G6-POE-MIB: View SNMP OID List / Download MIB

VENDOR: MICROSENS


 Home MIB: G6-POE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 device 1.3.6.1.4.1.3181.10.6.1
Microsens private MIB for Generation 6 Ethernet Switches
     poe 1.3.6.1.4.1.3181.10.6.1.33
           poePoeMaxPowerAvailable 1.3.6.1.4.1.3181.10.6.1.33.1 integer32 read-write
Defines the total power that this units power supply can support. This value is used to balance the PoE output power delivered. Please adjust according to connected power supply rating.
           poeRestartPoePort 1.3.6.1.4.1.3181.10.6.1.33.2 displaystring read-write
This function may be used to briefly drop the power on a PoE port in order to reboot the attached device. Please supply port number as parameter. The shorthand port format like 1 for 1/1 may be used. Syntax examples: poe.restart_poe_port = 1/2,1/5 or poe.restart_poe_port = 1-3 or equivalent poe.restart_poe_port = 1/1-1/3.
           configTable 1.3.6.1.4.1.3181.10.6.1.33.3 no-access
Power over Ethernet function permits the powering of connected units which do not use their own local power supply.
               configEntry 1.3.6.1.4.1.3181.10.6.1.33.3.1 no-access
                   configPortIndex 1.3.6.1.4.1.3181.10.6.1.33.3.1.1 integer no-access
Automatically generated
                   configMode 1.3.6.1.4.1.3181.10.6.1.33.3.1.2 integer read-write
Used to enable or disable PoE function. Enumeration: 'forcedOn': 7, 'automatic': 1, 'disabled': 0, 'class4': 6, 'class2': 4, 'class3': 5, 'class0': 2, 'class1': 3.
                   configPriorityPort 1.3.6.1.4.1.3181.10.6.1.33.3.1.3 integer read-write
Ports without priority may be switched off under a power contention situation. Enumeration: 'disabled': 0, 'enabled': 1.
                   configEnablePoePlus 1.3.6.1.4.1.3181.10.6.1.33.3.1.4 integer read-write
Allow between 15-30W power consumption. Enumeration: 'disabled': 0, 'lldpControlled': 2, 'enabled': 1.
           poeTotalPowerConsumed 1.3.6.1.4.1.3181.10.6.1.33.100 unsigned32 read-only
The sum of power currently delivered to all ports. (units: mW)
           statusTable 1.3.6.1.4.1.3181.10.6.1.33.101 no-access
This table list the current PoE port conditions.
                   statusEntry 1.3.6.1.4.1.3181.10.6.1.33.101.1 no-access
                       statusPortIndex 1.3.6.1.4.1.3181.10.6.1.33.101.1.1 integer no-access
Automatically generated
                       statusCondition 1.3.6.1.4.1.3181.10.6.1.33.101.1.2 integer read-only
PoE status and conditions. Enumeration: 'powered': 3, 'overTemp': 8, 'voltageTooLow': 9, 'overCurrent': 7, 'rejected': 6, 'disabled': 0, 'classMismatch': 4, 'powerOff': 1, 'shortCircuit': 5, 'discovering': 2.
                       statusDeterminedClass 1.3.6.1.4.1.3181.10.6.1.33.101.1.3 integer read-only
Determined and negotiated PoE class. Enumeration: 'probesNotEqual': 7, 'isOverload': 5, 'isClass0': 0, 'isClass1': 1, 'isClass2': 2, 'isClass3': 3, 'isClass4': 4, 'isUnknown': 255.
                       statusOutputCurrent 1.3.6.1.4.1.3181.10.6.1.33.101.1.4 integer32 read-only
Current delivered to the attached device. (units: mA)
                       statusOutputVoltage 1.3.6.1.4.1.3181.10.6.1.33.101.1.5 integer32 read-only
Voltage deliverd to the attached device. (units: mV)
                       statusOutputPower 1.3.6.1.4.1.3181.10.6.1.33.101.1.6 integer32 read-only
Calculated power delivered to the attached device. (units: mW)
                       statusPowerDeniedCounter 1.3.6.1.4.1.3181.10.6.1.33.101.1.7 unsigned32 read-only
Incremented whenever a PoE request was denied regardless of reason.
                       statusOverCurrentCounter 1.3.6.1.4.1.3181.10.6.1.33.101.1.8 unsigned32 read-only
Incremented whenever an over_current condition was detected.
                       statusShortCircuitCounter 1.3.6.1.4.1.3181.10.6.1.33.101.1.9 unsigned32 read-only
Incremented whenever a short circuit was detected.
           energySuppliedTable 1.3.6.1.4.1.3181.10.6.1.33.102 no-access
This table list the power provided via PoE ports. The values are automatically updated in the given interval.
                   energySuppliedEntry 1.3.6.1.4.1.3181.10.6.1.33.102.1 no-access
                       energySuppliedPortIndex 1.3.6.1.4.1.3181.10.6.1.33.102.1.1 integer no-access
Automatically generated
                       energySuppliedLast5Seconds 1.3.6.1.4.1.3181.10.6.1.33.102.1.2 unsigned32 read-only
Energy supplied in the past 5 seconds. Value in joule.
                       energySuppliedLast15Seconds 1.3.6.1.4.1.3181.10.6.1.33.102.1.3 unsigned32 read-only
Energy supplied in the past 15 seconds. Value in joule.
                       energySuppliedLastMinute 1.3.6.1.4.1.3181.10.6.1.33.102.1.4 unsigned32 read-only
Energy supplied in the past 60 seconds. Value in joule.
                       energySuppliedLast15Minutes 1.3.6.1.4.1.3181.10.6.1.33.102.1.5 unsigned32 read-only
Energy supplied in the past 15 minutes. Value in joule.
                       energySuppliedLastHour 1.3.6.1.4.1.3181.10.6.1.33.102.1.6 unsigned32 read-only
Energy supplied in the past hour. Value in joule.
                       energySuppliedLastDay 1.3.6.1.4.1.3181.10.6.1.33.102.1.7 unsigned32 read-only
Energy supplied in the past day. Value in joule.