Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 david 1.3.6.1.4.1.66
       products 1.3.6.1.4.1.66.1
           davidExpressNet 1.3.6.1.4.1.66.1.3
               exNetChassis 1.3.6.1.4.1.66.1.3.1
                   exNetChassisType 1.3.6.1.4.1.66.1.3.1.1 integer read-only
The chassis type (option). Enumeration: 'reserved': 8, 'm6318st': 6, 'm6310tel': 4, 'other': 1, 'm6103': 3, 'm6102': 2, 'm6318sma': 7, 'm6310rj': 5.
                   exNetChassisBkplType 1.3.6.1.4.1.66.1.3.1.2 integer read-only
The chassis backplane type (option). Enumeration: 'other': 1, 'reserved': 3, 'expressNet': 2.
                   exNetChassisBkplRev 1.3.6.1.4.1.66.1.3.1.3 integer read-only
The chassis backplane revision.
                   exNetChassisPsType 1.3.6.1.4.1.66.1.3.1.4 integer read-only
The chassis power supply type. This refers to the chassis transformer. Each module (including the Supervisor Module) has its own switching power supply. Enumeration: 'other': 1, 'standardXfmr': 2.
                   exNetChassisPsStatus 1.3.6.1.4.1.66.1.3.1.5 integer read-only
The chassis power supply status. This refers t othe chassis transformer. Each module (including the Supervisor Module) has its own switching power supply. The status of the individual modules' power supplies is a module attribute. Enumeration: 'failed': 2, 'ok': 1.
                   exNetSlotConfigTable 1.3.6.1.4.1.66.1.3.1.7 no-access
The chassis slot configuration table.
                       exNetSlotConfigEntry 1.3.6.1.4.1.66.1.3.1.7.1 no-access
Descriptions of the modules (or boards) in each slot.
                           exNetSlotIndex 1.3.6.1.4.1.66.1.3.1.7.1.1 integer read-only
The DAVID ExpressNet chassis slot number. Valid entries are 1 to exNetChassisCapacity. On the physical Concentrator boxes, the Supervisor Modules are not numbered and the plug-in modules are numbered from 1 to n-1, where n is the number of slots in the Concentrator. For the purposes of the DAVID ExpressNet SNMP MIB, the Supervisor Module is numbered one past the highest-numbered plug-in module. For example, in a 12-Slot Concentrator, the plug-in modules are numbered 1-11 and the Supervisor Module is numbered 12.
                           exNetBoardId 1.3.6.1.4.1.66.1.3.1.7.1.2 integer read-only
The unique hardware ID for the module.
                           exNetBoardType 1.3.6.1.4.1.66.1.3.1.7.1.3 integer read-only
The type of the module. Enumeration: 'm6312': 6, 'm6311': 5, 'm6313st': 7, 'm6201': 4, 'm6203': 3, 'other': 2, 'm6313sma': 8, 'm6006': 9, 'reserved': 10, 'empty': 1.
                           exNetBoardDescr 1.3.6.1.4.1.66.1.3.1.7.1.4 displaystring read-only
Textual description of the module type.
                           exNetBoardNumOfPorts 1.3.6.1.4.1.66.1.3.1.7.1.40 integer read-only
The number of ports supported by the plug-in module. For a 10BASE-T Module the value is 12; for an FOIRL Module, 6; for a Supervisor Module, 1.
                   exNetChassisCapacity 1.3.6.1.4.1.66.1.3.1.8 integer read-only
The number of slots in the chassis for plug-in modules. This number will be either five or twelve for a Concentrator and two for a Hub.
               exNetEthernet 1.3.6.1.4.1.66.1.3.2
                   exNetConcentrator 1.3.6.1.4.1.66.1.3.2.1
                       exNetConcRetimingStatus 1.3.6.1.4.1.66.1.3.2.1.1 integer read-only
Indicates whether this repeater has retiming turned on. All DAVID ExpressNet repeaters implement retiming, so the value on(2) is always returned for this variable. Enumeration: 'on': 2, 'off': 1.
                       exNetConcFrmsRxOk 1.3.6.1.4.1.66.1.3.2.1.2 counter read-only
A count of frames that are successfully received by the Concentrator. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received.
                       exNetConcOctetsRxOk 1.3.6.1.4.1.66.1.3.2.1.3 counter read-only
A count of data and padding octets in frames that are successfully received by the concentrator. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received.
