CM-PROTECTION-MIB: View SNMP OID List / Download MIB
VENDOR: ADVA AG OPTICAL NETWORKING
Home | MIB: CM-PROTECTION-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
cmProtectionMIB | 1.3.6.1.4.1.2544.1.12.7 |
This module defines the Protection MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA Optical Networking. |
||
cmProtObjects | 1.3.6.1.4.1.2544.1.12.7.1 | |||
cmFacProtGroupTable | 1.3.6.1.4.1.2544.1.12.7.1.1 | no-access |
A list of entries corresponding to the Facility Protection Groups. Entries can be created/deleted in this table by management application action. |
|
1.3.6.1.4.1.2544.1.12.7.1.1.1 | no-access |
An entry containing information applicable to a particular Protection Group. |
||
cmFacProtGroupIndex | 1.3.6.1.4.1.2544.1.12.7.1.1.1.1 | integer32 | read-only |
Unique index value associated with the Facility Protection Group. |
cmFacProtGroupUserLabel | 1.3.6.1.4.1.2544.1.12.7.1.1.1.2 | displaystring | read-only |
User Label associated with the Facility Protection Group. |
cmFacProtGroupSwitchMode | 1.3.6.1.4.1.2544.1.12.7.1.1.1.3 | cmprotswitchmode | read-only |
Facility Protection Group's Protection Switch Mode. |
cmFacProtGroupRevertive | 1.3.6.1.4.1.2544.1.12.7.1.1.1.4 | truthvalue | read-only |
Whether the Facility Protection is revertive or not. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'. |
cmFacProtGroupWaitToRestore | 1.3.6.1.4.1.2544.1.12.7.1.1.1.5 | integer32 | read-only |
Time in minutes to wait before reverting to Working facility in case of cmFacProtGroupRevertive set to revertive. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'. |
cmFacProtGroupDirection | 1.3.6.1.4.1.2544.1.12.7.1.1.1.6 | cmprotswitchdirection | read-only |
Supported Protection Group Switch direction. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'. |
cmFacProtGroupWorkPort | 1.3.6.1.4.1.2544.1.12.7.1.1.1.7 | variablepointer | read-only |
Facility Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port. |
cmFacProtGroupProtPort | 1.3.6.1.4.1.2544.1.12.7.1.1.1.8 | variablepointer | read-only |
This object represents the PROTECT facility Network Element Port when cmFacProtGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the second active port. |
cmFacProtGroupStatus | 1.3.6.1.4.1.2544.1.12.7.1.1.1.9 | cmprotgroupstatus | read-only |
This object represents the PROTECTION group status. |
cmFacProtGroupAction | 1.3.6.1.4.1.2544.1.12.7.1.1.1.10 | cmprotswitchaction | read-write |
User initiated protection switch action. |
cmFacProtGroupStorageType | 1.3.6.1.4.1.2544.1.12.7.1.1.1.11 | storagetype | read-only |
The type of storage configured for this entry. |
cmFacProtGroupRowStatus | 1.3.6.1.4.1.2544.1.12.7.1.1.1.12 | rowstatus | read-only |
The status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of cmFacProtGroupRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with cmFacProtGroupRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The cmFacProtGroupRowStatus object may be modified if the associated instance of this object is equal to active(1). |
cmFacProtGroupMacAddress | 1.3.6.1.4.1.2544.1.12.7.1.1.1.13 | macaddress | read-only |
This object allows retrieval of the Mac Address of the PROTECTION group. |
cmFacProtUnitTable | 1.3.6.1.4.1.2544.1.12.7.1.2 | no-access |
A list of entries corresponding to the Facility Protection Units. |
|
1.3.6.1.4.1.2544.1.12.7.1.2.1 | no-access |
An entry containing information applicable to a particular Protection Unit. |
||
cmFacProtUnitIndex | 1.3.6.1.4.1.2544.1.12.7.1.2.1.1 | integer32 | read-only |
Unique index value associated with the Facility Protection Unit. |
cmFacProtUnitType | 1.3.6.1.4.1.2544.1.12.7.1.2.1.2 | cmprotunittype | read-only |
Facility Protection Unit's Type, i.e. whether working or protect. |
cmFacProtUnitState | 1.3.6.1.4.1.2544.1.12.7.1.2.1.3 | cmprotunitstate | read-only |
Facility Protection Unit's State, i.e. whether active or standby. |
cmFacProtUnitPort | 1.3.6.1.4.1.2544.1.12.7.1.2.1.4 | variablepointer | read-only |
Facility Protection Unit's points to a facility (port). This object represents the facility Network Element port. |
cmMSPGroupTable | 1.3.6.1.4.1.2544.1.12.7.1.3 | no-access |
A list of entries corresponding to the Multiplex Section Protection Groups. Entries can be created/deleted in this table by management application action. |
