Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
enterprises | 1.3.6.1.4.1 | |||
sni | 1.3.6.1.4.1.231 | |||
sniProductMibs | 1.3.6.1.4.1.231.2 | |||
sniExtensions | 1.3.6.1.4.1.231.2.10 | |||
sniServerMgmt | 1.3.6.1.4.1.231.2.10.2 | |||
sniInventory | 1.3.6.1.4.1.231.2.10.2.1 | |||
sniCommon | 1.3.6.1.4.1.231.2.10.2.2 | |||
fscServerControl2 | 1.3.6.1.4.1.231.2.10.2.2.10 | |||
sc2AgentInfo | 1.3.6.1.4.1.231.2.10.2.2.10.1 | |||
sc2AgentId | 1.3.6.1.4.1.231.2.10.2.2.10.1.1 | displaystring | read-only |
Agent identification string |
sc2AgentCompany | 1.3.6.1.4.1.231.2.10.2.2.10.1.2 | displaystring | read-only |
Agent's company name (e.g. Fujitsu Technology Solutions) |
sc2AgentVersion | 1.3.6.1.4.1.231.2.10.2.2.10.1.3 | displaystring | read-only |
Agent's version string (e.g. 1.05) |
sc2AgentBuild | 1.3.6.1.4.1.231.2.10.2.2.10.1.4 | displaystring | read-only |
Compilation time and date of agent program |
sc2AgentWriteAllowed | 1.3.6.1.4.1.231.2.10.2.2.10.1.5 | integer | read-only |
Defines whether writable objects can be written (except shutdown/power-off operations) Enumeration: 'unknown': 1, 'write-not-allowed': 2, 'write-allowed': 3. |
sc2AgentShutdownAllowed | 1.3.6.1.4.1.231.2.10.2.2.10.1.6 | integer | read-only |
Defines whether shutdown/power-off objects can be written Enumeration: 'unknown': 1, 'shutdown-not-allowed': 2, 'shutdown-allowed': 3. |
sc2UnitInformation | 1.3.6.1.4.1.231.2.10.2.2.10.2 | |||
sc2LocalServerUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.2.1 | integer | read-only |
Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the sc2Units table. |
sc2NumberUnits | 1.3.6.1.4.1.231.2.10.2.2.10.2.2 | integer | read-only |
Number of available units (size of sc2Units table). |
sc2UnitTable | 1.3.6.1.4.1.231.2.10.2.2.10.2.3 | no-access |
Description of all units in this MIB |
|
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1 | no-access | |||
sc2uUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2UnitClass | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.2 | unitclass | read-only |
Unit classification (type) |
sc2UnitCabinetNr | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.3 | integer | read-only |
Unit cabinet number (used for addressing storage extension cabinets or server blades). The ID of the local server is usually 0. |
sc2UnitDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.4 | displaystring | read-only |
Unit designation / housing type (e.g. 'H200R') |
sc2UnitModelName | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.5 | displaystring | read-only |
Unit model name (e.g. 'PRIMERGY RX100') |
sc2UnitManufacturer | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.6 | displaystring | read-only |
Unit manufacturer name (e.g. 'Fujitsu Technology Solutions') |
sc2UnitSerialNumber | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.7 | displaystring | read-only |
Unit serial number (e.g. 'YBCL123456') |
sc2UnitLocation | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.8 | displaystring | read-only |
Unit location string (e.g. 'ServerCenter Room 17, Rack 9') |
sc2UnitContact | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.9 | displaystring | read-only |
Unit contact name (e.g. 'Mr. Bond') |
sc2UnitAdminURL | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.10 | displaystring | read-only |
URL of administration HTML interface (e.g. 'http://MyServer/admin') |
sc2FrontDoorStatus | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.11 | integer | read-only |
Status describing whether the front door is open or closed Enumeration: 'unknown': 1, 'open': 2, 'closed': 3. |
sc2HousingOpenStatus | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.12 | integer | read-only |
Status describing whether the housing is open or closed Enumeration: 'unknown': 1, 'open': 2, 'closed': 3, 'opened-and-closed': 4. |
sc2MsgLogLanguages | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.13 | displaystring | read-only |
Supported languages of text message log (comma-seperated list of decimal language codes, see sc2MessageTextLogTable). e.g. '1031,1033' means German and English are supported. English (1033) is the default language and is always available. |
sc2UnitWorldWideName | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.14 | displaystring | read-only |
Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB') |
sc2RemcsId | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.15 | displaystring | read-only |
REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number |
sc2AssetTag | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.16 | displaystring | read-only |
Customer specific asset tag (40 bytes) |
sc2MsgLogAvailable | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.17 | truefalse | read-only |
Replies whether a message log is available on this unit |
sc2ManagementIpAddress | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.18 | displaystring | read-only |
IPv4 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv4 address string). |
sc2HasUefiFirmware | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.19 | truefalse | read-only |
Replies whether the system is equipped with UEFI firmware |
sc2ManagementIpAddressV6 | 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.20 | displaystring | read-only |
IPv6 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv6 address string). |
sc2UnitTableUpdateCount | 1.3.6.1.4.1.231.2.10.2.2.10.2.4 | counter | read-only |
Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update. |
sc2UnitParentTable | 1.3.6.1.4.1.231.2.10.2.2.10.2.5 | no-access |
Parent-child relationship of all units: list the parent of all available units. Only units that have a parent are listed in this table. |
|
1.3.6.1.4.1.231.2.10.2.2.10.2.5.1 | no-access | |||
sc2pUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2ParentUnit | 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.2 | integer | read-only |
Unit identifier of this unit's parent |
sc2ParentUnitClass | 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.3 | unitclass | read-only |
Parent unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection. |
sc2UnitChildTable | 1.3.6.1.4.1.231.2.10.2.2.10.2.6 | no-access |
Parent-child relationship of all units: list all children of all available units. Only units that have children are listed in this table. |
|
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1 | no-access | |||
sc2cUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2cChildNr | 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.2 | integer | read-only |
Child number (index, 1..n) |
sc2ChildUnit | 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.3 | integer | read-only |
Child unit |
sc2ChildUnitClass | 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.4 | unitclass | read-only |
Unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection. |
sc2Management | 1.3.6.1.4.1.231.2.10.2.2.10.3 | |||
sc2ManagementNodeTable | 1.3.6.1.4.1.231.2.10.2.2.10.3.1 | no-access |
SNMP management node addresses (how to address the units) |
|
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1 | no-access | |||
sc2mnUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2mnNodeNr | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.2 | integer | read-only |
Management node address number (index, 1..n) |
sc2UnitNodeIfType | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.3 | integer | read-only |
Management node interface type Enumeration: 'unknown': 1, 'ipx': 3, 'ip-v6': 4, 'ip': 2. |
sc2UnitNodeAddress | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.4 | displaystring | read-only |
Management node address (e.g. 192.168.0.100) |
sc2UnitNodeIpNetmask | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.5 | displaystring | read-only |
Management node address (e.g. 255.255.255.128) |
sc2UnitNodeGateway | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.6 | displaystring | read-only |
Management node address (e.g. 192.168.0.126) |
sc2UnitNodeName | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.7 | displaystring | read-only |
Management node name (DNS name, e.g. apollo.ts.fujitsu.com) |
sc2UnitNodeClass | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.8 | integer | read-only |
Management node class: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interface (in a blade server chassis) secondary-remote: remote management controller (in an RSB concentrator environment) secondary-remote-backup: backup remote management controller baseboard-controller: local baseboard management controller (BMC) Enumeration: 'unknown': 1, 'secondary-remote-backup': 6, 'primary': 2, 'management-blade': 4, 'secondary-remote': 5, 'baseboard-controller': 7, 'secondary': 3. |
sc2UnitNodeMacAddress | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.9 | physaddress | read-only |
Management node hardware (MAC) address |
sc2UnitNodeUseDHCP | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.10 | integer | read-only |
Management node uses DHCP to obtain its address Enumeration: 'unknown': 1, 'use-fixed-address': 2, 'use-dhcp': 3. |
sc2UnitNodeControllerType | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.11 | displaystring | read-only |
The type of the remote management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once. |
sc2UnitNodeControllerModel | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.12 | displaystring | read-only |
The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used for identification, only for displaying (can be changed in different firmware versions)! |
sc2UnitNodeControllerFWVersion | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.13 | displaystring | read-only |
The FW version of the remote management controller |
sc2UnitNodeControllerStorage | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.14 | integer | read-only |
Status of the controller specific external storage used for the system management. Enumeration: 'not-available': 2, 'unknown': 1, 'available-sdcard': 3. |
sc2UnitNodeSNMPEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.15 | truefalseunknown | read-only |
SNMP interface is enabled at management node |
sc2UnitNodeCIMEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.16 | truefalseunknown | read-only |
CIM protocol is enabled at management node |
sc2UnitNodeRemoteIPMIEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.17 | truefalseunknown | read-only |
Remote IPMI is enabled at management node |
sc2NodeTableUpdateCount | 1.3.6.1.4.1.231.2.10.2.2.10.3.2 | counter | read-only |
Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update. |
sc2ManagementChannelType | 1.3.6.1.4.1.231.2.10.2.2.10.3.3 | integer | read-only |
The type of the management channel currently used (this MIB instance). Enumeration: 'unknown': 1, 'primary': 2, 'secondary': 3. |
sc2ManagementProcessorTable | 1.3.6.1.4.1.231.2.10.2.2.10.3.4 | no-access |
System management service processors |
|
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1 | no-access | |||
sc2spUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2spProcessorNr | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.2 | integer | read-only |
Service processor number (index, 1..n) |
sc2spModelName | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.3 | displaystring | read-only |
Service processor model name |
sc2spFirmwareVersion | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.4 | displaystring | read-only |
Service processor firmware version / revision |
sc2spBatteryStatus | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.5 | integer | read-only |
Service processor backup battery status Enumeration: 'discharging': 7, 'ok': 3, 'unknown': 1, 'recharging': 5, 'failed': 6, 'not-present': 2, 'on-battery': 4. |
sc2spBatteryDischargeTime | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.6 | integer | read-only |
Maximum time (in seconds) this backup battery can discharged, after that a shutdown will be performed (-1 = unknown) |
sc2spTimeOnBattery | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.7 | counter | read-only |
Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery) |
sc2spDoBatteryChargeCycle | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.8 | integer | read-write |
Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0. |
sc2spBatteryChargeLevel | 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.9 | gauge | read-only |
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity). |
sc2ManagedUpsNodeTable | 1.3.6.1.4.1.231.2.10.2.2.10.3.5 | no-access |
UPS nodes managed by the units |
|
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1 | no-access | |||
sc2upsUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2upsNr | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.2 | integer | read-only |
UPS number (index, 1..n) |
sc2upsVendorName | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.3 | displaystring | read-only |
UPS vendor name |
sc2upsModelName | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.4 | displaystring | read-only |
UPS model name |
sc2upsMgmtAddress | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.5 | displaystring | read-only |
UPS management interface target address (represented as string; may contain an IP V4 address, IP V6 address or a URL) |
sc2upsMibRoot | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.6 | displaystring | read-only |
UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available) |
sc2upsSnmpCommunity | 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.7 | displaystring | read-only |
UPS SNMP community name (empty string if no SNMP agent available) |
sc2UpsNodeTableUpdateCount | 1.3.6.1.4.1.231.2.10.2.2.10.3.6 | counter | read-only |
Counter defining the update revision of the UPS node table. This counter is incremented with every table contents change/update. |
sc2ServerInformation | 1.3.6.1.4.1.231.2.10.2.2.10.4 | |||
sc2ServerTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.1 | no-access |
Table containing information about the available servers |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1 | no-access | |||
sc2srvUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2srvPhysicalMemory | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.2 | integer | read-only |
Size of physical main memory installed (MBytes) |
sc2srvLastBootResult | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.3 | integer | read-only |
Result of last system boot Enumeration: 'no-boot-cp': 4, 'diagnostic-boot-failed': 7, 'os-boot-successful': 2, 'unknown': 1, 'diagnostic-boot-successful': 3, 'hardware-failure': 8, 'no-bootable-media': 5, 'os-failed-to-load': 6. |
sc2srvCurrentBootStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.4 | integer | read-only |
Status of the current boot Enumeration: 'no-boot-cp': 3, 'reset': 12, 'os-shutdown': 10, 'off': 2, 'unknown': 1, 'setup': 5, 'diagnostic-shutdown': 11, 'os-boot': 6, 'os-running': 8, 'diagnostic-boot': 7, 'self-test': 4, 'diagnostic-running': 9. |
sc2srvShutdownCommand | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.5 | integer | read-write |
Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; when reading that value, always unknown(1) is replied; argument tells what kind of action: power-on: switch power on power-off: switch power off power-cycle: switch power off and switch power on again. shutdown-and-off: execute a shutdown then power off shutdown-and-reset: execute a shutdown then reset shutdown-and-power-cycle: execute a shutdown then power off and on again raise-nmi: raise an NMI (normally causes debugger to start) reset: execute a reset (without shutdown) The value unknown(1) cannot be set. Enumeration: 'reset': 10, 'power-off': 2, 'unknown': 1, 'raise-nmi': 8, 'power-on': 3, 'shutdown-and-off': 5, 'shutdown-and-reset': 6, 'abort-pending-command': 9, 'shutdown-and-power-cycle': 7, 'power-cycle': 4. |
sc2srvShutdownDelay | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.6 | integer | read-write |
Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action, no delay -1 = unknown (delay not supported) The value unknown(-1) cannot be set. |
sc2srvUUID | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.7 | displaystring | read-only |
Universal Unique ID (UUID) number (as specified in RFC 4122; shown in network byte order, big-endian) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '33221100-5544-7766-8899-AABBCCDDEEFF' |
sc2srvPhysicalMemoryOs | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.8 | integer | read-only |
Size of physical main memory available to the operating system (MBytes). This value is similar to 'sc2srvPhysicalMemory', but may be less if the system has mirror or hot spare memory modules. |
sc2srvUUIDWireFormat | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.9 | displaystring | read-only |
Universal Unique ID (UUID) number (shown in the wire format; little-endian for the first three fields, as consistently used in the PC industry) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '00112233-4455-6677-8899-AABBCCDDEEFF' |
sc2srvOsPlatform | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.10 | integer | read-only |
Reports about the current operating system platform (x86, x64) Enumeration: 'intel-x86': 2, 'other': 1, 'intel-x64': 3. |
sc2srvBiosVersion | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.11 | displaystring | read-only |
System BIOS version |
sc2srvHasEncryptedPartitions | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.12 | truefalseunknown | read-only |
Specifies whether encrypted file systems (e.g. by Windows BitLocker) are used (may prevent from BIOS updates) |
sc2srvTrustedExecutionTechnologyEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.13 | truefalseunknown | read-only |
Specifies whether Intel Trusted Execution Technology (TXT) is enabled (may prevent from BIOS updates) |
sc2UnitPowerOnOffTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.2 | no-access |
Unit power-on and -off information |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1 | no-access | |||
sc2ooUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2PowerOnOffStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.2 | integer | read-only |
Current power on/off status Enumeration: 'unknown': 1, 'off': 2, 'on': 3. |
sc2LastPowerOffSource | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.3 | integer | read-only |
Reason why the system was switched off last time Enumeration: 'remote-off': 11, 'fan-fail': 6, 'repeated-fan-fail': 40, 'viom-inventory-board': 38, 'power-limiting': 35, 'watchdog-power-cycle': 37, 'temperature-damage': 8, 'keyboard': 29, 'watchdog': 10, 'power-supply-failure': 9, 'power-button': 3, 'ac-fail': 4, 'clock': 5, 'swoff-command': 2, 'unknown': 1, 'temperature-critical': 7, 'warmstart': 24, 'power-cycle': 33, 'reset-button': 25, 'repeated-temperature-critical': 41, 'viom-init-boot': 39, 'firmware-restart': 242, 'cpu-error': 14, 'remote-manager-reset': 32, 'hardware-reset': 23, 'nmi': 20, 'mmb-continuous-operation': 36, 'peripheral-bus-error': 13, 'remote-manager': 31, 'hardware-fail': 12, 'ac-fail-reboot': 26, 'housing-opened': 243. |
sc2LastPowerOnSource | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.4 | integer | read-only |
Source the system was switched on from Enumeration: 'fan-fail': 6, 'chipcard-reader': 30, 'temperature-damage': 8, 'keyboard': 29, 'watchdog': 10, 'power-supply-failure': 9, 'power-button': 3, 'ac-fail': 4, 'clock': 5, 'swoff-command': 2, 'unknown': 1, 'mgmt-processor-fail': 27, 'temperature-critical': 7, 'warmstart': 24, 'power-cycle': 33, 'reset-button': 25, 'viom-init-boot': 39, 'pci-pme': 28, 'remote-on': 11, 'firmware-restart': 242, 'cpu-error': 14, 'viom-inventory-board': 38, 'remote-manager-reset': 32, 'hardware-reset': 23, 'nmi': 20, 'peripheral-bus-error': 13, 'remote-manager': 31, 'housing-closed': 243, 'hardware-fail': 12, 'ac-fail-reboot': 26. |
sc2LastPowerOnTime | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.5 | integer | read-only |
Time and date (UTC) the system was booted (seconds since 1/1/1970; 0 = unknown or not available) |
sc2PowerOnCounts | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.6 | integer | read-only |
Tells how often the server was switched on in its life (0 = unknown or not available) |
sc2PowerOnDuration | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.7 | integer | read-only |
Tells how long the system has stayed ON in its life (in seconds; 0 = unknown or not available) |
sc2PowerOffDuration | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.8 | integer | read-only |
Tells how long the system has stayed OFF in its life (in seconds; 0 = unknown or not available) |
sc2PowerFailRecovery | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.9 | integer | read-only |
Action on AC power recovery after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-available': 2, 'unknown': 1, 'remain-off': 4, 'switch-on': 5, 'as-before': 3. |
sc2PowerCommand | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.10 | integer | read-write |
Switch the unit on or off; mainly used for extension cabinets; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again No graceful system shutdown is performed - use sc2srvShutdownCommand if shutdown of a server is requested! The value unknown(1) cannot be set and will be delivered if the object is read. Enumeration: 'unknown': 1, 'off': 2, 'power-cycle': 4, 'on': 3. |
sc2PowerSupplyRedundancy | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.11 | truefalseunknown | read-only |
Specifies whether the power supply system contains redundant power supplies and whether redundancy is available |
sc2PowerSupplyMatchStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.12 | integer | read-only |
Status of power supply matching - 'ok' if power supplies do not mismatch Enumeration: 'mismatch': 3, 'unknown': 1, 'ok': 2. |
sc2PerformanceTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.3 | no-access |
Server performance and utilisation information (Obsolete! Please use sc2PerformanceValueTable!) |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1 | no-access | |||
sc2perfUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2perfNr | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.2 | integer | read-only |
Server performance entry number (index, 1..n) |
sc2PerformanceType | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.3 | integer | read-only |
Server performance object type (description see below) Enumeration: 'memory-physical': 6, 'memory-percent': 8, 'pci-transfer': 5, 'cp': 1, 'memory-total': 7, 'pci-efficiency': 4, 'cpu-overall': 2, 'pci-load': 3. |
sc2PerformanceObjectNr | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.4 | integer | read-only |
Server performance object number (0..n; for types with multiple objects) |
sc2PerformanceName | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.5 | displaystring | read-only |
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend. |
sc2PerformanceValue | 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.6 | gauge | read-only |
Server performance value (value interpretation depending on type; 0xffffffff = unknown): cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in percent pci-load: PCI bus load in percent pci-efficiency: PCI bus efficiency in percent (100% is optimum) pci-transfer: PCI bus transfer rate in MBytes/sec. memory-physical: Physical memory usage in MBytes memory-total: Total memory usage (physical + virtual) in MBytes memory-percent: Physical memory usage in percent |
sc2TimerOnOffTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.4 | no-access |
Power on/off timer table |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1 | no-access | |||
sc2tooUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2tooDayOfWeek | 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.2 | integer | read-only |
Day of the week the times should act upon (index); 1=Sunday, 2=Monday... |
sc2OnTime | 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.3 | integer | read-write |