                       exNetConcMcastFrmsRxOk 1.3.6.1.4.1.66.1.3.2.1.4 counter read-only
A count of frames that are successfully received by the concentrator and are directed to an active non-broadcast group address. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. Only frames that are for a multicast address that this interface is receiving are counted. Broadcast packets are not included.
                       exNetConcBcastFrmsRxOk 1.3.6.1.4.1.66.1.3.2.1.5 counter read-only
A count of frames that are successfully received by the concentrator and are directed to the broadcast group address. This counter does not include frames received with frame-too- long, runt, FCS, or alignment errors. Multicast packets are not included.
                       exNetConcColls 1.3.6.1.4.1.66.1.3.2.1.6 counter read-only
Total collisions involving an incoming packet on any port (link or Network Interface port) in the Concentrator. This counter increments once for each collision involving an incoming packet on any port, no matter how many ports are involved.
                       exNetConcTooLongErrors 1.3.6.1.4.1.66.1.3.2.1.7 counter read-only
A count of frames that are received by the Concentrator and exceed the maximum permitted frame size.
                       exNetConcRuntErrors 1.3.6.1.4.1.66.1.3.2.1.8 counter read-only
Number of frames received by the Concentrator that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes (512 bits). Runts are commonly collision fragments, and as such do not necessarily indicate a problem in the network. Runts are also known as 'short frames.'
                       exNetConcFragErrors 1.3.6.1.4.1.66.1.3.2.1.9 counter read-only
Fragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on the Concentrator. Fragments indicate an external noise hit (a problem on the network). Fragments are also known as 'pygmies.'
                       exNetConcAlignErrors 1.3.6.1.4.1.66.1.3.2.1.10 counter read-only
Number of frames received on the Concentrator that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the frame check sequence check, but are not counted as FCS errors.)
                       exNetConcFcsErrors 1.3.6.1.4.1.66.1.3.2.1.11 counter read-only
A count of frames received by the Concentrator that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. FCS errors are sometimes called CRC errors.
                       exNetConcLateCollErrors 1.3.6.1.4.1.66.1.3.2.1.12 counter read-only
A total Concentrator count of the late collisions. The late collision counter for a port is incremented whenever a collision is detected on the port later than 512 bit times into the transmitted packet. Late collisions are not included in the collision count.
                       exNetConcName 1.3.6.1.4.1.66.1.3.2.1.40 displaystring read-write
A descriptive string that can be used by a network administrator to name the Concentrator.
                       exNetConcJabbers 1.3.6.1.4.1.66.1.3.2.1.41 counter read-only
A count of the number of times that the jabber function had to be invoked because a frame received from one of this Concentrator's ports exceeded 5 msec in duration.
                       exNetConcSfdErrors 1.3.6.1.4.1.66.1.3.2.1.42 counter read-only
Amount of activity from this Concentrator's ports where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity problem.)
                       exNetConcAutoPartitions 1.3.6.1.4.1.66.1.3.2.1.43 counter read-only
Indicates how often ports on this Concentrator have been automatically partitioned by the Concentrator repeater function.
                       exNetConcOosBitRate 1.3.6.1.4.1.66.1.3.2.1.44 counter read-only
Number of times that frames have been received on the Concentrator with the transmission frequency (data rate) badly out of spec. This counter is incremented when the frequency of a received frame is so far out of spec that the packet has been corrupted within the relay. The spec allows deviations of +/- 100 parts per million (ppm). The DAVID ExpressNet Intelligent Concentrators can handle greater deviations than this, depending on frame length.
                       exNetConcLinkErrors 1.3.6.1.4.1.66.1.3.2.1.45 counter read-only
This composite counter includes jabbers, auto-partitions, and start-frame delimiter errors.
                       exNetConcFrameErrors 1.3.6.1.4.1.66.1.3.2.1.46 counter read-only
This composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
                       exNetConcNetUtilization 1.3.6.1.4.1.66.1.3.2.1.47 octet string read-only
A series of ten bytes, each indicating the percentage of bandwidth utilization for a 100-millisecond interval. Together they give the bandwidth utilization for the previous second.
                       exNetConcResetTimeStamp 1.3.6.1.4.1.66.1.3.2.1.48 gauge read-only
The value of sysUpTime at the point that the Concentrator repeater state machine was last reset.
