Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gdc 1.3.6.1.4.1.498
         bql2 1.3.6.1.4.1.498.12
               uas7616 1.3.6.1.4.1.498.12.4
                   uas7616MIBVersion 1.3.6.1.4.1.498.12.4.1 displaystring read-only
The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.
                   uas7616WhatAreYouTable 1.3.6.1.4.1.498.12.4.2 no-access
The GDC 7616 What Are You Table.
                       uas7616WhatAreYouEntry 1.3.6.1.4.1.498.12.4.2.1 no-access
An entry in the GDC 7616 What Are You table.
                           uas7616WhatAreYouIndex 1.3.6.1.4.1.498.12.4.2.1.1 scinstance read-only
This object is the identifier of the 7616 What Are You table.
                           uas7616CodeRev 1.3.6.1.4.1.498.12.4.2.1.2 displaystring read-only
This function returns the firmware code level. Example A- ,B-
                           uas7616AlarmStatus 1.3.6.1.4.1.498.12.4.2.1.3 octet string read-only
The current alarms of the unit without the alarm masks.
                           uas7616SystemTimingGenStatus 1.3.6.1.4.1.498.12.4.2.1.4 integer read-only
Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. Enumeration: 'clk4mhz': 3, 'none': 1, 'clk8khz': 2, 'clk8khzand4mhz': 4.
                   uas7616ConfigTable 1.3.6.1.4.1.498.12.4.3 no-access
The GDC 7616 configuration table.
                       uas7616ConfigEntry 1.3.6.1.4.1.498.12.4.3.1 no-access
A listing of GDC 2B1Q 7616 options.
                           uas7616ConfigIndex 1.3.6.1.4.1.498.12.4.3.1.1 scinstance read-only
A unique index for the Configuration Table.
                           uas7616TXClockSource 1.3.6.1.4.1.498.12.4.3.1.2 integer read-write
Object to select the Transmit Clock Source for the 7616. Enumeration: 'internal': 3, 'system': 1, 'recovered': 2.
                           uas7616TerminationType 1.3.6.1.4.1.498.12.4.3.1.3 integer read-write
Object to select the Termination Type for the 7616. Enumeration: 'lt': 2, 'nt': 1.
                           uas7616ChADataRate 1.3.6.1.4.1.498.12.4.3.1.4 integer read-write
Object to select the Data Rate on Channel A, Loop n. Enumeration: 'kbps64': 1, 'inhibit': 3, 'kbps128': 2.
                           uas7616ChBDataRate 1.3.6.1.4.1.498.12.4.3.1.5 integer read-write
Object to select the Data Rate on Channel B, Loop n. Enumeration: 'kbps64': 1, 'inhibit': 2.
                   uas7616ControlTable 1.3.6.1.4.1.498.12.4.5 no-access
The GDC 7616 Control Table.
                       uas7616ControlEntry 1.3.6.1.4.1.498.12.4.5.1 no-access
An entry in the GDC 7616 Control table.
                           uas7616ControlIndex 1.3.6.1.4.1.498.12.4.5.1.1 scinstance read-only
This object is the identifier of the 7616 Control table.
                           uas7616SoftReset 1.3.6.1.4.1.498.12.4.5.1.2 integer read-write
Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only. Enumeration: 'reset': 2, 'normal': 1.
                           uas7616EraseConfig 1.3.6.1.4.1.498.12.4.5.1.3 integer read-write
Forces an erase of the stored configuration in the network element. The erase selection is write only. Enumeration: 'erase': 2, 'normal': 1.
                           uas7616LEDStatus 1.3.6.1.4.1.498.12.4.5.1.4 octet string read-only
The GDC 7616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - loop 1 channel A (00 = No Change 01 = Green Active) 1.4 - (10 = Red Solid 11 = RedFlashing ) 1.3 - loop 1 channel B (00 = No Change 01 = Green Active) 1.2 - (10 = Red Solid 11 = RedFlashing ) 1.1 - loop 2 channel A (00 = No Change 01 = Green Active) 1.0 - (10 = Red Solid 11 = RedFlashing ) 2.7 - not used 2.6 - not used 2.5 - loop 2 channel B (00 = No Change 01 = Green Active) 2.4 - (10 = Red Solid 11 = RedFlashing ) 2.3 - loop 3 channel A (00 = No Change 01 = Green Active) 2.2 - (10 = Red Solid 11 = RedFlashing ) 2.1 - loop 3 channel B (00 = No Change 01 = Green Active) 2.0 - (10 = Red Solid 11 = RedFlashing ) 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - alarm led 3.3 - test mode led 3.2 - in service 3.1 - system timing source 3.0 - management response
                           uas7616InterfaceType 1.3.6.1.4.1.498.12.4.5.1.5 integer read-write
Object used to configure the transmission interface type. Enumeration: 'notAssigned': 3, 'di': 1, 'ni': 2.
