DLINKSW-DDM-MIB: View SNMP OID List / Download MIB

VENDOR: D-LINK


 Home MIB: DLINKSW-DDM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 dlinkSwDdmMIB 1.3.6.1.4.1.171.14.72
This MIB module defines objects for DDM.
       dDdmMIBNotifications 1.3.6.1.4.1.171.14.72.0
           dDdmAlarmTrap 1.3.6.1.4.1.171.14.72.0.1
The trap is sent when dDdmNotifyEnable is 'true' and an abnormal alarm situation occurs or recovers from an abnormal alarm situation to normal status.
           dDdmWarningTrap 1.3.6.1.4.1.171.14.72.0.2
The trap is sent when dDdmNotifyEnable is 'true' and an abnormal warning situation occurs or recovers from an abnormal warning situation to normal status.
       dDdmMIBObjects 1.3.6.1.4.1.171.14.72.1
           dDdmCtrl 1.3.6.1.4.1.171.14.72.1.1
               dDdmNotifyEnable 1.3.6.1.4.1.171.14.72.1.1.1 bits read-write
This object indicates whether a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then the specified notification can be generated. alarm(0) - sending an alarm level notification. warning(1) - sending an warning level notification. Bits: 'alarm': 0, 'warning': 1.
           dDdmIfCtrl 1.3.6.1.4.1.171.14.72.1.2
               dDdmIfCfgTable 1.3.6.1.4.1.171.14.72.1.2.1 no-access
This table contains a list of interface-specific DDM configuration.
                   dDdmIfCfgEntry 1.3.6.1.4.1.171.14.72.1.2.1.1 no-access
An entry manages DDM state and action on an interface.
                       dDdmIfCfgEnabled 1.3.6.1.4.1.171.14.72.1.2.1.1.1 truthvalue read-write
This object indicates the status of optical transceiver-monitoring function for a SFP port. When a SFP with transceiver-monitoring capability is plugged in a port but the transceiver-monitoring function of the port is disabled, system will not detect the SFP's abnormal status but user still can check the current status via dDdmIfInfoTable.
                       dDdmShutdownLevel 1.3.6.1.4.1.171.14.72.1.2.1.1.2 integer read-write
This object indicates the abnormal level which causes a port enter into errDisabled state. A value of 'none' indicates the shutdown action is disabled. Enumeration: 'none': 1, 'warning': 3, 'alarm': 2.
           dDdmThresholdMgmt 1.3.6.1.4.1.171.14.72.1.3
               dDdmThresholdCfgTable 1.3.6.1.4.1.171.14.72.1.3.1 no-access
This table contains a list of interface-specific threshold configuration for DDM.
                   dDdmThresholdCfgEntry 1.3.6.1.4.1.171.14.72.1.3.1.1 no-access
An entry in this table conists of one threshold configuration on an interface. An entry is created/removed when a configuration is added/deleted.
                       dDdmThresholdComponent 1.3.6.1.4.1.171.14.72.1.3.1.1.1 integer no-access
This object indicates the monitoring type. Note: Either txPowerMw(4) or txPowerDbm(5) can be configured on an interface. Either rxPowerMw(6) or rxPowerDbm(7) can be configured on an interface. In the above two cases, the existed entry will be deleted when the other new entry is created. Enumeration: 'txPowerDbm': 5, 'biasCurrent': 3, 'txPowerMw': 4, 'rxPowerDbm': 7, 'rxPowerMw': 6, 'voltage': 2, 'temperature': 1.
                       dDmThresholdAbnormalLevel 1.3.6.1.4.1.171.14.72.1.3.1.1.2 integer no-access
This object indicates the threshold type. Enumeration: 'lowWarning': 3, 'highAlarm': 1, 'highWarning': 2, 'lowAlarm': 4.
                       dDdmThresholdCfgValue 1.3.6.1.4.1.171.14.72.1.3.1.1.3 integer32 read-only
This object indicates the configured threshold. The value is interpreted within the context of dDdmThresholdComponent and dDmThresholdAbnormalLevel in the same row. The unit and valid range are as follows: Threshold Type Unit Valid Range ============= ===================== ================= Temperature milli-degrees Celsius -128,000 ~ 127,996 voltage centi-Volt 0 ~ 655 biasCurrent milli-amperes 0 ~ 131 txPowerMw tenths of a microwatt 0 ~ 65,535 txPowerDbm ten-thousandths of DBM -400,000 ~ 81,647 rxPowerMw tenths of a microwatt 0 ~ 65,535 rxPowerDbm ten-thousandths of DBM -400,000 ~ 81,647
                       dDdmThresholdCfgRowStatus 1.3.6.1.4.1.171.14.72.1.3.1.1.4 rowstatus read-only
The status of this conceptual row.
