Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gdc 1.3.6.1.4.1.498
         datx 1.3.6.1.4.1.498.7
             datxSystem 1.3.6.1.4.1.498.7.1
                 datxVersion 1.3.6.1.4.1.498.7.1.1
                     datxMIBversion 1.3.6.1.4.1.498.7.1.1.1 displaystring read-only
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present.
                 datxMaintenance 1.3.6.1.4.1.498.7.1.2
                     datxMaintTable 1.3.6.1.4.1.498.7.1.2.1 no-access
This table describes the maintenance objects for the unit
                         datxMaintEntry 1.3.6.1.4.1.498.7.1.2.1.1 no-access
An entry in the GDC Datx Maintenance Table.
                             datxMaintIndex 1.3.6.1.4.1.498.7.1.2.1.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxFirmwareRev 1.3.6.1.4.1.498.7.1.2.1.1.2 displaystring read-only
The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99.
                             datxDefaultInit 1.3.6.1.4.1.498.7.1.2.1.1.3 integer read-write
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a reset to make the default configuration take affect. The value of normal(1) will be returned when the initialization is complete. Enumeration: 'factoryDefault': 2, 'normal': 1.
                             datxFrontPanel 1.3.6.1.4.1.498.7.1.2.1.1.4 integer read-write
This variable is used to indicate whether the front panel switches are operational or not. 'inhibit' refers to when the front panel switches are not operational. 'enable' refers to when the front panel switches are operational. Enumeration: 'inhibit': 1, 'enable': 2.
                             datxLedStatus 1.3.6.1.4.1.498.7.1.2.1.1.5 octet string read-only
Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - RD bit 4 - SD bit 3 - CS bit 2 - CO bit 1 - ALM bit 0 - TM Octet 2 bit 7 - not used bit 6 - ST bit 5 - LL bit 4 - RDL bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - future use
                 datxConfiguration 1.3.6.1.4.1.498.7.1.3
                     datxTransConfigTable 1.3.6.1.4.1.498.7.1.3.1 no-access
This table describes the DATX transmission mode configuration options
                         datxTransConfigEntry 1.3.6.1.4.1.498.7.1.3.1.1 no-access
An entry in the transmission configuration table
                             datxTransConfigIndex 1.3.6.1.4.1.498.7.1.3.1.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxBaudRate 1.3.6.1.4.1.498.7.1.3.1.1.2 integer read-write
SYNC/ASYNC Mode operation and Baud Rates Enumeration: 'synchronous1200': 2, 'synchronous19200': 8, 'synchronous2400': 3, 'synchronous14400': 7, 'synchronous9600': 6, 'asynchronous': 1, 'synchronous7200': 5, 'synchronous4800': 4.
                             datxSyncTxClockSource 1.3.6.1.4.1.498.7.1.3.1.1.3 integer read-write
Synchronous Tx Clock Configuration Enumeration: 'internal': 1, 'slave': 2, 'external': 3.
                             datxEiaSyncClock 1.3.6.1.4.1.498.7.1.3.1.1.4 integer read-write
Control for the EIA sync clock Enumeration: 'enable': 2, 'disable': 1.
                     datxEiaConfigTable 1.3.6.1.4.1.498.7.1.3.2 no-access
DATX EIA line configuration options
                         datxEiaConfigEntry 1.3.6.1.4.1.498.7.1.3.2.1 no-access
An entry in the EIA config table
                             datxEIAIndex 1.3.6.1.4.1.498.7.1.3.2.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxCarrierControl 1.3.6.1.4.1.498.7.1.3.2.1.2 integer read-write
Enumeration: 'dtr': 1, 'rts': 2.
                             datxRtsMode 1.3.6.1.4.1.498.7.1.3.2.1.3 integer read-write
RTS mode selection Enumeration: 'real': 1, 'forced': 2.
                             datxRtsCtsDelay 1.3.6.1.4.1.498.7.1.3.2.1.4 integer read-write
RTS/CTS Delay time Enumeration: 't8mSec': 1, 't75mSec': 2.
                             datxEiaRdlControl 1.3.6.1.4.1.498.7.1.3.2.1.5 integer read-write
EIA RDL control selection Enumeration: 'disabled': 1, 'enabled': 2.
                             datxDsrInAl 1.3.6.1.4.1.498.7.1.3.2.1.6 integer read-write
Selection for providing DSR will in AL mode Enumeration: 'on': 2, 'off': 1.
                             datxEiaAlControl 1.3.6.1.4.1.498.7.1.3.2.1.7 integer read-write
EIA AL control Enumeration: 'disabled': 1, 'enabled': 2.
                     datxMiscConfigTable 1.3.6.1.4.1.498.7.1.3.3 no-access
DATX misc configuration options
                         datxMiscConfigEntry 1.3.6.1.4.1.498.7.1.3.3.1 no-access
An entry in the misc config table
                             datxMiscIndex 1.3.6.1.4.1.498.7.1.3.3.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxSystemStatusOption 1.3.6.1.4.1.498.7.1.3.3.1.2 integer read-write
Causes to drop CTS in master mode when remote drops line Enumeration: 'disabled': 1, 'enabled': 2.
                             datxDualSignalingTimer 1.3.6.1.4.1.498.7.1.3.3.1.3 integer read-write
Enumeration: 'disable': 1, 'time3Sec': 2, 'immediate': 4, 'time1Sec': 3.
