CTRON-CHASSIS-MIB: View SNMP OID List / Download MIB
VENDOR: ENTERASYS NETWORKS INC.
Home | MIB: CTRON-CHASSIS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
ctChas | 1.3.6.1.4.1.52.4.3.1.1 | |||
ctChasFNB | 1.3.6.1.4.1.52.4.3.1.1.1 | integer | read-only |
Denotes the presence or absence of the FNB. Enumeration: 'absent': 1, 'present': 2. |
ctChasAlarmEna | 1.3.6.1.4.1.52.4.3.1.1.2 | integer | read-write |
Allow an audible alarm to be either enabled or dis- abled. Setting this object to disable(1) will prevent an audible alarm from being heard and will also stop the sound from a current audible alarm. Setting this object to enable(2) will allow an audible alarm to be heard and will also enable the sound from a current audible alarm, if it has previously been disabled. This object will read with the current setting. Enumeration: 'notSupported': 3, 'enable': 2, 'disable': 1. |
chassisAlarmState | 1.3.6.1.4.1.52.4.3.1.1.3 | integer | read-only |
Denotes the current condition of the power supply fault detection circuit. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition. Enumeration: 'chassisFaultCondition': 2, 'notSupported': 3, 'chassisNoFaultCondition': 1. |
ctEnviron | 1.3.6.1.4.1.52.4.3.1.2 | |||
ctChasPowerTable | 1.3.6.1.4.1.52.4.3.1.2.1 | no-access |
A list of power supply entries. |
|
1.3.6.1.4.1.52.4.3.1.2.1.1 | no-access |
An entry in the powerTable providing objects for a power supply. |
||
ctChasPowerSupplyNum | 1.3.6.1.4.1.52.4.3.1.2.1.1.1 | integer | read-only |
Denotes the power supply. |
ctChasPowerSupplyState | 1.3.6.1.4.1.52.4.3.1.2.1.1.2 | integer | read-only |
Denotes the power supply's state. Enumeration: 'infoNotAvailable': 1, 'installedAndNotOperating': 4, 'notInstalled': 2, 'installedAndOperating': 3. |
ctChasPowerSupplyType | 1.3.6.1.4.1.52.4.3.1.2.1.1.3 | integer | read-only |
Denotes the power supply type. Enumeration: 'highOutput': 4, 'dc-dc': 2, 'notSupported': 3, 'ac-dc': 1. |
ctChasPowerSupplyRedundancy | 1.3.6.1.4.1.52.4.3.1.2.1.1.4 | integer | read-only |
Denotes whether or not the power supply is redundant. Enumeration: 'notSupported': 3, 'notRedundant': 2, 'redundant': 1. |
ctFanModule | 1.3.6.1.4.1.52.4.3.1.3 | |||
ctChasFanModuleTable | 1.3.6.1.4.1.52.4.3.1.3.1 | no-access |
A list of fan module entries. |
|
1.3.6.1.4.1.52.4.3.1.3.1.1 | no-access |
An entry in the fan module Table providing objects for a fan module. |
||
ctChasFanModuleNum | 1.3.6.1.4.1.52.4.3.1.3.1.1.1 | integer | read-only |
Denotes the Fan module that may have failed. |
ctChasFanModuleState | 1.3.6.1.4.1.52.4.3.1.3.1.1.2 | integer | read-only |
Denotes the fan modules state. Enumeration: 'infoNotAvailable': 1, 'installedAndNotOperating': 4, 'notInstalled': 2, 'installedAndOperating': 3. |