Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
         dnxStm1Oc3 1.3.6.1.4.1.644.2.4.2.7
             dnxStm1Oc3Enterprise 1.3.6.1.4.1.644.2.4.2.7.0
ERI DNX Stm1Oc3 Device Enterprise for Alarms/Events
                 optDevConfigTrap 1.3.6.1.4.1.644.2.4.2.7.0.1
This trap is used to notify a NMS that a user has updated the configuration for a given Stm1Oc3 Device entry.
                 optT1E1ConfigTrap 1.3.6.1.4.1.644.2.4.2.7.0.2
This trap is used to notify a NMS that a user has updated the configuration for a given Stm1Oc3 T1/E1 Link entry.
             opticalConfig 1.3.6.1.4.1.644.2.4.2.7.1
                 opticalDevConfigTable 1.3.6.1.4.1.644.2.4.2.7.1.1 no-access
This is the STM1/OC3 Device Configuration table which consists of an entry for each of the STM1/OC3 cards. The total number of entries depends on the number of STM1/OC3 cards in the Node.
                     opticalDevConfigEntry 1.3.6.1.4.1.644.2.4.2.7.1.1.1 no-access
The conceptual row of the STM1/OC3 Device Configuration table. A row in this table cannot be added or deleted, only modified.
                         optDevCfgAddr 1.3.6.1.4.1.644.2.4.2.7.1.1.1.1 nestslotaddress read-only
This number uniquely identifies a STM1/OC3 Device resource. This number will be used throughout the system to identify a unique resource.
                         optDevCfgResource 1.3.6.1.4.1.644.2.4.2.7.1.1.1.2 integer32 read-only
Uniquely identifies an STM1/OC3 Device in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
                         optDevType 1.3.6.1.4.1.644.2.4.2.7.1.1.1.3 integer read-only
Identifies the Device as an STM1, OC3, STM1X, or OC3X module. Enumeration: 'stm1X': 2, 'oc3': 1, 'stm1': 0, 'oc3X': 3.
                         optDevMultiplexMode 1.3.6.1.4.1.644.2.4.2.7.1.1.1.4 integer read-write
Determines the Stm1Oc3 Multiplexing Map Structure to be used: For STM1 SDH Device choose au3, au4, or au4-g707: ------------------------------------------------- (0) au3 - Maps the AUG (Administrative Unit Group) to an AU-3: C-12<-->VC-12<-->TU-12<-->TUG-2<-->VC-3<-->AU-3<-->AUG<-->STM-1 (1) au4 - Maps the AUG (Administrative Unit Group) to an AU-4: C-12<-->VC-12<-->TU-12<-->TUG-2<-->TUG-3<-->VC-4<-->AU-4<-->AUG<-->STM-1 (4) au4-vc3-Seq - Same format as AU-4 but uses sequential link numbering scheme For OC3 SONET Device sts-3 or sts-3c: ------------------------------------- (2) sts-3 - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE: VT-1.5<-->VT-G<-->SPE<-->STS-3<-->OC-3 (3) sts-3c - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE 3c: SPE3c<-->STS-3<-->OC-3 Enumeration: 'sts-3c': 3, 'au3': 0, 'au4-vc3-Seq': 4, 'au4': 1, 'sts-3': 2.
                         optLineTiming 1.3.6.1.4.1.644.2.4.2.7.1.1.1.5 integer read-write
Identifies the type of Clock Transmit Timing to use for the STM-1 or OC-3 module. Enumeration: 'local': 0, 'loop': 1.
                         optDevPayload1 1.3.6.1.4.1.644.2.4.2.7.1.1.1.6 payloadgrouptype read-write
Indicates the group framing type to be used for links 1 through 28. Using E1, links 22 through 28 are not used.
                         optDevPayload2 1.3.6.1.4.1.644.2.4.2.7.1.1.1.7 payloadgrouptype read-write
Indicates the tgroup framing type to be used for links 29 through 56. Using E1, links 50 through 56 are not used.
                         optDevPayload3 1.3.6.1.4.1.644.2.4.2.7.1.1.1.8 payloadgrouptype read-write
Indicates the group framing type to be used for links 57 through 84. Using E1, links 78 through 84 are not used.
