EKINOPS-MGNT2-MIB: View SNMP OID List / Download MIB

VENDOR: EKINOPS SAS


 Home MIB: EKINOPS-MGNT2-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mgnt2 1.3.6.1.4.1.20044.7
MIB for Ekinops 360 management.
     mgnt2SNMPAgentData 1.3.6.1.4.1.20044.7.1
         mgnt2IPmanagment 1.3.6.1.4.1.20044.7.1.1
             mgnt2GigmManagerIpAddressTable 1.3.6.1.4.1.20044.7.1.1.1 no-access
Manager IP address Table.
                 mgnt2GigmManagerIpAddressEntry 1.3.6.1.4.1.20044.7.1.1.1.1 no-access
                     mgnt2GigmManagerIpIndex 1.3.6.1.4.1.20044.7.1.1.1.1.1 integer32 read-only
Index of the IP address of the manager
                     mgnt2GigmManagerIpAddress 1.3.6.1.4.1.20044.7.1.1.1.1.2 ipaddress read-only
IP address of the manager:This OID defines the IP address of the SNMP Manager attached to the Mgnt2
                     mgnt2GigmManagerIpAddressTableRowStatus 1.3.6.1.4.1.20044.7.1.1.1.1.3 rowstatus read-only
The status of this row.
                     mgnt2GigmManagerTrapPort 1.3.6.1.4.1.20044.7.1.1.1.1.4 integer32 read-only
Manager UDP port.
                     mgnt2GigmManagerEnableCtrl 1.3.6.1.4.1.20044.7.1.1.1.1.5 ekionoff read-only
Enabling trap of Ctrl.
                     mgnt2GigmManagerEnableConfig 1.3.6.1.4.1.20044.7.1.1.1.1.6 ekionoff read-only
Enabling trap of config.
                     mgnt2GigmManagerEnableEvent 1.3.6.1.4.1.20044.7.1.1.1.1.7 ekionoff read-only
Enabling trap of event.
                     mgnt2GigmManagerEnableAlarmCrit 1.3.6.1.4.1.20044.7.1.1.1.1.8 ekionoff read-only
Enabling trap of crit alarm.
                     mgnt2GigmManagerEnableAlarmMajor 1.3.6.1.4.1.20044.7.1.1.1.1.9 ekionoff read-only
Enabling trap of major alarm.
                     mgnt2GigmManagerEnableAlarmMinor 1.3.6.1.4.1.20044.7.1.1.1.1.10 ekionoff read-only
Enabling trap of minor alarm.
                     mgnt2GigmManagerRegistrationTimeout 1.3.6.1.4.1.20044.7.1.1.1.1.11 integer32 read-only
Time-out for manager activities.
                     mgnt2GigmManagerEnableAlarmWarning 1.3.6.1.4.1.20044.7.1.1.1.1.12 ekionoff read-only
Enabling trap of warning alarm.
                     mgnt2GigmManagerEnableAlarmIndeterminate 1.3.6.1.4.1.20044.7.1.1.1.1.13 ekionoff read-only
Enabling trap of indeterminate alarm.
             mgnt2GigmBoardIpAddress 1.3.6.1.4.1.20044.7.1.1.2 ipaddress read-write
IP address of the Chassis:This OID defines the IP address of the Mgnt2
             mgnt2GigmIPAddresByDHCP 1.3.6.1.4.1.20044.7.1.1.3 ekistate read-write
IP address retrieved by DHCP:If enabled, the IP address is retrieved by DHCP, in which case changes take effect after a board reset. If disabled the object, mgnt2GigmBoardIpAddress defines the address
             mgnt2GigmNetmask 1.3.6.1.4.1.20044.7.1.1.4 ipaddress read-write
Netmask for the board IP address:This OID defined the IP Subnet mask of the Mgnt2
             mgnt2GigmGatewayAddressTable 1.3.6.1.4.1.20044.7.1.1.5 no-access
Gateway IP address Table: This table contains all the gateway IP addresses.
                 mgnt2GigmGatewayAddressEntry 1.3.6.1.4.1.20044.7.1.1.5.1 no-access
                     mgnt2GigmGatewayIndex 1.3.6.1.4.1.20044.7.1.1.5.1.1 integer32 read-only
Index of the IP address of the gateway
                     mgnt2GigmGatewayAddress 1.3.6.1.4.1.20044.7.1.1.5.1.2 ipaddress read-only
IP address of the gateway :This OID defines the IP address of the gateway attached to the Chassis
                     mgnt2GigmGatewayOrder 1.3.6.1.4.1.20044.7.1.1.5.1.3 integer32 read-only
Gateway priority: This OID defines the priority of the gateway (lower number for higher priority)
             mgnt2GigmSyslog 1.3.6.1.4.1.20044.7.1.1.6 ipaddress read-write
IP address of the syslog server:This OID defines the IP address of the syslog of the Mgnt2
             mgnt2GigmNtpServer 1.3.6.1.4.1.20044.7.1.1.7 ipaddress read-write
IP address of the ntp server:This OID defines the IP address of the ntp server for the Mgnt2
             mgnt2GigmNodeIpAddress 1.3.6.1.4.1.20044.7.1.1.8 ipaddress read-write
Node IP address :This OID defines the Node IP address in node controller mode for the Mgnt2
         mgnt2ModulesManagement 1.3.6.1.4.1.20044.7.1.2
             mgnt2GigmBoardTable 1.3.6.1.4.1.20044.7.1.2.1 no-access
List of PMs plugged in the Chassis
                 mgnt2GigmBoardEntry 1.3.6.1.4.1.20044.7.1.2.1.1 no-access
Row Definition for the PMs table
                     mgnt2IndexBoards 1.3.6.1.4.1.20044.7.1.2.1.1.1 integer32 read-only
Index for PMs table
                     mgnt2Position 1.3.6.1.4.1.20044.7.1.2.1.1.2 integer32 read-only
PM Slot number:This OID gives the slot number in which the PM is plugged
                     mgnt2Name 1.3.6.1.4.1.20044.7.1.2.1.1.3 displaystring read-only
PM name:This OID gives the name of the PM plugged in the Mgnt2
                     mgnt2PortNumber 1.3.6.1.4.1.20044.7.1.2.1.1.4 integer32 read-only
Number of Client Ports:This OID gives the number of client ports on the PM plugged in the Mgnt2
                     mgnt2LineNumber 1.3.6.1.4.1.20044.7.1.2.1.1.5 integer32 read-only
Number of Line Ports:This OID gives the number of line ports on the PM plugged in the Mgnt2
                     mgnt2GroupNumber 1.3.6.1.4.1.20044.7.1.2.1.1.6 integer32 read-only
Number of Groups:This OID gives the number of group of clients on the PM plugged in the Mgnt2
                     mgnt2RootOIDInventory 1.3.6.1.4.1.20044.7.1.2.1.1.7 object identifier read-only
root oid of the inventory leaf of the corresponding PM
                     mgnt2SlotOcc 1.3.6.1.4.1.20044.7.1.2.1.1.8 displaystring read-only
PM Slot occupied:This OID gives the slots taken by this PM
                     mgnt2SubFunctionLabel 1.3.6.1.4.1.20044.7.1.2.1.1.9 displaystring read-only
Sub Function Label: This OID gives the name of the sub function embedded on the Chassis. (applied only on the 100G Chassis)
                     mgnt2SlotStatus 1.3.6.1.4.1.20044.7.1.2.1.1.10 mgnt2slotstatus read-only
Slot Status: This OID gives the status of the slot in the Chassis: See Textual COnvention
             mgnt2GigmSelectedBoard 1.3.6.1.4.1.20044.7.1.2.7 integer read-write
PM Slot number selected:PM selected for further operations in the Ekinops module board tree. This number is the slot number.
