ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB: View SNMP OID List / Download MIB
VENDOR: ERICSSON AB
Home | MIB: ERICSSON-ROUTER-OPTICAL-TRANSCEIVER-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
eriRouterOpticalTransceiverAlarm | 1.3.6.1.4.1.193.218.2.49.0.2 |
An eriRouterOpticalTransceiverAlarm notification signifies that an alarm has been raised or cleared on a Optical Transceiver |
||
eriRouterOpticalTransceiverLaneAlarm | 1.3.6.1.4.1.193.218.2.49.0.3 |
An eriRouterOpticalTransceiverLaneAlarm notification signifies that an alarm has been raised or cleared in a lane on a Optical Transceiver |
||
eriRouterOpticalTransceiverMonMIBGroups | 1.3.6.1.4.1.193.218.2.49.2.3 | |||
eriRouterOpticalTransceiverMonMIBNotificationGroup | 1.3.6.1.4.1.193.218.2.49.2.3.2 |
A collection of notifications providing Optical Transceiver fault condition |
||
eriRouterOpticalTransceiverMonMIBCompliances | 1.3.6.1.4.1.193.218.2.49.2.4 | |||
eriRouterOpticalTransceiverMonMIBCompliance | 1.3.6.1.4.1.193.218.2.49.2.4.1 |
The compliance statement for the OpticalTransceiver MIB |
||
eriRouterOpticalTransceiver | 1.3.6.1.4.1.193.218.2.50 |
The MIB used to manage the Optical Transceivers in Line Card ports in SSR |
||
eriRouterOpticalTransceiverDetails | 1.3.6.1.4.1.193.218.2.50.1 | |||
eriRouterOpticalTransceiverPortTable | 1.3.6.1.4.1.193.218.2.50.1.1 | no-access |
This table contains the ports with optical transceivers and corresponding parameters |
|
1.3.6.1.4.1.193.218.2.50.1.1.1 | no-access |
Line Card port optical transceiver parameter description. |
||
eriRouterOpticalTransceiverCardSlot | 1.3.6.1.4.1.193.218.2.50.1.1.1.1 | erirouterslot | read-only |
The chassis slot number in which the card is present where the Optical Transceiver plugged in. |
eriRouterOpticalTransceiverPort | 1.3.6.1.4.1.193.218.2.50.1.1.1.2 | erirouterport | read-only |
The port number where the Optical Transceiver plugged in. |
eriRouterOpticalTransceiverType | 1.3.6.1.4.1.193.218.2.50.1.1.1.3 | octet string | read-only |
Type and category of Optical Transceiver |
eriRouterOpticalTransceiverMediaType | 1.3.6.1.4.1.193.218.2.50.1.1.1.4 | octet string | read-only |
Optical Transceiver Media Type |
eriRouterOpticalTransceiverEriRouterEricssonApproved | 1.3.6.1.4.1.193.218.2.50.1.1.1.5 | truthvalue | read-only |
Is the Optical Transceiver n this port approved by Ericsson, Yes/No? |
eriRouterOpticalTransceiverDiagMonitoring | 1.3.6.1.4.1.193.218.2.50.1.1.1.6 | truthvalue | read-only |
Is Optical Transceiver Diag Monitoring On or Off? |
eriRouterOpticalTransceiverCLEIcode | 1.3.6.1.4.1.193.218.2.50.1.1.1.7 | octet string | read-only |
Optical Transceiver Common Language Equipment Identifier (CLEI) code. |
eriRouterOpticalTransceiverSerialNo | 1.3.6.1.4.1.193.218.2.50.1.1.1.8 | octet string | read-only |
Optical Transceiver serial number |
eriRouterOpticalTransceiverFrequency | 1.3.6.1.4.1.193.218.2.50.1.1.1.9 | octet string | read-only |
Optical Transceiver Frequency |
eriRouterOpticalTransceiverWaveLength | 1.3.6.1.4.1.193.218.2.50.1.1.1.10 | erirouteropticaltransceiverparamwavelength | read-only |
Optical Transceiver Wave Length |
eriRouterOpticalTransceiverAdditionalFeatures | 1.3.6.1.4.1.193.218.2.50.1.1.1.11 | octet string | read-only |
Optical Transceiver Additional Features such as, Is Optical Transceiver OTN capable? and/or Is Optical Transceiver Tunable? |
eriRouterOpticalTransceiverFrequencyStart | 1.3.6.1.4.1.193.218.2.50.1.1.1.12 | octet string | read-only |
Frequency Start for tunable optical transceiver. Not applicable if optical transceiver is not tunable |
eriRouterOpticalTransceiverFrequencyEnd | 1.3.6.1.4.1.193.218.2.50.1.1.1.13 | octet string | read-only |
Frequency End for tunable optical transceiver. Not applicable if optical transceiver is not tunable |
eriRouterOpticalTransceiverFrequencySpacing | 1.3.6.1.4.1.193.218.2.50.1.1.1.14 | octet string | read-only |
Frequency Spacing for tunable optical transceiver. Not applicable if optical transceiver is not tunable |
eriRouterOpticalTransceiverOTNFramer | 1.3.6.1.4.1.193.218.2.50.1.1.1.15 | octet string | read-only |
Framer of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable |
eriRouterOpticalTransceiverOTNFEC | 1.3.6.1.4.1.193.218.2.50.1.1.1.16 | octet string | read-only |
FEC of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable |
eriRouterOpticalTransceiverPowerLevel | 1.3.6.1.4.1.193.218.2.50.1.1.1.17 | octet string | read-only |
Optical Transceiver Power Level |
