FSC-SERVERCONTROL2-MIB: View SNMP OID List / Download MIB

VENDOR: SIEMENS


 Home MIB: FSC-SERVERCONTROL2-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 enterprises 1.3.6.1.4.1
     sni 1.3.6.1.4.1.231
             sniProductMibs 1.3.6.1.4.1.231.2
                 sniExtensions 1.3.6.1.4.1.231.2.10
                       sniServerMgmt 1.3.6.1.4.1.231.2.10.2
                           sniInventory 1.3.6.1.4.1.231.2.10.2.1
                           sniCommon 1.3.6.1.4.1.231.2.10.2.2
                               fscServerControl2 1.3.6.1.4.1.231.2.10.2.2.10
                                     sc2AgentInfo 1.3.6.1.4.1.231.2.10.2.2.10.1
                                         sc2AgentId 1.3.6.1.4.1.231.2.10.2.2.10.1.1 displaystring read-only
Agent identification string
                                         sc2AgentCompany 1.3.6.1.4.1.231.2.10.2.2.10.1.2 displaystring read-only
Agent's company name (e.g. Fujitsu Technology Solutions)
                                         sc2AgentVersion 1.3.6.1.4.1.231.2.10.2.2.10.1.3 displaystring read-only
Agent's version string (e.g. 1.05)
                                         sc2AgentBuild 1.3.6.1.4.1.231.2.10.2.2.10.1.4 displaystring read-only
Compilation time and date of agent program
                                         sc2AgentWriteAllowed 1.3.6.1.4.1.231.2.10.2.2.10.1.5 integer read-only
Defines whether writable objects can be written (except shutdown/power-off operations) Enumeration: 'unknown': 1, 'write-not-allowed': 2, 'write-allowed': 3.
                                         sc2AgentShutdownAllowed 1.3.6.1.4.1.231.2.10.2.2.10.1.6 integer read-only
Defines whether shutdown/power-off objects can be written Enumeration: 'unknown': 1, 'shutdown-not-allowed': 2, 'shutdown-allowed': 3.
                                     sc2UnitInformation 1.3.6.1.4.1.231.2.10.2.2.10.2
                                         sc2LocalServerUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.1 integer read-only
Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the sc2Units table.
                                         sc2NumberUnits 1.3.6.1.4.1.231.2.10.2.2.10.2.2 integer read-only
Number of available units (size of sc2Units table).
                                         sc2UnitTable 1.3.6.1.4.1.231.2.10.2.2.10.2.3 no-access
Description of all units in this MIB
                                             sc2Units 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1 no-access
                                                 sc2uUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2UnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.2 unitclass read-only
Unit classification (type)
                                                 sc2UnitCabinetNr 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.3 integer read-only
Unit cabinet number (used for addressing storage extension cabinets or server blades). The ID of the local server is usually 0.
                                                 sc2UnitDesignation 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.4 displaystring read-only
Unit designation / housing type (e.g. 'H200R')
                                                 sc2UnitModelName 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.5 displaystring read-only
Unit model name (e.g. 'PRIMERGY RX100')
                                                 sc2UnitManufacturer 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.6 displaystring read-only
Unit manufacturer name (e.g. 'Fujitsu Technology Solutions')
                                                 sc2UnitSerialNumber 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.7 displaystring read-only
Unit serial number (e.g. 'YBCL123456')
                                                 sc2UnitLocation 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.8 displaystring read-only
Unit location string (e.g. 'ServerCenter Room 17, Rack 9')
                                                 sc2UnitContact 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.9 displaystring read-only
Unit contact name (e.g. 'Mr. Bond')
                                                 sc2UnitAdminURL 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.10 displaystring read-only
URL of administration HTML interface (e.g. 'http://MyServer/admin')
                                                 sc2FrontDoorStatus 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.11 integer read-only
Status describing whether the front door is open or closed Enumeration: 'unknown': 1, 'open': 2, 'closed': 3.
                                                 sc2HousingOpenStatus 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.12 integer read-only
Status describing whether the housing is open or closed Enumeration: 'unknown': 1, 'open': 2, 'closed': 3, 'opened-and-closed': 4.
                                                 sc2MsgLogLanguages 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.13 displaystring read-only
Supported languages of text message log (comma-seperated list of decimal language codes, see sc2MessageTextLogTable). e.g. '1031,1033' means German and English are supported. English (1033) is the default language and is always available.
                                                 sc2UnitWorldWideName 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.14 displaystring read-only
Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB')
                                                 sc2RemcsId 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.15 displaystring read-only
REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number
                                                 sc2AssetTag 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.16 displaystring read-only
Customer specific asset tag (40 bytes)
                                                 sc2MsgLogAvailable 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.17 truefalse read-only
Replies whether a message log is available on this unit
                                                 sc2ManagementIpAddress 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.18 displaystring read-only
IPv4 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv4 address string).
                                                 sc2HasUefiFirmware 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.19 truefalse read-only
Replies whether the system is equipped with UEFI firmware
                                                 sc2ManagementIpAddressV6 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.20 displaystring read-only
IPv6 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv6 address string).
                                         sc2UnitTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.2.4 counter read-only
Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update.
                                         sc2UnitParentTable 1.3.6.1.4.1.231.2.10.2.2.10.2.5 no-access
Parent-child relationship of all units: list the parent of all available units. Only units that have a parent are listed in this table.
                                             sc2UnitParents 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1 no-access
                                                 sc2pUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2ParentUnit 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.2 integer read-only
Unit identifier of this unit's parent
                                                 sc2ParentUnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.3 unitclass read-only
Parent unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
                                         sc2UnitChildTable 1.3.6.1.4.1.231.2.10.2.2.10.2.6 no-access
Parent-child relationship of all units: list all children of all available units. Only units that have children are listed in this table.
                                             sc2UnitChilds 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1 no-access
                                                 sc2cUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2cChildNr 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.2 integer read-only
Child number (index, 1..n)
                                                 sc2ChildUnit 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.3 integer read-only
Child unit
                                                 sc2ChildUnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.4 unitclass read-only
Unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
                                     sc2Management 1.3.6.1.4.1.231.2.10.2.2.10.3
                                         sc2ManagementNodeTable 1.3.6.1.4.1.231.2.10.2.2.10.3.1 no-access
SNMP management node addresses (how to address the units)
                                             sc2ManagementNodes 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1 no-access
                                                 sc2mnUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2mnNodeNr 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.2 integer read-only
Management node address number (index, 1..n)
                                                 sc2UnitNodeIfType 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.3 integer read-only
Management node interface type Enumeration: 'unknown': 1, 'ipx': 3, 'ip-v6': 4, 'ip': 2.
                                                 sc2UnitNodeAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.4 displaystring read-only
Management node address (e.g. 192.168.0.100)
                                                 sc2UnitNodeIpNetmask 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.5 displaystring read-only
Management node address (e.g. 255.255.255.128)
                                                 sc2UnitNodeGateway 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.6 displaystring read-only
Management node address (e.g. 192.168.0.126)
                                                 sc2UnitNodeName 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.7 displaystring read-only
Management node name (DNS name, e.g. apollo.ts.fujitsu.com)
                                                 sc2UnitNodeClass 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.8 integer read-only
Management node class: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interface (in a blade server chassis) secondary-remote: remote management controller (in an RSB concentrator environment) secondary-remote-backup: backup remote management controller baseboard-controller: local baseboard management controller (BMC) Enumeration: 'unknown': 1, 'secondary-remote-backup': 6, 'primary': 2, 'management-blade': 4, 'secondary-remote': 5, 'baseboard-controller': 7, 'secondary': 3.
                                                 sc2UnitNodeMacAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.9 physaddress read-only
Management node hardware (MAC) address
                                                 sc2UnitNodeUseDHCP 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.10 integer read-only
Management node uses DHCP to obtain its address Enumeration: 'unknown': 1, 'use-fixed-address': 2, 'use-dhcp': 3.
                                                 sc2UnitNodeControllerType 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.11 displaystring read-only
The type of the remote management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once.
                                                 sc2UnitNodeControllerModel 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.12 displaystring read-only
The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used for identification, only for displaying (can be changed in different firmware versions)!
                                                 sc2UnitNodeControllerFWVersion 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.13 displaystring read-only
The FW version of the remote management controller
                                                 sc2UnitNodeControllerStorage 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.14 integer read-only
Status of the controller specific external storage used for the system management. Enumeration: 'not-available': 2, 'unknown': 1, 'available-sdcard': 3.
                                                 sc2UnitNodeSNMPEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.15 truefalseunknown read-only
SNMP interface is enabled at management node
                                                 sc2UnitNodeCIMEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.16 truefalseunknown read-only
CIM protocol is enabled at management node
                                                 sc2UnitNodeRemoteIPMIEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.17 truefalseunknown read-only
Remote IPMI is enabled at management node
                                         sc2NodeTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.3.2 counter read-only
Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update.
                                         sc2ManagementChannelType 1.3.6.1.4.1.231.2.10.2.2.10.3.3 integer read-only
The type of the management channel currently used (this MIB instance). Enumeration: 'unknown': 1, 'primary': 2, 'secondary': 3.
                                         sc2ManagementProcessorTable 1.3.6.1.4.1.231.2.10.2.2.10.3.4 no-access
System management service processors
                                             sc2ManagementProcessors 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1 no-access
                                                 sc2spUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2spProcessorNr 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.2 integer read-only
Service processor number (index, 1..n)
                                                 sc2spModelName 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.3 displaystring read-only
Service processor model name
                                                 sc2spFirmwareVersion 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.4 displaystring read-only
Service processor firmware version / revision
                                                 sc2spBatteryStatus 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.5 integer read-only
Service processor backup battery status Enumeration: 'discharging': 7, 'ok': 3, 'unknown': 1, 'recharging': 5, 'failed': 6, 'not-present': 2, 'on-battery': 4.
                                                 sc2spBatteryDischargeTime 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.6 integer read-only
Maximum time (in seconds) this backup battery can discharged, after that a shutdown will be performed (-1 = unknown)
                                                 sc2spTimeOnBattery 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.7 counter read-only
Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery)
                                                 sc2spDoBatteryChargeCycle 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.8 integer read-write
Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0.
                                                 sc2spBatteryChargeLevel 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.9 gauge read-only
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity).