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed. |
sc2OffTime | 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.4 | integer | read-write |
Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed. |
sc2PowerMonitoringTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.5 | no-access |
Power monitoring table |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1 | no-access | |||
sc2pmUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2pmCurrentPowerMonitoringAvailable | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.2 | truefalse | read-only |
Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not available |
sc2pmCurrentPowerMonitoringEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.3 | truefalse | read-only |
Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available |
sc2pmNominalPowerConsumption | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.4 | integer | read-only |
Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available) |
sc2pmCurrentPowerConsumption | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.5 | gauge | read-only |
Current value of the system's power consumption (in Watts; -1 if value not available) |
sc2pmCurrentPowerControl | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.6 | integer | read-only |
Power mode control value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise Enumeration: 'limited': 7, 'minimum-power': 4, 'unknown': 1, 'low-noise': 8, 'best-performance': 3, 'disabled': 2, 'automatic': 5. |
sc2pmPowerLimitStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.7 | integer | read-only |
Power limitation status (valid if power control = limited) ok: power consumption is within specified range warning: power consumption is above warning threshold (sc2pmPowerLimitWarning) but below limit error: power consumption is above limit (sc2pmPowerLimitThreshold) disabled: power consumption limiting is disabled Enumeration: 'disabled': 5, 'unknown': 1, 'warning': 3, 'ok': 2, 'error': 4. |
sc2pmPowerLimitThreshold | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.8 | integer | read-only |
Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled) |
sc2pmPowerLimitWarning | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.9 | integer | read-only |
Warning limit level (in percent of the maximum limit threshold; 0 if value not available; only valid if limiting enabled) |
sc2pmRedundancyCritLevel | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.10 | integer | read-only |
Upper critical power consumption level (in Watts; -1 if value not available); power supply redundancy lost if level is exceeded |
sc2pmPowerControlMode | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.11 | integer | read-only |
Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise Enumeration: 'scheduled': 6, 'minimum-power': 4, 'limited': 7, 'unknown': 1, 'low-noise': 8, 'best-performance': 3, 'disabled': 2, 'automatic': 5. |
sc2pmPowerDisplayUnit | 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.12 | integer | read-only |
Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed in Btu Enumeration: 'watt': 2, 'unknown': 1, 'bt': 3. |
sc2UtilizationHistoryTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.6 | no-access |
Utilization history table (for power consumption); table only contains existing values (no values for non-existing values) |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1 | no-access | |||
sc2uthUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2uthEntity | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.2 | integer | read-only |
Utilization value entity; describes what kind of value to be requested: powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) per minute powerConsumptionMonth: power consumption values of the last month; one value (Watts) per hour powerConsumptionYear: power consumption values of the last year; one value (Watts) per day Enumeration: 'powerConsumptionYear': 3, 'powerConsumptionDay': 1, 'powerConsumptionMonth': 2. |
sc2uthTimeStamp | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.3 | integer | read-only |
Time stamp of the currenty history entry (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
sc2uthHardwareUUID | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.4 | displaystring | read-only |
UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade environments) |
sc2uthAverageValue | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.5 | gauge | read-only |
Average value (in Watts) within the monitored time period (minute, hour, day) |
sc2uthMinValue | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.6 | gauge | read-only |
Minimum (lowest) value within the monitored time period |
sc2uthMaxValue | 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.7 | gauge | read-only |
Maximum (highest) value within the monitored time period |
sc2PowerSourceInformationTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.7 | no-access |
Power source information table |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1 | no-access | |||
sc2psiUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2psiPowerSourceType | 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.2 | displaystring | read-only |
System input power source type (e.g. 'AC', 'DC') |
sc2psiPowerSourcePhase | 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.3 | integer | read-only |
System input phase of power source. Enumeration: 'unknown': 1, 'three-phase': 3, 'single-phase': 2. |
sc2psiPowerSourceVoltage | 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.4 | integer | read-only |
System nominal input voltage of power source (in Volts; -1 if value not available). |
sc2VirtualIoManagerTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.8 | no-access |
Virtual I/O Manager (VIOM) information table |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1 | no-access | |||
sc2viomUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2viomCurrentManagerId | 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.2 | displaystring | read-only |
Identification string of the VIOM manager that currently manages this server |
sc2viomEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.3 | truefalseunknown | read-only |
True if the server is enabled for VIOM |
sc2viomBiosSupport | 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.4 | truefalseunknown | read-only |
True if the BIOS supports VIOM |
sc2viomConnectionStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.5 | integer | read-only |
The connection status for VIOM - bit field: Bit 0 - waiting for VIOM table Bit 1 - waiting for inventory table Bit 2 - waiting for external power-on event |
sc2PowerSupplyRedundancyConfigurationTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.9 | no-access |
Power Supply redundancy configuration table |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1 | no-access | |||
sc2PSRedUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2PSRedundancyMode | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.2 | integer | read-only |
Configured power supply redundancy mode; configured in Server Configuration Enumeration: 'psu-redundancy': 4, 'triple-ac-redundancy': 34, 'unknown': 1, 'dual-ac-redundancy': 18, 'no-redundancy': 3, 'not-specified': 2. |
sc2PSRedundancyModeConfig | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.3 | integer | read-only |
Configuration of number required power supplies for the different redundancy modes specified in sc2PSRedundancyMode: no-redundancy(2): no redundancy required redundancy-1-1(19): 1 required + 1 spare PSU (psu-redundancy mode) or 1 PSU per AC phase (dual-ac-redundancy mode) redundancy-2-1(35): 2 required + 1 spare PSU (psu-redundancy mode) redundancy-3-1(51): 3 required + 1 spare PSU (psu-redundancy mode) redundancy-2-2(36): 2 PSUs per AC phase (dual-ac-redundancy mode) Enumeration: 'redundancy-1-1': 19, 'redundancy-3-1': 51, 'redundancy-2-1': 35, 'unknown': 1, 'redundancy-2-2': 36, 'no-redundancy': 2. |
sc2PSRedundancyRequiredPowerSupplies | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.4 | integer | read-only |
Number of power supplies required for configured redundancy mode |
sc2PSRedundancyPopulatedPowerSupplies | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.5 | integer | read-only |
Number of power supplies populated for configured redundancy mode |
sc2PSRedundancyConfigurationStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.6 | compstatus | read-only |
Status of the redundancy configuration; reports the status about whether enough power supplies are installed to operate at the configured redundancy mode |
sc2PSRedundancyThresholdStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.7 | compstatus | read-only |
Status of redundancy threshold; reports the status about whether the actual power consumption exceeds the maximum power consumption level for the configured redundancy mode. |
sc2PSRedundancyStatus | 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.8 | integer | read-only |
Status of power supply redundancy; similar to sc2PowerSupplyRedundancy, but with additional status evaluation according to the power supply redundancy configuration. not-available(2): redundancy not required and not available (no error) ok(3): redundancy required and available warning(4): redundancy required but not available error(5): redundancy required but severe problem detected Enumeration: 'not-available': 2, 'unknown': 1, 'warning': 4, 'ok': 3, 'error': 5. |
sc2PerformanceValueTable | 1.3.6.1.4.1.231.2.10.2.2.10.4.10 | no-access |
Server performance and utilisation values |
|
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1 | no-access | |||
sc2PerfValUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.1 | integer | read-only |
Unit identifier (index, 1..n). For performacne values on local system use 1! |
sc2PerfValType | 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.2 | integer | read-only |
Server performance object type (description see below) Enumeration: 'logicalCpuUsagePercent': 6, 'totalMemoryUsagePercent': 4, 'physicalMemoryUsagePercent': 2, 'totalMemoryUsageMb': 3, 'overallCpuUsagePercent': 5, 'physicalMemoryUsageMb': 1. |
sc2PerfValObjectNr | 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.3 | integer | read-only |
Server performance object number (1..n; for types with multiple objects) |
sc2PerfValName | 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.4 | displaystring | read-only |
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend. |
sc2PerfValCurrentValue | 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.5 | gauge | read-only |
Server performance value (value interpretation depending on type; 0xffffffff = unknown): physicalMemoryUsageMb: Physical memory usage in MBytes physicalMemoryUsagePercent: Physical memory usage in percent totalMemoryUsageMb: Total memory usage (physical + virtual) in MBytes totalMemoryUsagePercent: Total memory usage (physical + virtual) in percent overallCpuUsagePercent: Overall CPU load in percent logicalCpuUsagePercent: Load of a single CPU in percent |
sc2Environment | 1.3.6.1.4.1.231.2.10.2.2.10.5 | |||
sc2TemperatureSensorTable | 1.3.6.1.4.1.231.2.10.2.2.10.5.1 | no-access |
Temperature sensors |
|
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1 | no-access | |||
sc2tempUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2tempSensorNr | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.2 | integer | read-only |
Temperature sensor number (index, 1..n) |
sc2tempSensorDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.3 | displaystring | read-only |
Temperature sensor designation (e.g. TEMP-PS1) |
sc2tempSensorIdentifier | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4 | displaystring | read-only |
Temperature sensor identification string (e.g. TEMP-RSB1) |
sc2tempSensorStatus | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5 | integer | read-only |
