ELTEX-SMI-ACTUAL: View SNMP OID List / Download MIB
VENDOR: ELTEX ENTERPRISE
Home | MIB: ELTEX-SMI-ACTUAL | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
eltexLtd | 1.3.6.1.4.1.35265 |
The Structure of Management Information for Eltex Networks. |
||
elHardware | 1.3.6.1.4.1.35265.1 |
The root of eltex hardware OIDs. |
||
elSoftware | 1.3.6.1.4.1.35265.2 |
The root of eltex software OIDs. |
||
eltrapGroup | 1.3.6.1.4.1.35265.3 |
The root of eltex traps objects. |
||
mc240TrapTypes | 1.3.6.1.4.1.35265.3.5 | |||
mcTrapExState | 1.3.6.1.4.1.35265.3.5.1 | integer32 | read-only |
state (additional state) |
mcTrapLParam1 | 1.3.6.1.4.1.35265.3.5.2 | integer32 | read-only |
param-1 (slot or index) |
mcTrapLParam2 | 1.3.6.1.4.1.35265.3.5.3 | integer32 | read-only |
param-2 (port or index) |
mcTrapLParam3 | 1.3.6.1.4.1.35265.3.5.4 | integer32 | read-only |
param-3 (other index) |
mcTrapID | 1.3.6.1.4.1.35265.3.5.5 | integer32 | read-only |
ID (pbx trap id) |
mcTrapDescr | 1.3.6.1.4.1.35265.3.5.6 | displaystring | read-only |
Alarm description |
mcTrapRestoredAlarmID | 1.3.6.1.4.1.35265.3.5.7 | integer32 | read-only |
If this restore event then here writed Alarm ID. If this alarm event then mcTrapRestoredAlarmID=0. |
mcTrapSyncType | 1.3.6.1.4.1.35265.3.5.8 | integer32 | read-only |
Type of trap: 0 - Normal; 1 - Journal alarms; 2 - Active alarms |
mcReservedFlag | 1.3.6.1.4.1.35265.3.5.9 | integer32 | read-only |
Reserved flag |
radiusSeqNum | 1.3.6.1.4.1.35265.3.5.10 | integer32 | read-only |
Sequence number of the request |
radiusStatus | 1.3.6.1.4.1.35265.3.5.11 | integer32 | read-only |
Completion status of the request |
radiusTimeout | 1.3.6.1.4.1.35265.3.5.12 | integer32 | read-only |
General timeout (in MS) to complete processing of the request (before receiving the server response or the completion of all attempts) |
radiusSwitchSrv | 1.3.6.1.4.1.35265.3.5.13 | integer32 | read-only |
Quantity indicator switch to the backup server |
radiusTypeResp | 1.3.6.1.4.1.35265.3.5.14 | integer32 | read-only |
The type of the server response |
radiusDescr | 1.3.6.1.4.1.35265.3.5.15 | displaystring | read-only |
Notification description |
fxs72AlarmTraps | 1.3.6.1.4.1.35265.3.6 | |||
fxs72VbatAlarmTrap | 1.3.6.1.4.1.35265.3.6.1 |
Vbat is out of limits (Vbat<38V or Vbat>72V). LParam1 = Vbat voltage |
||
fxs72VringAlarmTrap | 1.3.6.1.4.1.35265.3.6.2 |
Vring1 or Vring2 is out of limits (Vring<100V or Vring>120V). LParam1 = Vring voltage. LParam2 = 1 or 2 |
||
fxs72TemperatureAlarmTrap | 1.3.6.1.4.1.35265.3.6.3 |
Temperature is too high. (Temp>90 deg). LParam1 = temperature value. LParam2 = sensor number |
||
fxs72FanAlarmTrap | 1.3.6.1.4.1.35265.3.6.4 |
Fans are on, but not rotating. LParam1 = fan number |
||
fxs72SSwAlarmTrap | 1.3.6.1.4.1.35265.3.6.5 |
Softswitch became disconnected TAU-MEGACO p1=status (undefined=0, connect=1, disconnect=2) |
||
fxs72PortAlarmTrap | 1.3.6.1.4.1.35265.3.6.6 |
Port Blocked. TAU-SIP Param1 = port number, p2=block cause, Descr = Block cause 0x00 - unknown cause (0x00) 0x01 - leakage current has exceeded the permissible parameters 0x02 - temperature has exceeded the permissible parameters 0x03 - power dissipation has exceeded the permissible parameters 0x04 - reinitialization by changing the input voltage 0x05 - hardware reset 0x06 - low Vbat level 0x07 - FXS port is out of order 0x08 - FXO line is not connected 0x09 - low FXO line current 0x0A - receiver offhook TAU-MEGACO p1=port, p2=cause 1-leakage_current 2-overheating 3-dissipated_power |
||
fxs72BpuAlarmTrap | 1.3.6.1.4.1.35265.3.6.12 |
BPU is NOT available |
||
fxs72TempmeasurementAlarmTrap | 1.3.6.1.4.1.35265.3.6.13 |
Temperature measurement failed. TAU-SIP 2.9 |
||
fxs72LicenseAlarmTrap | 1.3.6.1.4.1.35265.3.6.14 |
TAU-MEGACO 1.2 mcTrapExState: 1 - alarm, no license, 0 - ok license |
||
fxs72updateFwFail | 1.3.6.1.4.1.35265.3.6.20 |
par1 = error type. descr = file + addr + FAIL |
||
fxs72PowerUnitTermAlarm | 1.3.6.1.4.1.35265.3.6.21 |
Power supply unit temperature is out of limit (more than 95 C) |
||
fxs72FanLowSpeedAlarmTrap | 1.3.6.1.4.1.35265.3.6.22 |
Fan rotation speed lower than 1000 rpm |
||
fxs72OkTraps | 1.3.6.1.4.1.35265.3.7 | |||
fxs72VbatOkTrap | 1.3.6.1.4.1.35265.3.7.1 |
Vbat is back to normal. |
||
fxs72VringOkTrap | 1.3.6.1.4.1.35265.3.7.2 |
