G6-SFP-MIB: View SNMP OID List / Download MIB

VENDOR: MICROSENS


 Home MIB: G6-SFP-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 device 1.3.6.1.4.1.3181.10.6.1
Microsens private MIB for Generation 6 Ethernet Switches
     sfp 1.3.6.1.4.1.3181.10.6.1.34
           configTable 1.3.6.1.4.1.3181.10.6.1.34.1 no-access
These setting apply to each SFP in the system.
               configEntry 1.3.6.1.4.1.3181.10.6.1.34.1.1 no-access
                   configIndex 1.3.6.1.4.1.3181.10.6.1.34.1.1.1 integer no-access
Automatically generated
                   configLossOfSignalEvent 1.3.6.1.4.1.3181.10.6.1.34.1.1.2 integer read-write
When enabled a loss of optical signal or the return of the signal will create an event. Enumeration: 'disabled': 0, 'enabled': 1.
                   configOpticalDeltaDetect 1.3.6.1.4.1.3181.10.6.1.34.1.1.3 integer read-write
An optical receive power level change of more than delta_threshold between two successive read cycles generates an event. Enumeration: 'disabled': 0, 'enabled': 1.
                   configDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.34.1.1.4 integer32 read-write
Defines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recommended value: 2.
           informationTable 1.3.6.1.4.1.3181.10.6.1.34.100 no-access
This table displays data which are read from the inserted SFPs.
                   informationEntry 1.3.6.1.4.1.3181.10.6.1.34.100.1 no-access
                       informationPortIndex 1.3.6.1.4.1.3181.10.6.1.34.100.1.1 integer no-access
Automatically generated
                       informationPort 1.3.6.1.4.1.3181.10.6.1.34.100.1.2 integer read-only
Indicates the physical port in which this SFP is inserted.
                       informationLocation 1.3.6.1.4.1.3181.10.6.1.34.100.1.3 displaystring read-only
Textual description of SFP location.
                       informationStatus 1.3.6.1.4.1.3181.10.6.1.34.100.1.4 bits read-only
Should indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit. Bits: 'laserDisabled': 1, 'lossOfSignal': 2, 'txFailure': 3, 'ok': 0, 'readError': 4.
                       informationType 1.3.6.1.4.1.3181.10.6.1.34.100.1.5 integer read-only
This parameter shows which type of optics are installed Enumeration: 'gbic': 3, 'unknown': 1, 'dwdmSfp': 5, 'sfp': 2, 'dwdmXfp': 10, 'sfpPlus': 11, 'sff': 4, 'xfp': 7, 'csfpA': 8, 'empty': 0, 'csfpB': 9.
                       informationConnector 1.3.6.1.4.1.3181.10.6.1.34.100.1.6 integer read-only
Shows which connector is used with this SFP. Enumeration: 'lc': 1, 'unknown': 0, 'mtRj': 3, 'm': 5, 'rj45': 4, 'sc': 2.
                       informationWavelength 1.3.6.1.4.1.3181.10.6.1.34.100.1.7 displaystring read-only
Nominal wavelength if this SFP. May also indicate ITU channel for DWDM optics.
                       informationTxTechnology 1.3.6.1.4.1.3181.10.6.1.34.100.1.8 displaystring read-only
Distinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown.
                       informationRxTechnology 1.3.6.1.4.1.3181.10.6.1.34.100.1.9 displaystring read-only
Distinguishes between normal PIN receivers and more sensitive APD receivers.
                       informationNominalBitrate 1.3.6.1.4.1.3181.10.6.1.34.100.1.10 displaystring read-only
Nominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well.
                       informationManufacturer 1.3.6.1.4.1.3181.10.6.1.34.100.1.11 displaystring read-only
Shows the manufacturer of this SFP.
                       informationPartNumber 1.3.6.1.4.1.3181.10.6.1.34.100.1.12 displaystring read-only
Shows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer.
                       informationRevision 1.3.6.1.4.1.3181.10.6.1.34.100.1.13 displaystring read-only
Internal revision code of this SFP.
                       informationSerialNumber 1.3.6.1.4.1.3181.10.6.1.34.100.1.14 displaystring read-only
Serial number of the SFP.
                       informationMfgDateCode 1.3.6.1.4.1.3181.10.6.1.34.100.1.15 displaystring read-only
Manufacturing date code.
                       informationWarnings 1.3.6.1.4.1.3181.10.6.1.34.100.1.16 bits read-only
Bits: 'txPowerLow': 0, 'tempLow': 6, 'txPowerHigh': 1, 'txBiasLow': 2, 'tempHigh': 7, 'vccLow': 4, 'txBiasHigh': 3, 'vccHigh': 5, 'rxPowerHigh': 9, 'rxPowerLow': 8.
                       informationAlarms 1.3.6.1.4.1.3181.10.6.1.34.100.1.17 bits read-only
Bits: 'vccTooHigh': 5, 'txPowerTooHigh': 1, 'txBiasTooHigh': 3, 'txBiasTooLow': 2, 'tempTooLow': 6, 'vccTooLow': 4, 'txPowerTooLow': 0, 'rxPowerTooHigh': 9, 'rxPowerTooLow': 8, 'tempTooHigh': 7.
                       informationTxPower 1.3.6.1.4.1.3181.10.6.1.34.100.1.18 displaystring read-only
Indicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
                       informationRxPower 1.3.6.1.4.1.3181.10.6.1.34.100.1.19 displaystring read-only
Indicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
                       informationTemperature 1.3.6.1.4.1.3181.10.6.1.34.100.1.20 displaystring read-only
Displays the temperature inside the SFP. This is usually higher than the system temperature.
                       informationMaxLength9Um 1.3.6.1.4.1.3181.10.6.1.34.100.1.21 displaystring read-only
Displays nominal maximum reach of this SFP on a standard single mode fiber.
                       informationMaxLength50Um 1.3.6.1.4.1.3181.10.6.1.34.100.1.22 displaystring read-only
Displays nominal maximum reach of this SFP on a 50 micro meter multimode fiber.
                       informationMaxLength62Um 1.3.6.1.4.1.3181.10.6.1.34.100.1.23 displaystring read-only
Displays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber.
                       informationMaxLengthCopper 1.3.6.1.4.1.3181.10.6.1.34.100.1.24 displaystring read-only
Displays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP.
                       informationTuningRange 1.3.6.1.4.1.3181.10.6.1.34.100.1.25 displaystring read-only
For wavelength tunable optics additional details are shown here.
                       informationPowerConsumption 1.3.6.1.4.1.3181.10.6.1.34.100.1.26 displaystring read-only
Typcial power consumption values are shown if available from the interface.
                       informationAdditionalInformation 1.3.6.1.4.1.3181.10.6.1.34.100.1.27 displaystring read-only
Some special SFP can supply additional measurement data. For example OTDR reflection data can be listed here.