Status of the temperature sensor Enumeration: 'not-available': 2, 'ok': 3, 'sensor-failed': 4, 'temperature-warning': 9, 'temperature-critical-toohot': 7, 'unknown': 1, 'failed': 5, 'temperature-warning-toohot': 6, 'temperature-normal': 8. |
sc2tempCurrentTemperature | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6 | gauge | read-only |
Current temperature at this sensor (degrees Celsius; 0 if unknown or sensor failed) |
sc2tempWarningLevel | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7 | integer | read-only |
Maximum temperature - warning level (degrees Celsius; 0 if unknown or undefined) |
sc2tempCriticalLevel | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8 | integer | read-only |
Maximum temperature - critical level (degrees Celsius; 0 if unknown or undefined), system shutdown may occur if this level is exceeded |
sc2tempCriticalReaction | 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9 | integer | read-write |
Reaction if temperature exceeds the critical level (the value unknown(1) cannot be set) Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2. |
sc2FanTable | 1.3.6.1.4.1.231.2.10.2.2.10.5.2 | no-access |
Cooling devices (fans, liquid cooling pumps) |
|
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1 | no-access | |||
sc2fanUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2fanNr | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.2 | integer | read-only |
Cooling device number (index, 1..n) |
sc2fanDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3 | displaystring | read-only |
Cooling device designation (e.g. FAN-PS1) |
sc2fanIdentifier | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.4 | displaystring | read-only |
Cooling device identification string (e.g. FAN-1-POWERSUPPLY) |
sc2fanStatus | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5 | integer | read-only |
Status of the cooling device Enumeration: 'redundant-fan-failed': 6, 'ok': 3, 'prefailure-predicted': 5, 'unknown': 1, 'disabled': 2, 'failed': 4, 'not-manageable': 7, 'not-present': 8. |
sc2fanCurrentSpeed | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6 | gauge | read-only |
Current cooling device speed (revolutions per minute; 0 if unknown or failed) |
sc2fanQuality | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.7 | gauge | read-only |
Quality of cooling device (in percent of nominal speed - measured at full speed) |
sc2fanFailReaction | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.8 | integer | read-write |
Reaction if the cooling device fails (the value unknown(1) cannot be set) Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2. |
sc2fanFailShutdownDelay | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.9 | integer | read-write |
Delay time (in seconds) when shutdown should commit on cooling device fail (if shutdown-and-off is configured; 0 = immediately, -1 = unknown, cannot be set) |
sc2fanCoolingDeviceType | 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.10 | integer | read-only |
Type of cooling device (whether fan or liquid cooling pump) fan(2): fan liquid(3): liquid cooling pump Enumeration: 'unknown': 1, 'fan': 2, 'liquid': 3. |
sc2AirflowTable | 1.3.6.1.4.1.231.2.10.2.2.10.5.3 | no-access |
Exhaust airflow volume table |
|
1.3.6.1.4.1.231.2.10.2.2.10.5.3.1 | no-access | |||
sc2afUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2afExhaustAirflowVolume | 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.2 | integer | read-only |
System exhaust airflow volume ('-1' if value not available) |
sc2afExhaustAirflowVolumeUnit | 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.3 | displaystring | read-only |
System exhaust airflow volume unit (e.g. 'cbm/h', 'ccm/min', ...) |
sc2Hardware | 1.3.6.1.4.1.231.2.10.2.2.10.6 | |||
sc2SystemBoardTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.1 | no-access |
System board (main board) information |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1 | no-access | |||
sc2sbUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2sbBoardNr | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.2 | integer | read-only |
System board number (index, 1..n) |
sc2SystemBoardModelName | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.3 | displaystring | read-only |
Model name (e.g. 'D1297') |
sc2SystemBoardProductNumber | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.4 | displaystring | read-only |
Product number (may be identical to ModelName) |
sc2SystemBoardRevision | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.5 | displaystring | read-only |
Revision string (e.g. 'WGS1 GS3') |
sc2SystemBoardSerialNumber | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.6 | displaystring | read-only |
Serial number (not available for all boards) |
sc2SystemBoardDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.7 | displaystring | read-only |
Designation (important when multiple system boards are available) |
sc2SystemBoardSDCardSlotPresent | 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.8 | truefalseunknown | read-only |
System board contains SD card slot |
sc2PowerSupplyTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.2 | no-access |
Power supplies |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1 | no-access | |||
sc2psUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2psPowerSupplyNr | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.2 | integer | read-only |
Power supply (bay) number (index, 1..n) |
sc2PowerSupplyDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.3 | displaystring | read-only |
Power supply designation (e.g. PS1) |
sc2PowerSupplyIdentifier | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4 | displaystring | read-only |
Power supply identification string (e.g. PS1) |
sc2PowerSupplyStatus | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5 | integer | read-only |
Power supply status Enumeration: 'not-manageable': 8, 'ok': 3, 'fan-failure': 10, 'ac-fail': 5, 'unknown': 1, 'non-redundant-ac-fail': 13, 'critical-temperature': 7, 'non-redundant-dc-fail': 12, 'failed': 4, 'not-present': 2, 'power-safe-mode': 11, 'dc-fail': 6, 'fan-failure-predicted': 9. |
sc2psPowerSupplyLoad | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.6 | integer | read-only |
Actual power supply output load in Watts (0 = not available) |
sc2psPowerSupplyNominal | 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.7 | integer | read-only |
Nominal power supply output load in Watts (0 = not available), the maximum value the power supply can provide |
sc2VoltageTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.3 | no-access |
Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown) |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1 | no-access | |||
sc2voUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2voSensorNr | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.2 | integer | read-only |
Voltage sensor number (index, 1..n) |
sc2VoltageDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3 | displaystring | read-only |
Voltage designation string (e.g. 12V, 3V3, ...) |
sc2VoltageStatus | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4 | integer | read-only |
Voltage status not-available(2): no voltage available (e.g. CPU voltage on empty CPU socket) ok(3): voltage value is in normal range too-low(4): voltage value is below nominal range too-high(5): voltage value is above upper limit out-of-range(6): voltage value is out of normal range (cannot detect whether too low or too high) warning(7): voltage warning (e.g. battery failure predicted) Enumeration: 'not-available': 2, 'ok': 3, 'unknown': 1, 'out-of-range': 6, 'warning': 7, 'too-low': 4, 'too-high': 5. |
sc2VoltageCurrentValue | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.5 | gauge | read-only |
Voltage current value (in mV; 0xFFFFFFFF = unknown; negative voltages are reported as negative values: -1770 (0xFFFFF916) means -1.77 Volts) |
sc2VoltageNominalValue | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.6 | integer | read-only |
Voltage nominal value (in mV; -1 = unknown; negative voltages are reported as negative values) |
sc2VoltageMinimumLevel | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.7 | integer | read-only |
Voltage minimum level (in mV; -1 = unknown; negative voltages are reported as negative values) |
sc2VoltageMaximumLevel | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.8 | integer | read-only |
Voltage maximum level (in mV; -1 = unknown; negative voltages are reported as negative values) |
sc2VoltageCurrentLoad | 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.9 | gauge | read-only |
Current output load on this voltage line, in percent of the maximum load (0xFFFFFFFF = unknown) |
sc2CPUTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.4 | no-access |
CPU description table |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1 | no-access | |||
sc2cpuUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2cpuNr | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.2 | integer | read-only |
CPU (socket) number (index, 1..n) |
sc2cpuDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.3 | displaystring | read-only |
CPU designation (e.g. CPU-2) |
sc2cpuStatus | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.4 | integer | read-only |
CPU status: unknown(1): CPU status could not be evaluated not-present(2): CPU socket is empty ok(3): CPU is available and working properly disabled(4): CPU was manually disabled in BIOS setup error(5): CPU has encountered errors but is still in use failed(6): CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8): CPU has encountered too many correctable errors within a certain time period and is predicted to fail in near future Enumeration: 'ok': 3, 'prefailure-warning': 8, 'unknown': 1, 'disabled': 4, 'failed': 6, 'not-present': 2, 'error': 5, 'missing-termination': 7. |
sc2cpuModelName | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.5 | displaystring | read-only |
CPU model name (e.g. Pentium Xeon) |
sc2cpuManufacturer | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.6 | displaystring | read-only |
CPU manufacturer name (e.g. Intel) |
sc2cpuStep | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.7 | displaystring | read-only |
CPU step / revision |
sc2cpuCurrentSpeed | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.8 | integer | read-only |
CPU speed (frequency in MHz, -1 if unknown) |
sc2cpuNumberLogicals | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.9 | integer | read-only |
Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU, -1 if unknown or not available. |
sc2cpuCacheL1Size | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.10 | integer | read-only |
Size of first level cache (in kBytes, 0 if unknown or not available) |
sc2cpuCacheL2Size | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.11 | integer | read-only |
Size of second level cache (in kBytes, 0 if unknown or not available) |
sc2cpuCacheL3Size | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.12 | integer | read-only |
Size of third level cache (in kBytes, 0 if unknown or not available) |
sc2cpuNumberCores | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.13 | integer | read-only |
Number of (physically available) cores within one physical CPU (for multi-core CPUs, platform dependent), 0 if unknown or not available |
sc2cpuFamily | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.14 | integer | read-only |
CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information, type 4). |
sc2cpuEnabledCores | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.15 | integer | read-only |
Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown) |
sc2cpuMultithreadingEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.16 | integer | read-only |
Multithreading of CPU enabled Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3. |
sc2cpuConfigurationStatus | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.17 | integer | read-only |
