Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoEnvMonMIB 1.3.6.1.4.1.9.9.13
The MIB module to describe the status of the Environmental Monitor on those devices which support one.
       ciscoEnvMonObjects 1.3.6.1.4.1.9.9.13.1
           ciscoEnvMonPresent 1.3.6.1.4.1.9.9.13.1.1 integer read-only
The type of environmental monitor located in the chassis. An oldAgs environmental monitor card is identical to an ags environmental card except that it is not capable of supplying data, and hence no instance of the remaining objects in this MIB will be returned in response to an SNMP query. Note that only a firmware upgrade is required to convert an oldAgs into an ags card. Enumeration: 'ci': 4, 'oldAgs': 1, 'cat4000': 9, 'c7600': 12, 'ubr7200': 8, 'cat6000': 7, 'other': 14, 'osr7600': 11, 'cAccessMon': 6, 'c37xx': 13, 'ags': 2, 'c10000': 10, 'c7000': 3.
           ciscoEnvMonVoltageStatusTable 1.3.6.1.4.1.9.9.13.1.2 no-access
The table of voltage status maintained by the environmental monitor.
               ciscoEnvMonVoltageStatusEntry 1.3.6.1.4.1.9.9.13.1.2.1 no-access
An entry in the voltage status table, representing the status of the associated testpoint maintained by the environmental monitor.
                   ciscoEnvMonVoltageStatusIndex 1.3.6.1.4.1.9.9.13.1.2.1.1 integer32 no-access
Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
                   ciscoEnvMonVoltageStatusDescr 1.3.6.1.4.1.9.9.13.1.2.1.2 displaystring read-only
Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
                   ciscoEnvMonVoltageStatusValue 1.3.6.1.4.1.9.9.13.1.2.1.3 ciscosignedgauge read-only
The current measurement of the testpoint being instrumented.
                   ciscoEnvMonVoltageThresholdLow 1.3.6.1.4.1.9.9.13.1.2.1.4 integer32 read-only
The lowest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.
                   ciscoEnvMonVoltageThresholdHigh 1.3.6.1.4.1.9.9.13.1.2.1.5 integer32 read-only
The highest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.
                   ciscoEnvMonVoltageLastShutdown 1.3.6.1.4.1.9.9.13.1.2.1.6 integer32 read-only
The value of the associated instance of the object ciscoEnvMonVoltageStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.
                   ciscoEnvMonVoltageState 1.3.6.1.4.1.9.9.13.1.2.1.7 ciscoenvmonstate read-only
The current state of the testpoint being instrumented.
           ciscoEnvMonTemperatureStatusTable 1.3.6.1.4.1.9.9.13.1.3 no-access
The table of ambient temperature status maintained by the environmental monitor.
               ciscoEnvMonTemperatureStatusEntry 1.3.6.1.4.1.9.9.13.1.3.1 no-access
An entry in the ambient temperature status table, representing the status of the associated testpoint maintained by the environmental monitor.
                   ciscoEnvMonTemperatureStatusIndex 1.3.6.1.4.1.9.9.13.1.3.1.1 integer32 no-access
Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
                   ciscoEnvMonTemperatureStatusDescr 1.3.6.1.4.1.9.9.13.1.3.1.2 displaystring read-only
Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
                   ciscoEnvMonTemperatureStatusValue 1.3.6.1.4.1.9.9.13.1.3.1.3 gauge32 read-only
The current measurement of the testpoint being instrumented.
                   ciscoEnvMonTemperatureThreshold 1.3.6.1.4.1.9.9.13.1.3.1.4 integer32 read-only
The highest value that the associated instance of the object ciscoEnvMonTemperatureStatusValue may obtain before an emergency shutdown of the managed device is initiated.
                   ciscoEnvMonTemperatureLastShutdown 1.3.6.1.4.1.9.9.13.1.3.1.5 integer32 read-only
The value of the associated instance of the object ciscoEnvMonTemperatureStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.
                   ciscoEnvMonTemperatureState 1.3.6.1.4.1.9.9.13.1.3.1.6 ciscoenvmonstate read-only
The current state of the testpoint being instrumented.
