Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoItpmMIB 1.3.6.1.4.1.9.9.379
The MIB for providing information related to monitoring SS7 links. This information can be used to manage the state of software used to collect all packets transported and received over a SS7 link. Abbreviations: MSU - Message Signalling Unit MTP - Message Transport Protocol SS7 - System No. 7 (SS7) Network
         ciscoItpmMIBNotifs 1.3.6.1.4.1.9.9.379.0
             ciscoItpMonitorCongestion 1.3.6.1.4.1.9.9.379.0.1
The notification generated when a connection enters or exits congestion state. The value of cItpmConnCongestion indicates new state.
             ciscoItpMonitorState 1.3.6.1.4.1.9.9.379.0.2
The notification generated when a connection changes states. The value of cItpmConnMonitorState indicates new state.
         ciscoItpmMIBObjects 1.3.6.1.4.1.9.9.379.1
             cItpmConn 1.3.6.1.4.1.9.9.379.1.1
                 cItpmConnTable 1.3.6.1.4.1.9.9.379.1.1.1 no-access
This table provides information on connections used to collect information on SS7 links. Information in this table can be used to customize connection parameters. In addition, this table provides measurements and status information for each connection.
                     cItpmConnTableEntry 1.3.6.1.4.1.9.9.379.1.1.1.1 no-access
An entry in the cItpmConnTable table.
                         cItpmConnPortNumber 1.3.6.1.4.1.9.9.379.1.1.1.1.1 inetportnumber no-access
The port number used to establish TCP connection.
                         cItpmConnKeepAlive 1.3.6.1.4.1.9.9.379.1.1.1.1.2 unsigned32 read-write
Specifies the keepalive time value in milliseconds. Keepalive packets are sent between the monitor and the remote server as a mechanism to ensure the TCP session is active and detect session failure in a timely manner. During periods of idle monitor traffic, the monitor will send a keepalive packet to the remote server at the specified interval. The monitor also expects to receive a keepalive packet from the remote server at the same interval. If the monitor does not receive a keepalive packet from the remote server in two times the keep alive value, the monitor will close the TCP session. The value of zero disables the keep alive processing.
                         cItpmConnMaxQDepth 1.3.6.1.4.1.9.9.379.1.1.1.1.3 unsigned32 read-write
The maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmit. This object defines the maximum number of TCP packets that may be queued for retransmit. Once the number of TCP packets on the queue reaches the value specified by this object, additional TCP packets will be dropped.
                         cItpmConnCongOnset 1.3.6.1.4.1.9.9.379.1.1.1.1.4 unsigned32 read-write
Threshold used to mark onset of congestion. When the cItpmConnQueueDepth object reaches value specified by this object the connection will considered congested. It will remain congested until the cItpmConnQueueDepth object drops below the value specified by the cItpmConnCongAbate object.
                         cItpmConnCongAbate 1.3.6.1.4.1.9.9.379.1.1.1.1.5 unsigned32 read-write
Threshold used to mark end of congestion. When the cItpmConnQueueDepth object drops below the value specified by this object the connection will exit congestion.
                         cItpmConnRcvWindowSize 1.3.6.1.4.1.9.9.379.1.1.1.1.6 unsigned32 read-write
The size of TCP receive window. This object defines the number of outstanding (unacknowledged) bytes that the ITP monitor can receive on TCP connection.
                         cItpmConnFastStart 1.3.6.1.4.1.9.9.379.1.1.1.1.7 truthvalue read-write
Defines the fast-start option for establishing TCP connectivity as follows. 'true' - FastStart is enabled. 'false' - FastStart is disabled. Normally, after the TCP session with the remote server is established, the monitor will not send MSUs from the monitored links to the server until the server responds to the first keepalive. This mechanism prevents the ITP from over-running the server until the TCP session and receive window sizes are fully established. Configuration of fast-start overrides this mechanism and allows the ITP to start sending MSUs to the server immediately after the TCP session is established. Caution should be used with the fast-start configuration as MSUs may be lost until the TCP session server and receive window sizes are fully established.
                         cItpmConnQueueDepth 1.3.6.1.4.1.9.9.379.1.1.1.1.8 gauge32 read-only
The number of packets queued for transmission. The maximum value is specified by the cItpmConnMaxQDepth object.
                         cItpmConnMonitorState 1.3.6.1.4.1.9.9.379.1.1.1.1.9 integer read-only
The state of the connection as follows. 'active' - connection is transmitting SS7 link traffic to server. 'inactive' - connection is not transmitting SS7 link traffic to server. Enumeration: 'active': 1, 'inactive': 2.
                         cItpmConnCongestion 1.3.6.1.4.1.9.9.379.1.1.1.1.10 truthvalue read-only
Congestion indicator for connection as follows. 'true' - connection is congested. 'false' - connection not congested. Congestion onset occurs when the cItpmConnQueueDepth object reaches the maximum allowed value specified by the cItpmConnMaxQDepth object. Congestion abate occurs when the cItpmConnQueueDepth object reaches the maximum allowed value specified by the cItpmConnMaxQDepth object.