Vring1 or Vring2 is back to normal. LParam2 = 1 or 2 |
||
fxs72TemperatureOkTrap | 1.3.6.1.4.1.35265.3.7.3 |
Temperature is back to normal. LParam2 = sensor number |
||
fxs72FanOkTrap | 1.3.6.1.4.1.35265.3.7.4 |
Fans are rotating. LParam1 = fan number |
||
fxs72SSwOkTrap | 1.3.6.1.4.1.35265.3.7.5 |
Softswitch status ok. TAU-MEGACO p1=status (undefined=0, connect=1, disconnect=2) |
||
fxs72PortOkTrap | 1.3.6.1.4.1.35265.3.7.6 |
Port unblocked. Param1 = port number, p2=state TAU-MEGACO p1=port, p2=state(ELTEX-FXS72::PortMegacoState) |
||
fxs72VmodeSwitchTrap | 1.3.6.1.4.1.35265.3.7.10 |
Voltage mode has been switched. LParam1 = new mode (1- 60V, 2 - 48V). |
||
fxs72FansSwitchTrap | 1.3.6.1.4.1.35265.3.7.11 |
Fans has been switched on or off. LParam1 = 0 - off, 1 - on. |
||
fxs72BpuOkTrap | 1.3.6.1.4.1.35265.3.7.12 |
BPU is available |
||
fxs72TempmeasurementOkTrap | 1.3.6.1.4.1.35265.3.7.13 |
Temperature measurement is OK. TAU-SIP 2.9 |
||
fxs72LicenseOkTrap | 1.3.6.1.4.1.35265.3.7.14 |
TAU-MEGACO 1.2 mcTrapExState: 1 - alarm, no license, 0 - ok license |
||
fxs72updateFwOk | 1.3.6.1.4.1.35265.3.7.20 |
descr = file + addr + OK |
||
fxs72PowerUnitTermOk | 1.3.6.1.4.1.35265.3.7.21 |
Power supply unit temperature is normal (lower than 95 C) |
||
fxs72FanLowSpeedOkTrap | 1.3.6.1.4.1.35265.3.7.22 |
Fan rotation speed is normal (more than 1000 rpm). |
||
ponTeknovusAlarmTraps | 1.3.6.1.4.1.35265.3.10 | |||
ponTeknovusONTAuthAlarmTrap | 1.3.6.1.4.1.35265.3.10.1 |
Bad registration ONT Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONT') |
||
ponTeknovusUplinkAlarmTrap | 1.3.6.1.4.1.35265.3.10.2 |
Uplink Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down' |
||
ponTeknovusOpticalAlarmTrap | 1.3.6.1.4.1.35265.3.10.3 |
The optical link N (mcTrapLParam1) has no active devices |
||
ponTeknovusFanAlarmTrap | 1.3.6.1.4.1.35265.3.10.4 |
fan stopped. param1 = fan number |
||
ponTeknovusONTConfAlarmTrap | 1.3.6.1.4.1.35265.3.10.5 |
ONT is not configured. Param1 = optical interface number, Descr = mac-address of ONT. |
||
ponTeknovusFlappingAlarmTrap | 1.3.6.1.4.1.35265.3.10.6 |
Period between OpticalAlarmTrap events is less than 30 seconds. Param 1 - link number |
||
ponTeknovusEponAlarmTrap | 1.3.6.1.4.1.35265.3.10.7 |
EPON port failed. Param 1 - link number |
||
ponTeknovusConfigSavedAlarmTrap | 1.3.6.1.4.1.35265.3.10.8 |
Configuration save error. |
||
ponTeknovusFirmwareUpdateAlarmTrap | 1.3.6.1.4.1.35265.3.10.9 |
Firmware update error. |
||
ponTeknovusUserLoginAlarmTrap | 1.3.6.1.4.1.35265.3.10.10 |
User login error **This entry is deprecated** |
||
ponTeknovusRAMAlarmTrap | 1.3.6.1.4.1.35265.3.10.11 |
Ammount of free memory is < 5Mb |
||
ponTeknovusLoginAlarmTrap | 1.3.6.1.4.1.35265.3.10.12 |
Login unsuccessful. Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
ponTeknovusDuplicateMacAlarmTrap | 1.3.6.1.4.1.35265.3.10.14 |
Duplicate mac detected. Param1 = VID, Descr = mac. |
||
ponTeknovusLoadAverageAlarmTrap | 1.3.6.1.4.1.35265.3.10.15 |
Load average exceeded limits. Param1 = 0 - 1 min, 1 - 5 min, 2 - 15 min |
||
ponTeknovusTemperatureAlarmTrap | 1.3.6.1.4.1.35265.3.10.16 |
Temperature is higher than 65 deg. Param1 = temperature value |
||
ponTeknovusONTPortBlockedAlarmTrap | 1.3.6.1.4.1.35265.3.10.17 |
ONT's UNI port blocked. Param1 = port number, Descr = mac-address of ONT |
||
ponTeknovusConfigMigrateAlarmTrap | 1.3.6.1.4.1.35265.3.10.18 |
Config migrate error. Param1 = config type (0 - all, 1 - pon) |
||
ponTeknovusOkTraps | 1.3.6.1.4.1.35265.3.11 | |||
ponTeknovusONTAuthOkTrap | 1.3.6.1.4.1.35265.3.11.1 |
Normal registration ONT Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONT') |
||
ponTeknovusUplinkOkTrap | 1.3.6.1.4.1.35265.3.11.2 |
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up' |
||
ponTeknovusOpticalOkTrap | 1.3.6.1.4.1.35265.3.11.3 |
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices |
||
ponTeknovusFanOkTrap | 1.3.6.1.4.1.35265.3.11.4 |
param1 = fan number |
||
ponTeknovusONTConfOKTrap | 1.3.6.1.4.1.35265.3.11.5 |
ONT is configured. Param1 = optical interface number, Descr = macaddress of ont |
||
ponTeknovusFlappingOkTrap | 1.3.6.1.4.1.35265.3.11.6 |
1 minute passed after last OpticalAlarmTrap. Param 1 - link number |
||
ponTeknovusEponOkTrap | 1.3.6.1.4.1.35265.3.11.7 |
