Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 racktivity 1.3.6.1.4.1.34097
             esRACKTIVITYMIB 1.3.6.1.4.1.34097.9
The MIB module for the Racktivity Devices
                 racktivityNotif 1.3.6.1.4.1.34097.9.0
                     errorValueTooHighRaised 1.3.6.1.4.1.34097.9.0.16
This trap is sent when an element goes above the specified error threshold indicating the maximum value for this element
                     errorValueTooLowRaised 1.3.6.1.4.1.34097.9.0.17
This trap is sent when an element goes below the specified error threshold indicating the minimum value for this element
                     errorRaised 1.3.6.1.4.1.34097.9.0.18
This trap is sent when an element gets into an error state
                     errorValueTooHighCleared 1.3.6.1.4.1.34097.9.0.19
This trap is sent when an element goes below the specified error threshold indicating the maximum value for this element
                     errorValueTooLowCleared 1.3.6.1.4.1.34097.9.0.20
This trap is sent when an element goes above the specified error threshold indicating the minimum value for this element
                     errorCleared 1.3.6.1.4.1.34097.9.0.21
This trap is sent when an element recovers from an error state
                     warningValueTooHighRaised 1.3.6.1.4.1.34097.9.0.48
This trap is sent when an element goes above the specified warning threshold indicating the maximum value for this element
                     warningValueTooLowRaised 1.3.6.1.4.1.34097.9.0.49
This trap is sent when an element goes below the specified warning threshold indicating the minimum value for this element
                     warningRaised 1.3.6.1.4.1.34097.9.0.50
This trap is sent when an element gets into an warning state
                     warningValueTooHighCleared 1.3.6.1.4.1.34097.9.0.51
This trap is sent when an element goes below the specified warning threshold indicating the maximum value for this element
                     warningValueTooLowCleared 1.3.6.1.4.1.34097.9.0.52
This trap is sent when an element goes above the specified warning threshold indicating the minimum value for this element
                     warningCleared 1.3.6.1.4.1.34097.9.0.53
This trap is sent when an element recovers from an warning state
                     warningMicroInterruption 1.3.6.1.4.1.34097.9.0.54
This event is raised when a micro interruption is detected above a threshold time
                     warningPhaseShift 1.3.6.1.4.1.34097.9.0.55
This event is raised when a phase shift is detected above a threshold
                     infoValueTooHighRaised 1.3.6.1.4.1.34097.9.0.80
This trap is sent when an element goes above a specified threshold indicating the maximum value for this element
                     infoValueTooLowRaised 1.3.6.1.4.1.34097.9.0.81
This trap is sent when an element goes below a specified threshold indicating the minimum value for this element
                     infoRaised 1.3.6.1.4.1.34097.9.0.82
This trap is sent when an element gets into a specific state
                     infoValueTooHighCleared 1.3.6.1.4.1.34097.9.0.83
This trap is sent when an element goes below a specified threshold indicating the maximum value for this element
                     infoValueTooLowCleared 1.3.6.1.4.1.34097.9.0.84
This trap is sent when an element goes above a specified threshold indicating the minimum value for this element
                     infoCleared 1.3.6.1.4.1.34097.9.0.85
This trap is sent when an element recovers from a specific state
                     infoPortStateChanged 1.3.6.1.4.1.34097.9.0.96
This trap is sent when a port changes state for any reason
                     infoReset 1.3.6.1.4.1.34097.9.0.97
This trap is sent when a module is reboot
                     infoUpgrade 1.3.6.1.4.1.34097.9.0.98
This trap is sent when upgrade or downgrade of firmware is completed
                     infoPortSchedule 1.3.6.1.4.1.34097.9.0.99
This trap is sent when a port changes state because of a scheduling
                     infoHeartbeat 1.3.6.1.4.1.34097.9.0.100
This trap is sent when a heartbeat has occurred
                 esRacktivityConformance 1.3.6.1.4.1.34097.9.2
                     esRacktivityMIBGroups 1.3.6.1.4.1.34097.9.2.1
                         esRacktivityMIBGroup 1.3.6.1.4.1.34097.9.2.1.1
All accessible objects in a Racktivity device
                         esRacktivityNotificationGroup 1.3.6.1.4.1.34097.9.2.1.2
All notification that can be sent out by a Racktivity device
                     esRacktivityMIBCompliances 1.3.6.1.4.1.34097.9.2.2
                         esRacktivityConpliance 1.3.6.1.4.1.34097.9.2.2.1
The compliance statements for a Racktivity device.
                 esnModule 1.3.6.1.4.1.34097.9.65
                       eESNTable 1.3.6.1.4.1.34097.9.65.1 no-access
Temperature Humidity Presure Airflow Waterleak
                           eESNEntry 1.3.6.1.4.1.34097.9.65.1.1 no-access
Temperature Humidity Presure Airflow Waterleak
                               aGeneralModuleStatus 1.3.6.1.4.1.34097.9.65.1.1.1 unsigned32 read-only
General status of a module.
                               aSpecificModuleStatus 1.3.6.1.4.1.34097.9.65.1.1.2 unsigned32 read-only
Specific status of a module.
                               aCurrentTime 1.3.6.1.4.1.34097.9.65.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               aVoltage 1.3.6.1.4.1.34097.9.65.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               aStatePortCur 1.3.6.1.4.1.34097.9.65.1.1.8 curportstate read-only
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
                               aTemperature 1.3.6.1.4.1.34097.9.65.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               aHumidity 1.3.6.1.4.1.34097.9.65.1.1.12 utenth read-only
Gets the relative humidity. (unit: 0.1RH)
                               aAirflow 1.3.6.1.4.1.34097.9.65.1.1.23 utenth read-only
Gets the current airflow level. (unit: 0.1m/s)
                               aDewPoint 1.3.6.1.4.1.34097.9.65.1.1.25 utenth read-only
Gets the current dewpoint. Taking the current humidity into consideration, condensation will occur if the temperature drops below this level. (unit: 0.1K)
                               aPressure 1.3.6.1.4.1.34097.9.65.1.1.26 utenth read-only
Gets the atmospheric pressure. (unit: 0.1hPa)
                               aAnalogueInput 1.3.6.1.4.1.34097.9.65.1.1.27 unsigned32 read-only
Gets the value of an analog input (voltage). (unit: mV)
                               aWaterleak 1.3.6.1.4.1.34097.9.65.1.1.28 unsigned32 read-only
Gets the current state of the water leak sensor.
                               aMotionDetected 1.3.6.1.4.1.34097.9.65.1.1.29 unsigned32 read-only
Gets or resets whether motion has been detected.
                               aIOPort 1.3.6.1.4.1.34097.9.65.1.1.30 unsigned32 read-only
Gets the state of a digital input.
                               aHighCurrent 1.3.6.1.4.1.34097.9.65.1.1.41 stenth read-only
The current for high values (unit: 0.1A)
                               aHighPower 1.3.6.1.4.1.34097.9.65.1.1.43 shundredth read-only
The power for high values (unit: 0.01kW)
                               aModuleName 1.3.6.1.4.1.34097.9.65.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               aFirmwareVersion 1.3.6.1.4.1.34097.9.65.1.1.10002 version read-only
Gets the version of the module's firmware.
                               aHardwareVersion 1.3.6.1.4.1.34097.9.65.1.1.10003 version read-only
Gets the version of a module's hardware.
                               aFirmwareID 1.3.6.1.4.1.34097.9.65.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               aHardwareID 1.3.6.1.4.1.34097.9.65.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               aDisplayTimeOn 1.3.6.1.4.1.34097.9.65.1.1.10032 unsigned32 read-write
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
                               aMaxVoltageWarning 1.3.6.1.4.1.34097.9.65.1.1.10047 uhundredth read-write
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
                               aMinVoltageWarning 1.3.6.1.4.1.34097.9.65.1.1.10049 uhundredth read-write
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
                               aMinTemperatureWarning 1.3.6.1.4.1.34097.9.65.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               aMaxTemperatureWarning 1.3.6.1.4.1.34097.9.65.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               aMinHumidityWarning 1.3.6.1.4.1.34097.9.65.1.1.10054 utenth read-write
Gets, sets or defaults the minimum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
                               aMaxHumidityWarning 1.3.6.1.4.1.34097.9.65.1.1.10055 utenth read-write
Gets, sets or defaults the maximum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
                               aCurrentWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10078 eventflags read-write
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
                               aPowerWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10080 eventflags read-write
Enables or disables the SNMP trap if the power warning level is exceeded.
