FDDI-CONCENTRATOR-MIB: View SNMP OID List / Download MIB

VENDOR: FIBRONICS


 Home MIB: FDDI-CONCENTRATOR-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 fibronics 1.3.6.1.4.1.22
       fddiConcentrator 1.3.6.1.4.1.22.70
             concentratorPORT 1.3.6.1.4.1.22.70.1
                 concentratorPORTTable 1.3.6.1.4.1.22.70.1.1 no-access
A list of PORT entries. The number of entries is given by the value of the snmpFddiPORTNumber (see standard fddi.
                     concentratorPORTEntry 1.3.6.1.4.1.22.70.1.1.1 no-access
A PORT entry containing information common to a given PORT.
                         concentratorPORTSMTIndex 1.3.6.1.4.1.22.70.1.1.1.1 integer read-only
The value of the SMT index associated with this PORT.
                         concentratorPORTIndex 1.3.6.1.4.1.22.70.1.1.1.2 integer read-only
A unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of concentratorSMTNonMasterCt { concentratorSMTEntry 6 } and concentratorSMTMasterCt { concentratorSMTEntry 7 } on the given SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
                         concentratorPORTType 1.3.6.1.4.1.22.70.1.1.1.3 integer read-only
This value specifies the type of selected port Enumeration: 'fiber': 2, 'ibm': 5, 'unknown': 1, 'plastic': 6, 'utp': 3, 'stp': 4, 'mono': 8, 'baseT': 7.
                         concentratorPORTStatus 1.3.6.1.4.1.22.70.1.1.1.4 integer read-only
This value specifies the status of the selected port Enumeration: 'failed': 2, 'ok': 1, 'undefind': 3.
             concentratorPROCESSOR 1.3.6.1.4.1.22.70.2
                 concentratorPROCESSORType 1.3.6.1.4.1.22.70.2.1 integer read-only
This value specifies the type of processor Enumeration: 'p386': 6, 'p88': 2, 'p286': 5, 'p86': 3, 'unkown': 1, 'p186': 4, 'p486': 7.
                 concentratorPROCESSORFrequency 1.3.6.1.4.1.22.70.2.2 integer read-only
This value specifies the frequency of the microprocessor (in MHz)
             concentratorMEMORY 1.3.6.1.4.1.22.70.3
                 concentratorSystemMEMORYAvailable 1.3.6.1.4.1.22.70.3.1 integer read-only
This value specifies the amount of memory in kB
                 concentratorSystemMEMORYFree 1.3.6.1.4.1.22.70.3.2 integer read-only
This value specifies the available amount of free memory in kB
                 concentratorBufferMEMORYAvailable 1.3.6.1.4.1.22.70.3.3 integer read-only
This value specifies the amount of memory in kB
                 concentratorMEMORYFlashEPROM 1.3.6.1.4.1.22.70.3.4 integer read-only
This value specifies whether the flash EPROM is present or not Enumeration: 'notpresent': 1, 'present': 2.
             concentratorSERIALPORT 1.3.6.1.4.1.22.70.4
                 concentratorSERIALPORTBaudRate 1.3.6.1.4.1.22.70.4.1 integer read-write
This value specifies the actual baud rate
                 concentratorSERIALPORTParity 1.3.6.1.4.1.22.70.4.2 integer read-only
This value specifies the type of parity Enumeration: 'even': 3, 'none': 1, 'odd': 2.
                 concentratorSERIALPORTStopBits 1.3.6.1.4.1.22.70.4.3 integer read-only
This value specifies the number of stop bits
             concentratorVERSIONS 1.3.6.1.4.1.22.70.5
                 concentratorVERSIONSBoardSerialNumber 1.3.6.1.4.1.22.70.5.1 octet string read-only
This value specifies the serial number of the board
                 concentratorVERSIONSNMP 1.3.6.1.4.1.22.70.5.2 octet string read-only
This value specifies the actual SNMP version
                 concentratorVERSIONBIOS 1.3.6.1.4.1.22.70.5.3 octet string read-only
This value specifies the actual BIOS version
                 concentratorVERSIONSMT 1.3.6.1.4.1.22.70.5.4 octet string read-only
This value specifies the actual SMT version
                 concentratorVERSIONMAC 1.3.6.1.4.1.22.70.5.5 octet string read-only
This value specifies the actual MAC version
                 concentratorVERSIONHRDWR 1.3.6.1.4.1.22.70.5.6 octet string read-only
This value specifies the actual version of the hardware
                 concentratorVERSIONSlotsNumber 1.3.6.1.4.1.22.70.5.7 integer read-only
The number of slots in the concentrator.
                 concentratorVERSIONSlotsTable 1.3.6.1.4.1.22.70.5.8 no-access
A list of slot entries. The number of entries is given by the value of the concentratorVERSIONSlotsNumber.
                     concentratorVERSIONSlotEntry 1.3.6.1.4.1.22.70.5.8.1 no-access
An entry containing information common to a given SLOT number.
