ChrComIfOpticsOMS-SNK-MIB: View SNMP OID List / Download MIB

VENDOR: CHROMATIS NETWORKS INC.


 Home MIB: ChrComIfOpticsOMS-SNK-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 chrComIfOpticsOMS_SNKTable 1.3.6.1.4.1.3695.1.2.3.3 no-access
The OMS is managed only for the Ring side of the Metropolis Network (not for the Trib side).
     chrComIfOpticsOMS_SNKEntry 1.3.6.1.4.1.3695.1.2.3.3.1 no-access
         chrComIfOpticsOmsSnkNumOfPrecedingOPAs 1.3.6.1.4.1.3695.1.2.3.3.1.1 integer32 read-write
         chrComIfOpticsOmsSnkDWDMInputPower 1.3.6.1.4.1.3695.1.2.3.3.1.2 integer32 read-only
The aggregated optical power of all the DWDM input channels (without the 1310nm channel).
         chrComIfOpticsOmsSnkOPALOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.3 integer32 read-only
Threshold for the OMS-SNK DWDM Input Power , indicating Loss Of Optical DWDM Channels at the input to the Pre-OPA/in-line-OPA.
         chrComIfOpticsOmsSnkParamForOPALOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.4 integer32 read-write
Input parameter for calculating OMS-SNK LOOC Threshold (for pre-OPA/in-line-OPA only).
         chrComIfOpticsOmsSnkLOOPThr 1.3.6.1.4.1.3695.1.2.3.3.1.5 integer32 read-write
Threshold for the OMS-SNK DWDM Input Power indicating Loss Of Optical power in the DWDM band at the input to ADOM/OMDM.
         chrComIfOpticsOmsSnkReceived1310Power 1.3.6.1.4.1.3695.1.2.3.3.1.6 integer32 read-only
The optical power monitored on 1310 Receive point.
         chrComIfOpticsOmsSnkReceivedLambdaPower 1.3.6.1.4.1.3695.1.2.3.3.1.7 integer32 read-only
The optical power monitored on ADOM Lambda Receive point.
         chrComIfOpticsOmsSnkBackplaneAttenuatorLambda 1.3.6.1.4.1.3695.1.2.3.3.1.8 octet string read-write
Attenuation in dB. Zero when no backplane Attenuator exists.
         chrComIfOpticsOmsSnkBackplaneAttenuator1310 1.3.6.1.4.1.3695.1.2.3.3.1.9 integer32 read-write
Attenuation in dB. Zero when no backplane Attenuator exists.
         chrComIfOpticsOmsSnkParamForRxLambdaLOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.10 integer32 read-write
Input parameter for calculating OMS-SNK Received lambda LOOC threshold
         chrComIfOpticsOmsSnkRxLambdaLOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.11 integer32 read-only
Loop Threshold of OMS-SNK Received lambda power .
         chrComIfOpticsOmsSnkRx1310LOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.12 integer32 read-only
Loop threshold of OMS-SNK Received 1310 Power .
         chrComIfOpticsOmsSnkOchRRx1310LOOCThr 1.3.6.1.4.1.3695.1.2.3.3.1.13 integer32 read-write
A duplication of the OCH-R Received 1310 Looc threshold .
         chrComIfOpticsOmsSnkPreOPADWDMOutPower 1.3.6.1.4.1.3695.1.2.3.3.1.14 integer32 read-only
Total Optical Power Monitored at the output of a Pre-OPA.
         chrComIfOpticsOmsSnkPreOPAOutLOOPThr 1.3.6.1.4.1.3695.1.2.3.3.1.15 integer32 read-write
This is a threshold on the output power of the pre-OPA.
         chrComIfOpticsOmsSnkPreOPASafetyThr 1.3.6.1.4.1.3695.1.2.3.3.1.16 integer32 read-write
This is a threshold on the output power of the pre-OPA.
         chrComIfOpticsOmsSnkOPAModeOfOperation 1.3.6.1.4.1.3695.1.2.3.3.1.17 agcppc read-write
(Automatic Gain Control -AGC  Default) Automatic Pump Power Control  PPC
         chrComIfOpticsOmsSnkOPAExpectedGain 1.3.6.1.4.1.3695.1.2.3.3.1.18 integer32 read-write
Integer32, Units of 0.1 db. 0  35 db (10dB)
         chrComIfOpticsOmsSnkOPAActualGain 1.3.6.1.4.1.3695.1.2.3.3.1.19 integer32 read-only
Integer32, Units of 0.1 db. 0  35 db
         chrComIfOpticsOmsSnkOPAExpectedPumpPower 1.3.6.1.4.1.3695.1.2.3.3.1.20 integer32 read-write
The Desired EDFA pump power of pre-/in-line-OPA module.
         chrComIfOpticsOmsSnkOPAActualPumpPower 1.3.6.1.4.1.3695.1.2.3.3.1.21 integer32 read-only
The Actual EDFA pump power of pre-/in-line-OPA module.
         chrComIfOpticsOmsSnkOPAAPSDState 1.3.6.1.4.1.3695.1.2.3.3.1.22 apsdstate read-write
Controlling the Automatic Pump Shut Down (APSD) mode.
         chrComIfOpticsOmsSnkOPAPumpRestartAction 1.3.6.1.4.1.3695.1.2.3.3.1.23 truthvalue read-write
Enables remote operation which is equivalent to the restart push button of the pre-/in-line-OPA.
         chrComIfOpticsOmsSnkOPAPumpActivationStatus 1.3.6.1.4.1.3695.1.2.3.3.1.24 laseractivation read-only
Pre-/in-line-OPA Pump Laser ON/OFF Actual status.
         chrComIfOpticsOmsSnkOPAExpectedAttenuatorAttenuation 1.3.6.1.4.1.3695.1.2.3.3.1.25 integer32 read-write
The expected Attenuation of the attenuator at the output of the OPA
         chrComIfOpticsOmsSnkOPAActualAttenuatorAttenuation 1.3.6.1.4.1.3695.1.2.3.3.1.26 integer32 read-only
The actual Attenuation of the attenuator at the output of the OPA
         chrComIfOpticsOmsSnkOPAPumpTemperature 1.3.6.1.4.1.3695.1.2.3.3.1.27 unsigned32 read-only
The temperature of the module.
         chrComIfOpticsOmsSnkOPAPumpBiasCurrent 1.3.6.1.4.1.3695.1.2.3.3.1.28 integer32 read-only
         chrComIfOpticsAlarmVector 1.3.6.1.4.1.3695.1.2.3.3.1.29 unsigned32 read-only
         chrComIfOpticsAlarmSeverityProfileIndex 1.3.6.1.4.1.3695.1.2.3.3.1.30 unsigned32 read-write