DLINK-EQUIPMENT-MIB: View SNMP OID List / Download MIB

VENDOR: D-LINK


 Home MIB: DLINK-EQUIPMENT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 swDlinkEquipmentMIB 1.3.6.1.4.1.171.12.11
DLink equipments MIB .
       swDlinkEquipmentMib 1.3.6.1.4.1.171.12.11.1
           swDlinkEquipmentCapacity 1.3.6.1.4.1.171.12.11.1.1 bits read-only
Indicates the equipment capacity supported in the system . Bits: 'stackingCapable': 3, 'tempteratureDetection': 2, 'redundantPowerCapable': 1, 'chassisCapable': 4, 'fanCapable': 0.
           swPowerTable 1.3.6.1.4.1.171.12.11.1.6 no-access
A list of temperature.
               swPowerEntry 1.3.6.1.4.1.171.12.11.1.6.1 no-access
A entry of Power information.
                   swPowerUnitIndex 1.3.6.1.4.1.171.12.11.1.6.1.1 integer read-only
Indicates ID of the unit in the System
                   swPowerID 1.3.6.1.4.1.171.12.11.1.6.1.2 integer read-only
Indicates ID of the power 1 : main power 2 : redundant power .
                   swPowerStatus 1.3.6.1.4.1.171.12.11.1.6.1.3 integer read-only
Indicates status of the power Enumeration: 'disconnect': 6, 'working': 3, 'overCurrent': 2, 'other': 0, 'connect': 5, 'fail': 4, 'lowVoltage': 1.
           swUnitMgmt 1.3.6.1.4.1.171.12.11.1.9
               swUnitStackingVersion 1.3.6.1.4.1.171.12.11.1.9.1 integer read-only
This object indicates the version of this stacking system .
               swUnitMaxSupportedUnits 1.3.6.1.4.1.171.12.11.1.9.2 integer read-only
Maximum number of units are supported in the system.
               swUnitNumOfUnit 1.3.6.1.4.1.171.12.11.1.9.3 integer read-only
The current number of units.
               swUnitMgmtTable 1.3.6.1.4.1.171.12.11.1.9.4 no-access
This table contains the unit information.
                   swUnitMgmtEntry 1.3.6.1.4.1.171.12.11.1.9.4.1 no-access
A list of management information for each unit in the system.
                       swUnitMgmtId 1.3.6.1.4.1.171.12.11.1.9.4.1.1 integer read-only
This object indicates the specific entry in the stacking/chassis table.
                       swUnitMgmtMacAddr 1.3.6.1.4.1.171.12.11.1.9.4.1.2 macaddress read-only
The Mac address of this unit.
                       swUnitMgmtStartPort 1.3.6.1.4.1.171.12.11.1.9.4.1.3 integer read-only
This object indicates the start port of this unit.
                       swUnitMgmtPortRange 1.3.6.1.4.1.171.12.11.1.9.4.1.4 integer read-only
This object indicates the total ports of this unit.
                       swUnitMgmtFrontPanelLedStatus 1.3.6.1.4.1.171.12.11.1.9.4.1.5 octet string read-only
This object is a set of system LED indications. The first three octets is defined as system LED. The first LED is power LED. The second LED is console LED. The third LED is RPS (Redundancy Power Supply) LED. The other octets following the second octets are the logical port LED (following dot1dBasePort ordering). One byte is presented to one port and this byte is presentd to the Link/Activity LED. Link/Activity LED : The most significant bit is used for blink/solid: 8 = The LED blinks. The second significant bit is used for link status: 1 = link fail. 2 = link pass. The four remaining bits are currently unused and must be 0.
                       swUnitMgmtCtrlMode 1.3.6.1.4.1.171.12.11.1.9.4.1.6 integer read-write
This object indicates the stack mode that user configed for this unit. The object only can be configed when the device is stand alone. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. auto(2) - the system will auto assign this stack role of this unit to be stand-alone(3), master(4), or slave(5). stand-alone(3) - the unit is forced to stand alone. master(4) - the unit is forced to master. If this unit is seleted to be master, it can modify the configuration of the stacking system. slave(5) - the unit is forced to slave. If this unit is seleted to be slave, it only can view the configuration of the stacking system. Enumeration: 'auto': 2, 'other': 1, 'master': 4, 'stand-alone': 3, 'slave': 5.
                       swUnitMgmtCurrentMode 1.3.6.1.4.1.171.12.11.1.9.4.1.7 integer read-only
The current stack role of this unit. Enumeration: 'auto': 2, 'other': 1, 'master': 4, 'stand-alone': 3, 'slave': 5.
                       swUnitMgmtVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.8 displaystring read-only
This object indicates the version of this stacking unit.
                       swUnitMgmtModuleName 1.3.6.1.4.1.171.12.11.1.9.4.1.9 displaystring read-only
A textual string containing module name of the stacking unit.
       swDlinkEquipmentNotify 1.3.6.1.4.1.171.12.11.2
           swEquipmentNotification 1.3.6.1.4.1.171.12.11.2.2
               swEquipPowerNotification 1.3.6.1.4.1.171.12.11.2.2.2
                   swEquipPowerNotifyPerfix 1.3.6.1.4.1.171.12.11.2.2.2.0
                       swPowerFailure 1.3.6.1.4.1.171.12.11.2.2.2.0.2
Power Failure notification.
                       swPowerRecover 1.3.6.1.4.1.171.12.11.2.2.2.0.3
Power Recover notification.
           swNotificationBindings 1.3.6.1.4.1.171.12.11.2.3