FAN-MIB: View SNMP OID List / Download MIB
VENDOR: HEWLETT-PACKARD
Home | MIB: FAN-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hpicfFanMIB | 1.3.6.1.4.1.11.2.14.11.5.1.54 |
The MIB module is for representing switch fan entity. |
||
hpicfFanScalars | 1.3.6.1.4.1.11.2.14.11.5.1.54.1 | |||
hpicfFanUserPrefAirflowDir | 1.3.6.1.4.1.11.2.14.11.5.1.54.1.1 | integer | read-write |
The user preferred fan airflow direction. The direction could be powerToPort or portToPower. The actual fan direction has to be changed manually, this will be used to indicate to the user when when the actual fan airflow direction is different from the user preferred airflow direction. Enumeration: 'powerToPort': 2, 'portToPower': 1. |
hpicfEntityFan | 1.3.6.1.4.1.11.2.14.11.5.1.54.2 | |||
hpicfFanTable | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1 | no-access |
This table contains one row for every fan in the switch entity. |
|
1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1 | no-access |
Information about fan entity table. |
||
hpicfFanIndex | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.1 | hpicfdcfanindex | no-access |
The index that is used to access the switch fan entry table. |
hpicfFanTray | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.2 | integer32 | read-only |
The tray number in which the fan is docked. |
hpicfFanType | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.3 | hpicfdcfantype | read-only |
An indication of the vendor-specific fan. |
hpicfFanState | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4 | hpicfdcfanstate | read-only |
The current state of the fan. |
hpicfFanRecovering | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.5 | integer32 | read-only |
An indication that the switch fan entity is faulty. Before declaring a fan to be good after a failure is detected, the same good indication must happen five (5) times in a row. A failure indication is always TRUE, while a good indication could be FALSE, hence this parameter is used to count the repeated good indications before declaring the fan to be good |
hpicfFanNumFailures | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.6 | counter32 | read-only |
The number of times the fan has failed. |
hpicfFanAirflowDirection | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.7 | hpicfdcfanairflowdirection | read-only |
Indication of the fan air flow direction, either from Power supply towards the port or from the port towards the power supply. |
hpicfFanConformance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3 | |||
hpicfFanCompliance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1 | |||
hpicfDcFanCompliance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1.1 |
The compliance statement for entries which implement the FAN MIB. |
||
hpicfFanGroups | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2 | |||
hpicfFanScalarsGroup | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.1 |
Basic Scalars required in FAN MIB implementation. |
||
hpicfFanGroup | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.2 |
FAN MIB parameters |