         mgnt2GigmMibsTable 1.3.6.1.4.1.20044.7.1.4 no-access
List of MIBs supported by the Chassis SNMPAgent
             mgnt2GigmMibsEntry 1.3.6.1.4.1.20044.7.1.4.1 no-access
Row definition for MIBs table
                 mgnt2IndexMibs 1.3.6.1.4.1.20044.7.1.4.1.1 integer32 read-only
Index for MIBs table
                 mgnt2MibName 1.3.6.1.4.1.20044.7.1.4.1.2 displaystring read-only
MIB name:This OID gives the name of the MIBs supported by the SNMP Agent
                 mgnt2MibPartNumber 1.3.6.1.4.1.20044.7.1.4.1.3 displaystring read-only
MIB Part Number:This OID gives the part number of the MIBs supported by the SNMP Agent
         mgnt2GigmLogicalName 1.3.6.1.4.1.20044.7.1.5 displaystring read-write
Mgnt2 name:This OID defines the name of the Mgnt2
         mgnt2GigmEqptType 1.3.6.1.4.1.20044.7.1.6 integer32 read-only
Equipment type:This OID defines the type of the Equipment
         mgnt2GigmTrapCount 1.3.6.1.4.1.20044.7.1.7
             mgnt2GigmTrapCounter 1.3.6.1.4.1.20044.7.1.7.1 integer32 read-only
Trap counter:This OID counts the number of trap sent
             mgnt2GigmResetTrapCounter 1.3.6.1.4.1.20044.7.1.7.2 ekionoff read-write
Reset trap counter:This OID reset the trap counter to 0
         mgnt2GigmSecurity 1.3.6.1.4.1.20044.7.1.8
             mgnt2GigmRoCommunity 1.3.6.1.4.1.20044.7.1.8.1 displaystring read-write
SNMP Get community:This OID defines the community for the SNMP Get function
             mgnt2GigmRwCommunity 1.3.6.1.4.1.20044.7.1.8.2 displaystring read-write
SNMP Set community:This OID defines the community for the SNMP Set function
             mgnt2GigmTrapCommunity 1.3.6.1.4.1.20044.7.1.8.3 displaystring read-write
SNMP Trap community:This OID defines the community for the SNMP Trap function
         mgnt2GigmTime 1.3.6.1.4.1.20044.7.1.9
             mgnt2GigmCurrentHour 1.3.6.1.4.1.20044.7.1.9.1 integer read-write
Chassis Hour time:This OID defines the hour of the chassis' time
             mgnt2GigmCurrentMinute 1.3.6.1.4.1.20044.7.1.9.2 integer read-write
Chassis Minute time:This OID defines the minute of the chassis' time
             mgnt2GigmCurrentYear 1.3.6.1.4.1.20044.7.1.9.3 integer read-write
Chassis year date:This OID defines the year of the chassis' date
             mgnt2GigmCurrentMonth 1.3.6.1.4.1.20044.7.1.9.4 integer read-write
Chassis month date:This OID defines the month of the chassis' date
             mgnt2GigmCurrentDay 1.3.6.1.4.1.20044.7.1.9.5 integer read-write
Chassis day date:This OID defines the day of the chassis' date
         mgnt2Authentication 1.3.6.1.4.1.20044.7.1.10
               mgnt2GigmRadiusServer 1.3.6.1.4.1.20044.7.1.10.1 ipaddress read-write
IP address of the RADIUS server:This OID defines the IP address of the external RADIUS server for authentication
               mgnt2GigmRadiusPort 1.3.6.1.4.1.20044.7.1.10.2 integer32 read-write
TCP port number of the RADIUS server:This OID defines the TCP port number of the external RADIUS server for authentication
               mgnt2GigmRadiusSecret 1.3.6.1.4.1.20044.7.1.10.3 displaystring read-write
Shared secret of the RADIUS server:This OID defines the shared secret password of the RADIUS server for authentication
               mgnt2GigmLdapHost 1.3.6.1.4.1.20044.7.1.10.4 ipaddress read-write
IP address of the LDAP host:This OID defines the IP address of the external LDAP server for authentication
               mgnt2GigmLdapPort 1.3.6.1.4.1.20044.7.1.10.5 integer32 read-write
TCP port number of the LDAP server:This OID defines the TCP port number of the external LDAP server for authentication
               mgnt2GigmLdapBase 1.3.6.1.4.1.20044.7.1.10.6 displaystring read-write
LDAP base:This OID defines the name of the search base of the LDAP server for authenticationLDAP base name spelled as follows: 'ou=users,ou=network,dc=yourcompany,dc=net'
               mgnt2GigmLdapVersion 1.3.6.1.4.1.20044.7.1.10.7 integer32 read-write
Protocol number in use by the LDAP server:This OID defines the protocol version used by the external LDAP server for authenticationProtocol version used by the external LDAP server for authentication
               mgnt2GigmLdapBindDn 1.3.6.1.4.1.20044.7.1.10.8 displaystring read-write
LDAP Bind DN:This OID defines the login name used to connect into the LDAP server base for authenticationLDAP binddn spelled as follows: 'cn=ldap_admin,dc=yourcompany,dc=net'
               mgnt2GigmLdapBindPw 1.3.6.1.4.1.20044.7.1.10.9 displaystring read-write
Credentials to bind the LDAP server with:This OID defines the credentials to bind the LDAP server with for authenticationCredentials for LDAP access (bindpw)
               mgnt2GigmLdapScope 1.3.6.1.4.1.20044.7.1.10.10 displaystring read-write
Scope for LDAP base search:This OID defines the search scope for an LDAP base search LDAP search scope
               mgnt2GigmLdapPamPasswd 1.3.6.1.4.1.20044.7.1.10.11 displaystring read-write
PAM password handling:This OID defines the way the PAM password is handled for LDAP authentication The 'pam_password' option sould be one of the following: 'clear', 'crypt', 'md5', 'racf', 'exop'
               mgnt2GigmAuthenticationType 1.3.6.1.4.1.20044.7.1.10.12 mgnt2authtypevalues read-write
Authentication type in use
     mgnt2Hardware 1.3.6.1.4.1.20044.7.2
         mgnt2alarms 1.3.6.1.4.1.20044.7.2.1
             mgnt2AlmsynthAlm0 1.3.6.1.4.1.20044.7.2.1.0
                 mgnt2AlmAbsFailure 1.3.6.1.4.1.20044.7.2.1.0.9 ekionoff read-only
Chassis Management Module Failure :This OID indicates that the Chassis Management module is in fail condition ABS_FAILURE other(1) equipmentAlarm (5) (2)
                 mgnt2AlmFansFailure 1.3.6.1.4.1.20044.7.2.1.0.10 ekionoff read-only
Chassis Fan Module Failure :This OID indicates that at least one of the three FAN unit of the FAN module is in fail condition FANS_FAILURE other(1) equipmentAlarm (5) (2)
                 mgnt2AlmDef48a 1.3.6.1.4.1.20044.7.2.1.0.11 ekionoff read-only
Power Input A Present :This OID indicates that there is not input power on the right power connector (A) This alarm indicates if the power input B is present (left power connector) DEF_48A powerProblem (36) equipmentAlarm (5) (2)
                 mgnt2AlmDef48b 1.3.6.1.4.1.20044.7.2.1.0.12 ekionoff read-only
Power Input B Present :This OID indicates that there is not input power on the right power connector (B) This alarm indicates if the power input B is present (right power connector) DEF_48B powerProblem (36) equipmentAlarm (5) (2)
                 mgnt2AlmMgntDefFuseA 1.3.6.1.4.1.20044.7.2.1.0.15 ekionoff read-only
Mgnt Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Management board Status of the MGNT Fuse A MGNT_DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2)
                 mgnt2AlmMgntDefFuseB 1.3.6.1.4.1.20044.7.2.1.0.16 ekionoff read-only
Mgnt Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Management board Status of the MGNT Fuse B MGNT_DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2)
             mgnt2AlmsynthAlm1 1.3.6.1.4.1.20044.7.2.1.1
                 mgnt2AlmNurgVisual 1.3.6.1.4.1.20044.7.2.1.1.1 ekionoff read-only
Minor Chassis Alarm :This OID indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) NURG_VISUAL other(1) other (1) (2)
                 mgnt2AlmUrgVisual 1.3.6.1.4.1.20044.7.2.1.1.2 ekionoff read-only
Major Chassis Alarm :This OID indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) URG_VISUAL other(1) other (1) (2)
                 mgnt2AlmCritVisual 1.3.6.1.4.1.20044.7.2.1.1.3 ekionoff read-only
Critical Chassis Alarm :This OID indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) CRIT_VISUAL other(1) other (1) (2)
                 mgnt2AlmAcknowledge 1.3.6.1.4.1.20044.7.2.1.1.16 ekionoff read-only