                         cItpmConnCongCounts 1.3.6.1.4.1.9.9.379.1.1.1.1.11 counter32 read-only
The number of times the connection has entered congestion.
                 cItpmLinkTable 1.3.6.1.4.1.9.9.379.1.1.2 no-access
This table provides information and measurements on the monitored SS7 links per connection. This table shares the cItpmConnPortNumber index with the cItpmConnTable.
                     cItpmLinkTableEntry 1.3.6.1.4.1.9.9.379.1.1.2.1 no-access
An entry in the cItpmLinkTable table.
                         cItpmLinkNumber 1.3.6.1.4.1.9.9.379.1.1.2.1.1 unsigned32 no-access
This object specifies the secondary index for objects in the cItpmLinkTable table. A unique number is assigned to each link when it is assigned to a connection.
                         cItpmLinkDescription 1.3.6.1.4.1.9.9.379.1.1.2.1.2 snmpadminstring read-only
Brief customer defined description.
                         cItpmLinkSlotNumber 1.3.6.1.4.1.9.9.379.1.1.2.1.3 unsigned32 read-only
The slot number support interface used to collect SS7 link traffic.
                         cItpmLinkStatus 1.3.6.1.4.1.9.9.379.1.1.2.1.4 integer read-only
The state of the monitored SS7 Link as follows. 'active' - SS7 link is available for monitoring. 'inactive' - SS7 link is unavailable for monitoring. Enumeration: 'active': 1, 'inactive': 2.
                         cItpmLinkRcvdMsus 1.3.6.1.4.1.9.9.379.1.1.2.1.5 counter32 read-only
The number of MSUs received on SS7 Link.
                         cItpmLinkRcvdMsuDrops 1.3.6.1.4.1.9.9.379.1.1.2.1.6 counter32 read-only
The number of MSUs that were received on SS7 Link and were dropped due to congestion.
                         cItpmLinkRcvdMsuRate 1.3.6.1.4.1.9.9.379.1.1.2.1.7 gauge32 read-only
The number of MSUs received on SS7 Link per second.
                         cItpmLinkRcvdBitsRate 1.3.6.1.4.1.9.9.379.1.1.2.1.8 gauge32 read-only
The number of bits received on SS7 Link per second.
                         cItpmLinkSentMsus 1.3.6.1.4.1.9.9.379.1.1.2.1.9 counter32 read-only
The number of MSUs sent on SS7 Link.
                         cItpmLinkSentMsuDrops 1.3.6.1.4.1.9.9.379.1.1.2.1.10 counter32 read-only
The number of MSUs that were sent on SS7 Link and were dropped due to congestion.
                         cItpmLinkSentMsuRate 1.3.6.1.4.1.9.9.379.1.1.2.1.11 gauge32 read-only
The number of MSUs sent on SS7 Link per second.
                         cItpmLinkSentBitsRate 1.3.6.1.4.1.9.9.379.1.1.2.1.12 gauge32 read-only
The number of bits sent on SS7 Link per second.
             cItpmLink 1.3.6.1.4.1.9.9.379.1.2
             cItpmCongestionNotifEnabled 1.3.6.1.4.1.9.9.379.1.3 truthvalue read-write
The ITP monitor congestion States notification truth value. 'true' Indicates that cItpmCongestionNotifEnabled notification is to be generated when the state changes. That is, the notification generation is enabled. 'false' Indicates that cItpmCongestionNotifEnabled notification generation is disabled.
             cItpmMonitorStateNotifEnabled 1.3.6.1.4.1.9.9.379.1.4 truthvalue read-write
The ITP monitor state notification truth value. 'true' - Indicates that ciscoItpMonitorState notification is to be generated when the state of connection changes. That is, the notification generation is enabled. 'false' - Indicates that ciscoItpMonitorState notification generation is disabled.
         ciscoItpmMIBConform 1.3.6.1.4.1.9.9.379.2
             ciscoItpmMIBCompliances 1.3.6.1.4.1.9.9.379.2.1
                 ciscoItpmMIBCompliance 1.3.6.1.4.1.9.9.379.2.1.1
The compliance statement for entities which implement the CISCO-ITP-MONITOR-MIB.my MIB
                 ciscoItpmMIBComplianceRev1 1.3.6.1.4.1.9.9.379.2.1.2
The compliance statement for entities which implement the CISCO-ITP-MONITOR-MIB.my MIB
             ciscoItpmMIBGroups 1.3.6.1.4.1.9.9.379.2.2
                 ciscoItpmConnGroup 1.3.6.1.4.1.9.9.379.2.2.1
ITP Monitor connection group.
                 ciscoItpmLinkGroup 1.3.6.1.4.1.9.9.379.2.2.2
ITP Monitor SS7 Link group
                 ciscoItpmNotificationsGroup 1.3.6.1.4.1.9.9.379.2.2.3
ITP Monitor notification objects.
                 ciscoItpmConnGroupRev1 1.3.6.1.4.1.9.9.379.2.2.4
ITP Monitor connection group
                 ciscoItpmNotificationsGroupRev1 1.3.6.1.4.1.9.9.379.2.2.5
ITP Monitor notification objects.