Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 device 1.3.6.1.4.1.3181.10.6.1
Microsens private MIB for Generation 6 Ethernet Switches
     msp1000 1.3.6.1.4.1.3181.10.6.1.94
           systemConfigTable 1.3.6.1.4.1.3181.10.6.1.94.1 no-access
               systemConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.1.1 no-access
                   systemConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.1.1.1 integer no-access
Automatically generated
                   systemConfigNmsOperationMode 1.3.6.1.4.1.3181.10.6.1.94.1.1.2 integer read-write
Read and learn in PASSIVE mode or ACTIVE mode forcing configuration upon the other modules. Enumeration: 'passive': 0, 'active': 1.
                   systemConfigCoreMode 1.3.6.1.4.1.3181.10.6.1.94.1.1.3 integer read-write
Use V2 unless used with an older system running in V1 mode. Only change when instructed. Enumeration: 'v1': 0, 'v2': 1.
                   systemConfigNodeId 1.3.6.1.4.1.3181.10.6.1.94.1.1.4 unsigned32 read-write
Node Id used when NMS is used in combination with SEEmiles V5 management software. When in doubt use default node id 60000.
                   systemConfigDisableLegacyAccess 1.3.6.1.4.1.3181.10.6.1.94.1.1.5 integer read-write
When set network access via SEEmiles is no longer possible. Enumeration: 'disabled': 0, 'enabled': 1.
           slotConfigTable 1.3.6.1.4.1.3181.10.6.1.94.2 no-access
               slotConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.2.1 no-access
                   slotConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.2.1.1 integer no-access
Automatically generated
                   slotConfigModule 1.3.6.1.4.1.3181.10.6.1.94.2.1.2 integer read-write
Defines which module is expected to be placed in this slot. This should be identical to the actual hardware. The value may be set prior to actual roll-out to preconfigure the system. Enumeration: 'nm2': 66, 'nm3': 108, 'nm1': 65, 'txg': 63, 'dc1Filter': 18, 'xcm1': 60, 'om1': 104, 'legacy': 2, 'b4xFilter': 14, 'cxg': 87, 'b8mFilter': 15, 'fc8Filter': 10, 'fc8aFilter': 11, 'fd4Filter': 17, 'lp1': 106, 'passive': 3, 'cxgp': 88, 'em3': 109, 'em2': 105, 'm2g': 56, 'fc8xFilter': 12, 'empty': 1, 'tdm4': 50, 'b8dFilter': 16, 'se1': 19, 'os1': 72, 'wcm2': 57, 't4g': 62, 'undefined': 0, 'nm3p': 110, 'x2g': 61, 'b4sFilter': 13.
                   slotConfigSparepartMode 1.3.6.1.4.1.3181.10.6.1.94.2.1.3 integer read-write
When enabled the module is operating normally but will not generate any alarms. This is useful for modules that are inserted but only used as spare and are not properly connected at this time. This way unnecassary alarms are avoided. Enumeration: 'disabled': 0, 'enabled': 1.
                   slotConfigPort1Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.4 displaystring read-write
User defined port name for easier reference.
                   slotConfigPort2Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.5 displaystring read-write
User defined port name for easier reference.
                   slotConfigPort3Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.6 displaystring read-write
User defined port name for easier reference.
                   slotConfigPort4Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.7 displaystring read-write
User defined port name for easier reference.
           x2gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.3 no-access
This table is used to define any X2G or OFX-3 modules in the system.
               x2gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.3.1 no-access
                   x2gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.3.1.1 integer no-access
Automatically generated
                   x2gConfigPort1Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.2 integer read-write
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. Enumeration: 'sdi': 5, 'oc48': 11, 'ms100mEth': 2, 'oc12': 6, 'otu1': 13, 'hdtv': 9, 'ms1xFc': 7, 'ms2xFc': 10, 'oc3': 3, 'm2g': 12, 'fix100': 1, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   x2gConfigPort2Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.3 integer read-write
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. Enumeration: 'sdi': 5, 'oc48': 11, 'ms100mEth': 2, 'oc12': 6, 'otu1': 13, 'hdtv': 9, 'ms1xFc': 7, 'ms2xFc': 10, 'oc3': 3, 'm2g': 12, 'fix100': 1, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   x2gConfigPort3Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.4 integer read-write
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. Enumeration: 'sdi': 5, 'oc48': 11, 'ms100mEth': 2, 'oc12': 6, 'otu1': 13, 'hdtv': 9, 'ms1xFc': 7, 'ms2xFc': 10, 'oc3': 3, 'm2g': 12, 'fix100': 1, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   x2gConfigPort4Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.5 integer read-write
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. Enumeration: 'sdi': 5, 'oc48': 11, 'ms100mEth': 2, 'oc12': 6, 'otu1': 13, 'hdtv': 9, 'ms1xFc': 7, 'ms2xFc': 10, 'oc3': 3, 'm2g': 12, 'fix100': 1, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   x2gConfigCrossConnect 1.3.6.1.4.1.3181.10.6.1.94.3.1.6 integer read-write
This parameter defines the data path through the module. It is also used to setup a permanent bit error rate test. Enumeration: 'disconnect': 0, 'normal': 20, 'dropContinue': 12, 'alternate': 1, 'ringBackupEast': 15, 'crossOver': 16, 'addDropWest': 13, 'switchP1P4': 19, 'multicast': 11, 'switchP1P3': 18, 'switchP1P2': 17, 'ringBackupWest': 9, 'addDropEast': 14, 'backup': 5, 'bertPort4': 21.