                         optDevCmdStatus 1.3.6.1.4.1.644.2.4.2.7.1.1.1.9 integer read-write
The command status for this link configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Stm1Oc3 Device Cfg Commands used in SET Command (1..99) update-config(1), Change existing Stm1Oc3 Device Configuration Response States used in GET RESPONSE Command (100..199) update-successful (101) Device data has been successfully changed Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799) err-general-opt-config-error (400) Unknown Device configuration error occurred err-au4Seq-cannot-be-mixed-framing (402) Au4 sequential mode supports only all-E1 or all-T1 Payloads err-invalid-opt-dev-command (403) Unrecognized device command-action err-device-is-protection-module (414) Can't configure Device designated as Protection (odd # slot) err-invalid-multiplex-map (415) Configured multiplexing structure not valid for device type err-invalid-payload-framing (416) Unrecognized payload group type err-invalid-xlink-nest-num (419) X-Link cannot be assigned to selected Nest err-invalid-line-timing (421) Unrecognized clock setting err-ts-alloc-not-applicable (424) Timeslot Alloc can only be configured for STM1 or OC3 cards in Standalone DNX systems err-xlink-pair-not-applicable (427) X-Link assignement can only be changed for STM1X or OC3X cards in DNX88 systems. err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name. err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big Enumeration: 'err-invalid-snmp-type': 501, 'err-invalid-xlink-nest-num': 419, 'err-invalid-line-timing': 421, 'err-device-is-protection-module': 414, 'err-general-opt-config-error': 400, 'err-invalid-opt-dev-command': 403, 'err-invalid-payload-framing': 416, 'err-data-locked-by-another-user': 450, 'err-invalid-snmp-var-size': 502, 'err-snmp-parse-failed': 500, 'err-ts-alloc-not-applicable': 424, 'update-successful': 101, 'err-invalid-multiplex-map': 415, 'err-xlink-pair-not-applicable': 427, 'ready-for-command': 0, 'update-config': 1, 'err-au4Seq-cannot-be-mixed-framing': 402.
                         optDevTsAlloc 1.3.6.1.4.1.644.2.4.2.7.1.1.1.10 integer read-write
Identifies the Timeslot allocation method to use for the STM-1 or OC-3 module. Only applies for stand-alone DNX-11 or DNX-4 systems. DNX-88 systems always use NORMAL. Enumeration: 'alternate': 1, 'normal': 0.
                         optDevAssignedToNest 1.3.6.1.4.1.644.2.4.2.7.1.1.1.11 integer32 read-write
Identifies the virtual Nest to use for the STM1-X or OC3-X modules. Only applicable in DNX-88 systems and can only be SET for cards configured in even numbered DNX slots.
                 optT1E1LinkConfigTable 1.3.6.1.4.1.644.2.4.2.7.1.2 no-access
This is the Stm1Oc3 T1/E1 Link Configuration table which consists of an entry for each of the card's 84 links. The total number of entries depends on the number of STM1 and/or OC3 cards in the Node.
                     optT1E1LinkConfigEntry 1.3.6.1.4.1.644.2.4.2.7.1.2.1 no-access
The conceptual row of the Stm1Oc3 T1/E1 Link Configuration table. A row in this table cannot be added or deleted, only modified.
                         optT1E1CfgLinkAddr 1.3.6.1.4.1.644.2.4.2.7.1.2.1.1 linkportaddress read-only
This number uniquely identifies a Stm1Oc3 T1/E1 Link resource. This number will be used throughout the system to identify a unique resource.
                         optT1E1CfgResource 1.3.6.1.4.1.644.2.4.2.7.1.2.1.2 integer32 read-only
Uniquely identifies an Stm1Oc3 T1/E1 Link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
                         optT1E1CfgLinkName 1.3.6.1.4.1.644.2.4.2.7.1.2.1.3 displaystring read-write
This is the user friendly text name to identify the link.
                         optT1E1Status 1.3.6.1.4.1.644.2.4.2.7.1.2.1.4 portstatus read-write
Dictates the current status of the link, in-service or out-of-service.
                         optT1E1Clear 1.3.6.1.4.1.644.2.4.2.7.1.2.1.5 integer read-write
Determines if the port supports T1 or E1 unframed clear mode or framed clear mode. Enumeration: 'disabled': 0, 'unframed': 2, 'framed': 1.
