FAN-MIB: View SNMP OID List / Download MIB

VENDOR: HEWLETT-PACKARD


 Home MIB: FAN-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hpicfFanMIB 1.3.6.1.4.1.11.2.14.11.5.1.54
The MIB module is for representing switch fan entity.
       hpicfFanScalars 1.3.6.1.4.1.11.2.14.11.5.1.54.1
           hpicfFanUserPrefAirflowDir 1.3.6.1.4.1.11.2.14.11.5.1.54.1.1 integer read-write
The user preferred fan airflow direction. The direction could be powerToPort or portToPower. The actual fan direction has to be changed manually, this will be used to indicate to the user when when the actual fan airflow direction is different from the user preferred airflow direction. Enumeration: 'powerToPort': 2, 'portToPower': 1.
       hpicfEntityFan 1.3.6.1.4.1.11.2.14.11.5.1.54.2
           hpicfFanTable 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1 no-access
This table contains one row for every fan in the switch entity.
               hpicfFanEntry 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1 no-access
Information about fan entity table.
                   hpicfFanIndex 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.1 hpicfdcfanindex no-access
The index that is used to access the switch fan entry table.
                   hpicfFanTray 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.2 integer32 read-only
The tray number in which the fan is docked.
                   hpicfFanType 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.3 hpicfdcfantype read-only
An indication of the vendor-specific fan.
                   hpicfFanState 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4 hpicfdcfanstate read-only
The current state of the fan.
                   hpicfFanRecovering 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.5 integer32 read-only
An indication that the switch fan entity is faulty. Before declaring a fan to be good after a failure is detected, the same good indication must happen five (5) times in a row. A failure indication is always TRUE, while a good indication could be FALSE, hence this parameter is used to count the repeated good indications before declaring the fan to be good
                   hpicfFanNumFailures 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.6 counter32 read-only
The number of times the fan has failed.
                   hpicfFanAirflowDirection 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.7 hpicfdcfanairflowdirection read-only
Indication of the fan air flow direction, either from Power supply towards the port or from the port towards the power supply.
       hpicfFanConformance 1.3.6.1.4.1.11.2.14.11.5.1.54.3
           hpicfFanCompliance 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1
               hpicfDcFanCompliance 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1.1
The compliance statement for entries which implement the FAN MIB.
           hpicfFanGroups 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2
               hpicfFanScalarsGroup 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.1
Basic Scalars required in FAN MIB implementation.
               hpicfFanGroup 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.2
FAN MIB parameters