                   x2gConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.3.1.7 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.3.1.8 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.3.1.9 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.3.1.10 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.3.1.11 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
                   x2gConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.3.1.12 integer read-write
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the currently associated port. Enumeration: 'local': 0, 'percolate': 1.
                   x2gConfigOptimizedFor8b10b 1.3.6.1.4.1.3181.10.6.1.94.3.1.13 integer read-write
Enable this feature when Ethernet or FibreChannel is used. Do not set when SDH is used on any port. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.3.1.14 integer read-write
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT. Enumeration: 'cjPat': 4, 'ms8b10bCnt': 6, 'crPat': 5, 'ms27': 0, 'ms223': 2, 'ms231': 3.
                   x2gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.3.1.15 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   x2gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.3.1.16 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
                   x2gConfigBackupTrigger 1.3.6.1.4.1.3181.10.6.1.94.3.1.17 integer read-write
Defines under which optical signal condition an automated backup is initiated. Enumeration: 'disabled': 0, 'clockLoss': 2, 'signalLoss': 1.
                   x2gConfigStayWithLastLink 1.3.6.1.4.1.3181.10.6.1.94.3.1.18 integer read-write
When set the backup switch remains in last position even when signal returns. Still the backup warning turns off after the delay set under backup_end parameter expires. Enumeration: 'disabled': 0, 'enabled': 1.
                   x2gConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.3.1.19 integer read-write
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated. Enumeration: 'ms15Seconds': 1, 'ms15Minutes': 2, 'noDelay': 0, 'manually': 3.
                   x2gConfigPermitLinkOverride 1.3.6.1.4.1.3181.10.6.1.94.3.1.20 integer read-write
Permits the manual selection of a failed link using the link selection. Defaults to false to safeguard against accidential link selection which would result in loss of connection. Enumeration: 'disabled': 0, 'enabled': 1.
           txgConfigTable 1.3.6.1.4.1.3181.10.6.1.94.4 no-access
This table is used to define any TXG or XCM-2 modules in the system.
               txgConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.4.1 no-access
                   txgConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.4.1.1 integer no-access
Automatically generated
                   txgConfigTxgDatarate 1.3.6.1.4.1.3181.10.6.1.94.4.1.2 integer read-write
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. Enumeration: 'otu1f': 7, 'oc192Fec': 3, 'ms10gEth': 2, 'otu2': 4, 'oc192': 1, 'ms10xFc': 5, 'otu2e': 6, 'otu2f': 8.
                   txgConfigTxgOperationMode 1.3.6.1.4.1.3181.10.6.1.94.4.1.3 integer read-write
This parameter defines the data path through the module when an internal cross connect is avalable. It is also used to setup a permanent bit error rate test. (most settings apply to X2G, TXG, OFX-3, XCM-2 only) Enumeration: 'disabled': 0, 'bertPort1': 4, 'bertPort2': 5, 'repeater': 3, 'transponder': 2.
                   txgConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.4.1.4 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   txgConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.4.1.5 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   txgConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.4.1.6 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   txgConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.4.1.7 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   txgConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.4.1.8 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
                   txgConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.4.1.9 integer read-write
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port. Enumeration: 'local': 0, 'percolate': 1.
                   txgConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.4.1.10 integer read-write
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT. Enumeration: 'cjPat': 4, 'ms8b10bCnt': 6, 'crPat': 5, 'ms27': 0, 'ms223': 2, 'ms231': 3.
                   txgConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.4.1.11 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   txgConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.4.1.12 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
           cxgPlusConfigTable 1.3.6.1.4.1.3181.10.6.1.94.5 no-access
This table is used to define any CXG+ or OFC-10 modules in the system.
               cxgPlusConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.5.1 no-access
                   cxgPlusConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.5.1.1 integer no-access
Automatically generated
                   cxgPlusConfigCxgPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.5.1.2 integer read-write
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate. Enumeration: 'ms8xFc': 1, 'transparent': 0, 'ms10xFc16xFc': 3, 'ms10gEth': 2.
                   cxgPlusConfigCxgPort34Datarate 1.3.6.1.4.1.3181.10.6.1.94.5.1.3 integer read-write
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate. Enumeration: 'ms8xFc': 1, 'transparent': 0, 'ms10xFc16xFc': 3, 'ms10gEth': 2.
                   cxgPlusConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.4 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgPlusConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.5 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgPlusConfigPort3ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.6 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgPlusConfigPort4ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.7 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgPlusConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.5.1.8 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgPlusConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.5.1.9 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgPlusConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.5.1.10 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgPlusConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.5.1.11 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgPlusConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.5.1.12 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
                   cxgPlusConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.5.1.13 integer read-write
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port. Enumeration: 'local': 0, 'percolate': 1.
                   cxgPlusConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.5.1.14 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   cxgPlusConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.5.1.15 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
           cxgConfigTable 1.3.6.1.4.1.3181.10.6.1.94.6 no-access
This table is used to define any CXG or XCM-3 modules in the system.
               cxgConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.6.1 no-access
                   cxgConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.6.1.1 integer no-access
Automatically generated
                   cxgConfigCxgPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.6.1.2 integer read-write
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate. Enumeration: 'ms8xFc': 1, 'transparent': 0, 'ms10xFc16xFc': 3, 'ms10gEth': 2.
                   cxgConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.6.1.3 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.6.1.4 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'ch41': 82, 'ch40': 80, 'ch43': 86, 'ch42': 84, 'ch45': 90, 'ch44': 88, 'ch47': 94, 'ch46': 92, 'ch49': 98, 'ch48': 96, 'ch27': 54, 'ch26': 52, 'ch25': 50, 'ch24': 48, 'ch23': 46, 'ch22': 44, 'ch21': 42, 'ch20': 40, 'ch63': 126, 'ch62': 124, 'ch61': 122, 'ch60': 120, 'ch29': 58, 'ch28': 56, 'ch59': 118, 'ch32': 64, 'ch34': 68, 'ch35': 70, 'ch56': 112, 'ch57': 114, 'ch54': 108, 'ch37': 74, 'ch52': 104, 'ch53': 106, 'ch50': 100, 'ch51': 102, 'ch30': 60, 'ch33': 66, 'ch58': 116, 'ch31': 62, 'ch12': 24, 'ch13': 26, 'ch36': 72, 'ch11': 22, 'ch16': 32, 'ch17': 34, 'ch14': 28, 'ch15': 30, 'ch18': 36, 'ch19': 38, 'ch38': 76, 'ch39': 78, 'ch55': 110, 'fixed': 0.
                   cxgConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.6.1.5 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.6.1.6 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   cxgConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.6.1.7 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
                   cxgConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.6.1.8 integer read-write
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port. Enumeration: 'local': 0, 'percolate': 1.
                   cxgConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.6.1.9 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   cxgConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.6.1.10 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
           t4gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.7 no-access
This table is used to define any T4G or OFC-4 modules in the system.
               t4gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.7.1 no-access
                   t4gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.7.1.1 integer no-access
Automatically generated
                   t4gConfigT4gPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.7.1.2 integer read-write
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate. Enumeration: 'oc48': 11, 'infiniband': 12, 'ms100mEth': 2, 'oc12': 6, 'ms1xFc': 7, 'ms2xFc': 10, 'ms4xFc': 14, 'oc3': 3, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   t4gConfigT4gPort34Datarate 1.3.6.1.4.1.3181.10.6.1.94.7.1.3 integer read-write
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received. Enumeration: 'oc48': 11, 'infiniband': 12, 'ms100mEth': 2, 'oc12': 6, 'ms1xFc': 7, 'ms2xFc': 10, 'ms4xFc': 14, 'oc3': 3, 'transparent': 0, 'ms1gEth': 8, 'escon': 4.
                   t4gConfigT4gOperationMode 1.3.6.1.4.1.3181.10.6.1.94.7.1.4 integer read-write
This parameter defines the data path through the module when an internal cross connect is avalable. It is also used to setup a permanent bit error rate test. (most settings apply to X2G, TXG, OFX-3, XCM-2 only) Enumeration: 'disabled': 0, 'transponder': 1, 'bertPort4': 2.
                   t4gConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.7.1.5 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   t4gConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.7.1.6 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   t4gConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.7.1.7 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   t4gConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.7.1.8 integer read-write
When enabled, the optical interface is disabled and communication is cut. Enumeration: 'disabled': 0, 'enabled': 1.
                   t4gConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.7.1.9 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
                   t4gConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.7.1.10 integer read-write
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port. Enumeration: 'local': 0, 'percolate': 1.
                   t4gConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.7.1.11 integer read-write
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT. Enumeration: 'cjPat': 4, 'ms8b10bCnt': 6, 'crPat': 5, 'ms27': 0, 'ms223': 2, 'ms231': 3.
                   t4gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.7.1.12 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   t4gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.7.1.13 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
           m2gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.8 no-access
This table is used to define any M2G or TDM-2 modules in the system.
               m2gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.8.1 no-access
                   m2gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.8.1.1 integer no-access
Automatically generated
                   m2gConfigChannel1Datarate 1.3.6.1.4.1.3181.10.6.1.94.8.1.2 integer read-write
Devices the datarate of the first TDM channel (port 1) Enumeration: 'disabled': 0, 'ms1xFc': 2, 'ms1gEth': 1.
                   m2gConfigChannel2Datarate 1.3.6.1.4.1.3181.10.6.1.94.8.1.3 integer read-write
Devices the datarate of the second TDM channel (port 2) Enumeration: 'disabled': 0, 'ms1xFc': 2, 'ms1gEth': 1.
                   m2gConfigPort1CopperSfp 1.3.6.1.4.1.3181.10.6.1.94.8.1.4 integer read-write
Set when local copper RJ45 SFP is used and connection cannot be established. Enumeration: 'disabled': 0, 'enabled': 1.