Alarm Ack. :This OID indicates the alarms have been acknowledged by the user (locally or remotely) This status indicates the alarms have been acknowledged by the user (locally or remotely) ACKNOWLEDGE other(1) other (1) (2)
             mgnt2AlmboardMgmntSet1 1.3.6.1.4.1.20044.7.2.1.16
                   mgnt2AlmPmSlot1Absent 1.3.6.1.4.1.20044.7.2.1.16.2 ekionoff read-only
PM present in Chassis slot 1 :This OID indicates the presence of a PM in Slot 1 of the Chassis . This status indicates if a PM is detected in slot 1 PM_SLOT1_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot2Absent 1.3.6.1.4.1.20044.7.2.1.16.3 ekionoff read-only
PM present in Chassis slot 2 :This OID indicates the presence of a PM in Slot 2 of the Chassis . This status indicates if a PM is detected in slot 2 PM_SLOT2_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot3Absent 1.3.6.1.4.1.20044.7.2.1.16.4 ekionoff read-only
PM present in Chassis slot 3 :This OID indicates the presence of a PM in Slot 3 of the Chassis . This status indicates if a PM is detected in slot 3 PM_SLOT3_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot4Absent 1.3.6.1.4.1.20044.7.2.1.16.5 ekionoff read-only
PM present in Chassis slot 4 :This OID indicates the presence of a PM in Slot 4 of the Chassis . This status indicates if a PM is detected in slot 4 PM_SLOT4_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot5Absent 1.3.6.1.4.1.20044.7.2.1.16.6 ekionoff read-only
PM present in Chassis slot 5 :This OID indicates the presence of a PM in Slot 5 of the Chassis . This status indicates if a PM is detected in slot 5 PM_SLOT5_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot6Absent 1.3.6.1.4.1.20044.7.2.1.16.7 ekionoff read-only
PM present in Chassis slot 6 :This OID indicates the presence of a PM in Slot 6 of the Chassis . This status indicates if a PM is detected in slot 6 PM_SLOT6_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot7Absent 1.3.6.1.4.1.20044.7.2.1.16.8 ekionoff read-only
PM present in Chassis slot 7 :This OID indicates the presence of a PM in Slot 7 of the Chassis . This status indicates if a PM is detected in slot 7 PM_SLOT7_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot8Absent 1.3.6.1.4.1.20044.7.2.1.16.9 ekionoff read-only
PM present in Chassis slot 8 :This OID indicates the presence of a PM in Slot 8 of the Chassis . This status indicates if a PM is detected in slot 8 PM_SLOT8_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot9Absent 1.3.6.1.4.1.20044.7.2.1.16.10 ekionoff read-only
PM present in Chassis slot 9 :This OID indicates the presence of a PM in Slot 9 of the Chassis . This status indicates if a PM is detected in slot 9 PM_SLOT9_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot10Absent 1.3.6.1.4.1.20044.7.2.1.16.11 ekionoff read-only
PM present in Chassis slot 10 :This OID indicates the presence of a PM in Slot 10 of the Chassis . This status indicates if a PM is detected in slot 10 PM_SLOT10_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot11Absent 1.3.6.1.4.1.20044.7.2.1.16.12 ekionoff read-only
PM present in Chassis slot 11 :This OID indicates the presence of a PM in Slot 11 of the Chassis . This status indicates if a PM is detected in slot 11 PM_SLOT11_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmFanAbsent 1.3.6.1.4.1.20044.7.2.1.16.14 ekionoff read-only
FAN module present in Chassis :This OID indicates the presence of the FAN module in the Chassis. This alarm indicates if the FAN module is detected in the chassis. PM_FAN_ABSENT other(1) equipmentAlarm (5) (2)
             mgnt2AlmboardMgmntSet2 1.3.6.1.4.1.20044.7.2.1.17
                   mgnt2AlmPmSlot12Absent 1.3.6.1.4.1.20044.7.2.1.17.1 ekionoff read-only
PM present in Chassis slot 12 :This OID indicates the presence of a PM in Slot 12 of the Chassis . This status indicates if a PM is detected in slot 12 PM_SLOT12_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot13Absent 1.3.6.1.4.1.20044.7.2.1.17.2 ekionoff read-only
PM present in Chassis slot 13 :This OID indicates the presence of a PM in Slot 13 of the Chassis . This status indicates if a PM is detected in slot 13 PM_SLOT13_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot14Absent 1.3.6.1.4.1.20044.7.2.1.17.3 ekionoff read-only
PM present in Chassis slot 14 :This OID indicates the presence of a PM in Slot 14 of the Chassis . This status indicates if a PM is detected in slot 14 PM_SLOT14_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot15Absent 1.3.6.1.4.1.20044.7.2.1.17.4 ekionoff read-only
PM present in Chassis slot 15 :This OID indicates the presence of a PM in Slot 15 of the Chassis . This status indicates if a PM is detected in slot 15 PM_SLOT15_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot16Absent 1.3.6.1.4.1.20044.7.2.1.17.5 ekionoff read-only
PM present in Chassis slot 16 :This OID indicates the presence of a PM in Slot 16 of the Chassis . This status indicates if a PM is detected in slot 16 PM_SLOT16_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot17Absent 1.3.6.1.4.1.20044.7.2.1.17.6 ekionoff read-only
PM present in Chassis slot 17 :This OID indicates the presence of a PM in Slot 17 of the Chassis . This status indicates if a PM is detected in slot 17 PM_SLOT17_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot18Absent 1.3.6.1.4.1.20044.7.2.1.17.7 ekionoff read-only
PM present in Chassis slot 18 :This OID indicates the presence of a PM in Slot 18 of the Chassis . This status indicates if a PM is detected in slot 18 PM_SLOT18_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot19Absent 1.3.6.1.4.1.20044.7.2.1.17.8 ekionoff read-only
PM present in Chassis slot 19 :This OID indicates the presence of a PM in Slot 19 of the Chassis . This status indicates if a PM is detected in slot 19 PM_SLOT19_ABSENT other(1) other (1) (2)
                   mgnt2AlmPmSlot20Absent 1.3.6.1.4.1.20044.7.2.1.17.9 ekionoff read-only
PM present in Chassis slot 20 :This OID indicates the presence of a PM in Slot 20 of the Chassis . This status indicates if a PM is detected in slot 20 PM_SLOT20_ABSENT other(1) other (1) (2)
             mgnt2AlmfanMgmnt 1.3.6.1.4.1.20044.7.2.1.20
                   mgnt2AlmPbFan1Fail 1.3.6.1.4.1.20044.7.2.1.20.2 ekionoff read-only
Fan Unit #1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #1 is in fail condition PB_FAN1_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmPbFan2Fail 1.3.6.1.4.1.20044.7.2.1.20.3 ekionoff read-only
Fan Unit #2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #2 is in fail condition PB_FAN2_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmPbFan3Fail 1.3.6.1.4.1.20044.7.2.1.20.4 ekionoff read-only
Fan Unit #3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #3 is in fail condition PB_FAN3_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmPbFan4Fail 1.3.6.1.4.1.20044.7.2.1.20.5 ekionoff read-only
Fan Unit #4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #4 is in fail condition PB_FAN4_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmPbFan5Fail 1.3.6.1.4.1.20044.7.2.1.20.6 ekionoff read-only
Fan Unit #5 Failed On Fan Module :This OID indicates a failure on fan 5. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #5 is in fail condition PB_FAN5_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmPbFan6Fail 1.3.6.1.4.1.20044.7.2.1.20.7 ekionoff read-only
Fan Unit #6 Failed On Fan Module :This OID indicates a failure on fan 6. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #6 is in fail condition PB_FAN6_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmFanFilterAbsent 1.3.6.1.4.1.20044.7.2.1.20.16 ekionoff read-only
Dust Filter Presence :This OID indicates that the dust filter is not present This alarm indicates if the Dust Filter is detected in the chassis. FAN_FILTER_ABSENT other(1) equipmentAlarm (5) (2)
             mgnt2AlmfanPwrMgmnt 1.3.6.1.4.1.20044.7.2.1.24