           ciscoEnvMonFanStatusTable 1.3.6.1.4.1.9.9.13.1.4 no-access
The table of fan status maintained by the environmental monitor.
               ciscoEnvMonFanStatusEntry 1.3.6.1.4.1.9.9.13.1.4.1 no-access
An entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor.
                   ciscoEnvMonFanStatusIndex 1.3.6.1.4.1.9.9.13.1.4.1.1 integer32 no-access
Unique index for the fan being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
                   ciscoEnvMonFanStatusDescr 1.3.6.1.4.1.9.9.13.1.4.1.2 displaystring read-only
Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
                   ciscoEnvMonFanState 1.3.6.1.4.1.9.9.13.1.4.1.3 ciscoenvmonstate read-only
The current state of the fan being instrumented.
           ciscoEnvMonSupplyStatusTable 1.3.6.1.4.1.9.9.13.1.5 no-access
The table of power supply status maintained by the environmental monitor card.
               ciscoEnvMonSupplyStatusEntry 1.3.6.1.4.1.9.9.13.1.5.1 no-access
An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card.
                   ciscoEnvMonSupplyStatusIndex 1.3.6.1.4.1.9.9.13.1.5.1.1 integer32 no-access
Unique index for the power supply being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
                   ciscoEnvMonSupplyStatusDescr 1.3.6.1.4.1.9.9.13.1.5.1.2 displaystring read-only
Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
                   ciscoEnvMonSupplyState 1.3.6.1.4.1.9.9.13.1.5.1.3 ciscoenvmonstate read-only
The current state of the power supply being instrumented.
                   ciscoEnvMonSupplySource 1.3.6.1.4.1.9.9.13.1.5.1.4 integer read-only
The power supply source. unknown - Power supply source unknown ac - AC power supply dc - DC power supply externalPowerSupply - External power supply internalRedundant - Internal redundant power supply Enumeration: 'externalPowerSupply': 4, 'unknown': 1, 'ac': 2, 'internalRedundant': 5, 'dc': 3.
           ciscoEnvMonAlarmContacts 1.3.6.1.4.1.9.9.13.1.6 bits read-only
Each bit is set to reflect the respective alarm being set. The bit will be cleared when the respective alarm is cleared. Bits: 'criticalVisual': 2, 'minorVisual': 0, 'majorVisual': 1, 'majorAudible': 4, 'criticalAudible': 5, 'minorAudible': 3, 'input': 6.
       ciscoEnvMonMIBNotificationEnables 1.3.6.1.4.1.9.9.13.2
           ciscoEnvMonEnableShutdownNotification 1.3.6.1.4.1.9.9.13.2.1 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonShutdownNotification. A false value will prevent shutdown notifications from being generated by this system.
           ciscoEnvMonEnableVoltageNotification 1.3.6.1.4.1.9.9.13.2.2 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonVoltageNotification. A false value will prevent voltage notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.
           ciscoEnvMonEnableTemperatureNotification 1.3.6.1.4.1.9.9.13.2.3 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonTemperatureNotification. A false value prevents temperature notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.
           ciscoEnvMonEnableFanNotification 1.3.6.1.4.1.9.9.13.2.4 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonFanNotification. A false value prevents fan notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.
           ciscoEnvMonEnableRedundantSupplyNotification 1.3.6.1.4.1.9.9.13.2.5 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonRedundantSupplyNotification. A false value prevents redundant supply notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.
           ciscoEnvMonEnableStatChangeNotif 1.3.6.1.4.1.9.9.13.2.6 truthvalue read-write
This variable indicates whether the system produces the ciscoEnvMonVoltStatusChangeNotif, ciscoEnvMonTempStatusChangeNotif, ciscoEnvMonFanStatusChangeNotif and ciscoEnvMonSuppStatusChangeNotif. A false value will prevent these notifications from being generated by this system.