                                         sc2ManagedUpsNodeTable 1.3.6.1.4.1.231.2.10.2.2.10.3.5 no-access
UPS nodes managed by the units
                                             sc2ManagedUpsNodes 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1 no-access
                                                 sc2upsUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2upsNr 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.2 integer read-only
UPS number (index, 1..n)
                                                 sc2upsVendorName 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.3 displaystring read-only
UPS vendor name
                                                 sc2upsModelName 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.4 displaystring read-only
UPS model name
                                                 sc2upsMgmtAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.5 displaystring read-only
UPS management interface target address (represented as string; may contain an IP V4 address, IP V6 address or a URL)
                                                 sc2upsMibRoot 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.6 displaystring read-only
UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available)
                                                 sc2upsSnmpCommunity 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.7 displaystring read-only
UPS SNMP community name (empty string if no SNMP agent available)
                                         sc2UpsNodeTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.3.6 counter read-only
Counter defining the update revision of the UPS node table. This counter is incremented with every table contents change/update.
                                     sc2ServerInformation 1.3.6.1.4.1.231.2.10.2.2.10.4
                                         sc2ServerTable 1.3.6.1.4.1.231.2.10.2.2.10.4.1 no-access
Table containing information about the available servers
                                             sc2Servers 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1 no-access
                                                 sc2srvUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2srvPhysicalMemory 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.2 integer read-only
Size of physical main memory installed (MBytes)
                                                 sc2srvLastBootResult 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.3 integer read-only
Result of last system boot Enumeration: 'no-boot-cp': 4, 'diagnostic-boot-failed': 7, 'os-boot-successful': 2, 'unknown': 1, 'diagnostic-boot-successful': 3, 'hardware-failure': 8, 'no-bootable-media': 5, 'os-failed-to-load': 6.
                                                 sc2srvCurrentBootStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.4 integer read-only
Status of the current boot Enumeration: 'no-boot-cp': 3, 'reset': 12, 'os-shutdown': 10, 'off': 2, 'unknown': 1, 'setup': 5, 'diagnostic-shutdown': 11, 'os-boot': 6, 'os-running': 8, 'diagnostic-boot': 7, 'self-test': 4, 'diagnostic-running': 9.
                                                 sc2srvShutdownCommand 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.5 integer read-write
Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; when reading that value, always unknown(1) is replied; argument tells what kind of action: power-on: switch power on power-off: switch power off power-cycle: switch power off and switch power on again. shutdown-and-off: execute a shutdown then power off shutdown-and-reset: execute a shutdown then reset shutdown-and-power-cycle: execute a shutdown then power off and on again raise-nmi: raise an NMI (normally causes debugger to start) reset: execute a reset (without shutdown) The value unknown(1) cannot be set. Enumeration: 'reset': 10, 'power-off': 2, 'unknown': 1, 'raise-nmi': 8, 'power-on': 3, 'shutdown-and-off': 5, 'shutdown-and-reset': 6, 'abort-pending-command': 9, 'shutdown-and-power-cycle': 7, 'power-cycle': 4.
                                                 sc2srvShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.6 integer read-write
Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action, no delay -1 = unknown (delay not supported) The value unknown(-1) cannot be set.
                                                 sc2srvUUID 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.7 displaystring read-only
Universal Unique ID (UUID) number (as specified in RFC 4122; shown in network byte order, big-endian) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '33221100-5544-7766-8899-AABBCCDDEEFF'
                                                 sc2srvPhysicalMemoryOs 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.8 integer read-only
Size of physical main memory available to the operating system (MBytes). This value is similar to 'sc2srvPhysicalMemory', but may be less if the system has mirror or hot spare memory modules.
                                                 sc2srvUUIDWireFormat 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.9 displaystring read-only
Universal Unique ID (UUID) number (shown in the wire format; little-endian for the first three fields, as consistently used in the PC industry) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '00112233-4455-6677-8899-AABBCCDDEEFF'
                                                 sc2srvOsPlatform 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.10 integer read-only
Reports about the current operating system platform (x86, x64) Enumeration: 'intel-x86': 2, 'other': 1, 'intel-x64': 3.
                                                 sc2srvBiosVersion 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.11 displaystring read-only
System BIOS version
                                                 sc2srvHasEncryptedPartitions 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.12 truefalseunknown read-only
Specifies whether encrypted file systems (e.g. by Windows BitLocker) are used (may prevent from BIOS updates)
                                                 sc2srvTrustedExecutionTechnologyEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.13 truefalseunknown read-only
Specifies whether Intel Trusted Execution Technology (TXT) is enabled (may prevent from BIOS updates)
                                         sc2UnitPowerOnOffTable 1.3.6.1.4.1.231.2.10.2.2.10.4.2 no-access
Unit power-on and -off information
                                             sc2UnitPowerOnOff 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1 no-access
                                                 sc2ooUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2PowerOnOffStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.2 integer read-only
Current power on/off status Enumeration: 'unknown': 1, 'off': 2, 'on': 3.
                                                 sc2LastPowerOffSource 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.3 integer read-only
Reason why the system was switched off last time Enumeration: 'remote-off': 11, 'fan-fail': 6, 'repeated-fan-fail': 40, 'viom-inventory-board': 38, 'power-limiting': 35, 'watchdog-power-cycle': 37, 'temperature-damage': 8, 'keyboard': 29, 'watchdog': 10, 'power-supply-failure': 9, 'power-button': 3, 'ac-fail': 4, 'clock': 5, 'swoff-command': 2, 'unknown': 1, 'temperature-critical': 7, 'warmstart': 24, 'power-cycle': 33, 'reset-button': 25, 'repeated-temperature-critical': 41, 'viom-init-boot': 39, 'firmware-restart': 242, 'cpu-error': 14, 'remote-manager-reset': 32, 'hardware-reset': 23, 'nmi': 20, 'mmb-continuous-operation': 36, 'peripheral-bus-error': 13, 'remote-manager': 31, 'hardware-fail': 12, 'ac-fail-reboot': 26, 'housing-opened': 243.
                                                 sc2LastPowerOnSource 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.4 integer read-only
Source the system was switched on from Enumeration: 'fan-fail': 6, 'chipcard-reader': 30, 'temperature-damage': 8, 'keyboard': 29, 'watchdog': 10, 'power-supply-failure': 9, 'power-button': 3, 'ac-fail': 4, 'clock': 5, 'swoff-command': 2, 'unknown': 1, 'mgmt-processor-fail': 27, 'temperature-critical': 7, 'warmstart': 24, 'power-cycle': 33, 'reset-button': 25, 'viom-init-boot': 39, 'pci-pme': 28, 'remote-on': 11, 'firmware-restart': 242, 'cpu-error': 14, 'viom-inventory-board': 38, 'remote-manager-reset': 32, 'hardware-reset': 23, 'nmi': 20, 'peripheral-bus-error': 13, 'remote-manager': 31, 'housing-closed': 243, 'hardware-fail': 12, 'ac-fail-reboot': 26.
                                                 sc2LastPowerOnTime 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.5 integer read-only
Time and date (UTC) the system was booted (seconds since 1/1/1970; 0 = unknown or not available)
                                                 sc2PowerOnCounts 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.6 integer read-only
Tells how often the server was switched on in its life (0 = unknown or not available)
                                                 sc2PowerOnDuration 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.7 integer read-only
Tells how long the system has stayed ON in its life (in seconds; 0 = unknown or not available)
                                                 sc2PowerOffDuration 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.8 integer read-only
Tells how long the system has stayed OFF in its life (in seconds; 0 = unknown or not available)
                                                 sc2PowerFailRecovery 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.9 integer read-only
Action on AC power recovery after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-available': 2, 'unknown': 1, 'remain-off': 4, 'switch-on': 5, 'as-before': 3.
                                                 sc2PowerCommand 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.10 integer read-write
Switch the unit on or off; mainly used for extension cabinets; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again No graceful system shutdown is performed - use sc2srvShutdownCommand if shutdown of a server is requested! The value unknown(1) cannot be set and will be delivered if the object is read. Enumeration: 'unknown': 1, 'off': 2, 'power-cycle': 4, 'on': 3.
                                                 sc2PowerSupplyRedundancy 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.11 truefalseunknown read-only
Specifies whether the power supply system contains redundant power supplies and whether redundancy is available
                                                 sc2PowerSupplyMatchStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.12 integer read-only
Status of power supply matching - 'ok' if power supplies do not mismatch Enumeration: 'mismatch': 3, 'unknown': 1, 'ok': 2.
                                         sc2PerformanceTable 1.3.6.1.4.1.231.2.10.2.2.10.4.3 no-access
Server performance and utilisation information (Obsolete! Please use sc2PerformanceValueTable!)
                                             sc2Performance 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1 no-access
                                                 sc2perfUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2perfNr 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.2 integer read-only
Server performance entry number (index, 1..n)
                                                 sc2PerformanceType 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.3 integer read-only
Server performance object type (description see below) Enumeration: 'memory-physical': 6, 'memory-percent': 8, 'pci-transfer': 5, 'cp': 1, 'memory-total': 7, 'pci-efficiency': 4, 'cpu-overall': 2, 'pci-load': 3.
                                                 sc2PerformanceObjectNr 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.4 integer read-only
Server performance object number (0..n; for types with multiple objects)
                                                 sc2PerformanceName 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.5 displaystring read-only
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
                                                 sc2PerformanceValue 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.6 gauge read-only
Server performance value (value interpretation depending on type; 0xffffffff = unknown): cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in percent pci-load: PCI bus load in percent pci-efficiency: PCI bus efficiency in percent (100% is optimum) pci-transfer: PCI bus transfer rate in MBytes/sec. memory-physical: Physical memory usage in MBytes memory-total: Total memory usage (physical + virtual) in MBytes memory-percent: Physical memory usage in percent
                                         sc2TimerOnOffTable 1.3.6.1.4.1.231.2.10.2.2.10.4.4 no-access
Power on/off timer table
                                             sc2TimerOnOff 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1 no-access
                                                 sc2tooUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2tooDayOfWeek 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.2 integer read-only
Day of the week the times should act upon (index); 1=Sunday, 2=Monday...
