ED-1032-MIB: View SNMP OID List / Download MIB

VENDOR: BROCADE


 Home MIB: ED-1032-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mcData 1.3.6.1.4.1.289
         commDev 1.3.6.1.4.1.289.2
             fibreChannel 1.3.6.1.4.1.289.2.1
                 fcSwitch 1.3.6.1.4.1.289.2.1.1
                     ed_1032 1.3.6.1.4.1.289.2.1.1.1
                         ed1032Sys 1.3.6.1.4.1.289.2.1.1.1.1
                             ed1032SysCurrentDate 1.3.6.1.4.1.289.2.1.1.1.1.1 displaystring read-only
The current date information.
                             ed1032SysBootDate 1.3.6.1.4.1.289.2.1.1.1.1.2 displaystring read-only
The date and time of the last IPL
                             ed1032SysFirmwareVersion 1.3.6.1.4.1.289.2.1.1.1.1.3 displaystring read-only
The current version of the firmware.
                             ed1032SysTypeNum 1.3.6.1.4.1.289.2.1.1.1.1.4 displaystring read-only
This object identifies ASCII type number for the unit.
                             ed1032SysModelNum 1.3.6.1.4.1.289.2.1.1.1.1.5 displaystring read-only
This object identifies ASCII model number for the unit.
                             ed1032SysMfg 1.3.6.1.4.1.289.2.1.1.1.1.6 displaystring read-only
This object identifies ASCII manufacturer for the unit.
                             ed1032SysPlantOfMfg 1.3.6.1.4.1.289.2.1.1.1.1.7 displaystring read-only
This object identifies ASCII plant of manufacturer for the unit.
                             ed1032SysSeqNum 1.3.6.1.4.1.289.2.1.1.1.1.8 displaystring read-only
This object identifies ASCII sequence number for the unit.
                             ed1032SysEcLevel 1.3.6.1.4.1.289.2.1.1.1.1.9 displaystring read-only
This object identifies ASCII EC level ID for the unit.
                             ed1032SysOemSerialNum 1.3.6.1.4.1.289.2.1.1.1.1.10 displaystring read-only
This object identifies ASCII OEM serial number for the unit.
                             ed1032SysOperStatus 1.3.6.1.4.1.289.2.1.1.1.1.11 ed1032sysoperstatus read-only
The current operational status of the switch. The values are defined as follow: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5).
                             ed1032SysState 1.3.6.1.4.1.289.2.1.1.1.1.12 ed1032sysstate read-only
If the edOperStatus of the switch is operational, the switch will be in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4).
                             ed1032SysAdmStatus 1.3.6.1.4.1.289.2.1.1.1.1.13 integer read-write
The desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The desired administrative status are online(1) and offline(2). The online means setting the switch to be accessible by an external Fibre Channel port, and offline means setting the switch to be inaccessible. Enumeration: 'offline': 2, 'online': 1.
                         ed1032Fru 1.3.6.1.4.1.289.2.1.1.1.2
                             ed1032FruTable 1.3.6.1.4.1.289.2.1.1.1.2.1 no-access
A table that contains one entry for each module.
                                 ed1032FruEntry 1.3.6.1.4.1.289.2.1.1.1.2.1.1 no-access
An entry containing the service parameters of the module.
                                     ed1032FruCode 1.3.6.1.4.1.289.2.1.1.1.2.1.1.1 ed1032frucode read-only
Field Replaceable Unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follow: fru-none (0) , fru-bkplane (1), fru-ctp (2), fru-mpc (3), fru-cmm (4), fru-fan (5), fru-power (6), fru-panel (7), fru-gsm (8), fru-gls (9), fru-glx (10), fru-lsm (11), fru-gxx (12).
                                     ed1032FruPosition 1.3.6.1.4.1.289.2.1.1.1.2.1.1.2 ed1032fruposition read-only
This object identifies the position of the module. Port cards start from 1 to 8. All other cards start from 1 to 1 or 2.
                                     ed1032FruStatus 1.3.6.1.4.1.289.2.1.1.1.2.1.1.3 ed1032frustatus read-only
This object identifies the operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the back up module is used. update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed.
                                     ed1032FruPartNumber 1.3.6.1.4.1.289.2.1.1.1.2.1.1.4 displaystring read-only
This object identifies the part number of the module.
                                     ed1032FruSerialNumber 1.3.6.1.4.1.289.2.1.1.1.2.1.1.5 displaystring read-only
This object identifies the serial number of the module.
                                     ed1032FruPowerOnHours 1.3.6.1.4.1.289.2.1.1.1.2.1.1.6 counter read-only
This object indicates the number of the hours that the FRU has been in operation.
                                     ed1032FruTestDate 1.3.6.1.4.1.289.2.1.1.1.2.1.1.7 displaystring read-only
This object indicates final test date of the module.