CPU configuration status: unknown(1): CPU status could not be evaluated normal(2): Regular CPU configuration disabledManually(3): CPU was manually disabled (in BIOS setup) hotSpare(4): CPU is a hot-spare CPU (for future use) mirror(5): CPU is mirrored (for future use) notUsable(7): CPU is currently not usable (due to configuration problems) configurationError(8): CPU misconfiguration Enumeration: 'notUsable': 7, 'disabledManually': 3, 'unknown': 1, 'normal': 2, 'hotSpare': 4, 'configurationError': 8, 'mirror': 5. |
sc2cpuMCDRAMSize | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.18 | integer | read-only |
Size of the onboard MCDRAM (GByte; 0 if no MCDRAM is available) |
sc2cpuMCDRAMSpeed | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.19 | integer | read-only |
Speed of the onboard MCDRAM (MT/s; 0 if no MCDRAM is available) |
sc2cpuMCDRAMMode | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.20 | integer | read-only |
Operation mode of the onboard MCDRAM: undefined(1): Mode is not defined (no MCDRAM available) flat(2): MCDRAM is used as standalone memory exclusively or in addition to external RAM cache(3): MCDRAM is used as a cache for external RAM hybrid(3): Part of MCDRAM is used as a cache, rest as standalone memory (see sc2cpuMCDRAMCacheSize) Enumeration: 'flat': 2, 'cache': 3, 'hybrid': 3, 'undefined': 1. |
sc2cpuMCDRAMCacheSize | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.21 | integer | read-only |
Portion of the onboard MCDRAM used as a cache in hybrid mode (in percent; 0 if no MCDRAM is available or other mode than hybrid) |
sc2cpuMCDRAMMemoryModel | 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.22 | integer | read-only |
Memory model of the onboard MCDRAM: undefined(1): Model is not defined (no MCDRAM available) all2all(2): All2All subNumaCluster2(3): Sub NUMA Cluster - 2 subNumaCluster4(4): Sub NUMA Cluster - 4 hemisphere(5): Hemisphere mode quadrant(6): Quadrant mode Enumeration: 'undefined': 1, 'subNumaCluster4': 4, 'subNumaCluster2': 3, 'quadrant': 6, 'hemisphere': 5, 'all2all': 2. |
sc2MemoryModuleTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.5 | no-access |
Main memory module table |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1 | no-access | |||
sc2memUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2memModuleNr | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.2 | integer | read-only |
Memory module (socket) number (index, 1..n) |
sc2memModuleDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.3 | displaystring | read-only |
Memory module designation (e.g. DIMM-2) |
sc2memModuleStatus | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.4 | integer | read-only |
Memory module status: unknown(1): Module status could not be evaluated not-present(2): Module socket is empty ok(3): Module is available and working properly disabled(4): Module was manually disabled in BIOS setup error(5): Module has encountered errors but is still in use failed(6): Module has failed and was disabled prefailure-predicted(7): Module has encountered too many correctable errors within a certain time period and is predicted to fail in near future hidden(11): Module socket is not available and should be hidden Enumeration: 'ok': 3, 'prefailure-predicted': 7, 'unknown': 1, 'mirror': 9, 'disabled': 4, 'failed': 6, 'not-present': 2, 'error': 5, 'raid': 10, 'hot-spare': 8, 'hidden': 11. |
sc2memModuleBank | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.5 | integer | read-only |
Memory module bank number (-1 if unknown) Due to the fact that modern mainboards do no longer have fixed banks, this value is OBSOLETE! |
sc2memModuleCapacity | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.6 | integer | read-only |
Memory module size (capacity in MBytes; -1 if unknown) |
sc2memModuleStartAddress | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.7 | integer | read-only |
Memory module start address (in MBytes; -1 if unknown) Due to the fact that modern mainboards do no longer show start addresses, this value is OBSOLETE! |
sc2memModuleForm | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.8 | displaystring | read-only |
Memory module form (SIMM, DIMM, ...) |
sc2memModuleType | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.9 | displaystring | read-only |
Memory module type (SDRAM, DDRAM, DDR2, DDR3, ...) |
sc2memModuleCorrErrors | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.10 | counter | read-only |
Number of memory module correctable errors (-1 if unknown) |
sc2memModuleUncorrErrors | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.11 | counter | read-only |
Number of memory module uncorrectable errors (-1 if unknown) |
sc2memModuleApproved | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.12 | integer | read-only |
Memory module approved for this machine Enumeration: 'unknown': 1, 'yes': 3, 'no': 2. |
sc2memModuleConfiguration | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.13 | integer | read-only |
Memory module configuration: unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empty disabled(3): Module is disabled (manually through BIOS setup) hotSpare(4): Module is a hot-spare (standby) module, which will be used as a run-time-replacement for failed modules mirror(5): Module is part of a mirror configuration raid(6): Module is part of a RAID configuration notUsable(7): Module is not usable in the actual configuration because of architectural restrictions configurationError(8): Module is not active due to memory misconfiguration This object replaces the previous redundancy status values hot-spare and mirror in sc2memModuleStatus. Enumeration: 'raid': 6, 'notUsable': 7, 'normal': 2, 'unknown': 1, 'hotSpare': 4, 'disabled': 3, 'configurationError': 8, 'mirror': 5. |
sc2memModuleFrequency | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.14 | integer | read-only |
Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings |
sc2memModuleMaxFrequency | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.15 | integer | read-only |
Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data |
sc2memModuleVoltInterface | 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.16 | displaystring | read-only |
Memory module interface voltage interface description |
sc2cpuMultithreadEnable | 1.3.6.1.4.1.231.2.10.2.2.10.6.6 | integer | read-only |
Multithreading of CPU enabled This object is OBSOLETE for future implementations; use object 'sc2cpuMultithreadingEnabled' from 'sc2CPUTable' instead! Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3. |
sc2ComponentPowerConsumptionTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.7 | no-access |
Table of component power consumption data |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1 | no-access | |||
sc2cpcUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2cpcComponentClass | 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.2 | integer | read-only |
Component class enumeration (based on IPMI v1.0 entity ID) Enumeration: 'total-power': 224, 'cooling-device': 29, 'power-supply': 10, 'cooling-unit': 30, 'chassis': 23, 'disk-bay': 26, 'processor-module': 9, 'sub-chassis': 24, 'memory-device': 32, 'system-board': 7, 'gp': 11, 'disk': 4, 'processor': 3, 'memory-unit': 8. |
sc2cpcComponentIndex | 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.3 | integer | read-only |
Component index within class (1..n) |
sc2cpcDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.4 | displaystring | read-only |
Component designation |
sc2cpcCurrentValue | 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.5 | integer | read-only |
Current component power consumption in Watts |
sc2TrustedPlatformModuleTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.8 | no-access |
Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states) |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1 | no-access | |||
sc2tpmUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2tpmHardwareAvailable | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.2 | truefalseunknown | read-only |
TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found) |
sc2tpmBiosEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.3 | truefalseunknown | read-only |
TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value) |
sc2tpmEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.4 | truefalseunknown | read-only |
TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled) |
sc2tpmActivated | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.5 | truefalseunknown | read-only |
TPM is activated (by software; 'unknown' if hardware is not available or disabled) |
sc2tpmOwnership | 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.6 | truefalseunknown | read-only |
TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled) |
sc2PersistentMemoryModuleTable | 1.3.6.1.4.1.231.2.10.2.2.10.6.9 | no-access |
Additional information about persistent (non-volatile) memory modules to extend the sc2MemoryModuleTable. This table uses the index numbers of the previous sc2MemoryModuleTable, but only contains rows where a persistent DIMM module is detected. |
|
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1 | no-access | |||
sc2nvmemMemoryModeEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.1 | truefalseunknown | read-only |
Volatime memory mode is enabled |
sc2nvmemPersistentModeEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.2 | truefalseunknown | read-only |
Persistent memory mode is enabled |
sc2nvmemPackageSparingCapable | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.3 | truefalseunknown | read-only |
Module is capable of providing spare memory |
sc2nvmemEncryptionEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.4 | truefalseunknown | read-only |
Memory encryption is enabled |
sc2nvmemFirmwareRevision | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.5 | displaystring | read-only |
Firmware revision |
sc2nvmemTotalSize | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.6 | integer | read-only |
Total size of memory module (in GBytes; including reserved spare space) |
sc2nvmemRawCapacity | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.7 | integer | read-only |
Maximum capacity that can be allocated for use in any of the supported modes (in GBytes; excluding reserved space) |
sc2nvmemVolatileCapacity | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.8 | integer | read-only |
Capacity of volatile memory (in GBytes) |
sc2nvmemPersistentCapacity | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.9 | integer | read-only |
Capacity of persistent memory (in GBytes) |
sc2nvmemVolatilePercent | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.10 | integer | read-only |
Capacity of volatile memory (in percent of total size) |
sc2nvmemPersistentPercent | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.11 | integer | read-only |
Capacity of persistent memory (in percent of total size) |
sc2nvmemVolatileStart | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.12 | displaystring | read-only |
Start address of the volatile memory region |
sc2nvmemPersistentStart | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.13 | displaystring | read-only |
Start address of the persistent memory region |
sc2nvmemHealthStatusNonCritical | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.14 | truefalseunknown | read-only |
Non-critical (warning) status |
sc2nvmemHealthStatusCritical | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.15 | truefalseunknown | read-only |
Critical status |
sc2nvmemHealthStatusFatal | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.16 | truefalseunknown | read-only |
Fatal error status (data loss has occurred or is imminent) |
sc2nvmemPowerOnTime | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.17 | integer | read-only |
Lifetime the DIMM has been powered on (in seconds) |
sc2nvmemUpTime | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.18 | integer | read-only |
Current uptime of the DIMM for the current power cycle (in seconds) |
sc2nvmemLiftetimeRemaining | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.19 | integer | read-only |