                                                 sc2OnTime 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.3 integer read-write
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
                                                 sc2OffTime 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.4 integer read-write
Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
                                         sc2PowerMonitoringTable 1.3.6.1.4.1.231.2.10.2.2.10.4.5 no-access
Power monitoring table
                                             sc2PowerMonitoring 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1 no-access
                                                 sc2pmUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2pmCurrentPowerMonitoringAvailable 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.2 truefalse read-only
Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not available
                                                 sc2pmCurrentPowerMonitoringEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.3 truefalse read-only
Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available
                                                 sc2pmNominalPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.4 integer read-only
Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available)
                                                 sc2pmCurrentPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.5 gauge read-only
Current value of the system's power consumption (in Watts; -1 if value not available)
                                                 sc2pmCurrentPowerControl 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.6 integer read-only
Power mode control value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise Enumeration: 'limited': 7, 'minimum-power': 4, 'unknown': 1, 'low-noise': 8, 'best-performance': 3, 'disabled': 2, 'automatic': 5.
                                                 sc2pmPowerLimitStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.7 integer read-only
Power limitation status (valid if power control = limited) ok: power consumption is within specified range warning: power consumption is above warning threshold (sc2pmPowerLimitWarning) but below limit error: power consumption is above limit (sc2pmPowerLimitThreshold) disabled: power consumption limiting is disabled Enumeration: 'disabled': 5, 'unknown': 1, 'warning': 3, 'ok': 2, 'error': 4.
                                                 sc2pmPowerLimitThreshold 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.8 integer read-only
Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled)
                                                 sc2pmPowerLimitWarning 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.9 integer read-only
Warning limit level (in percent of the maximum limit threshold; 0 if value not available; only valid if limiting enabled)
                                                 sc2pmRedundancyCritLevel 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.10 integer read-only
Upper critical power consumption level (in Watts; -1 if value not available); power supply redundancy lost if level is exceeded
                                                 sc2pmPowerControlMode 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.11 integer read-only
Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise Enumeration: 'scheduled': 6, 'minimum-power': 4, 'limited': 7, 'unknown': 1, 'low-noise': 8, 'best-performance': 3, 'disabled': 2, 'automatic': 5.
                                                 sc2pmPowerDisplayUnit 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.12 integer read-only
Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed in Btu Enumeration: 'watt': 2, 'unknown': 1, 'bt': 3.
                                         sc2UtilizationHistoryTable 1.3.6.1.4.1.231.2.10.2.2.10.4.6 no-access
Utilization history table (for power consumption); table only contains existing values (no values for non-existing values)
                                             sc2UtilizationHistory 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1 no-access
                                                 sc2uthUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2uthEntity 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.2 integer read-only
Utilization value entity; describes what kind of value to be requested: powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) per minute powerConsumptionMonth: power consumption values of the last month; one value (Watts) per hour powerConsumptionYear: power consumption values of the last year; one value (Watts) per day Enumeration: 'powerConsumptionYear': 3, 'powerConsumptionDay': 1, 'powerConsumptionMonth': 2.
                                                 sc2uthTimeStamp 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.3 integer read-only
Time stamp of the currenty history entry (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
                                                 sc2uthHardwareUUID 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.4 displaystring read-only
UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade environments)
                                                 sc2uthAverageValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.5 gauge read-only
Average value (in Watts) within the monitored time period (minute, hour, day)
                                                 sc2uthMinValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.6 gauge read-only
Minimum (lowest) value within the monitored time period
                                                 sc2uthMaxValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.7 gauge read-only
Maximum (highest) value within the monitored time period
                                         sc2PowerSourceInformationTable 1.3.6.1.4.1.231.2.10.2.2.10.4.7 no-access
Power source information table
                                             sc2PowerSourceInformation 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1 no-access
                                                 sc2psiUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2psiPowerSourceType 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.2 displaystring read-only
System input power source type (e.g. 'AC', 'DC')
                                                 sc2psiPowerSourcePhase 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.3 integer read-only
System input phase of power source. Enumeration: 'unknown': 1, 'three-phase': 3, 'single-phase': 2.
                                                 sc2psiPowerSourceVoltage 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.4 integer read-only
System nominal input voltage of power source (in Volts; -1 if value not available).
                                         sc2VirtualIoManagerTable 1.3.6.1.4.1.231.2.10.2.2.10.4.8 no-access
Virtual I/O Manager (VIOM) information table
                                             sc2VirtualIoManager 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1 no-access
                                                 sc2viomUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2viomCurrentManagerId 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.2 displaystring read-only
Identification string of the VIOM manager that currently manages this server
                                                 sc2viomEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.3 truefalseunknown read-only
True if the server is enabled for VIOM
                                                 sc2viomBiosSupport 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.4 truefalseunknown read-only
True if the BIOS supports VIOM
                                                 sc2viomConnectionStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.5 integer read-only
The connection status for VIOM - bit field: Bit 0 - waiting for VIOM table Bit 1 - waiting for inventory table Bit 2 - waiting for external power-on event
                                         sc2PowerSupplyRedundancyConfigurationTable 1.3.6.1.4.1.231.2.10.2.2.10.4.9 no-access
Power Supply redundancy configuration table
                                             sc2PowerSupplyRedundancyConfiguration 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1 no-access
                                                 sc2PSRedUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2PSRedundancyMode 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.2 integer read-only
Configured power supply redundancy mode; configured in Server Configuration Enumeration: 'psu-redundancy': 4, 'triple-ac-redundancy': 34, 'unknown': 1, 'dual-ac-redundancy': 18, 'no-redundancy': 3, 'not-specified': 2.
                                                 sc2PSRedundancyModeConfig 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.3 integer read-only
Configuration of number required power supplies for the different redundancy modes specified in sc2PSRedundancyMode: no-redundancy(2): no redundancy required redundancy-1-1(19): 1 required + 1 spare PSU (psu-redundancy mode) or 1 PSU per AC phase (dual-ac-redundancy mode) redundancy-2-1(35): 2 required + 1 spare PSU (psu-redundancy mode) redundancy-3-1(51): 3 required + 1 spare PSU (psu-redundancy mode) redundancy-2-2(36): 2 PSUs per AC phase (dual-ac-redundancy mode) Enumeration: 'redundancy-1-1': 19, 'redundancy-3-1': 51, 'redundancy-2-1': 35, 'unknown': 1, 'redundancy-2-2': 36, 'no-redundancy': 2.
                                                 sc2PSRedundancyRequiredPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.4 integer read-only
Number of power supplies required for configured redundancy mode
                                                 sc2PSRedundancyPopulatedPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.5 integer read-only
Number of power supplies populated for configured redundancy mode
                                                 sc2PSRedundancyConfigurationStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.6 compstatus read-only
Status of the redundancy configuration; reports the status about whether enough power supplies are installed to operate at the configured redundancy mode
                                                 sc2PSRedundancyThresholdStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.7 compstatus read-only
Status of redundancy threshold; reports the status about whether the actual power consumption exceeds the maximum power consumption level for the configured redundancy mode.
                                                 sc2PSRedundancyStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.8 integer read-only
Status of power supply redundancy; similar to sc2PowerSupplyRedundancy, but with additional status evaluation according to the power supply redundancy configuration. not-available(2): redundancy not required and not available (no error) ok(3): redundancy required and available warning(4): redundancy required but not available error(5): redundancy required but severe problem detected Enumeration: 'not-available': 2, 'unknown': 1, 'warning': 4, 'ok': 3, 'error': 5.
                                         sc2PerformanceValueTable 1.3.6.1.4.1.231.2.10.2.2.10.4.10 no-access
Server performance and utilisation values
                                               sc2PerformanceValues 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1 no-access
                                                   sc2PerfValUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.1 integer read-only
Unit identifier (index, 1..n). For performacne values on local system use 1!
                                                   sc2PerfValType 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.2 integer read-only
Server performance object type (description see below) Enumeration: 'logicalCpuUsagePercent': 6, 'totalMemoryUsagePercent': 4, 'physicalMemoryUsagePercent': 2, 'totalMemoryUsageMb': 3, 'overallCpuUsagePercent': 5, 'physicalMemoryUsageMb': 1.
                                                   sc2PerfValObjectNr 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.3 integer read-only
Server performance object number (1..n; for types with multiple objects)
                                                   sc2PerfValName 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.4 displaystring read-only
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
                                                   sc2PerfValCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.5 gauge read-only
Server performance value (value interpretation depending on type; 0xffffffff = unknown): physicalMemoryUsageMb: Physical memory usage in MBytes physicalMemoryUsagePercent: Physical memory usage in percent totalMemoryUsageMb: Total memory usage (physical + virtual) in MBytes totalMemoryUsagePercent: Total memory usage (physical + virtual) in percent overallCpuUsagePercent: Overall CPU load in percent logicalCpuUsagePercent: Load of a single CPU in percent
                                     sc2Environment 1.3.6.1.4.1.231.2.10.2.2.10.5
                                         sc2TemperatureSensorTable 1.3.6.1.4.1.231.2.10.2.2.10.5.1 no-access
Temperature sensors
                                             sc2TemperatureSensors 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1 no-access
                                                 sc2tempUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2tempSensorNr 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.2 integer read-only
Temperature sensor number (index, 1..n)
                                                 sc2tempSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.3 displaystring read-only
Temperature sensor designation (e.g. TEMP-PS1)
                                                 sc2tempSensorIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4 displaystring read-only
Temperature sensor identification string (e.g. TEMP-RSB1)
                                                 sc2tempSensorStatus 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5 integer read-only
Status of the temperature sensor Enumeration: 'not-available': 2, 'ok': 3, 'sensor-failed': 4, 'temperature-warning': 9, 'temperature-critical-toohot': 7, 'unknown': 1, 'failed': 5, 'temperature-warning-toohot': 6, 'temperature-normal': 8.
                                                 sc2tempCurrentTemperature 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6 gauge read-only
Current temperature at this sensor (degrees Celsius; 0 if unknown or sensor failed)
                                                 sc2tempWarningLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7 integer read-only
Maximum temperature - warning level (degrees Celsius; 0 if unknown or undefined)
                                                 sc2tempCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8 integer read-only
Maximum temperature - critical level (degrees Celsius; 0 if unknown or undefined), system shutdown may occur if this level is exceeded
                                                 sc2tempCriticalReaction 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9 integer read-write
Reaction if temperature exceeds the critical level (the value unknown(1) cannot be set) Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2.