                   mgnt2AlmFanPwrProtOn 1.3.6.1.4.1.20044.7.2.1.24.12 ekionoff read-only
Fan Backup Power :This OID indicates the backup power on the FAN module is switched on FAN_PWR_PROT_ON powerProblem (36) equipmentAlarm (5) (2)
                   mgnt2AlmFanPwrFail1 1.3.6.1.4.1.20044.7.2.1.24.13 ekionoff read-only
Fan Main Power :This OID indicates a failure on the main power of the FAN module This alarm indicates if one of the tow main power convert of the FAN module is in fail condition FAN_PWR_FAIL_1 powerProblem (36) equipmentAlarm (5) (2)
                   mgnt2AlmFanDefFuseA 1.3.6.1.4.1.20044.7.2.1.24.15 ekionoff read-only
Fan Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Fan board Status of the FAN Fuse A FAN_DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2)
                   mgnt2AlmFanDefFuseB 1.3.6.1.4.1.20044.7.2.1.24.16 ekionoff read-only
Fan Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Fan board Status of the FAN Fuse B FAN_DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2)
             mgnt2AlmremoveablefanModuleFail 1.3.6.1.4.1.20044.7.2.1.25
                   mgnt2AlmFan1ModuleAbsent 1.3.6.1.4.1.20044.7.2.1.25.1 ekionoff read-only
FAN Module #1 Present In Chassis :This OID indicates the presence of the FAN module #1 in the Chassis. This alarm indicates if the FAN module #1 is detected in the chassis. FAN1_MODULE_ABSENT other(1) equipmentAlarm (5) (2)
                   mgnt2AlmFan2ModuleAbsent 1.3.6.1.4.1.20044.7.2.1.25.2 ekionoff read-only
FAN Module #2 Present In Chassis :This OID indicates the presence of the FAN module #2 in the Chassis. This alarm indicates if the FAN module #2 is detected in the chassis. FAN2_MODULE_ABSENT other(1) equipmentAlarm (5) (2)
                   mgnt2AlmFan3ModuleAbsent 1.3.6.1.4.1.20044.7.2.1.25.3 ekionoff read-only
FAN Module #3 Present In Chassis :This OID indicates the presence of the FAN module #3 in the Chassis. This alarm indicates if the FAN module #3 is detected in the chassis. FAN3_MODULE_ABSENT other(1) equipmentAlarm (5) (2)
                   mgnt2AlmFan4ModuleAbsent 1.3.6.1.4.1.20044.7.2.1.25.4 ekionoff read-only
FAN Module #4 Present In Chassis :This OID indicates the presence of the FAN module #4 in the Chassis. This alarm indicates if the FAN module #4 is detected in the chassis. FAN4_MODULE_ABSENT other(1) equipmentAlarm (5) (2)
             mgnt2AlmremoveableFanModuleMgmnt 1.3.6.1.4.1.20044.7.2.1.26
                   mgnt2AlmFan1ModuleFail 1.3.6.1.4.1.20044.7.2.1.26.1 ekionoff read-only
FAN Module #1 Failure :This OID indicates a failure on FAN module #1 This alarm indicates if the FAN module #1 is in fail condition FAN1_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmFan2ModuleFail 1.3.6.1.4.1.20044.7.2.1.26.2 ekionoff read-only
FAN Module #2 Failure :This OID indicates a failure on FAN module #2 This alarm indicates if the FAN module #2 is in fail condition FAN2_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmFan3ModuleFail 1.3.6.1.4.1.20044.7.2.1.26.3 ekionoff read-only
FAN Module #3 Failure :This OID indicates a failure on FAN module #3 This alarm indicates if the FAN module #3 is in fail condition FAN3_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
                   mgnt2AlmFan4ModuleFail 1.3.6.1.4.1.20044.7.2.1.26.4 ekionoff read-only
FAN Module #4 Failure :This OID indicates a failure on FAN module #4 This alarm indicates if the FAN module #4 is in fail condition FAN4_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2)
             mgnt2AlmswAlarm1 1.3.6.1.4.1.20044.7.2.1.32
                   mgnt2AlmApiError 1.3.6.1.4.1.20044.7.2.1.32.1 ekionoff read-only
Comm fail between Agent and Transport :This OID indicates a failure detected on the Agent.The failure is located on a communication process with the modules. This alarm indicates if there is a communication mismatch between the MGNT board and a single PM API_ERROR adapterError (2) equipmentAlarm (5) (2)
                   mgnt2AlmFifoCmdError 1.3.6.1.4.1.20044.7.2.1.32.2 ekionoff read-only
SNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs is full This alarm indicates if there is a communication mismatch between the MGNT board and all PM FIFO_CMD_ERROR adapterError (2) equipmentAlarm (5) (2)
                   mgnt2AlmPollingManagerError 1.3.6.1.4.1.20044.7.2.1.32.3 ekionoff read-only
Polling Manager fail :This OID indicates a failure on the Manager polling the PM's This alarm indicates if there is a polling manager failure between the MGNT and the Pm's POLLING_MANAGER_ERROR adapterError (2) equipmentAlarm (5) (2)
             mgnt2AlmapiErrorCode 1.3.6.1.4.1.20044.7.2.1.33 integer read-only
API Error Identification :Error number and description of the abs1AlmApiError object API_ERROR_CODE_1
             mgnt2AlmlogMgmnt 1.3.6.1.4.1.20044.7.2.1.34
                   mgnt2AlmLogFileFull 1.3.6.1.4.1.20044.7.2.1.34.1 ekionoff read-only
Log File Full Alarm :This OID indicates that a log file is full. This file must be cleared to insure correct log function This alarm indicates that one of the log file is Full LOG_FILE_FULL fileError (18) equipmentAlarm (5) (2)
                   mgnt2AlmLog80Full 1.3.6.1.4.1.20044.7.2.1.34.2 ekionoff read-only
Log File Full Warning :This OID indicates that a log file is 80% full. This alarm indicates that one of the log file is 80% Full LOG_80_FULL fileError (18) equipmentAlarm (5) (2)
             mgnt2AlmntpSyncLoss 1.3.6.1.4.1.20044.7.2.1.35
                   mgnt2AlmNtpSyncLoss 1.3.6.1.4.1.20044.7.2.1.35.1 ekionoff read-only
NTP Sync Loss :This OID indicates a loss of synchronisation with the NTP Server. This alarm indicates a loss of synchronisation with the NTP Server. NTP_SYNC_LOSS timingProblem (53) timeDomainViolation (11) (2)
                   mgnt2AlmCpuTempOverRange 1.3.6.1.4.1.20044.7.2.1.35.2 ekionoff read-only
CPU HighTemperature Warning :This OID indicates a temperature over the expected range on the CPU This warning indicates that the temperature of the CPU is reaching its internal limit CPU_TEMP_OVER_RANGE other(1) equipmentAlarm (5) (2)
         mgnt2controls 1.3.6.1.4.1.20044.7.2.2
             mgnt2Ctrlsynth5 1.3.6.1.4.1.20044.7.2.2.5
                 mgnt2CtrlChassisShutdown 1.3.6.1.4.1.20044.7.2.2.5.2 ekionoff read-write
Shut Down of the Management Module :This OID shall be set before shutting down the Chassis power. A delay of 5 sec is necessary between this OID is set and power is shut down. This control initiates a shutdown of the MGNT board,
                 mgnt2CtrlChassisWarmReset 1.3.6.1.4.1.20044.7.2.2.5.3 ekionoff read-write
Reset of the Management Module :This oid triggers a 'warm' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. This control initiates a warm reset of the MGNT board,
                 mgnt2CtrlChassisColdReset 1.3.6.1.4.1.20044.7.2.2.5.4 ekionoff read-write
Cold Reset of the Management Module :This oid triggers a 'cold' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. This control initiates a cold reset of the MGNT board,
             mgnt2CtrltestLed 1.3.6.1.4.1.20044.7.2.2.18
                   mgnt2CtrlGreenLed 1.3.6.1.4.1.20044.7.2.2.18.1 ekionoff read-write
Green Leds Test :This OID switches on all the green Leds as a test feature This control initiates a test leds turning all the LEDs of the chassis to green
                   mgnt2CtrlRedLed 1.3.6.1.4.1.20044.7.2.2.18.2 ekionoff read-write
Red Leds Test :This OID switches on all the red Leds as a test feature This control initiates a test leds turning all the LEDs of the chassis to red
                   mgnt2CtrlLedOff 1.3.6.1.4.1.20044.7.2.2.18.3 ekionoff read-write
Switch off Leds Test :This OID switches off all the Leds as a test feature This control initiates a test leds turning all the LEDs of the complete chassis to OFF
             mgnt2CtrllogFile 1.3.6.1.4.1.20044.7.2.2.19