                       exNetConcReset 1.3.6.1.4.1.66.1.3.2.1.49 integer read-write
The reset state of the Concentrator's repeater state machine. Writing a 2 will reset the Concentrator's control logic, without changing the current configuration. Writing a 3 will reset the Concentrator to the initial factory default configuration. Enumeration: 'reset': 2, 'resetToDefault': 3, 'noReset': 1.
                   exNetModule 1.3.6.1.4.1.66.1.3.2.2
                       exNetModuleTable 1.3.6.1.4.1.66.1.3.2.2.1 no-access
A list of module entries. The number of entries is given by the number of modules that are obtained by the Concentrator Slot Configuration Table.
                           exNetModuleEntry 1.3.6.1.4.1.66.1.3.2.2.1.1 no-access
A module entry containing objects at the module level for a particular module.
                               exNetModuleIndex 1.3.6.1.4.1.66.1.3.2.2.1.1.1 integer read-only
A unique value for each module. Its value ranges between 1 and exNetChassisCapacity. The value for each module must remain constant at least from one reinitialization of the entity's network management system to the next reinitialization. This value is tied to the hardware chassis slot number.
                               exNetModuleType 1.3.6.1.4.1.66.1.3.2.2.1.1.2 integer read-only
The type of the module. Enumeration: 'm6312': 6, 'm6311': 5, 'm6313st': 7, 'm6201': 4, 'm6203': 3, 'other': 2, 'm6313sma': 8, 'm6006': 9, 'reserved': 10, 'empty': 1.
                               exNetModuleHwVer 1.3.6.1.4.1.66.1.3.2.2.1.1.3 integer read-only
The hardware configuration of the module or hub. For model 6311, 6312, and 6313 board types, the type of Network Interface provided with the board is indicated by the following values (0-3 apply to ExpressNet Hubs; 7 is returned for Concentrator modules): 0 = AUI 1 = 10BASE2 2 = 10BASE-T 3 = FOIRL 7 = no interface
                               exNetModuleStatus 1.3.6.1.4.1.66.1.3.2.2.1.1.4 integer read-only
The operational status of the module. If the status is selfTestFail(3), the exNetModuleSelfTestResult will give more detailed information about the module's condition. Enumeration: 'selfTestFail': 3, 'ok': 1, 'noComms': 2.
                               exNetModuleReset 1.3.6.1.4.1.66.1.3.2.2.1.1.5 integer read-write
The reset state of the module. Writing a 2 will reset the module's control logic, without changing the current configuration. Writing a 3 will reset the module to the initial factory default configuration. Enumeration: 'reset': 2, 'resetToDefault': 3, 'noReset': 1.
                               exNetModulePartStatus 1.3.6.1.4.1.66.1.3.2.2.1.1.6 integer read-write
Tells whether the module is partitioned or enabled. Writing a 2 will partition the module and 1 will enable the module. Enumeration: 'partition': 2, 'enabled': 1.
                               exNetModuleNmCntlStatus 1.3.6.1.4.1.66.1.3.2.2.1.1.7 integer read-only
Tells whether the module is under network management control. DAVID ExpressNet Concentrators always return nmControl(2), since all modules are always under network management control. Enumeration: 'notNmControl': 1, 'nmControl': 2.
                               exNetModulePsStatus 1.3.6.1.4.1.66.1.3.2.2.1.1.8 integer read-only
The status of the module's power supply. Enumeration: 'fail': 2, 'ok': 1.
                               exNetModuleFrmsRxOk 1.3.6.1.4.1.66.1.3.2.2.1.1.9 counter read-only
A count of frames that are successfully received by the module. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received.
                               exNetModuleOctetsRxOk 1.3.6.1.4.1.66.1.3.2.2.1.1.10 counter read-only
A count of data and padding octets in frames that are successfully received by the module. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received.
                               exNetModuleColls 1.3.6.1.4.1.66.1.3.2.2.1.1.13 counter read-only
Total collisions involving an incoming packet on any link or the backplane connector in the module. This counter increments once for each collision involving an incoming packet on any port, no matter how many ports are involved.
                               exNetModuleTooLongErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.14 counter read-only
A count of frames that are received by the module and exceed the maximum permitted frame size.