                               aVoltageWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10086 eventflags read-write
Enables or disables the SNMP trap if the voltage warning level is exceeded.
                               aTemperatureWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10087 eventflags read-write
Enables or disables the SNMP trap if the temperature warning level is exceeded.
                               aHumidityWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10088 eventflags read-write
Enables or disables the SNMP trap if the humidity warning level is exceeded.
                               aDewPointWarning 1.3.6.1.4.1.34097.9.65.1.1.10092 utenth read-write
Gets, sets or defaults the dewpoint warning level. If the temperature difference between the current temperature and the dewpoint temperature drops below this value, an event is generated. (unit: 0.1K)
                               aDewPointWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10093 eventflags read-write
Enables or disables the SNMP trap if the dewpoint warning level is exceeded.
                               aDewPointViolationEvent 1.3.6.1.4.1.34097.9.65.1.1.10094 eventflags read-write
Enables or disables the SNMP trap if the dewpoint temperature is reached.
                               aPressureWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10095 eventflags read-write
Enables or disables the SNMP trap if the atmospheric pressure warning level is exceeded.
                               aMinPressureWarning 1.3.6.1.4.1.34097.9.65.1.1.10096 utenth read-write
Gets, sets or defaults the minimum atmospheric pressure warning level. (unit: 0.1hPa)
                               aMaxPressureWarning 1.3.6.1.4.1.34097.9.65.1.1.10097 utenth read-write
Gets, sets or defaults the maximum atmospheric pressure warning level. (unit: 0.1hPa)
                               aDisplayBrightness 1.3.6.1.4.1.34097.9.65.1.1.10098 unsigned32 read-write
Gets, sets or defaults the display brightness (if supported).
                               aMotionSensitivity 1.3.6.1.4.1.34097.9.65.1.1.10107 unsigned32 read-write
Gets, sets or defaults the sensitivity of a motion sensor.
                               aExternalSensorLabel 1.3.6.1.4.1.34097.9.65.1.1.10109 displaystring read-write
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
                               aRelayLabel 1.3.6.1.4.1.34097.9.65.1.1.10110 displaystring read-write
Gets, sets or defaults an Energy Sensor relay label.
                               aMinAnalogueInputWarning 1.3.6.1.4.1.34097.9.65.1.1.10111 unsigned32 read-write
Gets, sets or defaults the lower warning level for an analog input. A warning is generated if this level is exceeded. (unit: mV)
                               aMaxAnalogueInputWarning 1.3.6.1.4.1.34097.9.65.1.1.10112 unsigned32 read-write
Gets, sets or defaults the upper warning level for an analog input. A warning is generated if this level is exceeded.
                               aWaterleakWarning 1.3.6.1.4.1.34097.9.65.1.1.10113 unsigned32 read-write
Gets, sets or defaults the water leak detection state (0 = disabled, other values = enabled).
                               aMinAirflowWarning 1.3.6.1.4.1.34097.9.65.1.1.10114 unsigned32 read-write
Gets, sets or defaults the minimum warning level for an airflow sensor. A warning is generated if this level is exceeded.
                               aMaxAirflowWarning 1.3.6.1.4.1.34097.9.65.1.1.10115 unsigned32 read-write
Gets, sets or defaults the maximum warning level for an airflow sensor. A warning is generated if this level is exceeded.
                               aAnalogueInputWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10116 eventflags read-write
Enables or disables the SNMP trap if the analog input warning level is exceeded.
                               aWaterleakWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10117 eventflags read-write
Enables or disables the SNMP trap if a water leak is detected.
                               aAirflowWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10118 eventflags read-write
Enables or disables the SNMP trap if the airflow warning level is exceeded.
                               aRelayAssertActionEvent 1.3.6.1.4.1.34097.9.65.1.1.10119 eventflags read-write
Enables or disables the SNMP trap if an Energy Sensor relay is asserted.
                               aRelayDeassertActionEvent 1.3.6.1.4.1.34097.9.65.1.1.10120 eventflags read-write
Enables or disables the SNMP trap if an Energy Sensor relay is deasserted.
                               aMotionWarning 1.3.6.1.4.1.34097.9.65.1.1.10141 unsigned32 read-write
Gets, sets or defaults the motion warning threshold.
                               aMotionWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10149 eventflags read-write
Enables or disables the SNMP trap if the motion warning threshold is exceeded.
                               aDeviceID 1.3.6.1.4.1.34097.9.65.1.1.10150 displaystring read-only
The ID of the device.
                               aDeviceVersion 1.3.6.1.4.1.34097.9.65.1.1.10151 version read-only
The version of the device.
                               aSysName 1.3.6.1.4.1.34097.9.65.1.1.10152 displaystring read-only
The full name of the device.
                               aMaxHighCurrentWarning 1.3.6.1.4.1.34097.9.65.1.1.10165 stenth read-write
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
                               aMinHighCurrentWarning 1.3.6.1.4.1.34097.9.65.1.1.10176 stenth read-write
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
                               aMinHighPowerWarning 1.3.6.1.4.1.34097.9.65.1.1.10177 shundredth read-write
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
                               aMaxHighPowerWarning 1.3.6.1.4.1.34097.9.65.1.1.10178 shundredth read-write
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
                               aIOPortWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10192 eventflags read-write
Enables or disables the SNMP trap if the IO Port change state.
                               esnIndex 1.3.6.1.4.1.34097.9.65.1.1.65537 integer32 no-access
Index for the selected ESN Module
                               esnModuleIndex 1.3.6.1.4.1.34097.9.65.1.1.65538 integer32 no-access
Selected ESN Module
                 threephasepowerModule 1.3.6.1.4.1.34097.9.66
                       eThreePhasePowerTable 1.3.6.1.4.1.34097.9.66.1 no-access
NO_INFO
                           eThreePhasePowerEntry 1.3.6.1.4.1.34097.9.66.1.1 no-access
NO_INFO
                               threephasepowerIndex 1.3.6.1.4.1.34097.9.66.1.1.65537 integer32 no-access
Index for the selected ThreePhasePower Module
                               threephasepowerModuleIndex 1.3.6.1.4.1.34097.9.66.1.1.65538 integer32 no-access
Selected ThreePhasePower Module
                 displaymoduleModule 1.3.6.1.4.1.34097.9.68
                       eDisplayModuleTable 1.3.6.1.4.1.34097.9.68.1 no-access
NO_INFO
                           eDisplayModuleEntry 1.3.6.1.4.1.34097.9.68.1.1 no-access
NO_INFO
                               dGeneralModuleStatus 1.3.6.1.4.1.34097.9.68.1.1.1 unsigned32 read-only
General status of a module.
                               dSpecificModuleStatus 1.3.6.1.4.1.34097.9.68.1.1.2 unsigned32 read-only
Specific status of a module.
                               dCurrentTime 1.3.6.1.4.1.34097.9.68.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               dTemperature 1.3.6.1.4.1.34097.9.68.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               dTimeOnline 1.3.6.1.4.1.34097.9.68.1.1.24 unsigned32 read-only
Gets the amount of seconds since the last reset. (unit: s)
                               dModuleName 1.3.6.1.4.1.34097.9.68.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               dFirmwareVersion 1.3.6.1.4.1.34097.9.68.1.1.10002 version read-only
Gets the version of the module's firmware.
                               dHardwareVersion 1.3.6.1.4.1.34097.9.68.1.1.10003 version read-only
Gets the version of a module's hardware.