eriRouterOpticalTransceiverActiveAlarmCount | 1.3.6.1.4.1.193.218.2.50.1.1.1.18 | integer | read-only |
Number of alarms active on the Optical Transceiver |
eriRouterOpticalTransceiverParamBitMask | 1.3.6.1.4.1.193.218.2.50.1.1.1.19 | integer32 | read-only |
This Bit Mask indicates which values are valid for EriRouterOpticalTransceiverParamType in eriRouterOpticalTransceiverParamTable: 0x0001 optical transceiver txpower valid 0x0002 optical transceiver rxpower valid 0x0004 optical transceiver temperature valid 0x0008 optical transceiver laserBiasCurrent valid 0x0010 optical transceiver soaBiasCurrent valid 0x0020 optical transceiver Vcc valid 0x0040 optical transceiver aux1 valid 0x0080 optical transceiver aux2 valid 0x0100 optical transceiver lane txpower valid 0x0200 optical transceiver lane rxpower valid 0x0400 optical transceiver lane temperature valid 0x0800 optical transceiver lane laserBiasCurrent valid |
eriRouterOpticalTransceiverLaneCount | 1.3.6.1.4.1.193.218.2.50.1.1.1.20 | integer | read-only |
Number of Lanes in optical transceiver |
eriRouterOpticalTransceiverParamTable | 1.3.6.1.4.1.193.218.2.50.1.2 | no-access |
This table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters. |
|
1.3.6.1.4.1.193.218.2.50.1.2.1 | no-access |
OpticalTransceiver Parameter Entries in Table |
||
eriRouterOpticalTransceiverParamType | 1.3.6.1.4.1.193.218.2.50.1.2.1.1 | erirouteropticaltransceiverparamtype | read-only |
This object specifies the optical parameter type that is being monitored in this entry. |
eriRouterOpticalTransceiverParamDescription | 1.3.6.1.4.1.193.218.2.50.1.2.1.2 | octet string | read-only |
This object specifies the optical parameter description including units that is being monitored in this entry. |
eriRouterOpticalTransceiverCurrentValue | 1.3.6.1.4.1.193.218.2.50.1.2.1.3 | erirouteropticaltransceiverparametervalue | read-only |
The current value of tx power, rx power, temperature, bias current and Vcc |
eriRouterOpticalTransceiverMaxAlarmValue | 1.3.6.1.4.1.193.218.2.50.1.2.1.4 | erirouteropticaltransceiverparametervalue | read-only |
The alarm high threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterOpticalTransceiverMaxWarningValue | 1.3.6.1.4.1.193.218.2.50.1.2.1.5 | erirouteropticaltransceiverparametervalue | read-only |
The warning high threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterOpticalTransceiverMinAlarmValue | 1.3.6.1.4.1.193.218.2.50.1.2.1.6 | erirouteropticaltransceiverparametervalue | read-only |
The alarm low threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterOpticalTransceiverMinWarningValue | 1.3.6.1.4.1.193.218.2.50.1.2.1.7 | erirouteropticaltransceiverparametervalue | read-only |
The warning low threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterLaneInOpticalTransceiverParamTable | 1.3.6.1.4.1.193.218.2.50.1.3 | no-access |
This table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters. |
|
1.3.6.1.4.1.193.218.2.50.1.3.1 | no-access |
LaneInOpticalTransceiver Parameter Entries in Table |
||
eriRouterLaneInOpticalTransceiver | 1.3.6.1.4.1.193.218.2.50.1.3.1.1 | integer32 | read-only |
This object specifies the optical tranceiver lane that is being monitored in this entry. |
eriRouterLaneInOpticalTransceiverParamType | 1.3.6.1.4.1.193.218.2.50.1.3.1.2 | erirouterlaneinopticaltransceiverparamtype | read-only |
This object specifies the optical parameter type that is being monitored in this entry. |
eriRouterLaneInOpticalTransceiverCurrentValue | 1.3.6.1.4.1.193.218.2.50.1.3.1.3 | erirouterlaneinopticaltransceiverparametervalue | read-only |
The current value of tx power, rx power, temperature, bias current and Vcc |
eriRouterLaneInOpticalTransceiverMaxAlarmValue | 1.3.6.1.4.1.193.218.2.50.1.3.1.4 | erirouterlaneinopticaltransceiverparametervalue | read-only |
The alarm high threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterLaneInOpticalTransceiverMaxWarningValue | 1.3.6.1.4.1.193.218.2.50.1.3.1.5 | erirouterlaneinopticaltransceiverparametervalue | read-only |
The warning high threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterLaneInOpticalTransceiverMinAlarmValue | 1.3.6.1.4.1.193.218.2.50.1.3.1.6 | erirouterlaneinopticaltransceiverparametervalue | read-only |
The alarm low threshold value of tx power, rx power, temperature, bias current and Vcc |
eriRouterLaneInOpticalTransceiverMinWarningValue | 1.3.6.1.4.1.193.218.2.50.1.3.1.7 | erirouterlaneinopticaltransceiverparametervalue | read-only |
The warning low threshold value of tx power, rx power, temperature, bias current and Vcc |