                               exNetModuleRuntErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.15 counter read-only
Number of frames received by the module that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes (512 bits). Runts are commonly collision fragments, and as such do not necessarily indicate a problem in the network. Runts are also called 'short frames.'
                               exNetModuleAlignErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.16 counter read-only
Number of frames received by the module that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the frame check sequence check, but are not counted as FCS errors.)
                               exNetModuleFcsErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.17 counter read-only
A count of frames received by the module that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. FCS errors are sometimes called CRC errors.
                               exNetModuleLateCollErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.18 counter read-only
A module count of the late collisions on all of the module's ports. The late collision counter for a port is incremented whenever a collision is detected on the port later than 512 bit times into the transmitted packet. Late collisions are not included in the collision count.
                               exNetModuleName 1.3.6.1.4.1.66.1.3.2.2.1.1.40 displaystring read-write
A descriptive string that can be used by a network administrator to name the module.
                               exNetModuleJabbers 1.3.6.1.4.1.66.1.3.2.2.1.1.41 counter read-only
A count of the number of times that the jabber function had to be invoked because a frame received from one of this module's ports exceeded 5 msec in duration.
                               exNetModuleSfdErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.42 counter read-only
Amount of activity from this module's ports where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity problem.)
                               exNetModuleAutoPartitions 1.3.6.1.4.1.66.1.3.2.2.1.1.43 counter read-only
Indicates how often ports on this module have been automatically partitioned by the module repeater function.
                               exNetModuleOosBitRate 1.3.6.1.4.1.66.1.3.2.2.1.1.44 counter read-only
Number of times that frames have been received from ports on this module with the transmission frequency (data rate) badly out of spec. This counter is incremented when the frequency of a received frame is so far out of spec that the packet has been corrupted within the relay. The spec allows deviations of +/- 100 parts per million (ppm). The DAVID ExpressNet Concentrators can handle greater deviations than this, depending on frame length.
                               exNetModuleLinkErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.45 counter read-only
This composite counter includes jabbers, auto-partitions, and start-frame delimiter errors.
                               exNetModuleFrameErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.46 counter read-only
This composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
                               exNetModuleFragErrors 1.3.6.1.4.1.66.1.3.2.2.1.1.47 counter read-only
Fragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on the module. Fragments indicate an external noise hit (a problem on the network). Fragments are also known as 'pygmies.'
                               exNetModulePortConfig 1.3.6.1.4.1.66.1.3.2.2.1.1.48 integer read-write
Compresses the configuration of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x) = 0 for disabled port and f(x) = exp(2,x-1) for enabled port.
                               exNetModuleLinkStatConfig 1.3.6.1.4.1.66.1.3.2.2.1.1.49 integer read-write
Compresses the link status configuration of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x) = 0 for port with link status disabled and f(x) = exp(2,x-1) for port with link status enabled.
                               exNetModuleResetTimeStamp 1.3.6.1.4.1.66.1.3.2.2.1.1.50 gauge read-only
The value of sysUpTime at the point that the module repeater state machine was last reset.
                               exNetModuleLinkStatus 1.3.6.1.4.1.66.1.3.2.2.1.1.51 integer read-only
Compresses the link status of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x) = 0 for port with link status test passed (link active) and f(x) = exp(2,x-1) for port with link status test failed (link inactive). For ports with link status test disabled, zero is returned. For example, if link status is active on all ports, the value returned is zero. If link status for ports 3 and 7 is inactive and the rest of the ports have active link status, the value returned is (2^(3-1) + 2^(7-1)) = (4 + 64) = 68.
                               exNetModuleFwVer 1.3.6.1.4.1.66.1.3.2.2.1.1.52 integer read-only
The firmware revision of the GAP processor on the module.
                               exNetModuleFwFeaturePkg 1.3.6.1.4.1.66.1.3.2.2.1.1.53 integer read-only
The feature package associated with the GAP processor on the module.
                               exNetModuleSelfTestResult 1.3.6.1.4.1.66.1.3.2.2.1.1.54 integer read-only
The self-test result value returned by the GAP processor on the module. Zero indicates that the module passed all tests. Bits set in the result indicate error conditions, as follows: Bit number Error encountered 0 ROM failure 1 CPU failure 2 RAM failure 3 repeater module failure 4 reserved 5 internal power (-5v) failure 6 NI power fuse (+12v) failure
                   exNetPort 1.3.6.1.4.1.66.1.3.2.3
                       exNetPortTable 1.3.6.1.4.1.66.1.3.2.3.1 no-access
A list of port entries. The number of entries is given by knowing the number of occupied slots in the exNetSlotConfigTable and the number of ports that are on an exNetModuleType.