       ciscoEnvMonMIBNotificationPrefix 1.3.6.1.4.1.9.9.13.3
           ciscoEnvMonMIBNotifications 1.3.6.1.4.1.9.9.13.3.0
               ciscoEnvMonShutdownNotification 1.3.6.1.4.1.9.9.13.3.0.1
A ciscoEnvMonShutdownNotification is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown. This notification contains no objects so that it may be encoded and sent in the shortest amount of time possible. Even so, management applications should not rely on receiving such a notification as it may not be sent before the shutdown completes.
               ciscoEnvMonVoltageNotification 1.3.6.1.4.1.9.9.13.3.0.2
A ciscoEnvMonVoltageNotification is sent if the voltage measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonVoltStatusChangeNotif.
               ciscoEnvMonTemperatureNotification 1.3.6.1.4.1.9.9.13.3.0.3
A ciscoEnvMonTemperatureNotification is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a Notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonTempStatusChangeNotif.
               ciscoEnvMonFanNotification 1.3.6.1.4.1.9.9.13.3.0.4
A ciscoEnvMonFanNotification is sent if any one of the fans in the fan array (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonFanStatusChangeNotif.
               ciscoEnvMonRedundantSupplyNotification 1.3.6.1.4.1.9.9.13.3.0.5
A ciscoEnvMonRedundantSupplyNotification is sent if the redundant power supply (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonSuppStatusChangeNotif.
               ciscoEnvMonVoltStatusChangeNotif 1.3.6.1.4.1.9.9.13.3.0.6
A ciscoEnvMonVoltStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonVoltageState.
               ciscoEnvMonTempStatusChangeNotif 1.3.6.1.4.1.9.9.13.3.0.7
A ciscoEnvMonTempStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonTemperatureState.
               ciscoEnvMonFanStatusChangeNotif 1.3.6.1.4.1.9.9.13.3.0.8
A ciscoEnvMonFanStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonFanState.
               ciscoEnvMonSuppStatusChangeNotif 1.3.6.1.4.1.9.9.13.3.0.9
A ciscoEnvMonSupplyStatChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonSupplyState.
       ciscoEnvMonMIBConformance 1.3.6.1.4.1.9.9.13.4
           ciscoEnvMonMIBCompliances 1.3.6.1.4.1.9.9.13.4.1
               ciscoEnvMonMIBCompliance 1.3.6.1.4.1.9.9.13.4.1.1
The compliance statement for entities which implement the Cisco Environmental Monitor MIB. This is deprecated and new compliance ciscoEnvMonMIBComplianceRev1 is added.
               ciscoEnvMonMIBComplianceRev1 1.3.6.1.4.1.9.9.13.4.1.2
The compliance statement for entities which implement the Cisco Environmental Monitor MIB.
           ciscoEnvMonMIBGroups 1.3.6.1.4.1.9.9.13.4.2
               ciscoEnvMonMIBGroup 1.3.6.1.4.1.9.9.13.4.2.1
A collection of objects providing environmental monitoring capability to a cisco chassis. This group is deprecated in favour of ciscoEnvMonMIBGroupRev.
               ciscoEnvMonMIBGroupRev 1.3.6.1.4.1.9.9.13.4.2.2
A collection of objects providing environmental monitoring capability to a cisco chassis.
               ciscoEnvMonEnableStatChangeGroup 1.3.6.1.4.1.9.9.13.4.2.3
A collection of objects providing enabling/disabling of the status change notifications for environmental monitoring.
               ciscoEnvMonMIBNotifGroup 1.3.6.1.4.1.9.9.13.4.2.4
A notification group providing shutdown notification for environmental monitoring.
               ciscoEnvMonStatChangeNotifGroup 1.3.6.1.4.1.9.9.13.4.2.5
A collection of notifications providing the status change for environmental monitoring.
               ciscoEnvMonMIBMiscNotifGroup 1.3.6.1.4.1.9.9.13.4.2.6
A collection of various notifications for the enviromental monitoring mib module. The notifications the group and the group are both in deprecated state. The notifications in the group were deprecated in favour of notifications in ciscoEnvMonStatChangeNotifGroup.