                               dFirmwareID 1.3.6.1.4.1.34097.9.68.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               dHardwareID 1.3.6.1.4.1.34097.9.68.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               dMinTemperatureWarning 1.3.6.1.4.1.34097.9.68.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               dMaxTemperatureWarning 1.3.6.1.4.1.34097.9.68.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               dDisplayAllDevices 1.3.6.1.4.1.34097.9.68.1.1.10237 unsigned32 read-write
If a display need to show all devices or just a small list
                               displaymoduleIndex 1.3.6.1.4.1.34097.9.68.1.1.65537 integer32 no-access
Index for the selected DisplayModule Module
                               displaymoduleModuleIndex 1.3.6.1.4.1.34097.9.68.1.1.65538 integer32 no-access
Selected DisplayModule Module
                 energymonitorModule 1.3.6.1.4.1.34097.9.69
                       eEnergyMonitorTable 1.3.6.1.4.1.34097.9.69.1 no-access
NO_INFO
                           eEnergyMonitorEntry 1.3.6.1.4.1.34097.9.69.1.1 no-access
NO_INFO
                               eGeneralModuleStatus 1.3.6.1.4.1.34097.9.69.1.1.1 unsigned32 read-only
General status of a module.
                               eSpecificModuleStatus 1.3.6.1.4.1.34097.9.69.1.1.2 unsigned32 read-only
Specific status of a module.
                               eCurrentTime 1.3.6.1.4.1.34097.9.69.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               eVoltage 1.3.6.1.4.1.34097.9.69.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               eFrequency 1.3.6.1.4.1.34097.9.69.1.1.5 uthousandth read-only
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
                               eCurrent 1.3.6.1.4.1.34097.9.69.1.1.6 uthousandth read-only
Gets the current of an outlet. (unit: 0.001A)
                               ePower 1.3.6.1.4.1.34097.9.69.1.1.7 unsigned32 read-only
Gets the power of an outlet. (unit: W)
                               eActiveEnergy 1.3.6.1.4.1.34097.9.69.1.1.9 uthousandth read-only
Gets the energy used by an outlet. (unit: 0.001kWh)
                               eApparentEnergy 1.3.6.1.4.1.34097.9.69.1.1.10 uthousandth read-only
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
                               eTemperature 1.3.6.1.4.1.34097.9.69.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               eApparentPower 1.3.6.1.4.1.34097.9.69.1.1.15 unsigned32 read-only
Gets the apparent power of an outlet. (unit: VA)
                               ePowerFactor 1.3.6.1.4.1.34097.9.69.1.1.16 unsigned32 read-only
Gets the power factor of an outlet. (unit: %)
                               eTotalCurrent 1.3.6.1.4.1.34097.9.69.1.1.17 uthousandth read-only
Gets the total current of a power module. (unit: 0.001A)
                               eTotalRealPower 1.3.6.1.4.1.34097.9.69.1.1.18 unsigned32 read-only
Gets the total power level of a power module. (unit: W)
                               eTotalApparentPower 1.3.6.1.4.1.34097.9.69.1.1.19 unsigned32 read-only
Gets the total apparent power of a power module. (unit: VA)
                               eTotalActiveEnergy 1.3.6.1.4.1.34097.9.69.1.1.20 uthousandth read-only
Gets the total energy of a power module. (unit: 0.001kWh)
                               eTotalApparentEnergy 1.3.6.1.4.1.34097.9.69.1.1.21 uthousandth read-only
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
                               eTotalPowerFactor 1.3.6.1.4.1.34097.9.69.1.1.22 unsigned32 read-only
Gets the total power factor of a power module. (unit: %)
                               eTimeOnline 1.3.6.1.4.1.34097.9.69.1.1.24 unsigned32 read-only
Gets the amount of seconds since the last reset. (unit: s)
                               eTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.69.1.1.50 utenth read-only
total harmonic distortion - outlet (unit: 0.1%)
                               eModuleName 1.3.6.1.4.1.34097.9.69.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               eFirmwareVersion 1.3.6.1.4.1.34097.9.69.1.1.10002 version read-only
Gets the version of the module's firmware.
                               eHardwareVersion 1.3.6.1.4.1.34097.9.69.1.1.10003 version read-only
Gets the version of a module's hardware.
                               eFirmwareID 1.3.6.1.4.1.34097.9.69.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               eHardwareID 1.3.6.1.4.1.34097.9.69.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               eMaxCurrentWarning 1.3.6.1.4.1.34097.9.69.1.1.10039 uthousandth read-write
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
                               eMaxPowerWarning 1.3.6.1.4.1.34097.9.69.1.1.10041 unsigned32 read-write
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
                               eMaxTotalCurrentWarning 1.3.6.1.4.1.34097.9.69.1.1.10043 uthousandth read-write
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
                               eMaxTotalPowerWarning 1.3.6.1.4.1.34097.9.69.1.1.10045 unsigned32 read-write
Gets, sets or defaults the maximum total power warning level. (unit: W)
                               eMaxVoltageWarning 1.3.6.1.4.1.34097.9.69.1.1.10047 uhundredth read-write
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
                               eMinVoltageWarning 1.3.6.1.4.1.34097.9.69.1.1.10049 uhundredth read-write
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
                               eMinTemperatureWarning 1.3.6.1.4.1.34097.9.69.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               eMaxTemperatureWarning 1.3.6.1.4.1.34097.9.69.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               eCurrentWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10078 eventflags read-write
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
                               ePowerWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10080 eventflags read-write
Enables or disables the SNMP trap if the power warning level is exceeded.
                               eTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10082 eventflags read-write
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
                               eTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10084 eventflags read-write
Enables or disables the SNMP trap if the total power warning level is exceeded.
                               eVoltageWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10086 eventflags read-write
Enables or disables the SNMP trap if the voltage warning level is exceeded.
                               eTemperatureWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10087 eventflags read-write
Enables or disables the SNMP trap if the temperature warning level is exceeded.
                               eMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.69.1.1.10135 utenth read-write
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
                               eMicroIntEvent 1.3.6.1.4.1.34097.9.69.1.1.10136 eventflags read-write
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
                               energymonitorIndex 1.3.6.1.4.1.34097.9.69.1.1.65537 integer32 no-access
Index for the selected EnergyMonitor Module
                               energymonitorModuleIndex 1.3.6.1.4.1.34097.9.69.1.1.65538 integer32 no-access
Selected EnergyMonitor Module
                 masterModule 1.3.6.1.4.1.34097.9.77
                       eMasterTable 1.3.6.1.4.1.34097.9.77.1 no-access
NO_INFO
                           eMasterEntry 1.3.6.1.4.1.34097.9.77.1.1 no-access
NO_INFO
                               mGeneralModuleStatus 1.3.6.1.4.1.34097.9.77.1.1.1 unsigned32 read-only
General status of a module.
                               mSpecificModuleStatus 1.3.6.1.4.1.34097.9.77.1.1.2 unsigned32 read-only
Specific status of a module.
                               mCurrentTime 1.3.6.1.4.1.34097.9.77.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               mVoltage 1.3.6.1.4.1.34097.9.77.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               mTemperature 1.3.6.1.4.1.34097.9.77.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               mCurrentIP 1.3.6.1.4.1.34097.9.77.1.1.14 ipaddress read-only
Gets the current IP address. To set the IP address, use IPADDR instead.
                               mTotalCurrent 1.3.6.1.4.1.34097.9.77.1.1.17 uthousandth read-only
Gets the total current of a power module. (unit: 0.001A)
                               mTotalRealPower 1.3.6.1.4.1.34097.9.77.1.1.18 unsigned32 read-only
Gets the total power level of a power module. (unit: W)
                               mTotalActiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.20 uthousandth read-only
Gets the total energy of a power module. (unit: 0.001kWh)
                               mLineCurrent 1.3.6.1.4.1.34097.9.77.1.1.32 uthousandth read-only
Gets the current line current. (unit: 0.001A)
                               mFuseCurrent 1.3.6.1.4.1.34097.9.77.1.1.33 uthousandth read-only
Gets the current through a fuse. (unit: 0.001A)
                               mCurrentSubNetMask 1.3.6.1.4.1.34097.9.77.1.1.34 ipaddress read-only
Gets the current subnet mask. To set the subnet mask use SNMSK instead.
                               mCurrentDNSServer 1.3.6.1.4.1.34097.9.77.1.1.35 ipaddress read-only
Gets the current DNS server. To set the DNS server use DNSSRV instead.