                   mgnt2CtrlLogFileReset 1.3.6.1.4.1.20044.7.2.2.19.1 ekionoff read-write
Log File Reset :This OID clears all the log files
             mgnt2CtrlmgntSaveConfig 1.3.6.1.4.1.20044.7.2.2.23
                   mgnt2CtrlSaveConfig 1.3.6.1.4.1.20044.7.2.2.23.1 ekionoff read-write
Save Configuration :This OID is used save the configuration related to the enable and mode traps objects This control saves the customer configuration on the MGNT board
             mgnt2CtrlmgntGetGlobalConfig 1.3.6.1.4.1.20044.7.2.2.24
                   mgnt2CtrlGetGlobalConfig 1.3.6.1.4.1.20044.7.2.2.24.1 ekionoff read-write
Get Global Chassis Config :This OID is used to create a global configuration file of the chassis This control creates a single configuration file from PM's and MGNT configuration file into the RAM
             mgnt2CtrlmgntPutGlobalConfig 1.3.6.1.4.1.20044.7.2.2.25
                   mgnt2CtrlPutGlobalConfig 1.3.6.1.4.1.20044.7.2.2.25.1 ekionoff read-write
Put Global Chassis Config :This OID is used to extract a global configuration file of the chassis This control creates configuration files to PM's and MGNT from a single configuration file in the RAM
             mgnt2CtrlmgntAcknowledge 1.3.6.1.4.1.20044.7.2.2.26
                   mgnt2CtrlAcknowledge 1.3.6.1.4.1.20044.7.2.2.26.1 ekionoff read-write
Alarm Ack. :This OID is used to acknowledge the current active alarms of the chassis This control is used to acknowledge the current active alarms of the chassis
         mgnt2config 1.3.6.1.4.1.20044.7.2.3
             mgnt2CfgethPort2 1.3.6.1.4.1.20044.7.2.3.17
                   mgnt2CfgEthPort2Disable 1.3.6.1.4.1.20044.7.2.3.17.1 ekionoff read-write
2nd Ethernet Port Disable :This OID disables 'Ethernet Port 2' .When not required, this port must be disabled in order to prevent unwanted access. Disable the second Ethernet port
                   mgnt2CfgChassisEthernetSplit 1.3.6.1.4.1.20044.7.2.3.17.2 ekionoff read-write
Chassis Ethernet Split :This OID enables the split between the two kendings. Enable/Disable the switch between the two kendings
             mgnt2CfgmgntDccEnable 1.3.6.1.4.1.20044.7.2.3.18 mgnt2dccaccessvalues read-write
DCC Access :This OID selects the mode to enable the DCC on the slots. This Mode enables the Slots 2-4-6-8-10 , or the Slots 2-6-10-14-18. Defines the DCC access on the backplane of the chassis (Slots 2-4-6-8-10 or Slots 2-6-10-14-18)
             mgnt2CfgpmTrapEnable 1.3.6.1.4.1.20044.7.2.3.20
                   mgnt2CfgPmCriticalTrapEn 1.3.6.1.4.1.20044.7.2.3.20.1 ekionoff read-write
Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on critical alarm detected on PM
                   mgnt2CfgPmMajorTrapEn 1.3.6.1.4.1.20044.7.2.3.20.2 ekionoff read-write
Major Alarm Traps Enable :This OID, when set, enables the generation of the major alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on major alarm detected on PM
                   mgnt2CfgPmMinorTrapEn 1.3.6.1.4.1.20044.7.2.3.20.3 ekionoff read-write
Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on minor alarm detected on PM
                   mgnt2CfgPmControlTrapEn 1.3.6.1.4.1.20044.7.2.3.20.5 ekionoff read-write
Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a PM plugged in the chassis In detailed traps mechanism, enable the trap emission on control sent to PM
                   mgnt2CfgPmConfigTrapEn 1.3.6.1.4.1.20044.7.2.3.20.6 ekionoff read-write
Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a PM plugged in the chassis is modified In detailed traps mechanism, enable the trap emission on PM configuration modificatio
             mgnt2CfgmgntTrapEnable 1.3.6.1.4.1.20044.7.2.3.21
                   mgnt2CfgMgntCriticalTrapEn 1.3.6.1.4.1.20044.7.2.3.21.1 ekionoff read-write
MGNT Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on critical alarm detected on MGNT and FAN
                   mgnt2CfgMgntMajorTrapEn 1.3.6.1.4.1.20044.7.2.3.21.2 ekionoff read-write
MGNT Major Traps Enable :This OID, when set, enables the generation of the major alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on major alarm detected on MGNT and FAN
                   mgnt2CfgMgntMinorTrapEn 1.3.6.1.4.1.20044.7.2.3.21.3 ekionoff read-write
MGNT Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on minor alarm detected on MGNT and FAN
                   mgnt2CfgMgntControlTrapEn 1.3.6.1.4.1.20044.7.2.3.21.5 ekionoff read-write
MGNT Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a MGNT plugged in the chassis In detailed traps mechanism, enable the trap emission on control sent to MGNT
                   mgnt2CfgMgntConfigTrapEn 1.3.6.1.4.1.20044.7.2.3.21.6 ekionoff read-write
MGNT Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a MGNT plugged in the chassis is modified In detailed traps mechanism, enable the trap emission on MGNT configuration modification
                   mgnt2CfgMgntEventTrapEn 1.3.6.1.4.1.20044.7.2.3.21.7 ekionoff read-write
MGNT Event Traps Enable :This OID, when set, enables the generation of a trap when an event occurs on the chassis In detailed traps mechanism, enable the trap emission on event detected in the chassis
             mgnt2CfgmgntTrapMode 1.3.6.1.4.1.20044.7.2.3.22 mgnt2trapmodevalues read-write
Traps Mode :This OID is used to define the trap mode (synthetic or detailed mode) Selects the traps mechanism
             mgnt2CfgsyslogEnable 1.3.6.1.4.1.20044.7.2.3.23
                   mgnt2CfgSyslogEventEn 1.3.6.1.4.1.20044.7.2.3.23.1 ekionoff read-write
Syslog Event Enable :This OID, when set, enables the generation of a syslog, when an event has been detected Enable a syslog emission on event detected on the chassis
                   mgnt2CfgSyslogConfigEn 1.3.6.1.4.1.20044.7.2.3.23.2 ekionoff read-write
Syslog Config Enable :This OID, when set, enables the generation of a syslog, when the configuration has been changed. Enable a syslog emission on a configuration change detected on the chassis
                   mgnt2CfgSyslogCtrlEn 1.3.6.1.4.1.20044.7.2.3.23.3 ekionoff read-write
Syslog Control Enable :This OID, when set, enables the generation of a syslog, when a control is set Enable a syslog emission on a control operated on the chassis
                   mgnt2CfgSyslogAlarmEn 1.3.6.1.4.1.20044.7.2.3.23.4 ekionoff read-write
Syslog Alarm Enable :This OID, when set, enables the generation of a syslog, when an alarm occurs Enable a syslog emission on an alarm detected on the chassi
             mgnt2CfgntpTimeZone 1.3.6.1.4.1.20044.7.2.3.24 integer read-write
NTP Time Zone :This OID defines the time zone of the MGNT board for the NTP server This object defines the time zone of the MGNT board (from -12 to +12 hours from the GMT).
             mgnt2CfgpmConfEnable 1.3.6.1.4.1.20044.7.2.3.25
                   mgnt2CfgPmBackupEnable 1.3.6.1.4.1.20044.7.2.3.25.1 ekionoff read-write
Automatic Config Backup :This OID enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modification. This parameter enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modificatio
                   mgnt2CfgPmRestoreEnable 1.3.6.1.4.1.20044.7.2.3.25.2 ekionoff read-write
Automatic Config Restore :This OID enables the automatic PM configuration restore mechanism on PM insertion This parameter enables the automatic PM configuration restore mechanism on PM insertio
             mgnt2CfginactivityTimeout 1.3.6.1.4.1.20044.7.2.3.26 integer read-write
Idle Timeout :This OID defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI. This object defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI
             mgnt2CfgcliAccess 1.3.6.1.4.1.20044.7.2.3.27 mgnt2cliaccessvalues read-write
CLI access :This OID selects the protocol for the remote access to a CLI user. This object defines the protocol used for a remote CLI.
