CTMMIB: View SNMP OID List / Download MIB

VENDOR: LAST MILE GEAR


 Home MIB: CTMMIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lastmilegear 1.3.6.1.4.1.25868
             mibObjects 1.3.6.1.4.1.25868.1
                 version 1.3.6.1.4.1.25868.1.1 octet string read-only
Version of Web GUI - Version of Web GUI Interface currently running on CTM
                 site 1.3.6.1.4.1.25868.1.2 octet string read-only
Site Name - Site name as stored on CTM
                 lastIP 1.3.6.1.4.1.25868.1.3 octet string read-only
Last IP Address Login - Last IP address captured at Login Attempt
                 lastTime 1.3.6.1.4.1.25868.1.4 octet string read-only
Last Time Login - Last time of Login attempt
                 nSats 1.3.6.1.4.1.25868.1.5 integer read-only
Number Satellites in View - Number of Satellites in view of GPS Receiver Antenna being used for timing calculations
                 pwrP 1.3.6.1.4.1.25868.1.6 integer read-only
Master Primary Power - Master ?1? = Power OK, ?0? = Power Off or Low
                 pwrS 1.3.6.1.4.1.25868.1.7 integer read-only
Master Secondary Power - Master ?1? = Power OK, ?0? = Power Off or Low
                 cbTrip 1.3.6.1.4.1.25868.1.8 octet string read-only
Master Circuit Breaker Trip Bit Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
                 tempC 1.3.6.1.4.1.25868.1.9 integer read-only
Master Temperature
                 voltsM1 1.3.6.1.4.1.25868.1.10 integer read-only
Master Primary Power In Voltage - In Tenths of a Volt
                 voltsM2 1.3.6.1.4.1.25868.1.11 integer read-only
Master Secondary Power In Voltage - In Tenths of a Volt
                 portOnM 1.3.6.1.4.1.25868.1.12 octet string read-only
Master Ports ON Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
                 portSyncM 1.3.6.1.4.1.25868.1.13 octet string read-only
Master Ports Sync Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
                 portPwrM1 1.3.6.1.4.1.25868.1.14 integer read-only
Master Power Port 1 - (in tenths of a Watt) delivered on Port 1
                 portPwrM2 1.3.6.1.4.1.25868.1.15 integer read-only
Master Power Port 2 - (in tenths of a Watt) delivered on Port 2
                 portPwrM3 1.3.6.1.4.1.25868.1.16 integer read-only
Master Power Port 3 - (in tenths of a Watt) delivered on Port 3
                 portPwrM4 1.3.6.1.4.1.25868.1.17 integer read-only
Master Power Port 4 - (in tenths of a Watt) delivered on Port 4
                 portPwrM5 1.3.6.1.4.1.25868.1.18 integer read-only
Master Power Port 5 - (in tenths of a Watt) delivered on Port 5
                 portPwrM6 1.3.6.1.4.1.25868.1.19 integer read-only
Master Power Port 6 - (in tenths of a Watt) delivered on Port 6
                 portPwrM7 1.3.6.1.4.1.25868.1.20 integer read-only
Master Power Port 7 - (in tenths of a Watt) delivered on Port 7
                 portPwrM8 1.3.6.1.4.1.25868.1.21 integer read-only
Master Power Port 8 - (in tenths of a Watt) delivered on Port 8
                 modeReqM 1.3.6.1.4.1.25868.1.39 octet string read-only
Master CTM2 Port Type Setting - Master ?00?=Type A (Canopy) ?10?=Type B (OFDM), ?01? = Type C (POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE 24V mode, CTM2 C Only) listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
                 trpCntGM1 1.3.6.1.4.1.25868.1.45 integer read-only
Master Auto Restart Count Port 1 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 1
                 trpCntGM2 1.3.6.1.4.1.25868.1.46 integer read-only
Master Auto Restart Count Port 2 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 2
                 trpCntGM3 1.3.6.1.4.1.25868.1.47 integer read-only
Master Auto Restart Count Port 3 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 3
                 trpCntGM4 1.3.6.1.4.1.25868.1.48 integer read-only
Master Auto Restart Count Port 4 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 4
                 trpCntGM5 1.3.6.1.4.1.25868.1.49 integer read-only
Master Auto Restart Count Port 5 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 5
                 trpCntGM6 1.3.6.1.4.1.25868.1.50 integer read-only
Master Auto Restart Count Port 6 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 6
                 trpCntGM7 1.3.6.1.4.1.25868.1.51 integer read-only
Master Auto Restart Count Port 7 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 7
                 trpCntGM8 1.3.6.1.4.1.25868.1.52 integer read-only
Master Auto Restart Count Port 8 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 8
                 trpCntBM1 1.3.6.1.4.1.25868.1.53 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 1 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 1
                 trpCntBM2 1.3.6.1.4.1.25868.1.54 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 2 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 2
                 trpCntBM3 1.3.6.1.4.1.25868.1.55 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 3 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 3
                 trpCntBM4 1.3.6.1.4.1.25868.1.56 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 4 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 4
                 trpCntBM5 1.3.6.1.4.1.25868.1.57 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 5 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 5
                 trpCntBM6 1.3.6.1.4.1.25868.1.58 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 6 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 6
                 trpCntBM7 1.3.6.1.4.1.25868.1.59 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 7 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 7
                 trpCntBM8 1.3.6.1.4.1.25868.1.60 integer read-only
Master Ckt Breaker Auto Restart Fail Count Port 8 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 8
                   lostEthernetConnection 1.3.6.1.4.1.25868.10.0
Lost Ethernet Connection
                   masterPrimayPowerLost 1.3.6.1.4.1.25868.10.1
Master Primary Power Lost
                   masterSecondaryPowerLost 1.3.6.1.4.1.25868.10.2
Master Secondary Power Lost
                   gpsSignalLost 1.3.6.1.4.1.25868.10.3
GPS Signal Lost
                   masterTempatureError 1.3.6.1.4.1.25868.10.4
Master Temperature Error
                   masterCircuitBreakerTripCode 1.3.6.1.4.1.25868.10.5
Master Circuit Breaker Trip Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
                   loginFailedAttempt 1.3.6.1.4.1.25868.10.6
Login Failed Attempt
                   settingsChanged 1.3.6.1.4.1.25868.10.7
CTM Settings Changed
                   masterPrimaryPowerOK 1.3.6.1.4.1.25868.10.10
Master Primary Power OK
                   masterSecondaryPowerOK 1.3.6.1.4.1.25868.10.20
Master Secondary Power OK
                   gpsSignalOK 1.3.6.1.4.1.25868.10.30
GPS Signal OK
                   tempatureOK 1.3.6.1.4.1.25868.10.40
Temperature OK
                   circuitBreakersOK 1.3.6.1.4.1.25868.10.50
Circuit Breakers OK
                   masterAutoRestartCBCompletedOK 1.3.6.1.4.1.25868.10.52
Master Auto Restart CB Completed OK
                   loginOK 1.3.6.1.4.1.25868.10.60
Login OK
                   resetComplete 1.3.6.1.4.1.25868.10.80
Reset Complete
                   ethernetConnectionRestored 1.3.6.1.4.1.25868.10.99
Ethernet Connection Restored