DGPPDU-MIB: View SNMP OID List / Download MIB
VENDOR: DIGIPOWER MANUFACTURING INC.
Home | MIB: DGPPDU-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
dgp | 1.3.6.1.4.1.17420 | |||
products | 1.3.6.1.4.1.17420.1 | |||
devTable | 1.3.6.1.4.1.17420.1.2 | |||
devID | 1.3.6.1.4.1.17420.1.2.1 | integer | read-only |
The ID number of dev. |
devIP | 1.3.6.1.4.1.17420.1.2.2 | displaystring | read-write |
Indicate current IP address, netmask, default gateway, and DNS server. |
devMAC | 1.3.6.1.4.1.17420.1.2.3 | displaystring | read-only |
Indicate current MAC address. |
devVersion | 1.3.6.1.4.1.17420.1.2.4 | displaystring | read-only |
Indicate current firmware version. |
devInfo | 1.3.6.1.4.1.17420.1.2.5 | displaystring | read-only |
Indicate the count of attached PDUs and their id. |
devValues | 1.3.6.1.4.1.17420.1.2.6 | displaystring | read-only |
Indicate the PDU values (currents) from PDU1 to PDU16 |
devTemperature | 1.3.6.1.4.1.17420.1.2.7 | integer | read-only |
Indicate the PDU temperature in Celsius degree |
devHumidity | 1.3.6.1.4.1.17420.1.2.8 | integer | read-only |
Indicate the PDU humidity in percentage (%) |
pduTable | 1.3.6.1.4.1.17420.1.2.9 | |||
pdu01Entry | 1.3.6.1.4.1.17420.1.2.9.1 | |||
pdu01Value | 1.3.6.1.4.1.17420.1.2.9.1.11 | integer | read-only |
Indicate the current of PDU-01 detect. |
pdu01SubValues | 1.3.6.1.4.1.17420.1.2.9.1.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu01OutletStatus | 1.3.6.1.4.1.17420.1.2.9.1.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu01OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.1.14 | |||
pdu01Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.1.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu01Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.1.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu01Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.1.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu01Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.1.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu01Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.1.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu01Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.1.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu01Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.1.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu01Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.1.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet9Config | 1.3.6.1.4.1.17420.1.2.9.1.14.9 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet10Config | 1.3.6.1.4.1.17420.1.2.9.1.14.10 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet11Config | 1.3.6.1.4.1.17420.1.2.9.1.14.11 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu01Outlet12Config | 1.3.6.1.4.1.17420.1.2.9.1.14.12 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu01Outlet13Config | 1.3.6.1.4.1.17420.1.2.9.1.14.13 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu01Outlet14Config | 1.3.6.1.4.1.17420.1.2.9.1.14.14 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu01Outlet15Config | 1.3.6.1.4.1.17420.1.2.9.1.14.15 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu01Outlet16Config | 1.3.6.1.4.1.17420.1.2.9.1.14.16 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu01Outlet17Config | 1.3.6.1.4.1.17420.1.2.9.1.14.17 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu01Outlet18Config | 1.3.6.1.4.1.17420.1.2.9.1.14.18 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet19Config | 1.3.6.1.4.1.17420.1.2.9.1.14.19 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet20Config | 1.3.6.1.4.1.17420.1.2.9.1.14.20 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu01Outlet21Config | 1.3.6.1.4.1.17420.1.2.9.1.14.21 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu01Outlet22Config | 1.3.6.1.4.1.17420.1.2.9.1.14.22 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu01Outlet23Config | 1.3.6.1.4.1.17420.1.2.9.1.14.23 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu01Outlet24Config | 1.3.6.1.4.1.17420.1.2.9.1.14.24 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu01Threshold1 | 1.3.6.1.4.1.17420.1.2.9.1.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu01Threshold2 | 1.3.6.1.4.1.17420.1.2.9.1.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu01Voltage | 1.3.6.1.4.1.17420.1.2.9.1.17 | integer | read-only |
Indicate voltage of PDU. |
pdu01ModelName | 1.3.6.1.4.1.17420.1.2.9.1.18 | displaystring | read-only |
Indicate PDU model name. |
pdu01ModelNo | 1.3.6.1.4.1.17420.1.2.9.1.19 | displaystring | read-only |
Indicate PDU model number. |
pdu01Identify | 1.3.6.1.4.1.17420.1.2.9.1.20 | displaystring | read-only |
Indicate PDU identify. |
pdu02Entry | 1.3.6.1.4.1.17420.1.2.9.2 | |||
pdu02Value | 1.3.6.1.4.1.17420.1.2.9.2.11 | integer | read-only |
Indicate the current of PDU-02 detect. |
pdu02SubValues | 1.3.6.1.4.1.17420.1.2.9.2.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu02OutletStatus | 1.3.6.1.4.1.17420.1.2.9.2.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu02OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.2.14 | |||