             mgnt2CfgcraftAccess 1.3.6.1.4.1.20044.7.2.3.28 mgnt2craftaccessvalues read-write
CRAFT access :This OID selects the remote access to a CRAFT user. This object defines the access for a remote CRAFT.
             mgnt2CfgperfModes1 1.3.6.1.4.1.20044.7.2.3.29 ekisynchromode read-write
PERF Synchro Source :This OID selects the source of the synchronisation (Internal/External). This object defines the source of the synchronization to operate performance monitoring.
             mgnt2CfgalarmModelActiv 1.3.6.1.4.1.20044.7.2.3.30 mgnt2ackmode read-write
Acknowledge mode :This OID defines the alarms akcnowledge mode This configuration defines the alarms akcnowledge mode
             mgnt2CfgnetworkInput 1.3.6.1.4.1.20044.7.2.3.31 mgnt2netmode read-write
Network input :This OID selects the connection of the Ethernet Network input to either the switches (2) or the daughter board (1) , in this case the MGNT can act as a router This configuration defines the use of the Network input of the front panel
             mgnt2CfgmasterEthMode 1.3.6.1.4.1.20044.7.2.3.32 mgnt2masterethmode read-write
DHCP Master Ethernet Mode :This OID selects the mode of the Master Ethernet in DHCP mode (2) or in Static Mode(1) This configuration defines the use of the Master Ethernet Mode
             mgnt2CfgsubnetMode 1.3.6.1.4.1.20044.7.2.3.33 mgnt2subnetethmode read-write
DHCP Subnet Mode :This OID selects the mode of the Subnet in DHCP mode (2) or in Static Mode(1) This configuration defines the use of the Subnet Mode
             mgnt2CfgrstpMode 1.3.6.1.4.1.20044.7.2.3.34
                   mgnt2CfgRstpEnable 1.3.6.1.4.1.20044.7.2.3.34.1 ekionoff read-write
RSTP Enable :This OID enables the RSTP algorythm This configuration defines the use of RSTP
             mgnt2CfglldpMode 1.3.6.1.4.1.20044.7.2.3.35
                   mgnt2CfgLldpEnable 1.3.6.1.4.1.20044.7.2.3.35.1 ekionoff read-write
LLDP Enable :This OID enables the LLDP algorythm This configuration defines the use of LLDP
             mgnt2CfglogMode 1.3.6.1.4.1.20044.7.2.3.36 mgnt2logfilemode read-write
Log Mode :This OID enables the log file mode This configuration defines the use of the log mod
             mgnt2CfgnodeMode 1.3.6.1.4.1.20044.7.2.3.37
                   mgnt2CfgNodeControllerEnable 1.3.6.1.4.1.20044.7.2.3.37.1 ekionoff read-write
Node Controller Mode :This OID enables the node controller mode This configuration defines the use of the node controller mod
             mgnt2CfgunprivilegedUsersMode 1.3.6.1.4.1.20044.7.2.3.38
                   mgnt2CfgRestrictUnprivilegeUsers 1.3.6.1.4.1.20044.7.2.3.38.1 ekionoff read-write
Restrict Unprivileged Users Rights :This OID enables the restriction of unprivileged user rights to modify their own password This parameter enables the restriction of unprivileged user rights to modify their own password
             mgnt2CfgoscDccLinkUpThreshold 1.3.6.1.4.1.20044.7.2.3.39 integer read-write
OSC/DCC Link Up Thresh. [10-30]s :This OID defines the confirmation threshold to consider an OSC/DCC link as up This parameter defines the confirmation threshold to consider an OSC/DCC link as up
             mgnt2CfgoscDccLinkDownThreshold 1.3.6.1.4.1.20044.7.2.3.40 integer read-write
OSC/DCC Link Down Thresh. [2-3]s :This OID defines the confirmation threshold to consider an OSC/DCC link as down This parameter defines the confirmation threshold to consider an OSC/DCC link as down.
             mgnt2CfgaccountAutoLock 1.3.6.1.4.1.20044.7.2.3.41 integer read-write
Account Auto-Lock [-1 / 1-10] err :This OID defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature. This parameter defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature.
             mgnt2CfgfailCountReset 1.3.6.1.4.1.20044.7.2.3.42 integer read-write
Fail Count Reset [-1 / 1-10] hrs :This OID defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature. This parameter defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature
             mgnt2CfgftpMode 1.3.6.1.4.1.20044.7.2.3.44
                   mgnt2CfgFtpEnable 1.3.6.1.4.1.20044.7.2.3.44.1 ekionoff read-write
FTP Enable :This OID enables the FTP protocol This configuration enables the FTP protocol
             mgnt2CfgtftpMode 1.3.6.1.4.1.20044.7.2.3.45
                   mgnt2CfgTftpEnable 1.3.6.1.4.1.20044.7.2.3.45.1 ekionoff read-write
TFTP Enable :This OID enables the TFTP protocol This configuration enables the TFTP protocol
     mgnt2Traps 1.3.6.1.4.1.20044.7.3
         mgnt2TrapApi 1.3.6.1.4.1.20044.7.3.1
Api error trap with its number
         mgnt2TrapSwError 1.3.6.1.4.1.20044.7.3.2
Chassis software error other API
         mgnt2TrapBoardInserted 1.3.6.1.4.1.20044.7.3.4
A board has been plugged in
         mgnt2TrapBoardRemoved 1.3.6.1.4.1.20044.7.3.5
A board has been plugged out
         mgnt2TrapRestoreConfDone 1.3.6.1.4.1.20044.7.3.6
The Configuration has been restored from the management board
         mgnt2TrapGlobalPowerFail 1.3.6.1.4.1.20044.7.3.8
A global power supply failure has been detected
         mgnt2TrapFanPowerFail 1.3.6.1.4.1.20044.7.3.9
A Fan power supply failure has been detected
         mgnt2TrapGigmPowerFail 1.3.6.1.4.1.20044.7.3.10
A power supply default has been detected in the management board
         mgnt2TrapFanFail 1.3.6.1.4.1.20044.7.3.11
A Fan failure has been detected
         mgnt2TrapLogFileFull 1.3.6.1.4.1.20044.7.3.20
Indicates that the corresponding log file is almost full
         mgnt2TrapAlarm 1.3.6.1.4.1.20044.7.3.30
Indicates that an alarm state has changed
         mgnt2TrapEvent 1.3.6.1.4.1.20044.7.3.31
Indicates that an event has occured
         mgnt2TrapControl 1.3.6.1.4.1.20044.7.3.32
Indicates that a control has been set to the module
         mgnt2TrapConfig 1.3.6.1.4.1.20044.7.3.33
Indicates that a config word has been changed
         mgnt2TrapBoardNumber 1.3.6.1.4.1.20044.7.3.50 integer read-only
This OID gives the slot number of the PM that sent the last trap
         mgnt2TrapSeverity 1.3.6.1.4.1.20044.7.3.51 displaystring read-only
This OID gives the trap severity
         mgnt2TrapSourcePm 1.3.6.1.4.1.20044.7.3.52 displaystring read-only
This OID gives the mnemonic of the pm who sent a trap
         mgnt2TrapSourcePortType 1.3.6.1.4.1.20044.7.3.53 displaystring read-only
This OID gives the type of the port who sent a trap
         mgnt2TrapSourcePortNumber 1.3.6.1.4.1.20044.7.3.54 integer read-only
This OID gives the port number of the PM that sent the last trap
         mgnt2TrapSourceLabel 1.3.6.1.4.1.20044.7.3.55 displaystring read-only
This OID gives the label of the alarm who sent a trap
         mgnt2TrapSourceValue 1.3.6.1.4.1.20044.7.3.56 ekionoff read-only
This OID gives the value of the alarm who sent a trap
         mgnt2TrapEventLabel 1.3.6.1.4.1.20044.7.3.57 displaystring read-only
This OID gives the label of the event
         mgnt2TrapNodeControllerIpAddress 1.3.6.1.4.1.20044.7.3.58 ipaddress read-only
This OID gives the IP address of the Node Controller
         mgnt2TrapChassisId 1.3.6.1.4.1.20044.7.3.59 displaystring read-only
