DELL-RAC-MIB: View SNMP OID List / Download MIB
VENDOR: DELL INC.
Home | MIB: DELL-RAC-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
dell | 1.3.6.1.4.1.674 | |||
server3 | 1.3.6.1.4.1.674.10892 | |||
drsOutofBandGroup | 1.3.6.1.4.1.674.10892.2 | |||
drsInformationGroup | 1.3.6.1.4.1.674.10892.2.1 | |||
drsProductInfoGroup | 1.3.6.1.4.1.674.10892.2.1.1 | |||
drsProductName | 1.3.6.1.4.1.674.10892.2.1.1.1 | dellstring | read-only |
0001.0001.0001 This attribute defines the product name of a chassis management controller. |
drsProductShortName | 1.3.6.1.4.1.674.10892.2.1.1.2 | dellstring | read-only |
0001.0001.0002 This attribute defines the short product name of a chassis management controller. |
drsProductDescription | 1.3.6.1.4.1.674.10892.2.1.1.3 | dellstring | read-only |
0001.0001.0003 This attribute defines the product description of a chassis management controller. |
drsProductManufacturer | 1.3.6.1.4.1.674.10892.2.1.1.4 | dellstring | read-only |
0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. |
drsProductVersion | 1.3.6.1.4.1.674.10892.2.1.1.5 | dellstring | read-only |
0001.0001.0005 This attribute defines the product version of a chassis management controller. |
drsChassisServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.6 | dellstring | read-only |
0001.0001.0007 This attribute defines the Service Tag of the chassis. |
drsProductURL | 1.3.6.1.4.1.674.10892.2.1.1.7 | dellstring | read-only |
0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. |
drsProductChassisAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.8 | dellstring | read-only |
0001.0001.0008 This attribute defines the Asset Tag of the chassis. |
drsProductChassisLocation | 1.3.6.1.4.1.674.10892.2.1.1.9 | dellstring | read-only |
0001.0001.0009 This attribute defines the location of the chassis. |
drsProductChassisName | 1.3.6.1.4.1.674.10892.2.1.1.10 | dellstring | read-only |
0001.0001.0010 This attribute defines the name of the chassis. |
drsSystemServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.11 | dellstring | read-only |
0001.0001.0011 This attribute defines the service tag of a system. |
drsProductSystemAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.12 | dellstring | read-only |
0001.0001.0012 This attribute defines the asset tag of a system. |
drsProductSystemSlot | 1.3.6.1.4.1.674.10892.2.1.1.13 | dellstring | read-only |
0001.0001.0013 This attribute defines the slot number of a CMC. |
drsProductType | 1.3.6.1.4.1.674.10892.2.1.1.14 | dellractype | read-only |
0001.0001.0014 This attribute defines type of a remote access card |
drsProductChassisDataCenter | 1.3.6.1.4.1.674.10892.2.1.1.15 | dellstring | read-only |
0001.0001.0015 This attribute defines the Data Center locator of the chassis. |
drsProductChassisAisle | 1.3.6.1.4.1.674.10892.2.1.1.16 | dellstring | read-only |
0001.0001.0016 This attribute defines the Aisle locator of the chassis. |
drsProductChassisRack | 1.3.6.1.4.1.674.10892.2.1.1.17 | dellstring | read-only |
0001.0001.0017 This attribute defines the Rack locator of the chassis. |
drsProductChassisRackSlot | 1.3.6.1.4.1.674.10892.2.1.1.18 | dellstring | read-only |
0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. |
drsProductChassisModel | 1.3.6.1.4.1.674.10892.2.1.1.19 | dellstring | read-only |
0001.0001.0019 This attribute defines the Model of the chassis. |
drsProductChassisExpressServiceCode | 1.3.6.1.4.1.674.10892.2.1.1.20 | dellstring | read-only |
0001.0001.0020 This attribute defines the Express Service Code of the chassis. |
drsProductChassisSystemID | 1.3.6.1.4.1.674.10892.2.1.1.21 | integer | read-only |
0001.0001.0021 This attribute defines the System ID of the chassis. |
drsProductChassisSize | 1.3.6.1.4.1.674.10892.2.1.1.22 | integer | read-only |
0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. |
drsFirmwareGroup | 1.3.6.1.4.1.674.10892.2.1.2 | |||
drsFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.1 | dellstring | read-only |
0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. |
drsiKVMFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.2 | dellstring | read-only |