EPON port ok. Param 1 - link number |
||
ponTeknovusConfigSavedOkTrap | 1.3.6.1.4.1.35265.3.11.8 |
Configuration saved. Descr = Configuration saved to flash |
||
ponTeknovusFirmwareUpdateOkTrap | 1.3.6.1.4.1.35265.3.11.9 |
Firmware updated. Descr = Firmware updated |
||
ponTeknovusUserLoginOkTrap | 1.3.6.1.4.1.35265.3.11.10 |
User logged in from CLI. Param1 = privileged/nonprivileged (1/0), Descr = ${username} logged in ** This entry is deprecated. |
||
ponTeknovusRAMOkTrap | 1.3.6.1.4.1.35265.3.11.11 |
Ammount of free memory is > 7Mb |
||
ponTeknovusLoginOkTrap | 1.3.6.1.4.1.35265.3.11.12 |
Login successful. Param1 = privileged/nonprivileged(1/0) Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
ponTeknovusLogoutOkTrap | 1.3.6.1.4.1.35265.3.11.13 |
User logged out. Param1 = privileged/nonprivileged(1/0) Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
ponTeknovusSwitchConfigChangeTrap | 1.3.6.1.4.1.35265.3.11.14 |
Switch configuration has been changed |
||
ponTeknovusLoadAverageOkTrap | 1.3.6.1.4.1.35265.3.11.15 |
Load average is back to normal. Param1 = 0 - 1 min, 1 - 5 min, 2 - 15 min |
||
ponTeknovusTemperatureOkTrap | 1.3.6.1.4.1.35265.3.11.16 |
Temperature is lower than 60 deg. Param1 = temperature value |
||
ponTeknovusONTPortBlockedOkTrap | 1.3.6.1.4.1.35265.3.11.17 |
ONT's UNI port not blocked. Param1 = port number, Descr = mac-address of ONT |
||
ponTeknovusConfigMigrateOkTrap | 1.3.6.1.4.1.35265.3.11.18 |
Config migrate success. Param1 = config type (0 - all, 1 - pon) |
||
ponTeknovusBoardRebootTrap | 1.3.6.1.4.1.35265.3.11.20 |
Board is being rebooted. Descr = |
||
ponTeknovusONTDeconfigureTrap | 1.3.6.1.4.1.35265.3.11.21 |
ONT is being deconfigured (before disconnect). Param1 = pon-channel, Description = mac-address |
||
ponTeknovusONTStateChangedTrap | 1.3.6.1.4.1.35265.3.11.22 |
ONT's state changed. Param1 = pon channel, Param2 = ID ONT, Descr = ELTXhhhhhhhh pon_channel id state |
||
ponTeknovusONTConfigChangedTrap | 1.3.6.1.4.1.35265.3.11.23 |
ONT config changed. Param1 = pon channel, Param2 = ID ONT, Descr = ADD|DEL|EDIT ELTXhhhhhhhh pon_channel id description |
||
ponTeknovusConfigRereadTrap | 1.3.6.1.4.1.35265.3.11.24 |
Config was reread from flash. |
||
pp4AlarmTraps | 1.3.6.1.4.1.35265.3.12 | |||
pp4LinkAlarmTrap | 1.3.6.1.4.1.35265.3.12.1 |
Link is down (Param1 = link number) |
||
pp4AutoNegotiationAlarmTrap | 1.3.6.1.4.1.35265.3.12.2 |
Autonegotiation failed (Param1 = link number) |
||
pp4MemoryAlarmTrap | 1.3.6.1.4.1.35265.3.12.3 |
Running out of free memory (Param1 = current ammount of free memory) |
||
pp4LoadAvgAlarmTrap | 1.3.6.1.4.1.35265.3.12.4 |
Load avg > 95% (Param1 = 1-1min, 2-5 min, 3-15 min, all LAs in description |
||
pp4LoginAlarmTrap | 1.3.6.1.4.1.35265.3.12.5 |
Login failed |
||
pp4LogoutAlarmTrap | 1.3.6.1.4.1.35265.3.12.6 |
Logout failed |
||
pp4SaveAlarmTrap | 1.3.6.1.4.1.35265.3.12.8 |
Save FAIL |
||
pp4LoadCpuAlarmTrap | 1.3.6.1.4.1.35265.3.12.9 |
Load CPU Alarm |
||
pp4DuplicationMacAlarmTrap | 1.3.6.1.4.1.35265.3.12.10 |
Duplication of MAC address on PP4 |
||
pp4LinkFlapAlarmTrap | 1.3.6.1.4.1.35265.3.12.11 |
linkflap on ifindex=param1 |
||
pp4BoardRemoveAlarmTrap | 1.3.6.1.4.1.35265.3.12.13 |
Board removed from slot #par1. board type #par2 |
||
pp4UnitRemoveAlarmTrap | 1.3.6.1.4.1.35265.3.12.14 |
UNIT number par[1] vas removed from position left(par[2]=1) or right(par[2]=0) |
||
pp4PortCounterErrorFoundAlarmTrap | 1.3.6.1.4.1.35265.3.12.16 |
Founded errors for this port-counter |
||
pp4SyncDisallowedAlarmTrap | 1.3.6.1.4.1.35265.3.12.17 |
User didn't set command to allow unit-synchronization |
||
pp4RebootUnitAlarmTrap | 1.3.6.1.4.1.35265.3.12.19 |
|
||
pp4RebootStackAlarmTrap | 1.3.6.1.4.1.35265.3.12.20 |
|
||
pp4RebootFwTimerAlarmTrap | 1.3.6.1.4.1.35265.3.12.21 |
|
||
pp4FwUpdateAlarmTrap | 1.3.6.1.4.1.35265.3.12.22 |
|
||
pp4FwConfirmNeededAlarmTrap | 1.3.6.1.4.1.35265.3.12.23 |
|
||
pp4OkTraps | 1.3.6.1.4.1.35265.3.13 | |||
pp4LinkOkTrap | 1.3.6.1.4.1.35265.3.13.1 |
Link is up (Param1 = link number) |
||
pp4AutoNegotiationOkTrap | 1.3.6.1.4.1.35265.3.13.2 |
Autonegotiation successful (Param1 = link number) |
||
pp4MemoryOkTrap | 1.3.6.1.4.1.35265.3.13.3 |
Ammount of free memory is back to normal |
||
pp4LoadAvgOkTrap | 1.3.6.1.4.1.35265.3.13.4 |