                                         sc2FanTable 1.3.6.1.4.1.231.2.10.2.2.10.5.2 no-access
Cooling devices (fans, liquid cooling pumps)
                                             sc2Fans 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1 no-access
                                                 sc2fanUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2fanNr 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.2 integer read-only
Cooling device number (index, 1..n)
                                                 sc2fanDesignation 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3 displaystring read-only
Cooling device designation (e.g. FAN-PS1)
                                                 sc2fanIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.4 displaystring read-only
Cooling device identification string (e.g. FAN-1-POWERSUPPLY)
                                                 sc2fanStatus 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5 integer read-only
Status of the cooling device Enumeration: 'redundant-fan-failed': 6, 'ok': 3, 'prefailure-predicted': 5, 'unknown': 1, 'disabled': 2, 'failed': 4, 'not-manageable': 7, 'not-present': 8.
                                                 sc2fanCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6 gauge read-only
Current cooling device speed (revolutions per minute; 0 if unknown or failed)
                                                 sc2fanQuality 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.7 gauge read-only
Quality of cooling device (in percent of nominal speed - measured at full speed)
                                                 sc2fanFailReaction 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.8 integer read-write
Reaction if the cooling device fails (the value unknown(1) cannot be set) Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2.
                                                 sc2fanFailShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.9 integer read-write
Delay time (in seconds) when shutdown should commit on cooling device fail (if shutdown-and-off is configured; 0 = immediately, -1 = unknown, cannot be set)
                                                 sc2fanCoolingDeviceType 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.10 integer read-only
Type of cooling device (whether fan or liquid cooling pump) fan(2): fan liquid(3): liquid cooling pump Enumeration: 'unknown': 1, 'fan': 2, 'liquid': 3.
                                         sc2AirflowTable 1.3.6.1.4.1.231.2.10.2.2.10.5.3 no-access
Exhaust airflow volume table
                                             sc2Airflow 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1 no-access
                                                 sc2afUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2afExhaustAirflowVolume 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.2 integer read-only
System exhaust airflow volume ('-1' if value not available)
                                                 sc2afExhaustAirflowVolumeUnit 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.3 displaystring read-only
System exhaust airflow volume unit (e.g. 'cbm/h', 'ccm/min', ...)
                                     sc2Hardware 1.3.6.1.4.1.231.2.10.2.2.10.6
                                         sc2SystemBoardTable 1.3.6.1.4.1.231.2.10.2.2.10.6.1 no-access
System board (main board) information
                                             sc2SystemBoard 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1 no-access
                                                 sc2sbUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2sbBoardNr 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.2 integer read-only
System board number (index, 1..n)
                                                 sc2SystemBoardModelName 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.3 displaystring read-only
Model name (e.g. 'D1297')
                                                 sc2SystemBoardProductNumber 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.4 displaystring read-only
Product number (may be identical to ModelName)
                                                 sc2SystemBoardRevision 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.5 displaystring read-only
Revision string (e.g. 'WGS1 GS3')
                                                 sc2SystemBoardSerialNumber 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.6 displaystring read-only
Serial number (not available for all boards)
                                                 sc2SystemBoardDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.7 displaystring read-only
Designation (important when multiple system boards are available)
                                                 sc2SystemBoardSDCardSlotPresent 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.8 truefalseunknown read-only
System board contains SD card slot
                                         sc2PowerSupplyTable 1.3.6.1.4.1.231.2.10.2.2.10.6.2 no-access
Power supplies
                                             sc2PowerSupply 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1 no-access
                                                 sc2psUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2psPowerSupplyNr 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.2 integer read-only
Power supply (bay) number (index, 1..n)
                                                 sc2PowerSupplyDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.3 displaystring read-only
Power supply designation (e.g. PS1)
                                                 sc2PowerSupplyIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4 displaystring read-only
Power supply identification string (e.g. PS1)
                                                 sc2PowerSupplyStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5 integer read-only
Power supply status Enumeration: 'not-manageable': 8, 'ok': 3, 'fan-failure': 10, 'ac-fail': 5, 'unknown': 1, 'non-redundant-ac-fail': 13, 'critical-temperature': 7, 'non-redundant-dc-fail': 12, 'failed': 4, 'not-present': 2, 'power-safe-mode': 11, 'dc-fail': 6, 'fan-failure-predicted': 9.
                                                 sc2psPowerSupplyLoad 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.6 integer read-only
Actual power supply output load in Watts (0 = not available)
                                                 sc2psPowerSupplyNominal 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.7 integer read-only
Nominal power supply output load in Watts (0 = not available), the maximum value the power supply can provide
                                         sc2VoltageTable 1.3.6.1.4.1.231.2.10.2.2.10.6.3 no-access
Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown)
                                             sc2Voltages 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1 no-access
                                                 sc2voUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2voSensorNr 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.2 integer read-only
Voltage sensor number (index, 1..n)
                                                 sc2VoltageDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3 displaystring read-only
Voltage designation string (e.g. 12V, 3V3, ...)
                                                 sc2VoltageStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4 integer read-only
Voltage status not-available(2): no voltage available (e.g. CPU voltage on empty CPU socket) ok(3): voltage value is in normal range too-low(4): voltage value is below nominal range too-high(5): voltage value is above upper limit out-of-range(6): voltage value is out of normal range (cannot detect whether too low or too high) warning(7): voltage warning (e.g. battery failure predicted) Enumeration: 'not-available': 2, 'ok': 3, 'unknown': 1, 'out-of-range': 6, 'warning': 7, 'too-low': 4, 'too-high': 5.
                                                 sc2VoltageCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.5 gauge read-only
Voltage current value (in mV; 0xFFFFFFFF = unknown; negative voltages are reported as negative values: -1770 (0xFFFFF916) means -1.77 Volts)
                                                 sc2VoltageNominalValue 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.6 integer read-only
Voltage nominal value (in mV; -1 = unknown; negative voltages are reported as negative values)
                                                 sc2VoltageMinimumLevel 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.7 integer read-only
Voltage minimum level (in mV; -1 = unknown; negative voltages are reported as negative values)
                                                 sc2VoltageMaximumLevel 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.8 integer read-only
Voltage maximum level (in mV; -1 = unknown; negative voltages are reported as negative values)
                                                 sc2VoltageCurrentLoad 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.9 gauge read-only
Current output load on this voltage line, in percent of the maximum load (0xFFFFFFFF = unknown)
                                         sc2CPUTable 1.3.6.1.4.1.231.2.10.2.2.10.6.4 no-access
CPU description table
                                             sc2CPUs 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1 no-access
                                                 sc2cpuUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2cpuNr 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.2 integer read-only
CPU (socket) number (index, 1..n)
                                                 sc2cpuDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.3 displaystring read-only
CPU designation (e.g. CPU-2)
                                                 sc2cpuStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.4 integer read-only
CPU status: unknown(1): CPU status could not be evaluated not-present(2): CPU socket is empty ok(3): CPU is available and working properly disabled(4): CPU was manually disabled in BIOS setup error(5): CPU has encountered errors but is still in use failed(6): CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8): CPU has encountered too many correctable errors within a certain time period and is predicted to fail in near future Enumeration: 'ok': 3, 'prefailure-warning': 8, 'unknown': 1, 'disabled': 4, 'failed': 6, 'not-present': 2, 'error': 5, 'missing-termination': 7.
                                                 sc2cpuModelName 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.5 displaystring read-only
CPU model name (e.g. Pentium Xeon)
                                                 sc2cpuManufacturer 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.6 displaystring read-only
CPU manufacturer name (e.g. Intel)
                                                 sc2cpuStep 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.7 displaystring read-only
CPU step / revision
                                                 sc2cpuCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.8 integer read-only
CPU speed (frequency in MHz, -1 if unknown)
                                                 sc2cpuNumberLogicals 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.9 integer read-only
Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU, -1 if unknown or not available.
                                                 sc2cpuCacheL1Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.10 integer read-only
Size of first level cache (in kBytes, 0 if unknown or not available)
                                                 sc2cpuCacheL2Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.11 integer read-only
Size of second level cache (in kBytes, 0 if unknown or not available)
                                                 sc2cpuCacheL3Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.12 integer read-only
Size of third level cache (in kBytes, 0 if unknown or not available)
                                                 sc2cpuNumberCores 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.13 integer read-only
Number of (physically available) cores within one physical CPU (for multi-core CPUs, platform dependent), 0 if unknown or not available
                                                 sc2cpuFamily 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.14 integer read-only
CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information, type 4).
                                                 sc2cpuEnabledCores 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.15 integer read-only
Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown)
                                                 sc2cpuMultithreadingEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.16 integer read-only
Multithreading of CPU enabled Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3.
                                                 sc2cpuConfigurationStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.17 integer read-only
CPU configuration status: unknown(1): CPU status could not be evaluated normal(2): Regular CPU configuration disabledManually(3): CPU was manually disabled (in BIOS setup) hotSpare(4): CPU is a hot-spare CPU (for future use) mirror(5): CPU is mirrored (for future use) notUsable(7): CPU is currently not usable (due to configuration problems) configurationError(8): CPU misconfiguration Enumeration: 'notUsable': 7, 'disabledManually': 3, 'unknown': 1, 'normal': 2, 'hotSpare': 4, 'configurationError': 8, 'mirror': 5.
                                                 sc2cpuMCDRAMSize 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.18 integer read-only
Size of the onboard MCDRAM (GByte; 0 if no MCDRAM is available)
                                                 sc2cpuMCDRAMSpeed 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.19 integer read-only
Speed of the onboard MCDRAM (MT/s; 0 if no MCDRAM is available)
                                                 sc2cpuMCDRAMMode 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.20 integer read-only
Operation mode of the onboard MCDRAM: undefined(1): Mode is not defined (no MCDRAM available) flat(2): MCDRAM is used as standalone memory exclusively or in addition to external RAM cache(3): MCDRAM is used as a cache for external RAM hybrid(3): Part of MCDRAM is used as a cache, rest as standalone memory (see sc2cpuMCDRAMCacheSize) Enumeration: 'flat': 2, 'cache': 3, 'hybrid': 3, 'undefined': 1.
                                                 sc2cpuMCDRAMCacheSize 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.21 integer read-only
Portion of the onboard MCDRAM used as a cache in hybrid mode (in percent; 0 if no MCDRAM is available or other mode than hybrid)
                                                 sc2cpuMCDRAMMemoryModel 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.22 integer read-only
Memory model of the onboard MCDRAM: undefined(1): Model is not defined (no MCDRAM available) all2all(2): All2All subNumaCluster2(3): Sub NUMA Cluster - 2 subNumaCluster4(4): Sub NUMA Cluster - 4 hemisphere(5): Hemisphere mode quadrant(6): Quadrant mode Enumeration: 'undefined': 1, 'subNumaCluster4': 4, 'subNumaCluster2': 3, 'quadrant': 6, 'hemisphere': 5, 'all2all': 2.