0001.0002.0002 This attribute defines the firmware version of the iKVM. |
drsFirmwareVersion2 | 1.3.6.1.4.1.674.10892.2.1.2.3 | dellstring | read-only |
0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. |
drsStatusGroup | 1.3.6.1.4.1.674.10892.2.2 | |||
drsGlobalSystemStatus | 1.3.6.1.4.1.674.10892.2.2.1 | dellstatus | read-only |
0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
drsChassisStatusGroup | 1.3.6.1.4.1.674.10892.2.3 | |||
drsStatusNowGroup | 1.3.6.1.4.1.674.10892.2.3.1 | |||
drsGlobalCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.1 | dellstatus | read-only |
0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
drsIOMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.2 | dellstatus | read-only |
0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. |
drsKVMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.3 | dellstatus | read-only |
0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. |
drsRedCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.4 | dellstatus | read-only |
0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. |
drsPowerCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.5 | dellstatus | read-only |
0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. |
drsFanCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.6 | dellstatus | read-only |
0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. |
drsBladeCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.7 | dellstatus | read-only |
0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. |
drsTempCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.8 | dellstatus | read-only |
0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. |
drsCMCCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.9 | dellstatus | read-only |
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
drsChassisFrontPanelAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.10 | delltemperaturereading | read-only |
0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. |
drsCMCAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.11 | delltemperaturereading | read-only |
0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. |
drsCMCProcessorTemperature | 1.3.6.1.4.1.674.10892.2.3.1.12 | delltemperaturereading | read-only |
0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. |
drsStatusPrevGroup | 1.3.6.1.4.1.674.10892.2.3.2 | |||
drsGlobalPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.1 | dellstatus | read-only |
0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. |
drsIOMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.2 | dellstatus | read-only |
0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. |
drsKVMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.3 | dellstatus | read-only |
0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. |
drsRedPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.4 | dellstatus | read-only |
0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. |
drsPowerPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.5 | dellstatus | read-only |
0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. |
drsFanPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.6 | dellstatus | read-only |
0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. |
drsBladePrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.7 | dellstatus | read-only |
0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. |
drsTempPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.8 | dellstatus | read-only |
0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. |
drsCMCPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.9 | dellstatus | read-only |
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
drsStatusChangeGroup | 1.3.6.1.4.1.674.10892.2.3.3 | |||
drsGlobalChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.1 | timeticks | read-only |
0003.0003.0001 This attribute defines the timestamp of the most recent global status change. |
drsIOMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.2 | timeticks | read-only |
0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. |
drsKVMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.3 | timeticks | read-only |