                               mCurrentStdGateway 1.3.6.1.4.1.34097.9.77.1.1.36 ipaddress read-only
Gets the current standard gateway. To set the standard gateway use STDGW instead.
                               mUPSPresent 1.3.6.1.4.1.34097.9.77.1.1.37 unsigned32 read-only
Checks if a UPS is present.
                               mUPSStatus 1.3.6.1.4.1.34097.9.77.1.1.38 unsigned32 read-only
Gets the working status of a UPS (if its working on its batteries or not).
                               mUPSEstimatedRunTime 1.3.6.1.4.1.34097.9.77.1.1.39 unsigned32 read-only
Gets the estimated run time of a UPS. (unit: min)
                               mUPSBatteryLevel 1.3.6.1.4.1.34097.9.77.1.1.40 utenth read-only
The current UPS battery level. (unit: 0.1%)
                               mHighCurrent 1.3.6.1.4.1.34097.9.77.1.1.41 stenth read-only
The current for high values (unit: 0.1A)
                               mUpsCommunicationStatus 1.3.6.1.4.1.34097.9.77.1.1.42 unsigned32 read-only
Status information of communication with the UPS
                               mHighPower 1.3.6.1.4.1.34097.9.77.1.1.43 shundredth read-only
The power for high values (unit: 0.01kW)
                               mTotalHighCurrent 1.3.6.1.4.1.34097.9.77.1.1.44 stenth read-only
The current for high values (unit: 0.1A)
                               mTotalHighPower 1.3.6.1.4.1.34097.9.77.1.1.45 shundredth read-only
The power for high values (unit: 0.01kW)
                               mPositiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.46 uthousandth read-only
Gets the positive energy used by an outlet. (unit: 0.001kWh)
                               mNegativeEnergy 1.3.6.1.4.1.34097.9.77.1.1.47 uthousandth read-only
Gets the negative energy used by an outlet. (unit: 0.001kWh)
                               mTotalPositiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.48 uthousandth read-only
Gets the positive energy of the module. (unit: 0.001kWh)
                               mTotalNegativeEnergy 1.3.6.1.4.1.34097.9.77.1.1.49 uthousandth read-only
Gets the negative energy of the module. (unit: 0.001kWh)
                               mCloudStatus 1.3.6.1.4.1.34097.9.77.1.1.56 unsigned32 read-only
Gets the status of the connection with the cloud. 0 = Idle state; 1 = Disabled; 2 = Initialising; 3 = Initialising - No connection; 4 = Initialising - No key; 5 = Connection Ok; 6 = Connection Failed; 7 = Connection Failed - No key.
                               mStatus 1.3.6.1.4.1.34097.9.77.1.1.1000 unsigned32 read-only
status of a module
                               mModuleName 1.3.6.1.4.1.34097.9.77.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               mFirmwareVersion 1.3.6.1.4.1.34097.9.77.1.1.10002 version read-only
Gets the version of the module's firmware.
                               mHardwareVersion 1.3.6.1.4.1.34097.9.77.1.1.10003 version read-only
Gets the version of a module's hardware.
                               mFirmwareID 1.3.6.1.4.1.34097.9.77.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               mHardwareID 1.3.6.1.4.1.34097.9.77.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               mRackName 1.3.6.1.4.1.34097.9.77.1.1.10006 displaystring read-write
Gets, sets or defaults the name of the rack.
                               mRackPosition 1.3.6.1.4.1.34097.9.77.1.1.10007 displaystring read-write
Gets, sets or defaults the position in the rack.
                               mIPAddress 1.3.6.1.4.1.34097.9.77.1.1.10011 ipaddress read-write
Gets, sets or defaults the IP address (when DHCP is disabled).
                               mSubNetMask 1.3.6.1.4.1.34097.9.77.1.1.10012 ipaddress read-write
Gets, sets or defaults the subnet mask (when DHCP is disabled).
                               mStdGateWay 1.3.6.1.4.1.34097.9.77.1.1.10013 ipaddress read-write
Gets, sets or defaults the standard gateway (when DHCP is disabled).
                               mDnsServer 1.3.6.1.4.1.34097.9.77.1.1.10014 ipaddress read-write
Gets, sets or defaults the IP address of the used DNS server (when DHCP is disabled).
                               mMAC 1.3.6.1.4.1.34097.9.77.1.1.10015 macaddress read-only
Gets the MAC address of a master module.
                               mDHCPEnable 1.3.6.1.4.1.34097.9.77.1.1.10016 unsigned32 read-write
Enables, disables or defaults DHCP. Set to 1 to enable DHCP, or 0 to disable DHCP.
                               mNTPServer 1.3.6.1.4.1.34097.9.77.1.1.10017 ipaddress read-write
Gets, sets or defaults the NTP (Network Time Protocol) server IP address.
                               mUseDefaultNTPServer 1.3.6.1.4.1.34097.9.77.1.1.10018 unsigned32 read-write
Enables, disables or defaults the usage of the default NTP (Network Time Protocol) server (pool.ntp.org).
                               mUseNTP 1.3.6.1.4.1.34097.9.77.1.1.10019 unsigned32 read-write
Enables, disables or defaults NTP (Network Time Protocol). Set to 1 to enable NTP, or 0 to disable NTP.
                               mSNMPTrapRecvIP 1.3.6.1.4.1.34097.9.77.1.1.10020 ipaddress read-write
Gets, sets or defaults the SNMP trap receiver IP address.
                               mSNMPTrapRecvPort 1.3.6.1.4.1.34097.9.77.1.1.10021 unsigned32 read-write
Gets, sets or defaults the SNMP tap receiver port.
                               mSNMPControl 1.3.6.1.4.1.34097.9.77.1.1.10024 unsigned32 read-write
Enables, disables or defaults write access over SNMP. Set to 1 to disable write access, or 0 to enable write access.
                               mECSServer 1.3.6.1.4.1.34097.9.77.1.1.10028 ipaddress read-write
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server IP address.
                               mUseECSServer 1.3.6.1.4.1.34097.9.77.1.1.10029 unsigned32 read-write
Enables, disables or defaults the use of an ECS (Energy Cloud Sentinel) server. Set to 1 to enable or 0 to disable.
                               mDisplayLock 1.3.6.1.4.1.34097.9.77.1.1.10031 unsigned32 read-write
Gets, sets or defaults the display lock. If the display is locked, you can still view information on the display, but you are not allowed to change settings through the menu system.
                               mDisplayTimeOn 1.3.6.1.4.1.34097.9.77.1.1.10032 unsigned32 read-write
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
                               mMaxVoltageWarning 1.3.6.1.4.1.34097.9.77.1.1.10047 uhundredth read-write
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
                               mMinVoltageWarning 1.3.6.1.4.1.34097.9.77.1.1.10049 uhundredth read-write
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
                               mMinTemperatureWarning 1.3.6.1.4.1.34097.9.77.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               mMaxTemperatureWarning 1.3.6.1.4.1.34097.9.77.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               mGeneralEventEnable 1.3.6.1.4.1.34097.9.77.1.1.10074 eventflags read-write
Gets, sets or defaults general events. If set to 0, no events will be generated. Set to 1 to generate events on media indicated by the event bitfields.
                               mSNMPSysContact 1.3.6.1.4.1.34097.9.77.1.1.10075 displaystring read-write
Gets, sets or defaults the SNMP contact information.
                               mCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10078 eventflags read-write
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
                               mPowerWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10080 eventflags read-write
Enables or disables the SNMP trap if the power warning level is exceeded.
                               mTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10082 eventflags read-write
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
                               mTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10084 eventflags read-write
Enables or disables the SNMP trap if the total power warning level is exceeded.
                               mVoltageWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10086 eventflags read-write
Enables or disables the SNMP trap if the voltage warning level is exceeded.
                               mTemperatureWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10087 eventflags read-write
Enables or disables the SNMP trap if the temperature warning level is exceeded.
                               mDisplayBrightness 1.3.6.1.4.1.34097.9.77.1.1.10098 unsigned32 read-write
Gets, sets or defaults the display brightness (if supported).
                               mECSServerPort 1.3.6.1.4.1.34097.9.77.1.1.10106 unsigned32 read-write
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server port.