                           exNetPortEntry 1.3.6.1.4.1.66.1.3.2.3.1.1 no-access
A port entry containing objects at the port level for a particular port.
                               exNetPortModuleIndex 1.3.6.1.4.1.66.1.3.2.3.1.1.1 integer read-only
A unique value for each module. Its value ranges between 1 and exNetChassisCapacity.
                               exNetPortIndex 1.3.6.1.4.1.66.1.3.2.3.1.1.2 integer read-only
A unique value for each port. Its value ranges between 1 and the value of exNetBoardNumOfPorts for this module.
                               exNetPortLinkStatus 1.3.6.1.4.1.66.1.3.2.3.1.1.3 integer read-only
For 10BASE-T ports: this is the link integrity test defined by the 10BASE-T standard. If link status test is enabled, this flag indicates whether the link is active or inactive. There are several reasons for an inactive link: . PC or workstation connected to the MAU has been turned off . disrupted link (e.g., wiring problem) . TP-MAU on the end of the link is missing, dead, or powered off . transmit and receive polarities are swapped For FOIRL ports: the link status is constantly tested; thus, this variable is always meaningful. A value of off(1) indicates a low-light condition (poor signal quality). The value on(2) indicates that signal quality on the link is ok. For AUI ports: the value other(3) is always returned since link status test does not apply. Enumeration: 'on': 2, 'other': 3, 'off': 1.
                               exNetPortPartStatus 1.3.6.1.4.1.66.1.3.2.3.1.1.4 integer read-write
Indicates whether the port is currently partitioned by the Concentrator's auto-partition protection. (The Concentrator automatically partitions a port if it is signalling continuous collision, or 32 consecutive collisions.) Writing a 1 will forcibly unpartition the port. Writing a 2 or a 3 is illegal. To enable or disable the port, use the exNetPortConfig variable. Enumeration: 'autoPartition': 3, 'partition': 2, 'enabled': 1.
                               exNetPortJabberStatus 1.3.6.1.4.1.66.1.3.2.3.1.1.5 integer read-only
Tells whether the DTE connected to the port is jabbering (receiving a frame longer than 5 msec in duration). Enumeration: 'ok': 1, 'jabbering': 2.
                               exNetPortFrmsRxOk 1.3.6.1.4.1.66.1.3.2.3.1.1.6 counter read-only
A count of frames that are successfully received by the port. This counter does not include frames received with frame-too- long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received.
                               exNetPortOctetsRxOk 1.3.6.1.4.1.66.1.3.2.3.1.1.7 counter read-only
A count of data and padding octets in frames that are successfully received by the port. This counter does not include frames received with frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received.
                               exNetPortColls 1.3.6.1.4.1.66.1.3.2.3.1.1.10 counter read-only
Number of times this port was involved in a collision with another port in the same Hub.
                               exNetPortTooLongErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.11 counter read-only
A count of frames that are received by the port and exceed the maximum permitted frame size.
                               exNetPortRuntErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.12 counter read-only
Number of frames received by the port that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes (512 bits). Runts are commonly collision fragments, and as such do not necessarily indicate a problem in the network. Runts are also called 'short frames.'
                               exNetPortAlignErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.13 counter read-only
Number of frames received by the port that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the frame check sequence check, but are not counted as FCS errors.)
                               exNetPortFcsErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.14 counter read-only
A count of frames received by the port that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. This counter is incremented when the frameCheckError status is detected. FCS errors are sometimes called CRC errors.
                               exNetPortLateCollErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.15 counter read-only
Number of times that a collision has been detected on this port later than 512 bit times into the transmitted packet. Late collisions are not included in the collision count.
                               exNetPortName 1.3.6.1.4.1.66.1.3.2.3.1.1.40 displaystring read-write
A descriptive string that can be used by a network administrator to name the port.
                               exNetPortJabbers 1.3.6.1.4.1.66.1.3.2.3.1.1.41 counter read-only
A count of the number of times that the jabber function had to be invoked because a frame received from this port exceeded 5 msec in duration.
