Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
               finMIBCompliance 1.3.6.1.2.1.43.2.3
The compliance statement for agents that implement the finisher MIB.
               finMIBGroups 1.3.6.1.2.1.43.2.4
                   finDeviceGroup 1.3.6.1.2.1.43.2.4.1
The finisher device group.
                   finSupplyGroup 1.3.6.1.2.1.43.2.4.2
The finisher supply group.
                   finSupplyMediaInputGroup 1.3.6.1.2.1.43.2.4.3
The finisher supply, media input group.
                   finDeviceAttributeGroup 1.3.6.1.2.1.43.2.4.4
The finisher device attribute group.
           finDevice 1.3.6.1.2.1.43.30
                 finDeviceTable 1.3.6.1.2.1.43.30.1 no-access
This table defines the finishing device subunits, including information regarding possible configuration options and the status for each finisher device subunit.
                     finDeviceEntry 1.3.6.1.2.1.43.30.1.1 no-access
There is an entry in the finishing device table for each possible finisher process.
                         finDeviceIndex 1.3.6.1.2.1.43.30.1.1.1 integer32 no-access
A unique value used to identify a finisher process. Although these values may change due to a major reconfiguration of the printer system (e.g. the addition of new finishing processes), the values are normally expected to remain stable across successive power cycles.
                         finDeviceType 1.3.6.1.2.1.43.30.1.1.2 findevicetypetc read-only
Defines the type of finishing process associated with this table row entry.
                         finDevicePresentOnOff 1.3.6.1.2.1.43.30.1.1.3 presentonoff read-write
Indicates if this finishing device subunit is available and whether the device subunit is enabled.
                         finDeviceCapacityUnit 1.3.6.1.2.1.43.30.1.1.4 prtcapacityunittc read-only
The unit of measure for specifying the capacity of this finisher device subunit.
                         finDeviceMaxCapacity 1.3.6.1.2.1.43.30.1.1.5 integer32 read-write
The maximum capacity of this finisher device subunit in finDeviceCapacityUnits. If the device can reliably sense this value, the value is sensed by the finisher device and is read-only: otherwise the value may be written by a management or control console application. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means unknown.
                         finDeviceCurrentCapacity 1.3.6.1.2.1.43.30.1.1.6 integer32 read-write
The current capacity of this finisher device subunit in finDeviceCapacityUnits. If the device can reliably sense this value, the value is sensed by the finisher and is read-only: otherwise the value may be written by a management or control console application. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means unknown.
                         finDeviceAssociatedMediaPaths 1.3.6.1.2.1.43.30.1.1.7 octet string read-only
Indicates the media paths which can supply media for this finisher device. The value of this object is a bit map in an octet string with each position representing the value of a prtMediaPathIndex. For a media path that can be a source for this finisher device subunit, the bit position equal to one less than the value of prtMediaPathIndex will be set. The bits are numbered starting with the most significant bit of the first byte being bit 0, the least significant bit of the first byte being bit 7, the most significant of the second byte being bit 8, and so on.
                         finDeviceAssociatedOutputs 1.3.6.1.2.1.43.30.1.1.8 octet string read-only
Indicates the printer output subunits this finisher device subunit services. The value of this object is a bit map in an octet string with each position representing the value of a prtOutputIndex. For an output subunit that is serviced by this finisher device subunit, the bit position equal to to one less than the value of prtOutputIndex will be set. The bits are numbered starting with the most significant bit of the first byte being bit 0, the least significant bit of the first byte being bit 7, the most significant of the second byte being bit 8, and so on.
                         finDeviceStatus 1.3.6.1.2.1.43.30.1.1.9 prtsubunitstatustc read-only
Indicates the current status of this finisher device subunit.
                         finDeviceDescription 1.3.6.1.2.1.43.30.1.1.10 octet string read-only
A free form text description of this device subunit in the localization specified by prtGeneralCurrentLocalization.
           finSupply 1.3.6.1.2.1.43.31
                 finSupplyTable 1.3.6.1.2.1.43.31.1 no-access
Each unique source of supply is an entry in the finisher supply table. Each supply entry has its own characteristics associated with it such as colorant and current supply level.
                     finSupplyEntry 1.3.6.1.2.1.43.31.1.1 no-access
A list of finisher devices, with their associated supplies and supplies characteristics.