Load avg is back to normal (Param1 = 1-1min, 2-5 min, 3-15 min, all LAs in description |
||
pp4LoginOkTrap | 1.3.6.1.4.1.35265.3.13.5 |
Login OK |
||
pp4LogoutOkTrap | 1.3.6.1.4.1.35265.3.13.6 |
Logout OK |
||
pp4CommitOkTrap | 1.3.6.1.4.1.35265.3.13.7 |
Commit OK |
||
pp4SaveOkTrap | 1.3.6.1.4.1.35265.3.13.8 |
Save OK |
||
pp4LinkFlapEndOkTrap | 1.3.6.1.4.1.35265.3.13.11 |
linkflap End on ifindex=param1 |
||
pp4ConfigChangedOkTrap | 1.3.6.1.4.1.35265.3.13.12 |
Config pp4x Changed |
||
pp4BoardAddOkTrap | 1.3.6.1.4.1.35265.3.13.13 |
New board added to slot #par1. board type #par2 |
||
pp4UnitAddOkTrap | 1.3.6.1.4.1.35265.3.13.14 |
UNIT number par[1] vas added to position left(par[2]=1) or right(par[2]=0) |
||
pp4RoleChangedOkTrap | 1.3.6.1.4.1.35265.3.13.15 |
Now unit number par[1] with position par[2] is Master |
||
pp4PortCounterErrorFreeOkTrap | 1.3.6.1.4.1.35265.3.13.16 |
No errors for this port-counter |
||
pp4SyncDisallowedOkTrap | 1.3.6.1.4.1.35265.3.13.17 |
User set command to allow unit-synchronization |
||
pp4ConfigRestoredOkTrap | 1.3.6.1.4.1.35265.3.13.18 |
timeout for confirm. Config Restored Now |
||
pp4RebootUnitOkTrap | 1.3.6.1.4.1.35265.3.13.19 |
|
||
pp4FwUpdateOkTrap | 1.3.6.1.4.1.35265.3.13.22 |
|
||
mxa32AlarmTraps | 1.3.6.1.4.1.35265.3.14 | |||
mxa32DslLinkAlarmTrap | 1.3.6.1.4.1.35265.3.14.1 |
Adsl port in down state. LParam1 - port number |
||
mxa32EthLinkAlarmTrap | 1.3.6.1.4.1.35265.3.14.2 |
Uplink port in down state. LParam1 - port number |
||
mxa32TempAlarmTrap | 1.3.6.1.4.1.35265.3.14.3 |
Temperature is too high. LParam1 - sensor index: 0(sensor0), 1(sensor1) LParam3 - actual temperature value ['C] |
||
mxa32VoltAlarmTrap | 1.3.6.1.4.1.35265.3.14.4 |
Device voltage is out of range. LParam1 - voltage index: 2(1V), 3(12V), 4(-12V), 5(3.3V), 6(2.5V), 7(1.8V), 8(0.9V), 9(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa32UserLoginTrap | 1.3.6.1.4.1.35265.3.14.5 |
User logIN. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
mxa32OkTraps | 1.3.6.1.4.1.35265.3.15 | |||
mxa32DslLinkOkTrap | 1.3.6.1.4.1.35265.3.15.1 |
Adsl port is up. LParam1 - port number |
||
mxa32EthLinkOkTrap | 1.3.6.1.4.1.35265.3.15.2 |
Uplink port is up. LParam1 - port number |
||
mxa32TempOkTrap | 1.3.6.1.4.1.35265.3.15.3 |
Temperature normalization. LParam1 - sensor index: 0(sensor0), 1(sensor1) LParam3 - actual temperature value ['C] |
||
mxa32VoltOkTrap | 1.3.6.1.4.1.35265.3.15.4 |
Device voltage is in acceptable range. LParam1 - voltage index: 2(1V), 3(12V), 4(-12V), 5(3.3V), 6(2.5V), 7(1.8V), 8(0.9V), 9(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa32UserLogoutTrap | 1.3.6.1.4.1.35265.3.15.5 |
User logOUT. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
mxa64AlarmTraps | 1.3.6.1.4.1.35265.3.16 | |||
mxa64DslLinkAlarmTrap | 1.3.6.1.4.1.35265.3.16.1 |
Adsl port in down state. LParam1 - port number |
||
mxa64EthLinkAlarmTrap | 1.3.6.1.4.1.35265.3.16.2 |
Uplink port in down state. LParam1 - port number |
||
mxa64TempAlarmTrap | 1.3.6.1.4.1.35265.3.16.3 |
Temperature is too high. LParam1 - sensor index: 0(sensor0), 1(sensor1), 2(sensor2), 3(sensor3) LParam3 - actual temperature value ['C] |
||
mxa64VoltAlarmTrap | 1.3.6.1.4.1.35265.3.16.4 |
Device voltage is out of range. LParam1 - voltage index: 4(1V), 5(12V), 6(-12V), 7(3.3V), 8(2.5V), 9(1.8V), 10(0.9V), 11(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa64UserLoginTrap | 1.3.6.1.4.1.35265.3.16.5 |
User login. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
mxa64OkTraps | 1.3.6.1.4.1.35265.3.17 | |||
mxa64DslLinkOkTrap | 1.3.6.1.4.1.35265.3.17.1 |
Adsl port is up. LParam1 - port number |
||
mxa64EthLinkOkTrap | 1.3.6.1.4.1.35265.3.17.2 |
Uplink port is up. LParam1 - port number |
||
mxa64TempOkTrap | 1.3.6.1.4.1.35265.3.17.3 |
Temperature normalization. LParam1 - sensor index: 0(sensor0), 1(sensor1), 2(sensor2), 3(sensor3) LParam3 - actual temperature value ['C] |
||
mxa64VoltOkTrap | 1.3.6.1.4.1.35265.3.17.4 |
Device voltage is in acceptable range. LParam1 - voltage index: 4(1V), 5(12V), 6(-12V), 7(3.3V), 8(2.5V), 9(1.8V), 10(0.9V), 11(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa64UserLogoutTrap | 1.3.6.1.4.1.35265.3.17.5 |
User logout. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
mxa24AlarmTraps | 1.3.6.1.4.1.35265.3.18 | |||
