.1.3.320.3.5
         h320TerminalMIIBGroups 1.3.6.1.3.320.3.5.1
             h320TerminalDesrGroup 1.3.6.1.3.320.3.5.1.1
A collection of objects providing the description of the terminal
             h320TerminalConfgGroup 1.3.6.1.3.320.3.5.1.2
A collection of objects providing the ability to configure the terminal
             h320TerminalCallSitesGroup 1.3.6.1.3.320.3.5.1.3
A collection of objects providing the information about the site the terminal can call
             h320TerminalControlGroup 1.3.6.1.3.320.3.5.1.4
A collection of objects providing the ability to invoke terminal functions
         h320TerminalMIBCompl 1.3.6.1.3.320.3.5.2
             h320TErminalCompliance 1.3.6.1.3.320.3.5.2.1
The set of objects required for compliance