0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. |
drsRedChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.4 | timeticks | read-only |
0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. |
drsPowerChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.5 | timeticks | read-only |
0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. |
drsFanChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.6 | timeticks | read-only |
0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. |
drsBladeChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.7 | timeticks | read-only |
0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. |
drsTempChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.8 | timeticks | read-only |
0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. |
drsCMCChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.9 | timeticks | read-only |
0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. |
drsChassisPowerGroup | 1.3.6.1.4.1.674.10892.2.4 | |||
drsCMCPowerTable | 1.3.6.1.4.1.674.10892.2.4.1 | no-access |
0004.0001 This object defines the CMC power table. |
|
1.3.6.1.4.1.674.10892.2.4.1.1 | no-access |
0004.0001.0001 This object defines the CMC power table entry. |
||
drsChassisIndex | 1.3.6.1.4.1.674.10892.2.4.1.1.1 | dellcmcpowerindexrange | read-only |
0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
drsPotentialPower | 1.3.6.1.4.1.674.10892.2.4.1.1.2 | dellpowerreading | read-only |
0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers. |
drsIdlePower | 1.3.6.1.4.1.674.10892.2.4.1.1.3 | dellpowerreading | read-only |
0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. |
drsMaxPowerSpecification | 1.3.6.1.4.1.674.10892.2.4.1.1.4 | dellpowerreading | read-only |
0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. |
drsPowerSurplus | 1.3.6.1.4.1.674.10892.2.4.1.1.5 | dellpowerreading | read-only |
0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. |
drsKWhCumulative | 1.3.6.1.4.1.674.10892.2.4.1.1.6 | dellpowerreading | read-only |
0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
drsKWhCumulativeTime | 1.3.6.1.4.1.674.10892.2.4.1.1.7 | delltimestamp | read-only |
0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. |
drsWattsPeakUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.8 | dellpowerreading | read-only |
0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. |
drsWattsPeakTime | 1.3.6.1.4.1.674.10892.2.4.1.1.9 | delltimestamp | read-only |
0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. |
drsWattsMinUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.10 | dellpowerreading | read-only |
0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
drsWattsMinTime | 1.3.6.1.4.1.674.10892.2.4.1.1.11 | delltimestamp | read-only |
0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. |
drsWattsResetTime | 1.3.6.1.4.1.674.10892.2.4.1.1.12 | delltimestamp | read-only |
0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. |
drsWattsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.13 | dellpowerreading | read-only |
0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). |
drsAmpsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.14 | dellpowerreading | read-only |
0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). |
drsCMCPSUTable | 1.3.6.1.4.1.674.10892.2.4.2 | no-access |
0004.0002 This object defines the CMC PSU table. |
|
1.3.6.1.4.1.674.10892.2.4.2.1 | no-access |
0004.0002.0001 This object defines the CMC PSU table entry. |
||
drsPSUChassisIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.1 | dellcmcpowerindexrange | read-only |
0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
drsPSUIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.2 | dellcmcpsuindexrange | read-only |
0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. |
drsPSULocation | 1.3.6.1.4.1.674.10892.2.4.2.1.3 | dellstring | read-only |
0004.0002.0001.0003 This attribute defines the location of the CMC PSU. |
drsPSUMonitoringCapable | 1.3.6.1.4.1.674.10892.2.4.2.1.4 | dellcmcpsucapable | read-only |
0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. |
drsPSUVoltsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.5 | dellpowerreading | read-only |
0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. |
drsPSUAmpsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.6 | dellpowerreading | read-only |
0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. |
drsPSUWattsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.7 | dellpowerreading | read-only |
0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. |
drsChassisServerGroup | 1.3.6.1.4.1.674.10892.2.5 | |||
drsCMCServerTable | 1.3.6.1.4.1.674.10892.2.5.1 | no-access |
0005.0001 This object defines the CMC server table. |
|
1.3.6.1.4.1.674.10892.2.5.1.1 | no-access |
0005.0001.0001 This object defines the CMC server table entry. |
||
drsServerIndex | 1.3.6.1.4.1.674.10892.2.5.1.1.1 | dellcmcserverindexrange | read-only |
0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. |
drsServerMonitoringCapable | 1.3.6.1.4.1.674.10892.2.5.1.1.2 | dellcmcservercapable | read-only |
0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. |
drsServerServiceTag | 1.3.6.1.4.1.674.10892.2.5.1.1.3 | dellstring | read-only |
0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. |
drsServerSlotName | 1.3.6.1.4.1.674.10892.2.5.1.1.4 | dellstring | read-only |
0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. |
drsServerSlotNumber | 1.3.6.1.4.1.674.10892.2.5.1.1.5 | dellstring | read-only |
0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. |
drsServerNodeID | 1.3.6.1.4.1.674.10892.2.5.1.1.6 | dellstring | read-only |
0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. |
drsCMCAlertGroup | 1.3.6.1.4.1.674.10892.2.20 | |||
drsChassisAlertVariables | 1.3.6.1.4.1.674.10892.2.20.10 | |||
drsCASubSystem | 1.3.6.1.4.1.674.10892.2.20.10.1 | dellstring | read-only |
0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert |
drsCASSCurrStatus | 1.3.6.1.4.1.674.10892.2.20.10.2 | dellstatus | read-only |
0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System |
drsCASSPrevStatus | 1.3.6.1.4.1.674.10892.2.20.10.3 | dellstatus | read-only |
0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System |
drsCASSChangeTime | 1.3.6.1.4.1.674.10892.2.20.10.4 | timeticks | read-only |
0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System |
drsCAMessage | 1.3.6.1.4.1.674.10892.2.20.10.5 | dellstring | read-only |
0020.0010.0005 This attribute defines the CSSD message of the CMC Alert |
drsCMCAlert2Group | 1.3.6.1.4.1.674.10892.2.21 | |||
drsChassisAlert2Variables | 1.3.6.1.4.1.674.10892.2.21.10 | |||
drsCA2MessageID | 1.3.6.1.4.1.674.10892.2.21.10.1 | displaystring | read-only |
Message ID of the alert. |
drsCA2Message | 1.3.6.1.4.1.674.10892.2.21.10.2 | dellstring | read-only |
Message describing the alert. |
drsCA2MessageArgs | 1.3.6.1.4.1.674.10892.2.21.10.3 | dellstring | read-only |
Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes. |
drsCA2AlertStatus | 1.3.6.1.4.1.674.10892.2.21.10.4 | dellstatus | read-only |
Status of the alert. |
drsCA2FQDD | 1.3.6.1.4.1.674.10892.2.21.10.5 | displaystring | read-only |
Fully qualified device descriptor of device causing the alert. |
alert2FanFailure | 1.3.6.1.4.1.674.10892.2.210.2153 |
Fan failure. |
||
alert2FanWarning | 1.3.6.1.4.1.674.10892.2.210.2154 |
Fan warning. |
||
alert2FanInformation | 1.3.6.1.4.1.674.10892.2.210.2155 |
Fan information. |
||
alert2TemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.210.2161 |
Temperature sensor has detected a failure value. |
||
alert2TemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.210.2162 |
Temperature sensor has detected a warning value. |
||
alert2TemperatureProbeNormal | 1.3.6.1.4.1.674.10892.2.210.2163 |
Temperature sensor value is within range. |
||
alert2VoltageProbeFailure | 1.3.6.1.4.1.674.10892.2.210.2169 |
Voltage sensor has detected a failure value. |
||
alert2VoltageProbeWarning | 1.3.6.1.4.1.674.10892.2.210.2170 |
Voltage sensor has detected a warning value. |
||
alert2VoltageProbeNormal | 1.3.6.1.4.1.674.10892.2.210.2171 |
Voltage sensor reading is within range. |
||
alert2AmperageProbeFailure | 1.3.6.1.4.1.674.10892.2.210.2177 |
Current sensor has detected a failure value. |
||
