Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
eriRouterPvcMib | 1.3.6.1.4.1.193.218.2.7 |
Defines the objects necessary to support the management of ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits (PVC). |
||
eriRouterPvcMIBObjects | 1.3.6.1.4.1.193.218.2.7.1 | |||
eriRouterAtmPvcConfigTable | 1.3.6.1.4.1.193.218.2.7.1.1 | no-access |
This table contains the objects which identify and configure ATM PVCs. |
|
1.3.6.1.4.1.193.218.2.7.1.1.1 | no-access |
A conceptual row in the eriRouterAtmPvcConfigTable. |
||
eriRouterAtmPvcSlot | 1.3.6.1.4.1.193.218.2.7.1.1.1.1 | erirouterslot | no-access |
The chassis slot number |
eriRouterAtmPvcPort | 1.3.6.1.4.1.193.218.2.7.1.1.1.2 | erirouterport | no-access |
The port number |
eriRouterAtmPvcVpi | 1.3.6.1.4.1.193.218.2.7.1.1.1.3 | unsigned32 | no-access |
The Virtual Path Identifier for the PVC. |
eriRouterAtmPvcVci | 1.3.6.1.4.1.193.218.2.7.1.1.1.4 | unsigned32 | no-access |
The Virtual Channel Identifier for the PVC. |
eriRouterAtmPvcProfileName | 1.3.6.1.4.1.193.218.2.7.1.1.1.5 | snmpadminstring | read-only |
The profile name to use with the PVC. |
eriRouterAtmPvcEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.1.1.6 | erirouteratmencapsulation | read-only |
The encapsulation to use with the PVC. |
eriRouterAtmPvcRowStatus | 1.3.6.1.4.1.193.218.2.7.1.1.1.8 | rowstatus | read-only |
The row status for creating, modifying, or deleting an entry in the table. |
eriRouterAtmPvcCircuitType | 1.3.6.1.4.1.193.218.2.7.1.1.1.9 | erirouterpvccircuittype | read-only |
The PVC circuit type. With respect to this mib object, only those entries whose eriRouterAtmPvcCircuitType has a value 'explicit' may be removed by setting eriRouterAtmPvcRowStatus equal to 'destroy'. A set operation with eriRouterAtmPvcRowStatus equal to 'destroy' on any row with eriRouterAtmPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
eriRouterAtmPvcCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.1.1.10 | eriroutercircuithandle | read-only |
This object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB. |
eriRouterAtmPvcClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.1.1.11 | truthvalue | read-only |
When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1483(2) or route1483(4), subscribers will re-authenticate after being cleared. |
eriRouterFrameRelayPvcConfigTable | 1.3.6.1.4.1.193.218.2.7.1.2 | no-access |
This table contains the objects which identify and configure Frame Relay PVCs. |
|
1.3.6.1.4.1.193.218.2.7.1.2.1 | no-access |
A conceptual row in the eriRouterFrameRelayPvcConfigTable. |
||
eriRouterFrameRelayPvcSlot | 1.3.6.1.4.1.193.218.2.7.1.2.1.1 | erirouterslot | no-access |
The chassis slot number |
eriRouterFrameRelayPvcPort | 1.3.6.1.4.1.193.218.2.7.1.2.1.2 | erirouterport | no-access |
The port number |
eriRouterFrameRelayPvcChannel | 1.3.6.1.4.1.193.218.2.7.1.2.1.3 | unsigned32 | no-access |
The channel number |
eriRouterFrameRelayPvcDLCI | 1.3.6.1.4.1.193.218.2.7.1.2.1.4 | unsigned32 | no-access |
The Data Link Connection Identifier |
eriRouterFrameRelayPvcProfileName | 1.3.6.1.4.1.193.218.2.7.1.2.1.5 | snmpadminstring | read-only |
The profile name to use with the PVC. |
eriRouterFrameRelayPvcEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.2.1.6 | erirouterframerelayencapsulation | read-only |
The encapsulation to use with the PVC. |
eriRouterFrameRelayPvcRowStatus | 1.3.6.1.4.1.193.218.2.7.1.2.1.8 | rowstatus | read-only |
The row status for creating, modifying, or deleting an entry in the table. |
eriRouterFrameRelayPvcCircuitType | 1.3.6.1.4.1.193.218.2.7.1.2.1.9 | erirouterpvccircuittype | read-only |
The PVC circuit type. With respect to this mib object, only those entries whose eriRouterFrameRelayPvcCircuitType has a value 'explicit' may be removed by setting eriRouterFrameRelayPvcRowStatus equal to 'destroy'. A set operation with eriRouterFrameRelayPvcRowStatus equal to 'destroy' on any row with eriRouterFrameRelayPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
eriRouterFrameRelayPvcCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.2.1.10 | eriroutercircuithandle | read-only |
This object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB. |
eriRouterFrameRelayPvcClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.2.1.11 | truthvalue | read-only |
When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1490(2) or route1490(4), subscribers will re-authenticate after being cleared. |
eriRouterDot1qPvcOnEthConfigTable | 1.3.6.1.4.1.193.218.2.7.1.3 | no-access |
This table contains the objects which identify and configure IEEE 802.1Q PVCs on Ethernet ports. |
|
1.3.6.1.4.1.193.218.2.7.1.3.1 | no-access |
A conceptual row in the eriRouterDot1qPvcOnEthConfigTable. |
||
eriRouterDot1qPvcOnEthSlot | 1.3.6.1.4.1.193.218.2.7.1.3.1.1 | erirouterslot | no-access |
The chassis slot number. |
eriRouterDot1qPvcOnEthPort | 1.3.6.1.4.1.193.218.2.7.1.3.1.2 | erirouterport | no-access |
The port number. |
eriRouterDot1qPvcOnEthVlanId | 1.3.6.1.4.1.193.218.2.7.1.3.1.3 | eriroutervidoruntagged | no-access |
IEEE 802.1Q Virtual LAN (VLAN) tag value. |
eriRouterDot1qPvcOnEthRowStatus | 1.3.6.1.4.1.193.218.2.7.1.3.1.4 | rowstatus | read-only |
The row status for creating, modifying, or deleting an entry in the table. |
eriRouterDot1qPvcOnEthProfileName | 1.3.6.1.4.1.193.218.2.7.1.3.1.5 | snmpadminstring | read-only |
The profile name to use with the PVC. |
eriRouterDot1qPvcOnEthEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.3.1.6 | erirouterdot1qencapsulation | read-only |
The encapsulation to use with the PVC. |
eriRouterDot1qPvcOnEthCircuitType | 1.3.6.1.4.1.193.218.2.7.1.3.1.7 | erirouterpvccircuittype | read-only |
The PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnEthCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnEthRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnEthRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnEthCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
eriRouterDot1qPvcOnEthCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.3.1.8 | eriroutercircuithandle | read-only |
This object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB. |
eriRouterDot1qPvcOnEthClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.3.1.9 | truthvalue | read-only |
When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. |
eriRouterDot1qPvcOnAtmConfigTable | 1.3.6.1.4.1.193.218.2.7.1.4 | no-access |
This table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits. |
|
1.3.6.1.4.1.193.218.2.7.1.4.1 | no-access |
A conceptual row in the eriRouterDot1qPvcOnAtmConfigTable. |
||
eriRouterDot1qPvcOnAtmSlot | 1.3.6.1.4.1.193.218.2.7.1.4.1.1 | erirouterslot | no-access |
The chassis slot number. |
eriRouterDot1qPvcOnAtmPort | 1.3.6.1.4.1.193.218.2.7.1.4.1.2 | erirouterport | no-access |
The port number. |
eriRouterDot1qPvcOnAtmVpi | 1.3.6.1.4.1.193.218.2.7.1.4.1.3 | unsigned32 | no-access |
The Virtual Path Identifier for the PVC. |
eriRouterDot1qPvcOnAtmVci | 1.3.6.1.4.1.193.218.2.7.1.4.1.4 | unsigned32 | no-access |
The Virtual Channel Identifier for the PVC. |
eriRouterDot1qPvcOnAtmVlanId | 1.3.6.1.4.1.193.218.2.7.1.4.1.5 | eriroutervidoruntagged | no-access |
IEEE 802.1Q Virtual LAN (VLAN) tag value. |
eriRouterDot1qPvcOnAtmRowStatus | 1.3.6.1.4.1.193.218.2.7.1.4.1.6 | rowstatus | read-only |
The row status for creating, modifying, or deleting an entry in the table. |
eriRouterDot1qPvcOnAtmProfileName | 1.3.6.1.4.1.193.218.2.7.1.4.1.7 | snmpadminstring | read-only |
The profile name to use with the PVC. |
eriRouterDot1qPvcOnAtmEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.4.1.8 | erirouterdot1qencapsulation | read-only |
The encapsulation to use with the PVC. |
eriRouterDot1qPvcOnAtmCircuitType | 1.3.6.1.4.1.193.218.2.7.1.4.1.9 | erirouterpvccircuittype | read-only |
The PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnAtmCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnAtmCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
