CISCO-VISM-CONN-STAT-MIB: View SNMP OID List / Download MIB

VENDOR: STRATACOM


 Home MIB: CISCO-VISM-CONN-STAT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
             vismChanCntGrp 1.3.6.1.4.1.351.110.5.5.3.3
                 vismChanCntGrpTable 1.3.6.1.4.1.351.110.5.5.3.3.1 no-access
vismChanCntGrpTable contains VISM channels counters.
                     vismChanCntGrpEntry 1.3.6.1.4.1.351.110.5.5.3.3.1.1 no-access
An entry for each voice channel.
                         vismCntChanNum 1.3.6.1.4.1.351.110.5.5.3.3.1.1.1 integer32 read-only
This object identifies the LCN(Logical Channel Number) on the VISM.
                         vismCntClrButton 1.3.6.1.4.1.351.110.5.5.3.3.1.1.10 integer read-only
This object is use to either reset counters or perform no action(do not clear counters). Enumeration: 'resetcounters': 2, 'noAction': 1.
                         vismChanAal2HecErrors 1.3.6.1.4.1.351.110.5.5.3.3.1.1.11 counter32 read-only
This object keep count of egress AAL2(ATM Adaptation layer 2) CPS(Common Part Sub-layer) PDU(Protocol Data Unit) dropped due to HEC(Header Error Control) error.
                         vismChanAal2CrcErrors 1.3.6.1.4.1.351.110.5.5.3.3.1.1.12 counter32 read-only
This object keeps track of egress AAL2 Type3 CPS PDUs dropped due to invalid CRC-10(Cyclic redundancy check) error. CRC validation is for Type 3 packets only. Type 1 packets are not subjected to CRC-10 error validation. Also this counter keeps track of CRC-10 errors for the Type 3 packets which are generated by the the datamover CPU only. It does not take into account of Type 3 packets generated by the DSP(Digital Signal Processing).
                         vismChanAal2OamLpbLostCells 1.3.6.1.4.1.351.110.5.5.3.3.1.1.13 counter32 read-only
This object keeps track of the number of OAM(Operation and management) loopback cells lost. OAM loopback cells are sent on a periodic basis (1 sec) on each PVC(Permanent Virtual Circuit) to monitor the health of the PVC.
                         vismChanAal2InvOsfCells 1.3.6.1.4.1.351.110.5.5.3.3.1.1.14 counter32 read-only
This object keeps track of the number AAL2 cells dropped due to invalid OSF (OffSet Field) in the egress direction.
                         vismChanAal2InvParCells 1.3.6.1.4.1.351.110.5.5.3.3.1.1.15 counter32 read-only
This object keeps track of the number of AAL2 cells dropped due to invalid Parity bit field in the egress direction.
                         vismChanAal2CpsSentPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.16 counter32 read-only
This object keeps track of the number of AAL2 CPS packets sent to the network.
                         vismChanAal2CpsRcvdPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.17 counter32 read-only
This object keeps track of AAL2 CPS packets received from the network. This does not include the packets which are counted as error packets.
                         vismChanAal2CpsInvCidPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.18 counter32 read-only
This object keeps track of AAL2 CPS packets dropped in the egress direction due to invalid CID(Channel Identifier). The CID may be considered as invalid if it is out of range or not configured.
                         vismChanAal2CpsInvUuiPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.19 counter32 read-only
This object keeps track of AAL2 CPS packets dropped in the egress direction due to invalid UUI (User-to-User Information) field.
                         vismChanAal2CpsInvLenPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.20 counter32 read-only
This object keeps track of AAL2 CPS packets dropped in the egress direction due to invalid length field.
                         vismChanAal5InvCpiPdus 1.3.6.1.4.1.351.110.5.5.3.3.1.1.21 counter32 read-only
This object counts the number of AAL5 PDUs dropped in the egress direction due to invalid CPI(Common Part Indicator) field in the AAL5 PDU trailer. This is applicable only to the PVCs configured as AAL5 PVCs (VoIP(Voice Over IP) PVCs or CCS(Common Channel Signaling) PVCs in the case of VoAAL2 application.
                         vismChanAal5OversizedSdusRcvdPdus 1.3.6.1.4.1.351.110.5.5.3.3.1.1.22 counter32 read-only
This object counts the number AAL5 PDUs dropped due to the SDU(Service Data Unit) size bigger than the configured value. This is applicable for AAL5 PVCs only.
                         vismChanAal5InvLenPdus 1.3.6.1.4.1.351.110.5.5.3.3.1.1.23 counter32 read-only
This object counts the number of AAL5 PDUs dropped due to the length violations. This is applicable to the CCS PVCs. The HDLC(High Level Data Link Control) frames should have a minimum frame size in order for the proper interpretation by the upper layer protocol.
                         vismChanAal5Crc32ErrorPdus 1.3.6.1.4.1.351.110.5.5.3.3.1.1.24 counter32 read-only
This object counts the number of AAL5 PDUs dropped in the egress direction due to CRC-32 errors detected by the SAR(Segmentation and Reassembly).
                         vismChanAal5ReassemTimerExpiryPdus 1.3.6.1.4.1.351.110.5.5.3.3.1.1.25 counter32 read-only
This object counts of AAL5 PDU reassembly timer expirations. The timers are maintained in the egress direction for building an AAL5 PDU from the cells.