                         finSupplyIndex 1.3.6.1.2.1.43.31.1.1.1 integer32 no-access
A unique value used by a finisher to identify this supply container/receptacle. Although these values may change due to a major reconfiguration of the finisher (e.g. the addition of new supply sources to the finisher), values are normally expected to remain stable across successive power cycles.
                         finSupplyDeviceIndex 1.3.6.1.2.1.43.31.1.1.2 integer32 read-only
The value of finDeviceIndex corresponding to the finishing device subunit with which this finisher supply is associated.
                         finSupplyClass 1.3.6.1.2.1.43.31.1.1.3 prtmarkersuppliesclasstc read-only
This value indicates whether this supply entity represents a supply that is consumed or a container that is filled.
                         finSupplyType 1.3.6.1.2.1.43.31.1.1.4 prtmarkersuppliestypetc read-only
The type of this supply.
                         finSupplyDescription 1.3.6.1.2.1.43.31.1.1.5 octet string read-only
The description of this supply/receptacle in text useful for operators and management applications and in the localization specified by prtGeneralCurrentLocalization.
                         finSupplyUnit 1.3.6.1.2.1.43.31.1.1.6 prtmarkersuppliessupplyunittc read-only
Unit of measure of this finisher supply container or receptacle.
                         finSupplyMaxCapacity 1.3.6.1.2.1.43.31.1.1.7 integer32 read-write
The maximum capacity of this supply container/receptacle expressed in Supply Units. If this supply container/ receptacle can reliably sense this value, the value is sensed and is read-only; otherwise the value may be written by a control panel or management application. The value (-1) means other and places no restrictions on this parameter. The value (-2) means unknown.
                         finSupplyCurrentLevel 1.3.6.1.2.1.43.31.1.1.8 integer32 read-write
The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed and is read-only; otherwise the value may be written by a control panel or management application. The value (-1) means other and places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows there is some supply or remaining space.
                         finSupplyColorName 1.3.6.1.2.1.43.31.1.1.9 octet string read-only
The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other, unknown, white, red, green, blue, cyan, magenta, yellow and black. Implementors may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes.
           finSupplyMediaInput 1.3.6.1.2.1.43.32
                 finSupplyMediaInputTable 1.3.6.1.2.1.43.32.1 no-access
The input subunits associated with a finisher supply media are each represented by an entry in this table.
                     finSupplyMediaInputEntry 1.3.6.1.2.1.43.32.1.1 no-access
A list of finisher supply media input subunit features and characteristics.
                         finSupplyMediaInputIndex 1.3.6.1.2.1.43.32.1.1.1 integer32 no-access
A unique value used by a finisher to identify this supply media input subunit. Although these values may change due to a major reconfiguration of the finisher (e.g. the addition of new supply media input sources to the finisher), values are normally expected to remain stable across successive power cycles.
                         finSupplyMediaInputDeviceIndex 1.3.6.1.2.1.43.32.1.1.2 integer32 read-only
The value of finDeviceIndex corresponding to the finishing device subunit with which this finisher media supply is associated.
                         finSupplyMediaInputSupplyIndex 1.3.6.1.2.1.43.32.1.1.3 integer32 read-only
The value of finSupplyIndex corresponding to the finishing supply subunit with which this finisher media supply is associated.
                         finSupplyMediaInputType 1.3.6.1.2.1.43.32.1.1.4 prtinputtypetc read-only
The type of technology (discriminated primarily according to the feeder mechanism type) employed by the input subunit.
                         finSupplyMediaInputDimUnit 1.3.6.1.2.1.43.32.1.1.5 prtmediaunittc read-only
The unit of measure for specifying dimensional values for this input device.
                         finSupplyMediaInputMediaDimFeedDir 1.3.6.1.2.1.43.32.1.1.6 integer32 read-write
This object provides the value of the dimension in the feed direction of the media that is placed or will be placed in this input device. Feed dimension measurements are taken parallel to the feed direction of the device and measured in finSupplyMediaInputDimUnits. If this input device can reliably sense this value, the value is sensed and is read-only access. Otherwise the value is read-write access and may be written by management or control panel applications. The value (-1) means other and specifically indicates that this device places no restrictions on this parameter. The value (-2) indicates unknown.
                         finSupplyMediaInputMediaDimXFeedDir 1.3.6.1.2.1.43.32.1.1.7 integer32 read-write
This object provides the value of the dimension across the feed direction of the media that is placed or will be placed in this input device. The cross feed direction is ninety degrees relative to the feed direction on this device and measured in finSupplyMediaInputDimUnits. If this input device can reliably sense this value, the value is sensed and is read-only access. Otherwise the value is read-write access and may be written by management or control panel applications. The value (-1) means other and specifically indicates that this device places no restrictions on this parameter. The value (-2) indicates unknown.
