Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoFcMulticastMIB 1.3.6.1.4.1.9.9.435
MIB module for monitoring and configuring Fibre Channel Multicast feature.
         ciscoFcMulticastNotifications 1.3.6.1.4.1.9.9.435.0
         ciscoFcMulticastMIBObjects 1.3.6.1.4.1.9.9.435.1
             cfmConfiguration 1.3.6.1.4.1.9.9.435.1.1
                 cfmMulticastRootTable 1.3.6.1.4.1.9.9.435.1.1.1 no-access
This table allows the users to configure and monitor the FC Multicast parameters on all the VSANs configured on the local switch. An entry is automatically created in this table if there is an entry in the fspfTable (defined in CISCO-FSPF-MIB) and fspfOperStatus (defined in CISCO-FSPF-MIB) for that entry is 'up'. An entry is automatically deleted from this table if either : a) the fspfOperStatus in the fspfTable entry for the corresponding VSAN changes to 'down'. or b) the fspfTable entry for the corresponding VSAN is deleted. Entries in this table can be created via cfmMulticastRootRowStatus only as the means to specify non-default parameter values for a VSAN either because the VSAN is suspended or fspfOperStatus (defined in CISCO-FSPF-MIB) for that VSAN is 'down' (VSAN state is indicated by object vsanOperState which is defined in CISCO-VSAN-MIB). So an entry in this table exists when one or both of these conditions holds: - one or more configuration parameters have non-default values for a VSAN which is either suspended or the fspfOperStatus for that VSAN is down. - the fspfOperStatus for VSAN is 'up'. This has a number of consequences: - an entry exists for a suspended VSAN whenever that VSAN has non-default parameters. - an entry cannot be created (via cfmMulticastRootRowStatus) for a VSAN with default parameters; instead, the agent creates/deletes an entry for a VSAN with default parameters according to whether the fspfOperStatus is 'up' or 'down'. - an entry can not be created via cfmMulticastRootRowStatus unless non-default parameter values are (simultaneously) configured for a VSAN whose fspfOperStatus is 'down'. - deleting an entry via cfmMulticastRootRowStatus when either the VSAN is suspended and configured with non-default values or the VSAN is active, is equivalent to resetting its parameters to their default values. If an entry is configured with default-values and the VSAN is in suspended state, then the entry would be deleted.
                     cfmMulticastRootEntry 1.3.6.1.4.1.9.9.435.1.1.1.1 no-access
This entry contains the multicase parameters on this VSAN.
                         cfmMulticastRootConfigMode 1.3.6.1.4.1.9.9.435.1.1.1.1.1 cfmmulticastrootmode read-only
The configured multicast root mode on this VSAN.
                         cfmMulticastRootOperMode 1.3.6.1.4.1.9.9.435.1.1.1.1.2 cfmmulticastrootmode read-only
The operational multicast root mode on this VSAN.
                         cfmMulticastRootDomainId 1.3.6.1.4.1.9.9.435.1.1.1.1.3 domainidorzero read-only
The domainID of the multicast root on this VSAN.
                         cfmMulticastRootRowStatus 1.3.6.1.4.1.9.9.435.1.1.1.1.4 rowstatus read-only
The status of conceptual row on this VSAN. This object can be used to create an entry only if either the corresponding VSAN is suspended or the fspfOperStatus is down. If the VSAN is either not-existent or fspfOperStatus is up, the create will fail.
         ciscoFcMulticaseConformance 1.3.6.1.4.1.9.9.435.2
             ciscoFcMulticastMIBCompliances 1.3.6.1.4.1.9.9.435.2.1
                 ciscoFcMulticastMIBCompliance 1.3.6.1.4.1.9.9.435.2.1.1
The compliance statement for entities which implement the CISCO-FC-MULTICAST-MIB.
             ciscoFcMulticastMIBGroups 1.3.6.1.4.1.9.9.435.2.2
                 cfmConfigurationGroup 1.3.6.1.4.1.9.9.435.2.2.1
A collection of objects for FC multicast configuration.