                   m2gConfigPort2CopperSfp 1.3.6.1.4.1.3181.10.6.1.94.8.1.5 integer read-write
Set when local copper RJ45 SFP is used and connection cannot be established. Enumeration: 'disabled': 0, 'enabled': 1.
                   m2gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.8.1.6 integer read-write
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value. Enumeration: 'ms240Sec': 6, 'ms60Sec': 5, 'disabled': 0, 'ms10Sec': 3, 'ms5Sec': 2, 'ms1Sec': 1, 'ms30Sec': 4.
                   m2gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.8.1.7 integer read-write
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. Enumeration: 'ms05Db': 0, 'ms2Db': 3, 'ms1Db': 1, 'ms15Db': 2, 'ms5Db': 5, 'ms3Db': 4.
                   m2gConfigLinkBackupTrigger 1.3.6.1.4.1.3181.10.6.1.94.8.1.8 integer read-write
Defines under which optical signal condition an automated backup is initiated. Enumeration: 'disabled': 0, 'signalLoss': 1, 'errorBurst': 2.
                   m2gConfigStayWithLastLink 1.3.6.1.4.1.3181.10.6.1.94.8.1.9 integer read-write
When set the backup switch remains in last position even when signal returns. Still the backup warning turns off after the delay set under backup_end parameter expires. Enumeration: 'disabled': 0, 'enabled': 1.
                   m2gConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.8.1.10 integer read-write
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated. Enumeration: 'ms15Seconds': 1, 'ms15Minutes': 2, 'noDelay': 0, 'manually': 3.
                   m2gConfigPermitLinkOverride 1.3.6.1.4.1.3181.10.6.1.94.8.1.11 integer read-write
Permits the manual selection of a failed link using the link selection. Defaults to false to safeguard against accidential link selection which would result in loss of connection. Enumeration: 'disabled': 0, 'enabled': 1.
           om1ConfigTable 1.3.6.1.4.1.3181.10.6.1.94.9 no-access
               om1ConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.9.1 no-access
                   om1ConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.9.1.1 integer no-access
Automatically generated
                   om1ConfigWavelengthPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.2 integer read-write
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured. Enumeration: 'disabled': 3, 'ms1550nm': 0, 'ms1310nm': 1.
                   om1ConfigLowThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.3 displaystring read-write
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
                   om1ConfigHighThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.4 displaystring read-write
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
                   om1ConfigWavelengthPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.5 integer read-write
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured. Enumeration: 'disabled': 3, 'ms1550nm': 0, 'ms1310nm': 1.
                   om1ConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.6 displaystring read-write
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
                   om1ConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.7 displaystring read-write
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
                   om1ConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.9.1.8 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
           lp1ConfigTable 1.3.6.1.4.1.3181.10.6.1.94.10 no-access
                 lp1ConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.10.1 no-access
                     lp1ConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.10.1.1 integer no-access
Automatically generated
                     lp1ConfigWavelengthPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.2 integer read-write
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured. Enumeration: 'disabled': 3, 'ms1550nm': 0, 'ms1310nm': 1.
                     lp1ConfigLowThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.3 displaystring read-write
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event and a backup when configured.
                     lp1ConfigHighThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.4 displaystring read-write
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event and a backup when configured.
                     lp1ConfigWavelengthPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.5 integer read-write
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured. Enumeration: 'disabled': 3, 'ms1550nm': 0, 'ms1310nm': 1.
                     lp1ConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.6 displaystring read-write
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event and a backup when configured.
                     lp1ConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.7 displaystring read-write
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event and a backup when configured.
                     lp1ConfigBackupCriteria 1.3.6.1.4.1.3181.10.6.1.94.10.1.8 integer read-write
Defines under which optical signal condition an automated backup is initiated. Enumeration: 'signalHigh': 1, 'signalLow': 0, 'manually': 2.
                     lp1ConfigStayWithLastLink 1.3.6.1.4.1.3181.10.6.1.94.10.1.9 integer read-write
When set the backup switch remains in last position even when signal return. Still the backup warning turns off after the delay set under backup_end parameter expires. Enumeration: 'disabled': 0, 'enabled': 1.
                     lp1ConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.10.1.10 integer read-write
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated. Enumeration: 'ms15Seconds': 1, 'ms15Minutes': 2, 'noDelay': 0, 'manually': 3.
                     lp1ConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.10.1.11 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
           emConfigTable 1.3.6.1.4.1.3181.10.6.1.94.11 no-access
Configuration for EDFA amplifier modules EM2 and EM3.
                 emConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.11.1 no-access
                     emConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.11.1.1 integer no-access
Automatically generated
                     emConfigEdfaOperationMode 1.3.6.1.4.1.3181.10.6.1.94.11.1.2 integer read-write
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured. Enumeration: 'preAmp': 0, 'pumpDisabled': 3, 'booster': 1.
                     emConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.11.1.3 integer read-write
Defines if loss of input signal turns off the EDFA pump (PERCOLATE) or not (LOCAL) Enumeration: 'local': 0, 'percolate': 1.
                     emConfigSignalGain 1.3.6.1.4.1.3181.10.6.1.94.11.1.4 displaystring read-write
Desired signal gain in dB.
                     emConfigMaxOutputPower 1.3.6.1.4.1.3181.10.6.1.94.11.1.5 displaystring read-write
Maximum output power permitted to exit the module.