                           uas7616SysTimingGen 1.3.6.1.4.1.498.12.4.5.1.6 integer read-write
Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none. Enumeration: 'none': 1, 'primary': 2, 'secondary': 3.
                           uas7616ResetIntervals 1.3.6.1.4.1.498.12.4.5.1.7 integer read-write
This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero. Enumeration: 'reset': 1, 'normal': 2.
                           uas7616SysUpTime 1.3.6.1.4.1.498.12.4.5.1.8 integer read-only
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.
                           uas7616SetRealTime 1.3.6.1.4.1.498.12.4.5.1.9 integer read-write
Number of seconds from midnight Dec 31, 1969.
                           uas7616ModuleClkSrc 1.3.6.1.4.1.498.12.4.5.1.10 integer read-write
This variable is used to read or set the Module Clock Source. This variable must be system when uas7616SysTimingGen is set to none. Any of the three selections when uas7616SysTimingGen is set to secondary, and internal or recovered when uas7616SysTimingGen is set to primary. Enumeration: 'internal': 2, 'system': 1, 'recovered': 3.
                           uas7616ResetMajorAlarm 1.3.6.1.4.1.498.12.4.5.1.11 integer read-write
This variable is used to reset alarm per Loop basis. Enumeration: 'reset': 1, 'norm': 2.
                           uas7616ResetMinorAlarm 1.3.6.1.4.1.498.12.4.5.1.12 integer read-write
This variable is used to reset alarm per Loop basis. Enumeration: 'reset': 1, 'norm': 2.
                   uas7616DiagnosticTable 1.3.6.1.4.1.498.12.4.6 no-access
The GDC 7616 diagnostics table.
                       uas7616DiagnosticEntry 1.3.6.1.4.1.498.12.4.6.1 no-access
A listing of GDC 7616 diagnostic tests
                           uas7616DiagnosticIndex 1.3.6.1.4.1.498.12.4.6.1.1 scinstance read-only
A unique index for the Diagnostic Table.
                           uas7616DiagnosticChnlIndex 1.3.6.1.4.1.498.12.4.6.1.2 integer read-only
A unique channel index for the Channel the test will run on. Enumeration: 'channelB': 2, 'channelA': 1.
                           uas7616DiagnosticTest 1.3.6.1.4.1.498.12.4.6.1.3 integer read-write
Selections digitalLoopback(2), patternGenTest(3), and unitTest(4) start the associated test when written. Reading will show which (if any) test is active. Writing a stopTestwill stop the test if any was in progress. Enumeration: 'patternGenTest': 3, 'stopTest': 1, 'rdlSelfTest': 6, 'digitalLoopback': 2, 'rdl': 5, 'unitTest': 4.
                           uas7616DiagnosticResetErrorCount 1.3.6.1.4.1.498.12.4.6.1.4 integer read-write
This function resets the error count on a given loop and channel. Management will always read a norm(1) and can only write a reset(2). Enumeration: 'reset': 2, 'norm': 1.
                           uas7616DiagnosticResults 1.3.6.1.4.1.498.12.4.6.1.5 integer read-only
This function reads the self test results in bit errors. 2^20
                   uas7616Current15MinTable 1.3.6.1.4.1.498.12.4.8 no-access
The 7616 15 Min Current table.
                       uas7616Current15MinEntry 1.3.6.1.4.1.498.12.4.8.1 no-access
An entry in the 7616 Current table.
                           uas7616Current15MinIndex 1.3.6.1.4.1.498.12.4.8.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
                           uas7616Current15MinStat 1.3.6.1.4.1.498.12.4.8.1.2 octet string read-only
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 4 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 6 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
                   uas7616IntervalTable 1.3.6.1.4.1.498.12.4.9 no-access
The 7616 Interval table.
                       uas7616IntervalEntry 1.3.6.1.4.1.498.12.4.9.1 no-access
An entry in the Interval table.
                           uas7616IntervalIndex 1.3.6.1.4.1.498.12.4.9.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
                           uas7616IntervalNumber 1.3.6.1.4.1.498.12.4.9.1.2 integer read-only
The number of Errored Seconds, Unavailable Seconds & Severely Errored Seconds encountered in one of the previous 16, individual 15 minute, intervals.
                           uas7616IntervalStat 1.3.6.1.4.1.498.12.4.9.1.3 octet string read-only
Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Interval Octet 3 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 6 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 7 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 9 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 10 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 11 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
                   uas7616Current24HrTable 1.3.6.1.4.1.498.12.4.10 no-access
The Current24Hr table. 4 hour interval.
                         uas7616Current24HrEntry 1.3.6.1.4.1.498.12.4.10.1 no-access
An entry in the Current24Hr table.