Remaining predicted lifetime (in seconds; -1 = unknown) |
sc2nvmemAveragePowerBudget | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.20 | integer | read-only |
Average Power Budget in mW |
sc2nvmemPeakPowerBudget | 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.21 | integer | read-only |
Peak Power Budget in mW |
sc2Recovery | 1.3.6.1.4.1.231.2.10.2.2.10.7 | |||
sc2MessageLogTable | 1.3.6.1.4.1.231.2.10.2.2.10.7.1 | no-access |
Error and event message handling |
|
1.3.6.1.4.1.231.2.10.2.2.10.7.1.1 | no-access | |||
sc2msgUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2msgLogEntryNr | 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.2 | integer | read-only |
Message log entry number (index, 1..n) |
sc2msgLogEntryData | 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.3 | octet string | read-only |
Message log entry data (binary; one message per table entry) |
sc2WatchdogTable | 1.3.6.1.4.1.231.2.10.2.2.10.7.2 | no-access |
Watchdogs |
|
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1 | no-access | |||
sc2wdUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2WatchdogType | 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.2 | integer | read-only |
Watchdog type Enumeration: 'management-controller': 6, 'boot': 5, 'hardware': 2, 'bios': 4, 'other': 1, 'remote-management-controller': 7, 'cp': 8, 'software': 3. |
sc2WatchdogStatus | 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.3 | integer | read-only |
Watchdog status Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3, 'not-available': 4. |
sc2WatchdogTime | 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.4 | integer | read-only |
Watchdog timeout period in seconds (-1 = unknown) |
sc2WatchdogAction | 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.5 | integer | read-only |
Watchdog timeout action; the value unknown(1) can't be written. Not all watchdog type allow setting all of the values (-> BADVALUE). Enumeration: 'reset': 4, 'unknown': 1, 'continue': 2, 'power-cycle': 6, 'nmi': 5. |
sc2RecoverySettingTable | 1.3.6.1.4.1.231.2.10.2.2.10.7.3 | no-access |
ASR&R (Automatic server recovery and restart) settings |
|
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1 | no-access | |||
sc2asrUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2asrNrRebootRetries | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.2 | integer | read-only |
Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occured. After this number of retries the action defined in 'sc2asrRebootFailAction' will be executed (-1 = unknown, no retries). |
sc2asrDefaultRebootRetries | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.3 | integer | read-only |
Default number of retries for server failure reboot. The above object 'sc2asrNrRebootRetries' will be set to this value after the server is working properly for a certain amount of time. |
sc2asrNextBootSource | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.4 | integer | read-only |
Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI systems, load diagnostic system from alternate IDE disk). remote-disk: boot from remote network disk Enumeration: 'unknown': 1, 'remote-disk': 5, 'reserved': 3, 'operating-system': 2, 'diag-system': 4. |
sc2asrRebootFailAction | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.5 | integer | read-only |
Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero). The value no-diag-system(4) means that a diagnostics system is not available. Enumeration: 'unknown': 1, 'diag-interrupt-assert': 10, 'stop-reboot': 9, 'remote-storage': 8, 'rsb-usb': 7, 'boot-diag-system': 3, 'remote-image-disk': 5, 'no-diag-system': 4, 'switch-off': 2, 'pxe': 6. |
sc2asrRestartDelay | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.6 | integer | read-only |
Delay (in minutes) after that the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero means immediate restart (power-cycle only). Automatic restart may be disabled by setting the 'sc2asrRebootFailAction' to 'switch-off' and the 'sc2asrDefaultRebootRetries' to zero. |
sc2asrPostErrorHalt | 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.7 | integer | read-only |
Describes what to do when a POST error has occured (halt on any error, no halt on any error...). Enumeration: 'halt-on-any-error': 2, 'unknown': 1, 'other': 9, 'no-halt-on-any-error': 3. |
sc2MessageTextLogTable | 1.3.6.1.4.1.231.2.10.2.2.10.7.4 | no-access |
Error and event message handling, reported as text strings |
|
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1 | no-access | |||
sc2msgTextLogUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2msgTextLogLanguage | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.2 | integer | read-only |
Message log entry language (index, Windows language code) e.g. 1031, 1033 for German, English (default; always available) |
sc2msgTextLogSeqNr | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.3 | integer | read-only |
Message log entry sequence number (index, 1..n) |
sc2msgTextLogTimestamp | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.4 | integer | read-only |
Message log entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
sc2msgTextLogMessage | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.5 | displaystring | read-only |
Message log entry message string (multi-byte string; multi-language; not every language may be implemented) |
sc2msgTextLogErrorCode | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.6 | integer | read-only |
Message log entry error code |
sc2msgTextLogSeverity | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.7 | integer | read-only |
Message log entry severity Enumeration: 'major': 3, 'critical': 4, 'informational': 1, 'minor': 2. |
sc2msgTextLogCSSComponent | 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.8 | truefalse | read-only |
Component which caused the log message may be replaced by the customer (CSS=Customer Self Service) |
sc2MessageLogActionHintTable | 1.3.6.1.4.1.231.2.10.2.2.10.7.5 | no-access |
Action text strings for error and event messages |
|
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1 | no-access | |||
sc2mlaLanguage | 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.1 | integer | read-only |
Action text language (index, Windows language code) e.g. 1031, 1033 for German, English |
sc2mlaErrorCode | 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.2 | integer | read-only |
Action text error code (index) |
sc2mlaType | 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.3 | integer | read-only |
Message log entry severity Enumeration: 'resolution': 3, 'cause': 2, 'summary': 1. |
sc2mlaIndex | 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.4 | integer | read-only |
Action text entry string index (index, 1..n) |
sc2mlaMessage | 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.5 | displaystring | read-only |
Action message string |
sc2Status | 1.3.6.1.4.1.231.2.10.2.2.10.8 | |||
sc2AgentStatus | 1.3.6.1.4.1.231.2.10.2.2.10.8.1 | compstatus | read-only |
Overall status of all monitored components in this agent ok(1): all components are working properly; no warnings, no errors warning(2): at least one component reports a warning status or a redundant component reports an error status error(3): at least one non-redundant component reports an error status unknown(5): none of the components has a valid status (e.g. during initialization) notPresent(6): none of the components is present notManageable(7): none of the components is manageable |
sc2StatusComponentTable | 1.3.6.1.4.1.231.2.10.2.2.10.8.2 | no-access |
Table with status values of the components in this agent. The table summarizes all instances of one component to one status value. |
|
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1 | no-access | |||
sc2csUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2csStatusOverall | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.2 | compstatus | read-only |
Overall status (worst status of all components) in this unit |
sc2csStatusBoot | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.3 | compstatus | read-only |
Boot status (errors from power-on selftest and boot) |
sc2csStatusPowerSupply | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.4 | compstatus | read-only |
Power supply status |
sc2csStatusTemperature | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.5 | compstatus | read-only |
Temperature status |
sc2csStatusFans | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.6 | compstatus | read-only |
Fan status |
sc2csStatusVoltages | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.7 | compstatus | read-only |
Voltage status |
sc2csStatusCpu | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.8 | compstatus | read-only |
CPU status |
sc2csStatusMemoryModule | 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.9 | compstatus | read-only |
Memory module status |
sc2ComponentStatusSensorTable | 1.3.6.1.4.1.231.2.10.2.2.10.8.3 | no-access |
This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) information. |
|
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1 | no-access | |||
sc2cssUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2cssSensorNumber | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.2 | integer | read-only |
BMC component status sensor number (index, 1..n) |
sc2cssSensorDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.3 | displaystring | read-only |
Component status sensor designation string |
sc2cssSensorDevice | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.4 | displaystring | read-only |
Name of device (entity) the component status sensor belongs to |
sc2cssSensorDeviceInstance | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.5 | integer | read-only |
Instance number of device (entity) the component status sensor belongs to |
sc2cssSensorPhysicalLed | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.6 | truefalse | read-only |
If set, component has a physical status LED showing the sensor status |
sc2cssSensorCssComponent | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.7 | truefalse | read-only |
If set, component may be replaced by the customer (CSS 'custormer-self-service' component) |
sc2cssSensorStatus | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.8 | integer | read-only |
Status returned by the component status sensor Enumeration: 'ok': 2, 'prefailure-warning': 4, 'unknown': 1, 'failure': 5, 'identify': 3, 'not-present': 6. |
sc2cssComponentServicePartId | 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.9 | displaystring | read-only |
Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the component's designation string, with blanks substituted by underscores. |
sc2cssTableSize | 1.3.6.1.4.1.231.2.10.2.2.10.8.4 | integer | read-only |
Number of entries in the component status sensor table |
sc2Maintenance | 1.3.6.1.4.1.231.2.10.2.2.10.9 | |||
sc2MaintenanceObjectTable | 1.3.6.1.4.1.231.2.10.2.2.10.9.1 | no-access |
Table containing some other maintenance objects |
|
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1 | no-access | |||
sc2mtUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2ErrorCounterStartTime | 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.2 | integer | read-only |
Memory module error counter start time (seconds since 1/1/1970, -1 if unknown). This is the time when the error counters were started or reset last time. |
sc2SendTestTrap | 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.3 | integer | read-write |
Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by writing a non-zero value. Reading this object just returns the value 0. |
sc2AddTrapDestination | 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.4 | ipaddress | read-write |
Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of this server. |
sc2FirmwareVersionTable | 1.3.6.1.4.1.231.2.10.2.2.10.9.2 | no-access |
Controller firmware version table |
|
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1 | no-access | |||