                                         sc2MemoryModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.5 no-access
Main memory module table
                                             sc2MemoryModules 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1 no-access
                                                 sc2memUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2memModuleNr 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.2 integer read-only
Memory module (socket) number (index, 1..n)
                                                 sc2memModuleDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.3 displaystring read-only
Memory module designation (e.g. DIMM-2)
                                                 sc2memModuleStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.4 integer read-only
Memory module status: unknown(1): Module status could not be evaluated not-present(2): Module socket is empty ok(3): Module is available and working properly disabled(4): Module was manually disabled in BIOS setup error(5): Module has encountered errors but is still in use failed(6): Module has failed and was disabled prefailure-predicted(7): Module has encountered too many correctable errors within a certain time period and is predicted to fail in near future hidden(11): Module socket is not available and should be hidden Enumeration: 'ok': 3, 'prefailure-predicted': 7, 'unknown': 1, 'mirror': 9, 'disabled': 4, 'failed': 6, 'not-present': 2, 'error': 5, 'raid': 10, 'hot-spare': 8, 'hidden': 11.
                                                 sc2memModuleBank 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.5 integer read-only
Memory module bank number (-1 if unknown) Due to the fact that modern mainboards do no longer have fixed banks, this value is OBSOLETE!
                                                 sc2memModuleCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.6 integer read-only
Memory module size (capacity in MBytes; -1 if unknown)
                                                 sc2memModuleStartAddress 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.7 integer read-only
Memory module start address (in MBytes; -1 if unknown) Due to the fact that modern mainboards do no longer show start addresses, this value is OBSOLETE!
                                                 sc2memModuleForm 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.8 displaystring read-only
Memory module form (SIMM, DIMM, ...)
                                                 sc2memModuleType 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.9 displaystring read-only
Memory module type (SDRAM, DDRAM, DDR2, DDR3, ...)
                                                 sc2memModuleCorrErrors 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.10 counter read-only
Number of memory module correctable errors (-1 if unknown)
                                                 sc2memModuleUncorrErrors 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.11 counter read-only
Number of memory module uncorrectable errors (-1 if unknown)
                                                 sc2memModuleApproved 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.12 integer read-only
Memory module approved for this machine Enumeration: 'unknown': 1, 'yes': 3, 'no': 2.
                                                 sc2memModuleConfiguration 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.13 integer read-only
Memory module configuration: unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empty disabled(3): Module is disabled (manually through BIOS setup) hotSpare(4): Module is a hot-spare (standby) module, which will be used as a run-time-replacement for failed modules mirror(5): Module is part of a mirror configuration raid(6): Module is part of a RAID configuration notUsable(7): Module is not usable in the actual configuration because of architectural restrictions configurationError(8): Module is not active due to memory misconfiguration This object replaces the previous redundancy status values hot-spare and mirror in sc2memModuleStatus. Enumeration: 'raid': 6, 'notUsable': 7, 'normal': 2, 'unknown': 1, 'hotSpare': 4, 'disabled': 3, 'configurationError': 8, 'mirror': 5.
                                                 sc2memModuleFrequency 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.14 integer read-only
Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings
                                                 sc2memModuleMaxFrequency 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.15 integer read-only
Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data
                                                 sc2memModuleVoltInterface 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.16 displaystring read-only
Memory module interface voltage interface description
                                         sc2cpuMultithreadEnable 1.3.6.1.4.1.231.2.10.2.2.10.6.6 integer read-only
Multithreading of CPU enabled This object is OBSOLETE for future implementations; use object 'sc2cpuMultithreadingEnabled' from 'sc2CPUTable' instead! Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3.
                                         sc2ComponentPowerConsumptionTable 1.3.6.1.4.1.231.2.10.2.2.10.6.7 no-access
Table of component power consumption data
                                             sc2ComponentPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1 no-access
                                                 sc2cpcUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2cpcComponentClass 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.2 integer read-only
Component class enumeration (based on IPMI v1.0 entity ID) Enumeration: 'total-power': 224, 'cooling-device': 29, 'power-supply': 10, 'cooling-unit': 30, 'chassis': 23, 'disk-bay': 26, 'processor-module': 9, 'sub-chassis': 24, 'memory-device': 32, 'system-board': 7, 'gp': 11, 'disk': 4, 'processor': 3, 'memory-unit': 8.
                                                 sc2cpcComponentIndex 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.3 integer read-only
Component index within class (1..n)
                                                 sc2cpcDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.4 displaystring read-only
Component designation
                                                 sc2cpcCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.5 integer read-only
Current component power consumption in Watts
                                         sc2TrustedPlatformModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.8 no-access
Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states)
                                             sc2TrustedPlatformModule 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1 no-access
                                                 sc2tpmUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2tpmHardwareAvailable 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.2 truefalseunknown read-only
TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found)
                                                 sc2tpmBiosEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.3 truefalseunknown read-only
TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value)
                                                 sc2tpmEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.4 truefalseunknown read-only
TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled)
                                                 sc2tpmActivated 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.5 truefalseunknown read-only
TPM is activated (by software; 'unknown' if hardware is not available or disabled)
                                                 sc2tpmOwnership 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.6 truefalseunknown read-only
TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled)
                                         sc2PersistentMemoryModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.9 no-access
Additional information about persistent (non-volatile) memory modules to extend the sc2MemoryModuleTable. This table uses the index numbers of the previous sc2MemoryModuleTable, but only contains rows where a persistent DIMM module is detected.
                                             sc2PersistentMemoryModules 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1 no-access
                                                 sc2nvmemMemoryModeEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.1 truefalseunknown read-only
Volatime memory mode is enabled
                                                 sc2nvmemPersistentModeEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.2 truefalseunknown read-only
Persistent memory mode is enabled
                                                 sc2nvmemPackageSparingCapable 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.3 truefalseunknown read-only
Module is capable of providing spare memory
                                                 sc2nvmemEncryptionEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.4 truefalseunknown read-only
Memory encryption is enabled
                                                 sc2nvmemFirmwareRevision 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.5 displaystring read-only
Firmware revision
                                                 sc2nvmemTotalSize 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.6 integer read-only
Total size of memory module (in GBytes; including reserved spare space)
                                                 sc2nvmemRawCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.7 integer read-only
Maximum capacity that can be allocated for use in any of the supported modes (in GBytes; excluding reserved space)
                                                 sc2nvmemVolatileCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.8 integer read-only
Capacity of volatile memory (in GBytes)
                                                 sc2nvmemPersistentCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.9 integer read-only
Capacity of persistent memory (in GBytes)
                                                 sc2nvmemVolatilePercent 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.10 integer read-only
Capacity of volatile memory (in percent of total size)
                                                 sc2nvmemPersistentPercent 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.11 integer read-only
Capacity of persistent memory (in percent of total size)
                                                 sc2nvmemVolatileStart 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.12 displaystring read-only
Start address of the volatile memory region
                                                 sc2nvmemPersistentStart 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.13 displaystring read-only
Start address of the persistent memory region
                                                 sc2nvmemHealthStatusNonCritical 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.14 truefalseunknown read-only
Non-critical (warning) status
                                                 sc2nvmemHealthStatusCritical 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.15 truefalseunknown read-only
Critical status
                                                 sc2nvmemHealthStatusFatal 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.16 truefalseunknown read-only
Fatal error status (data loss has occurred or is imminent)
                                                 sc2nvmemPowerOnTime 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.17 integer read-only
Lifetime the DIMM has been powered on (in seconds)
                                                 sc2nvmemUpTime 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.18 integer read-only
Current uptime of the DIMM for the current power cycle (in seconds)
                                                 sc2nvmemLiftetimeRemaining 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.19 integer read-only
Remaining predicted lifetime (in seconds; -1 = unknown)
                                                 sc2nvmemAveragePowerBudget 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.20 integer read-only
Average Power Budget in mW
                                                 sc2nvmemPeakPowerBudget 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.21 integer read-only
Peak Power Budget in mW
                                     sc2Recovery 1.3.6.1.4.1.231.2.10.2.2.10.7
                                         sc2MessageLogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.1 no-access
Error and event message handling
                                             sc2MessageLogs 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1 no-access
                                                 sc2msgUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2msgLogEntryNr 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.2 integer read-only
Message log entry number (index, 1..n)
                                                 sc2msgLogEntryData 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.3 octet string read-only
Message log entry data (binary; one message per table entry)
                                         sc2WatchdogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.2 no-access
Watchdogs
                                             sc2Watchdogs 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1 no-access
                                                 sc2wdUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2WatchdogType 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.2 integer read-only
Watchdog type Enumeration: 'management-controller': 6, 'boot': 5, 'hardware': 2, 'bios': 4, 'other': 1, 'remote-management-controller': 7, 'cp': 8, 'software': 3.
                                                 sc2WatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.3 integer read-only
Watchdog status Enumeration: 'disabled': 2, 'unknown': 1, 'enabled': 3, 'not-available': 4.
                                                 sc2WatchdogTime 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.4 integer read-only
Watchdog timeout period in seconds (-1 = unknown)
                                                 sc2WatchdogAction 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.5 integer read-only
Watchdog timeout action; the value unknown(1) can't be written. Not all watchdog type allow setting all of the values (-> BADVALUE). Enumeration: 'reset': 4, 'unknown': 1, 'continue': 2, 'power-cycle': 6, 'nmi': 5.
                                         sc2RecoverySettingTable 1.3.6.1.4.1.231.2.10.2.2.10.7.3 no-access
ASR&R (Automatic server recovery and restart) settings
                                             sc2RecoverySettings 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1 no-access
                                                 sc2asrUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2asrNrRebootRetries 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.2 integer read-only
Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occured. After this number of retries the action defined in 'sc2asrRebootFailAction' will be executed (-1 = unknown, no retries).
                                                 sc2asrDefaultRebootRetries 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.3 integer read-only
Default number of retries for server failure reboot. The above object 'sc2asrNrRebootRetries' will be set to this value after the server is working properly for a certain amount of time.