eriRouterDot1qPvcOnAtmCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.4.1.10 | eriroutercircuithandle | read-only |
This object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB. |
eriRouterDot1qPvcOnAtmClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.4.1.11 | truthvalue | read-only |
When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. |
eriRouterDot1qPvcOnFrConfigTable | 1.3.6.1.4.1.193.218.2.7.1.5 | no-access |
This table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits. |
|
1.3.6.1.4.1.193.218.2.7.1.5.1 | no-access |
A conceptual row in the eriRouterDot1qPvcOnFrConfigTable. |
||
eriRouterDot1qPvcOnFrSlot | 1.3.6.1.4.1.193.218.2.7.1.5.1.1 | erirouterslot | no-access |
The chassis slot number. |
eriRouterDot1qPvcOnFrPort | 1.3.6.1.4.1.193.218.2.7.1.5.1.2 | erirouterport | no-access |
The port number. |
eriRouterDot1qPvcOnFrChannel | 1.3.6.1.4.1.193.218.2.7.1.5.1.3 | unsigned32 | no-access |
The channel number. |
eriRouterDot1qPvcOnFrDLCI | 1.3.6.1.4.1.193.218.2.7.1.5.1.4 | unsigned32 | no-access |
The Data Link Connection Identifier. |
eriRouterDot1qPvcOnFrVlanId | 1.3.6.1.4.1.193.218.2.7.1.5.1.5 | eriroutervidoruntagged | no-access |
IEEE 802.1Q Virtual LAN (VLAN) tag value. |
eriRouterDot1qPvcOnFrRowStatus | 1.3.6.1.4.1.193.218.2.7.1.5.1.6 | rowstatus | read-only |
The row status for creating, modifying, or deleting an entry in the table. |
eriRouterDot1qPvcOnFrProfileName | 1.3.6.1.4.1.193.218.2.7.1.5.1.7 | snmpadminstring | read-only |
The profile name to use with the PVC. |
eriRouterDot1qPvcOnFrEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.5.1.8 | erirouterdot1qencapsulation | read-only |
The encapsulation to use with the PVC. |
eriRouterDot1qPvcOnFrCircuitType | 1.3.6.1.4.1.193.218.2.7.1.5.1.9 | erirouterpvccircuittype | read-only |
The PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnFrCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnFrRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnFrRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnFrCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
eriRouterDot1qPvcOnFrCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.5.1.10 | eriroutercircuithandle | read-only |
This object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB. |
eriRouterDot1qPvcOnFrClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.5.1.11 | truthvalue | read-only |
When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. |
eriRouterPvcMIBConformance | 1.3.6.1.4.1.193.218.2.7.2 | |||
eriRouterPvcCompliances | 1.3.6.1.4.1.193.218.2.7.2.1 | |||
eriRouterPvcCompliance | 1.3.6.1.4.1.193.218.2.7.2.1.1 |
The compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB. |
||
eriRouterPvcCompliance2 | 1.3.6.1.4.1.193.218.2.7.2.1.2 |
The compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB. |
||
eriRouterPvcCompliance3 | 1.3.6.1.4.1.193.218.2.7.2.1.3 |
The compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB. |
||
eriRouterPvcGroups | 1.3.6.1.4.1.193.218.2.7.2.2 | |||
eriRouterAtmPvcGroup | 1.3.6.1.4.1.193.218.2.7.2.2.1 |
the collection of objects which represent the ATM PVC. |
||
eriRouterFrameRelayPvcGroup | 1.3.6.1.4.1.193.218.2.7.2.2.2 |
the collection of objects which represent the FrameRelay PVC. |
||
eriRouterAtmPvcGroup2 | 1.3.6.1.4.1.193.218.2.7.2.2.3 |
The collection of objects which represent the ATM PVC. |
||
eriRouterFrameRelayPvcGroup2 | 1.3.6.1.4.1.193.218.2.7.2.2.4 |
The collection of objects which represent the FrameRelay PVC. |
||
eriRouterDot1qPvcOnEthGroup | 1.3.6.1.4.1.193.218.2.7.2.2.5 |
A collection of objects providing information specific to IEEE 802.1Q PVCs on Ethernet ports. |
||
eriRouterDot1qPvcOnAtmGroup | 1.3.6.1.4.1.193.218.2.7.2.2.6 |
A collection of objects providing information specific to IEEE 802.1Q PVCs on ATM circuits. |
||
eriRouterDot1qPvcOnFrGroup | 1.3.6.1.4.1.193.218.2.7.2.2.7 |
A collection of objects providing information specific to IEEE 802.1Q PVCs on Frame Relay circuits. |
||
eriRouterPvcMIBNotifications | 1.3.6.1.4.1.193.218.2.7.3 |