mxa24DslLinkAlarmTrap | 1.3.6.1.4.1.35265.3.18.1 |
Adsl port in down state. LParam1 - port number |
||
mxa24EthLinkAlarmTrap | 1.3.6.1.4.1.35265.3.18.2 |
Uplink port in down state. LParam1 - port number |
||
mxa24TempAlarmTrap | 1.3.6.1.4.1.35265.3.18.3 |
Temperature is too high. LParam1 - sensor index: 0(sensor0), 1(sensor1) LParam3 - actual temperature value ['C] |
||
mxa24VoltAlarmTrap | 1.3.6.1.4.1.35265.3.18.4 |
Device voltage is out of range. LParam1 - voltage index: 2(1V), 3(12V), 4(-12V), 5(3.3V), 6(2.5V), 7(1.8V), 8(0.9V), 9(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa24UserLoginTrap | 1.3.6.1.4.1.35265.3.18.5 |
Device voltage is out of range. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
mxa24OkTraps | 1.3.6.1.4.1.35265.3.19 | |||
mxa24DslLinkOkTrap | 1.3.6.1.4.1.35265.3.19.1 |
Adsl port is up. LParam1 - port number |
||
mxa24EthLinkOkTrap | 1.3.6.1.4.1.35265.3.19.2 |
Uplink port is up. LParam1 - port number |
||
mxa24TempOkTrap | 1.3.6.1.4.1.35265.3.19.3 |
Temperature normalization. LParam1 - sensor index: 0(sensor0), 1(sensor1) LParam3 - actual temperature value ['C] |
||
mxa24VoltOkTrap | 1.3.6.1.4.1.35265.3.19.4 |
Device voltage is in acceptable range. LParam1 - voltage index: 2(1V), 3(12V), 4(-12V), 5(3.3V), 6(2.5V), 7(1.8V), 8(0.9V), 9(1.5V) LParam3 - actual voltage value [mV/10] |
||
mxa24UserLogoutTrap | 1.3.6.1.4.1.35265.3.19.5 |
User logout. LParam1 - the process pid LParam2 - interface number: 1(console), 2(telnet), 3..6(web) |
||
omsOperationAlarmTraps | 1.3.6.1.4.1.35265.3.20 | |||
omsOperationCommandAlarm | 1.3.6.1.4.1.35265.3.20.1 |
mcTrapLParam1 = command |
||
omsOperationOkTraps | 1.3.6.1.4.1.35265.3.21 | |||
omsOperationCommandOk | 1.3.6.1.4.1.35265.3.21.1 |
mcTrapLParam1 = command |
||
elcAlarmTraps | 1.3.6.1.4.1.35265.3.22 | |||
elcONTAuthAlarmTrap | 1.3.6.1.4.1.35265.3.22.1 |
Bad registration ONT Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONT') |
||
elcUplinkAlarmTrap | 1.3.6.1.4.1.35265.3.22.2 |
Uplink Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down' |
||
elcOpticalAlarmTrap | 1.3.6.1.4.1.35265.3.22.3 |
The optical link N (mcTrapLParam1) has no active devices |
||
elcFanAlarmTrap | 1.3.6.1.4.1.35265.3.22.4 |
fan stopped. param1 = fan number |
||
elcONTConfAlarmTrap | 1.3.6.1.4.1.35265.3.22.5 |
ONT is not configured. Param1 = optical interface number, Descr = mac-address of ONT. |
||
elcFlappingAlarmTrap | 1.3.6.1.4.1.35265.3.22.6 |
Period between OpticalAlarmTrap events is less than 30 seconds. Param 1 - link number |
||
elcEponAlarmTrap | 1.3.6.1.4.1.35265.3.22.7 |
EPON port failed. Param 1 - link number |
||
elcConfigSavedAlarmTrap | 1.3.6.1.4.1.35265.3.22.8 |
Configuration save error. |
||
elcFirmwareUpdateAlarmTrap | 1.3.6.1.4.1.35265.3.22.9 |
Firmware update error. |
||
elcUserLoginAlarmTrap | 1.3.6.1.4.1.35265.3.22.10 |
User login error **This entry is deprecated** |
||
elcRAMAlarmTrap | 1.3.6.1.4.1.35265.3.22.11 |
Ammount of free memory is < 5Mb |
||
elcLoginAlarmTrap | 1.3.6.1.4.1.35265.3.22.12 |
Login unsuccessful. Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
elcDuplicateMacAlarmTrap | 1.3.6.1.4.1.35265.3.22.14 |
Duplicate mac detected. Param1 = VID, Descr = mac. |
||
elcLoadAverageAlarmTrap | 1.3.6.1.4.1.35265.3.22.15 |
Load average exceeded limits. Param1 = 0 - 1 min, 1 - 5 min, 2 - 15 min |
||
elcTemperatureAlarmTrap | 1.3.6.1.4.1.35265.3.22.16 |
Temperature is higher than 65 deg. Param1 = temperature value |
||
elcOkTraps | 1.3.6.1.4.1.35265.3.23 | |||
elcONTAuthOkTrap | 1.3.6.1.4.1.35265.3.23.1 |
Normal registration ONT Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONT') |
||
elcUplinkOkTrap | 1.3.6.1.4.1.35265.3.23.2 |
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up' |
||
elcOpticalOkTrap | 1.3.6.1.4.1.35265.3.23.3 |
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices |
||
elcFanOkTrap | 1.3.6.1.4.1.35265.3.23.4 |
param1 = fan number |
||
elcONTConfOKTrap | 1.3.6.1.4.1.35265.3.23.5 |
ONT is configured. Param1 = optical interface number, Descr = macaddress of ont |
||
elcFlappingOkTrap | 1.3.6.1.4.1.35265.3.23.6 |
1 minute passed after last OpticalAlarmTrap. Param 1 - link number |
||
elcEponOkTrap | 1.3.6.1.4.1.35265.3.23.7 |
EPON port ok. Param 1 - link number |
||
elcConfigSavedOkTrap | 1.3.6.1.4.1.35265.3.23.8 |