           dDdmInfo 1.3.6.1.4.1.171.14.72.1.4
               dDdmIfInfoTable 1.3.6.1.4.1.171.14.72.1.4.1 no-access
This table contains a list of information about current operating parameters of interfaces. Only the applicable interfaces (i.e.SFP module with DDM capability is plugged-in. ) will appear in this table. Note: 1. The threshold may be administratively configured or factory preset value defined by vendors. dDdmThresholdCfgTable provides the administrative threshold configuration. 2. It doesn't necessarily means the DDM is enabled on the interface when an entry appears in this table. dDdmIfCfgTable provides such information.
                   dDdmIfInfoEntry 1.3.6.1.4.1.171.14.72.1.4.1.1 no-access
An entry appears in this table contains current operating parameters for transceiver monitoring of a port.
                       dDdmIfInfoCurrentTemperature 1.3.6.1.4.1.171.14.72.1.4.1.1.1 integer32 read-only
This object indicates the current temperature in unit of 'milli-degrees Celsius' on the interface.
                       dDdmIfInfoTemperatureState 1.3.6.1.4.1.171.14.72.1.4.1.1.2 dlinkthresholdstate read-only
This object indicates the state of current temperature.
                       dDdmIfInfoHighAlarmTemperature 1.3.6.1.4.1.171.14.72.1.4.1.1.3 integer32 read-only
This object indicates the high alarm threshold, when the operating temperature rises above this value, it indicates an alarm status. The value is in unit of 'milli-degrees Celsius'.
                       dDdmIfInfoHighWarnTemperature 1.3.6.1.4.1.171.14.72.1.4.1.1.4 integer32 read-only
This object indicates the high warning threshold, when the operating temperature rises above this value, it indicates a warning status. The value is in unit of 'milli-degrees Celsius'.
                       dDdmIfInfoLowWarnTemperature 1.3.6.1.4.1.171.14.72.1.4.1.1.5 integer32 read-only
This object indicates the low warning threshold, when the operating temperature falls below this value, it indicates a warning status. The value is in unit of 'milli-degrees Celsius'.
                       dDdmIfInfoLowAlarmTemperature 1.3.6.1.4.1.171.14.72.1.4.1.1.6 integer32 read-only
This object indicates the low alarm threshold, when the operating temperature falls below this value, it indicates an alarm status. The value is in unit of 'milli-degrees Celsius'.
                       dDdmIfInfoCurrentVoltage 1.3.6.1.4.1.171.14.72.1.4.1.1.7 integer32 read-only
This object indicates the current voltage in unit of 'centi-Volt' on the interface.
                       dDdmIfInfoVoltageState 1.3.6.1.4.1.171.14.72.1.4.1.1.8 dlinkthresholdstate read-only
This object indicates the state of current voltage.
                       dDdmIfInfoHighAlarmVoltage 1.3.6.1.4.1.171.14.72.1.4.1.1.9 integer32 read-only
This object indicates the high alarm threshold, when the operating voltage rises above this value, it indicates an alarm status. The value is in unit of 'centi-Volt'.
                       dDdmIfInfoHighWarnVoltage 1.3.6.1.4.1.171.14.72.1.4.1.1.10 integer32 read-only
This object indicates the high warning threshold, when the operating voltage rises above this value, it indicates a warning status. The value is in unit of 'centi-Volt'.
                       dDdmIfInfoLowWarnVoltage 1.3.6.1.4.1.171.14.72.1.4.1.1.11 integer32 read-only
This object indicates the low warning threshold, when the operating voltage falls below this value, it indicates a warning status. The value is in unit of 'centi-Volt'.
                       dDdmIfInfoLowAlarmVoltage 1.3.6.1.4.1.171.14.72.1.4.1.1.12 integer32 read-only
This object indicates the low alarm threshold, when the operating voltage falls below this value, it indicates an alarm status. The value is in unit of 'centi-Volt'.
                       dDdmIfInfoCurrentBiasCurrent 1.3.6.1.4.1.171.14.72.1.4.1.1.13 integer32 read-only
This object indicates the current bias current in unit of 'milli-amperes' on the interface.
                       dDdmIfInfoBiasCurrentState 1.3.6.1.4.1.171.14.72.1.4.1.1.14 dlinkthresholdstate read-only
This object indicates the state of current BiasCurrent.
                       dDdmIfInfoHighAlarmBiasCurrent 1.3.6.1.4.1.171.14.72.1.4.1.1.15 integer32 read-only
This object indicates the high alarm threshold, when the operating bias current rises above this value, it indicates an alarm status. The value is in unit of 'milli-amperes'.
