GDCSC613-MIB: View SNMP OID List / Download MIB

VENDOR: GENERAL DATACOMM


 Home MIB: GDCSC613-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gdc 1.3.6.1.4.1.498
         bql2 1.3.6.1.4.1.498.12
               bql613 1.3.6.1.4.1.498.12.1
                   bql613MIBVersion 1.3.6.1.4.1.498.12.1.1 displaystring read-only
The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.
                   bql613WhatAreYouTable 1.3.6.1.4.1.498.12.1.2 no-access
The GDC SC613 What Are You Table.
                       bql613WhatAreYouEntry 1.3.6.1.4.1.498.12.1.2.1 no-access
An entry in the GDC SC613 What Are You table.
                           bql613WhatAreYouIndex 1.3.6.1.4.1.498.12.1.2.1.1 scinstance read-only
This object is the identifier of the SC613 What Are You table.
                           bql613CodeRev 1.3.6.1.4.1.498.12.1.2.1.2 displaystring read-only
This function returns the firmware code level. Example A- ,B-
                           bql613AlarmStatus 1.3.6.1.4.1.498.12.1.2.1.3 octet string read-only
The current alarms of the unit without the alarm masks.
                   bql613ConfigTable 1.3.6.1.4.1.498.12.1.3 no-access
The GDC SC613.
                       bql613ConfigEntry 1.3.6.1.4.1.498.12.1.3.1 no-access
A listing of GDC 2B1Q SC613 options.
                           bql613ConfigIndex 1.3.6.1.4.1.498.12.1.3.1.1 scinstance read-only
A unique index for the Configuration Table.
                           bql613TestPattern 1.3.6.1.4.1.498.12.1.3.1.2 integer read-write
Object to select loop and channel test pattern for SC613. Enumeration: 'pattern2047': 1, 'pattern511': 2.
                           bql613RLTimeout 1.3.6.1.4.1.498.12.1.3.1.3 integer read-write
Object to select remote loop time out. Enumeration: 'timeoutAfter10Min': 2, 'noTimeout': 1.
                           bql613MasterTXClkSrc 1.3.6.1.4.1.498.12.1.3.1.4 integer read-write
Object to option the Loop master transmit clock source. Enumeration: 'internal': 1, 'external': 2.
                           bql613DTEDataRate 1.3.6.1.4.1.498.12.1.3.1.5 integer read-write
Object to option a SC613 Loop interface to a K bit per second rate. Enumeration: 'kBps128000': 10, 'kBps64000': 9.
                           bql613RespRdl 1.3.6.1.4.1.498.12.1.3.1.6 integer read-write
Object to option V54 Response RDL to enable or disable. Enumeration: 'enable': 1, 'disable': 2.
                   bql613DiagnosticTable 1.3.6.1.4.1.498.12.1.4 no-access
The GDC SC613 diagnostics table.
                       bql613DiagnosticEntry 1.3.6.1.4.1.498.12.1.4.1 no-access
A listing of GDC SC613 diagnostic tests
                           bql613DiagnosticIndex 1.3.6.1.4.1.498.12.1.4.1.1 scinstance read-only
A unique index for the Diagnostic Table.
                           bql613DiagnosticTest 1.3.6.1.4.1.498.12.1.4.1.2 integer read-write
This function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest 16 = line loopback test 32 = terminate test All other values are test combinations such as 9 = selftest and remote loopback.
                           bql613DiagnosticActive 1.3.6.1.4.1.498.12.1.4.1.3 integer read-only
This function represents the test condition. Enumeration: 'notActive': 1, 'active': 2.
                           bql613DiagnosticResults 1.3.6.1.4.1.498.12.1.4.1.4 integer read-only
This function reads the self test results in bit errors.
                           bql613DiagnosticErrorCount 1.3.6.1.4.1.498.12.1.4.1.5 integer read-write
This function resets the selftest error count for a SC613. Enumeration: 'reset': 2, 'normal': 1.
                   bql613ControlTable 1.3.6.1.4.1.498.12.1.6 no-access
The GDC SC613 Control Table.
                       bql613ControlEntry 1.3.6.1.4.1.498.12.1.6.1 no-access
An entry in the GDC SC613 Control table.
                           bql613ControlIndex 1.3.6.1.4.1.498.12.1.6.1.1 scinstance read-only
This object is the identifier of the SC613 Control table.
                           bql613SoftReset 1.3.6.1.4.1.498.12.1.6.1.2 integer read-write
Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only. Enumeration: 'reset': 2, 'normal': 1.
                           bql613EraseConfig 1.3.6.1.4.1.498.12.1.6.1.3 integer read-write
Forces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only. Enumeration: 'erase': 2, 'normal': 1.
                           bql613FrontPanel 1.3.6.1.4.1.498.12.1.6.1.4 integer read-write
Object used to enable or disable the units front panel switches. Enumeration: 'enable': 1, 'disable': 2.