                     emConfigLowThresholdEdfaIn 1.3.6.1.4.1.3181.10.6.1.94.11.1.6 displaystring read-write
This corresponds to the unamplified input signal before entering the EDFA section. Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
                     emConfigHighThresholdEdfaIn 1.3.6.1.4.1.3181.10.6.1.94.11.1.7 displaystring read-write
This corresponds to the unamplified input signal before entering the EDFA section. Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
                     emConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.11.1.8 displaystring read-write
Port B is the unamplified return path through the module. Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
                     emConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.11.1.9 displaystring read-write
Port B is the unamplified return path through the module. Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
                     emConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.11.1.10 integer read-write
Determines what is displayed on the front panel, when available. Also controls the modules local buttons. Enumeration: 'extendedLocked': 5, 'extended': 1, 'remote': 7, 'normalLocked': 4, 'normal': 0.
           moduleControlTable 1.3.6.1.4.1.3181.10.6.1.94.12 no-access
                 moduleControlEntry 1.3.6.1.4.1.3181.10.6.1.94.12.1 no-access
                     moduleControlIndex 1.3.6.1.4.1.3181.10.6.1.94.12.1.1 integer no-access
Automatically generated
                     moduleControlEnterPassword 1.3.6.1.4.1.3181.10.6.1.94.12.1.2 displaystring read-write
This command will set the module password. Only required when the nms_operation_mode is set to passive mode. Enter the password before configuration or actions can be accepted by the module.
                     moduleControlRebootModule 1.3.6.1.4.1.3181.10.6.1.94.12.1.3 displaystring read-write
This command will restart the module. All communication will be disrupted! Syntax: reboot_module = CONFIRM.
                     moduleControlWarmStart 1.3.6.1.4.1.3181.10.6.1.94.12.1.4 displaystring read-write
This command will warm start the module. Communication shall not be disrupted. (Firmware dependend) Syntax: warm_start = CONFIRM.
                     moduleControlClearCounter 1.3.6.1.4.1.3181.10.6.1.94.12.1.5 displaystring read-write
This command will clear all module and port related statistics counter.
                     moduleControlSwitchOffBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.6 displaystring read-write
For a module that supports backup and which currently is in backup condition this command will revert to normal operation. If this would disrupt traffic a warning is returned and nothing is executed. To override this warning and switch back nonetheless type switch_off_backup = CONFIRM
                     moduleControlSwitchToBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.7 displaystring read-write
For a module that supports backup this command will switch to the backup link. If this would disrupt traffic because backup link is not available a warning is returned and nothing is executed. To override this warning and switch over nonetheless type switch_to_backup = CONFIRM
                     moduleControlAutomaticBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.8 displaystring read-write
This command returns a manually overridden backup module to normal automatic mode. No parameter are required.
                     moduleControlWriteDisplay 1.3.6.1.4.1.3181.10.6.1.94.12.1.9 displaystring read-write
Writes to the front panel display of the module. Only for modules that offer a front panel display.
                     moduleControlLedTest 1.3.6.1.4.1.3181.10.6.1.94.12.1.10 displaystring read-write
This will start the modules LED test and will return the LED back up automatic mode after a few seconds. May be also be used to identify a certain module.
                     moduleControlLoopOff 1.3.6.1.4.1.3181.10.6.1.94.12.1.11 displaystring read-write
Turns all loops off
                     moduleControlLoopPort1 1.3.6.1.4.1.3181.10.6.1.94.12.1.12 displaystring read-write
Tries to engage a loop at port 1. Note not all modules support loops. View port status to check success.
                     moduleControlLoopPort2 1.3.6.1.4.1.3181.10.6.1.94.12.1.13 displaystring read-write
Tries to engage a loop at port 2. Note not all modules support loops. View port status to check success.
                     moduleControlLoopPort3 1.3.6.1.4.1.3181.10.6.1.94.12.1.14 displaystring read-write
Tries to engage a loop at port 3. Note not all modules support loops. View port status to check success.
                     moduleControlLoopPort4 1.3.6.1.4.1.3181.10.6.1.94.12.1.15 displaystring read-write
Tries to engage a loop at port 4. Note not all modules support loops. View port status to check success.
                     moduleControlBertRestart 1.3.6.1.4.1.3181.10.6.1.94.12.1.16 displaystring read-write
Resynchronizes BERT. Only has an effect if a BERT is available on the module and configured to be active.
                     moduleControlBertInsertError 1.3.6.1.4.1.3181.10.6.1.94.12.1.17 displaystring read-write
Inserts an error in the data pattern. This can be used to confirm that a BERT is actually operating. Only has an effect if a BERT is available on the module and configured to be active.
                     moduleControlBertClearCounter 1.3.6.1.4.1.3181.10.6.1.94.12.1.18 displaystring read-write
Clears the BERT counter. Only has an effect if a BERT is available on the module and configured to be active.
           systemStatusTable 1.3.6.1.4.1.3181.10.6.1.94.100 no-access
                   systemStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.100.1 no-access
                       systemStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.100.1.1 integer no-access
Automatically generated
                       systemStatusAnyErrorCondition 1.3.6.1.4.1.3181.10.6.1.94.100.1.2 integer read-only
True when any error condition is currently present in any module. Enumeration: 'true': 1, 'false': 0.