                       dDdmIfInfoHighWarnBiasCurrent 1.3.6.1.4.1.171.14.72.1.4.1.1.16 integer32 read-only
This object indicates the high warning threshold, when the operating bias current rises above this value, it indicates a warning status. The value is in unit of 'milli-amperes'.
                       dDdmIfInfoLowWarnBiasCurrent 1.3.6.1.4.1.171.14.72.1.4.1.1.17 integer32 read-only
This object indicates the low warning threshold, when the operating bias current falls below this value, it indicates a warning status. The value is in unit of 'milli-amperes'.
                       dDdmIfInfoLowAlarmBiasCurrent 1.3.6.1.4.1.171.14.72.1.4.1.1.18 integer32 read-only
This object indicates the low alarm threshold, when the operating bias current falls below this value, it indicates an alarm status. The value is in unit of 'milli-amperes'.
                       dDdmIfInfoCurrentTxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.19 integer32 read-only
This object indicates the current output power in unit of 'tenths of a microwatt' on the interface.
                       dDdmIfInfoTxPowerState 1.3.6.1.4.1.171.14.72.1.4.1.1.20 dlinkthresholdstate read-only
This object indicates the state of current output power.
                       dDdmIfInfoHighAlarmTxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.21 integer32 read-only
This object indicates the high alarm threshold, when the operating output power rises above this value, it indicates an alarm status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoHighWarnTxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.22 integer32 read-only
This object indicates the high warning threshold, when the operating output power rises above this value, it indicates a warning status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoLowWarnTxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.23 integer32 read-only
This object indicates the low warning threshold, when the operating output power falls below this value, it indicates a warning status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoLowAlarmTxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.24 integer32 read-only
This object indicates the low alarm threshold, when the operating output power falls below this value, it indicates an alarm status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoCurrentRxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.25 integer32 read-only
This object indicates the current input power in unit of 'tenths of a microwatt' on the interface.
                       dDdmIfInfoRxPowerState 1.3.6.1.4.1.171.14.72.1.4.1.1.26 dlinkthresholdstate read-only
This object indicates the state of current input power.
                       dDdmIfInfoHighAlarmRxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.27 integer32 read-only
This object indicates the high alarm threshold, when the operating input power rises above this value, it indicates an alarm status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoHighWarnRxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.28 integer32 read-only
This object indicates the high warning threshold, when the operating input power rises above this value, it indicates a warning status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoLowWarnRxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.29 integer32 read-only
This object indicates the low warning threshold, when the operating input power falls below this value, it indicates a warning status. The value is in unit of 'tenths of a microwatt'.
                       dDdmIfInfoLowAlarmRxPower 1.3.6.1.4.1.171.14.72.1.4.1.1.30 integer32 read-only
This object indicates the low alarm threshold, when the operating input power falls below this value, it indicates an alarm status. The value is in unit of 'tenths of a microwatt'.
           dDdmNotifyInfo 1.3.6.1.4.1.171.14.72.1.5
               dDdmNotifyInfoIfIndex 1.3.6.1.4.1.171.14.72.1.5.1 interfaceindex no-access
This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the ifIndex on which the monitoring value rises above or falls below the corresponding threshold.
               dDdmNotifyInfoComponent 1.3.6.1.4.1.171.14.72.1.5.2 integer no-access
This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the abnormal component. Enumeration: 'voltage': 2, 'rxPowerMw': 5, 'biasCurrent': 3, 'txPowerMw': 4, 'temperature': 1.
               dDdmNotifyInfoAbnormalLevel 1.3.6.1.4.1.171.14.72.1.5.3 integer no-access
This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the abnormal level. Enumeration: 'high': 1, 'low': 2.
               dDdmNotifyInfoThresholdExceedOrRecover 1.3.6.1.4.1.171.14.72.1.5.4 integer no-access
This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the GBIC is exceeding its threshold or recover to normal status. Enumeration: 'exceed': 1, 'recover': 2.
       dDdmMIBConformance 1.3.6.1.4.1.171.14.72.2
           dDdmCompliances 1.3.6.1.4.1.171.14.72.2.1
               dDdmCompliance 1.3.6.1.4.1.171.14.72.2.1.1
The compliance statement for entities which implement the DLINKSW-DDM-MIB.
           dDdmGroups 1.3.6.1.4.1.171.14.72.2.2
               dDdmInfoGroup 1.3.6.1.4.1.171.14.72.2.2.1
A collection of objects provides DDM operating information.
               dDdmCfgGroup 1.3.6.1.4.1.171.14.72.2.2.2
A collection of objects provides DDM configuration.
               dDdmNotifyGroup 1.3.6.1.4.1.171.14.72.2.2.3
The collection of notifications used for DDM.