                               mExternalSensorLabel 1.3.6.1.4.1.34097.9.77.1.1.10109 displaystring read-write
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
                               mHttpsOnly 1.3.6.1.4.1.34097.9.77.1.1.10127 unsigned32 read-write
Enables or disables the use of HTTPS (secure HTTP). Set to 1 to enable HTTPS only, or 0 to also enable HTTP.
                               mTelnetSsl 1.3.6.1.4.1.34097.9.77.1.1.10128 unsigned32 read-write
Enables or disables the use of Telnet SSL (secure Telnet). Set to 1 to enable Telnet SSL, or 0 to disable Telnet SSL).
                               mCookieTimeToLive 1.3.6.1.4.1.34097.9.77.1.1.10130 unsigned32 read-write
The TTL (Time To Live) of the website cookie. (unit: min)
                               mLineCurrentWarningThreshold 1.3.6.1.4.1.34097.9.77.1.1.10131 uthousandth read-write
Gets, sets the warning threshold of the linecurrent. (unit: 0.001A)
                               mLineCurrentOffThreshold 1.3.6.1.4.1.34097.9.77.1.1.10132 uthousandth read-write
Gets, sets the off threshold of the linecurrent. (unit: 0.001A)
                               mLineCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10133 eventflags read-write
Enables or disables the SNMP trap if the linecurrent warning level is exceeded.
                               mLineCurrentOffEvent 1.3.6.1.4.1.34097.9.77.1.1.10134 eventflags read-write
Enables or disables the SNMP trap if the linecurrent off level is exceeded.
                               mFuseCurrentWarningThreshold 1.3.6.1.4.1.34097.9.77.1.1.10142 uthousandth read-write
Gets, sets or defaults the maximum current warning threshold per fuse. (unit: 0.001A)
                               mFuseCurrentOffThreshold 1.3.6.1.4.1.34097.9.77.1.1.10143 uthousandth read-write
Gets, sets or defaults the maximum current off threshold per fuse. (unit: 0.001A)
                               mFuseCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10144 eventflags read-write
Enables or disables the SNMP trap if the fusecurrent warning threshold is exceeded.
                               mFuseCurrentOffEvent 1.3.6.1.4.1.34097.9.77.1.1.10145 eventflags read-write
Enables or disables the SNMP trap if the fusecurrent off threshold is exceeded.
                               mDeviceID 1.3.6.1.4.1.34097.9.77.1.1.10150 displaystring read-only
The ID of the device.
                               mDeviceVersion 1.3.6.1.4.1.34097.9.77.1.1.10151 version read-only
The version of the device.
                               mSysName 1.3.6.1.4.1.34097.9.77.1.1.10152 displaystring read-only
The full name of the device.
                               mElectricalTopology 1.3.6.1.4.1.34097.9.77.1.1.10153 unsigned32 read-only
Gets the electrical topology of the unit.
                               mFusePortTopology 1.3.6.1.4.1.34097.9.77.1.1.10154 unsigned32 read-only
Gets the topology between the outlets and fuses.
                               mLineFuseTopology 1.3.6.1.4.1.34097.9.77.1.1.10155 unsigned32 read-only
Gets the topology between the inlet (cable or connection) and the fuses.
                               mSSOIPAddress 1.3.6.1.4.1.34097.9.77.1.1.10156 ipaddress read-write
Gets, sets the IP address of an SSO (Smart Style Office).
                               mSSOLoginCredentials 1.3.6.1.4.1.34097.9.77.1.1.10157 displaystring read-write
Gets, sets the login credentials of an SSO (Smart Style Office).
                               mSSOGracefullShutdown 1.3.6.1.4.1.34097.9.77.1.1.10158 displaystring read-write
Gets, sets the string to send if the UPS' battery level is below the set threshold.
                               mUPSWarningLevel 1.3.6.1.4.1.34097.9.77.1.1.10159 utenth read-write
Gets, sets or defaults the graceful shutdown threshold of a UPS.
                               mUPSOffLevel 1.3.6.1.4.1.34097.9.77.1.1.10160 utenth read-write
Gets, sets or defaults the threshold of a UPS to set outlets off.
                               mMaxHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10165 stenth read-write
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
                               mUpsMonitoringProtocol 1.3.6.1.4.1.34097.9.77.1.1.10167 unsigned32 read-write
Disables/Enables UPS monitoring and selects the protocol used for UPS monitoring. 0 = Disabled; 1 = Use old APC protocol
                               mUpsEmergencyThreshold 1.3.6.1.4.1.34097.9.77.1.1.10168 utenth read-write
When the UPS battery level goes below this threshold a shutdown request will be sent to all agents (unit: 0.1%)
                               mUpsRecoveryThreshold 1.3.6.1.4.1.34097.9.77.1.1.10169 utenth read-write
When the UPS battery level goes above this threshold a outlets will be powered on as configured by the user (unit: 0.1%)
                               mUpsEventFlags 1.3.6.1.4.1.34097.9.77.1.1.10170 eventflags read-write
Event flags for events related to the UPS monitoring
                               mRecoveryPowerThreshold 1.3.6.1.4.1.34097.9.77.1.1.10171 unsigned32 read-write
When the UPS was on battery and it went below UPSEMERGTHRES, the outlets that have a load below the RECOVPOWERTHRES will be power cycled once the UPS is back on mains power and exceeds UPSRECOVTHRES (unit: W)
                               mMinHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10176 stenth read-write
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
                               mMinHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10177 shundredth read-write
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
                               mMaxHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10178 shundredth read-write
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
                               mHeartbeatInterval 1.3.6.1.4.1.34097.9.77.1.1.10179 unsigned32 read-write
Interval (in seconds) between 2 heartbeat SNMP traps, Set to 0 to disable (unit: s)
                               mMinTotalHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10180 stenth read-write
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
                               mMaxTotalHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10181 stenth read-write
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
                               mMinTotalHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10182 shundredth read-write
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
                               mMaxTotalHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10183 shundredth read-write
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
                               mCloudState 1.3.6.1.4.1.34097.9.77.1.1.10208 unsigned32 read-write
Set if the device needs to push info to the init cloud (val=0) or to the normal cloud (val=1)
                               mSensorBias 1.3.6.1.4.1.34097.9.77.1.1.10210 integer32 read-write
get or set the DC sensor bias (unit: mV)
                               mDaisyChainDeviceMode 1.3.6.1.4.1.34097.9.77.1.1.10211 unsigned32 read-write
allowed modes: 0: standalone (master without daisy chain slaves) 1: daisy chain master 2: daisy chain slave 1 3: daisy chain slave 2 4: daisy chain slave 3
                               mSNMPTrapUser 1.3.6.1.4.1.34097.9.77.1.1.10212 unsigned32 read-write
Gets, sets or defaults the SNMP tap user out of the user list.
                               mUSMUser 1.3.6.1.4.1.34097.9.77.1.1.10213 displaystring read-write
Gets, sets or defaults the SNMP USM security user
                               mUSMAuthPassphrase 1.3.6.1.4.1.34097.9.77.1.1.10214 displaystring read-write
Gets, sets or defaults the SNMP USM authentication passphrase (Always MD5)
                               mUSMPrivPassphrase 1.3.6.1.4.1.34097.9.77.1.1.10215 displaystring read-write
Gets, sets or defaults the SNMP USM private passphrase (Always AES)
                               mSNMPV2GetSetEnable 1.3.6.1.4.1.34097.9.77.1.1.10216 unsigned32 read-write
Gets, sets or defaults the SNMP V2 Enable for get ,set or walk but not for traps.
                               mSNMPV3GetSetEnable 1.3.6.1.4.1.34097.9.77.1.1.10217 unsigned32 read-write
Gets, sets or defaults the SNMP V3 Enable for get ,set or walk but not for traps.
