Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 os10ChassisMib 1.3.6.1.4.1.674.11000.5000.100.4
Dell EMC Networking OS10 Chassis MIB.
     os10SysObject 1.3.6.1.4.1.674.11000.5000.100.4.1
         os10ChassisObject 1.3.6.1.4.1.674.11000.5000.100.4.1.1
             os10NumChassis 1.3.6.1.4.1.674.11000.5000.100.4.1.1.1 unsigned32 read-only
The total number of chassis configured on the cluster.
             os10MaxNumChassis 1.3.6.1.4.1.674.11000.5000.100.4.1.1.2 unsigned32 read-only
Indicates the maximum allowed chassis configurable on the cluster.
             os10ChassisTable 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3 no-access
A list of chassis in a cluster. The chassis table contains the information of each chassis in the cluster.
                 os10ChassisEntry 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1 no-access
A list of chassis entries containing information for the chassis.
                     os10ChassisIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1 unsigned32 no-access
A unique index for each chassis within the cluster. This value is the chassisId assigned to the chassis.
                     os10ChassisType 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2 os10chassisdeftype read-only
The Dell EMC Networking Model number of the chassis.
                     os10ChassisMacAddr 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3 macaddress read-only
A 6-octet MAC Address assigned to this chassis.
                     os10ChassisPartNum 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4 displaystring read-only
The chassis manufacturer's part number.
                     os10ChassisPPID 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5 displaystring read-only
The chassis manufacturer's PPID.
                     os10ChassisHwRev 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6 displaystring read-only
The chassis hardware revision number.
                     os10ChassisServiceTag 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7 displaystring read-only
The chassis's service tag.
                     os10ChassisExpServiceCode 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8 displaystring read-only
The chassis's express service code.
                     os10ChassisNumFanTrays 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9 unsigned32 read-only
Number of fan trays in the chassis.
                     os10ChassisNumPowerSupplies 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10 unsigned32 read-only
Number of power supplies in the chassis.
                     os10ChassisTemp 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11 integer32 read-only
Temperature of the chassis.
                     os10ChassisProductBase 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12 displaystring read-only
The solution id product base
                     os10ChassisProductSN 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13 displaystring read-only
The solution id product serial number
                     os10ChassisProductPN 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14 displaystring read-only
The solution id product part number
             os10CardTable 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4 no-access
A list of line cards resident in the chassis. This table contains the information on each RPM and linecards in the chassis.
                 os10CardEntry 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1 no-access
Entry for each card in the chassis.
                     os10CardIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1 unsigned32 no-access
A unique index for each card in the chassis.
                     os10CardType 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2 os10systemcardtype read-only
Card's type.
                     os10CardDescription 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3 displaystring read-only
A short description of the card.
                     os10CardStatus 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4 os10cardoperstatus read-only
The current operational state of the card.
                     os10CardTemp 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5 integer32 read-only
Temperature of the card.
                     os10CardPartNum 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6 displaystring read-only
The card's part number
                     os10CardPPID 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7 displaystring read-only
The card's PPID.
                     os10CardHwRev 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8 displaystring read-only
The card's manufacturer hardware revision number.
                     os10CardServiceTag 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9 displaystring read-only
The card's service tag.
                     os10CardExpServiceCode 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10 displaystring read-only
The card's express service code.
         os10SystemComponent 1.3.6.1.4.1.674.11000.5000.100.4.1.2
             os10PowerSupplyTable 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1 no-access
A list of power supplies resident in the device.
                 os10PowerSupplyEntry 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1 no-access
A power supply entry provides all attributes of that power supply.
                     os10PowerSupplyIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1 unsigned32 no-access
The unique index of the power supply.
                     os10PowerSupplyDevice 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2 os10devicetype read-only
Identify the type of device the power supply unit resides (chassis,line card etc..)
                     os10PowerSupplyDeviceIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3 unsigned32 read-only
A unique value indentifying a specific os10PowerSupplyDeviceType.
                     os10PowerSupplyOperStatus 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4 os10cmnoperstatus read-only
The status of the power supply.
                     os10PowerSupplyType 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5 integer read-only
The type of the power supply. Enumeration: 'unknown': 1, 'ac': 2, 'dc': 3.
                     os10PowerSupplyPPID 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6 displaystring read-only
The power supply's PPID.
                     os10PowerSupplyServiceTag 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7 displaystring read-only
The power supply's service tag.