                             datxRegenCharLength 1.3.6.1.4.1.498.7.1.3.3.1.4 integer read-write
Synchronous Tx Clock Configuration Enumeration: 'bits11': 4, 'bits9': 2, 'bits8': 1, 'bits10': 3.
                             datxRegenMode 1.3.6.1.4.1.498.7.1.3.3.1.5 integer read-write
Regen Mode Control Enumeration: 'enable': 1, 'disable': 2.
                             datxAsyncRate 1.3.6.1.4.1.498.7.1.3.3.1.6 integer read-write
Enumeration: 'async9600': 3, 'async4800': 1, 'async7200': 2, 'async19200': 5, 'async14400': 4.
                 datxDiagnostics 1.3.6.1.4.1.498.7.1.4
                     datxDiagnosticsTable 1.3.6.1.4.1.498.7.1.4.1 no-access
DATX diagnostics options
                         datxDiagEntry 1.3.6.1.4.1.498.7.1.4.1.1 no-access
List of Diagnostic Tests and Status Indicators related to the tests
                             datxDiagnosticsIndex 1.3.6.1.4.1.498.7.1.4.1.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxDiagTest 1.3.6.1.4.1.498.7.1.4.1.1.2 integer read-write
Perform diagnostic tests on a unit noTest - stops any test in progress selfTest - sends a selftest pattern analoop - puts the unit into analog loopback analoopSelfTest - puts the unit into analog loopback with a self test pattern remoteDL - performs a remote digital loopback remoteDLselfTest - performs a remote digital loopback with a self test pattern Enumeration: 'remoteDL': 5, 'remoteDLselfTest': 6, 'analoop': 3, 'analoopSelfTest': 4, 'selfTest': 2, 'noTest': 1.
                             datxTestError 1.3.6.1.4.1.498.7.1.4.1.1.3 integer read-only
Test result indicator, shows the results of the last test Enumeration: 'noError': 1, 'testError': 2.
                             datxTestDuration 1.3.6.1.4.1.498.7.1.4.1.1.4 timeticks read-only
Indicates the time duration of any test in progress
                 datxStatus 1.3.6.1.4.1.498.7.1.5
                     datxStatusTable 1.3.6.1.4.1.498.7.1.5.1 no-access
DATX Status indicators
                         datxStatusEntry 1.3.6.1.4.1.498.7.1.5.1.1 no-access
Entry in the status indicator table
                             datxStatusIndex 1.3.6.1.4.1.498.7.1.5.1.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a slot, line, drop, and sub-identifier.
                             datxDTRstatus 1.3.6.1.4.1.498.7.1.5.1.1.2 integer read-only
DTR EIA status indicator Enumeration: 'on': 2, 'off': 1.
                             datxRDLstatus 1.3.6.1.4.1.498.7.1.5.1.1.3 integer read-only
RDL EIA control status indicator Enumeration: 'on': 2, 'off': 1.
                             datxCOstatus 1.3.6.1.4.1.498.7.1.5.1.1.4 integer read-only
CO EIA status indicator Enumeration: 'on': 2, 'off': 1.
                             datxCTSstatus 1.3.6.1.4.1.498.7.1.5.1.1.5 integer read-only
CTS EIA indicator Enumeration: 'on': 2, 'off': 1.
                             datxRTSstatus 1.3.6.1.4.1.498.7.1.5.1.1.6 integer read-only
RTS EIA indicator Enumeration: 'on': 2, 'off': 1.
                             datxTMstatus 1.3.6.1.4.1.498.7.1.5.1.1.7 integer read-only
Test mode EIA indicator Enumeration: 'on': 2, 'off': 1.
                             datxALstatus 1.3.6.1.4.1.498.7.1.5.1.1.8 integer read-only
Analoop EIA status indicator Enumeration: 'on': 2, 'off': 1.
                             datxDSRstatus 1.3.6.1.4.1.498.7.1.5.1.1.9 integer read-only
DSR EIA status indicator Enumeration: 'on': 2, 'off': 1.
                             datxRXclock 1.3.6.1.4.1.498.7.1.5.1.1.10 integer read-only
RxClk activity indicator Enumeration: 'active': 2, 'inactive': 1.
                             datxTXclock 1.3.6.1.4.1.498.7.1.5.1.1.11 integer read-only
TxClk activity indicator Enumeration: 'active': 2, 'inactive': 1.
                             datxEXTclock 1.3.6.1.4.1.498.7.1.5.1.1.12 integer read-only
External clock activity indicator Enumeration: 'active': 2, 'inactive': 1.
                             datxAlarmStatus 1.3.6.1.4.1.498.7.1.5.1.1.13 octet string read-only
The current alarms of the unit without the alarm masks.
             dtx2011 1.3.6.1.4.1.498.7.2
                 dtx2011AlarmData 1.3.6.1.4.1.498.7.2.1
                     dtx2011NoResponseAlm 1.3.6.1.4.1.498.7.2.1.1
                     dtx2011DiagRxErrAlm 1.3.6.1.4.1.498.7.2.1.2
                     dtx2011PowerUpAlm 1.3.6.1.4.1.498.7.2.1.3
                     dtx2011DCDLossAlm 1.3.6.1.4.1.498.7.2.1.4
                     dtx2011NoExtClockAlm 1.3.6.1.4.1.498.7.2.1.5