                               exNetPortSfdErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.42 counter read-only
Amount of activity from this port where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity problem.)
                               exNetPortAutoPartitions 1.3.6.1.4.1.66.1.3.2.3.1.1.43 counter read-only
Indicates how often this port has been automatically partitioned by the module repeater function.
                               exNetPortOosBitRate 1.3.6.1.4.1.66.1.3.2.3.1.1.44 counter read-only
Number of times that frames have been received from this link with the transmission frequency (data rate) badly out of spec. This counter is incremented when the frequency of a received frame is so far out of spec that the packet has been corrupted within the relay. The spec allows deviations of +/- 100 parts per million (ppm). The DAVID ExpressNet Concentrators can handle greater deviations than this, depending on frame length.
                               exNetPortLinkErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.45 counter read-only
This composite counter includes jabbers, auto-partitions, late collisions, start-frame delimiter errors, and out-of-spec bit rate errors.
                               exNetPortFrameErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.46 counter read-only
This composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
                               exNetPortFragErrors 1.3.6.1.4.1.66.1.3.2.3.1.1.47 counter read-only
Fragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on this port. Fragments indicate an external noise hit (a problem on the network).
                               exNetPortType 1.3.6.1.4.1.66.1.3.2.3.1.1.48 integer read-only
The type of the port. Enumeration: 'tenBasefSync': 4, 'other': 1, 'repeater': 2, 'tenBasefAsync': 3.
                               exNetPortMauType 1.3.6.1.4.1.66.1.3.2.3.1.1.49 integer read-only
The type of the MAU attached to the port. Enumeration: 'tenBase2': 5, 'tenBaseT': 3, 'tenBase5': 2, 'fOIRL': 4, 'other': 1, 'tenBaseFA': 6.
                               exNetPortConfig 1.3.6.1.4.1.66.1.3.2.3.1.1.50 integer read-write
The administrative state of the port. If both transmit and receive are enabled, the port state is enabled. If both transmit and receive are disabled, the port state is disabled. Enumeration: 'disabled': 3, 'rxDisabled': 5, 'other': 1, 'enabled': 2, 'txDisabled': 4.
                               exNetPortLinkStatConfig 1.3.6.1.4.1.66.1.3.2.3.1.1.51 integer read-write
The administrative status of the link status test for this link. If both transmit and receive are enabled, the link status test is enabled. If both transmit and receive are disabled, the link status test is disabled. This variable applies only to ports with MauType = 10BASE-T. The value other(1) is returned for other MAU types. Enumeration: 'disabled': 3, 'rxDisabled': 5, 'other': 1, 'enabled': 2, 'txDisabled': 4.
                               exNetPortPolarity 1.3.6.1.4.1.66.1.3.2.3.1.1.52 integer read-write
The polarity of the port. Applies only to ports with MAU type 10BASE-T. The value other(1) is returned for other MAU types. Enumeration: 'positive': 2, 'txNegative': 4, 'other': 1, 'negative': 3, 'rxNegative': 5.
                               exNetPortTransmitTest 1.3.6.1.4.1.66.1.3.2.3.1.1.53 integer read-write
Whether or not transmit test is enabled on the link. Transmit test applies only to links of type 10BASE-T. The value other(1) is returned for other MAU types. THIS TEST CAN BE DISRUPTIVE TO THE NETWORK. Enumeration: 'disabled': 2, 'other': 1, 'enabled': 3.
                   exNetMgmt 1.3.6.1.4.1.66.1.3.2.4
                       exNetMgmtType 1.3.6.1.4.1.66.1.3.2.4.1 integer read-only
The DAVID ExpressNet Ethernet network management type. Enumeration: 'other': 1, 'tbd': 2.
                       exNetMgmtHwVer 1.3.6.1.4.1.66.1.3.2.4.2 integer read-only
The network management ICM hardware version number: 1=Rev. A, 2=Rev. B, etc.
                       exNetMgmtFwVer 1.3.6.1.4.1.66.1.3.2.4.3 integer read-only
The network management ICP firmware version.
                       exNetMgmtSwMajorVer 1.3.6.1.4.1.66.1.3.2.4.4 integer read-only
The network management major software version number, where the version number is of the form major.minor, e.g. 3.0. Refers to the ECP (External Communications Processor).
