Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 codex 1.3.6.1.4.1.449
         cdxProductSpecific 1.3.6.1.4.1.449.2
             cdx6500 1.3.6.1.4.1.449.2.1
                 cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
                     cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
                         cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
                             cdx6500PPCTGSCPortTable 1.3.6.1.4.1.449.2.1.2.1.1.29 no-access
This table contains GSC port configuration parameters.
                                   cdx6500PPCTGSCPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.29.1 no-access
Configuration parameters relevant to a GSC port.
                                       cdx6500GSCPCfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.29.1.1 integer read-only
Port number of the port being used by GSC
                                       cdx6500GSCPCfgPortType 1.3.6.1.4.1.449.2.1.2.1.1.29.1.2 integer read-only
The Port Type of the port. Enumeration: 'gsc': 51.
                                       cdx6500GSCPCfgSubtype 1.3.6.1.4.1.449.2.1.2.1.1.29.1.3 integer read-only
The GSC port sub-type. gscHpad - Port is functioning as a host PAD. gscTpad - Port is functioning as a terminal PAD. Enumeration: 'gscTpad': 1, 'gscHpad': 2.
                                       cdx6500GSCPCfgClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.29.1.4 integer read-only
This is the clock speed of the port in bits per second, when internal clocking is used. Enumeration: 'speed4800': 14, 'speed19200': 16, 'speed9600': 15, 'nc': 100, 'speed1800': 8, 'speed1200': 4, 'speed2400': 13.
                                       cdx6500GSCPCfgNumStations 1.3.6.1.4.1.449.2.1.2.1.1.29.1.5 integer read-only
The number of stations/devices configured on this port.
                                       cdx6500GSCPCfgMinPollPeriod 1.3.6.1.4.1.449.2.1.2.1.1.29.1.6 integer read-only
The minimum time the TPAD waits between polls. Specified in 50 ms increments (i.e. 1 means 50 ms).
                                       cdx6500GSCPCfgPollRespTimer 1.3.6.1.4.1.449.2.1.2.1.1.29.1.7 integer read-only
The maximum time the TPAD waits for a response from the terminal after a poll. Specified in 50 ms increments (i.e. 5 means 250 ms).
                                       cdx6500GSCPCfgAckTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.8 integer read-only
The maximum time the TPAD or HPAD waits for acknowledgement for a transmitted frame. Specified in 50 ms increments (i.e. 5 means 250 ms).
                                       cdx6500GSCPCfgInterCharTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.9 integer read-only
The maximum time period allowed between received characters. Specified in 50 ms increments (i.e. 5 means 250 ms).
                                       cdx6500GSCPCfgBroadcastHoldTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.10 integer read-only
The time the TPAD holds a broadcast frame from one station, when it detects a dropped frame, while waiting for the missing frame from another station. Specified in 50 ms increments (i.e. 5 means 250 ms).
                                       cdx6500GSCPCfgSolicitedTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.11 integer read-only
Specifies the time that the TPAD waits for a SAD message in response to a PAD message, before re-transmitting the PAD message. Specified in 50 ms increments (i.e. 60 means 3 seconds).
                                       cdx6500GSCPCfgIdleDiscTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.12 integer read-only
The period that the HPAD waits to receive a UAD-frame, SAD-frame or poll from the polling controller before clearing the call to the TPAD. Specified in minutes (i.e. 5 means 5 minutes).
                                       cdx6500GSCPCfgAutocallRetryTimeOut 1.3.6.1.4.1.449.2.1.2.1.1.29.1.13 integer read-only
Specifies the time to wait between subsequent autocall attempts. Specified in 50 ms increments. (i.e. 4 means 200 ms).
                                       cdx6500GSCPCfgMaxAutocallRetries 1.3.6.1.4.1.449.2.1.2.1.1.29.1.14 integer read-only
The maximum number of autocall attempts allowed. The port is disabled when the limit is reached.
                                       cdx6500GSCPCfgN1 1.3.6.1.4.1.449.2.1.2.1.1.29.1.15 integer read-only
The number of good responses a TPAD must receive before changing a stations state from UP to DOWN .