                           bql613LEDStatus 1.3.6.1.4.1.498.12.1.6.1.5 octet string read-only
The GDC SC613 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - alarm on 1.4 - loop 1 line loopback 1.3 - loop 1 send data transitions 1.2 - loop 1 receive data transitions 1.1 - loop 1 request to send 1.0 - loop 1 data carrier on 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - loop 2 line loopback 2.3 - loop 2 send data transitions 2.2 - loop 2 receive data transitions 2.1 - loop 2 request to send 2.0 - loop 2 data carrier on 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - loop 3 line loopback 3.3 - loop 3 send data transitions 3.2 - loop 3 receive data transitions 3.1 - loop 3 request to send 3.0 - loop 3 data carrier on
                   bql613CurrentTable 1.3.6.1.4.1.498.12.1.7 no-access
The SC613 Current table.
                       bql613CurrentEntry 1.3.6.1.4.1.498.12.1.7.1 no-access
An entry in the SC613 Current table.
                           bql613CurrentIndex 1.3.6.1.4.1.498.12.1.7.1.1 scinstance read-only
The index value which uniquely identifies the SC613 interface to which this entry is applicable.
                           bql613CurrentStats 1.3.6.1.4.1.498.12.1.7.1.2 octet string read-only
The number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval.
                   bql613IntervalTable 1.3.6.1.4.1.498.12.1.8 no-access
The SC613 Interval table.
                       bql613IntervalEntry 1.3.6.1.4.1.498.12.1.8.1 no-access
An entry in the SC613 Interval table.
                           bql613IntervalIndex 1.3.6.1.4.1.498.12.1.8.1.1 scinstance read-only
The index value which uniquely identifies the ISDN interface to which this entry is applicable.
                           bql613IntervalNumber 1.3.6.1.4.1.498.12.1.8.1.2 integer read-only
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that all 96 intervals are valid).
                           bql613IntervalStats 1.3.6.1.4.1.498.12.1.8.1.3 octet string read-only
The number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
                   bql613TotalTable 1.3.6.1.4.1.498.12.1.9 no-access
The SC613 Total table. 24 hour interval.
                       bql613TotalEntry 1.3.6.1.4.1.498.12.1.9.1 no-access
An entry in the SC613 Total table.
                           bql613TotalIndex 1.3.6.1.4.1.498.12.1.9.1.1 scinstance read-only
The index value which uniquely identifies the ISDN interface to which this entry is applicable.
                           bql613TotalStats 1.3.6.1.4.1.498.12.1.9.1.2 octet string read-only
The number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval.
                   bql613IntervalMaintenanceTable 1.3.6.1.4.1.498.12.1.10 no-access
The SC613 Loop Interval Maintenance table.
                         bql613IntervalMaintenanceEntry 1.3.6.1.4.1.498.12.1.10.1 no-access
The SC613 Interval Maintenance table entry.
                             bql613IntervalMaintenanceIndex 1.3.6.1.4.1.498.12.1.10.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, where is can be 1, 2, or 3.
                             bql613ResetIntervals 1.3.6.1.4.1.498.12.1.10.1.2 integer read-write
This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero. Enumeration: 'reset': 2, 'norm': 1.
                             bql613NumberofValidIntervals 1.3.6.1.4.1.498.12.1.10.1.3 integer read-only
This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.
                             bql613ResetMajorAlarm 1.3.6.1.4.1.498.12.1.10.1.4 integer read-write
This variable is used to reset alarm per Loop basis. Enumeration: 'reset': 1, 'norm': 2.
                             bql613ResetMinorAlarm 1.3.6.1.4.1.498.12.1.10.1.5 integer read-write
This variable is used to reset alarm per Loop basis. Enumeration: 'reset': 1, 'norm': 2.
               bql613Alarm 1.3.6.1.4.1.498.12.7
                   bql613AlarmData 1.3.6.1.4.1.498.12.7.1
                       bql613NoResponseAlm 1.3.6.1.4.1.498.12.7.1.1
                       bql613DiagRxErrAlm 1.3.6.1.4.1.498.12.7.1.2
                       bql613PowerUpAlm 1.3.6.1.4.1.498.12.7.1.3
                       bql613Lp2B1QOutofSyncAlm 1.3.6.1.4.1.498.12.7.1.4
                       bql613LpTxClockOutOfTolerance 1.3.6.1.4.1.498.12.7.1.5
                       bql613LpExtTxClkAlm 1.3.6.1.4.1.498.12.7.1.6
                       bql613LpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.7.1.7
                       bql613LpMajorBERAlm 1.3.6.1.4.1.498.12.7.1.8
                       bql613LpMinorBERAlm 1.3.6.1.4.1.498.12.7.1.9
                   bql613AlarmConfigTable 1.3.6.1.4.1.498.12.7.2 no-access
The bql613AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
                       bql613AlarmConfigEntry 1.3.6.1.4.1.498.12.7.2.1 no-access
An entry in the bql613AlarmConfigTable table.
                           bql613AlarmConfigIndex 1.3.6.1.4.1.498.12.7.2.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable.
                           bql613AlarmConfigIdentifier 1.3.6.1.4.1.498.12.7.2.1.2 object identifier read-only
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
                           bql613AlarmThreshold 1.3.6.1.4.1.498.12.7.2.1.3 integer read-write
This function sets/reads the Major or Minor BER alarm threshold criteria. Enumeration: 'thres10E04': 2, 'thres10E05': 3, 'thres10E06': 4, 'thres10E03': 1.