pdu02Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.2.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu02Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.2.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu02Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.2.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu02Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.2.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu02Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.2.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu02Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.2.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu02Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.2.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu02Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.2.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu02Threshold1 | 1.3.6.1.4.1.17420.1.2.9.2.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu02Threshold2 | 1.3.6.1.4.1.17420.1.2.9.2.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu02Voltage | 1.3.6.1.4.1.17420.1.2.9.2.17 | integer | read-only |
Indicate voltage of PDU. |
pdu02ModelName | 1.3.6.1.4.1.17420.1.2.9.2.18 | displaystring | read-only |
Indicate PDU model name. |
pdu02ModelNo | 1.3.6.1.4.1.17420.1.2.9.2.19 | displaystring | read-only |
Indicate PDU model number. |
pdu02Identify | 1.3.6.1.4.1.17420.1.2.9.2.20 | displaystring | read-only |
Indicate PDU identify. |
pdu03Entry | 1.3.6.1.4.1.17420.1.2.9.3 | |||
pdu03Value | 1.3.6.1.4.1.17420.1.2.9.3.11 | integer | read-only |
Indicate the current of PDU-03 detect. |
pdu03SubValues | 1.3.6.1.4.1.17420.1.2.9.3.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu03OutletStatus | 1.3.6.1.4.1.17420.1.2.9.3.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu03OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.3.14 | |||
pdu03Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.3.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu03Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.3.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu03Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.3.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu03Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.3.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu03Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.3.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu03Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.3.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu03Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.3.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu03Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.3.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu03Threshold1 | 1.3.6.1.4.1.17420.1.2.9.3.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu03Threshold2 | 1.3.6.1.4.1.17420.1.2.9.3.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu03Voltage | 1.3.6.1.4.1.17420.1.2.9.3.17 | integer | read-only |
Indicate voltage of PDU. |
pdu03ModelName | 1.3.6.1.4.1.17420.1.2.9.3.18 | displaystring | read-only |
Indicate PDU model name. |
pdu03ModelNo | 1.3.6.1.4.1.17420.1.2.9.3.19 | displaystring | read-only |
Indicate PDU model number. |
pdu03Identify | 1.3.6.1.4.1.17420.1.2.9.3.20 | displaystring | read-only |
Indicate PDU identify. |
pdu04Entry | 1.3.6.1.4.1.17420.1.2.9.4 | |||
pdu04Value | 1.3.6.1.4.1.17420.1.2.9.4.11 | integer | read-only |
Indicate the current of PDU-04 detect. |
pdu04SubValues | 1.3.6.1.4.1.17420.1.2.9.4.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu04OutletStatus | 1.3.6.1.4.1.17420.1.2.9.4.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu04OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.4.14 | |||
pdu04Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.4.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu04Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.4.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu04Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.4.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu04Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.4.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu04Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.4.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu04Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.4.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu04Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.4.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu04Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.4.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu04Threshold1 | 1.3.6.1.4.1.17420.1.2.9.4.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu04Threshold2 | 1.3.6.1.4.1.17420.1.2.9.4.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu04Voltage | 1.3.6.1.4.1.17420.1.2.9.4.17 | integer | read-only |
Indicate voltage of PDU. |
pdu04ModelName | 1.3.6.1.4.1.17420.1.2.9.4.18 | displaystring | read-only |
Indicate PDU model name. |
pdu04ModelNo | 1.3.6.1.4.1.17420.1.2.9.4.19 | displaystring | read-only |
Indicate PDU model number. |
pdu04Identify | 1.3.6.1.4.1.17420.1.2.9.4.20 | displaystring | read-only |
Indicate PDU identify. |
pdu05Entry | 1.3.6.1.4.1.17420.1.2.9.5 | |||
pdu05Value | 1.3.6.1.4.1.17420.1.2.9.5.11 | integer | read-only |
Indicate the current of PDU-05 detect. |
pdu05SubValues | 1.3.6.1.4.1.17420.1.2.9.5.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu05OutletStatus | 1.3.6.1.4.1.17420.1.2.9.5.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu05OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.5.14 | |||