                       systemStatusAnyTestMode 1.3.6.1.4.1.3181.10.6.1.94.100.1.3 integer read-only
True when any module is in loopback test or has a backup engaged. Enumeration: 'true': 1, 'false': 0.
                       systemStatusAnySparePart 1.3.6.1.4.1.3181.10.6.1.94.100.1.4 integer read-only
True when any module is marked as spare part. Enumeration: 'true': 1, 'false': 0.
                       systemStatusUsedNodeId 1.3.6.1.4.1.3181.10.6.1.94.100.1.5 unsigned32 read-only
Actually used node id as discovered from device
                       systemStatusLocalRack 1.3.6.1.4.1.3181.10.6.1.94.100.1.6 unsigned32 read-only
Indicates in which rack the mangement module over which this information is retrieved is inserted.
                       systemStatusLocalSlot 1.3.6.1.4.1.3181.10.6.1.94.100.1.7 unsigned32 read-only
Indicates in which slot the mangement module over which this information is retrieved is inserted.
           moduleInventoryTable 1.3.6.1.4.1.3181.10.6.1.94.101 no-access
                   moduleInventoryEntry 1.3.6.1.4.1.3181.10.6.1.94.101.1 no-access
                       moduleInventoryIndex 1.3.6.1.4.1.3181.10.6.1.94.101.1.1 integer no-access
Automatically generated
                       moduleInventoryExpectedModule 1.3.6.1.4.1.3181.10.6.1.94.101.1.2 displaystring read-only
Name of module configured for this slot.
                       moduleInventoryModule 1.3.6.1.4.1.3181.10.6.1.94.101.1.3 displaystring read-only
Name of module actually discovered in this slot. This name should be equal to the above name otherwise configuration may not apply properly.
                       moduleInventoryType 1.3.6.1.4.1.3181.10.6.1.94.101.1.4 integer read-only
General functional type of module inserted. Enumeration: 'management': 5, 'unknown': 1, 'amplifier': 4, 'transponder': 2, 'passive': 6, 'measurement': 3, 'occupied': 7, 'empty': 0.
                       moduleInventoryBoardCode 1.3.6.1.4.1.3181.10.6.1.94.101.1.5 integer32 read-only
Internal code of actually inserted module.
                       moduleInventoryAdditionalInfo 1.3.6.1.4.1.3181.10.6.1.94.101.1.6 displaystring read-only
Additional information that may be saved in some modules during production.
                       moduleInventorySerialNumber 1.3.6.1.4.1.3181.10.6.1.94.101.1.7 displaystring read-only
Serial number as stored within the hardware.
                       moduleInventoryOccupiedSlots 1.3.6.1.4.1.3181.10.6.1.94.101.1.8 unsigned32 read-only
Number of slots taken by this module. Usually 1.
                       moduleInventoryProjectNumber 1.3.6.1.4.1.3181.10.6.1.94.101.1.9 displaystring read-only
Internal hardware project number
                       moduleInventoryBuildVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.10 displaystring read-only
Precise build code for hardware version tracking.
                       moduleInventoryProductionDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.11 displaystring read-only
Production data of the module
                       moduleInventoryMfgTestInfo 1.3.6.1.4.1.3181.10.6.1.94.101.1.12 displaystring read-only
Internal information for quality management. Manufacturing Site / Test Site / Test Person
                       moduleInventoryNumberOfOpticalPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.13 integer32 read-only
Indicates the number of actively monitored optical ports of this type of module.
                       moduleInventoryNumberOfSfpPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.14 integer32 read-only
Indicates the number of optical SFP or SFP+ ports of this type of module.
                       moduleInventoryNumberOfXfpPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.15 integer32 read-only
Indicates the number of optical XFP ports of this type of module.
                       moduleInventoryCoreFirmwareVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.16 displaystring read-only
Core operating system software version.
                       moduleInventoryCoreFirmwareDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.17 displaystring read-only
Core operating system software creation date.
                       moduleInventoryApplFirmwareVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.18 displaystring read-only
Application software version.
                       moduleInventoryApplFirmwareDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.19 displaystring read-only
Application software creation date.
           moduleStatusTable 1.3.6.1.4.1.3181.10.6.1.94.102 no-access
This table holds a record for each module in the system. Note that not all modules deliver every kind of status.
                   moduleStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.102.1 no-access
                       moduleStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.102.1.1 integer no-access
Automatically generated
                       moduleStatusModule 1.3.6.1.4.1.3181.10.6.1.94.102.1.2 displaystring read-only
Name of module actually discovered in this slot.
                       moduleStatusSystemOk 1.3.6.1.4.1.3181.10.6.1.94.102.1.3 integer read-only
True when the module has booted and appears ok. Enumeration: 'true': 1, 'false': 0.
                       moduleStatusErrorCondition 1.3.6.1.4.1.3181.10.6.1.94.102.1.4 integer read-only
True when any error condition is currently present. Enumeration: 'true': 1, 'false': 0.
                       moduleStatusTestMode 1.3.6.1.4.1.3181.10.6.1.94.102.1.5 integer read-only
True when module is in loopback test or a backup is engaged. Enumeration: 'true': 1, 'false': 0.