Configuration saved. Descr = Configuration saved to flash |
||
elcFirmwareUpdateOkTrap | 1.3.6.1.4.1.35265.3.23.9 |
Firmware updated. Descr = Firmware updated |
||
elcUserLoginOkTrap | 1.3.6.1.4.1.35265.3.23.10 |
User logged in from CLI. Param1 = privileged/nonprivileged (1/0), Descr = ${username} logged in ** This entry is deprecated. |
||
elcRAMOkTrap | 1.3.6.1.4.1.35265.3.23.11 |
Ammount of free memory is > 7Mb |
||
elcLoginOkTrap | 1.3.6.1.4.1.35265.3.23.12 |
Login successful. Param1 = privileged/nonprivileged(1/0) Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
elcLogoutOkTrap | 1.3.6.1.4.1.35265.3.23.13 |
User logged out. Param1 = privileged/nonprivileged(1/0) Param1 = protocol (0 - serial, 1 - SSH, 2 - telnet, 3 - http, 4 - https) Descr = login, ip:port |
||
elcSwitchConfigChangeTrap | 1.3.6.1.4.1.35265.3.23.14 |
Switch configuration has been changed |
||
elcLoadAverageOkTrap | 1.3.6.1.4.1.35265.3.23.15 |
Load average is back to normal. Param1 = 0 - 1 min, 1 - 5 min, 2 - 15 min |
||
elcTemperatureOkTrap | 1.3.6.1.4.1.35265.3.23.16 |
Temperature is lower than 60 deg. Param1 = temperature value |
||
smgTraps | 1.3.6.1.4.1.35265.3.29 | |||
smgAlarm | 1.3.6.1.4.1.35265.3.29.1 | |||
smgAlarmConfigTrap | 1.3.6.1.4.1.35265.3.29.1.1 |
Configuration failure (exState 0-ok 3-critical) |
||
smgAlarmSiptNodeTrap | 1.3.6.1.4.1.35265.3.29.1.2 |
SIPT-module alarm (exState 0-ok 3-critical) |
||
smgAlarmMspDevTrap | 1.3.6.1.4.1.35265.3.29.1.3 |
SM-VP module alarm (exState 0-ok 1-alarm) Param1 - module number |
||
smgAlarmLinkSetTrap | 1.3.6.1.4.1.35265.3.29.1.4 |
LinkSet alarm (exState 0-ok 3-critical) Param1 = LinkSet number |
||
smgAlarmStreamTrap | 1.3.6.1.4.1.35265.3.29.1.5 |
Stream alarm (exState 0-ok 2-warning 3-critical) Param1 - stream number Param2=1 - signal loss Param2=2 - remote alarm |
||
smgAlarmSS7LinkTrap | 1.3.6.1.4.1.35265.3.29.1.6 |
SS7-Link alarm (exState 0-ok 1-alarm) Param1 - E1Stream number Param2 - LinkSet number |
||
smgAlarmSyncTrap | 1.3.6.1.4.1.35265.3.29.1.7 |
Synchronization alarm (freerun mode - work with local source) (exState 0-ok 1-alarm 2-warning), param1=1 - local param1=2 - less priority |
||
smgAlarmCdrFtpTrap | 1.3.6.1.4.1.35265.3.29.1.12 |
No connection with FTP server Param1 0 No alarm, 2 - warning (minor alarm. The record was wrong, local CDR-data is less than 5 Mb), 1 - common (major alarm. The record was wrong, local CDR-data is more than 5 Mb and less than 15 Mb), 3 - critical (critical alarm. The record was wrong, local CDR-data is more than 15 Mb) (exState 0-ok 1-alarm 2-warning 3-critical) |
||
smgAlarmMemoryLimitTrap | 1.3.6.1.4.1.35265.3.29.1.13 |
Param2 - free space, Param3 - summary space exState 0-ok, 2-warning (75% busy), 1-alarm (90%), 3-critical (95%) |
||
smgAlarmPowerModuleStateTrap | 1.3.6.1.4.1.35265.3.29.1.14 |
exState 0 - ok, 2 - warning Param1 - PSU number Param2 - PSU state: 0 - OK, 1 - no power supply, 2 - missing |
||
smgAlarmH323NodeTrap | 1.3.6.1.4.1.35265.3.29.1.16 |
No link to H323 adapter alarm (exState 0-ok 1-alarm) |
||
smgAlarmTemperatureTrap | 1.3.6.1.4.1.35265.3.29.1.17 |
Tenperature alarm exState: 0 - ok, 2 - warning (more than 70 deg. Celsius), 1 - alarm (more than 85), 3 - critical-alarm (more than 100) param2 - temp #0 (CPU temp, generates alarm), param3 - temp #1 (RAM temp, for info only) |
||
smgAlarmMaintenanceTrap | 1.3.6.1.4.1.35265.3.29.1.18 |
Maintenance alarm param1: 1 - COT test failed 2 - RLC-packet waiting error 3 - BLA-packet waiting error 4 - UBA-packet waiting error 5 - CGBA-packet waiting error 6 - CGUA-packet waiting error 7 - GRA-packet waiting error 8 - Error while blocking channels (CGBA) - not all of the requested channles were blocked 9 - Error while blocking channels (CGBA) - one of requested channels didn't blocked 10 - Error while blocking channels (CGUA) - not all of the requested channles were blocked 11 - Error while blocking channels (CGUA) - one of requested channels didn't blocked 12 - Error while get power voltage 13 - No free DVO blocks (param2 - subscriber group ID) param2 - E1 stream number, param3 - E1 channel number |
||
smgAlarmSipAccessTrap | 1.3.6.1.4.1.35265.3.29.1.19 |
SIP interface access alarm param1 - SIP interface number |
||
smgUpdateFwFail | 1.3.6.1.4.1.35265.3.29.1.20 |