                             uas7616Current24HrIndex 1.3.6.1.4.1.498.12.4.10.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
                             uas7616Current24HrStat 1.3.6.1.4.1.498.12.4.10.1.2 octet string read-only
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
                   uas7616Recent24HrTable 1.3.6.1.4.1.498.12.4.11 no-access
The Recent24Hr table. 4 hour interval.
                         uas7616Recent24HrEntry 1.3.6.1.4.1.498.12.4.11.1 no-access
An entry in the Recent24Hr table.
                             uas7616Recent24HrIndex 1.3.6.1.4.1.498.12.4.11.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
                             uas7616Recent24HrStat 1.3.6.1.4.1.498.12.4.11.1.2 octet string read-only
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
                   uas7616UnavailableTimeRegTable 1.3.6.1.4.1.498.12.4.12 no-access
The 7616 Unavailable Time Register table.
                         uas7616UnavailableTimeRegEntry 1.3.6.1.4.1.498.12.4.12.1 no-access
An entry in the Unavailable Time Register table.
                             uas7616UnavailableTimeRegIndex 1.3.6.1.4.1.498.12.4.12.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
                             uas7616UnavailableTimeRegNumber 1.3.6.1.4.1.498.12.4.12.1.2 integer read-only
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
                             uas7616UnavailableTimeRegStart 1.3.6.1.4.1.498.12.4.12.1.3 integer read-only
Start time of one of the Unavailable Time Registers.
                             uas7616UnavailableTimeRegStop 1.3.6.1.4.1.498.12.4.12.1.4 integer read-only
Stop time of one of the Unavailable Time Registers.
                   uas7616IntervalMaintenanceTable 1.3.6.1.4.1.498.12.4.13 no-access
The 7616 Loop Interval Maintenance table.
                         uas7616IntervalMaintenanceEntry 1.3.6.1.4.1.498.12.4.13.1 no-access
The 7616 Interval Maintenance table entry.
                             uas7616IntervalMaintenanceIndex 1.3.6.1.4.1.498.12.4.13.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface.
                             uas7616NumberofValidIntervals 1.3.6.1.4.1.498.12.4.13.1.2 integer read-only
This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.
                   uas7616LocalAlarmConfigTable 1.3.6.1.4.1.498.12.4.14 no-access
The 7616LocalAlarmConfigTable contains entries that configure alarm reporting.
                         uas7616LocalAlarmConfigEntry 1.3.6.1.4.1.498.12.4.14.1 no-access
An entry in the GDC Local Alarm Configuration table.
                             uas7616LocalAlarmConfigIndex 1.3.6.1.4.1.498.12.4.14.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable.
                             uas7616LocalLossOfClock 1.3.6.1.4.1.498.12.4.14.1.2 integer read-write
Disables or enables the Loss of Clock alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LocalUAS 1.3.6.1.4.1.498.12.4.14.1.3 integer read-write
Disables or enables the UAS alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LocalSES 1.3.6.1.4.1.498.12.4.14.1.4 integer read-write
Disables or enables the SES alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LocalES 1.3.6.1.4.1.498.12.4.14.1.5 integer read-write
Disables or enables the ES alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LocalOutOfSync 1.3.6.1.4.1.498.12.4.14.1.6 integer read-write
Disables or enables the Out of Sync alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LocalNoSealingCurrent 1.3.6.1.4.1.498.12.4.14.1.7 integer read-write
Disables or enables the No Sealing Current alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LPMajor 1.3.6.1.4.1.498.12.4.14.1.8 integer read-write
Disables or enables the Major alarm on the Major buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                             uas7616LPMinor 1.3.6.1.4.1.498.12.4.14.1.9 integer read-write
Disables or enables the Minor alarm on the Minor buss or Minor buss. Enumeration: 'disabled': 1, 'enabledMinor': 3, 'enabledMajor': 2.
                   uas7616TSAssignTable 1.3.6.1.4.1.498.12.4.15 no-access
The 7616TSAssignTable contains entries that provide a means to assign a highway and time slot of that highway to the channel of a loop.
                         uas7616TSAssignEntry 1.3.6.1.4.1.498.12.4.15.1 no-access
An entry in the GDC Circuit Identification table.
                             uas7616TSAssignIndex 1.3.6.1.4.1.498.12.4.15.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable.
                             uas7616ChannelIndex 1.3.6.1.4.1.498.12.4.15.1.2 integer read-write
The index value which uniquely identifies the channel of the interface to which this entry is applicable. Enumeration: 'channelB': 2, 'channelA': 1.
                             uas7616Highway 1.3.6.1.4.1.498.12.4.15.1.3 integer read-write
Defines the highway the channel of the loop is assigned to. Enumeration: 'notAssigned': 1, 'highway2': 3, 'highway1': 2, 'highway4': 5, 'highway3': 4.