                                                 sc2asrNextBootSource 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.4 integer read-only
Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI systems, load diagnostic system from alternate IDE disk). remote-disk: boot from remote network disk Enumeration: 'unknown': 1, 'remote-disk': 5, 'reserved': 3, 'operating-system': 2, 'diag-system': 4.
                                                 sc2asrRebootFailAction 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.5 integer read-only
Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero). The value no-diag-system(4) means that a diagnostics system is not available. Enumeration: 'unknown': 1, 'diag-interrupt-assert': 10, 'stop-reboot': 9, 'remote-storage': 8, 'rsb-usb': 7, 'boot-diag-system': 3, 'remote-image-disk': 5, 'no-diag-system': 4, 'switch-off': 2, 'pxe': 6.
                                                 sc2asrRestartDelay 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.6 integer read-only
Delay (in minutes) after that the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero means immediate restart (power-cycle only). Automatic restart may be disabled by setting the 'sc2asrRebootFailAction' to 'switch-off' and the 'sc2asrDefaultRebootRetries' to zero.
                                                 sc2asrPostErrorHalt 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.7 integer read-only
Describes what to do when a POST error has occured (halt on any error, no halt on any error...). Enumeration: 'halt-on-any-error': 2, 'unknown': 1, 'other': 9, 'no-halt-on-any-error': 3.
                                         sc2MessageTextLogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.4 no-access
Error and event message handling, reported as text strings
                                             sc2MessageTextLogs 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1 no-access
                                                 sc2msgTextLogUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2msgTextLogLanguage 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.2 integer read-only
Message log entry language (index, Windows language code) e.g. 1031, 1033 for German, English (default; always available)
                                                 sc2msgTextLogSeqNr 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.3 integer read-only
Message log entry sequence number (index, 1..n)
                                                 sc2msgTextLogTimestamp 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.4 integer read-only
Message log entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
                                                 sc2msgTextLogMessage 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.5 displaystring read-only
Message log entry message string (multi-byte string; multi-language; not every language may be implemented)
                                                 sc2msgTextLogErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.6 integer read-only
Message log entry error code
                                                 sc2msgTextLogSeverity 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.7 integer read-only
Message log entry severity Enumeration: 'major': 3, 'critical': 4, 'informational': 1, 'minor': 2.
                                                 sc2msgTextLogCSSComponent 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.8 truefalse read-only
Component which caused the log message may be replaced by the customer (CSS=Customer Self Service)
                                         sc2MessageLogActionHintTable 1.3.6.1.4.1.231.2.10.2.2.10.7.5 no-access
Action text strings for error and event messages
                                             sc2MessageLogActionHints 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1 no-access
                                                 sc2mlaLanguage 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.1 integer read-only
Action text language (index, Windows language code) e.g. 1031, 1033 for German, English
                                                 sc2mlaErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.2 integer read-only
Action text error code (index)
                                                 sc2mlaType 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.3 integer read-only
Message log entry severity Enumeration: 'resolution': 3, 'cause': 2, 'summary': 1.
                                                 sc2mlaIndex 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.4 integer read-only
Action text entry string index (index, 1..n)
                                                 sc2mlaMessage 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.5 displaystring read-only
Action message string
                                     sc2Status 1.3.6.1.4.1.231.2.10.2.2.10.8
                                         sc2AgentStatus 1.3.6.1.4.1.231.2.10.2.2.10.8.1 compstatus read-only
Overall status of all monitored components in this agent ok(1): all components are working properly; no warnings, no errors warning(2): at least one component reports a warning status or a redundant component reports an error status error(3): at least one non-redundant component reports an error status unknown(5): none of the components has a valid status (e.g. during initialization) notPresent(6): none of the components is present notManageable(7): none of the components is manageable
                                         sc2StatusComponentTable 1.3.6.1.4.1.231.2.10.2.2.10.8.2 no-access
Table with status values of the components in this agent. The table summarizes all instances of one component to one status value.
                                             sc2StatusComponents 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1 no-access
                                                 sc2csUnitId 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2csStatusOverall 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.2 compstatus read-only
Overall status (worst status of all components) in this unit
                                                 sc2csStatusBoot 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.3 compstatus read-only
Boot status (errors from power-on selftest and boot)
                                                 sc2csStatusPowerSupply 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.4 compstatus read-only
Power supply status
                                                 sc2csStatusTemperature 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.5 compstatus read-only
Temperature status
                                                 sc2csStatusFans 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.6 compstatus read-only
Fan status
                                                 sc2csStatusVoltages 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.7 compstatus read-only
Voltage status
                                                 sc2csStatusCpu 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.8 compstatus read-only
CPU status
                                                 sc2csStatusMemoryModule 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.9 compstatus read-only
Memory module status
                                         sc2ComponentStatusSensorTable 1.3.6.1.4.1.231.2.10.2.2.10.8.3 no-access
This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) information.
                                             sc2ComponentStatusSensors 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1 no-access
                                                 sc2cssUnitId 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2cssSensorNumber 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.2 integer read-only
BMC component status sensor number (index, 1..n)
                                                 sc2cssSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.3 displaystring read-only
Component status sensor designation string
                                                 sc2cssSensorDevice 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.4 displaystring read-only
Name of device (entity) the component status sensor belongs to
                                                 sc2cssSensorDeviceInstance 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.5 integer read-only
Instance number of device (entity) the component status sensor belongs to
                                                 sc2cssSensorPhysicalLed 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.6 truefalse read-only
If set, component has a physical status LED showing the sensor status
                                                 sc2cssSensorCssComponent 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.7 truefalse read-only
If set, component may be replaced by the customer (CSS 'custormer-self-service' component)
                                                 sc2cssSensorStatus 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.8 integer read-only
Status returned by the component status sensor Enumeration: 'ok': 2, 'prefailure-warning': 4, 'unknown': 1, 'failure': 5, 'identify': 3, 'not-present': 6.
                                                 sc2cssComponentServicePartId 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.9 displaystring read-only
Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the component's designation string, with blanks substituted by underscores.
                                         sc2cssTableSize 1.3.6.1.4.1.231.2.10.2.2.10.8.4 integer read-only
Number of entries in the component status sensor table
                                     sc2Maintenance 1.3.6.1.4.1.231.2.10.2.2.10.9
                                         sc2MaintenanceObjectTable 1.3.6.1.4.1.231.2.10.2.2.10.9.1 no-access
Table containing some other maintenance objects
                                             sc2MaintenanceObjects 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1 no-access
                                                 sc2mtUnitId 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2ErrorCounterStartTime 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.2 integer read-only
Memory module error counter start time (seconds since 1/1/1970, -1 if unknown). This is the time when the error counters were started or reset last time.
                                                 sc2SendTestTrap 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.3 integer read-write
Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by writing a non-zero value. Reading this object just returns the value 0.
                                                 sc2AddTrapDestination 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.4 ipaddress read-write
Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of this server.
                                         sc2FirmwareVersionTable 1.3.6.1.4.1.231.2.10.2.2.10.9.2 no-access
Controller firmware version table
                                             sc2FirmwareVersions 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1 no-access
                                                 sc2fwUnitId 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                 sc2fwType 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.2 integer read-only
Controller/firmware type Enumeration: 'bios': 1, 'management-controller': 2, 'remote-management-controller': 3.
                                                 sc2fwModelName 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.3 displaystring read-only
Controller/firmware model name (e.g. 'Copernicus'...)
                                                 sc2fwVersion 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.4 displaystring read-only
Controller/firmware version string (e.g. '3.81.02')
                                     sc2Deployment 1.3.6.1.4.1.231.2.10.2.2.10.10
                                           sc2DeployInfoTable 1.3.6.1.4.1.231.2.10.2.2.10.10.1 no-access
Table with data of deployment information. This table is OBSOLETE (no longer used for new implementations)!
                                               sc2DeployInfo 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1 no-access
                                                   sc2dplInfoUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.1 integer read-only
Unit identifier (index, 1..n)
                                                   sc2DeployInfoChassisId 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.2 displaystring read-only
Chassis serial number
                                                   sc2DeployInfoMacAddr1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.3 physaddress read-only
MAC address 1
                                                   sc2DeployInfoMacAddr2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.4 physaddress read-only
MAC address 2
                                                   sc2DeployInfoMacAddr3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.5 physaddress read-only
MAC address 3
                                                   sc2DeployInfoMacAddr4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.6 physaddress read-only
MAC address 4
                                                   sc2DeployInfoIpAddr1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.7 ipaddress read-write
IP address 1
                                                   sc2DeployInfoIpAddr2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.8 ipaddress read-write
IP address 2
                                                   sc2DeployInfoIpAddr3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.9 ipaddress read-write
IP address 3
                                                   sc2DeployInfoIpAddr4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.10 ipaddress read-write
IP address 4
                                                   sc2DeployInfoNetMask1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.11 ipaddress read-write
IP subnet mask 1
                                                   sc2DeployInfoNetMask2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.12 ipaddress read-write
IP subnet mask 2
                                                   sc2DeployInfoNetMask3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.13 ipaddress read-write
IP subnet mask 3
                                                   sc2DeployInfoNetMask4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.14 ipaddress read-write
IP subnet mask 4
                                                   sc2DeployInfoGateway1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.15 ipaddress read-write
IP gateway 1
                                                   sc2DeployInfoGateway2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.16 ipaddress read-write
IP gateway 2
                                                   sc2DeployInfoGateway3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.17 ipaddress read-write
IP gateway 3
                                                   sc2DeployInfoGateway4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.18 ipaddress read-write
IP gateway 4
                                                   sc2DeployInfoHostname 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.19 displaystring read-write
Host name
                                                   sc2DeployInfoMasterImageReference 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.20 displaystring read-write
URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img, *.cfg, *.txt)
                                                   sc2DeployInfoStatusOfBlade 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.21 integer read-write
Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup or boot phase booting(6): ACPI OS currently booting Enumeration: 'standby': 3, 'unknown': 1, 'system-boot-failure': 4, 'power-down': 2, 'booting': 6, 'bios-setup': 5.
                                                   sc2DeployInfoLanStatusOfSlot 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.22 integer read-write
Defines wether the IP-LAN definitions are valid or not. Enumeration: 'true': 3, 'unknown': 1, 'false': 2.