                     os10PowerSupplyExpServiceCode 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8 displaystring read-only
The power supply's express service code.
             os10FanTrayTable 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2 no-access
A list of fan trays resident in the device.
                 os10FanTrayEntry 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1 no-access
A fan entry containing objects for a particular fan tray.
                     os10FanTrayIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1 unsigned32 no-access
The unique index of the fan tray.
                     os10FanTrayDevice 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2 os10devicetype read-only
Identify the type of device this fan tray unit resides (chassis,line card etc..)
                     os10FanTrayDeviceIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3 unsigned32 read-only
A unique value indentifying a specific os10FanTrayDevice.
                     os10FanTrayOperStatus 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4 os10cmnoperstatus read-only
The status of the fan tray.
                     os10FanTrayPPID 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5 displaystring read-only
The fan tray's PPID.
                     os10FanTrayServiceTag 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6 displaystring read-only
The fan tray's service tag.
                     os10FanTrayExpServiceCode 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7 displaystring read-only
The fan tray's express service code.
             os10FanTable 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3 no-access
A list of fans installed in the chassis.
                 os10FanEntry 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1 no-access
A fan entry containing objects for a particular fan in the chassis.
                     os10FanIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1 unsigned32 no-access
The unique value for each fan in the device.
                     os10FanDevice 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2 os10devicetype read-only
Identify the type of device this fan resides. (chassis,line card etc..)
                     os10FanDeviceIndex 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3 unsigned32 read-only
A unique value indentifying a specific os10FanDevice.
                     os10FanEntity 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4 integer read-only
Identify the type of system componet where the fan is installed. Enumeration: 'fanTray': 2, 'ps': 1.
                     os10FanEntitySlot 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5 unsigned32 read-only
A unique value indentifying a specific os10FanEntity.
                     os10FanId 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6 unsigned32 read-only
A unique value indentifying a specific fan in a specific os10FanEntity.
                     os10FanOperStatus 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7 os10cmnoperstatus read-only
The status of the fan.
         os10AlmObjects 1.3.6.1.4.1.674.11000.5000.100.4.1.3
             os10AlmMibNotifications 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1
                 os10AlmMinorTempHigh 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.1
The agent generates this trap when the chassis's temperature is exceeding the minor threshold.
                 os10AlmMinorTempClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.2
The agent generates this trap when the chassis's temperature is within the minor threshold.
                 os10AlmMajorTempHigh 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.3
The agent generates this trap when the chassis's temperature is exceeding the mjaor threshold.
                 os10AlmMajorTempClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.4
The agent generates this trap when the chassis's temperature is within the mjaor threshold.
                 os10AlmPowerSupplyDown 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.5
The agent generates this trap when a power supply is not operational.
                 os10AlmPowerSupplyClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.6
The agent generates this trap when a power supply is now operational.
                 os10AlmMajorPowerSupply 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.7
The agent generates this trap when a power supply major alarm is issued.
                 os10AlmMajorPowerSupplyClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.8
The agent generates this trap when a power supply major alarm is cleared.
                 os10AlmMinorPowerSupply 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.9
The agent generates this trap when a power supply minor alarm is issued.
                 os10AlmMinorPowerSupplyClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.10
The agent generates this trap when a power supply minor alarm is cleared.
                 os10AlmFanTrayDown 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.11
The agent generates this trap when a fan tray is missing or not operational.
                 os10AlmFanTrayClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.12
The agent generates this trap when a fan tray is now operational.
                 os10AlmMinorFanTray 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.13
The agent generates this trap when a minor fan tray alarm is issued.
                 os10AlmMinorFanTrayClr 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.14
The agent generates this trap when a theminor fan tray alarm is cleared.
             os10AlmVariable 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2
                 os10AlmVarInteger 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.1 integer32 no-access
An generic integer value in the TRAP object
                 os10AlmVarString 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.2 octet string no-access
An generic string value in the TRAP object
                 os10AlmVarChassisId 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.3 integer32 no-access
The Chassis ID. For the traps that does not have Chassis information the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU.
                 os10AlmVarSlot 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.4 integer32 no-access
The chassis slot number. For the traps that does not have slot information the value will -1 in the TRAP PDU.
                 os10AlmVarPort 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.5 integer32 no-access
The chassis port number. For the traps that does not have port information the value will -1 in the TRAP PDU.