sc2fwUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2fwType | 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.2 | integer | read-only |
Controller/firmware type Enumeration: 'bios': 1, 'management-controller': 2, 'remote-management-controller': 3. |
sc2fwModelName | 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.3 | displaystring | read-only |
Controller/firmware model name (e.g. 'Copernicus'...) |
sc2fwVersion | 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.4 | displaystring | read-only |
Controller/firmware version string (e.g. '3.81.02') |
sc2Deployment | 1.3.6.1.4.1.231.2.10.2.2.10.10 | |||
sc2DeployInfoTable | 1.3.6.1.4.1.231.2.10.2.2.10.10.1 | no-access |
Table with data of deployment information. This table is OBSOLETE (no longer used for new implementations)! |
|
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1 | no-access | |||
sc2dplInfoUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2DeployInfoChassisId | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.2 | displaystring | read-only |
Chassis serial number |
sc2DeployInfoMacAddr1 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.3 | physaddress | read-only |
MAC address 1 |
sc2DeployInfoMacAddr2 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.4 | physaddress | read-only |
MAC address 2 |
sc2DeployInfoMacAddr3 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.5 | physaddress | read-only |
MAC address 3 |
sc2DeployInfoMacAddr4 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.6 | physaddress | read-only |
MAC address 4 |
sc2DeployInfoIpAddr1 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.7 | ipaddress | read-write |
IP address 1 |
sc2DeployInfoIpAddr2 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.8 | ipaddress | read-write |
IP address 2 |
sc2DeployInfoIpAddr3 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.9 | ipaddress | read-write |
IP address 3 |
sc2DeployInfoIpAddr4 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.10 | ipaddress | read-write |
IP address 4 |
sc2DeployInfoNetMask1 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.11 | ipaddress | read-write |
IP subnet mask 1 |
sc2DeployInfoNetMask2 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.12 | ipaddress | read-write |
IP subnet mask 2 |
sc2DeployInfoNetMask3 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.13 | ipaddress | read-write |
IP subnet mask 3 |
sc2DeployInfoNetMask4 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.14 | ipaddress | read-write |
IP subnet mask 4 |
sc2DeployInfoGateway1 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.15 | ipaddress | read-write |
IP gateway 1 |
sc2DeployInfoGateway2 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.16 | ipaddress | read-write |
IP gateway 2 |
sc2DeployInfoGateway3 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.17 | ipaddress | read-write |
IP gateway 3 |
sc2DeployInfoGateway4 | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.18 | ipaddress | read-write |
IP gateway 4 |
sc2DeployInfoHostname | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.19 | displaystring | read-write |
Host name |
sc2DeployInfoMasterImageReference | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.20 | displaystring | read-write |
URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img, *.cfg, *.txt) |
sc2DeployInfoStatusOfBlade | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.21 | integer | read-write |
Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup or boot phase booting(6): ACPI OS currently booting Enumeration: 'standby': 3, 'unknown': 1, 'system-boot-failure': 4, 'power-down': 2, 'booting': 6, 'bios-setup': 5. |
sc2DeployInfoLanStatusOfSlot | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.22 | integer | read-write |
Defines wether the IP-LAN definitions are valid or not. Enumeration: 'true': 3, 'unknown': 1, 'false': 2. |
sc2DeployInfoAutomaticRecovery | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.23 | integer | read-write |
Defines if this server blade should be provided automatic recovery. Enumeration: 'true': 3, 'unknown': 1, 'false': 2. |
sc2DeployInfoStatusOfCloning | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.24 | integer | read-write |
Status of current cloning process. Enumeration: 'unknown': 1, 'cloned': 4, 'cloning': 3, 'not-cloned': 2. |
sc2DeployInfoBootMode | 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.25 | integer | read-write |
Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (for OEM systems) pxeLanx(y): boot from PXE LAN interface x (0..3) Enumeration: 'normal': 2, 'unknown': 1, 'pxeLan1': 5, 'pxeLan0': 4, 'pxeLan3': 7, 'pxeLan2': 6, 'pxeBiosSetup': 3. |
sc2OemDeployInfoTable | 1.3.6.1.4.1.231.2.10.2.2.10.10.2 | no-access |
Table with data of server OEM information. This table is OBSOLETE (no longer used for new implementations)! |
|
1.3.6.1.4.1.231.2.10.2.2.10.10.2.1 | no-access | |||
sc2odplInfoUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2odplParamId | 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.2 | integer | read-only |
OEM parameter ID (index, 1..10) |
sc2OemDeployInfoParamData | 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.3 | displaystring | read-write |
OEM parameter data |
sc2DeployLanInterfaceTable | 1.3.6.1.4.1.231.2.10.2.2.10.10.3 | no-access |
Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board interfaces are listed; no virtual interfaces. |
|
1.3.6.1.4.1.231.2.10.2.2.10.10.3.1 | no-access | |||
sc2dplLanUnitId | 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.1 | integer | read-only |
Unit identifier (index, 1..n) |
sc2dplLanInterfaceNr | 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.2 | integer | read-only |
LAN interface number (index, 1..n) |
sc2dplLanMacAddress | 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.3 | physaddress | read-only |
LAN interface hardware (MAC) address |
sc2DriverMonitoring | 1.3.6.1.4.1.231.2.10.2.2.10.11 | |||
sc2DriverMonitorComponentTable | 1.3.6.1.4.1.231.2.10.2.2.10.11.1 | no-access |
Table of components monitored by the driver monitor. Foreign index sc2uUnitId is from sc2UnitTable. |
|
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1 | no-access | |||
sc2drvmonCompClass | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.1 | integer | read-only |
Component class (index) Enumeration: 'other': 1, 'storage': 4, 'network': 3, 'software': 2. |
sc2drvmonCompIndex | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.2 | integer | read-only |
Component index (index, 1..n). This is an index over all component classes, but unit specific. |
sc2drvmonCompName | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.3 | displaystring | read-only |
Name or designation of the component |
sc2drvmonCompType | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.4 | integer | read-only |
Component (bus) type Enumeration: 'pci': 2, 'other': 1, 'usb': 3. |
sc2drvmonCompDriverName | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.5 | displaystring | read-only |
Name of the driver that created the event record |
sc2drvmonCompLocationDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.6 | displaystring | read-only |
Device location designation (if it is an adapter or other hardware component); e.g. 'PCI Slot #2' or 'IOB#1-FUNC#0' |
sc2drvmonCompLocationKey | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.7 | displaystring | read-only |
Device location key, used for identifying the component in other tables (like PCI device table); e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0' |
sc2drvmonCompStatus | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.8 | compstatus | read-only |
Status of the component; caused by specific error events, reset by corresponding 'component OK' events or by manual acknowledge |
sc2drvmonCompErrorAcknowledge | 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.9 | integer | read-write |
Acknowledge an error condition (reset error or warning status) of the component by writing a non-zero value (reading this object just returns the value 0) |
sc2DriverMonitorMessageTable | 1.3.6.1.4.1.231.2.10.2.2.10.11.2 | no-access |
Table of messages gathered by the driver monitor. The messages are based on the monitored operating system event log and are available in translated languages. Foreign indexes: sc2uUnitId is from sc2UnitTable, sc2msgTextLogLanguage from sc2MessageTextLogTable, sc2drvmonCompClass, sc2drvmonCompType and sc2drvmonCompIndex from sc2DriverMonitorComponentTable. When sc2drvmonCompIndex is 0, the event could not be assigned to any component. |
|
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1 | no-access | |||
sc2drvmonMsgSeqNr | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.1 | integer | read-only |
Driver message entry sequence number (index, 1..n) |
sc2drvmonMsgTimestamp | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.2 | integer | read-only |
Driver message entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
sc2drvmonMsgMessage | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.3 | displaystring | read-only |
Message entry string (multi-language; not every language may be implemented, then English message has to be requested) |
sc2drvmonMsgEventId | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.4 | integer | read-only |
Message entry error code (this code is a driver monitor specific error code) |
sc2drvmonMsgSeverity | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.5 | oslogseverity | read-only |
Message entry severity (may be different from original event log severity) |
sc2drvmonMsgErrorCode | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.6 | integer | read-only |
Message entry error code (must be used to get summary, causes and resolutions from sc2MessageLogActionHintTable table) |
sc2drvmonOrigLogMessage | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.7 | displaystring | read-only |
Original operating system event log / syslog entry message (only available in the server's original language or in english, depending on the driver that created that entry) |
sc2drvmonOrigLogSource | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.8 | displaystring | read-only |
Original log entry source name |
sc2drvmonOrigLogId | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.9 | integer | read-only |
Original log entry ID number (may not be available for some platforms/controllers, then ID = 0) |
sc2drvmonOrigLogSeverity | 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.10 | oslogseverity | read-only |
Original event log entry severity |
sc2drvmonTableUpdateCount | 1.3.6.1.4.1.231.2.10.2.2.10.11.3 | counter | read-only |
Counter defining the update revision of the driver monitoring tables. This counter is incremented with every change/update of the driver monitoring tables. |
sc2Notifications | 1.3.6.1.4.1.231.2.10.2.2.10.20 | |||
sc2NotificationsTrapInfo | 1.3.6.1.4.1.231.2.10.2.2.10.20.1 | |||
sc2TrapInfoServerName | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.1 | displaystring | no-access |
Name of the server the trap comes from |
sc2TrapInfoTime | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.2 | integer | no-access |
Time when the trap occured (in seconds since 01/01/1970 00:00h) |
sc2TrapInfoCabinetNr | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.3 | integer | no-access |
Cabinet number generating the trap |
sc2TrapInfoObjectDesignation | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.4 | displaystring | no-access |
Designation string for object that generated the trap (fan, temperature sensor...) |
sc2TrapInfoString | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.5 | displaystring | no-access |
Additional string to be displayed in the trap text |
sc2TrapInfoInteger | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.6 | integer | no-access |
Additional number to be displayed in the trap text |
sc2TrapInfoInteger2 | 1.3.6.1.4.1.231.2.10.2.2.10.20.1.7 | integer | no-access |
