CISCO-SIBU-STACKABLE-DUAL-SPEED-HUB-MIB: View SNMP OID List / Download MIB

VENDOR: CISCO


 Home MIB: CISCO-SIBU-STACKABLE-DUAL-SPEED-HUB-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoSibuStackableDualSpeedHubMIB 1.3.6.1.4.1.9.10.44
The MIB module that extends the REPEATER-MIB to manage CISCO low end stackable repeater products. For the purpose of this mib, a hub is a repeater group and stack is collection of one or more hubs interconnected via stack bus connectors.
       ciscoSibuStackableDualSpeedHubMIBObjects 1.3.6.1.4.1.9.10.44.1
           cssSystem 1.3.6.1.4.1.9.10.44.1.1
               cssSystemLinkTraps 1.3.6.1.4.1.9.10.44.1.1.1 integer read-write
Indicates whether the stack is permitted to generate linkUp/linkDown traps for both repeater port and switch module's port. The stack provides only a single global control of link traps in contrast to per interface control provided by IF-MIB. The value of all instances ifLinkUpDownTrapEnable is set to TRUE (FALSE) if this object is set to enabled (disabled). The object ifLinkUpDownTrapEnable is read-only. A linkUp/linkDown trap is generated whenever a port's link STATUS or administrative status changes. Enumeration: 'disabled': 2, 'enabled': 1.
           cssGroup 1.3.6.1.4.1.9.10.44.1.2
               cssGroupTable 1.3.6.1.4.1.9.10.44.1.2.1 no-access
A list of member hubs in the stack.
                   cssGroupEntry 1.3.6.1.4.1.9.10.44.1.2.1.1 no-access
Configuration parameters for an individual hub. An entry is created by default for the master unit in the stack. A entry is created (removed) when a hub is connected to (removed from) the stack.
                       cssGroupID 1.3.6.1.4.1.9.10.44.1.2.1.1.1 hubnumber read-only
The hub identifier of unit in a stack.
                       cssGroupType 1.3.6.1.4.1.9.10.44.1.2.1.1.2 integer read-only
The model type of the hub unit Enumeration: 'wsC412M': 3, 'cisco1538MDS': 1, 'wsC412': 4, 'wsC424': 6, 'wsC424M': 5, 'cisco1538UDS': 2.
                       cssGroupSerialNo 1.3.6.1.4.1.9.10.44.1.2.1.1.4 displaystring read-only
Serial number of the hardware.
                       cssGroupBoardRevision 1.3.6.1.4.1.9.10.44.1.2.1.1.5 integer32 read-only
Hardware version of the repeater board.
                       cssGroupAgentBootVersion 1.3.6.1.4.1.9.10.44.1.2.1.1.6 displaystring read-only
Returns the version number of the dual-speed hub BOOT software residing in flash. The format is 'V1.2.3'.
                       cssGroupAgentFirmwareVersion 1.3.6.1.4.1.9.10.44.1.2.1.1.7 displaystring read-only
Returns the version number of the dual-speed hub firmware residing in flash. The format is 'V1.2.3'.
                       cssGroupAgentStatus 1.3.6.1.4.1.9.10.44.1.2.1.1.8 integer read-only
Status of this hub agent. Each stack allows only one SNMP primary agent. notPresent(1): The hub does not have an agent. primary(2): The agent of this hub is a primary agent. backup(3) : The agent of this hub is a backup agent. Enumeration: 'notPresent': 1, 'backup': 3, 'primary': 2.
                       cssGroupAgentPhysAddress 1.3.6.1.4.1.9.10.44.1.2.1.1.9 physaddress read-only
MAC address of this hub's agent
                       cssGroupInternalPowerState 1.3.6.1.4.1.9.10.44.1.2.1.1.12 integer read-only
Indicates the state of the internal power supply. off : The internal power supply is off. on : The internal power supply is on. Enumeration: 'on': 2, 'off': 1.
                       cssGroupRedundantPowerState 1.3.6.1.4.1.9.10.44.1.2.1.1.13 integer read-only
Indicates the state of the external/backup power supply. off : the switch is not connected to a redundant power source. healthy : a redundant power source is connected to the switch and the power source is operating correctly. faulty : a redundant power source is connected to the switch but a failure exists in the power system. Enumeration: 'healthy': 2, 'faulty': 3, 'off': 1.
