Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 swDdmMIB 1.3.6.1.4.1.171.12.72
The structure of DDM for the proprietary enterprise.
       swDdmCtrl 1.3.6.1.4.1.171.12.72.1
           swDdmTrapState 1.3.6.1.4.1.171.12.72.1.1 integer read-write
This object indicates the trap action state. Enumeration: 'disabled': 2, 'enabled': 1.
           swDdmLogState 1.3.6.1.4.1.171.12.72.1.2 integer read-write
This object indicates the log action state. Enumeration: 'disabled': 2, 'enabled': 1.
       swDdmInfo 1.3.6.1.4.1.171.12.72.2
           swDdmStatus 1.3.6.1.4.1.171.12.72.2.1
               swDdmStatusTable 1.3.6.1.4.1.171.12.72.2.1.1 no-access
This table contains the DDM status information.
                   swDdmStatusEntry 1.3.6.1.4.1.171.12.72.2.1.1.1 no-access
This is an entry of the swDdmStatusTable.
                       swDdmPort 1.3.6.1.4.1.171.12.72.2.1.1.1.1 integer read-only
This object indicates the port.
                       swDdmTemperature 1.3.6.1.4.1.171.12.72.2.1.1.1.2 displaystring read-only
This object indicates the real time value of the temperature. As the value is a floating point data type, the DisplayString type is used to define this parameter.
                       swDdmVoltage 1.3.6.1.4.1.171.12.72.2.1.1.1.3 displaystring read-only
This object indicates the real time value of the supply voltage. As the value value is a floating point data type, the DisplayString type is used to define this parameter.
                       swDdmBiasCurrent 1.3.6.1.4.1.171.12.72.2.1.1.1.4 displaystring read-only
This object indicates the real time value of the tx bias.
                       swDdmTxPower 1.3.6.1.4.1.171.12.72.2.1.1.1.5 displaystring read-only
This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
                       swDdmRxPower 1.3.6.1.4.1.171.12.72.2.1.1.1.6 displaystring read-only
This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
       swDdmMgmt 1.3.6.1.4.1.171.12.72.3
           swDdmThresholdMgmt 1.3.6.1.4.1.171.12.72.3.1
               swDdmThresholdMgmtTable 1.3.6.1.4.1.171.12.72.3.1.1 no-access
This table contains DDM temperature configuration information.
                   swDdmThresholdMgmtEntry 1.3.6.1.4.1.171.12.72.3.1.1.1 no-access
This is an entry of the swDdmConfigThresholdTable.
                       swDdmThresholdType 1.3.6.1.4.1.171.12.72.3.1.1.1.1 integer read-only
This object indicates the threshold type. Enumeration: 'txPower': 4, 'bias': 3, 'temperature': 1, 'rxPower': 5, 'voltage': 2.
                       swDdmHighAlarm 1.3.6.1.4.1.171.12.72.3.1.1.1.2 displaystring read-write
This object indicates the high alarm threshold value to be configured. As the value is a floating point data type, the DisplayString type is used to define this parameter.
                       swDdmLowAlarm 1.3.6.1.4.1.171.12.72.3.1.1.1.3 displaystring read-write
This object indicates the low alarm threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
                       swDdmHighWarning 1.3.6.1.4.1.171.12.72.3.1.1.1.4 displaystring read-write
This object indicates the high warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
                       swDdmLowWarning 1.3.6.1.4.1.171.12.72.3.1.1.1.5 displaystring read-write
This object indicates the low warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
           swDdmActionMgmt 1.3.6.1.4.1.171.12.72.3.2
               swDdmActionMgmtTable 1.3.6.1.4.1.171.12.72.3.2.1 no-access
This table contains the configuration of the action taken when any parameter exceeds its threshold.
                   swDdmActionMgmtEntry 1.3.6.1.4.1.171.12.72.3.2.1.1 no-access
This is an entry of the swDdmConfigActionTable.
                       swDdmActionType 1.3.6.1.4.1.171.12.72.3.2.1.1.1 integer read-only
This object indicates the action type. Enumeration: 'alarm': 1, 'warning': 2.
                       swDdmShutdown 1.3.6.1.4.1.171.12.72.3.2.1.1.2 integer read-write
This object indicates the shutdown action. The value 'other' means that the port does not support DDM. Enumeration: 'disabled': 2, 'other': 3, 'enabled': 1.
                       swDdmTrapAndLog 1.3.6.1.4.1.171.12.72.3.2.1.1.3 integer read-write
This object indicates the trap and log action. The value 'other' means that the port does not support DDM. Enumeration: 'disabled': 2, 'other': 3, 'enabled': 1.
               swDdmPortMgmtTable 1.3.6.1.4.1.171.12.72.3.2.2 no-access
This table contains the configuration of the DDM state and shutdown mode when any parameter exceeds its threshold.
                   swDdmPortMgmtEntry 1.3.6.1.4.1.171.12.72.3.2.2.1 no-access
This is an entry of the swDdmPortMgmtTable.
                       swDdmPortState 1.3.6.1.4.1.171.12.72.3.2.2.1.1 integer read-write
This object indicates the DDM state information by port. Enumeration: 'disabled': 2, 'enabled': 1.
                       swDdmPortShutdown 1.3.6.1.4.1.171.12.72.3.2.2.1.2 integer read-write
This object indicates whether or not to shutdown the port on which the operating parameter exceeds the specified threshold. Enumeration: 'other': 4, 'alarm': 1, 'warning': 2, 'none': 3.
       swDdmNotify 1.3.6.1.4.1.171.12.72.4
           swDdmNotifyPrefix 1.3.6.1.4.1.171.12.72.4.0
               swDdmAlarmTrap 1.3.6.1.4.1.171.12.72.4.0.1
The trap is sent when any parameter value exceeds the alarm threshold value or recover to normal status depending on the configuration of the trap action.
               swDdmWarningTrap 1.3.6.1.4.1.171.12.72.4.0.2
The trap is sent when any parameter value exceeds the warning threshold value or recover to normal status depending on the configuration of the trap action.
           swDdmNotificationBinding 1.3.6.1.4.1.171.12.72.4.1
               swDdmThresholdExceedType 1.3.6.1.4.1.171.12.72.4.1.1 integer no-access
This object is used by swDdmAlarmTrap and swDdmWarningTrap to indicate if the threshold that was exceeded was a high threshold or a low threshold. Enumeration: 'high': 1, 'low': 2.
               swDdmThresholdExceedOrRecover 1.3.6.1.4.1.171.12.72.4.1.2 integer no-access
This object is used by swDdmAlarmTrap and swDdmWarningTrap,to indicate the GBIC is exceeding its ddm threshold or recover to normal status. Enumeration: 'exceed': 1, 'recover': 2.