|
1.3.6.1.4.1.2544.1.12.7.1.3.1 | no-access |
An entry containing information applicable to a particular Protection Group. |
||
cmMSPGroupIndex | 1.3.6.1.4.1.2544.1.12.7.1.3.1.1 | integer32 | read-only |
Unique index value associated with the Multiplex Section Protection Group. |
cmMSPGroupUserLabel | 1.3.6.1.4.1.2544.1.12.7.1.3.1.2 | displaystring | read-only |
User Label associated with the Multiplex Section Protection Group. |
cmMSPGroupSwitchMode | 1.3.6.1.4.1.2544.1.12.7.1.3.1.3 | cmprotswitchmode | read-only |
Multiplex Section Protection Group's Protection Switch Mode. |
cmMSPGroupRevertive | 1.3.6.1.4.1.2544.1.12.7.1.3.1.4 | truthvalue | read-only |
Whether the Multiplex Section Protection is revertive or not. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'. |
cmMSPGroupWaitToRestore | 1.3.6.1.4.1.2544.1.12.7.1.3.1.5 | integer32 | read-only |
Time in minutes to wait before reverting to Working facility in case of cmMSPGroupRevertive set to revertive. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'. |
cmMSPGroupB2DEGTrigger | 1.3.6.1.4.1.2544.1.12.7.1.3.1.6 | truthvalue | read-only |
B2DEG is trigger of MSP or not. |
cmMSPGroupDirection | 1.3.6.1.4.1.2544.1.12.7.1.3.1.7 | cmprotswitchdirection | read-only |
Supported Protection Group Switch direction. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'. |
cmMSPGroupWorkPort | 1.3.6.1.4.1.2544.1.12.7.1.3.1.8 | variablepointer | read-only |
Multiplex Section Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port. |
cmMSPGroupProtPort | 1.3.6.1.4.1.2544.1.12.7.1.3.1.9 | variablepointer | read-only |
This object represents the PROTECT facility Network Element Port when cmMSPGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the second active port. |
cmMSPGroupStatus | 1.3.6.1.4.1.2544.1.12.7.1.3.1.10 | cmprotgroupstatus | read-only |
This object represents the PROTECTION group status. |
cmMSPGroupAction | 1.3.6.1.4.1.2544.1.12.7.1.3.1.11 | cmprotswitchaction | read-write |
User initiated protection switch action. |
cmMSPGroupStorageType | 1.3.6.1.4.1.2544.1.12.7.1.3.1.12 | storagetype | read-only |
The type of storage configured for this entry. |
cmMSPGroupRowStatus | 1.3.6.1.4.1.2544.1.12.7.1.3.1.13 | rowstatus | read-only |
The status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of cmMSPGroupRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with cmMSPGroupRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The cmMSPGroupRowStatus object may be modified if the associated instance of this object is equal to active(1). |
cmMSPGroupMacAddress | 1.3.6.1.4.1.2544.1.12.7.1.3.1.14 | macaddress | read-only |
This object allows retrieval of the Mac Address of the PROTECTION group. |
cmMSPUnitTable | 1.3.6.1.4.1.2544.1.12.7.1.4 | no-access |
A list of entries corresponding to the Multiplex Section Protection Units. |
|
1.3.6.1.4.1.2544.1.12.7.1.4.1 | no-access |
An entry containing information applicable to a particular Protection Unit. |
||
cmMSPUnitIndex | 1.3.6.1.4.1.2544.1.12.7.1.4.1.1 | integer32 | read-only |
Unique index value associated with the Multiplex Section Protection Unit. |
cmMSPUnitType | 1.3.6.1.4.1.2544.1.12.7.1.4.1.2 | cmprotunittype | read-only |
Multiplex Section Protection Unit's Type, i.e. whether working or protect. |
cmMSPUnitState | 1.3.6.1.4.1.2544.1.12.7.1.4.1.3 | cmprotunitstate | read-only |
Multiplex Section Protection Unit's State, i.e. whether active or standby. |
cmMSPUnitPort | 1.3.6.1.4.1.2544.1.12.7.1.4.1.4 | variablepointer | read-only |
Facility Protection Unit's points to a facility (port). This object represents the facility Network Element port. |
cmProtNotifications | 1.3.6.1.4.1.2544.1.12.7.2 | |||
cmProtConformance | 1.3.6.1.4.1.2544.1.12.7.3 | |||
cmProtCompliances | 1.3.6.1.4.1.2544.1.12.7.3.1 | |||
cmProtCompliance | 1.3.6.1.4.1.2544.1.12.7.3.1.1 |
Describes the requirements for conformance to the CM Prot group. |
||
cmProtGroups | 1.3.6.1.4.1.2544.1.12.7.3.2 | |||
cmProtObjectGroup | 1.3.6.1.4.1.2544.1.12.7.3.2.1 |
A collection of objects used to manage the Protection Object group. |
||
cmMSProtObjectGroup | 1.3.6.1.4.1.2544.1.12.7.3.2.2 |
A collection of objects used to manage the Multiplex Section Protection Object group. |