descr = file + addr + FAIL |
||
smgAlarmProcOverloadTrap | 1.3.6.1.4.1.35265.3.29.1.21 |
Processor overload exState 0-ok, 2-warning (load 90%), 1-alarm (95%) Par3 - CPU mask |
||
smgAlarmFansIdleTrap | 1.3.6.1.4.1.35265.3.29.1.23 |
Fans idle alarm Par1 - fans operational bit-list Par2 - total fans operated Par3 - total fans on board |
||
smgAlarmDriveLimitTrap | 1.3.6.1.4.1.35265.3.29.1.24 |
Drive limit alarm param1: drive_id param2: (percent&0xFF << 8) | (exists & 0xFF) param3: free_size_kB Drive name at description text |
||
smgAlarmSipOptionsQueueOverload | 1.3.6.1.4.1.35265.3.29.1.25 |
SIP OPTIONS queue iverload |
||
smgAlarmCDRFileTrap | 1.3.6.1.4.1.35265.3.29.1.26 |
Error while creating CDR-file state 0 - OK, 1 - commom alarm (can't create CDR file on disk), 3 - critical alarm (can't create CDR file) |
||
smgAlarmMegacoNodeTrap | 1.3.6.1.4.1.35265.3.29.1.27 |
MEGACO-module alarm (exState 0-ok 3-critical) |
||
smgFail2banBlockTrap | 1.3.6.1.4.1.35265.3.29.1.28 |
Fail2ban address block info |
||
smgTrunkGroupCPSTrap | 1.3.6.1.4.1.35265.3.29.1.29 |
TrunkGroup reached CPS warning threshold param1 - TrunkGroup index param2 - CPS-warn threshold value param3 - Detected CPS value |
||
smgDemoLicenseTrap | 1.3.6.1.4.1.35265.3.29.1.30 |
DEMO license status info param1 - Status 1 - inactive (ntp-off) 2 - inactive (ntp-nok) 3 - will expire in less than 72h 4 - will expire in less than 36h 5 - inactive (expired) 6 - inactive (error) |
||
smgAlarmSipDuplicateTrap | 1.3.6.1.4.1.35265.3.29.1.31 |
No SIP interface access alarm param1 - SIP interface number param2 - Destination IP-addr param3 - Destination port |
||
smgAlarmSbcRegistrationExpiredTrap | 1.3.6.1.4.1.35265.3.29.1.50 |
sbc registration expired alarm. (no ok trap). abonent number in description |
||
smgAlarmIpcOverloadTrap | 1.3.6.1.4.1.35265.3.29.1.51 |
IPC overload (exState 0-ok 1-alarm) |
||
smgCallForbiddenTrap | 1.3.6.1.4.1.35265.3.29.1.52 |
Call forbidden info |
||
smgRegForbiddenTrap | 1.3.6.1.4.1.35265.3.29.1.53 |
Registration forbidden info |
||
smgSIPinterfaceTrap | 1.3.6.1.4.1.35265.3.29.1.54 |
SIP interface info |
||
smgReserveSlaveLinkChangedTrap | 1.3.6.1.4.1.35265.3.29.1.55 |
Reserve slave link info param2 = lan status param3 = wan status 0 - unlink, 1 - link |
||
smgReserveSlaveSoftVersionTrap | 1.3.6.1.4.1.35265.3.29.1.56 |
Reserve soft version info |
||
smgSipAttackedTrap | 1.3.6.1.4.1.35265.3.29.1.57 |
SIP attacked info |
||
smgPctlModuleTrap | 1.3.6.1.4.1.35265.3.29.1.58 |
Packet control module info |
||
smgPortScanDetectorTrap | 1.3.6.1.4.1.35265.3.29.1.59 |
Port scan detector info |
||
smgFirewallTrap | 1.3.6.1.4.1.35265.3.29.1.60 |
Firewall info |
||
smgOK | 1.3.6.1.4.1.35265.3.29.2 | |||
smgOkConfigTrap | 1.3.6.1.4.1.35265.3.29.2.1 |
NO Configuration failure |
||
smgOkSiptNodeTrap | 1.3.6.1.4.1.35265.3.29.2.2 |
NO SIPT-module alarm |
||
smgOkMspDevTrap | 1.3.6.1.4.1.35265.3.29.2.3 |
NO SM-VP module alarm Param1 = module number |
||
smgOkLinkSetTrap | 1.3.6.1.4.1.35265.3.29.2.4 |
NO LinkSet alarm Param1 = LinkSet number |
||
smgOkStreamTrap | 1.3.6.1.4.1.35265.3.29.2.5 |
NO Stream alarm Param1 - stream number |
||
smgOkSS7LinkTrap | 1.3.6.1.4.1.35265.3.29.2.6 |
NO SS7-Link alarm: par1 - e1line, par2 - linkset |
||
smgOkSyncTrap | 1.3.6.1.4.1.35265.3.29.2.7 |
NO Synchronization alarm (freerun mode - work with local source) |
||
smgOkCdrFtpTrap | 1.3.6.1.4.1.35265.3.29.2.12 |
FTP server connection in norm |
||
smgOkMemoryLimitTrap | 1.3.6.1.4.1.35265.3.29.2.13 |
No memory alarm Param2 - free space Param3 - summary space |
||
smgOkPowerModuleStateTrap | 1.3.6.1.4.1.35265.3.29.2.14 |
PSU ok Param1 - PSU number Param2 - PSU state: 0 - OK, 1 - no power supply, 2 - missing |
||
smgOkH323NodeTrap | 1.3.6.1.4.1.35265.3.29.2.16 |
Link to H323 adapter is OK |
||
smgOkTemperatureTrap | 1.3.6.1.4.1.35265.3.29.2.17 |
No Temperature alarm Param2 - temp #0 CPU Param3 - temp #1 RAM |
||
smgOkMaintenanceTrap | 1.3.6.1.4.1.35265.3.29.2.18 |
No maintenance alarm param1: MAINTENANCE_ALARM_SS7_COT_FAIL = 1 param2 - E1 stream number, param3 - E1 channel number |
||
smgOkSipAccessTrap | 1.3.6.1.4.1.35265.3.29.2.19 |
No SIP interface access alarm param1 - SIP interface number |
||
smgUpdateFwOk | 1.3.6.1.4.1.35265.3.29.2.20 |
descr = file + addr + OK |
||