alert2AmperageProbeWarning | 1.3.6.1.4.1.674.10892.2.210.2178 |
Current sensor has detected a warning value. |
||
alert2AmperageProbeNormal | 1.3.6.1.4.1.674.10892.2.210.2179 |
Current sensor reading is within range. |
||
alert2PowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.210.2185 |
Power supply has detected a failure. |
||
alert2PowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.210.2186 |
Power supply has detected a warning. |
||
alert2PowerSupplyNormal | 1.3.6.1.4.1.674.10892.2.210.2187 |
Power supply has returned to normal. |
||
alert2BatteryFailure | 1.3.6.1.4.1.674.10892.2.210.2225 |
Battery has failed or battery is absent. |
||
alert2BatteryWarning | 1.3.6.1.4.1.674.10892.2.210.2226 |
Battery is low. |
||
alert2BatteryNormal | 1.3.6.1.4.1.674.10892.2.210.2227 |
Battery state has returned to normal; or battery presence had been detected. |
||
alert2LinkStatusFailure | 1.3.6.1.4.1.674.10892.2.210.2249 |
Link status failure or critical event. |
||
alert2LinkStatusWarning | 1.3.6.1.4.1.674.10892.2.210.2250 |
Link status warning. |
||
alert2LinkStatusInformation | 1.3.6.1.4.1.674.10892.2.210.2251 |
Link status information. |
||
alert2PowerUsageWarning | 1.3.6.1.4.1.674.10892.2.210.2274 |
Power usage warning. |
||
alert2PowerUsageInformation | 1.3.6.1.4.1.674.10892.2.210.2275 |
Power usage information. |
||
alert2HardwareConfigurationFailure | 1.3.6.1.4.1.674.10892.2.210.2329 |
Hardware configuration failure or critical event. |
||
alert2HardwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.210.2330 |
Hardware configuration warning. |
||
alert2HardwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.210.2331 |
Hardware configuration information. |
||
alert2SoftwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.210.2338 |
Software configuration warning. |
||
alert2SoftwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.210.2339 |
Software configuration information. |
||
alert2SystemEventLogFailure | 1.3.6.1.4.1.674.10892.2.210.2377 |
System Event Log failure or critical event. |
||
alert2SystemEventLogWarning | 1.3.6.1.4.1.674.10892.2.210.2378 |
System Event Log warning. |
||
alert2SystemEventLogInformation | 1.3.6.1.4.1.674.10892.2.210.2379 |
System Event Log information. |
||
alert2SecurityFailure | 1.3.6.1.4.1.674.10892.2.210.2385 |
Security failure or critical event. |
||
alert2SecurityWarning | 1.3.6.1.4.1.674.10892.2.210.2386 |
Security warning. |
||
alert2SecurityInformation | 1.3.6.1.4.1.674.10892.2.210.2387 |
Security information. |
||
alert2CableFailure | 1.3.6.1.4.1.674.10892.2.210.2393 |
Cable failure. |
||
alert2PCIDeviceFailure | 1.3.6.1.4.1.674.10892.2.210.2417 |
PCI device failure or critical event. |
||
alert2PCIDeviceWarning | 1.3.6.1.4.1.674.10892.2.210.2418 |
PCI device warning. |
||
alert2PCIDeviceInformation | 1.3.6.1.4.1.674.10892.2.210.2419 |
PCI device information. |
||
alert2PowerSupplyAbsent | 1.3.6.1.4.1.674.10892.2.210.2465 |
Power supply is absent. |
||
alert2RedundancyLost | 1.3.6.1.4.1.674.10892.2.210.2473 |
Redundancy is lost. |
||
alert2RedundancyDegraded | 1.3.6.1.4.1.674.10892.2.210.2474 |
Redundancy is degraded. |
||
alert2RedundancyInformation | 1.3.6.1.4.1.674.10892.2.210.2475 |
Redundancy information. |
||
alert2CMCFailure | 1.3.6.1.4.1.674.10892.2.210.2545 |
Chassis Management Controller detected an error. |
||
alert2CMCWarning | 1.3.6.1.4.1.674.10892.2.210.2546 |
Chassis Management Controller detected a warning. |
||
alert2IOVirtualizationFailure | 1.3.6.1.4.1.674.10892.2.210.2553 |
IO Virtualization failure or critical event. |
||
alert2IOVirtualizationWarning | 1.3.6.1.4.1.674.10892.2.210.2554 |
IO Virtualization warning. |
||
alert2IOVirtualizationInformation | 1.3.6.1.4.1.674.10892.2.210.2555 |
IO Virtualization information. |
||
alert2StorageManagementFailure | 1.3.6.1.4.1.674.10892.2.210.4177 |
Storage Management has detected a device independent error condition. There is no global status change associated with this trap. |
||
alert2StorageManagementWarning | 1.3.6.1.4.1.674.10892.2.210.4178 |
Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. |
||
alert2StorageManagementInformation | 1.3.6.1.4.1.674.10892.2.210.4179 |