                                                   sc2DeployInfoAutomaticRecovery 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.23 integer read-write
Defines if this server blade should be provided automatic recovery. Enumeration: 'true': 3, 'unknown': 1, 'false': 2.
                                                   sc2DeployInfoStatusOfCloning 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.24 integer read-write
Status of current cloning process. Enumeration: 'unknown': 1, 'cloned': 4, 'cloning': 3, 'not-cloned': 2.
                                                   sc2DeployInfoBootMode 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.25 integer read-write
Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (for OEM systems) pxeLanx(y): boot from PXE LAN interface x (0..3) Enumeration: 'normal': 2, 'unknown': 1, 'pxeLan1': 5, 'pxeLan0': 4, 'pxeLan3': 7, 'pxeLan2': 6, 'pxeBiosSetup': 3.
                                           sc2OemDeployInfoTable 1.3.6.1.4.1.231.2.10.2.2.10.10.2 no-access
Table with data of server OEM information. This table is OBSOLETE (no longer used for new implementations)!
                                               sc2OemDeployInfo 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1 no-access
                                                   sc2odplInfoUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.1 integer read-only
Unit identifier (index, 1..n)
                                                   sc2odplParamId 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.2 integer read-only
OEM parameter ID (index, 1..10)
                                                   sc2OemDeployInfoParamData 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.3 displaystring read-write
OEM parameter data
                                           sc2DeployLanInterfaceTable 1.3.6.1.4.1.231.2.10.2.2.10.10.3 no-access
Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board interfaces are listed; no virtual interfaces.
                                               sc2DeployLanInterfaces 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1 no-access
                                                   sc2dplLanUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.1 integer read-only
Unit identifier (index, 1..n)
                                                   sc2dplLanInterfaceNr 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.2 integer read-only
LAN interface number (index, 1..n)
                                                   sc2dplLanMacAddress 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.3 physaddress read-only
LAN interface hardware (MAC) address
                                     sc2DriverMonitoring 1.3.6.1.4.1.231.2.10.2.2.10.11
                                           sc2DriverMonitorComponentTable 1.3.6.1.4.1.231.2.10.2.2.10.11.1 no-access
Table of components monitored by the driver monitor. Foreign index sc2uUnitId is from sc2UnitTable.
                                               sc2DriverMonitorComponents 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1 no-access
                                                   sc2drvmonCompClass 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.1 integer read-only
Component class (index) Enumeration: 'other': 1, 'storage': 4, 'network': 3, 'software': 2.
                                                   sc2drvmonCompIndex 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.2 integer read-only
Component index (index, 1..n). This is an index over all component classes, but unit specific.
                                                   sc2drvmonCompName 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.3 displaystring read-only
Name or designation of the component
                                                   sc2drvmonCompType 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.4 integer read-only
Component (bus) type Enumeration: 'pci': 2, 'other': 1, 'usb': 3.
                                                   sc2drvmonCompDriverName 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.5 displaystring read-only
Name of the driver that created the event record
                                                   sc2drvmonCompLocationDesignation 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.6 displaystring read-only
Device location designation (if it is an adapter or other hardware component); e.g. 'PCI Slot #2' or 'IOB#1-FUNC#0'
                                                   sc2drvmonCompLocationKey 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.7 displaystring read-only
Device location key, used for identifying the component in other tables (like PCI device table); e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0'
                                                   sc2drvmonCompStatus 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.8 compstatus read-only
Status of the component; caused by specific error events, reset by corresponding 'component OK' events or by manual acknowledge
                                                   sc2drvmonCompErrorAcknowledge 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.9 integer read-write
Acknowledge an error condition (reset error or warning status) of the component by writing a non-zero value (reading this object just returns the value 0)
                                           sc2DriverMonitorMessageTable 1.3.6.1.4.1.231.2.10.2.2.10.11.2 no-access
Table of messages gathered by the driver monitor. The messages are based on the monitored operating system event log and are available in translated languages. Foreign indexes: sc2uUnitId is from sc2UnitTable, sc2msgTextLogLanguage from sc2MessageTextLogTable, sc2drvmonCompClass, sc2drvmonCompType and sc2drvmonCompIndex from sc2DriverMonitorComponentTable. When sc2drvmonCompIndex is 0, the event could not be assigned to any component.
                                               sc2DriverMonitorMessages 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1 no-access
                                                   sc2drvmonMsgSeqNr 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.1 integer read-only
Driver message entry sequence number (index, 1..n)
                                                   sc2drvmonMsgTimestamp 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.2 integer read-only
Driver message entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
                                                   sc2drvmonMsgMessage 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.3 displaystring read-only
Message entry string (multi-language; not every language may be implemented, then English message has to be requested)
                                                   sc2drvmonMsgEventId 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.4 integer read-only
Message entry error code (this code is a driver monitor specific error code)
                                                   sc2drvmonMsgSeverity 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.5 oslogseverity read-only
Message entry severity (may be different from original event log severity)
                                                   sc2drvmonMsgErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.6 integer read-only
Message entry error code (must be used to get summary, causes and resolutions from sc2MessageLogActionHintTable table)
                                                   sc2drvmonOrigLogMessage 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.7 displaystring read-only
Original operating system event log / syslog entry message (only available in the server's original language or in english, depending on the driver that created that entry)
                                                   sc2drvmonOrigLogSource 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.8 displaystring read-only
Original log entry source name
                                                   sc2drvmonOrigLogId 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.9 integer read-only
Original log entry ID number (may not be available for some platforms/controllers, then ID = 0)
                                                   sc2drvmonOrigLogSeverity 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.10 oslogseverity read-only
Original event log entry severity
                                           sc2drvmonTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.11.3 counter read-only
Counter defining the update revision of the driver monitoring tables. This counter is incremented with every change/update of the driver monitoring tables.
                                     sc2Notifications 1.3.6.1.4.1.231.2.10.2.2.10.20
                                           sc2NotificationsTrapInfo 1.3.6.1.4.1.231.2.10.2.2.10.20.1
                                               sc2TrapInfoServerName 1.3.6.1.4.1.231.2.10.2.2.10.20.1.1 displaystring no-access
Name of the server the trap comes from
                                               sc2TrapInfoTime 1.3.6.1.4.1.231.2.10.2.2.10.20.1.2 integer no-access
Time when the trap occured (in seconds since 01/01/1970 00:00h)
                                               sc2TrapInfoCabinetNr 1.3.6.1.4.1.231.2.10.2.2.10.20.1.3 integer no-access
Cabinet number generating the trap
                                               sc2TrapInfoObjectDesignation 1.3.6.1.4.1.231.2.10.2.2.10.20.1.4 displaystring no-access
Designation string for object that generated the trap (fan, temperature sensor...)
                                               sc2TrapInfoString 1.3.6.1.4.1.231.2.10.2.2.10.20.1.5 displaystring no-access
Additional string to be displayed in the trap text
                                               sc2TrapInfoInteger 1.3.6.1.4.1.231.2.10.2.2.10.20.1.6 integer no-access
Additional number to be displayed in the trap text
                                               sc2TrapInfoInteger2 1.3.6.1.4.1.231.2.10.2.2.10.20.1.7 integer no-access
Additional number to be displayed in the trap text
                                             sc2TrapTest 1.3.6.1.4.1.231.2.10.2.2.10.200.2000
Test trap to verify trap connection.
                                             sc2TrapCommunicationFailure 1.3.6.1.4.1.231.2.10.2.2.10.200.2001
The communication with management controller failed!
                                             sc2TrapCommunicationEstablished 1.3.6.1.4.1.231.2.10.2.2.10.200.2002
The communication with the management controller was reestablished
                                             sc2TrapControllerSelftestWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2003
Controller selftest warning.
                                             sc2TrapControllerSelftestError 1.3.6.1.4.1.231.2.10.2.2.10.200.2004
Controller selftest error.
                                             sc2TrapBiosSelftestError 1.3.6.1.4.1.231.2.10.2.2.10.200.2005
A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
                                             sc2TrapSevereSystemError 1.3.6.1.4.1.231.2.10.2.2.10.200.2006
The system was restarted after a severe problem. See server management message log (recovery log) for detailed information.
                                             sc2TrapFanAdded 1.3.6.1.4.1.231.2.10.2.2.10.200.2010
The indicated hot-plug fan or liquid pump was inserted.
                                             sc2TrapFanRemoved 1.3.6.1.4.1.231.2.10.2.2.10.200.2011
The indicated hot-plug fan or liquid pump was removed.
                                             sc2TrapFanOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2012
The indicated fan or liquid pump is working again.
                                             sc2TrapFanCritical 1.3.6.1.4.1.231.2.10.2.2.10.200.2013
The indicated fan or liquid pump became critical
                                             sc2TrapFanFailed 1.3.6.1.4.1.231.2.10.2.2.10.200.2014
The indicated fan or liquid pump failed.
                                             sc2TrapRedundantFanFailed 1.3.6.1.4.1.231.2.10.2.2.10.200.2015
The indicated redundant fan or liquid pump failed
                                             sc2TrapTempOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2020
The temperature of the indicated sensor has decreased to the normal level.
                                             sc2TrapTempWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2021
The temperature of the indicated sensor has reached the warning level.
                                             sc2TrapTempCritical 1.3.6.1.4.1.231.2.10.2.2.10.200.2022
The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
                                             sc2TrapTempSensorOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2023
The indicated broken temperature sensor is OK again.
                                             sc2TrapTempSensorBroken 1.3.6.1.4.1.231.2.10.2.2.10.200.2024
The indicated temperature sensor is broken.
                                             sc2TrapPowerSupplyAdded 1.3.6.1.4.1.231.2.10.2.2.10.200.2030
One hot-replace power supply was added.
                                             sc2TrapPowerSupplyRemoved 1.3.6.1.4.1.231.2.10.2.2.10.200.2031
One hot-replace power supply was removed
                                             sc2TrapPowerSupplyOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2032
Power supply is working again.
                                             sc2TrapPowerSupplyCritical 1.3.6.1.4.1.231.2.10.2.2.10.200.2033
Power supply status has become critical.
                                             sc2TrapPowerSupplyFailed 1.3.6.1.4.1.231.2.10.2.2.10.200.2034
One hot-replace power supply failed.
                                             sc2TrapRedundantPowerSupplyFailed 1.3.6.1.4.1.231.2.10.2.2.10.200.2035
One redundant hot-replace power supply failed
                                             sc2TrapPowerSupplyRedundancyLost 1.3.6.1.4.1.231.2.10.2.2.10.200.2036
Power supply redundancy no longer available.