pdu05Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.5.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu05Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.5.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu05Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.5.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu05Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.5.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu05Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.5.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu05Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.5.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu05Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.5.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu05Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.5.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu05Threshold1 | 1.3.6.1.4.1.17420.1.2.9.5.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu05Threshold2 | 1.3.6.1.4.1.17420.1.2.9.5.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu05Voltage | 1.3.6.1.4.1.17420.1.2.9.5.17 | integer | read-only |
Indicate voltage of PDU. |
pdu05ModelName | 1.3.6.1.4.1.17420.1.2.9.5.18 | displaystring | read-only |
Indicate PDU model name. |
pdu05ModelNo | 1.3.6.1.4.1.17420.1.2.9.5.19 | displaystring | read-only |
Indicate PDU model number. |
pdu05Identify | 1.3.6.1.4.1.17420.1.2.9.5.20 | displaystring | read-only |
Indicate PDU identify. |
pdu06Entry | 1.3.6.1.4.1.17420.1.2.9.6 | |||
pdu06Value | 1.3.6.1.4.1.17420.1.2.9.6.11 | integer | read-only |
Indicate the current of PDU-06 detect. |
pdu06SubValues | 1.3.6.1.4.1.17420.1.2.9.6.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu06OutletStatus | 1.3.6.1.4.1.17420.1.2.9.6.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu06OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.6.14 | |||
pdu06Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.6.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu06Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.6.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu06Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.6.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu06Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.6.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu06Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.6.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu06Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.6.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu06Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.6.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu06Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.6.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu06Threshold1 | 1.3.6.1.4.1.17420.1.2.9.6.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu06Threshold2 | 1.3.6.1.4.1.17420.1.2.9.6.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu06Voltage | 1.3.6.1.4.1.17420.1.2.9.6.17 | integer | read-only |
Indicate voltage of PDU. |
pdu06ModelName | 1.3.6.1.4.1.17420.1.2.9.6.18 | displaystring | read-only |
Indicate PDU model name. |
pdu06ModelNo | 1.3.6.1.4.1.17420.1.2.9.6.19 | displaystring | read-only |
Indicate PDU model number. |
pdu06Identify | 1.3.6.1.4.1.17420.1.2.9.6.20 | displaystring | read-only |
Indicate PDU identify. |
pdu07Entry | 1.3.6.1.4.1.17420.1.2.9.7 | |||
pdu07Value | 1.3.6.1.4.1.17420.1.2.9.7.11 | integer | read-only |
Indicate the current of PDU-07 detect. |
pdu07SubValues | 1.3.6.1.4.1.17420.1.2.9.7.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu07OutletStatus | 1.3.6.1.4.1.17420.1.2.9.7.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu07OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.7.14 | |||
pdu07Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.7.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu07Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.7.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu07Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.7.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu07Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.7.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu07Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.7.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu07Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.7.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu07Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.7.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu07Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.7.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu07Threshold1 | 1.3.6.1.4.1.17420.1.2.9.7.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu07Threshold2 | 1.3.6.1.4.1.17420.1.2.9.7.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu07Voltage | 1.3.6.1.4.1.17420.1.2.9.7.17 | integer | read-only |
Indicate voltage of PDU. |
pdu07ModelName | 1.3.6.1.4.1.17420.1.2.9.7.18 | displaystring | read-only |
Indicate PDU model name. |
pdu07ModelNo | 1.3.6.1.4.1.17420.1.2.9.7.19 | displaystring | read-only |
Indicate PDU model number. |
pdu07Identify | 1.3.6.1.4.1.17420.1.2.9.7.20 | displaystring | read-only |
Indicate PDU identify. |
pdu08Entry | 1.3.6.1.4.1.17420.1.2.9.8 | |||
pdu08Value | 1.3.6.1.4.1.17420.1.2.9.8.11 | integer | read-only |
Indicate the current of PDU-08 detect. |
pdu08SubValues | 1.3.6.1.4.1.17420.1.2.9.8.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu08OutletStatus | 1.3.6.1.4.1.17420.1.2.9.8.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu08OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.8.14 | |||
