ELTEX-SMI: View SNMP OID List / Download MIB

VENDOR: CROIX ROUGE FRANCAISE


 Home MIB: ELTEX-SMI
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 eltex 1.3.6.1.4.1.34300
The Structure of Management Information for Eltex Networks.
             elHardware 1.3.6.1.4.1.34300.1
The root of eltex hardware OIDs.
             elSoftware 1.3.6.1.4.1.34300.2
The root of eltex software OIDs.
             eltrapGroup 1.3.6.1.4.1.34300.3
The root of eltex traps objects.
                 mc240AlarmTraps 1.3.6.1.4.1.34300.3.3
                     mc240StreamAlarmTrap 1.3.6.1.4.1.34300.3.3.1
mc-240 stream alarm trap. Severity: alert
                     mc240SyncAlarmTrap 1.3.6.1.4.1.34300.3.3.2
mc-240 sync alarm trap. Severity: warning
                     mc240ss7LinkAlarmTrap 1.3.6.1.4.1.34300.3.3.3
mc-240 ss7 link alarm trap. Severity: alert
                     mc240ss7LinksetAlarmTrap 1.3.6.1.4.1.34300.3.3.4
mc-240 ss7 linkset alarm trap. Severity: critical
                     mc240FileAlarmTrap 1.3.6.1.4.1.34300.3.3.5
mc-240 file alarm trap. Severity: critical
                     mc240CardAlarmTrap 1.3.6.1.4.1.34300.3.3.6
mc-240 card alarm trap. Severity: critical
                     mxlDPSAlarmTrap 1.3.6.1.4.1.34300.3.3.7
mxl DSL DP system alarm trap
                     mxlTELEAlarmTrap 1.3.6.1.4.1.34300.3.3.8
mxl DSL DP system alarm trap
                     mc240UPSAlarmTrap 1.3.6.1.4.1.34300.3.3.9
mc240 UPS alarm trap
                     mc240SensAlarmTrap 1.3.6.1.4.1.34300.3.3.10
mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%)
                     dslamLinkDownTrap 1.3.6.1.4.1.34300.3.3.11
dslam link down trap (mcTrapExState = link state, param1 = ADSLport)
                     dslamDSRateAlarmTrap 1.3.6.1.4.1.34300.3.3.12
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
                     dslamUSRateAlarmTrap 1.3.6.1.4.1.34300.3.3.13
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
                     ponONUAuthAlarmTrap 1.3.6.1.4.1.34300.3.3.14
Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
                     ponEthAlarmTrap 1.3.6.1.4.1.34300.3.3.15
Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down'
                     ponOpticalAlarmTrap 1.3.6.1.4.1.34300.3.3.16
The optical link N (mcTrapLParam1) has no active devices
                     dslamOverheatAlarmTrap 1.3.6.1.4.1.34300.3.3.17
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
                     dslamVoltageAlarmTrap 1.3.6.1.4.1.34300.3.3.18
when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
                     dslamSessionAlarmTrap 1.3.6.1.4.1.34300.3.3.19
Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP
                     dslamEthLinkAlarmTrap 1.3.6.1.4.1.34300.3.3.20
Trap sending when switch port link DOWN, mcTrapLParam1 - means port num: for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1; for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
                 mc240OkTraps 1.3.6.1.4.1.34300.3.4
                     mc240StreamOkTrap 1.3.6.1.4.1.34300.3.4.1
mc-240 stream ok trap. Severity: alert
                     mc240SyncOkTrap 1.3.6.1.4.1.34300.3.4.2
mc-240 sync ok trap. Severity: warning
                     mc240ss7LinkOkTrap 1.3.6.1.4.1.34300.3.4.3
mc-240 ss7 link ok trap. Severity: alert
                     mc240ss7LinksetOkTrap 1.3.6.1.4.1.34300.3.4.4
mc-240 ss7 linkset ok trap. Severity: critical
                     mc240FileOkTrap 1.3.6.1.4.1.34300.3.4.5
mc-240 file ok trap. Severity: critical
                     mc240CardOkTrap 1.3.6.1.4.1.34300.3.4.6
mc-240 card trap. Severity: critical
                     mxlDPSOkTrap 1.3.6.1.4.1.34300.3.4.7
mxl DSL DP system alarm trap (normal state)
                     mxlTELEOkTrap 1.3.6.1.4.1.34300.3.4.8