This OID gives the chassis ID
     mgnt2SoftwareManagement 1.3.6.1.4.1.20044.7.4
         mgnt2DwlUploadingTable 1.3.6.1.4.1.20044.7.4.1 no-access
SNMP Agent SW packages in ram: List of the SNMP agent software packages available in /ram for download on the Chassis managment module flash
             mgnt2DwlUploadingEntry 1.3.6.1.4.1.20044.7.4.1.1 no-access
Row definition for the package uploading table
                 mgnt2IndexUpload 1.3.6.1.4.1.20044.7.4.1.1.1 integer32 read-only
Index for uploading table
                 mgnt2DwlUploadFileName 1.3.6.1.4.1.20044.7.4.1.1.2 displaystring read-only
Package filename in RAM:This OID gives the name of the SNMP agent software packages in RAM
                 mgnt2ImmediateReplacement 1.3.6.1.4.1.20044.7.4.1.1.3 ekistate read-write
Immediat Agent Replacement:This OID indicates to switch to selected SNMP agent immediately or after reset of the MGNT2
                 mgnt2FileUpload 1.3.6.1.4.1.20044.7.4.1.1.4 ekionoff read-write
Agent File Upload:This OID validates the upload of the SNMP agent from RAM to FLASH
                 mgnt2DeletePackageFromRam 1.3.6.1.4.1.20044.7.4.1.1.5 ekionoff read-write
Delete Package from RAM:This OID requests to delete the SNMP Agent SW package from RAM
                 mgnt2FlashingInProgress 1.3.6.1.4.1.20044.7.4.1.1.6 ekionoff read-only
Flashing in Progress:This OID indicates whether there is a file upload to FLASH in progress
         mgnt2DwlPackageTable 1.3.6.1.4.1.20044.7.4.2 no-access
List of SNMP agent software packages present in flash memory
             mgnt2DwlPackageEntry 1.3.6.1.4.1.20044.7.4.2.1 no-access
Row definition for the package management table
                 mgnt2IndexPackage 1.3.6.1.4.1.20044.7.4.2.1.1 integer32 read-only
Index for package management table
                 mgnt2DwlPackageFileName 1.3.6.1.4.1.20044.7.4.2.1.2 displaystring read-only
Package File name in FLASH:This OID gives the name of the SNMP agent software package in FLASH
                 mgnt2ExtractedPack 1.3.6.1.4.1.20044.7.4.2.1.3 ekionoff read-only
Extracted SNMP agent software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted
                 mgnt2SwitchTo 1.3.6.1.4.1.20044.7.4.2.1.4 ekionoff read-write
Switch to package:This OID activates the SNMP Agent Software package
                 mgnt2Immediate 1.3.6.1.4.1.20044.7.4.2.1.5 ekionoff read-write
Immediate SNMP agent activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset
                 mgnt2DeletePackageFromFlash 1.3.6.1.4.1.20044.7.4.2.1.6 ekionoff read-write
Delete package from FLASH:This OID deletes the SNMP agent software package from the FLASH
                 mgnt2PackageExtractionInProgress 1.3.6.1.4.1.20044.7.4.2.1.7 ekionoff read-only
Package extraction in progress:This OID indicates that a SNMP agent software activation is in progress
         mgnt2DwlUploadingTableUpdate 1.3.6.1.4.1.20044.7.4.3 ekionoff read-write
Uploading Table update:This OID updates the contents of the uploading table
         mgnt2LoadPMTable 1.3.6.1.4.1.20044.7.4.4 no-access
List of the PM module software files (GW/SW) present on the repository
             mgnt2LoadPMEntry 1.3.6.1.4.1.20044.7.4.4.1 no-access
Row definition for the LOAD article table
                 mgnt2LoadPMIndex 1.3.6.1.4.1.20044.7.4.4.1.1 integer32 read-only
Index for Load article table
                 mgnt2LoadFileName 1.3.6.1.4.1.20044.7.4.4.1.2 displaystring read-only
PM Upgrade filename:This OID gives the name of the file
                 mgnt2LoadFileType 1.3.6.1.4.1.20044.7.4.4.1.3 ekiloadgwsw read-only
PM upgrade file type:This OID gives the type of file (gateware or software)
                 mgnt2LoadState 1.3.6.1.4.1.20044.7.4.4.1.4 ekiloadstate read-only
PM upgrade status:This OID gives the status of the selected Load file
                 mgnt2LoadModuleNumber 1.3.6.1.4.1.20044.7.4.4.1.5 integer32 read-write
PM ugprade target:This OID defines the slot number of the PM to upgrade
                 mgnt2LoadResetMethod 1.3.6.1.4.1.20044.7.4.4.1.6 ekiloadpermutmethod read-write
PM upgrade reset method:This OID defines the reset method (manual, immediate or scheduled)
                 mgnt2LoadResetMode 1.3.6.1.4.1.20044.7.4.4.1.7 ekiloadpermutmode read-write
PM upgrade reset mode:This OID defines the type of reset (cold or warm)
                 mgnt2LoadBankNumber 1.3.6.1.4.1.20044.7.4.4.1.8 integer32 read-write
PM upgrade bank number:This OID defines the target bank number in the PM's flash
                 mgnt2LoadDownloadProgress 1.3.6.1.4.1.20044.7.4.4.1.9 integer32 read-only
PM upgrade progress:This OID gives the upgrade progress (percentage)
                 mgnt2LoadTransfer 1.3.6.1.4.1.20044.7.4.4.1.10 ekionoff read-write
PM upgrade transfer:This OID launchs the transfer of the associated file to the selected PM's flash
                 mgnt2LoadDelete 1.3.6.1.4.1.20044.7.4.4.1.11 ekionoff read-write
PM upgrade delete file:This OID deletes the associated file from the RAM of the management board
         mgnt2LoadPMTableUpdate 1.3.6.1.4.1.20044.7.4.5 ekionoff read-write
Load PM Table update:This OID updates the contents of the Load table
         mgnt2DwlEkicraftPkgTable 1.3.6.1.4.1.20044.7.4.6 no-access
List of Ekicraft software packages present in flash memory
             mgnt2DwlEkicraftPkgEntry 1.3.6.1.4.1.20044.7.4.6.1 no-access
Row definition for the package management table
                 mgnt2IndexEkicraftPkg 1.3.6.1.4.1.20044.7.4.6.1.1 integer32 read-only
Index for Ekicraft package management table
                 mgnt2DwlEkicraftPkgFileName 1.3.6.1.4.1.20044.7.4.6.1.2 displaystring read-only
Package File name in FLASH:This OID gives the name of the Ekicraft software package in FLASH
                 mgnt2DwlEkicraftExtractedPack 1.3.6.1.4.1.20044.7.4.6.1.3 ekionoff read-only
Extracted Ekicraft software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted
                 mgnt2DwlEkicraftSwitchTo 1.3.6.1.4.1.20044.7.4.6.1.4 ekionoff read-write
Switch to package:This OID activates the Ekicraft Software package
                 mgnt2DwlEkicraftImmediate 1.3.6.1.4.1.20044.7.4.6.1.5 ekionoff read-write
Immediate Ekicraft activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset
                 mgnt2DeleteEkicraftPkgFromFlash 1.3.6.1.4.1.20044.7.4.6.1.6 ekionoff read-write
Delete package from FLASH:This OID deletes the Ekicraft software package from the FLASH
                 mgnt2EkicraftPkgExtractionInProgress 1.3.6.1.4.1.20044.7.4.6.1.7 ekionoff read-only
Package extraction in progress:This OID indicates that an Ekicraft activation is in progress
     mgnt2ConfigManagement 1.3.6.1.4.1.20044.7.5
         mgnt2CnfUploadConfigFilesTable 1.3.6.1.4.1.20044.7.5.1 no-access
List of configuration files uploaded to RAM
             mgnt2CnfUploadConfigFilesEntry 1.3.6.1.4.1.20044.7.5.1.1 no-access
Row definition for the package uploading table
                 mgnt2CnfUploadConfigIndex 1.3.6.1.4.1.20044.7.5.1.1.1 integer32 read-only