                         concentratorVERSIONSlotIndex 1.3.6.1.4.1.22.70.5.8.1.1 integer read-only
The value of the index associated with this particulary slot.
                         concentratorVERSIONSlotSerialNumber 1.3.6.1.4.1.22.70.5.8.1.2 octet string read-only
The serial number of this slot.
                         concentratorVERSIONSlotId 1.3.6.1.4.1.22.70.5.8.1.3 integer read-only
The identification number of this slot.
                         concentratorVERSIONSlotHrdwrStatus 1.3.6.1.4.1.22.70.5.8.1.4 integer read-only
The value specifies the hardware state of the slot.
                         concentratorVERSIONSlotRevision 1.3.6.1.4.1.22.70.5.8.1.5 integer read-only
Revision.
             concentratorPOWER 1.3.6.1.4.1.22.70.6
                 concentratorPOWERFirstSupplyState 1.3.6.1.4.1.22.70.6.1 integer read-only
This value specifies the state of the first power supply Enumeration: 'reserved': 4, 'failure': 2, 'notpresent': 3, 'ok': 1.
                 concentratorPOWERSecondSupplyState 1.3.6.1.4.1.22.70.6.2 integer read-only
This value specifies the state of the second power supply Enumeration: 'reserved': 4, 'failure': 2, 'notpresent': 3, 'ok': 1.
                 concentratorPOWERFirstFANState 1.3.6.1.4.1.22.70.6.3 integer read-only
This value specifies the state of the first fan Enumeration: 'failure': 2, 'ok': 1.
                 concentratorPOWERSecondFANState 1.3.6.1.4.1.22.70.6.4 integer read-only
This value specifies the state of the second power supply Enumeration: 'failure': 2, 'ok': 1.
                 concentratorPOWERTemperature 1.3.6.1.4.1.22.70.6.5 integer read-only
This value specifies the concentrator's temperature (in degrees Celsius)
                 concentratorPOWERBatteryStatus 1.3.6.1.4.1.22.70.6.6 integer read-only
This value specifies the state of the battery Enumeration: 'failure': 2, 'notpresent': 3, 'ok': 1.
             concentratorTRAPS 1.3.6.1.4.1.22.70.7
                 concentratorMgrAddress 1.3.6.1.4.1.22.70.7.1 ipaddress read-write
By means of this variable an SNMP manager can put or remove its own address into or out of the internal array of the manager's addresses to where the agent sends traps.An SNMP manager can set itself by SET SNMP operation with its own IP address. An SNMP manager can remove itself by SET SNMP operation with the 0.0.0.0 IP address. Operation GET or GET-NEXT returns the manager's address if the manager is in the internall array or 0.0.0.0 IP address wheneverthe manager is not in the internal array. Agent returns the following error codes : If a manager tries to set an address IP address different from that of its own address or a manager tries to set 0.0.0.0 IP address when a manager is not present in the internal buffer, the agent returns value BAD VALUE. If a manager tries to set address its own IP address again (when the manager is already in the internal array), the agent returns the value GENERALL ERROR. If this array is already full ,then GENERALL ERROR value is returned.
             concentratorIDENTIFIER 1.3.6.1.4.1.22.70.8
             concentratorTRAFFIC 1.3.6.1.4.1.22.70.9
                 concentratorTRAFFICSMTTransmits 1.3.6.1.4.1.22.70.9.1 counter read-only
This value specifies transmitted SMT frames
                 concentratorTRAFFICSMTReceivs 1.3.6.1.4.1.22.70.9.2 counter read-only
This value specifies the recieved SMT frames
                 concentratorTRAFFICRS232Activity 1.3.6.1.4.1.22.70.9.3 integer read-only
This value specifies whether the RS 232 is currently active Enumeration: 'active': 1, 'nonactive': 2.