mxl DSL DP system alarm trap (normal state)
                     mc240UPSOkTrap 1.3.6.1.4.1.34300.3.4.9
mc240 UPS alarm trap (normal state)
                     mc240SensOkTrap 1.3.6.1.4.1.34300.3.4.10
mc240 sensor alarm trap (normal state)
                     dslamLinkUpTrap 1.3.6.1.4.1.34300.3.4.11
dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport)
                     dslamDSRateOkTrap 1.3.6.1.4.1.34300.3.4.12
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
                     dslamUSRateOkTrap 1.3.6.1.4.1.34300.3.4.13
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
                     ponONUAuthOkTrap 1.3.6.1.4.1.34300.3.4.14
Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
                     ponEthOkTrap 1.3.6.1.4.1.34300.3.4.15
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up'
                     ponOpticalOkTrap 1.3.6.1.4.1.34300.3.4.16
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices
                     dslamOverheatOkTrap 1.3.6.1.4.1.34300.3.4.17
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
                     dslamVoltageOkTrap 1.3.6.1.4.1.34300.3.4.18
when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
                     dslamSessionOkTrap 1.3.6.1.4.1.34300.3.4.19
Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP
                     dslamEthLinkOkTrap 1.3.6.1.4.1.34300.3.4.20
Trap sending when switch port link UP, mcTrapLParam1 - means port num: for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1; for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
                 mc240TrapTypes 1.3.6.1.4.1.34300.3.5
                     mcTrapExState 1.3.6.1.4.1.34300.3.5.1 integer32 read-only
state (additional state)
                     mcTrapLParam1 1.3.6.1.4.1.34300.3.5.2 integer32 read-only
param-1 (slot or index)
                     mcTrapLParam2 1.3.6.1.4.1.34300.3.5.3 integer32 read-only
param-2 (port or index)
                     mcTrapLParam3 1.3.6.1.4.1.34300.3.5.4 integer32 read-only
param-3 (other index)
                     mcTrapID 1.3.6.1.4.1.34300.3.5.5 integer32 read-only
ID (pbx trap id)
                     mcTrapDescr 1.3.6.1.4.1.34300.3.5.6 displaystring read-only
Alarm description
                     mcTrapRestoredAlarmID 1.3.6.1.4.1.34300.3.5.7 integer32 read-only
If this restore event then here writed Alarm ID. If this alarm event then mcTrapRestoredAlarmID=0.
                     mcTrapSyncType 1.3.6.1.4.1.34300.3.5.8 integer32 read-only
Type of trap: 0 - Normal; 1 - Journal alarms; 2 - Active alarms
                     mcReservedFlag 1.3.6.1.4.1.34300.3.5.9 integer32 read-only
Reserved flag
                 mp800mkAlarmTraps 1.3.6.1.4.1.34300.3.8
                     mp800mkMPStatusAlarmTrap 1.3.6.1.4.1.34300.3.8.1
MP operation error.
                     mp800mkInpParmAlarmTrap 1.3.6.1.4.1.34300.3.8.2
Incorrect input parameters.
                     mp800mkUEPConfAlarmTrap 1.3.6.1.4.1.34300.3.8.3
UEP configuration error.
                     mp800mkTMAlarmTrap 1.3.6.1.4.1.34300.3.8.4
Temperature measurement error.
                     mp800mkACVMAlarmTrap 1.3.6.1.4.1.34300.3.8.5
ACV measurement error.
                     mp800mkIbatMAlarmTrap 1.3.6.1.4.1.34300.3.8.6
Battery current measurement error.
                     mp800mkVbatMAlarmTrap 1.3.6.1.4.1.34300.3.8.7
Battery voltage measurement error.
                     mp800mkVbatChAlarmTrap 1.3.6.1.4.1.34300.3.8.8
Can't change (increase or decrease) battery voltage.
                     mp800mkRlsDevAlarmTrap 1.3.6.1.4.1.34300.3.8.9
Release device is off (battery disconnected).
                     mp800mkDVcellAlarmTrap 1.3.6.1.4.1.34300.3.8.10
Battery cell voltage spread is out of range.