Storage Management information. There is no global status change associated with this trap. |
||
alert2StorageFanFailure | 1.3.6.1.4.1.674.10892.2.210.4201 |
Storage Fan failure. |
||
alert2StorageFanWarning | 1.3.6.1.4.1.674.10892.2.210.4202 |
Storage Fan warning. |
||
alert2StorageFanInformation | 1.3.6.1.4.1.674.10892.2.210.4203 |
Storage Fan information. |
||
alert2StorageTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.210.4209 |
Storage Temperature probe failure. |
||
alert2StorageTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.210.4210 |
Storage Temperature probe warning. |
||
alert2StorageTemperatureProbeInformation | 1.3.6.1.4.1.674.10892.2.210.4211 |
Storage Temperature probe information. |
||
alert2StoragePowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.210.4233 |
Storage Power supply failure. |
||
alert2StoragePowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.210.4234 |
Storage Power supply warning. |
||
alert2StoragePowerSupplyInformation | 1.3.6.1.4.1.674.10892.2.210.4235 |
Storage Power supply information. |
||
alert2StorageBatteryFailure | 1.3.6.1.4.1.674.10892.2.210.4273 |
Storage Battery failure. |
||
alert2StorageBatteryWarning | 1.3.6.1.4.1.674.10892.2.210.4274 |
Storage Battery warning. |
||
alert2StorageBatteryInformation | 1.3.6.1.4.1.674.10892.2.210.4275 |
Storage Battery information. |
||
alert2StorageControllerFailure | 1.3.6.1.4.1.674.10892.2.210.4329 |
Storage Controller failure. |
||
alert2StorageControllerWarning | 1.3.6.1.4.1.674.10892.2.210.4330 |
Storage Controller warning. |
||
alert2StorageControllerInformation | 1.3.6.1.4.1.674.10892.2.210.4331 |
Storage Controller information. |
||
alert2StorageEnclosureFailure | 1.3.6.1.4.1.674.10892.2.210.4337 |
Storage Enclosure failure. |
||
alert2StorageEnclosureWarning | 1.3.6.1.4.1.674.10892.2.210.4338 |
Storage Enclosure warning. |
||
alert2StorageEnclosureInformation | 1.3.6.1.4.1.674.10892.2.210.4339 |
Storage Enclosure information. |
||
alert2StoragePhysicalDiskFailure | 1.3.6.1.4.1.674.10892.2.210.4345 |
Storage Physical disk failure. |
||
alert2StoragePhysicalDiskWarning | 1.3.6.1.4.1.674.10892.2.210.4346 |
Storage Physical disk warning. |
||
alert2StoragePhysicalDiskInformation | 1.3.6.1.4.1.674.10892.2.210.4347 |
Storage Physical disk information. |
||
alert2StorageVirtualDiskFailure | 1.3.6.1.4.1.674.10892.2.210.4353 |
Storage Virtual disk failure. |
||
alert2StorageVirtualDiskWarning | 1.3.6.1.4.1.674.10892.2.210.4354 |
Storage Virtual disk warning. |
||
alert2StorageVirtualDiskInformation | 1.3.6.1.4.1.674.10892.2.210.4355 |
Storage Virtual disk information. |
||
alert2PowerSupplyAuditFailure | 1.3.6.1.4.1.674.10892.2.210.8329 |
Power Supply audit failure or critical event. |
||
alert2PowerSupplyAuditWarning | 1.3.6.1.4.1.674.10892.2.210.8330 |
Power Supply audit warning. |
||
alert2SoftwareChangeAuditFailure | 1.3.6.1.4.1.674.10892.2.210.8361 |
Software change audit failure or critical event. |
||
alert2PowerUsageAuditFailure | 1.3.6.1.4.1.674.10892.2.210.8417 |
Power usage audit failure or critical event. |
||
alert2PowerUsageAuditWarning | 1.3.6.1.4.1.674.10892.2.210.8418 |
Power usage audit warning. |
||
alert2LicenseFailure | 1.3.6.1.4.1.674.10892.2.210.8513 |
License failure. |
||
alert2LicenseWarning | 1.3.6.1.4.1.674.10892.2.210.8514 |
License warning. |
||
alert2LicenseInformation | 1.3.6.1.4.1.674.10892.2.210.8515 |
License information. |
||
alert2PCIDeviceAuditWarning | 1.3.6.1.4.1.674.10892.2.210.8562 |
PCI device audit warning. |
||
alert2CMCAuditFailure | 1.3.6.1.4.1.674.10892.2.210.8689 |
Chassis Management Controller audit failure or critical event. |
||
alert2CMCAuditWarning | 1.3.6.1.4.1.674.10892.2.210.8690 |
Chassis Management Controller audit warning. |
||
alert2CMCAuditInformation | 1.3.6.1.4.1.674.10892.2.210.8691 |
Chassis Management Controller audit information. |
||
alert2IOVirtualizationAuditWarning | 1.3.6.1.4.1.674.10892.2.210.8698 |
IO Virtualization audit warning. |
||
alert2CMCTestTrap | 1.3.6.1.4.1.674.10892.2.210.10395 |
Test trap generated by CMC in response to a user request. |
||
alert2PCIDeviceConfigurationInformation | 1.3.6.1.4.1.674.10892.2.210.10611 |