                       moduleStatusSparePart 1.3.6.1.4.1.3181.10.6.1.94.102.1.6 integer read-only
True when module is marked as spare part. Enumeration: 'true': 1, 'false': 0.
                       moduleStatusUptime 1.3.6.1.4.1.3181.10.6.1.94.102.1.7 counter32 read-only
Uptime since last reboot in seconds.
                       moduleStatusTimeSinceCounterReset 1.3.6.1.4.1.3181.10.6.1.94.102.1.8 counter32 read-only
How long ago have the statistics counter been restarted.
                       moduleStatusTemperature 1.3.6.1.4.1.3181.10.6.1.94.102.1.9 integer32 read-only
Temperature value in centigrade.
                       moduleStatusTooHot 1.3.6.1.4.1.3181.10.6.1.94.102.1.10 integer read-only
True when module is running too hot. Enumeration: 'true': 1, 'false': 0.
                       moduleStatusBackupState 1.3.6.1.4.1.3181.10.6.1.94.102.1.11 bits read-only
Indicates if a backup is active and in which state. Bits: 'disrupted': 0, 'backup': 1, 'awaitSwitchback': 2, 'manual': 3.
                       moduleStatusBackupCounter 1.3.6.1.4.1.3181.10.6.1.94.102.1.12 unsigned32 read-only
Counts the number of times this module has initiated a backup (if backup feature is available for this module type).
                       moduleStatusBackupDuration 1.3.6.1.4.1.3181.10.6.1.94.102.1.13 counter32 read-only
How long the backup has been activated in total since last value reset.
           portStatusTable 1.3.6.1.4.1.3181.10.6.1.94.103 no-access
This table holds a record for each optical port of the system. Note that not all modules deliver every kind of statistic.
                   portStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.103.1 no-access
                       portStatusPortIndex 1.3.6.1.4.1.3181.10.6.1.94.103.1.1 integer no-access
Automatically generated
                       portStatusModule 1.3.6.1.4.1.3181.10.6.1.94.103.1.2 displaystring read-only
Name of module in which this port is present.
                       portStatusLocation 1.3.6.1.4.1.3181.10.6.1.94.103.1.3 displaystring read-only
Textual description of port location.
                       portStatusSnmpPort 1.3.6.1.4.1.3181.10.6.1.94.103.1.4 unsigned32 read-only
Slot and port representation as used in SNMP. Formula is Slot*10000 + Port*10.
                       portStatusAlias 1.3.6.1.4.1.3181.10.6.1.94.103.1.5 displaystring read-only
Configured alias nickname of this port.
                       portStatusAdminStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.6 integer read-only
Reflects the administrative setting of this port. Enumeration: 'down': 2, 'none': 0, 'testing': 3, 'up': 1.
                       portStatusOperStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.7 integer read-only
Indicates the combined operation port status. Enumeration: 'down': 2, 'none': 0, 'testing': 3, 'up': 1.
                       portStatusDetailedStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.8 bits read-only
Indicates detailed issues related to the port. Bits: 'pllNotLocked': 2, 'none': 9, 'reserved': 7, 'laserOff': 5, 'tooHigh': 4, 'sfpMissing': 1, 'disabled': 0, 'unknown': 8, 'signalLow': 3, 'loop': 6.
                       portStatusPortDatarate 1.3.6.1.4.1.3181.10.6.1.94.103.1.9 integer read-only
Reflects the data rate setting of this port. Enumeration: 'oc12': 21, 'ms10xFc': 14, 'ms2xFc': 11, 'otu2e': 34, 'otu2f': 35, 'txp': 1, 'otu1e': 31, 'otu1f': 32, 'ms100mEth': 2, 'otu2': 33, 'oc192': 23, 'ms16xFc': 15, 'other': 45, 'tdm2': 44, 'fix100': 40, 'oc48': 22, 'ms8xFc': 13, 'hdtv': 43, 'ms1xFc': 10, 'ms10gEth': 4, 'sdi': 42, 'none': 0, 'otu1': 30, 'escon': 41, 'ms4xFc': 12, 'oc3': 20, 'ms1gEth': 3.
                       portStatusUpdateTimeStamp 1.3.6.1.4.1.3181.10.6.1.94.103.1.10 displaystring read-only
Indicates the time when this record was last updated.
                       portStatusTimeSinceValueReset 1.3.6.1.4.1.3181.10.6.1.94.103.1.11 counter32 read-only
Time since when the following statistics have been accumulated. They restart upon module power up or on forced value reset.
                       portStatusTimeSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.103.1.12 counter32 read-only
Time since last input signal loss or input signal too high.
                       portStatusTimeSignalTooLow 1.3.6.1.4.1.3181.10.6.1.94.103.1.13 counter32 read-only
Total time the input signal was below threshold.
                       portStatusSignalTooLowCounter 1.3.6.1.4.1.3181.10.6.1.94.103.1.14 unsigned32 read-only
Number of times a transition to signal too low has occured.
                       portStatusTimeSignalTooHigh 1.3.6.1.4.1.3181.10.6.1.94.103.1.15 counter32 read-only
Total time the input signal was above high threshold.