                         optT1E1Framing 1.3.6.1.4.1.644.2.4.2.7.1.2.1.6 integer read-write
Determines the type of framing used on the line. Choose between T1 SuperFrame 'D4', Extended SuperFrame (ESF), or T1 Unframed. When value of optT1E1Clear is set to unframed (2), the only valid framing options are: e1Unframed(4) or t1Unframed(7). Enumeration: 'e1Unframed': 4, 'e1Cas': 2, 't1Esf': 5, 'e1Crc': 1, 'e1CasCrc': 3, 't1D4': 6, 't1Unframed': 7, 'e1': 0.
                         optT1E1RecoverTime 1.3.6.1.4.1.644.2.4.2.7.1.2.1.7 integer read-write
This is the red alarm timeout value. Determines the amount of seconds the port will wait to stop sending the yellow alarm when coming out of a red alarm condition. Enumeration: 'timeout-15-secs': 15, 'timeout-3-secs': 3, 'timeout-10-secs': 10.
                         optT1E1EsfFormat 1.3.6.1.4.1.644.2.4.2.7.1.2.1.8 integer read-write
Determines the type of ESF network commands the T-1 link will respond to. It has no meaning for D4 or E1 networks. With ESF networks, this information must be obtained from the network supplier. Enumeration: 'ansi-t1-403': 1, 'att-54016': 0.
                         optT1E1UnusedTSs 1.3.6.1.4.1.644.2.4.2.7.1.2.1.9 integer read-write
Determines the whether the code that will be transmitted over the unused timeslots will be 'idle' or 'busy' (all 1's). Enumeration: 'idle': 1, 'busy': 0.
                         optT1E1CfgCmdStatus 1.3.6.1.4.1.644.2.4.2.7.1.2.1.10 linkcmdstatus read-write
The command status for this link configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row optical T1E1 Link Commands used in SET Command (1..199) update(1) Change existing Link Configuration inServiceAll (7) Change Link Status to in-service for all links within the same payload. copyToAll (9) Copy T1/E1 Link configuration to all other links within the same payload outOfServiceAll (12) Change Link Status to out-of-service for all links within the same payload. Response States used in GET RESPONSE Command (100..199) update-successful (101) Link data has been successfully changed insvc-successful (107) All Payload Links have been successfully placed In Service copy-successful (109) Link data has been successfully copied to other links oos-successful (112) All Payload Links have been successfully placed Out of Service optical T1E1 Link Config Error Codes used in GET RESPONSE Command (400..699) err-general-link-config-error (400) Unknown link configuration error occurred err-invalid-link-status (401) Unrecognized link status setting err-invalid-link-framing (402) Line framing type not valid for link type err-invalid-link-command (403) Unrecognized link command-action err-invalid-esf-format (405) ESF type not applicable to link type err-invalid-red-timeout (412) Unrecognized red alarm timeout err-invalid-idle-code (413) Unrecognized unused TSs code err-device-in-standby (414) Can't change config for designated Standby device err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
                         optT1E1NationalBits 1.3.6.1.4.1.644.2.4.2.7.1.2.1.11 onebytefield read-write
Enables E1 National S-bits to be set to zero or one. This single byte field can be changed to set the values of the E1 NFA byte in odd frames as depicted below: sa8 sa7 sa6 sa5 sa4 reserved bits --- --- --- --- --- ------------- 1 1 1 1 1 0 0 0 = F8 (default) Values should be entered in Hex. If reserved bits are changed, an error code (427) will be returned in the command status.
                         optT1E1InterNational 1.3.6.1.4.1.644.2.4.2.7.1.2.1.12 onebytefield read-write
Enables InterNational S(i) Spare bit to be set to zero or one. This single byte field can be changed to set the values of the Bit 1 of TS0 G.704 frame as depicted below: reserved bits S(i) -------------------------- ----- 0 0 0 0 0 0 0 1 = 01 (default) Values should be entered in Hex. If reserved bits are changed, an error code (427) will be returned in the command status.
             opticalDiag 1.3.6.1.4.1.644.2.4.2.7.2
                 opticalTUStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.1 no-access
This is the Stm1Oc3 Tributary Unit Status table which consists of an entry for each of the card's 84 links. The total number of entries depends on the number of STM1/OC3 cards in the Node.
                     opticalTUStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.1.1 no-access
The conceptual row of the Stm1Oc3 Tributary Unit Status table. A row in this table cannot be added or deleted, only modified.
                         optTUStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.1.1.1 linkportaddress read-only
This number uniquely identifies a Stm1Oc3 TU link. This number will be used throughout the system to identify a unique resource.