pdu08Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.8.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu08Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.8.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu08Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.8.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu08Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.8.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu08Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.8.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu08Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.8.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu08Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.8.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu08Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.8.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu08Threshold1 | 1.3.6.1.4.1.17420.1.2.9.8.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu08Threshold2 | 1.3.6.1.4.1.17420.1.2.9.8.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu08Voltage | 1.3.6.1.4.1.17420.1.2.9.8.17 | integer | read-only |
Indicate voltage of PDU. |
pdu08ModelName | 1.3.6.1.4.1.17420.1.2.9.8.18 | displaystring | read-only |
Indicate PDU model name. |
pdu08ModelNo | 1.3.6.1.4.1.17420.1.2.9.8.19 | displaystring | read-only |
Indicate PDU model number. |
pdu08Identify | 1.3.6.1.4.1.17420.1.2.9.8.20 | displaystring | read-only |
Indicate PDU identify. |
pdu09Entry | 1.3.6.1.4.1.17420.1.2.9.9 | |||
pdu09Value | 1.3.6.1.4.1.17420.1.2.9.9.11 | integer | read-only |
Indicate the current of PDU-09 detect. |
pdu09SubValues | 1.3.6.1.4.1.17420.1.2.9.9.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu09OutletStatus | 1.3.6.1.4.1.17420.1.2.9.9.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu09OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.9.14 | |||
pdu09Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.9.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu09Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.9.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu09Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.9.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu09Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.9.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu09Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.9.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu09Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.9.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu09Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.9.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu09Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.9.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu09Threshold1 | 1.3.6.1.4.1.17420.1.2.9.9.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu09Threshold2 | 1.3.6.1.4.1.17420.1.2.9.9.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu09Voltage | 1.3.6.1.4.1.17420.1.2.9.9.17 | integer | read-only |
Indicate voltage of PDU. |
pdu09ModelName | 1.3.6.1.4.1.17420.1.2.9.9.18 | displaystring | read-only |
Indicate PDU model name. |
pdu09ModelNo | 1.3.6.1.4.1.17420.1.2.9.9.19 | displaystring | read-only |
Indicate PDU model number. |
pdu09Identify | 1.3.6.1.4.1.17420.1.2.9.9.20 | displaystring | read-only |
Indicate PDU identify. |
pdu10Entry | 1.3.6.1.4.1.17420.1.2.9.10 | |||
pdu10Value | 1.3.6.1.4.1.17420.1.2.9.10.11 | integer | read-only |
Indicate the current of PDU-10 detect. |
pdu10SubValues | 1.3.6.1.4.1.17420.1.2.9.10.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu10OutletStatus | 1.3.6.1.4.1.17420.1.2.9.10.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu10OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.10.14 | |||
pdu10Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.10.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu10Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.10.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu10Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.10.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu10Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.10.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu10Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.10.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu10Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.10.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu10Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.10.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu10Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.10.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu10Threshold1 | 1.3.6.1.4.1.17420.1.2.9.10.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu10Threshold2 | 1.3.6.1.4.1.17420.1.2.9.10.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu10Voltage | 1.3.6.1.4.1.17420.1.2.9.10.17 | integer | read-only |
Indicate voltage of PDU. |
pdu10ModelName | 1.3.6.1.4.1.17420.1.2.9.10.18 | displaystring | read-only |
Indicate PDU model name. |
pdu10ModelNo | 1.3.6.1.4.1.17420.1.2.9.10.19 | displaystring | read-only |
Indicate PDU model number. |
pdu10Identify | 1.3.6.1.4.1.17420.1.2.9.10.20 | displaystring | read-only |
Indicate PDU identify. |
pdu11Entry | 1.3.6.1.4.1.17420.1.2.9.11 | |||
pdu11Value | 1.3.6.1.4.1.17420.1.2.9.11.11 | integer | read-only |
Indicate the current of PDU-11 detect. |
pdu11SubValues | 1.3.6.1.4.1.17420.1.2.9.11.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu11OutletStatus | 1.3.6.1.4.1.17420.1.2.9.11.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu11OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.11.14 | |||