                         vismChan24HrPeakXmtCellRate 1.3.6.1.4.1.351.110.5.5.3.3.1.1.26 counter32 read-only
This object counts the peak transmit cell rate (cells per second) for the channel since midnight with reference to node time; the peak cell rate counter gets reset to 0 every 24 hours at midnight. If the node time is changed, the counter will continue to gather data until the next time midnight is reached.
                         vismChanCurrentXmtCellRate 1.3.6.1.4.1.351.110.5.5.3.3.1.1.27 counter32 read-only
This object counts the current transmit cell rate (cells per second) for the channel.
                         vismChan24HrPeakRcvCellRate 1.3.6.1.4.1.351.110.5.5.3.3.1.1.28 counter32 read-only
This object counts the peak receive cell rate (cells per second) for the channel since midnight with reference to node time; the peak cell rate counter gets reset to 0 every 24 hours at midnight. If the node time is changed, the counter will continue to gather data until the next time midnight is reached.
                         vismChanCurrentRcvCellRate 1.3.6.1.4.1.351.110.5.5.3.3.1.1.29 counter32 read-only
This object counts the current receive cell rate (cells per second) for the channel.
                         vismChanAisSuppressCount 1.3.6.1.4.1.351.110.5.5.3.3.1.1.30 counter32 read-only
This object holds the number of times that ATM network alarms were successfully suppressed and prevented from propagating onto the TDM side for this PVC.
                         vismChanXmtAisCnts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.31 counter32 read-only
The number of instances that an ATM AIS alarm was transmitted.
                         vismChanRcvAisCnts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.32 counter32 read-only
The number of instances that an ATM AIS alarm was received.
                         vismChanXmtFerfCnts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.33 counter32 read-only
The number of instances that an ATM FERF alarm was transmitted.
                         vismChanRcvFerfCnts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.34 counter32 read-only
The number of instances that an ATM FERF alarm was received.
                         vismChanAal5PduSentPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.35 counter32 read-only
This object counts the number of AAL5 PDUs transmitted to the network. This is only applicable to the PVCs configured as AAL5 PVCs, VoIP (Voice Over IP) PVCs or CCS (Common Channel Signaling) PVCs in the case of VoAAL2 applications.
                         vismChanAal5PduRcvdPkts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.36 counter32 read-only
This object counts the number of AAL5 PDUs received from the network. This is only applicable to the PVCs configured as AAL5 PVCs, VoIP (Voice Over IP) PVCs or CCS (Common Channel Signaling) PVCs in the case of VoAAL2 applications.
                         vismChanAisDelayLeft 1.3.6.1.4.1.351.110.5.5.3.3.1.1.37 unsigned32 read-only
The real-time number of seconds remaining for the AIS delay timer after which the ATM alarm will be propagated to the TDM side. This object is tied to the vismChanAisDelayTime object in the CISCO-VISM-CONN-MIB. vismChanAisDelayTime will store the configurable AIS delay timer. The delay time left (vismChanAisDelayLeft) will be equal to the delay time in vismChanAisDelayTime until an AIS alarm is received at which point it starts to decrement and could go down to 0 and propagate the alarm to the TDM side.
                         vismChanOamLpbkTimeoutCnts 1.3.6.1.4.1.351.110.5.5.3.3.1.1.38 counter32 read-only
The number of instances that OAM loopback timeout alarm has occurred since the system was last re-initialized.
                         vismChanOamLpbkTimeoutDuration 1.3.6.1.4.1.351.110.5.5.3.3.1.1.39 unsigned32 read-only
The total duration of OAM loopback timeout alarms since the system was last re-initialized.
 ciscoVismConnStatMIB 1.3.6.1.4.1.351.150.89
The MIB module contain VISM channel counters information.
       ciscoVismConnStatMIBConformance 1.3.6.1.4.1.351.150.89.2
           ciscoVismConnStatMIBGroups 1.3.6.1.4.1.351.150.89.2.1
               ciscoVismConnStatGroup 1.3.6.1.4.1.351.150.89.2.1.1
The collection of objects which are used to represent VISM channel counter group.
               ciscoVismConnStatGroup1 1.3.6.1.4.1.351.150.89.2.1.2
The collection of objects which are used to represent VISM channel counter group.
               ciscoVismConnStatGroup2 1.3.6.1.4.1.351.150.89.2.1.3
The collection of objects which are used to represent VISM channel counter group.
               ciscoVismConnStatGroup3 1.3.6.1.4.1.351.150.89.2.1.4
The collection of objects which are used to represent VISM channel counter group.
           ciscoVismConnStatMIBCompliances 1.3.6.1.4.1.351.150.89.2.2
               ciscoVismConnStatCompliance 1.3.6.1.4.1.351.150.89.2.2.1
The compliance statement for objects related to VISM channel counters.
               ciscoVismConnStatCompliance1 1.3.6.1.4.1.351.150.89.2.2.2
The compliance statement for objects related to VISM channel counters.
               ciscoVismConnStatCompliance2 1.3.6.1.4.1.351.150.89.2.2.3
The compliance statement for objects related to VISM channel counters.
               ciscoVismConnStatCompliance3 1.3.6.1.4.1.351.150.89.2.2.4
The compliance statement for objects related to VISM channel counters.