                         optTUStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.1.1.2 integer32 read-only
This number uniquely identifies a Stm1Oc3 TU resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
                         optTUStatusLinkState 1.3.6.1.4.1.644.2.4.2.7.2.1.1.3 integer read-only
Determines the current STM1/OC3 Tributary Unit status of the link. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lof (32) - Loss of Frame los (64) - Loss of Signal red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip sef (8388608) - Severely Errored Frames slip (6291456) - Transmit/Receive Slip underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field value Enumeration: 'rxSlip': 4194304, 'errors': 2147483647, 'lof': 32, 'yel': 2, 'slip': 6291456, 'sef': 8388608, 'ais': 8, 'cfa': 4096, 'los': 64, 'underTest': 1073741824, 'oos': 65535, 'txSlip': 2097152, 'ok': 0, 'red': 2048.
                         optTUStatusErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.4 counter32 read-only
This is the total number of Errored Seconds for the Tributary Unit.
                         optTUStatusAisErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.5 counter32 read-only
This is the total number of TU Alarm Indication Signal Errored Seconds.
                         optTUStatusLopErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.6 counter32 read-only
This is the total number of TU Loss of Pointer Errored Seconds.
                         optTUStatusRdiTUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.7 counter32 read-only
This is the total number of TU Remote Defect Indication Errored Seconds.
                         optTUStatusRfiTUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.8 counter32 read-only
This is the total number of TU Remote Failure Indication Errored Seconds.
                         optTUStatusPSLMErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.9 counter32 read-only
This is the total number of TU Path Signal Label Mismatch Errored Seconds.
                         optTUStatusPSLUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.10 counter32 read-only
This is the total number of TU Path Signal Label Unstable Errored Seconds.
                         optTUStatusErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.11 counter32 read-only
This is the total number of Error-Free seconds for the Tributary Unit.
                 opticalMapperStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.2 no-access
This is the Stm1Oc3 Mapper Status table which consists of an entry for each of the 3 STM1/OC3 Mapper Payloads. The total number of entries depends on the number of STM1/OC3 cards in the Node.
                     opticalMapperStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.2.1 no-access
The conceptual row of the Stm1Oc3 Mapper Status table. A row in this table cannot be added or deleted, only modified.
                         optMapperStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.2.1.1 linkportaddress read-only
This number uniquely identifies a STM1/OC3 Mapper Payload. This number will be used throughout the system to identify a unique resource.
                         optMapperStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.2.1.2 integer32 read-only
This number uniquely identifies a STM1/OC3 Mapper resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
                         optMapperState 1.3.6.1.4.1.644.2.4.2.7.2.2.1.3 integer read-only
This number uniquely identifies the Mapper Payload State. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lop (16) - Loss of Ptr lof (32) - Loss of Frame los (64) - Loss of Signal rdi (128) - Receive Defect Indicator red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip sef (8388608) - Severely Errored Frames slip (6291456) - Transmit/Receive Slip underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field value Enumeration: 'rxSlip': 4194304, 'errors': 2147483647, 'lof': 32, 'yel': 2, 'slip': 6291456, 'sef': 8388608, 'ais': 8, 'cfa': 4096, 'los': 64, 'lop': 16, 'underTest': 1073741824, 'oos': 65535, 'txSlip': 2097152, 'ok': 0, 'rdi': 128, 'red': 2048.
                         optMapperErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.4 counter32 read-only
This is the total number of Errored Seconds for this Mapper Payload.
                         optMapperErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.5 counter32 read-only
This is the total number of Mapper Error Free Seconds.
                         optMapperLoop 1.3.6.1.4.1.644.2.4.2.7.2.2.1.6 integer read-write
Indicates the loopback status of the Stm1Oc3 Mapper for this device.. off (0) - indicates loopback is disabled local (1) - indicates Mapper local data is looped back to itself line (3) - entire Mapper Frame is looped, framing is not regenerated Enumeration: 'local': 1, 'line': 3, 'off': 0.
                         optMapperPathLOPErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.7 counter32 read-only
This is the total number of Mapper Path Loss of Pointer Errored Seconds.
                         optMapperPathAISErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.8 counter32 read-only
This is the total number of Mapper Path Alarm Indication Signal Errored Seconds.
                         optMapperPathRDIErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.9 counter32 read-only
This is the total number of Mapper Path Remote Defect Indication Errored Seconds.
