DAMOCLES-MIB: View SNMP OID List / Download MIB
VENDOR: HW GROUP S.R.O
Home | MIB: DAMOCLES-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
hwgroup | 1.3.6.1.4.1.21796 | |||
charonII | 1.3.6.1.4.1.21796.3 | |||
damocles | 1.3.6.1.4.1.21796.3.4 | |||
inpTable | 1.3.6.1.4.1.21796.3.4.1 | no-access |
A list of binary input entries. |
|
1.3.6.1.4.1.21796.3.4.1.1 | no-access |
An entry containing information applicable to a particular binary input. |
||
inpIndex | 1.3.6.1.4.1.21796.3.4.1.1.1 | positiveinteger | no-access |
The binary input index. |
inpState | 1.3.6.1.4.1.21796.3.4.1.1.2 | onoff | read-only |
The binary input state. |
inpName | 1.3.6.1.4.1.21796.3.4.1.1.3 | ioname | read-write |
The binary input name. |
inpAlarmSetup | 1.3.6.1.4.1.21796.3.4.1.1.4 | inputalarmsetup | read-write |
You can enable alarm for this binary input. Alarm can be inactive or active for ON/OFF state. |
inpAlarmState | 1.3.6.1.4.1.21796.3.4.1.1.5 | inputalarmstate | read-only |
The binary input alarm state. |
inpCounter | 1.3.6.1.4.1.21796.3.4.1.1.6 | nonnegativeinteger | read-write |
Number of pulses on this input. Entering edge is used to increment this counter. Only pulses longer than sampling interval are counted. |
outTable | 1.3.6.1.4.1.21796.3.4.2 | no-access |
A list of binary output entries. |
|
1.3.6.1.4.1.21796.3.4.2.1 | no-access |
An entry containing information applicable to a particular binary output. |
||
outIndex | 1.3.6.1.4.1.21796.3.4.2.1.1 | positiveinteger | no-access |
The binary output index. |
outState | 1.3.6.1.4.1.21796.3.4.2.1.2 | onoff | read-write |
The binary output state. 0 off(open), 1 on(close), 2 off if any alarm, 3 on if any alarm |
outName | 1.3.6.1.4.1.21796.3.4.2.1.3 | ioname | read-write |
The binary output name. |
outType | 1.3.6.1.4.1.21796.3.4.2.1.4 | outputtype | read-only |
The binary output type. 0 relay (off, on), 1 rts (-10,+10v), 2 dtr (0,10v) |
sensTable | 1.3.6.1.4.1.21796.3.4.3 | no-access |
A list of sensor table entries. The number of entries corresponds with number of detected sensors. |
|
1.3.6.1.4.1.21796.3.4.3.1 | no-access |
An entry containing information applicable to a particular sensor. |
||
sensIndex | 1.3.6.1.4.1.21796.3.4.3.1.1 | positiveinteger | no-access |
The sensor index. |
sensName | 1.3.6.1.4.1.21796.3.4.3.1.2 | sensorname | read-only |
The sensor name. |
sensState | 1.3.6.1.4.1.21796.3.4.3.1.4 | sensorstate | read-only |
The sensor state. |
sensString | 1.3.6.1.4.1.21796.3.4.3.1.5 | sensorstring | read-only |
The string representation of sensor value. |
sensValue | 1.3.6.1.4.1.21796.3.4.3.1.6 | sensorvalue | read-only |
The integer (decimal * 10) representation of sensor value. |
sensValueRaw | 1.3.6.1.4.1.21796.3.4.3.1.7 | sensorvalue | read-only |
The original raw value of sensor (it differs for each sensor type, especially 1-Wire sensors have different precisions). |
sensID | 1.3.6.1.4.1.21796.3.4.3.1.8 | sensorid | read-only |
The sensor ID. |
sensUnit | 1.3.6.1.4.1.21796.3.4.3.1.9 | unittype | read-only |
The sensor unit. |
tsAlarm | 1.3.6.1.4.1.21796.3.4.50 | |||
tsAlarmsPresent | 1.3.6.1.4.1.21796.3.4.50.1 | gauge32 | read-only |
The present number of active alarm conditions. |
tsAlarmTable | 1.3.6.1.4.1.21796.3.4.50.2 | no-access |
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with tsAlarmId equal to 1, and increments the value of tsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of tsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because tsAlarmId might have wrapped. The number of rows in the table at any given time is reflected by the value of tsAlarmsPresent. |
|
1.3.6.1.4.1.21796.3.4.50.2.1 | no-access |
An entry containing information applicable to a particular alarm. |
||
tsAlarmIdx | 1.3.6.1.4.1.21796.3.4.50.2.1.1 | positiveinteger | no-access |
An index to alarm table. |
tsAlarmId | 1.3.6.1.4.1.21796.3.4.50.2.1.2 | positiveinteger | read-only |
A unique identifier for an alarm condition. This value must remain constant. |
tsAlarmDescr | 1.3.6.1.4.1.21796.3.4.50.2.1.3 | integer | read-only |
Description of the alarm condition. Enumeration: 'maskStateAlarm': 3, 'temperatureOutOfRange': 2, 'inputStateAlarm': 1. |
tsAlarmSensName | 1.3.6.1.4.1.21796.3.4.50.2.1.4 | sensorname | read-only |
Name of sensor with alarm condition. |
tsAlarmTime | 1.3.6.1.4.1.21796.3.4.50.2.1.5 | timestamp | read-only |
The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tsAlarmTime shall equal 0. |
setup | 1.3.6.1.4.1.21796.3.4.99 | |||
sensSetup | 1.3.6.1.4.1.21796.3.4.99.1 | |||
unitType | 1.3.6.1.4.1.21796.3.4.99.1.1 | unittype | read-write |
Units for displayed values. All setup values are fixed in Celsius |
sensSetupTable | 1.3.6.1.4.1.21796.3.4.99.1.2 | no-access |
A list of sensor table setup entries. The number of entries corresponds with number of detected sensors. |
|
1.3.6.1.4.1.21796.3.4.99.1.2.1 | no-access |
An entry containing setup information for a particular sensor. |
||
sensSetupIndex | 1.3.6.1.4.1.21796.3.4.99.1.2.1.1 | positiveinteger | no-access |
The sensor setup table index. |
sensSetupName | 1.3.6.1.4.1.21796.3.4.99.1.2.1.2 | sensorname | read-write |
The sensor name. |
sensFlags | 1.3.6.1.4.1.21796.3.4.99.1.2.1.5 | sensorflags | read-write |
The behaviour of sensor - 0x01: range or level detection - 0x02: enable trap sending -- 0x04: output set (thermostat) - 0x08: sensor enabled - 0x10: enable SMS sending - 0x20: enable email sending. |
sensLimitMin | 1.3.6.1.4.1.21796.3.4.99.1.2.1.6 | sensorvalue | read-write |
The sensor low limit. |
sensLimitMax | 1.3.6.1.4.1.21796.3.4.99.1.2.1.7 | sensorvalue | read-write |
The sensor high limit. |
sensHysteresis | 1.3.6.1.4.1.21796.3.4.99.1.2.1.8 | sensorvalue | read-write |
The sensor hysteresis. |
inpChange | 1.3.6.1.4.1.21796.3.40.1 |
Input changed. |
||
sensStateChanged | 1.3.6.1.4.1.21796.3.40.2 |
Sensor n changed its state. |
||
tsTrapNewAlarm | 1.3.6.1.4.1.21796.3.40.3 |
This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for powerFailure. |
||
tsTrapAlarmEnd | 1.3.6.1.4.1.21796.3.40.4 |
This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms. |