pdu11Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.11.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu11Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.11.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu11Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.11.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu11Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.11.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu11Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.11.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu11Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.11.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu11Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.11.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu11Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.11.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu11Threshold1 | 1.3.6.1.4.1.17420.1.2.9.11.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu11Threshold2 | 1.3.6.1.4.1.17420.1.2.9.11.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu11Voltage | 1.3.6.1.4.1.17420.1.2.9.11.17 | integer | read-only |
Indicate voltage of PDU. |
pdu11ModelName | 1.3.6.1.4.1.17420.1.2.9.11.18 | displaystring | read-only |
Indicate PDU model name. |
pdu11ModelNo | 1.3.6.1.4.1.17420.1.2.9.11.19 | displaystring | read-only |
Indicate PDU model number. |
pdu11Identify | 1.3.6.1.4.1.17420.1.2.9.11.20 | displaystring | read-only |
Indicate PDU identify. |
pdu12Entry | 1.3.6.1.4.1.17420.1.2.9.12 | |||
pdu12Value | 1.3.6.1.4.1.17420.1.2.9.12.11 | integer | read-only |
Indicate the current of PDU-12 detect. |
pdu12SubValues | 1.3.6.1.4.1.17420.1.2.9.12.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu12OutletStatus | 1.3.6.1.4.1.17420.1.2.9.12.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu12OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.12.14 | |||
pdu12Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.12.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu12Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.12.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu12Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.12.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu12Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.12.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu12Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.12.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu12Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.12.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu12Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.12.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu12Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.12.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu12Threshold1 | 1.3.6.1.4.1.17420.1.2.9.12.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu12Threshold2 | 1.3.6.1.4.1.17420.1.2.9.12.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu12Voltage | 1.3.6.1.4.1.17420.1.2.9.12.17 | integer | read-only |
Indicate voltage of PDU. |
pdu12ModelName | 1.3.6.1.4.1.17420.1.2.9.12.18 | displaystring | read-only |
Indicate PDU model name. |
pdu12ModelNo | 1.3.6.1.4.1.17420.1.2.9.12.19 | displaystring | read-only |
Indicate PDU model number. |
pdu12Identify | 1.3.6.1.4.1.17420.1.2.9.12.20 | displaystring | read-only |
Indicate PDU identify. |
pdu13Entry | 1.3.6.1.4.1.17420.1.2.9.13 | |||
pdu13Value | 1.3.6.1.4.1.17420.1.2.9.13.11 | integer | read-only |
Indicate the current of PDU-13 detect. |
pdu13SubValues | 1.3.6.1.4.1.17420.1.2.9.13.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu13OutletStatus | 1.3.6.1.4.1.17420.1.2.9.13.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu13OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.13.14 | |||
pdu13Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.13.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu13Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.13.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu13Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.13.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu13Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.13.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu13Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.13.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu13Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.13.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu13Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.13.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu13Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.13.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu13Threshold1 | 1.3.6.1.4.1.17420.1.2.9.13.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu13Threshold2 | 1.3.6.1.4.1.17420.1.2.9.13.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu13Voltage | 1.3.6.1.4.1.17420.1.2.9.13.17 | integer | read-only |
Indicate voltage of PDU. |
pdu13ModelName | 1.3.6.1.4.1.17420.1.2.9.13.18 | displaystring | read-only |
Indicate PDU model name. |
pdu13ModelNo | 1.3.6.1.4.1.17420.1.2.9.13.19 | displaystring | read-only |
Indicate PDU model number. |
pdu13Identify | 1.3.6.1.4.1.17420.1.2.9.13.20 | displaystring | read-only |
Indicate PDU identify. |
pdu14Entry | 1.3.6.1.4.1.17420.1.2.9.14 | |||
pdu14Value | 1.3.6.1.4.1.17420.1.2.9.14.11 | integer | read-only |
Indicate the current of PDU-14 detect. |
pdu14SubValues | 1.3.6.1.4.1.17420.1.2.9.14.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu14OutletStatus | 1.3.6.1.4.1.17420.1.2.9.14.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu14OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.14.14 | |||