PCI device configuration information. |
||
alert2IOVConfigurationWarning | 1.3.6.1.4.1.674.10892.2.210.10746 |
IO Virtualization configuration warning. |
||
alert2IOVConfigurationInformation | 1.3.6.1.4.1.674.10892.2.210.10747 |
IO Virtualization configuration information. |
||
drsAlertGroup | 1.3.6.1.4.1.674.10892.2.5000 | |||
drsAlertVariables | 1.3.6.1.4.1.674.10892.2.5000.10 | |||
drsAlertSystem | 1.3.6.1.4.1.674.10892.2.5000.10.1 | octet string | read-only |
5000.0010.0001 Name of the system generating the alert. |
drsAlertTableIndexOID | 1.3.6.1.4.1.674.10892.2.5000.10.2 | object identifier | read-only |
5000.0010.0002 0.0 |
drsAlertMessage | 1.3.6.1.4.1.674.10892.2.5000.10.3 | octet string | read-only |
5000.0010.0003 Message describing the alert. |
drsAlertCurrentStatus | 1.3.6.1.4.1.674.10892.2.5000.10.4 | dellstatus | read-only |
5000.0010.0004 Current status of object causing the alert. |
drsAlertPreviousStatus | 1.3.6.1.4.1.674.10892.2.5000.10.5 | dellstatus | read-only |
5000.0010.0005 Previous status of object causing the alert. |
drsAlertData | 1.3.6.1.4.1.674.10892.2.5000.10.6 | octet string | read-only |
5000.0010.0006 Alert data. |
alertDrscTestTrapEvent | 1.3.6.1.4.1.674.10892.20.1001 |
The RAC generated a test trap event in response to a user request. |
||
alertDrscAuthError | 1.3.6.1.4.1.674.10892.20.1002 |
The RAC Authentication Failures during a time period have Exceeded a Threshold. |
||
alertDrscLostESM | 1.3.6.1.4.1.674.10892.20.1003 |
The RAC cannot communicate with the baseboard management controller (ESM). |
||
alertDrscFoundESM | 1.3.6.1.4.1.674.10892.20.1004 |
The RAC is communicating normally with the baseboard management controller (ESM). |
||
alertDrscPowerOff | 1.3.6.1.4.1.674.10892.20.1005 |
The RAC has detected a System power state change to powered-off. |
||
alertDrscPowerOn | 1.3.6.1.4.1.674.10892.20.1006 |
The RAC has detected a system power state change to powered-on. |
||
alertDrscWatchdogExpired | 1.3.6.1.4.1.674.10892.20.1007 |
The RAC has detected that the system watchdog has expired indicating a system hang. |
||
alertDrscBattLow | 1.3.6.1.4.1.674.10892.20.1008 |
The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. |
||
alertDrscTempNormal | 1.3.6.1.4.1.674.10892.20.1009 |
The RAC Temperature probe has retured to a normal value. |
||
alertDrscTempWarning | 1.3.6.1.4.1.674.10892.20.1010 |
The RAC Temperature probe has detected a Warning value. |
||
alertDrscTempCritical | 1.3.6.1.4.1.674.10892.20.1011 |
The RAC Temperature probe has detected a failure (or critical) value. |
||
alertDrscVoltNormal | 1.3.6.1.4.1.674.10892.20.1012 |
The RAC voltage has returned to a normal value. |
||
alertDrscVoltWarning | 1.3.6.1.4.1.674.10892.20.1013 |
The RAC voltage probe has detected a warning value. |
||
alertDrscVoltCritical | 1.3.6.1.4.1.674.10892.20.1014 |
The RAC voltage probe has detected a failure (or critical) value. |
||
alertDrscSELWarning | 1.3.6.1.4.1.674.10892.20.1015 |
The RAC has detected a new event in the System Event Log with Severity: Warning. |
||
alertDrscSELCritical | 1.3.6.1.4.1.674.10892.20.1016 |
The RAC has detected a new event in the System Event Log with Severity: Critical. |
||
alertDrscSEL80percentFull | 1.3.6.1.4.1.674.10892.20.1017 |
The RAC has detected that the System Event Log is 80% full. |
||
alertDrscSEL90percentFull | 1.3.6.1.4.1.674.10892.20.1018 |
The RAC has detected that the System Event Log is 90% full. |
||
alertDrscSEL100percentFull | 1.3.6.1.4.1.674.10892.20.1019 |
The RAC has detected that the System Event Log is 100% full. |
||
alertDrscSELNormal | 1.3.6.1.4.1.674.10892.20.1020 |
The RAC has detected a new event in the System Event Log with Severity: Normal. |
||
alertCMCTestTrap | 1.3.6.1.4.1.674.10892.20.2000 |
The CMC has generated a test trap |
||
alertCMCNormalTrap | 1.3.6.1.4.1.674.10892.20.2002 |
The CMC reported a return-to-normal or informational event. |
||
alertCMCWarningTrap | 1.3.6.1.4.1.674.10892.20.2003 |
The CMC reported a warning event. |
||
alertCMCCriticalTrap | 1.3.6.1.4.1.674.10892.20.2004 |
The CMC reported a critical event. |
||
alertCMCNonRecoverableTrap | 1.3.6.1.4.1.674.10892.20.2005 |