                                       cdx6500GSCPCfgN2 1.3.6.1.4.1.449.2.1.2.1.1.29.1.16 integer read-only
The number of good responses a TPAD must receive before changing a stations state from DOWN to UP.
                                       cdx6500GSCPCfgNumRetries 1.3.6.1.4.1.449.2.1.2.1.1.29.1.17 integer read-only
The number of times the TPAD or HPAD will retry a selection procedure before discarding a frame.
                                       cdx6500GSCPCfgPortAddress 1.3.6.1.4.1.449.2.1.2.1.1.29.1.18 displaystring read-only
When a GSC port makes a call,this address is inserted into the calling address field.
                                       cdx6500GSCPCfgPortOptions 1.3.6.1.4.1.449.2.1.2.1.1.29.1.19 displaystring read-only
The port options specified : NONE - No option specified.
                                       cdx6500GSCPCfgConnType 1.3.6.1.4.1.449.2.1.2.1.1.29.1.20 integer read-only
Specifies the control signal handshake and clocking required for a connection to be made to this port. simp - simple, no control signals required. simpa - CTS follows RTS, but no control signals required. nc - Skipped during configuration. Enumeration: 'simpa': 16, 'simp': 1, 'nc': 100.
                                       cdx6500GSCPCfgWakeUpTimer 1.3.6.1.4.1.449.2.1.2.1.1.29.1.21 integer read-only
Specifies the time to wait after autocall attempts are exhausted before attempting another autocall cycle. A value of 0 will prevent subsequent attempts until the station is booted.
                                       cdx6500GSCPCfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.29.1.22 integer read-only
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled Enumeration: 'none': 5, 'x21': 4, 'v35': 2, 'v36': 3, 'v24': 1.
                                       cdx6500GSCPCfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.29.1.23 integer read-only
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal Enumeration: 'tm': 2, 'ri': 1.
                                       cdx6500GSCPCfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.29.1.24 integer read-only
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable Enumeration: 'none': 1, 'xover': 2.
                         cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
                             cdx6500SPCTGSCStationTable 1.3.6.1.4.1.449.2.1.2.1.3.8 no-access
This table contains GSC station configuration parameters.
                                 cdx6500SPCTGSCStationEntry 1.3.6.1.4.1.449.2.1.2.1.3.8.1 no-access
Each StationEntry contains the configuration parameters for one GSC station.
                                     cdx6500GSCSCfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.3.8.1.1 integer read-only
Port number of the port being used by GSC.
                                     cdx6500GSCSCfgStationNumber 1.3.6.1.4.1.449.2.1.2.1.3.8.1.2 integer read-only
The number of devices on the multidrop line. Also used for routing purposes.
                                     cdx6500GSCSCfgStationAddress 1.3.6.1.4.1.449.2.1.2.1.3.8.1.3 integer read-only
The device address on the local line.
                                     cdx6500GSCSCfgRemoteAddress 1.3.6.1.4.1.449.2.1.2.1.3.8.1.4 integer read-only
The device address on the remote line.
                                     cdx6500GSCSCfgAutocallMnem 1.3.6.1.4.1.449.2.1.2.1.3.8.1.5 displaystring read-only
Identifies the entry in the Autocall Mnemonic table which specifies the X.25 call request parameters for this station.This is valid only if the port subtype is HPAD.
                                     cdx6500GSCSCfgProtocolId 1.3.6.1.4.1.449.2.1.2.1.3.8.1.6 displaystring read-only
The protocol ID inserted in outgoing calls and checked for incoming calls.
                                     cdx6500GSCSCfgBillingRecords 1.3.6.1.4.1.449.2.1.2.1.3.8.1.7 integer read-only
billingOff - Billing records are not generated. billingOn - Billing records are generated. Enumeration: 'billingOff': 1, 'billingOn': 2.
                                     cdx6500GSCSCfgStationOptions 1.3.6.1.4.1.449.2.1.2.1.3.8.1.8 displaystring read-only
GSC station options: NONE - no option specified IBRO - Inband Broadcast frames supported on this channel. One or more options may be specified by summing (separating them by a plus sign).
                 cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
                     cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
                         cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
                             cdx6500PPSTGSCPortTable 1.3.6.1.4.1.449.2.1.3.1.1.30 no-access
This table holds statistics items for GSC ports.