                             uas7616TimeSlot 1.3.6.1.4.1.498.12.4.15.1.4 integer read-write
Defines the time slot of the highway the channel of the loop is assigned to. Valid range is 1 to 31. A value of 64 indicates the channel is not assigned to a highway.
                             uas7616TSCircuitID 1.3.6.1.4.1.498.12.4.15.1.5 displaystring read-write
Name to identify the circuit for the channel of this loop.
               uas7616Alarm 1.3.6.1.4.1.498.12.13
                     uas7616AlarmData 1.3.6.1.4.1.498.12.13.1
                         uas7616NoResponseAlm 1.3.6.1.4.1.498.12.13.1.1
                         uas7616DiagRxErrAlm 1.3.6.1.4.1.498.12.13.1.2
                         uas7616PowerUpAlm 1.3.6.1.4.1.498.12.13.1.3
                         uas7616LossOfClockAlm 1.3.6.1.4.1.498.12.13.1.4
                         uas7616LpOutofSyncAlm 1.3.6.1.4.1.498.12.13.1.5
                         uas7616LpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.13.1.6
                         uas7616LpUnavailableSecondAlm 1.3.6.1.4.1.498.12.13.1.7
                         uas7616LpSeverelyErroredSecondAlm 1.3.6.1.4.1.498.12.13.1.8
                         uas7616LpErroredSecondAlm 1.3.6.1.4.1.498.12.13.1.9
                     uas7616AlarmConfigTable 1.3.6.1.4.1.498.12.13.2 no-access
The uas7616AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
                         uas7616AlarmConfigEntry 1.3.6.1.4.1.498.12.13.2.1 no-access
An entry in the GDC Alarm Configuration table.
                             uas7616AlarmConfigIndex 1.3.6.1.4.1.498.12.13.2.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable.
                             uas7616AlarmConfigIdentifier 1.3.6.1.4.1.498.12.13.2.1.2 object identifier read-only
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
                             uas7616AlarmCountWindow 1.3.6.1.4.1.498.12.13.2.1.3 integer read-write
This variable sets/reads the UAS, SES or ES alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Enumeration: 'last1sec': 2, 'last30secs': 4, 'disabled': 1, 'last24hrs': 8, 'last10secs': 3, 'infinite': 9, 'last1hr': 7, 'last15min': 6, 'last1min': 5.
                             uas7616AlarmCountThreshold 1.3.6.1.4.1.498.12.13.2.1.4 integer read-write
This function sets/reads the UAS, SES or ES alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Enumeration: 'occurrence1x': 1, 'occurrence100x': 4, 'occurrence10Kx': 6, 'occurrence1Kx': 5, 'occurrence3x': 2, 'occurrence10x': 3.
               uas7616mAlarm 1.3.6.1.4.1.498.12.14
                     uas7616mAlarmData 1.3.6.1.4.1.498.12.14.1
                         uas7616mNoResponseAlm 1.3.6.1.4.1.498.12.14.1.1
                         uas7616mDiagRxErrAlm 1.3.6.1.4.1.498.12.14.1.2
                         uas7616mPowerUpAlm 1.3.6.1.4.1.498.12.14.1.3
                         uas7616mLossOfClockAlm 1.3.6.1.4.1.498.12.14.1.4
                         uas7616mLpOutofSyncAlm 1.3.6.1.4.1.498.12.14.1.5
                         uas7616mLpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.14.1.6
                         uas7616mLpUnavailableSecondAlm 1.3.6.1.4.1.498.12.14.1.7
                         uas7616mLpErroredSecondAlm 1.3.6.1.4.1.498.12.14.1.8
                         uas7616mLPMajorAlm 1.3.6.1.4.1.498.12.14.1.9
                         uas7616mLPMinorAlm 1.3.6.1.4.1.498.12.14.1.10
                     uas7616mAlarmConfigTable 1.3.6.1.4.1.498.12.14.2 no-access
The uas7616mAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
                         uas7616mAlarmConfigEntry 1.3.6.1.4.1.498.12.14.2.1 no-access
An entry in the GDC Alarm Configuration table.
                             uas7616mAlarmConfigIndex 1.3.6.1.4.1.498.12.14.2.1.1 scinstance read-only
The index value which uniquely identifies the interface to which this entry is applicable.
                             uas7616mAlarmConfigIdentifier 1.3.6.1.4.1.498.12.14.2.1.2 object identifier read-only
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
                             uas7616mAlarmCountThreshold 1.3.6.1.4.1.498.12.14.2.1.3 integer read-write
This function sets/reads the Major or Minor BER alarm threshold criteria. Enumeration: 'thres10E04': 2, 'thres10E05': 3, 'thres10E06': 4, 'thres10E03': 1.