                         ed1032Port 1.3.6.1.4.1.289.2.1.1.1.3
                             ed1032PortTable 1.3.6.1.4.1.289.2.1.1.1.3.1 no-access
A table that contains one entry for each switch port (stitch only).
                                 ed1032PortEntry 1.3.6.1.4.1.289.2.1.1.1.3.1.1 no-access
An entry containing the information of the switch port.
                                     ed1032PortIndex 1.3.6.1.4.1.289.2.1.1.1.3.1.1.1 ed1032portindex read-only
This object identifies the switch port.
                                     ed1032PortPhyState 1.3.6.1.4.1.289.2.1.1.1.3.1.1.2 ed1032portphystate read-only
This object identifies the physical state of the port.
                                     ed1032PortOpStatus 1.3.6.1.4.1.289.2.1.1.1.3.1.1.3 ed1032portstatus read-only
This object identifies the operational status of the port. The online state indicates that user frames can be passed.
                                     ed1032PortAdmStatus 1.3.6.1.4.1.289.2.1.1.1.3.1.1.4 ed1032portadmstatus read-write
The desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, ed1032PortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state.
                                     ed1032PortTxWords 1.3.6.1.4.1.289.2.1.1.1.3.1.1.11 counter read-only
This object counts the number of Fibre Channel words that the port has transmitted.
                                     ed1032PortRxWords 1.3.6.1.4.1.289.2.1.1.1.3.1.1.12 counter read-only
This object counts the number of Fibre Channel words that the port has received.
                                     ed1032PortTxFrames 1.3.6.1.4.1.289.2.1.1.1.3.1.1.13 counter read-only
This object counts the number of (Fibre Channel) frames that the port has transmitted.
                                     ed1032PortRxFrames 1.3.6.1.4.1.289.2.1.1.1.3.1.1.14 counter read-only
This object counts the number of (Fibre Channel) frames that the port has received.
                                     ed1032PortRxC2Frames 1.3.6.1.4.1.289.2.1.1.1.3.1.1.15 counter read-only
This object counts the number of Class 2 frames that the port has received.
                                     ed1032PortRxC3Frames 1.3.6.1.4.1.289.2.1.1.1.3.1.1.16 counter read-only
This object counts the number of Class 3 frames that the port has received.
                                     ed1032PortRxLCs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.17 counter read-only
This object counts the number of Link Control frames that the port has received.
                                     ed1032PortRxMcasts 1.3.6.1.4.1.289.2.1.1.1.3.1.1.18 counter read-only
This object counts the number of Multicast frames that the port has received.
                                     ed1032PortTooManyRdys 1.3.6.1.4.1.289.2.1.1.1.3.1.1.19 counter read-only
This object counts the number of times when RDYs exceeds the frames received.
                                     ed1032PortNoTxCredits 1.3.6.1.4.1.289.2.1.1.1.3.1.1.20 counter read-only
This object counts the amount of time that frame transmission is blocked by a transmit credit of zero. This is sampled once every 120 53.125 MHZ clocks, and the counter is incremented by 1 if the condition is true.
                                     ed1032PortRxEncFrs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.21 counter read-only
This object counts the number of encoding error or disparity error inside or outside frames received.
                                     ed1032PortRxCrcs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.22 counter read-only
This object counts the number of CRC errors detected for frames received.
                                     ed1032PortRxTruncs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.23 counter read-only
This object counts the number of truncated frames that the port has received.
                                     ed1032PortRxTooLongs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.24 counter read-only
This object counts the number of received frames that are too long.
                                     ed1032PortRxBadEofs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.25 counter read-only
This object counts the number of received frames that have bad EOF delimiter.
                                     ed1032PortRxBadOs 1.3.6.1.4.1.289.2.1.1.1.3.1.1.26 counter read-only
This object counts the number of invalid Ordered Sets received.
                                     ed1032PortC3Discards 1.3.6.1.4.1.289.2.1.1.1.3.1.1.27 counter read-only
This object counts the number of Class 3 frames that the port has discarded.
                                     ed1032PortMcastTimedOuts 1.3.6.1.4.1.289.2.1.1.1.3.1.1.28 counter read-only
This object counts the number of Multicast frames that has been timed out.
                                     ed1032PortTxMcasts 1.3.6.1.4.1.289.2.1.1.1.3.1.1.29 counter read-only
This object counts the number of Multicast frames that has been transmitted.
                                     ed1032PortTxThroughput 1.3.6.1.4.1.289.2.1.1.1.3.1.1.30 counter read-only
This object presents the Bps transmission rate.
                                     ed1032PortRxThroughput 1.3.6.1.4.1.289.2.1.1.1.3.1.1.31 counter read-only
This object presents the Bps reception rate.
           ed1032PortScn 1.3.6.1.4.1.2890.1
An ed1032PortScn(1) is generated whenever a Fc_Port changes its operational state. For instance, the Fc_Port goes from on-line to offline.
           ed1032FruScn 1.3.6.1.4.1.2890.2