                               mUSMAuthPassphraseLength 1.3.6.1.4.1.34097.9.77.1.1.10218 unsigned32 read-write
Gets, sets or defaults the SNMP USM authentication passphrase length
                               mUSMPrivPassphraseLength 1.3.6.1.4.1.34097.9.77.1.1.10219 unsigned32 read-write
Gets, sets or defaults the SNMP USM private passphrase length
                               mSNMPTrapEnable 1.3.6.1.4.1.34097.9.77.1.1.10222 unsigned32 read-write
Gets, sets or defaults the SNMP Trap Enable per trap account
                               mLDAPAttribute 1.3.6.1.4.1.34097.9.77.1.1.10227 displaystring read-write
Attribute linked to the LDAPFilter
                               mLDAPPath 1.3.6.1.4.1.34097.9.77.1.1.10228 displaystring read-write
Relative Path to be used for the LDAPFilter
                               mLDAPAdminGroupName 1.3.6.1.4.1.34097.9.77.1.1.10229 displaystring read-write
GroupName for Admin Credentials in LDAP
                               mLDAPRestrictedGroupName 1.3.6.1.4.1.34097.9.77.1.1.10230 displaystring read-write
GroupName for Restricted Credentials in LDAP
                               mLDAPGuestGroupName 1.3.6.1.4.1.34097.9.77.1.1.10231 displaystring read-write
GroupName for Guest Credentials in LDAP
                               mLDAPEnable 1.3.6.1.4.1.34097.9.77.1.1.10232 unsigned32 read-write
Enable or disable login via LDAP credentials
                               mLDAPLoginWrapper 1.3.6.1.4.1.34097.9.77.1.1.10233 displaystring read-write
Wrapper for login in with LDAP
                               mLDAPServer 1.3.6.1.4.1.34097.9.77.1.1.10235 displaystring read-write
NO_INFO
                               mLocalAuthEnable 1.3.6.1.4.1.34097.9.77.1.1.10236 unsigned32 read-write
Set if local authentication is still possible if LDAP is enabled
                               masterIndex 1.3.6.1.4.1.34097.9.77.1.1.65537 integer32 no-access
Index for the selected Master Module
                               masterModuleIndex 1.3.6.1.4.1.34097.9.77.1.1.65538 integer32 no-access
Selected Master Module
                 powerModule 1.3.6.1.4.1.34097.9.80
                       ePowerTable 1.3.6.1.4.1.34097.9.80.1 no-access
NO_INFO
                           ePowerEntry 1.3.6.1.4.1.34097.9.80.1.1 no-access
NO_INFO
                               pGeneralModuleStatus 1.3.6.1.4.1.34097.9.80.1.1.1 unsigned32 read-only
General status of a module.
                               pSpecificModuleStatus 1.3.6.1.4.1.34097.9.80.1.1.2 unsigned32 read-only
Specific status of a module.
                               pCurrentTime 1.3.6.1.4.1.34097.9.80.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               pVoltage 1.3.6.1.4.1.34097.9.80.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               pFrequency 1.3.6.1.4.1.34097.9.80.1.1.5 uthousandth read-only
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
                               pCurrent 1.3.6.1.4.1.34097.9.80.1.1.6 uthousandth read-only
Gets the current of an outlet. (unit: 0.001A)
                               pPower 1.3.6.1.4.1.34097.9.80.1.1.7 unsigned32 read-only
Gets the power of an outlet. (unit: W)
                               pStatePortCur 1.3.6.1.4.1.34097.9.80.1.1.8 curportstate read-only
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
                               pActiveEnergy 1.3.6.1.4.1.34097.9.80.1.1.9 uthousandth read-only
Gets the energy used by an outlet. (unit: 0.001kWh)
                               pApparentEnergy 1.3.6.1.4.1.34097.9.80.1.1.10 uthousandth read-only
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
                               pTemperature 1.3.6.1.4.1.34097.9.80.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               pApparentPower 1.3.6.1.4.1.34097.9.80.1.1.15 unsigned32 read-only
Gets the apparent power of an outlet. (unit: VA)
                               pPowerFactor 1.3.6.1.4.1.34097.9.80.1.1.16 unsigned32 read-only
Gets the power factor of an outlet. (unit: %)
                               pTotalCurrent 1.3.6.1.4.1.34097.9.80.1.1.17 uthousandth read-only
Gets the total current of a power module. (unit: 0.001A)
                               pTotalRealPower 1.3.6.1.4.1.34097.9.80.1.1.18 unsigned32 read-only
Gets the total power level of a power module. (unit: W)
                               pTotalApparentPower 1.3.6.1.4.1.34097.9.80.1.1.19 unsigned32 read-only
Gets the total apparent power of a power module. (unit: VA)
                               pTotalActiveEnergy 1.3.6.1.4.1.34097.9.80.1.1.20 uthousandth read-only
Gets the total energy of a power module. (unit: 0.001kWh)
                               pTotalApparentEnergy 1.3.6.1.4.1.34097.9.80.1.1.21 uthousandth read-only
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
                               pTotalPowerFactor 1.3.6.1.4.1.34097.9.80.1.1.22 unsigned32 read-only
Gets the total power factor of a power module. (unit: %)
                               pTimeOnline 1.3.6.1.4.1.34097.9.80.1.1.24 unsigned32 read-only
Gets the amount of seconds since the last reset. (unit: s)
                               pTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.80.1.1.50 utenth read-only
total harmonic distortion - outlet (unit: 0.1%)
                               pPhase 1.3.6.1.4.1.34097.9.80.1.1.51 unsigned32 read-only
the phase between 2 waves (unit: degr)
                               pBigCurrent 1.3.6.1.4.1.34097.9.80.1.1.52 unsigned32 read-only
Gets the current of an outlet. (unit: 0.0001A)
                               pBigPower 1.3.6.1.4.1.34097.9.80.1.1.53 uthousandth read-only
Gets the power of an outlet. (unit: 0.001W)
                               pBigApparentPower 1.3.6.1.4.1.34097.9.80.1.1.54 uthousandth read-only
Gets the apparent power of an outlet. (unit: 0.001VA)
                               pDetectedPhase 1.3.6.1.4.1.34097.9.80.1.1.55 unsigned32 read-only
Gives the best matching Phase per currentsensor. Updated every 8s. returnes 255 if no good phaselink is found
                               pModuleName 1.3.6.1.4.1.34097.9.80.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               pFirmwareVersion 1.3.6.1.4.1.34097.9.80.1.1.10002 version read-only
Gets the version of the module's firmware.
                               pHardwareVersion 1.3.6.1.4.1.34097.9.80.1.1.10003 version read-only
Gets the version of a module's hardware.
                               pFirmwareID 1.3.6.1.4.1.34097.9.80.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               pHardwareID 1.3.6.1.4.1.34097.9.80.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               pPortName 1.3.6.1.4.1.34097.9.80.1.1.10034 displaystring read-write
Gets, sets or defaults the name of an outlet.
                               pPortState 1.3.6.1.4.1.34097.9.80.1.1.10035 unsigned32 read-write
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
                               pCurrentPriorOff 1.3.6.1.4.1.34097.9.80.1.1.10036 unsigned32 read-write
Gets, sets or defaults the priority of an outlet. Priority settings are used when 1 or more outlets must be turned off because the total current of a power module was exceeded.
                               pDelayOn 1.3.6.1.4.1.34097.9.80.1.1.10037 unsigned32 read-write
Gets, sets or defaults the outlet turn-on delay. Use this to reduce inrush current when the Energy Switch boots. (unit: s)
                               pMaxCurrentOff 1.3.6.1.4.1.34097.9.80.1.1.10038 uthousandth read-write
Gets, sets or defaults the maximum current off level of an outlet. (unit: 0.001A)
                               pMaxCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10039 uthousandth read-write
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
                               pMaxPowerOff 1.3.6.1.4.1.34097.9.80.1.1.10040 unsigned32 read-write
Gets, sets or defaults the maximum power off level of an outlet. (unit: W)
                               pMaxPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10041 unsigned32 read-write
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
                               pMaxTotalCurrentOff 1.3.6.1.4.1.34097.9.80.1.1.10042 uthousandth read-write
Gets, sets or defaults the total maximum current off level of a power module. (unit: 0.001A)
                               pMaxTotalCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10043 uthousandth read-write
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
                               pMaxTotalPowerOff 1.3.6.1.4.1.34097.9.80.1.1.10044 unsigned32 read-write
Gets, sets or defaults the maximum total power off level. (unit: W)
                               pMaxTotalPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10045 unsigned32 read-write
Gets, sets or defaults the maximum total power warning level. (unit: W)
                               pMaxVoltageWarning 1.3.6.1.4.1.34097.9.80.1.1.10047 uhundredth read-write
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
                               pMinVoltageWarning 1.3.6.1.4.1.34097.9.80.1.1.10049 uhundredth read-write
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
                               pMinTemperatureWarning 1.3.6.1.4.1.34097.9.80.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               pMaxTemperatureWarning 1.3.6.1.4.1.34097.9.80.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               pPortStateEvent 1.3.6.1.4.1.34097.9.80.1.1.10076 eventflags read-write
Enables or disables the SNMP trap if the state of an outlet is changed.