                       exNetMgmtSwMinorVer 1.3.6.1.4.1.66.1.3.2.4.5 integer read-only
The network management minor software version number, where the version number is of the form major.minor, e.g. 3.0. Refers to the ECP.
                       exNetMgmtStatus 1.3.6.1.4.1.66.1.3.2.4.6 integer read-only
Indicates that the network management is on line and operating. For the DAVID ExpressNet Concentrators, management status is always online(2). Enumeration: 'offline': 1, 'online': 2.
                       exNetMgmtMode 1.3.6.1.4.1.66.1.3.2.4.7 integer read-write
Indicates whether the network management is operating in primary or secondary mode. Presently, all DAVID ExpressNet Concentrators return primary(1). Enumeration: 'primary': 1, 'secondary': 2.
                       exNetMgmtReset 1.3.6.1.4.1.66.1.3.2.4.8 integer read-write
Network management reset status. Writing a 2 to this object will reset the network management (stop refreshing the watchdog timer) and restart. Enumeration: 'reset': 2, 'notReset': 1.
                       exNetMgmtRestart 1.3.6.1.4.1.66.1.3.2.4.9 integer read-write
Network management restart status. Writing a 2 to this object will restart the network management. This initializes all the counters, rereads the EEPROM data structure, and starts executing from the beginning of the code. Enumeration: 'notRestart': 1, 'restart': 2.
                       exNetMgmtIpAddr 1.3.6.1.4.1.66.1.3.2.4.10 ipaddress read-write
The network management's administrative IP address. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmtReset) is issued. At that time it becomes the operational IP address. The value of the CURRENT operational IP address can be obtained from the ipAdEntAddr entry in the ipAddrTable.
                       exNetMgmtNetMask 1.3.6.1.4.1.66.1.3.2.4.11 ipaddress read-write
The network management's administrative subnet mask. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmtReset) is issued. At that time it becomes the operational subnet mask. The value of the CURRENT operational subnet mask can be obtained from the ipAdEntNetMask entry in the ipAddrTable.
                       exNetMgmtDefaultGateway 1.3.6.1.4.1.66.1.3.2.4.12 ipaddress read-write
The network management's administrative default gateway IP address. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmtReset) is issued. At that time it becomes the operational default gateway IP address. The value of the CURRENT operational default gateway's IP address can be obtained from the ipRoutingTable.
                       exNetMgmtBaudRate 1.3.6.1.4.1.66.1.3.2.4.17 gauge read-only
Returns the baud rate in bits per second of the RS-232 port. Note: The Concentrators autobaud to match the device attached to the RS-232 port.
                       exNetMgmtLocation 1.3.6.1.4.1.66.1.3.2.4.19 displaystring read-write
This is an informational string that could be used to show the physical location (i.e., area) of the network management or Concentrator. This parameter is saved in non-volatile memory and will survive a reset. Note: This variable is aliased to the sysLocation variable in the MIB-II system group. Changing one will change the other. It is suggested that the system group variable be used whenever possible.
                       exNetMgmtTrapReceiverTable 1.3.6.1.4.1.66.1.3.2.4.20 no-access
This entity's Trap Receiver Table (10 entries).
                             exNetMgmtTrapReceiverEntry 1.3.6.1.4.1.66.1.3.2.4.20.1 no-access
A destination address and community string to a particular trap receiver.
                                 exNetMgmtTrapType 1.3.6.1.4.1.66.1.3.2.4.20.1.1 integer read-write
Setting this object to the value invalid(2) invalidates the corresponding entry in the exNetTrapReceiverTable. That is, it effectively disassociates the address identified with the entry by removing the entry from the table. Enumeration: 'other': 1, 'invalid': 2.
                                 exNetMgmtTrapReceiverAddr 1.3.6.1.4.1.66.1.3.2.4.20.1.2 ipaddress read-write
IP address for trap receiver.
                                 exNetMgmtTrapReceiverComm 1.3.6.1.4.1.66.1.3.2.4.20.1.3 octet string read-write
Community string used for traps.
                       exNetMgmtAuthTrap 1.3.6.1.4.1.66.1.3.2.4.21 integer read-write
Enable or disable the use of authentication error trap generation. Enumeration: 'enable': 2, 'disable': 1.