                                   cdx6500PPSTGSCPortEntry 1.3.6.1.4.1.449.2.1.3.1.1.30.1 no-access
Statistics parameters pertaining to GSC Ports.
                                       cdx6500GSCPStatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.30.1.1 integer read-only
The port number of the GSC port.
                                       cdx6500GSCPStatPortType 1.3.6.1.4.1.449.2.1.3.1.1.30.1.2 integer read-only
The port type. Enumeration: 'gsc': 51.
                                       cdx6500GSCPStatSubtype 1.3.6.1.4.1.449.2.1.3.1.1.30.1.3 integer read-only
The port sub-type. gscHpad - port is functioning as a host PAD. gscTpad - Port is functioning as a terminal PAD. Enumeration: 'gscTpad': 1, 'gscHpad': 2.
                                       cdx6500GSCPStatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.30.1.4 integer read-only
Status of the port: disabled - Port is disabled. enabled - Port is enabled. busyOut - The port is busied out. up - At least one station on the port is not down or disabled. down - All stations on the port are either down or disabled. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility. Enumeration: 'down': 4, 'busyOut': 2, 'enabled': 1, 'up': 3, 'disabled': 0, 'newvalDisabled': 50.
                                       cdx6500GSCPStatPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.30.1.5 integer read-only
The measured port speed in bits per second.
                                       cdx6500GSCPStatLastStatsReset 1.3.6.1.4.1.449.2.1.3.1.1.30.1.6 displaystring read-only
The time when the port statistics were last reset.
                                       cdx6500GSCPStatCharsIn 1.3.6.1.4.1.449.2.1.3.1.1.30.1.7 counter read-only
Number of characters received on the line, including data and control characters.
                                       cdx6500GSCPStatCharsOut 1.3.6.1.4.1.449.2.1.3.1.1.30.1.8 counter read-only
Number of characters transmitted on the line, including data and control characters.
                                       cdx6500GSCPStatCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.30.1.9 integer read-only
Number of characters received per second on the line, including data and control characters.
                                       cdx6500GSCPStatCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.30.1.10 integer read-only
Number of characters transmitted per second on the line, including data and control characters.
                                       cdx6500GSCPStatOverrunErrs 1.3.6.1.4.1.449.2.1.3.1.1.30.1.11 counter read-only
The number of overrun errors detected on the line.
                                       cdx6500GSCPStatChecksumErrs 1.3.6.1.4.1.449.2.1.3.1.1.30.1.12 counter read-only
The number of frames received with checksum errors.
                                       cdx6500GSCPStatOverlengthFrames 1.3.6.1.4.1.449.2.1.3.1.1.30.1.13 counter read-only
The number of frames received that were over length.
                                       cdx6500GSCPStatPollRespTimeOuts 1.3.6.1.4.1.449.2.1.3.1.1.30.1.14 counter read-only
The number of times a poll was issued without response from the terminal.
                                       cdx6500GSCPStatIntercharTimeOuts 1.3.6.1.4.1.449.2.1.3.1.1.30.1.15 counter read-only
The number of receive frames aborted because of inter-character timeouts.
                                       cdx6500GSCPStatAckTimeOuts 1.3.6.1.4.1.449.2.1.3.1.1.30.1.16 counter read-only
The number of transmitted frames which were not acknowledged.
                                       cdx6500GSCPStatPADFrames 1.3.6.1.4.1.449.2.1.3.1.1.30.1.17 counter read-only
The number of PAD frames received (TPAD) or transmitted (HPAD).
                                       cdx6500GSCPStatSADFrames 1.3.6.1.4.1.449.2.1.3.1.1.30.1.18 counter read-only
The number of SAD frames transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatUADFrames 1.3.6.1.4.1.449.2.1.3.1.1.30.1.19 counter read-only
The number of UAD frames transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatBROFrames 1.3.6.1.4.1.449.2.1.3.1.1.30.1.20 counter read-only
The number of BRO frames transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatPADChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.21 counter read-only
The number of PAD characters received (TPAD) or transmitted (HPAD).