                       cssGroupReset 1.3.6.1.4.1.9.10.44.1.2.1.1.14 integer read-write
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test). Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read. Enumeration: 'reset': 2, 'noReset': 1.
                       cssGroupConfigDefaultReset 1.3.6.1.4.1.9.10.44.1.2.1.1.15 integer read-write
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test). All configuration parameters will revert to their factory default settings. Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read. Enumeration: 'reset': 2, 'noReset': 1.
                       cssGroupIsolatedState 1.3.6.1.4.1.9.10.44.1.2.1.1.16 integer read-write
Setting this object to isolated(1) causes this hub to be isolated from the back plane bus. Setting this object to attached(2) causes this hub to be attached to the back plane bus. Enumeration: 'attached': 2, 'isolated': 1.
           cssRepeaterPort 1.3.6.1.4.1.9.10.44.1.3
               cssRepeaterPortTable 1.3.6.1.4.1.9.10.44.1.3.1 no-access
The list of repeater port configurations on each hub unit.
                   cssRepeaterPortEntry 1.3.6.1.4.1.9.10.44.1.3.1.1 no-access
Configuration parameters for an individual repeater port on a hub. The value of rptrPortIndex also indicates the physical port number of the port in the hub. An entry is created for each repeater port in a hub when the hub is connected to the stack. The corresponding entries are removed when the hub is removed from the stack.
                       cssRepeaterPortName 1.3.6.1.4.1.9.10.44.1.3.1.1.1 displaystring read-write
A descriptive string of up to 20 characters used by the network administrator to name a port.
                       cssRepeaterPortControllerRevision 1.3.6.1.4.1.9.10.44.1.3.1.1.2 integer32 read-only
Returns the revision number of the port controller.
                       cssRepeaterPortSpeedAdmin 1.3.6.1.4.1.9.10.44.1.3.1.1.3 integer read-write
Set to tenMbps(1) to operate in 10Mbps speed mode. Set to oneHundredMbps(2) to operate in 100Mbps speed mode. Set to autoNegotiate(3) to allow the switch to negotiate with the other end of the connection. The actual operating speed of the port is given by cssRepeaterPortSpeedStatus. Enumeration: 'tenMbps': 1, 'oneHundredMbps': 2, 'autoNegotiate': 3.
                       cssRepeaterPortSpeedStatus 1.3.6.1.4.1.9.10.44.1.3.1.1.4 integer read-write
The operating speed of the port. Enumeration: 'tenMbps': 1, 'oneHundredMbps': 2.
                       cssRepeaterPortLinkStatus 1.3.6.1.4.1.9.10.44.1.3.1.1.5 integer read-only
The current port link status. Enumeration: 'link': 1, 'noLink': 2.
           cssSwitchPort 1.3.6.1.4.1.9.10.44.1.4
               cssSwitchPortTable 1.3.6.1.4.1.9.10.44.1.4.1 no-access
A list of switched ports on extension module on a each hub unit in the stack.
                   cssSwitchPortEntry 1.3.6.1.4.1.9.10.44.1.4.1.1 no-access
Configuration parameters for an individual switch module port. An entry is created for each switch port on a module is inserted into a hub in the stack. The corresponding entries are removed when the module is removed from the hub in the stack, or if the hub is removed from the stack.
                       cssSwitchPortModuleID 1.3.6.1.4.1.9.10.44.1.4.1.1.1 integer32 read-only
Unique ID number of a module unit in a hub as used in the command line interface.
                       cssSwitchPortPortID 1.3.6.1.4.1.9.10.44.1.4.1.1.2 integer32 read-only
The unique ID identifying a port on an extension module on a hub as used in the command line interface.
                       cssSwitchPortName 1.3.6.1.4.1.9.10.44.1.4.1.1.3 displaystring read-write
A descriptive string of up to 20 characters used by the network administrator to name a switch port.
                       cssSwitchPortType 1.3.6.1.4.1.9.10.44.1.4.1.1.4 integer read-only
Type of switch module in this hub. Enumeration: 'wsX4001': 1, 'wsX4002': 2.