                       portStatusSignalTooHighCounter 1.3.6.1.4.1.3181.10.6.1.94.103.1.16 unsigned32 read-only
Number of times a transition to signal too high has occured.
                       portStatusLowThreshold 1.3.6.1.4.1.3181.10.6.1.94.103.1.17 displaystring read-only
Defined signal too low threshold.
                       portStatusCurrentInputSignal 1.3.6.1.4.1.3181.10.6.1.94.103.1.18 displaystring read-only
Actual current signal level.
                       portStatusHighThreshold 1.3.6.1.4.1.3181.10.6.1.94.103.1.19 displaystring read-only
Defined signal too high threshold.
           emStatusTable 1.3.6.1.4.1.3181.10.6.1.94.104 no-access
Optical amplifier status
                   emStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.104.1 no-access
                       emStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.104.1.1 integer no-access
Automatically generated
                       emStatusSystemOk 1.3.6.1.4.1.3181.10.6.1.94.104.1.2 integer read-only
True when no errors are present Enumeration: 'true': 1, 'false': 0.
                       emStatusErrors 1.3.6.1.4.1.3181.10.6.1.94.104.1.3 bits read-only
Indicates various optical error conditions. Bits: 'tooHot': 2, 'powerLimit': 5, 'backReflection': 4, 'pumpDown': 7, 'lossOfInput': 0, 'lossOfOutput': 1, 'overCurrent': 6, 'eyeSafetyShutdown': 3.
                       emStatusHardwareCode 1.3.6.1.4.1.3181.10.6.1.94.104.1.4 displaystring read-only
Details codes about the installed hardware components.
                       emStatusTimeSincePowerError 1.3.6.1.4.1.3181.10.6.1.94.104.1.5 counter32 read-only
How long ago since the last time the output power was in error condition.
                       emStatusTimeWithPowerLoss 1.3.6.1.4.1.3181.10.6.1.94.104.1.6 counter32 read-only
Accumulated time the output power has been down.
                       emStatusInputSignalLowCounter 1.3.6.1.4.1.3181.10.6.1.94.104.1.7 unsigned32 read-only
Number of times a loss of signal has occured.
                       emStatusInputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.8 displaystring read-only
Optical input power of port A.
                       emStatusSignalGain 1.3.6.1.4.1.3181.10.6.1.94.104.1.9 displaystring read-only
Indicates how strong the input signal is amplified.
                       emStatusOptimalFlatGain 1.3.6.1.4.1.3181.10.6.1.94.104.1.10 displaystring read-only
Indicates the best gain setting for an even amplification accross the wavelength channels
                       emStatusBackReflection 1.3.6.1.4.1.3181.10.6.1.94.104.1.11 displaystring read-only
The value should be low and indicates cable issues if not.
                       emStatusSignalOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.12 displaystring read-only
Indicated the actually achieved optical signal output power.
                       emStatusTotalOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.13 displaystring read-only
Indicated the actually achieved optical output power leaving the module (including noise).
                       emStatusMinOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.14 displaystring read-only
Indicates the minimum optical output level that must be send out
                       emStatusMaxOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.15 displaystring read-only
Indicates the maximum optical output level that can be send out
                       emStatusCfgOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.16 displaystring read-only
Indicated the desired configured optical output power
           bertStatusTable 1.3.6.1.4.1.3181.10.6.1.94.105 no-access
Displays the results of the bit error rate tester (BERT) if it is present and enabled in a slot
                   bertStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.105.1 no-access
                       bertStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.105.1.1 integer no-access
Automatically generated
                       bertStatusLocation 1.3.6.1.4.1.3181.10.6.1.94.105.1.2 displaystring read-only
Textual description of BERT port location.
                       bertStatusBertOperation 1.3.6.1.4.1.3181.10.6.1.94.105.1.3 integer read-only
Indicates the general bit error rate tester operational status. Enumeration: 'unused': 0, 'outOfSync': 3, 'inSync': 1, 'wasOutOfSync': 2.
                       bertStatusTotalErrors 1.3.6.1.4.1.3181.10.6.1.94.105.1.4 unsigned32 read-only
Number of errored bits. Only valid when BERT is synchronized.
                       bertStatusTimeSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.105.1.5 counter32 read-only
Seconds elapsed since the last error was detected.
                       bertStatusTotalTestTime 1.3.6.1.4.1.3181.10.6.1.94.105.1.6 counter32 read-only
Accumulated time how long the test was run since last value clear.
                       bertStatusErroredTime 1.3.6.1.4.1.3181.10.6.1.94.105.1.7 counter32 read-only
Accumulated seconds in which at least on errored bit was detected.
                       bertStatusBitErrorRate 1.3.6.1.4.1.3181.10.6.1.94.105.1.8 displaystring read-only
Averaged bit error rate during test interval.
                       bertStatusBerSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.105.1.9 displaystring read-only
Bit error rate since last error.
                       bertStatusTheoreticalBer 1.3.6.1.4.1.3181.10.6.1.94.105.1.10 displaystring read-only
Theoretical best possible error rate in the given time frame of the current test interval.
                       bertStatusAvailability 1.3.6.1.4.1.3181.10.6.1.94.105.1.11 displaystring read-only
Relation of transmitted vs. Errored bits.