                                       cdx6500GSCPStatSADChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.22 counter read-only
The number of SAD characters transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatUADChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.23 counter read-only
The number of UAD characters transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatENQs 1.3.6.1.4.1.449.2.1.3.1.1.30.1.24 counter read-only
The number of ENQ characters received (TPAD) or transmitted (HPAD).
                                       cdx6500GSCPStatPACChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.25 counter read-only
The number of PAC characters received (TPAD) or transmitted (HPAD).
                                       cdx6500GSCPStatSACChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.26 counter read-only
The number of SAC characters transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatUACChars 1.3.6.1.4.1.449.2.1.3.1.1.30.1.27 counter read-only
The number of UAC characters transmitted (TPAD) or received (HPAD).
                                       cdx6500GSCPStatPolls 1.3.6.1.4.1.449.2.1.3.1.1.30.1.28 counter read-only
The number of polls transmitted (TPAD) or received (HPAD).
                         cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
                             cdx6500SPSTGSCStationTable 1.3.6.1.4.1.449.2.1.3.1.3.7 no-access
Statistics parameters relevant to GSC stations.
                                 cdx6500SPSTGSCStationEntry 1.3.6.1.4.1.449.2.1.3.1.3.7.1 no-access
This table holds statistics parameters pertaining to GSC stations.
                                     cdx6500GSCSStatPortNumber 1.3.6.1.4.1.449.2.1.3.1.3.7.1.1 integer read-only
The port number of the GSC port.
                                     cdx6500GSCSStatStationNum 1.3.6.1.4.1.449.2.1.3.1.3.7.1.2 integer read-only
The GSC station number.
                                     cdx6500GSCSStatPortType 1.3.6.1.4.1.449.2.1.3.1.3.7.1.3 integer read-only
This indicates the port type. Enumeration: 'gsc': 51.
                                     cdx6500GSCSStatSubtype 1.3.6.1.4.1.449.2.1.3.1.3.7.1.4 integer read-only
Indicates the sub-type of the associated port. gscHpad - Associated port is functioning as a host PAD. gscTpad - Associated port is functioning as a terminal PAD. Enumeration: 'gscTpad': 1, 'gscHpad': 2.
                                     cdx6500GSCSStatStationAddress 1.3.6.1.4.1.449.2.1.3.1.3.7.1.5 integer read-only
Configure station address.
                                     cdx6500GSCSStatStationStatus 1.3.6.1.4.1.449.2.1.3.1.3.7.1.6 integer read-only
The station status: disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busied out. up - Station is up. down - Station is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility. Enumeration: 'down': 4, 'busyOut': 2, 'enabled': 1, 'up': 3, 'disabled': 0, 'newvalDisabled': 50.
                                     cdx6500GSCSStatLastStatsReset 1.3.6.1.4.1.449.2.1.3.1.3.7.1.7 displaystring read-only
Time when the station statistics were last reset.
                                     cdx6500GSCSStatCharsIn 1.3.6.1.4.1.449.2.1.3.1.3.7.1.8 counter read-only
Number of characters received on the line, including data and control characters.
                                     cdx6500GSCSStatCharsOut 1.3.6.1.4.1.449.2.1.3.1.3.7.1.9 counter read-only
Number of characters transmitted on the line, including data and control characters.
                                     cdx6500GSCSStatCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.7.1.10 integer read-only
Number of characters received per second on the line, including data and control characters.
                                     cdx6500GSCSStatCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.7.1.11 integer read-only
Number of characters transmitted per second on the line, including data and control characters.
                                     cdx6500GSCSStatChecksumErrs 1.3.6.1.4.1.449.2.1.3.1.3.7.1.12 counter read-only
The number of frames received with checksum errors.
                                     cdx6500GSCSStatOverlengthFrames 1.3.6.1.4.1.449.2.1.3.1.3.7.1.13 counter read-only
The number of frames received that were overlength.
                                     cdx6500GSCSStatPollRespTimeOuts 1.3.6.1.4.1.449.2.1.3.1.3.7.1.14 counter read-only
The number of times a poll was issued without response from the terminal (TPAD only).