                         finSupplyMediaInputStatus 1.3.6.1.2.1.43.32.1.1.8 prtsubunitstatustc read-only
This value indicates the current status of this input device.
                         finSupplyMediaInputMediaName 1.3.6.1.2.1.43.32.1.1.9 octet string read-write
The name of the current media contained in this input device. Examples are Engineering Manual Cover, Section A Tab Divider or any ISO standard names.
                         finSupplyMediaInputName 1.3.6.1.2.1.43.32.1.1.10 octet string read-write
The name assigned to this input subunit.
                         finSupplyMediaInputDescription 1.3.6.1.2.1.43.32.1.1.11 octet string read-only
A free form text description of this input subunit in the localization specified by prtGeneralCurrentLocalization.
                         finSupplyMediaInputSecurity 1.3.6.1.2.1.43.32.1.1.12 presentonoff read-write
Indicates if this subunit has some security associated with it.
                         finSupplyMediaInputMediaWeight 1.3.6.1.2.1.43.32.1.1.13 integer32 read-write
The weight of the media associated with this Input device in grams per meter squared. The value (-1) means other and specifically indicates that the device places no restriction on this parameter. The value (-2) means unknown. This object can be used to calculate the weight of individual pages processed by the document finisher. This value, when multiplied by the number of pages in a finished set, can be used to calculate the weight of a set before it is inserted into a mailing envelope.
                         finSupplyMediaInputMediaThickness 1.3.6.1.2.1.43.32.1.1.14 integer32 read-write
This object identifies the thickness of the input media processed by this document input subunit measured in micrometers. This value may be used by devices (or operators) to set up proper machine tolerances for the feeder operation. The value (-2) indicates that the media thickness is unknown or not used in the setup for this input subunit.
                         finSupplyMediaInputMediaType 1.3.6.1.2.1.43.32.1.1.15 octet string read-write
The name of the type of medium associated with this input subunit. Valid values are standardized strings from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: stationary, transparency, envelope, envelope-plain, envelope window, continuous-long, continuous-short, tab-stock, labels, multi-layer.
           finDeviceAttribute 1.3.6.1.2.1.43.33
                 finDeviceAttributeTable 1.3.6.1.2.1.43.33.1 no-access
The attribute table defines special parameters that are applicable only to a minority of the finisher devices. An attribute table entry is used, rather than unique objects, to minimize the number of MIB objects and to allow for expansion without the addition of MIB objects. Each finisher device is represented by a separate row in the device subunit attribute table.
                     finDeviceAttributeEntry 1.3.6.1.2.1.43.33.1.1 no-access
Each entry defines a finisher function parameter that cannot be represented by an object in the finisher device subunit table.
                         finDeviceAttributeTypeIndex 1.3.6.1.2.1.43.33.1.1.1 finattributetypetc no-access
Defines the attribute type represented by this row.
                         finDeviceAttributeInstanceIndex 1.3.6.1.2.1.43.33.1.1.2 integer32 no-access
An index that allows the discrimination of an attribute instance when the same attribute occurs multiple times for a specific instance of a finisher function. The value of this index shall be 1 if only a single instance of the attribute occurs for the specific finisher function.
                         finDeviceAttributeValueAsInteger 1.3.6.1.2.1.43.33.1.1.3 integer32 read-write
Defines the integer value of the attribute. The value of the attribute is represented as an integer if the finAttributeTypeTC description for the attribute has the tag 'INTEGER:'. Depending upon the attribute enum definition, this object may be either an integer, a counter, an index, or an enum. Attributes for which the concept of an integer value is not meaningful SHALL return a value of -1 for this attribute.
                         finDeviceAttributeValueAsOctets 1.3.6.1.2.1.43.33.1.1.4 octet string read-write
Contains the octet string value of the attribute. The value of the attribute is represented as a string if the finAttributeTypeTC description for the attribute has the tag 'OCTETS:'. Depending upon the attribute enum definition, this object may be either a coded character set string (text) or a binary octet string. Attributes for which the concept of an octet string value is not meaningful SHALL contain a zero length string.
 finisherMIB 1.3.6.1.3.64
The MIB module for management of printer finisher units. The Finisher MIB is an extension of the Printer MIB.