                               pCurrentOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10077 eventflags read-write
Enables or disables the SNMP trap if the outlet current off level is exceeded.
                               pCurrentWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10078 eventflags read-write
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
                               pPowerOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10079 eventflags read-write
Enables or disables the SNMP trap if the power off level is exceeded.
                               pPowerWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10080 eventflags read-write
Enables or disables the SNMP trap if the power warning level is exceeded.
                               pTotalCurrentOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10081 eventflags read-write
Enables or disables the SNMP trap if the total outlet current off level is exceeded.
                               pTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10082 eventflags read-write
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
                               pTotalPowerOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10083 eventflags read-write
Enables or disables the SNMP trap if the total power off level is exceeded.
                               pTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10084 eventflags read-write
Enables or disables the SNMP trap if the total power warning level is exceeded.
                               pVoltageWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10086 eventflags read-write
Enables or disables the SNMP trap if the voltage warning level is exceeded.
                               pTemperatureWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10087 eventflags read-write
Enables or disables the SNMP trap if the temperature warning level is exceeded.
                               pMaxOverheatingOff 1.3.6.1.4.1.34097.9.80.1.1.10090 utenth read-write
Gets, sets or defaults the maximum overheat temperature off level. (unit: 0.1K)
                               pOverheatingOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10091 eventflags read-write
Enables or disables the SNMP trap if the overtemperature off level is exceeded.
                               pPowerCycleTime 1.3.6.1.4.1.34097.9.80.1.1.10099 unsigned32 read-write
Gets, sets or defaults the time interval that is used to do a power cycle of an outlet. (unit: s)
                               pExternalSensorLabel 1.3.6.1.4.1.34097.9.80.1.1.10109 displaystring read-write
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
                               pMaxOverheatingWarning 1.3.6.1.4.1.34097.9.80.1.1.10121 utenth read-write
Gets, sets or defaults the overheating temperature warning level. (unit: 0.1K)
                               pOverheatingWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10122 eventflags read-write
Enables or disables the SNMP trap if the overheat warning level is exceeded.
                               pMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.80.1.1.10135 utenth read-write
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
                               pMicroIntEvent 1.3.6.1.4.1.34097.9.80.1.1.10136 eventflags read-write
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
                               pSoftFuseCurrentThreshold 1.3.6.1.4.1.34097.9.80.1.1.10137 unsigned32 read-write
The threshold of the soft fuse is a factor of the maximum nominal current off (unit: A)
                               pSoftFuseDelay 1.3.6.1.4.1.34097.9.80.1.1.10138 unsigned32 read-write
The minimum time the current of an outlet must be above the soft fuse current threshold to switch it off. (unit: ms)
                               pSoftFuseEvent 1.3.6.1.4.1.34097.9.80.1.1.10139 eventflags read-write
Enables or disables the SNMP trap if a soft fuse is triggered.
                               pPhaseShiftEvent 1.3.6.1.4.1.34097.9.80.1.1.10140 eventflags read-write
Enables or disables the SNMP trap if a phase shift on the voltage is detected.
                               pSchedulePortOnTime 1.3.6.1.4.1.34097.9.80.1.1.10146 unsigned32 read-write
Gets, sets or defaults the time for the scheduler to turn on an outlet. (unit: min)
                               pSchedulePortOffTime 1.3.6.1.4.1.34097.9.80.1.1.10147 unsigned32 read-write
Gets, sets or defaults the time for the scheduler to turn off an outlet. (unit: min)
                               pEnableSchedulePort 1.3.6.1.4.1.34097.9.80.1.1.10148 unsigned32 read-write
Enables or disables the scheduler on an outlet. When enabled the scheduling is repeated daily.
                               pBlockSetPortOff 1.3.6.1.4.1.34097.9.80.1.1.10161 unsigned32 read-write
Prevent outlets to be set off (only delay on and powercycle are still possible).
                               pSchedulePortChangeEvent 1.3.6.1.4.1.34097.9.80.1.1.10166 eventflags read-write
event if a port has changed state because of the scheduler
                               pAgentIP 1.3.6.1.4.1.34097.9.80.1.1.10172 ipaddress read-write
IP address of the agent associated to this outlet
                               pAgentPort 1.3.6.1.4.1.34097.9.80.1.1.10173 unsigned32 read-write
Network port on which the associated agent will listen
                               pAgentCommunicationEventFlags 1.3.6.1.4.1.34097.9.80.1.1.10174 eventflags read-write
Event flags for events related to agent communication
                               pAlwaysOn 1.3.6.1.4.1.34097.9.80.1.1.10175 unsigned32 read-write
Outlets marked as Always On can only be power cycled by the user
                               pGenericTransducerParameters 1.3.6.1.4.1.34097.9.80.1.1.10190 integer32 read-write
sets the slope of the transducer transfer function when the generic transducer type is selected (unit: mA/V)
                               pMaxBigCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10193 unsigned32 read-write
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
                               pMaxBigPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10194 uthousandth read-write
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
                               pGroupNumber 1.3.6.1.4.1.34097.9.80.1.1.10195 unsigned32 read-write
Group number per port to group ports
                               pPhaseLink 1.3.6.1.4.1.34097.9.80.1.1.10196 unsigned32 read-write
Link the current port with a voltage phase
                               pCurrentSensorSelector 1.3.6.1.4.1.34097.9.80.1.1.10197 unsigned32 read-write
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
                               pMinBigCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10209 unsigned32 read-write
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
                               powerIndex 1.3.6.1.4.1.34097.9.80.1.1.65537 integer32 no-access
Index for the selected Power Module
                               powerModuleIndex 1.3.6.1.4.1.34097.9.80.1.1.65538 integer32 no-access
Selected Power Module
                 measuring3phaseModule 1.3.6.1.4.1.34097.9.81
                       eMeasuring3PhaseTable 1.3.6.1.4.1.34097.9.81.1 no-access
NO_INFO
                           eMeasuring3PhaseEntry 1.3.6.1.4.1.34097.9.81.1.1 no-access
NO_INFO
                               qGeneralModuleStatus 1.3.6.1.4.1.34097.9.81.1.1.1 unsigned32 read-only
General status of a module.
                               qSpecificModuleStatus 1.3.6.1.4.1.34097.9.81.1.1.2 unsigned32 read-only
Specific status of a module.
                               qCurrentTime 1.3.6.1.4.1.34097.9.81.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               qVoltage 1.3.6.1.4.1.34097.9.81.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               qFrequency 1.3.6.1.4.1.34097.9.81.1.1.5 uthousandth read-only
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
                               qActiveEnergy 1.3.6.1.4.1.34097.9.81.1.1.9 uthousandth read-only
Gets the energy used by an outlet. (unit: 0.001kWh)
                               qApparentEnergy 1.3.6.1.4.1.34097.9.81.1.1.10 uthousandth read-only
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
                               qTemperature 1.3.6.1.4.1.34097.9.81.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               qPowerFactor 1.3.6.1.4.1.34097.9.81.1.1.16 unsigned32 read-only
Gets the power factor of an outlet. (unit: %)
                               qTimeOnline 1.3.6.1.4.1.34097.9.81.1.1.24 unsigned32 read-only
Gets the amount of seconds since the last reset. (unit: s)
                               qIOPort 1.3.6.1.4.1.34097.9.81.1.1.30 unsigned32 read-only
Gets the state of a digital input.