                                     cdx6500GSCSStatIntercharTimeOuts 1.3.6.1.4.1.449.2.1.3.1.3.7.1.15 counter read-only
The number of receive frames aborted because of inter-character timeouts.
                                     cdx6500GSCSStatAckTimeOuts 1.3.6.1.4.1.449.2.1.3.1.3.7.1.16 counter read-only
The number of transmitted frames which were not acknowledged.
                                     cdx6500GSCSStatPADFrames 1.3.6.1.4.1.449.2.1.3.1.3.7.1.17 counter read-only
The number of PAD frames received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatSADFrames 1.3.6.1.4.1.449.2.1.3.1.3.7.1.18 counter read-only
The number of SAD frames transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatUADFrames 1.3.6.1.4.1.449.2.1.3.1.3.7.1.19 counter read-only
The number of UAD frames transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatBROFrames 1.3.6.1.4.1.449.2.1.3.1.3.7.1.20 counter read-only
The number of BRO frames transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatPADChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.21 counter read-only
The number of PAD characters received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatSADChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.22 counter read-only
The number of SAD characters transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatUADChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.23 counter read-only
The number of UAD characters transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatENQ 1.3.6.1.4.1.449.2.1.3.1.3.7.1.24 counter read-only
The number of ENQ characters received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatPACChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.25 counter read-only
The number of PAC characters received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatSACChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.26 counter read-only
The number of SAC characters transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatUACChars 1.3.6.1.4.1.449.2.1.3.1.3.7.1.27 counter read-only
The number of UAC characters transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatPolls 1.3.6.1.4.1.449.2.1.3.1.3.7.1.28 counter read-only
The number of Polls transmitted (TPAD) or received (HPAD).
                                     cdx6500GSCSStatPADMessages 1.3.6.1.4.1.449.2.1.3.1.3.7.1.29 counter read-only
The number of PAD Messages received (HPAD) or transmitted (TPAD).
                                     cdx6500GSCSStatUADMessages 1.3.6.1.4.1.449.2.1.3.1.3.7.1.30 counter read-only
The number of UAD Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatSADMessages 1.3.6.1.4.1.449.2.1.3.1.3.7.1.31 counter read-only
The number of SAD Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatBROMessages 1.3.6.1.4.1.449.2.1.3.1.3.7.1.32 counter read-only
The number of BRO Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatSolicitAbort 1.3.6.1.4.1.449.2.1.3.1.3.7.1.33 counter read-only
The number of SOLICIT ABORT Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatStatusEnq 1.3.6.1.4.1.449.2.1.3.1.3.7.1.34 counter read-only
The number of STATUS ENQ Messages received (HPAD) or transmitted (TPAD).
                                     cdx6500GSCSStatDeviceUp 1.3.6.1.4.1.449.2.1.3.1.3.7.1.35 counter read-only
The number of DEVICE UP Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatDeviceDown 1.3.6.1.4.1.449.2.1.3.1.3.7.1.36 counter read-only
The number of DEVICE DOWN Messages received (TPAD) or transmitted (HPAD).
                                     cdx6500GSCSStatCallCurrentStatus 1.3.6.1.4.1.449.2.1.3.1.3.7.1.37 integer read-only
The current status of the call. inhibited :Current Status = Disconnected. disconnected :Current Status = Disconnected. calling :Current Status = Calling. called :Current Status = Called. connected :Current Status = Connected (data transfer). notDefined :Current Status = Undefined. Enumeration: 'disconnected': 2, 'calling': 3, 'inhibited': 1, 'connected': 5, 'notDefined': 6, 'called': 4.
                                     cdx6500GSCSStatLastClrCauseCode 1.3.6.1.4.1.449.2.1.3.1.3.7.1.38 displaystring read-only
Last clear cause code.
                                     cdx6500GSCSStatLastClrDiagCode 1.3.6.1.4.1.449.2.1.3.1.3.7.1.39 displaystring read-only
Last clear diagnostic code.
                                     cdx6500GSCSStatLastInCalledAddress 1.3.6.1.4.1.449.2.1.3.1.3.7.1.40 displaystring read-only
The called address in the last inbound call.
                                     cdx6500GSCSStatLastInCallingAddress 1.3.6.1.4.1.449.2.1.3.1.3.7.1.41 displaystring read-only
The calling address in the last inbound call.