pdu14Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.14.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu14Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.14.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu14Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.14.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu14Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.14.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu14Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.14.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu14Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.14.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu14Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.14.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu14Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.14.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu14Threshold1 | 1.3.6.1.4.1.17420.1.2.9.14.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu14Threshold2 | 1.3.6.1.4.1.17420.1.2.9.14.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu14Voltage | 1.3.6.1.4.1.17420.1.2.9.14.17 | integer | read-only |
Indicate voltage of PDU. |
pdu14ModelName | 1.3.6.1.4.1.17420.1.2.9.14.18 | displaystring | read-only |
Indicate PDU model name. |
pdu14ModelNo | 1.3.6.1.4.1.17420.1.2.9.14.19 | displaystring | read-only |
Indicate PDU model number. |
pdu14Identify | 1.3.6.1.4.1.17420.1.2.9.14.20 | displaystring | read-only |
Indicate PDU identify. |
pdu15Entry | 1.3.6.1.4.1.17420.1.2.9.15 | |||
pdu15Value | 1.3.6.1.4.1.17420.1.2.9.15.11 | integer | read-only |
Indicate the current of PDU-15 detect. |
pdu15SubValues | 1.3.6.1.4.1.17420.1.2.9.15.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu15OutletStatus | 1.3.6.1.4.1.17420.1.2.9.15.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu15OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.15.14 | |||
pdu15Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.15.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu15Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.15.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu15Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.15.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu15Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.15.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu15Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.15.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu15Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.15.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu15Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.15.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu15Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.15.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu15Threshold1 | 1.3.6.1.4.1.17420.1.2.9.15.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu15Threshold2 | 1.3.6.1.4.1.17420.1.2.9.15.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu15Voltage | 1.3.6.1.4.1.17420.1.2.9.15.17 | integer | read-only |
Indicate voltage of PDU. |
pdu15ModelName | 1.3.6.1.4.1.17420.1.2.9.15.18 | displaystring | read-only |
Indicate PDU model name. |
pdu15ModelNo | 1.3.6.1.4.1.17420.1.2.9.15.19 | displaystring | read-only |
Indicate PDU model number. |
pdu15Identify | 1.3.6.1.4.1.17420.1.2.9.15.20 | displaystring | read-only |
Indicate PDU identify. |
pdu16Entry | 1.3.6.1.4.1.17420.1.2.9.16 | |||
pdu16Value | 1.3.6.1.4.1.17420.1.2.9.16.11 | integer | read-only |
Indicate the current of PDU-16 detect. |
pdu16SubValues | 1.3.6.1.4.1.17420.1.2.9.16.12 | displaystring | read-only |
Indicate the outlet values (currents) from Outlet1 to Outlet8 |
pdu16OutletStatus | 1.3.6.1.4.1.17420.1.2.9.16.13 | displaystring | read-only |
Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 |
pdu16OutletConfigs | 1.3.6.1.4.1.17420.1.2.9.16.14 | |||
pdu16Outlet1Config | 1.3.6.1.4.1.17420.1.2.9.16.14.1 | displaystring | read-only |
Indicate the configuration of Outlet1 |
pdu16Outlet2Config | 1.3.6.1.4.1.17420.1.2.9.16.14.2 | displaystring | read-only |
Indicate the configuration of Outlet2 |
pdu16Outlet3Config | 1.3.6.1.4.1.17420.1.2.9.16.14.3 | displaystring | read-only |
Indicate the configuration of Outlet3 |
pdu16Outlet4Config | 1.3.6.1.4.1.17420.1.2.9.16.14.4 | displaystring | read-only |
Indicate the configuration of Outlet4 |
pdu16Outlet5Config | 1.3.6.1.4.1.17420.1.2.9.16.14.5 | displaystring | read-only |
Indicate the configuration of Outlet5 |
pdu16Outlet6Config | 1.3.6.1.4.1.17420.1.2.9.16.14.6 | displaystring | read-only |
Indicate the configuration of Outlet6 |
pdu16Outlet7Config | 1.3.6.1.4.1.17420.1.2.9.16.14.7 | displaystring | read-only |
Indicate the configuration of Outlet7 |
pdu16Outlet8Config | 1.3.6.1.4.1.17420.1.2.9.16.14.8 | displaystring | read-only |
Indicate the configuration of Outlet8 |
pdu16Threshold1 | 1.3.6.1.4.1.17420.1.2.9.16.15 | integer | read-write |
Indicate current threshold 1 (warning current). |
pdu16Threshold2 | 1.3.6.1.4.1.17420.1.2.9.16.16 | integer | read-write |
Indicate current threshold 2 (critical current). |
pdu16Voltage | 1.3.6.1.4.1.17420.1.2.9.16.17 | integer | read-only |
Indicate voltage of PDU. |
pdu16ModelName | 1.3.6.1.4.1.17420.1.2.9.16.18 | displaystring | read-only |
Indicate PDU model name. |
pdu16ModelNo | 1.3.6.1.4.1.17420.1.2.9.16.19 | displaystring | read-only |
Indicate PDU model number. |
pdu16Identify | 1.3.6.1.4.1.17420.1.2.9.16.20 | displaystring | read-only |
Indicate PDU identify. |
devOutOfThreshold1 | 1.3.6.1.4.1.174200.105 |
WARNING: DEV current out of threshold 1. |
||
devOutOfThreshold2 | 1.3.6.1.4.1.174200.106 |
CRITICAL: DEV current out of threshold 2. |
||
devBackToNormal | 1.3.6.1.4.1.174200.108 |
NORMAL: DEV back to normal states |