Additional number to be displayed in the trap text |
sc2TrapTest | 1.3.6.1.4.1.231.2.10.2.2.10.200.2000 |
Test trap to verify trap connection. |
||
sc2TrapCommunicationFailure | 1.3.6.1.4.1.231.2.10.2.2.10.200.2001 |
The communication with management controller failed! |
||
sc2TrapCommunicationEstablished | 1.3.6.1.4.1.231.2.10.2.2.10.200.2002 |
The communication with the management controller was reestablished |
||
sc2TrapControllerSelftestWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2003 |
Controller selftest warning. |
||
sc2TrapControllerSelftestError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2004 |
Controller selftest error. |
||
sc2TrapBiosSelftestError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2005 |
A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition. |
||
sc2TrapSevereSystemError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2006 |
The system was restarted after a severe problem. See server management message log (recovery log) for detailed information. |
||
sc2TrapFanAdded | 1.3.6.1.4.1.231.2.10.2.2.10.200.2010 |
The indicated hot-plug fan or liquid pump was inserted. |
||
sc2TrapFanRemoved | 1.3.6.1.4.1.231.2.10.2.2.10.200.2011 |
The indicated hot-plug fan or liquid pump was removed. |
||
sc2TrapFanOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2012 |
The indicated fan or liquid pump is working again. |
||
sc2TrapFanCritical | 1.3.6.1.4.1.231.2.10.2.2.10.200.2013 |
The indicated fan or liquid pump became critical |
||
sc2TrapFanFailed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2014 |
The indicated fan or liquid pump failed. |
||
sc2TrapRedundantFanFailed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2015 |
The indicated redundant fan or liquid pump failed |
||
sc2TrapTempOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2020 |
The temperature of the indicated sensor has decreased to the normal level. |
||
sc2TrapTempWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2021 |
The temperature of the indicated sensor has reached the warning level. |
||
sc2TrapTempCritical | 1.3.6.1.4.1.231.2.10.2.2.10.200.2022 |
The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled. |
||
sc2TrapTempSensorOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2023 |
The indicated broken temperature sensor is OK again. |
||
sc2TrapTempSensorBroken | 1.3.6.1.4.1.231.2.10.2.2.10.200.2024 |
The indicated temperature sensor is broken. |
||
sc2TrapPowerSupplyAdded | 1.3.6.1.4.1.231.2.10.2.2.10.200.2030 |
One hot-replace power supply was added. |
||
sc2TrapPowerSupplyRemoved | 1.3.6.1.4.1.231.2.10.2.2.10.200.2031 |
One hot-replace power supply was removed |
||
sc2TrapPowerSupplyOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2032 |
Power supply is working again. |
||
sc2TrapPowerSupplyCritical | 1.3.6.1.4.1.231.2.10.2.2.10.200.2033 |
Power supply status has become critical. |
||
sc2TrapPowerSupplyFailed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2034 |
One hot-replace power supply failed. |
||
sc2TrapRedundantPowerSupplyFailed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2035 |
One redundant hot-replace power supply failed |
||
sc2TrapPowerSupplyRedundancyLost | 1.3.6.1.4.1.231.2.10.2.2.10.200.2036 |
Power supply redundancy no longer available. |
||
sc2TrapPowerSupplyCriticalTemperature | 1.3.6.1.4.1.231.2.10.2.2.10.200.2037 |
Critical temperature in power supply. |
||
sc2TrapPowerSupplyFanFailurePrediction | 1.3.6.1.4.1.231.2.10.2.2.10.200.2038 |
Fan failure prediction in power supply. |
||
sc2TrapPowerSupplyFanFailure | 1.3.6.1.4.1.231.2.10.2.2.10.200.2039 |
Fan failure in power supply. |
||
sc2TrapAcFail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2040 |
Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap. |
||
sc2TrapDcFail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2041 |
DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs. |
||
sc2TrapOnBattery | 1.3.6.1.4.1.231.2.10.2.2.10.200.2042 |
The server is operating on battery power - by UPS or backup battery unit (BBU). |
||
sc2TrapOnMains | 1.3.6.1.4.1.231.2.10.2.2.10.200.2043 |
The mains voltage returned after a power failure. |
||
sc2TrapVoltageOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2050 |
Power supply voltage is within normal range again. |
||
sc2TrapVoltageTooLow | 1.3.6.1.4.1.231.2.10.2.2.10.200.2051 |
Power supply voltage is too low. |
||
sc2TrapVoltageTooHigh | 1.3.6.1.4.1.231.2.10.2.2.10.200.2052 |
Power supply voltage is too high. |
||
sc2TrapVoltageFailed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2053 |
Power supply voltage is out of range. |
||
sc2TrapBatteryVoltagePrefail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2054 |
Battery is predicted to fail |
||
sc2TrapCorrectableMemErrorAddr | 1.3.6.1.4.1.231.2.10.2.2.10.200.2060 |
A correctable memory error at specified address was detected. |
||
sc2TrapUncorrectableMemErrorAddr | 1.3.6.1.4.1.231.2.10.2.2.10.200.2061 |
An uncorrectable memory error at specified address was detected. |
||
sc2TrapCorrectableMemErrorBank | 1.3.6.1.4.1.231.2.10.2.2.10.200.2062 |
A correctable memory error at specified bank was detected. |
||
sc2TrapUncorrectableMemErrorBank | 1.3.6.1.4.1.231.2.10.2.2.10.200.2063 |
An uncorrectable memory error at specified bank was detected. |
||
sc2TrapCorrectableMemErrorModule | 1.3.6.1.4.1.231.2.10.2.2.10.200.2064 |
A correctable memory error at specified module was detected. |
||
sc2TrapUncorrectableMemErrorModule | 1.3.6.1.4.1.231.2.10.2.2.10.200.2065 |
An uncorrectable memory error at specified module was detected. |
||
sc2TrapCorrectableMemError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2066 |
A correctable memory error at unknown location was detected. |
||
sc2TrapUncorrectableMemError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2067 |
An uncorrectable memory error at unknown location was detected. |
||
sc2TrapMemErrorModulePrefail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2068 |
A memory module is predicted to fail (prefailure). |
||
sc2TrapMemErrorModuleFailing | 1.3.6.1.4.1.231.2.10.2.2.10.200.2069 |
A memory module is failing. |
||
sc2TrapMemErrorModuleReplaced | 1.3.6.1.4.1.231.2.10.2.2.10.200.2070 |
A memory module had failed and was replaced by a hot-spare module. |
||
sc2TrapMemErrorLoggingDisabled | 1.3.6.1.4.1.231.2.10.2.2.10.200.2071 |
Too many correctable memory errors; logging disabled. |
||
sc2TrapMemErrorLoggingEnabled | 1.3.6.1.4.1.231.2.10.2.2.10.200.2072 |
Memory errors logging enabled again. |
||
sc2TrapMemErrorAnyModuleReplaced | 1.3.6.1.4.1.231.2.10.2.2.10.200.2073 |
A memory module had failed and was replaced by a hot-spare module. |
||
sc2TrapMemErrorRedundancyLost | 1.3.6.1.4.1.231.2.10.2.2.10.200.2074 |
A memory error caused loss of memory redundancy |
||
sc2TrapMemNVDIMMLifetime | 1.3.6.1.4.1.231.2.10.2.2.10.200.2075 |
An NVDIMM memory module has reached a certain level of lifetime |
||
sc2TrapCpuSpeedChanged | 1.3.6.1.4.1.231.2.10.2.2.10.200.2080 |
This trap will be sent if the CPU clock frequency was changed because of a temperature problem. |
||
sc2TrapCpuPrefail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2081 |
A CPU is predicted to fail (prefailure). |
||
sc2TrapCpuIerr | 1.3.6.1.4.1.231.2.10.2.2.10.200.2082 |
A CPU internal error (IERR) occurred |
||
sc2TrapCpuDisabled | 1.3.6.1.4.1.231.2.10.2.2.10.200.2083 |
A CPU is disabled by BIOS |
||
sc2TrapCabinetSwitchedOff | 1.3.6.1.4.1.231.2.10.2.2.10.200.2090 |
This trap will be sent when a cabinet is switched off. For obvious reasons it cannot be sent when the main cabinet is switched off. |
||
sc2TrapCabinetSwitchedOn | 1.3.6.1.4.1.231.2.10.2.2.10.200.2091 |
This trap will be sent when a cabinet is switched on. |
||
sc2TrapPowerOffTimeReached | 1.3.6.1.4.1.231.2.10.2.2.10.200.2092 |
This trap is sent when the server is going to be switched off by schedule in some minutes. |
||
sc2TrapServerShutdown | 1.3.6.1.4.1.231.2.10.2.2.10.200.2093 |
This trap will be sent when a server is being shut down. |
||
sc2TrapShutdownCancelled | 1.3.6.1.4.1.231.2.10.2.2.10.200.2094 |
This trap will be sent if a pending server shutdown was cancelled by the user. |
||
sc2TrapBootRetryCountZero | 1.3.6.1.4.1.231.2.10.2.2.10.200.2095 |
This trap will be sent when a boot retry counter gets zero on power up. |
||
sc2TrapServerBoot | 1.3.6.1.4.1.231.2.10.2.2.10.200.2096 |
This trap will be sent when the server was booted |
||
sc2TrapServerStandby | 1.3.6.1.4.1.231.2.10.2.2.10.200.2097 |
This trap will be sent when the server entered standby mode |
||
sc2TrapServerSuspend | 1.3.6.1.4.1.231.2.10.2.2.10.200.2098 |
This trap will be sent when the server entered suspend mode |
||
sc2TrapServerResumed | 1.3.6.1.4.1.231.2.10.2.2.10.200.2099 |
This trap will be sent when the server resumed from standby or suspend mode |
||
sc2TrapMessageLogFull | 1.3.6.1.4.1.231.2.10.2.2.10.200.2100 |
The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types |
||
sc2TrapMessageLogWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2101 |
The warning threshold for the number of System Event Log entries has been exceeded. |
||
sc2TrapBootMessageLogEntry | 1.3.6.1.4.1.231.2.10.2.2.10.200.2102 |
An error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were running or any error without a specific trap. See server management message log for detailed error description. |
||
sc2TrapIntrusionAssertion | 1.3.6.1.4.1.231.2.10.2.2.10.200.2110 |
The front door or housing was opened |
||
sc2TrapIntrusionDeassertion | 1.3.6.1.4.1.231.2.10.2.2.10.200.2111 |
The front door or housing was closed |
||
sc2TrapIntrusionChanged | 1.3.6.1.4.1.231.2.10.2.2.10.200.2112 |
The front door or housing was opened or closed |
||
sc2TrapPciBusError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2113 |
PCI bus system/parity error |
||
sc2TrapPowerOnTimeReached | 1.3.6.1.4.1.231.2.10.2.2.10.200.2114 |
This trap is sent when the server is going to be switched on by schedule in some minutes. It will be sent by the Remote Management Controller. |
||
sc2TrapCssWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2120 |
Customer self service component changed to warning status |
||
sc2TrapCssFail | 1.3.6.1.4.1.231.2.10.2.2.10.200.2121 |
Customer self service component changed to fail status |
||
sc2TrapCssWarningServer | 1.3.6.1.4.1.231.2.10.2.2.10.200.2122 |
Customer self service component changed to warning status |
||
sc2TrapCssFailServer | 1.3.6.1.4.1.231.2.10.2.2.10.200.2123 |
Customer self service component changed to fail status |
||
sc2TrapPowerLimitOk | 1.3.6.1.4.1.231.2.10.2.2.10.200.2130 |
Power consumption limit changed to Ok status |
||
sc2TrapPowerLimitWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2131 |
Power consumption limit changed to warning status |
||
sc2TrapPowerLimitCritical | 1.3.6.1.4.1.231.2.10.2.2.10.200.2132 |
Power consumption limit changed to critical status |
||
sc2TrapPowerLimitDisabled | 1.3.6.1.4.1.231.2.10.2.2.10.200.2133 |
Power consumption limiting disabled |
||
sc2TrapViomInitiateCommunication | 1.3.6.1.4.1.231.2.10.2.2.10.200.2140 |
VIOM communication initiation request - VIOM manager action required. This trap is intended to signal the Virtual IO Manager that the iRMC wants to confirm the usage of the VIOM table. This trap may be repeated several times until the manager responds to the trap. |
||
sc2TrapViomStatusChanged | 1.3.6.1.4.1.231.2.10.2.2.10.200.2141 |
VIOM status has changed - VIOM manager information. If the user or a server management component deactivates VIOM, the iRMC will send a VIOM status trap. This trap will not be sent if VIOM was activated, because no user interface except the Virtual IO Manager shall be capable to enable VIOM. |
||
sc2TrapDrvMonEventMessage | 1.3.6.1.4.1.231.2.10.2.2.10.200.2150 |
Driver Monitoring detected an informational event. |
||
sc2TrapDrvMonEventWarning | 1.3.6.1.4.1.231.2.10.2.2.10.200.2151 |
Driver Monitoring detected a warning event. |
||
sc2TrapDrvMonEventError | 1.3.6.1.4.1.231.2.10.2.2.10.200.2152 |
Driver Monitoring detected an error event. |