                               qTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.81.1.1.50 utenth read-only
total harmonic distortion - outlet (unit: 0.1%)
                               qPhase 1.3.6.1.4.1.34097.9.81.1.1.51 unsigned32 read-only
the phase between 2 waves (unit: degr)
                               qBigCurrent 1.3.6.1.4.1.34097.9.81.1.1.52 unsigned32 read-only
Gets the current of an outlet. (unit: 0.0001A)
                               qBigPower 1.3.6.1.4.1.34097.9.81.1.1.53 uthousandth read-only
Gets the power of an outlet. (unit: 0.001W)
                               qBigApparentPower 1.3.6.1.4.1.34097.9.81.1.1.54 uthousandth read-only
Gets the apparent power of an outlet. (unit: 0.001VA)
                               qStatus 1.3.6.1.4.1.34097.9.81.1.1.1000 unsigned32 read-only
status of a module
                               qModuleName 1.3.6.1.4.1.34097.9.81.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               qFirmwareVersion 1.3.6.1.4.1.34097.9.81.1.1.10002 version read-only
Gets the version of the module's firmware.
                               qHardwareVersion 1.3.6.1.4.1.34097.9.81.1.1.10003 version read-only
Gets the version of a module's hardware.
                               qFirmwareID 1.3.6.1.4.1.34097.9.81.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               qHardwareID 1.3.6.1.4.1.34097.9.81.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               qPortState 1.3.6.1.4.1.34097.9.81.1.1.10035 unsigned32 read-write
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
                               qMaxVoltageWarning 1.3.6.1.4.1.34097.9.81.1.1.10047 uhundredth read-write
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
                               qMinVoltageWarning 1.3.6.1.4.1.34097.9.81.1.1.10049 uhundredth read-write
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
                               qMinTemperatureWarning 1.3.6.1.4.1.34097.9.81.1.1.10052 utenth read-write
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               qMaxTemperatureWarning 1.3.6.1.4.1.34097.9.81.1.1.10053 utenth read-write
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
                               qPortStateEvent 1.3.6.1.4.1.34097.9.81.1.1.10076 eventflags read-write
Enables or disables the SNMP trap if the state of an outlet is changed.
                               qCurrentWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10078 eventflags read-write
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
                               qPowerWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10080 eventflags read-write
Enables or disables the SNMP trap if the power warning level is exceeded.
                               qVoltageWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10086 eventflags read-write
Enables or disables the SNMP trap if the voltage warning level is exceeded.
                               qTemperatureWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10087 eventflags read-write
Enables or disables the SNMP trap if the temperature warning level is exceeded.
                               qMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.81.1.1.10135 utenth read-write
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
                               qMicroIntEvent 1.3.6.1.4.1.34097.9.81.1.1.10136 eventflags read-write
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
                               qDeviceID 1.3.6.1.4.1.34097.9.81.1.1.10150 displaystring read-only
The ID of the device.
                               qDeviceVersion 1.3.6.1.4.1.34097.9.81.1.1.10151 version read-only
The version of the device.
                               qMaxBigCurrentWarning 1.3.6.1.4.1.34097.9.81.1.1.10193 unsigned32 read-write
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
                               qMaxBigPowerWarning 1.3.6.1.4.1.34097.9.81.1.1.10194 uthousandth read-write
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
                               qCurrentSensorSelector 1.3.6.1.4.1.34097.9.81.1.1.10197 unsigned32 read-write
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
                               qMinBigCurrentWarning 1.3.6.1.4.1.34097.9.81.1.1.10209 unsigned32 read-write
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
                               qkWhMode 1.3.6.1.4.1.34097.9.81.1.1.10234 unsigned32 read-write
Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative
                               measuring3phaseIndex 1.3.6.1.4.1.34097.9.81.1.1.65537 integer32 no-access
Index for the selected Measuring3Phase Module
                               measuring3phaseModuleIndex 1.3.6.1.4.1.34097.9.81.1.1.65538 integer32 no-access
Selected Measuring3Phase Module
                 pcModule 1.3.6.1.4.1.34097.9.85
                       ePCTable 1.3.6.1.4.1.34097.9.85.1 no-access
NO_INFO
                           ePCEntry 1.3.6.1.4.1.34097.9.85.1.1 no-access
NO_INFO
                               uGeneralModuleStatus 1.3.6.1.4.1.34097.9.85.1.1.1 unsigned32 read-only
General status of a module.
                               uSpecificModuleStatus 1.3.6.1.4.1.34097.9.85.1.1.2 unsigned32 read-only
Specific status of a module.
                               uCurrentTime 1.3.6.1.4.1.34097.9.85.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               uVoltage 1.3.6.1.4.1.34097.9.85.1.1.4 uhundredth read-only
Gets the voltage of a power module. (unit: 0.01V)
                               uCurrent 1.3.6.1.4.1.34097.9.85.1.1.6 uthousandth read-only
Gets the current of an outlet. (unit: 0.001A)
                               uStatePortCur 1.3.6.1.4.1.34097.9.85.1.1.8 curportstate read-only
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
                               uTemperature 1.3.6.1.4.1.34097.9.85.1.1.11 utenth read-only
Gets the current temperature of a temperature sensor. (unit: 0.1K)
                               uHumidity 1.3.6.1.4.1.34097.9.85.1.1.12 utenth read-only
Gets the relative humidity. (unit: 0.1RH)
                               uModuleName 1.3.6.1.4.1.34097.9.85.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               uFirmwareVersion 1.3.6.1.4.1.34097.9.85.1.1.10002 version read-only
Gets the version of the module's firmware.
                               uHardwareVersion 1.3.6.1.4.1.34097.9.85.1.1.10003 version read-only
Gets the version of a module's hardware.
                               uFirmwareID 1.3.6.1.4.1.34097.9.85.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               uHardwareID 1.3.6.1.4.1.34097.9.85.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               uPortState 1.3.6.1.4.1.34097.9.85.1.1.10035 unsigned32 read-write
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
                               pcIndex 1.3.6.1.4.1.34097.9.85.1.1.65537 integer32 no-access
Index for the selected PC Module
                               pcModuleIndex 1.3.6.1.4.1.34097.9.85.1.1.65538 integer32 no-access
Selected PC Module
                 testmoduleModule 1.3.6.1.4.1.34097.9.89
                       eTestModuleTable 1.3.6.1.4.1.34097.9.89.1 no-access
Module to test the R-bus
                           eTestModuleEntry 1.3.6.1.4.1.34097.9.89.1.1 no-access
Module to test the R-bus
                               yGeneralModuleStatus 1.3.6.1.4.1.34097.9.89.1.1.1 unsigned32 read-only
General status of a module.
                               ySpecificModuleStatus 1.3.6.1.4.1.34097.9.89.1.1.2 unsigned32 read-only
Specific status of a module.
                               yCurrentTime 1.3.6.1.4.1.34097.9.89.1.1.3 timeticks read-write
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
                               yCurrent 1.3.6.1.4.1.34097.9.89.1.1.6 uthousandth read-only
Gets the current of an outlet. (unit: 0.001A)
                               yStatePortCur 1.3.6.1.4.1.34097.9.89.1.1.8 curportstate read-only
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
                               yAnalogueInput 1.3.6.1.4.1.34097.9.89.1.1.27 unsigned32 read-only
Gets the value of an analog input (voltage). (unit: mV)
                               yModuleName 1.3.6.1.4.1.34097.9.89.1.1.10001 displaystring read-write
Gets, sets or defaults the module name.
                               yFirmwareVersion 1.3.6.1.4.1.34097.9.89.1.1.10002 version read-only
Gets the version of the module's firmware.
                               yHardwareVersion 1.3.6.1.4.1.34097.9.89.1.1.10003 version read-only
Gets the version of a module's hardware.
                               yFirmwareID 1.3.6.1.4.1.34097.9.89.1.1.10004 displaystring read-only
Gets the ID of the module's firmware.
                               yHardwareID 1.3.6.1.4.1.34097.9.89.1.1.10005 displaystring read-only
Gets the ID of a module's hardware.
                               testmoduleIndex 1.3.6.1.4.1.34097.9.89.1.1.65537 integer32 no-access
Index for the selected TestModule Module
                               testmoduleModuleIndex 1.3.6.1.4.1.34097.9.89.1.1.65538 integer32 no-access
Selected TestModule Module