Index of config files
                 mgnt2CnfConfigFileName 1.3.6.1.4.1.20044.7.5.1.1.2 displaystring read-only
Configuration filename in RAM:This OID gives the name of the configuration file in RAM
                 mgnt2CnfConfigSlot 1.3.6.1.4.1.20044.7.5.1.1.3 integer32 read-write
Configuration target:This OID defines the target slot number for the configuration file
                 mgnt2CnfConfigUpload 1.3.6.1.4.1.20044.7.5.1.1.4 ekionoff read-write
Configuration Upload:This OID uploads the configuration file to the specified slot number in the PM FLASH
                 mgnt2CnfDeleteConfigFile 1.3.6.1.4.1.20044.7.5.1.1.5 ekionoff read-write
Configuration delete from RAM:This OID deletes the configuration file from RAM
         mgnt2CnfManageConfigFilesTable 1.3.6.1.4.1.20044.7.5.2 no-access
List of configuration files uploaded to RAM
             mgnt2CnfManageConfigFilesEntry 1.3.6.1.4.1.20044.7.5.2.1 no-access
Row definition for the package uploading table
                 mgnt2CnfManageConfigIndex 1.3.6.1.4.1.20044.7.5.2.1.1 integer32 read-only
Index of config file slots
                 mgnt2CnfManageConfigFileID 1.3.6.1.4.1.20044.7.5.2.1.2 displaystring read-write
Configuration file ID in FLASH:This OID gives the ID of the configuration file in MGNT2 FLASH
                 mgnt2CnfManageConfigFileName 1.3.6.1.4.1.20044.7.5.2.1.3 displaystring read-write
Configuration file name in FLASH:This OID gives the name of the configuration file in MGNT2 FLASH
                 mgnt2CnfModuleSlotNumber 1.3.6.1.4.1.20044.7.5.2.1.4 integer32 read-write
Configuration target:This OID defines the target module slot number for the configuration file
                 mgnt2CnfBackupConfig 1.3.6.1.4.1.20044.7.5.2.1.5 ekionoff read-write
Configuration backup:This OID backups the configuration of the specified module to the selected file in MGNT2 FLASH
                 mgnt2CnfRestoreConfig 1.3.6.1.4.1.20044.7.5.2.1.6 ekionoff read-write
Configuration Restore:This OID restores the configuration of the specified module from the selected file in MGNT2 FLASH
                 mgnt2CnfExportConfig 1.3.6.1.4.1.20044.7.5.2.1.7 ekionoff read-write
Configuration Export:This OID exports the selected file in MGNT2 FLASH to a file in RAM
                 mgnt2CnfDeleteConfig 1.3.6.1.4.1.20044.7.5.2.1.8 ekionoff read-write
Configuration delete from FLASH:This OID deletes the configuration file from the MGNT2 FLASH
     mgnt2RemoteInventory 1.3.6.1.4.1.20044.7.6
         mgnt2RinvHwPlatform 1.3.6.1.4.1.20044.7.6.1 displaystring read-write
Chassis Hardware inventory:This OID gives the Hardware inventory of the Mgnt2 management module
         mgnt2RinvSoftwarePackage 1.3.6.1.4.1.20044.7.6.2 displaystring read-write
Chassis Software package inventory:this OID gives the Software package inventory of the Mgnt2 management module
         mgnt2RinvGateware 1.3.6.1.4.1.20044.7.6.3 displaystring read-write
Chassis Gateware inventory:This OID gives the gateware inventory of the Mgnt2 management module
         mgnt2RinvAgent 1.3.6.1.4.1.20044.7.6.4 displaystring read-write
Chassis Software inventory:This OID gives the software inventory of the Mgnt2 management module
         mgnt2RinvCraft 1.3.6.1.4.1.20044.7.6.5 displaystring read-write
Chassis Craft inventory:This OID gives the craft inventory of the Mgnt2 management module
         mgnt2RinvLinux 1.3.6.1.4.1.20044.7.6.6 displaystring read-write
Chassis Linux inventory:This OID gives the linux inventory of the Mgnt2 management module
         mgnt2GigmPlugInTable 1.3.6.1.4.1.20044.7.6.7 no-access
List of Plug-ins present
             mgnt2GigmPlugInEntry 1.3.6.1.4.1.20044.7.6.7.1 no-access
Row Definition for the Plug-ins table
                 mgnt2IndexPlugIns 1.3.6.1.4.1.20044.7.6.7.1.1 integer32 read-only
Index for PMs table
                 mgnt2PlugInRinv 1.3.6.1.4.1.20044.7.6.7.1.2 displaystring read-only
Plug-in RI:This OID gives the remote inventory of the plug-in
                 mgnt2PollingPresent 1.3.6.1.4.1.20044.7.6.7.1.3 ekipluginstate read-only
Polling present:This OID gives the presence of the polling plug-in
                 mgnt2SnmpPresent 1.3.6.1.4.1.20044.7.6.7.1.4 ekipluginstate read-only
Snmp present:This OID gives the presence of the snmp plug-in
         mgnt2RinvBackpanel 1.3.6.1.4.1.20044.7.6.8 displaystring read-write
Backpanel inventory:This OID gives the Backpanel inventory of the chassis
         mgnt2RinvFan 1.3.6.1.4.1.20044.7.6.9 displaystring read-write
Fan inventory:This OID gives the fan inventory of the chassis
         mgnt2RinvUboot 1.3.6.1.4.1.20044.7.6.10 displaystring read-write
U-Boot inventory:This OID gives the U-Boot inventory
     mgnt2ErrorCounters 1.3.6.1.4.1.20044.7.7
         mgnt2GigmErrorCounterTable 1.3.6.1.4.1.20044.7.7.1 no-access
List of error counters
             mgnt2GigmErrorCounterEntry 1.3.6.1.4.1.20044.7.7.1.1 no-access
Row Definition for the error counters table
                 mgnt2IndexErrorCounter 1.3.6.1.4.1.20044.7.7.1.1.1 integer32 read-only
Index for error counters table
                 mgnt2ErrorCounterSlotNumber 1.3.6.1.4.1.20044.7.7.1.1.2 integer32 read-only
Slot number:This OID gives the slot number for the corresponding counter
                 mgnt2ErrorCounterValue 1.3.6.1.4.1.20044.7.7.1.1.3 integer32 read-only
Count value:This OID gives the value of the error counter
         mgnt2GigmResetErrorCounters 1.3.6.1.4.1.20044.7.7.2 ekionoff read-write
Reset error counters:This OID reset the error counters to 0
     mgnt2Perf 1.3.6.1.4.1.20044.7.8
         mgnt2PerfCapabilityTable 1.3.6.1.4.1.20044.7.8.1 no-access
List of Perf capability of PMs plugged in the Chassis
             mgnt2PerfCapabilityEntry 1.3.6.1.4.1.20044.7.8.1.1 no-access
Row Definition for the Perf capability table
                 mgnt2PerfCapIndexBoards 1.3.6.1.4.1.20044.7.8.1.1.1 integer32 read-only
Index for Perf cap table
                 mgnt2PerfCapPosition 1.3.6.1.4.1.20044.7.8.1.1.2 integer32 read-only
PM Slot number:This OID gives the slot number in which the PM is plugged
                 mgnt2PerfCapName 1.3.6.1.4.1.20044.7.8.1.1.3 displaystring read-only
PM name:This OID gives the name of the PM plugged in the Mgnt2
                 mgnt2PerfCapStatus 1.3.6.1.4.1.20044.7.8.1.1.4 ekionoff read-only
Status of the perf cap:This OID gives the capability of the pm to do performance
                 mgnt2PerfCapOidEnable 1.3.6.1.4.1.20044.7.8.1.1.5 object identifier read-only
OID of the object perf enable:This OID gives the OID of the perf enable object of the correspondind mib of the module
         mgnt2GigmPerf15minSync 1.3.6.1.4.1.20044.7.8.2 ekionoff read-write
15 min sync perf : this oid send a 15min sync to all modules
         mgnt2GigmPerf24hSync 1.3.6.1.4.1.20044.7.8.3 ekionoff read-write
15 min sync perf : this oid send a 24h sync to all modules
         mgnt2PerfResyncNMS 1.3.6.1.4.1.20044.7.8.4 mgnt2perfresyncvalues read-write
Resync Perf : this oid allows to create an historical perf file for all modules