                       cssSwitchPortControllerRevision 1.3.6.1.4.1.9.10.44.1.4.1.1.5 integer32 read-only
The revision number of the port controller.
                       cssSwitchPortState 1.3.6.1.4.1.9.10.44.1.4.1.1.6 integer read-write
Setting this object to enabled(1) enables the port. Setting this object to disabled(2) disables the port. Enumeration: 'disabled': 2, 'enabled': 1.
                       cssSwitchPortDuplexAdmin 1.3.6.1.4.1.9.10.44.1.4.1.1.7 integer read-write
Set to fullDuplex(1) to operate in full duplex mode: port will allow simultaneous transmit and receive which can double its bandwidth. Set to halfDuplex(2) to operate in normal mode. Set to autoNegotiate(3) to allow the switch to negotiate the duplex status with the other end of the connection. Enumeration: 'autoNegotiate': 3, 'fullDuplex': 1, 'halfDuplex': 2.
                       cssSwitchPortDuplexStatus 1.3.6.1.4.1.9.10.44.1.4.1.1.8 integer read-only
The operating duplex mode of the switched port. Enumeration: 'fullDuplex': 1, 'halfDuplex': 2.
                       cssSwitchPortSpeedAdmin 1.3.6.1.4.1.9.10.44.1.4.1.1.9 integer read-write
Set to tenMbps(1) to operate in 10Mbps speed mode. Set to oneHundredMbps(2) to operate in 100Mbps speed mode. Set to autoNegotiate(3) to allow the switch to negotiate the operating speed with the other end of the connection. If the value of object cssSwitchPortType is WS-X4002(2), this object will be read-only, because FX module only supports 100Mbps speed. Enumeration: 'tenMbps': 1, 'oneHundredMbps': 2, 'autoNegotiate': 3.
                       cssSwitchPortSpeedStatus 1.3.6.1.4.1.9.10.44.1.4.1.1.10 integer read-only
The operating speed of the switched port. Enumeration: 'tenMbps': 1, 'oneHundredMbps': 2.
                       cssSwitchPortLinkStatus 1.3.6.1.4.1.9.10.44.1.4.1.1.11 integer read-only
Indicates the link STATUS of switch port. Enumeration: 'link': 1, 'noLink': 2.
       ciscoSibuStackableDualSpeedHubNotifications 1.3.6.1.4.1.9.10.44.2
           ciscoSibuStackableDualSpeedHubNotificationsPrefix 1.3.6.1.4.1.9.10.44.2.0
               ciscoSibuStackableDualSpeedHubRptrPortLinkChange 1.3.6.1.4.1.9.10.44.2.0.1
This trap is generated whenever the value of cssRepeaterPortLinkStatus changes for a repeater port.
               ciscoSibuStackableDualSpeedHubSwitchPortLinkChange 1.3.6.1.4.1.9.10.44.2.0.2
This trap is generated whenever the value of cssSwitchPortLinkStatus changes for a switch port on an extension module.
       ciscoSibuStackableDualSpeedHubMIBComformance 1.3.6.1.4.1.9.10.44.3
           ciscoSibuStackableDualSpeedHubMIBCompliances 1.3.6.1.4.1.9.10.44.3.1
               ciscoSibuStackableDualSpeedHubCompliance 1.3.6.1.4.1.9.10.44.3.1.1
The compliance statement for the Cisco Stackable Dual-Speed Hub products.
           ciscoSibuStackableDualSpeedHubMIBGroups 1.3.6.1.4.1.9.10.44.3.2
               ciscoSibuStackableDualSpeedHubGroup 1.3.6.1.4.1.9.10.44.3.2.1
A collection of group objects for use with the Cisco Stackable Dual-Speed Hub products.
               ciscoSibuStackableDualSpeedHubRepeaterPortGroup 1.3.6.1.4.1.9.10.44.3.2.2
A collection of repeater port objects for use with the Cisco Stackable Dual-Speed Hub products.
               ciscoSibuStackableDualSpeedHubSwitchPortGroup 1.3.6.1.4.1.9.10.44.3.2.3
A collection of switch module port objects for use with the Cisco Stackable Dual-Speed Hub products.