CISCO-ENTITY-SENSOR-HISTORY-MIB: View SNMP OID List / Download MIB

VENDOR: CISCO


 Home MIB: CISCO-ENTITY-SENSOR-HISTORY-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoEntitySensorHistoryMIB 1.3.6.1.4.1.9.9.768
This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measurement either represents a measured value or a SMA (Simple Moving Average) value for a specified interval rate over a period of time. This MIB module defines two tables relating to sensor measured value, including: o ceshCollectionTable - contains data describing a collection of historic data for a sensor. o ceshCollectionIntervalTable - contains zero or more rows containing historic data for a sensor The figure below illustrates the relationship between these two tables. +----------------------------------------------+ | ceshCollectionTable | | +------------------------------------------+ | | | ceshCollectionEntry | | | | entPhysicalIndex = 3 | | | | ceshCollectionIntervalTime = 60 | | | | ceshCollectionIntervals = 60 | | | | ceshCollectionInvalidIntervals = 0 |-----+ | | ceshCollectionMaxIntervals = 60 | | | | | ceshCollectionElapsedTime = 20 | | | | | ceshCollectionAlgorithm = 3 | | | | +------------------------------------------+ | | | +------------------------------------------+ | | | | ceshCollectionEntry | | | | | entPhysicalIndex = 3 | | | | | ceshCollectionIntervalTime = 3660 | | | | | ceshCollectionIntervals = 2 |------------+ | | ceshCollectionInvalidIntervals = 0 | | | | | | ceshCollectionMaxIntervals = 60 | | | | | | ceshCollectionElapsedTime = 20 | | | | | | ceshCollectionAlgorithm = 4 | | | | | +------------------------------------------+ | | | +----------------------------------------------+ | | | | +----------------------------------------------+ | | | ceshCollectionIntervalTable | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | | ceshCollectionIntervalNumber = 1 | | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | | ceshCollectionIntervalTimeStamp = 1 | | | | | +------------------------------------------+ | | | | .................... <----+ | | skipped 58 entries <----+ | | .................... <----+ | | | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | ceshCollectionIntervalNumber = 60 | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | ceshCollectionIntervalTimeStamp = 60 | | | | +------------------------------------------+ | | | | | | +------------------------------------------+ | | | | ceshCollectionIntervalEntry | | | | | entPhysicalIndex = 3 |<-----------+ | | ceshCollectionIntervalTime = 3660 | | | | ceshCollectionIntervalNumber = 1 | | | | ceshCollectionIntervalSensorValue = 54 | | | | ceshCollectionIntervalTimeStamp = 60 | | | +------------------------------------------+ | +----------------------------------------------+ If the system samples a sensor every minute for one collection and every hour for another, then the ceshCollectionTable contains two entries describing the two collections.
         ciscoEntitySensorHistoryMIBObjects 1.3.6.1.4.1.9.9.768.0
             ceshCollectionTable 1.3.6.1.4.1.9.9.768.0.1 no-access
This table lists each collection of historic data maintained by the system for each supported sensor. This table has an expansion dependent relationship on the ceshCollectionIntervalTable, containing zero or more rows for each corresponding collection.
                 ceshCollectionEntry 1.3.6.1.4.1.9.9.768.0.1.1 no-access
Each entry in the ceshCollectionTable contains collection attributes describing the collection. For each supported sensor, the system creates a row for each prescribed collection. This creation process happens at startup and following the insertion of a FRU containing sensors. The system destroys a row when it destroys the corresponding row in the entPhysicalTable, which can happen as the result of the removal of the FRU containing the sensor.
                     ceshCollectionIntervalTime 1.3.6.1.4.1.9.9.768.0.1.1.1 unsigned32 no-access
This object indicates the length of the sampling interval for the collection.
                     ceshCollectionIntervals 1.3.6.1.4.1.9.9.768.0.1.1.2 gauge32 read-only
This object indicates the number of intervals for which data has been collected.
                     ceshCollectionInvalidIntervals 1.3.6.1.4.1.9.9.768.0.1.1.3 gauge32 read-only
This object indicates the number of intervals in the range of '0' to the value of the corresponding instance of ceshCollectionIntervals, for which no data is available. The value of this column will typically be '0', except in certain circumstances when some intervals are not available.
                     ceshCollectionMaxIntervals 1.3.6.1.4.1.9.9.768.0.1.1.4 unsigned32 read-only
This object indicates the maximum number of intervals maintained for the collection.
                     ceshCollectionElapsedTime 1.3.6.1.4.1.9.9.768.0.1.1.5 gauge32 read-only
This object indicates the time that has elapsed since the beginning of the current interval.
                     ceshCollectionAlgorithm 1.3.6.1.4.1.9.9.768.0.1.1.6 sensorhistorycollectionalgorithm read-only
This object indicates the algorithm used in collecting historic data from the corresponding sensor.
             ceshCollectionIntervalTable 1.3.6.1.4.1.9.9.768.0.2 no-access
This table contains the historic data for each collection maintained by the system. This table has an expansion dependent relationship on the ceshCollectionTable, containing zero or more rows for each corresponding collection.
                 ceshCollectionIntervalEntry 1.3.6.1.4.1.9.9.768.0.2.1 no-access
An entry describes the data collected for an interval. The system creates a row in the ceshCollectionIntervalTable after it has sampled a sample for a given collection. The maximum allowable entries for a collection should be less than or equal to the value specified by ceshCollectionMaxIntervals instance. Once number of entries is equal to ceshCollectionMaxIntervals, then the system destroys the lease recent row from the collection before creating a new one. An agent destroys all conceptual entries corresponding to a physical entity upon removal of the physical entity.
                     ceshCollectionIntervalNumber 1.3.6.1.4.1.9.9.768.0.2.1.1 unsigned32 no-access
This object indicates the interval number identifying the interval. The interval identified by the value '1' represents the most recent interval, and the interval identified by the value (n) represents the interval immediately preceding the interval identified by the value (n-1).
                     ceshCollectionIntervalSensorValue 1.3.6.1.4.1.9.9.768.0.2.1.2 entitysensorvalue read-only
This object indicates the sensor value for the corresponding physical entity during the interval. To correctly display or interpret this variable's value, you must also know the sensor's type, scale, and precision indicated by the corresponding entry in the entPhySensorTable (defined by the ENTITY-SENSOR-MIB) or entSensorValueTable (defined by the CISCO-ENTITY-SENSOR-MIB).
                     ceshCollectionIntervalTimeStamp 1.3.6.1.4.1.9.9.768.0.2.1.3 timestamp read-only
This object indicates the value of sysUpTime when the system sampled the corresponding sensor.
         ciscoEntitySensorHistoryMIBConform 1.3.6.1.4.1.9.9.768.1
             ciscoEntitySensorHistoryMIBCompliances 1.3.6.1.4.1.9.9.768.1.1
                 ciscoEntitySensorHistoryCompliance 1.3.6.1.4.1.9.9.768.1.1.1
Describes the requirements for conformance to the Entity Sensor History Collection MIB module.
             ciscoEntitySensorHistoryMIBGroups 1.3.6.1.4.1.9.9.768.1.2
                 ceshCollectionGroup 1.3.6.1.4.1.9.9.768.1.2.1
This group contains collection of attribute objects related to entity sensor history collection
                 ceshCollectionIntervalGroup 1.3.6.1.4.1.9.9.768.1.2.2
This group contains collection of interval objects related to entity sensor history collection