                     mp800mkACVAlarmTrap 1.3.6.1.4.1.34300.3.8.11
AC voltage is out of range.
                     mp800mkBatChargeAlarmTrap 1.3.6.1.4.1.34300.3.8.12
Battery is close to total discharge.
                     mp800mkIloadAlarmTrap 1.3.6.1.4.1.34300.3.8.13
Load current is out of range.
                     mp800mkIbatChAlarmTrap 1.3.6.1.4.1.34300.3.8.14
Battery charge current is too high.
                     mp800mkSuppAlarmTrap 1.3.6.1.4.1.34300.3.8.15
Power supply from battery.
                     mp800mkBatConnAlarmTrap 1.3.6.1.4.1.34300.3.8.16
Battery is disconnected from MPs' output.
                 mp800mkOkTraps 1.3.6.1.4.1.34300.3.9
                     mp800mkMPStatusOkTrap 1.3.6.1.4.1.34300.3.9.1
MP operation OK.
                     mp800mkInpParmOkTrap 1.3.6.1.4.1.34300.3.9.2
Input parameters OK.
                     mp800mkUEPConfOkTrap 1.3.6.1.4.1.34300.3.9.3
UEP configuration OK.
                     mp800mkTMOkTrap 1.3.6.1.4.1.34300.3.9.4
Temperature measurement OK.
                     mp800mkACVMOkTrap 1.3.6.1.4.1.34300.3.9.5
ACV measurement OK.
                     mp800mkIbatMOkTrap 1.3.6.1.4.1.34300.3.9.6
Battery current measurement OK.
                     mp800mkVbatMOkTrap 1.3.6.1.4.1.34300.3.9.7
Battery voltage measurement OK.
                     mp800mkVbatChOkTrap 1.3.6.1.4.1.34300.3.9.8
Battery voltage changing OK.
                     mp800mkRlsDevOkTrap 1.3.6.1.4.1.34300.3.9.9
Release device is on.
                     mp800mkDVcellOkTrap 1.3.6.1.4.1.34300.3.9.10
Battery cell voltage spread is in range.
                     mp800mkACVOkTrap 1.3.6.1.4.1.34300.3.9.11
AC voltage is in range.
                     mp800mkBatChargeOkTrap 1.3.6.1.4.1.34300.3.9.12
Battery charge status is OK.
                     mp800mkIloadOkTrap 1.3.6.1.4.1.34300.3.9.13
Load current is in range.
                     mp800mkIbatChOkTrap 1.3.6.1.4.1.34300.3.9.14
Battery charge current is in range.
                     mp800mkSuppOkTrap 1.3.6.1.4.1.34300.3.9.15
Power supply from MPs.
                     mp800mkBatConnOkTrap 1.3.6.1.4.1.34300.3.9.16
Battery is connected to MPs' output.
                 mp800mkTrapTypes 1.3.6.1.4.1.34300.3.10
                       mp800mkTrapParameter 1.3.6.1.4.1.34300.3.10.1 displaystring read-only
Parameter (V, I, T, etc...)
                       mp800mkTrapValue 1.3.6.1.4.1.34300.3.10.2 displaystring read-only
Value (X mV, Y mA, Z grad, etc...)
                       mp800mkTrapComment 1.3.6.1.4.1.34300.3.10.3 displaystring read-only
Comment (V is out of range [Vmin ... Vmax]!, etc...)
                 omsOperationAlarmTraps 1.3.6.1.4.1.34300.3.20
                       omsOperationCommandAlarm 1.3.6.1.4.1.34300.3.20.1
mcTrapLParam1 = command ; mcTrapLParam2 = filetype mcTrapDescr = Description of operarion: DeviceName, command , tftp host, config filename, status=Error, cause of error
                 omsOperationOkTraps 1.3.6.1.4.1.34300.3.21
                       omsOperationCommandOk 1.3.6.1.4.1.34300.3.21.1
mcTrapLParam1 = command ; mcTrapLParam2 = filetype mcTrapDescr = Description of operarion: DeviceName, command , tftp host, config filename, status=Ok
                 eltrapNotificationGroup 1.3.6.1.4.1.34300.3.100
                 eltrapObjectGroup 1.3.6.1.4.1.34300.3.101