                         optMapperCmdStatus 1.3.6.1.4.1.644.2.4.2.7.2.2.1.10 integer read-write
This is the command status for the Framer Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Mapper Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared The Error Codes used in GET RESPONSE Command (200..799) err-general-test-error (200) Unknown Test request error occurred. err-invalid-loop-type (202) Unrecognized loop selection err-field-cannot-be-set (206) Read-only field was included in SET request err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big Enumeration: 'err-general-test-error': 200, 'clearErrors': 14, 'err-field-cannot-be-set': 206, 'updateTest': 1, 'err-invalid-snmp-var-size': 502, 'clear-successful': 114, 'err-snmp-parse-failed': 500, 'err-invalid-loop-type': 202, 'update-successful': 101, 'ready-for-command': 0, 'err-invalid-snmp-type': 501.
                 opticalTransportStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.3 no-access
This is the Stm1Oc3 Transport Status table which consists of an entry for each of the STM1/OC3 Transport Overhead. The total number of entries depends on the number of Stm1Oc3 cards in the Node.
                     opticalTransportStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.3.1 no-access
The conceptual row of the Stm1Oc3 Transport Status table. A row in this table cannot be added or deleted, only modified.
                         optTransportStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.3.1.1 nestslotaddress read-only
This number uniquely identifies a STM1/OC3 Transport Overhead Nest and Slot number. This number format will be used throughout the system to identify a resource.
                         optTransportStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.3.1.2 integer32 read-only
This number uniquely identifies a STM1/OC3 Transport resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
                         optTransportLaserState 1.3.6.1.4.1.644.2.4.2.7.2.3.1.3 integer read-write
This specifies the State of the Laser Interface. Enumeration: 'on': 1, 'off': 0.
                         optTransportErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.4 counter32 read-only
This is the total number of Errored Seconds for this Transport Overhead.
                         optTransportErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.5 counter32 read-only
This is the total number of Transport Error Free Seconds.
                         optTransportLoop 1.3.6.1.4.1.644.2.4.2.7.2.3.1.6 integer read-write
Indicates the loopback status of the Stm1Oc3 Transport for this device. off (0) - indicates Transport loopback is disabled terminal (1) - The optical line interface transmit driver is looped back to the optical receiver. Ultimately the payload is reflected back to the Switch Fabric and the PCM Highway of the DNX Backplane. facility (2) - The Fiber Optic path is looped back to the facility. pathFacility (3) - The Stm1Oc3 incoming data (Rx) is transmitted back to its source via the Tx path. The bus that interfaces to the mappers is in loopback, and the entire payload is returned to its source with a refreshed frame structure. Enumeration: 'terminal': 1, 'pathFacility': 3, 'off': 0, 'facility': 2.
                         optTransportLineAISErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.7 counter32 read-only
This is the total number of Transport Line Alarm Indication Signal Errored Seconds.
                         optTransportLineRDIErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.8 counter32 read-only
This is the total number of Transport Line Remote Defect Indication Errored Seconds.
                         optTransportLineOOFErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.9 counter32 read-only
This is the total number of Transport Line Out of Frame Errored Seconds.
                         optTransportLineLOFErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.10 counter32 read-only
This is the total number of Transport Line Loss of Frame Errored Seconds.
                         optTransportLineLOSErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.11 counter32 read-only
This is the total number of Transport Line Loss of Signal Errored Seconds.
                         optTransportCmdStatus 1.3.6.1.4.1.644.2.4.2.7.2.3.1.12 integer read-write
This is the command status for the Framer Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Transport Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared The Error Codes used in GET RESPONSE Command (400..799) err-general-test-error (400) Unknown Test request error occurred. err-invalid-loop-type (402) Unrecognized loop selection err-field-cannot-be-set (406) Read-only field was included in SET request err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big Enumeration: 'err-general-test-error': 400, 'clearErrors': 14, 'err-field-cannot-be-set': 406, 'updateTest': 1, 'err-invalid-snmp-var-size': 502, 'clear-successful': 114, 'err-snmp-parse-failed': 500, 'err-invalid-loop-type': 402, 'update-successful': 101, 'ready-for-command': 0, 'err-invalid-snmp-type': 501.
 eriDNXStm1Oc3MIB 1.3.6.1.4.1.644.3.9
The ERI Enterprise MIB Module for the DNX STM1 and OC3 devices.