smgOkProcOverloadTrap | 1.3.6.1.4.1.35265.3.29.2.21 |
No proc overload |
||
smgOkRebootTrap | 1.3.6.1.4.1.35265.3.29.2.22 |
Software started param1 = (version_major&0xFF) | ((version_minor&0xFF)<<8) | ((version_sub&0xFF)<<16) param2 = version_build param3 = reboot_cause (for SMG2016 only) 0 - power, 1 - software command, 2 - watchdog |
||
smgOkFansIdleTrap | 1.3.6.1.4.1.35265.3.29.2.23 |
Fans idle OK Par1 - fans operational bit-list Par2 - total fans operated Par3 - total fans on board |
||
smgOkDriveLimitTrap | 1.3.6.1.4.1.35265.3.29.2.24 |
Drive limit OK Par1 - drive index Par2 - 1 - drive exist; 0 - removed Par3 - filling percentage Drive name at description text |
||
smgAlarmSipOptionsQueueOk | 1.3.6.1.4.1.35265.3.29.2.25 |
SIP OPTIONS queue is OK |
||
smgOkCDRFileTrap | 1.3.6.1.4.1.35265.3.29.2.26 |
No Error while creating CDR-file state 0 - OK, 1 - commom alarm (can't create CDR file on disk), 3 - critical alarm (can't create CDR file) |
||
smgOkTrunkGroupCPSTrap | 1.3.6.1.4.1.35265.3.29.2.29 |
No CPS warning for the TrunkGroup param1 - TrunkGroup index param2 - CPS-warn threshold value param3 - Detected CPS value |
||
smgOkDemoLicenseTrap | 1.3.6.1.4.1.35265.3.29.2.30 |
DEMO license status info param1 - Status 0 - active |
||
smgOkSipDuplicateTrap | 1.3.6.1.4.1.35265.3.29.2.31 |
SIP interface Duplicate alarm param1 - SIP interface number |
||
smgOkIpcOverloadTrap | 1.3.6.1.4.1.35265.3.29.2.51 |
No IPC overload |
||
smgOkCallForbiddenTrap | 1.3.6.1.4.1.35265.3.29.2.52 |
Call forbidden info |
||
smgOkRegForbiddenTrap | 1.3.6.1.4.1.35265.3.29.2.53 |
Registration forbidden info |
||
smgOkSIPinterfaceTrap | 1.3.6.1.4.1.35265.3.29.2.54 |
SIP interface info |
||
smgOkReserveSlaveLinkChangedTrap | 1.3.6.1.4.1.35265.3.29.2.55 |
Reserve slave link info param2 = lan status param3 = wan status 0 - unlink, 1 - link |
||
smgOkReserveSlaveSoftVersionTrap | 1.3.6.1.4.1.35265.3.29.2.56 |
Reserve soft version info |
||
smgOkSipAttackedTrap | 1.3.6.1.4.1.35265.3.29.2.57 |
SIP attacked info |
||
smgOkPctlModuleTrap | 1.3.6.1.4.1.35265.3.29.2.58 |
Packet control module info |
||
smgOkPortScanDetectorTrap | 1.3.6.1.4.1.35265.3.29.2.59 |
Port scan detector info |
||
smgOkFirewallTrap | 1.3.6.1.4.1.35265.3.29.2.60 |
Firewall info |
||
mccpAlarmTraps | 1.3.6.1.4.1.35265.3.30 | |||
mccpConfigAlarmTrap | 1.3.6.1.4.1.35265.3.30.1 |
config file alarm |
||
mccpSlotAlarmTrap | 1.3.6.1.4.1.35265.3.30.2 |
slot [param1] alarm |
||
mccpLinksetAlarmTrap | 1.3.6.1.4.1.35265.3.30.3 |
SS7 Linkset alarm [param1] |
||
mccpStreamAlarmTrap | 1.3.6.1.4.1.35265.3.30.4 |
Stream alarm at [param1:param2] state=%s [state] |
||
mccpSS7LinkAlarmTrap | 1.3.6.1.4.1.35265.3.30.5 |
SS7 Link alarm at [param1:param2] |
||
mccpSyncAlarmTrap | 1.3.6.1.4.1.35265.3.30.6 |
Low priority sync state or no sync |
||
mccpIntfAlarmTrap | 1.3.6.1.4.1.35265.3.30.7 |
V52-Interface number [param1] Alarm |
||
mccpIntfSlotAlarmTrap | 1.3.6.1.4.1.35265.3.30.8 |
24AK slot [param2] on V52-Interface number [param1] Alarm |
||
mccpSutdownSnmpdAlarmTrap | 1.3.6.1.4.1.35265.3.30.17 |
shutdown snmpd |
||
mccpOkTraps | 1.3.6.1.4.1.35265.3.31 | |||
mccpConfigOkTrap | 1.3.6.1.4.1.35265.3.31.1 |
config file is normal |
||
mccpSlotOkTrap | 1.3.6.1.4.1.35265.3.31.2 |
slot [param1] in work |
||
mccpLinksetOkTrap | 1.3.6.1.4.1.35265.3.31.3 |
SS7 Linkset in work [param1] |
||
mccpStreamOkTrap | 1.3.6.1.4.1.35265.3.31.4 |
Stream alarm at [param1:param2] in work |
||
mccpSS7LinkOkTrap | 1.3.6.1.4.1.35265.3.31.5 |
SS7 Link at [param1:param2] in work |
||
mccpSyncOkTrap | 1.3.6.1.4.1.35265.3.31.6 |
Normal sync state |
||
mccpIntfOkTrap | 1.3.6.1.4.1.35265.3.31.7 |
V52-Interface number [param1] is Normal |
||
mccpIntfSlotOkTrap | 1.3.6.1.4.1.35265.3.31.8 |
24AK slot [param2] on V52-Interface number [param1] is Normal |
||
mccpStartOkTrap | 1.3.6.1.4.1.35265.3.31.16 |
MCCP started |
||
radiusTraps | 1.3.6.1.4.1.35265.3.32 | |||
radiusNotification | 1.3.6.1.4.1.35265.3.32.1 | |||
radiusRequestNotification | 1.3.6.1.4.1.35265.3.32.1.1 |
Notification about request to server |
||
eltexShutdownTrap | 1.3.6.1.4.1.35265.3.99 |
Agent is being normally shutdown. |
||
eltrapNotificationGroup | 1.3.6.1.4.1.35265.3.100 | |||
eltrapObjectGroup | 1.3.6.1.4.1.35265.3.101 | |||
eltrapDepNotificationGroup | 1.3.6.1.4.1.35265.3.103 |