                                             sc2TrapPowerSupplyCriticalTemperature 1.3.6.1.4.1.231.2.10.2.2.10.200.2037
Critical temperature in power supply.
                                             sc2TrapPowerSupplyFanFailurePrediction 1.3.6.1.4.1.231.2.10.2.2.10.200.2038
Fan failure prediction in power supply.
                                             sc2TrapPowerSupplyFanFailure 1.3.6.1.4.1.231.2.10.2.2.10.200.2039
Fan failure in power supply.
                                             sc2TrapAcFail 1.3.6.1.4.1.231.2.10.2.2.10.200.2040
Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap.
                                             sc2TrapDcFail 1.3.6.1.4.1.231.2.10.2.2.10.200.2041
DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
                                             sc2TrapOnBattery 1.3.6.1.4.1.231.2.10.2.2.10.200.2042
The server is operating on battery power - by UPS or backup battery unit (BBU).
                                             sc2TrapOnMains 1.3.6.1.4.1.231.2.10.2.2.10.200.2043
The mains voltage returned after a power failure.
                                             sc2TrapVoltageOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2050
Power supply voltage is within normal range again.
                                             sc2TrapVoltageTooLow 1.3.6.1.4.1.231.2.10.2.2.10.200.2051
Power supply voltage is too low.
                                             sc2TrapVoltageTooHigh 1.3.6.1.4.1.231.2.10.2.2.10.200.2052
Power supply voltage is too high.
                                             sc2TrapVoltageFailed 1.3.6.1.4.1.231.2.10.2.2.10.200.2053
Power supply voltage is out of range.
                                             sc2TrapBatteryVoltagePrefail 1.3.6.1.4.1.231.2.10.2.2.10.200.2054
Battery is predicted to fail
                                             sc2TrapCorrectableMemErrorAddr 1.3.6.1.4.1.231.2.10.2.2.10.200.2060
A correctable memory error at specified address was detected.
                                             sc2TrapUncorrectableMemErrorAddr 1.3.6.1.4.1.231.2.10.2.2.10.200.2061
An uncorrectable memory error at specified address was detected.
                                             sc2TrapCorrectableMemErrorBank 1.3.6.1.4.1.231.2.10.2.2.10.200.2062
A correctable memory error at specified bank was detected.
                                             sc2TrapUncorrectableMemErrorBank 1.3.6.1.4.1.231.2.10.2.2.10.200.2063
An uncorrectable memory error at specified bank was detected.
                                             sc2TrapCorrectableMemErrorModule 1.3.6.1.4.1.231.2.10.2.2.10.200.2064
A correctable memory error at specified module was detected.
                                             sc2TrapUncorrectableMemErrorModule 1.3.6.1.4.1.231.2.10.2.2.10.200.2065
An uncorrectable memory error at specified module was detected.
                                             sc2TrapCorrectableMemError 1.3.6.1.4.1.231.2.10.2.2.10.200.2066
A correctable memory error at unknown location was detected.
                                             sc2TrapUncorrectableMemError 1.3.6.1.4.1.231.2.10.2.2.10.200.2067
An uncorrectable memory error at unknown location was detected.
                                             sc2TrapMemErrorModulePrefail 1.3.6.1.4.1.231.2.10.2.2.10.200.2068
A memory module is predicted to fail (prefailure).
                                             sc2TrapMemErrorModuleFailing 1.3.6.1.4.1.231.2.10.2.2.10.200.2069
A memory module is failing.
                                             sc2TrapMemErrorModuleReplaced 1.3.6.1.4.1.231.2.10.2.2.10.200.2070
A memory module had failed and was replaced by a hot-spare module.
                                             sc2TrapMemErrorLoggingDisabled 1.3.6.1.4.1.231.2.10.2.2.10.200.2071
Too many correctable memory errors; logging disabled.
                                             sc2TrapMemErrorLoggingEnabled 1.3.6.1.4.1.231.2.10.2.2.10.200.2072
Memory errors logging enabled again.
                                             sc2TrapMemErrorAnyModuleReplaced 1.3.6.1.4.1.231.2.10.2.2.10.200.2073
A memory module had failed and was replaced by a hot-spare module.
                                             sc2TrapMemErrorRedundancyLost 1.3.6.1.4.1.231.2.10.2.2.10.200.2074
A memory error caused loss of memory redundancy
                                             sc2TrapMemNVDIMMLifetime 1.3.6.1.4.1.231.2.10.2.2.10.200.2075
An NVDIMM memory module has reached a certain level of lifetime
                                             sc2TrapCpuSpeedChanged 1.3.6.1.4.1.231.2.10.2.2.10.200.2080
This trap will be sent if the CPU clock frequency was changed because of a temperature problem.
                                             sc2TrapCpuPrefail 1.3.6.1.4.1.231.2.10.2.2.10.200.2081
A CPU is predicted to fail (prefailure).
                                             sc2TrapCpuIerr 1.3.6.1.4.1.231.2.10.2.2.10.200.2082
A CPU internal error (IERR) occurred
                                             sc2TrapCpuDisabled 1.3.6.1.4.1.231.2.10.2.2.10.200.2083
A CPU is disabled by BIOS
                                             sc2TrapCabinetSwitchedOff 1.3.6.1.4.1.231.2.10.2.2.10.200.2090
This trap will be sent when a cabinet is switched off. For obvious reasons it cannot be sent when the main cabinet is switched off.
                                             sc2TrapCabinetSwitchedOn 1.3.6.1.4.1.231.2.10.2.2.10.200.2091
This trap will be sent when a cabinet is switched on.
                                             sc2TrapPowerOffTimeReached 1.3.6.1.4.1.231.2.10.2.2.10.200.2092
This trap is sent when the server is going to be switched off by schedule in some minutes.
                                             sc2TrapServerShutdown 1.3.6.1.4.1.231.2.10.2.2.10.200.2093
This trap will be sent when a server is being shut down.
                                             sc2TrapShutdownCancelled 1.3.6.1.4.1.231.2.10.2.2.10.200.2094
This trap will be sent if a pending server shutdown was cancelled by the user.
                                             sc2TrapBootRetryCountZero 1.3.6.1.4.1.231.2.10.2.2.10.200.2095
This trap will be sent when a boot retry counter gets zero on power up.
                                             sc2TrapServerBoot 1.3.6.1.4.1.231.2.10.2.2.10.200.2096
This trap will be sent when the server was booted
                                             sc2TrapServerStandby 1.3.6.1.4.1.231.2.10.2.2.10.200.2097
This trap will be sent when the server entered standby mode
                                             sc2TrapServerSuspend 1.3.6.1.4.1.231.2.10.2.2.10.200.2098
This trap will be sent when the server entered suspend mode
                                             sc2TrapServerResumed 1.3.6.1.4.1.231.2.10.2.2.10.200.2099
This trap will be sent when the server resumed from standby or suspend mode
                                             sc2TrapMessageLogFull 1.3.6.1.4.1.231.2.10.2.2.10.200.2100
The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types
                                             sc2TrapMessageLogWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2101
The warning threshold for the number of System Event Log entries has been exceeded.
                                             sc2TrapBootMessageLogEntry 1.3.6.1.4.1.231.2.10.2.2.10.200.2102
An error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were running or any error without a specific trap. See server management message log for detailed error description.
                                             sc2TrapIntrusionAssertion 1.3.6.1.4.1.231.2.10.2.2.10.200.2110
The front door or housing was opened
                                             sc2TrapIntrusionDeassertion 1.3.6.1.4.1.231.2.10.2.2.10.200.2111
The front door or housing was closed
                                             sc2TrapIntrusionChanged 1.3.6.1.4.1.231.2.10.2.2.10.200.2112
The front door or housing was opened or closed
                                             sc2TrapPciBusError 1.3.6.1.4.1.231.2.10.2.2.10.200.2113
PCI bus system/parity error
                                             sc2TrapPowerOnTimeReached 1.3.6.1.4.1.231.2.10.2.2.10.200.2114
This trap is sent when the server is going to be switched on by schedule in some minutes. It will be sent by the Remote Management Controller.
                                             sc2TrapCssWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2120
Customer self service component changed to warning status
                                             sc2TrapCssFail 1.3.6.1.4.1.231.2.10.2.2.10.200.2121
Customer self service component changed to fail status
                                             sc2TrapCssWarningServer 1.3.6.1.4.1.231.2.10.2.2.10.200.2122
Customer self service component changed to warning status
                                             sc2TrapCssFailServer 1.3.6.1.4.1.231.2.10.2.2.10.200.2123
Customer self service component changed to fail status
                                             sc2TrapPowerLimitOk 1.3.6.1.4.1.231.2.10.2.2.10.200.2130
Power consumption limit changed to Ok status
                                             sc2TrapPowerLimitWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2131
Power consumption limit changed to warning status
                                             sc2TrapPowerLimitCritical 1.3.6.1.4.1.231.2.10.2.2.10.200.2132
Power consumption limit changed to critical status
                                             sc2TrapPowerLimitDisabled 1.3.6.1.4.1.231.2.10.2.2.10.200.2133
Power consumption limiting disabled
                                             sc2TrapViomInitiateCommunication 1.3.6.1.4.1.231.2.10.2.2.10.200.2140
VIOM communication initiation request - VIOM manager action required. This trap is intended to signal the Virtual IO Manager that the iRMC wants to confirm the usage of the VIOM table. This trap may be repeated several times until the manager responds to the trap.
                                             sc2TrapViomStatusChanged 1.3.6.1.4.1.231.2.10.2.2.10.200.2141
VIOM status has changed - VIOM manager information. If the user or a server management component deactivates VIOM, the iRMC will send a VIOM status trap. This trap will not be sent if VIOM was activated, because no user interface except the Virtual IO Manager shall be capable to enable VIOM.
                                             sc2TrapDrvMonEventMessage 1.3.6.1.4.1.231.2.10.2.2.10.200.2150
Driver Monitoring detected an informational event.
                                             sc2TrapDrvMonEventWarning 1.3.6.1.4.1.231.2.10.2.2.10.200.2151
Driver Monitoring detected a warning event.
                                             sc2TrapDrvMonEventError 1.3.6.1.4.1.231.2.10.2.2.10.200.2152
Driver Monitoring detected an error event.