                                     cdx6500GSCSStatLastInCallFacilities 1.3.6.1.4.1.449.2.1.3.1.3.7.1.42 displaystring read-only
The facilities in the last inbound call.
                                     cdx6500GSCSStatLastInCallCUD 1.3.6.1.4.1.449.2.1.3.1.3.7.1.43 displaystring read-only
The Call User Data in the last inbound call.
                                     cdx6500GSCSStatLastOutCalledAddress 1.3.6.1.4.1.449.2.1.3.1.3.7.1.44 displaystring read-only
The called address in the last outbound call.
                                     cdx6500GSCSStatLastOutCallingAddress 1.3.6.1.4.1.449.2.1.3.1.3.7.1.45 displaystring read-only
The calling address in the last outbound call.
                                     cdx6500GSCSStatLastOutCallFacilities 1.3.6.1.4.1.449.2.1.3.1.3.7.1.46 displaystring read-only
The facilities in the last outbound call.
                                     cdx6500GSCSStatLastOutCallCUD 1.3.6.1.4.1.449.2.1.3.1.3.7.1.47 displaystring read-only
The Call User Data in the last outbound call.
                 cdx6500Controls 1.3.6.1.4.1.449.2.1.4
                     cdx6500ContGSC 1.3.6.1.4.1.449.2.1.4.12
                           cdx6500ContGSCPTable 1.3.6.1.4.1.449.2.1.4.12.1 no-access
This table contains the port control objects
                               cdx6500ContGSCPTableEntry 1.3.6.1.4.1.449.2.1.4.12.1.1 no-access
Each entry represents a port control parameter.
                                   cdx6500ContGSCPPortNum 1.3.6.1.4.1.449.2.1.4.12.1.1.1 integer no-access
GSC port Number.
                                   cdx6500ContGSCPBootPort 1.3.6.1.4.1.449.2.1.4.12.1.1.2 integer read-write
Boot the specified GSC port. boot : Boot the port noBoot : Do not boot the port. Enumeration: 'boot': 1, 'noBoot': 2.
                                   cdx6500ContGSCPEnablePort 1.3.6.1.4.1.449.2.1.4.12.1.1.3 integer read-write
Enable the specified GSC port. enable : Enable the GSC port. noEnable : Do not enable the GSC port. Enumeration: 'noEnable': 2, 'enable': 1.
                                   cdx6500ContGSCPDisablePort 1.3.6.1.4.1.449.2.1.4.12.1.1.4 integer read-write
Disable the specified GSC port. disable : Disable the GSC port. noDisable : Do not disable the GSC port. Enumeration: 'noDisable': 2, 'disable': 1.
                           cdx6500ContGSCSTable 1.3.6.1.4.1.449.2.1.4.12.2 no-access
This table contains the station control objects.
                               cdx6500ContGSCSTableEntry 1.3.6.1.4.1.449.2.1.4.12.2.1 no-access
Each entry represents a station control parameter.
                                   cdx6500ContGSCSPortNum 1.3.6.1.4.1.449.2.1.4.12.2.1.1 integer no-access
The GSC Port Number.
                                   cdx6500ContGSCSStnNum 1.3.6.1.4.1.449.2.1.4.12.2.1.2 integer no-access
The GSC Station Number.
                                   cdx6500ContGSCSBootStation 1.3.6.1.4.1.449.2.1.4.12.2.1.3 integer read-write
Boot the specified GSC station boot : Boot the station. noBoot : Do not boot the station. Enumeration: 'boot': 1, 'noBoot': 2.
                                   cdx6500ContGSCSEnableStation 1.3.6.1.4.1.449.2.1.4.12.2.1.4 integer read-write
Enable the specified GSC station. enable : Enable the Station. noEnable : Do not enable the Station. Enumeration: 'noEnable': 2, 'enable': 1.
                                   cdx6500ContGSCSDisableStation 1.3.6.1.4.1.449.2.1.4.12.2.1.5 integer read-write
Disable the specified GSC station. disable : Disable the station. noDisable : Do not disable the station. Enumeration: 'noDisable': 2, 'disable': 1.