Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 dell 1.3.6.1.4.1.674
         storage 1.3.6.1.4.1.674.10893
                     hardware 1.3.6.1.4.1.674.10893.2
                         mdStorageManager 1.3.6.1.4.1.674.10893.2.30
                               dellMDStorageArrayMIB 1.3.6.1.4.1.674.10893.2.30.0
MD Storage Array MIB
                               infoTable 1.3.6.1.4.1.674.10893.2.30.1 no-access
Information for array traps.
                                   infoEntry 1.3.6.1.4.1.674.10893.2.30.1.1 no-access
The data for array traps.
                                       deviceHostIPType 1.3.6.1.4.1.674.10893.2.30.1.1.1 inetaddresstype read-only
Type of IP Address of the network-attached device or device host. 0 unknown, 1 ipv4, 2 ipv6
                                       deviceHostIPAddr 1.3.6.1.4.1.674.10893.2.30.1.1.2 inetaddress read-only
IP Address of the network-attached device or device host.
                                       deviceHostName 1.3.6.1.4.1.674.10893.2.30.1.1.3 displaystring read-only
The user label for the host of the device being reported on.
                                       deviceUserLabel 1.3.6.1.4.1.674.10893.2.30.1.1.4 displaystring read-only
The user label for the device being reported on.
                                       deviceErrorCode 1.3.6.1.4.1.674.10893.2.30.1.1.5 displaystring read-only
The error code as reported by the device or host.
                                       eventTime 1.3.6.1.4.1.674.10893.2.30.1.1.6 displaystring read-only
The time at which the event happen on the device.
                                       trapDescription 1.3.6.1.4.1.674.10893.2.30.1.1.7 displaystring read-only
A string to indicate the nature of the trap
                                       componentType 1.3.6.1.4.1.674.10893.2.30.1.1.8 displaystring read-only
A string to identify the failing component type
                                       componentLocation 1.3.6.1.4.1.674.10893.2.30.1.1.9 displaystring read-only
A string to identify the location of the failing component
                                 storageArrayCritical 1.3.6.1.4.1.674.10893.2.300.1
This trap indicates an event where user-interaction is required immediately. Some example events are component failures or critical errors.
                                 storageArrayWarning 1.3.6.1.4.1.674.10893.2.300.2
This trap indicates an event where user-interaction may be required. Example are events that put the array in a non-optimal state.
                                 storageArrayInformational 1.3.6.1.4.1.674.10893.2.300.3
This trap indicates a non-failure event of interest where user interaction is generally not required.
                                 storageArrayDebug 1.3.6.1.4.1.674.10893.2.300.4
This trap indicates an interal system debug event of interest.